5
420 17 200 8 340 13 140 6 16 [.63] ANCHORS - BY INSTALLER A 263 [10] TO GATE PANEL IN OPEN POSITION 263 [10] TO GATE PANEL IN OPEN POSITION B B C C H D = NET GATE OPENING 110 4 90 4 610 PILE 24 30 1 1 DOUBLE-DELTA-07-13-11 Web: www.wallaceintl.com STANDARD DIMENSIONS DOUBLE DELTA GATE Description: Drawing No. Rev. Sheet: 5 - Project / Customer Name: - of Finish: Date: 90 Lowson Crescent, Winnipeg, Manitoba, Canada R3P 2H8 Phone: 1-866-300-1110 Fax: 1-204-284-1868 NOTE: DIMENSIONS ARE IN MILIMETERS. DIMENSIONS SHOWN IN [ ] ARE IN INCHES MODELS 85/85 & 95/95 ONLY MODELS 85/85 & 95/95 ONLY MODELS 85/85 & 95/95 ARE MEASURED TO THE OUTER EDGE OF OPTIONAL GATE REST PORTAL NOTE: GATE REST PORTAL ANCHORED TO ROADWAY SURFACE GATE REST PORTAL "U" DIMENSION IS THE MAXIMUM FOOTPRINT AFTER GATE INSTALLATION INCLUDING GATE PANEL TRAVEL GATE CONTROLLER * OPTIONAL: (MODELS 85/85 & 95/95 ONLY) (MODELS 85/85 & 95/95 ONLY) OPTIONAL: CENTER PANEL CATCH SHOE GATE CONTROLLER MODELS 95 & 120 ARE AVAILABLE IN 2000mm [78.7"] HEIGHTS ONLY U max. REFERENCE OF GATE PANEL IN OPEN POSITION MEASURED TO TOP GATE CONTROLLER FOR LEVELING DETAILS TO BOTTOM OF OF PILE SEE SHEET 3 REFERENCE OF GATE CONTROLLER H REFERENCE OF GATE PANEL IN OPEN POSITION * * Delta Model H A B C D U max. 30/30/150 1500 [59.1] 30/30/200 2000 [78.7] 30/30/250 2500 [98.4] 40/40/150 1500 [59.1] 40/40/200 2000 [78.7] 40/40/250 2500 [98.4] 50/50/150 1500 [59.1] 50/50/200 2000 [78.7] 50/50/250 2500 [98.4] 60/60/150 1500 [59.1] 60/60/200 2000 [78.7] 60/60/250 2500 [98.4] 70/70/150 1500 [59.1] 70/70/200 2000 [78.7] 70/70/250 2500 [98.4] 85/85/150 1500 [59.1] 85/85/200 2000 [78.7] 85/85/250 2500 [98.4] 95/95/200 2000 [78.7] 19120 [752.8] 2800 [110.2] 9560 [376.4] 18594 [732.0] 44040 [1733.9] 120/120/200 2000 [78.7] 24978 [983.4] 3726 [146.7] 24978 [983.4] 24452 [962.7] 55756 [2195.1] 12320 [485.0] 14920 [587.4] 2300 [90.6] 2300 [90.6] 2800 [110.2] 2800 [110.2] 9994 [393.5] 11794 [464.3] 6094 [239.9] 8194 [322.6] 1800 [70.1] 6620 [260.6] 8720 [343.3] 10520 [414.2] 1800 [70.1] 17320 681.9] 14394 [566.7] 16794 [661.2] 8660 [340.9] 17040 [670.9] 21240 [836.2] 25840 [1017.3] 29440 [1159.1] 35640 [1403.1] 40440 [1592.1]
Transcript
Page 1: U max. H D = NET GATE OPENING C B B C A - Sweets · h d = net gate opening 110 4 90 4 610 pile 24 30 1 ... size is equal to or greater than 8.5m [335] and the gate will remain in

42017

2008

34013

1406

16 [.63] ANCHORS- BY INSTALLER

A

263 [10] TO GATE PANEL IN OPEN

POSITION

263 [10] TO GATE PANEL IN OPEN

POSITION

BBC C

H

D = NET GATE OPENING

1104 90

4

610 PILE24

301

1 DOUBLE-DELTA-07-13-11Web: www.wallaceintl.com

STANDARD DIMENSIONS

DOUBLE DELTA GATEDescription:

Drawing No. Rev. Sheet:

5

-Project / Customer Name:

-

of

Finish: Date:90 Lowson Crescent, Winnipeg, Manitoba, Canada R3P 2H8Phone: 1-866-300-1110Fax: 1-204-284-1868

