Ultrasound Simulations using REC and SAFT Presenter: Tony Podkowa November 13, 2012 Advisor: Dr José R. Sánchez Department of Electrical and Computer Engineering
Transcript
Page 1: Ultrasound Simulations using REC and SAFT Presenter: Tony Podkowa November 13, 2012 Advisor: Dr José R. Sánchez Department of Electrical and Computer Engineering.

Ultrasound Simulations using REC and SAFT

Presenter:Tony Podkowa

November 13, 2012

Advisor: Dr José R. SánchezDepartment of Electrical and Computer Engineering

Page 2: Ultrasound Simulations using REC and SAFT Presenter: Tony Podkowa November 13, 2012 Advisor: Dr José R. Sánchez Department of Electrical and Computer Engineering.

OutlineI. Introduction

II. Project Summary

III. Block Diagram

IV. Preliminary Work

V. Schedule

2

Page 3: Ultrasound Simulations using REC and SAFT Presenter: Tony Podkowa November 13, 2012 Advisor: Dr José R. Sánchez Department of Electrical and Computer Engineering.

OutlineI. Introduction

II. Project Summary

III. Block Diagram

IV. Preliminary Work

V. Schedule

3

Page 4: Ultrasound Simulations using REC and SAFT Presenter: Tony Podkowa November 13, 2012 Advisor: Dr José R. Sánchez Department of Electrical and Computer Engineering.

Introduction

Medical Applications Tumor detection Blood flow imaging Cardiac imaging

Piezoelectric Transducer Ultrasonic Pulses Tissue Density reflects Pulses

4

Page 5: Ultrasound Simulations using REC and SAFT Presenter: Tony Podkowa November 13, 2012 Advisor: Dr José R. Sánchez Department of Electrical and Computer Engineering.

OutlineI. Introduction

II. Project Summary

III. Block Diagram

IV. Preliminary Work

V. Schedule

5

Page 6: Ultrasound Simulations using REC and SAFT Presenter: Tony Podkowa November 13, 2012 Advisor: Dr José R. Sánchez Department of Electrical and Computer Engineering.

Project Summary

Specialized techniques improve image resolution and SNR.

Resolution Enhancement Compression (REC) Improves Axial Resolution and SNR

Synthetic Aperture Focusing Techniques (SAFT) Improve Lateral Resolution and SNR

Goal: To simulate the combination of both REC and SAFT in

an ultrasound system using the Matlab addon Field II.

6

Page 7: Ultrasound Simulations using REC and SAFT Presenter: Tony Podkowa November 13, 2012 Advisor: Dr José R. Sánchez Department of Electrical and Computer Engineering.

OutlineI. Introduction

II. Project Summary

III. Block Diagram

IV. Preliminary Work

V. Schedule

7

Page 8: Ultrasound Simulations using REC and SAFT Presenter: Tony Podkowa November 13, 2012 Advisor: Dr José R. Sánchez Department of Electrical and Computer Engineering.

System Block Diagram

REC Transducer SAFT

Vin(t)Vpc(t)

ImageRecon.

Image Output

Vlc(t)

Received Echo Signals

Beamformed Signals

8

Page 9: Ultrasound Simulations using REC and SAFT Presenter: Tony Podkowa November 13, 2012 Advisor: Dr José R. Sánchez Department of Electrical and Computer Engineering.

Resolution Enhancement Compression

Pulse Compression Technique Uses Convolution Equivalence Exchange the transducer impulse response a desired

response Increases bandwidth Better resolution

9

Page 10: Ultrasound Simulations using REC and SAFT Presenter: Tony Podkowa November 13, 2012 Advisor: Dr José R. Sánchez Department of Electrical and Computer Engineering.

Source:M. Oelze, “Bandwidth and Resolution Enhancement through Pulse Compression,” IEEE Trans. Ultrason., Ferroelec. and Freq. Control, vol. 54, pp. 768–781, Apr. 2007. 10

Page 11: Ultrasound Simulations using REC and SAFT Presenter: Tony Podkowa November 13, 2012 Advisor: Dr José R. Sánchez Department of Electrical and Computer Engineering.

REC Subsystem

WaveformGenerator

Vulc(f) Vpc(f)TukeyWindow

Vlc(f)

)(

)(

fH

fH

t

d

)(

)(

fH

fH

d

t

Vupc(f)

11

Page 12: Ultrasound Simulations using REC and SAFT Presenter: Tony Podkowa November 13, 2012 Advisor: Dr José R. Sánchez Department of Electrical and Computer Engineering.