NOTE: DIMENSIONS ARE IN MILIMETERS. DIMENSIONS SHOWN IN [ ] ARE IN INCHES

MODELS 85/85 & 95/95 ONLY MODELS 85/85 & 95/95 ONLY

MODELS 85/85 & 95/95 ARE MEASURED TO THE OUTER EDGE OF OPTIONAL GATE REST PORTALNOTE:

GATE REST PORTALANCHORED TO ROADWAY SURFACE

GATE REST PORTAL

"U" DIMENSION IS THE MAXIMUM FOOTPRINT AFTER GATE INSTALLATION INCLUDING GATE PANEL TRAVEL

GATE CONTROLLER

*

OPTIONAL:

(MODELS 85/85 & 95/95 ONLY) (MODELS 85/85 & 95/95 ONLY)

OPTIONAL:CENTER PANEL CATCH SHOEGATE CONTROLLER

MODELS 95 & 120 ARE AVAILABLE IN 2000mm [78.7"] HEIGHTS ONLY

U max.REFERENCE OF GATE PANELIN OPEN POSITION

MEASURED TO TOP

GATE CONTROLLER

FOR LEVELING DETAILS

TO BOTTOM OF

OF PILE SEE SHEET 3

REFERENCE OF GATECONTROLLER

H

REFERENCE OF GATE PANELIN OPEN POSITION

**

Delta Model H A B C D U max.

30/30/150 1500 [59.1]30/30/200 2000 [78.7]30/30/250 2500 [98.4]40/40/150 1500 [59.1]40/40/200 2000 [78.7]40/40/250 2500 [98.4]50/50/150 1500 [59.1]50/50/200 2000 [78.7]50/50/250 2500 [98.4]60/60/150 1500 [59.1]60/60/200 2000 [78.7]60/60/250 2500 [98.4]70/70/150 1500 [59.1]70/70/200 2000 [78.7]70/70/250 2500 [98.4]85/85/150 1500 [59.1]85/85/200 2000 [78.7]85/85/250 2500 [98.4]95/95/200 2000 [78.7] 19120 [752.8] 2800 [110.2] 9560 [376.4] 18594 [732.0] 44040 [1733.9]

120/120/200 2000 [78.7] 24978 [983.4] 3726 [146.7] 24978 [983.4] 24452 [962.7] 55756 [2195.1]

12320 [485.0]

14920 [587.4]

2300 [90.6]

2300 [90.6]

2800 [110.2]

2800 [110.2]

9994 [393.5]

11794 [464.3]

6094 [239.9]

8194 [322.6]

1800 [70.1]6620 [260.6]

8720 [343.3]

10520 [414.2]

1800 [70.1]

17320 681.9]

14394 [566.7]

16794 [661.2]8660 [340.9]

17040 [670.9]

21240 [836.2]

25840 [1017.3]

29440 [1159.1]

35640 [1403.1]

40440 [1592.1]

Page 2: U max. H D = NET GATE OPENING C B B C A - Sweets · h d = net gate opening 110 4 90 4 610 pile 24 30 1 ... size is equal to or greater than 8.5m [335] and the gate will remain in

510 REINFORCING STEEL20

D - NET GATE OPENING

1004

26310

26310

REFERENCE OF DELTA PORTAL

FACTOR, PILE DEPTH SHOULD 1000 [40] BELOW FROST LINE

MINIMUM PILE DEPTHPILE IS CAST 30 [1.2] BELOW1200

THE HIGHEST ELEVATIONALONG GATE TRAVEL - SEE

SHEET 3 FOR MORE DETAILSAREAS WHERE FROST IS A

61024

6 pcs. 15M VERTICALS WITH510 [20] RINGS SPACED

AT 300 [12] DOUBLE RINGAT TOP

DETAIL B - CONCRETE PILE

- CONTROLLER CONDUITDETAIL D

DELTA GATE POWER SUPPLY

25 [1] CONDUIT240 VAC SINGLE PHASE - 15 AMP

(MODELS 85 & 95 ONLY)

GATE CONTROLLER

POWER / COMMUNICATION WIRING STUB-UPLOCATIONS USE FLEX TYPE CONDUIT

PUBLIC SIDE

MIN.

MIN.

VEHICLE DETECTION LOOP

VEHICLE DETECTION LOOP

25 [1] CONDUIT

DELTA GATE POWER SUPPLY208 / 240 VAC SINGLE PHASE - 15 AMP

PHOTOEYE CONDUIT - SEE SHEET 5

CONDUIT FROM CONTROLLER STUB-UP LOCATION305 [12] FOOTING x 2 m [79] DEPTH c/w 19 [3/4]

(MODELS 85 & 95 ONLY)

PEDESTAL TO GATE CONTROLLER - BY OTHERS

PEDESTAL TO GATE CONTROLLER - BY OTHERS25mm [1] CONDUIT KEYPAD / CARD READER

PEDESTAL / BOLLARD LOCATIONS

GATE CONTROLLERDETECTION LOOPS TO DELTA2 - 25mm [1] CONDUIT VEHICLE

PERIODS OF TIME.

NOTE

WILL REMAIN IN THE OPEN POSITION FOR EXTENDED ONLY IF GATE SIZE EXCEEDS 8.5m [335] AND GATEREAR GATE REST PORTAL IS RECOMMENDED

:

:

EXTENDED PERIODS OF TIME.WILL REMAIN IN THE OPEN POSITION FOR ONLY IF GATE SIZE EXCEEDS 8.5m [335] AND GATEREAR GATE REST PORTAL IS RECOMMENDED

OTHERWISE SPECIFIED AT TIME OF ORDER.PEDESTALS AND BOLLARDS ARE SUPPLIED BY OTHERS UNLESS ARE SHOWN FOR REFERENCE ONLY.SUGGESTED PEDESTAL AND BOLLARDS LOCATIONS

NOTE

NOTE:

25mm [1] CONDUIT KEYPAD / CARD READER

GATE CONTROLLER

SECURE SIDE

[20]500

B CC BA

1574000

[39]1000

[8] BOLLARD200

305 [12] BOLLARD FOOTING

= "D" NET OPENING + 200 [8]

SEE LOOP SIZING CHART BELOW

CL

[47]1200 [36]915

[47]1200 [36]915

to

1829 [72] - TRUCKS [48] - CARS1219

4000

BOLLARD

157

1829 [72] - TRUCKS [48] - CARS1200

CL

8 BOLLARD200

610SEE DETAIL B

[24] DELTA GATE PILE

305 BOLLARD FOOTING12

U max.

2 5

Description:

:teehS.veR.oN gniwarD

of

:etaD:hsiniF

Project / Customer Name:

Fax: 1-204-284-1868

SUGGESTED LOOP AND PEDESTAL LOCATIONS

DOUBLE-DELTA-07-13-11Web: www.wallaceintl.com

STANDARD DIMENSIONS

90 Lowson Crescent, Winnipeg, Manitoba, Canada R3P 2H8Phone: 1-866-300-1110

DOUBLE DELTA GATEDelta Model D - NET OPENING [ IN ] LW - LOOP WIDTH [ IN ]

30/30 6094 [240] 4572 [180]

40/40 9194 [323] 6401 [252]

50/50 9994 [394] 8230 [324]

60/60 11794 [464] 10058 [396]

70/70 14394 [567] 12802 [504]

85/85 16794 [661] 15240 [600]

95/95 18594 [732] 17069 [672]

120/120 24452 [962.7] 22869 [900]

Page 3: U max. H D = NET GATE OPENING C B B C A - Sweets · h d = net gate opening 110 4 90 4 610 pile 24 30 1 ... size is equal to or greater than 8.5m [335] and the gate will remain in

A

130 [5"] MEASURED FROM TOP OF PILE.AREA ALONG GATE PANEL TRAVEL MUSTBE CLEAR OF OBSTRUCTIONS TO ALLOWPROPER OPERATION OF GATE.GROUND COVER SHOULD BE RESILIANTENOUGH TO ALLOW CLEARING OF MUD,ICE, SNOW OR DERIS BUILD UP.

BC

U max.

BELOW HIGHEST ELEVATIONCAST PILES 30 [1.2"]

ALONG GATE TRAVEL (U max)

B C

REMOVAL OF ANY MUD , ICE, SNOW OR

AREA ADJACENT TO GATE SHOULD BECLEAR OF OBSTRUCTIONS ALLOWING

DEBRIS BUILD UP THAT MAY OCCUR.

PILES MUST BE CAST LEVEL

DOUBLE DELTA SLIDE GATE

INSTALLATION NOTESDescription:

Drawing No. Rev. Sheet:

of

Finish: Date:

-

DOUBLE-DELTA-07-13-11 3 5

Project / Customer Name:

Web: www.wallaceintl.com

-

90 Lowson Crescent, Winnipeg, Manitoba, Canada R3P 2H8Phone: 1-866-300-1110Fax: 1-204-284-1868

REFERENCE OF GATE PANEL IN OPEN POSITION

*** IMPORTANT NOTE ***

REFERENCE OF GATE PANEL IN OPEN POSITION

SURFACE SHOULD BE SUITABLEFOR SECURING CENTER CATCHSHOE USING 16 [5/8"] ANCHORS

Page 4: U max. H D = NET GATE OPENING C B B C A - Sweets · h d = net gate opening 110 4 90 4 610 pile 24 30 1 ... size is equal to or greater than 8.5m [335] and the gate will remain in

1506

4-2A

L

DETAIL 4-4 - OPTIONAL REAR REST SHOE

NOTE:

REAR GATE REST SHOE IS RECOMMENDED ONLY IF GATE SIZE IS EQUAL TO OR GREATER THAN 8.5M [335] AND THE GATEWILL REMAIN IN THE OPEN POSITION FOR EXTENDED PERIODS OF TIME

DETAIL 4-2B - MAIN BEAM ROLLER SET

MAIN BEAM ROLLER SET (X2)

CONTROLLER IS 90 [3.5]FROM GRADE

NOTE:

BOTTOM OF GATE

INCOMING POWER REQUIREMENTS, 240 VAC SINGLE PHASE, 15A

GATE CONTROLLER IS LOCATED ON THE SECURE SIDE OF GATE.

NOTES:

GATE FINISH:

- HOT DIPPED GALVANIZED FINISH FOR ALL STEEL COMPONENTS

- ALUMINUM GATE BEAMS - CLEAR ANODIZED FINISH

OPTIONAL:

POWDER COAT PAINT FINISH AVAILABLE - RAL COLOR NUMBER MUST BE SUPPLIED AT TIME OF ORDER.

36014

13340

50020

DETAIL 4-2A

4-2B

- CENTER CATCH SHOE DETAILSDETAIL 4-3

- GATE CONTROLLER DIMENSIONSDETAIL 4-1

- UPPER PANEL SUPPORT ROLLER

DETAIL 4-2 -PANEL ROLLERS

STANDARD / OPTIONAL COMPONENTS

Description:

:teehS.veR.oN gniwarD

of

:etaD:hsiniF

Project / Customer Name:

Fax: 1-204-284-1868

-

DOUBLE-DELTA-07-13-11Web: www.wallaceintl.com 4 5

90 Lowson Crescent, Winnipeg, Manitoba, Canada R3P 2H8Phone: 1-866-300-1110

DOUBLE DELTA GATE

PANEL SUPPORT ROLLER (x4)

DETAIL 4-5A - HERECLES PANEL INFILL DETAIL 4-5B - ATLAS PANEL INFILL

SERRATED ALUMINUMANTI-CLIMB EDGE

245

502

PICKETS EXTEND THRU GATETOP BEAM AND ARE MITRE CUTAT A 45 ANGLE

1837

1506

CL

CENTER CATCH SHOE IS ANCHORED TO ROADWAY USING 16 [5/8] WEDGE ANCHORS. ROADWAY SURFACE MUSTBE OF SUITABLE QUALITY FOR THEINSTALLATION OF ANCHORS.

CLOF ROADWAY

33013

16400

10250

60024

Page 5: U max. H D = NET GATE OPENING C B B C A - Sweets · h d = net gate opening 110 4 90 4 610 pile 24 30 1 ... size is equal to or greater than 8.5m [335] and the gate will remain in

13330

A

25 [1.0] SPARE

GATE CONTROLLER

13 [1/2"] FLEX TYPE PHOTOEYE CONDUIT

25 [1.0"] POWER CONDUIT

GATE CONTROLLER

25 [1.0"] COMMUNICATION CONDUIT

LEAVE 610 [24.0"] EXCESS FOR CONNECTIONS ABOVE GRADE.

ALL CONDUIT TO CONTROLLER LOCATION ARESTUBBED UP UNDER CONTROL ENCLOSURE.

ALL CONDUIT BELOW GRADE TO BE RIGID TYPE PVC

13340610

24

1707

CONDUIT LOCATION DETAIL

Description:

:teehS.veR.oN gniwarD

of

:etaD:hsiniF

Project / Customer Name:

Fax: 1-204-284-1868

-

-

DOUBLE-DELTA-07-13-11Web: www.wallaceintl.com

-

55

90 Lowson Crescent, Winnipeg, Manitoba, Canada R3P 2H8Phone: 1-866-300-1110

DELTA GATE

CONTROLLER PORTAL PHOTOEYE CONDUITDETAIL A:

13 [1/2"] FLEX TYPE PHOTOEYE CONDUIT FROM GATE CONTROLLER TO PHOTOEYE MOUNTED ON PORTAL - BY GATE INSTALLERS GROUT FLEX CONDUIT IN PLACE AFTER INSTALLATION IS COMPLETE

A

GROUT LEVELING GAP AFTER INSTALLATION

914 [36] BELOW GRADE

ABOVE GRADE305 [12]

IS COMPLETE. (ALL PORTALS)

13 [1/2"] FLEX TYPE PHOTOEYE CONDUITSTUBBED INTO CENTER OF GATECATCH PORTAL - SEE DETAIL A ABOVENO TRANSITION FROM RIGID TO FLEXCONDUIT SHOULD BE DONE BELOWGRADE

SEE SHEET 2 FOR MORE INFORMATION ON CONDUIT REQUIREMENTS AND LOCATIONS


Recommended