System Block Diagram

REC Transducer SAFT

Vin(t)Vpc(t)

ImageRecon.

Image Output

Vlc(t)

Received Echo Signals

Beamformed Signals

12

Page 13: Ultrasound Simulations using REC and SAFT Presenter: Tony Podkowa November 13, 2012 Advisor: Dr José R. Sánchez Department of Electrical and Computer Engineering.

Transducer

Linear Array Transducer consisting of several elements

Capable of emitting and receiving ultrasonic pulses

Generates several signals to be processed to form an image.

S. I. Nikolov, Synthetic Aperture Tissue and Flow Ultrasound Imaging. PhD thesis, Technical University of Denmark, Aug. 2001.13

Page 14: Ultrasound Simulations using REC and SAFT Presenter: Tony Podkowa November 13, 2012 Advisor: Dr José R. Sánchez Department of Electrical and Computer Engineering.

Transducer Specifications

256 Elements 3 MHz Center Frequency 200 MHz Sampling Frequency 4 mm Element Height 0.26 mm Element Width 0.04 mm Element Kerf 20 mm Focus

Height

Width

Kerf

14

Page 15: Ultrasound Simulations using REC and SAFT Presenter: Tony Podkowa November 13, 2012 Advisor: Dr José R. Sánchez Department of Electrical and Computer Engineering.

System Block Diagram

REC Transducer SAFT

Received Echo Signals

Vin(t)Vpc(t)

ImageRecon.

Beamformed Signals

Image Output

Vlc(t)

15

Page 16: Ultrasound Simulations using REC and SAFT Presenter: Tony Podkowa November 13, 2012 Advisor: Dr José R. Sánchez Department of Electrical and Computer Engineering.

Synthetic Aperture Focusing Techniques

Electrically focuses signals to create an artificial aperture.

Uses different excitation schemes Three Variations:

Generic Synthetic Aperture Ultrasound (GSAU) Synthetic Transmit Aperture Ultrasound (STAU) Synthetic Receive Aperture Ultrasound (SRAU)

Results generated by delay and sum beamforming.

16

Page 17: Ultrasound Simulations using REC and SAFT Presenter: Tony Podkowa November 13, 2012 Advisor: Dr José R. Sánchez Department of Electrical and Computer Engineering.

GSAU

Transmit with one and receive with one.

Each transmit event generates a low resolution image.

Information needs to be delayed appropriately for each pixel before summing.

Gain in SNR:

c

xr

ippi

||2)(

ipx

pr

ix

ipip xrx

)(10log )SNR

SNR(10log GSNR 1010

0eN

17

Page 18: Ultrasound Simulations using REC and SAFT Presenter: Tony Podkowa November 13, 2012 Advisor: Dr José R. Sánchez Department of Electrical and Computer Engineering.

STAU

Transmit with one and receive with all.

Additional degree of freedom Gain in SNR:

c

xxr

jpippi

||||)(

ipx

pr

jpx

)(10log GSNR 210 eN

18

Page 19: Ultrasound Simulations using REC and SAFT Presenter: Tony Podkowa November 13, 2012 Advisor: Dr José R. Sánchez Department of Electrical and Computer Engineering.

SRAU

Transmit with all and receive with one.

Gain in SNR:

c

rxr

pippi

||||)(

ipx

pr)(10log GSNR 3

10 eN

19

Page 20: Ultrasound Simulations using REC and SAFT Presenter: Tony Podkowa November 13, 2012 Advisor: Dr José R. Sánchez Department of Electrical and Computer Engineering.

SAFT

Delay and SumBeamforming

Apodization

Image Scan Lines

Received Echo Signals

20

Page 21: Ultrasound Simulations using REC and SAFT Presenter: Tony Podkowa November 13, 2012 Advisor: Dr José R. Sánchez Department of Electrical and Computer Engineering.

Apodization

Spatial Windowing Used to shape the beam

profile Reweighting by apodization

coefficients Several different windowing

techniques can be studied Rectangular Triangular Raised Cosine

a1

a2

aN

21

Page 22: Ultrasound Simulations using REC and SAFT Presenter: Tony Podkowa November 13, 2012 Advisor: Dr José R. Sánchez Department of Electrical and Computer Engineering.

System Block Diagram

REC Transducer SAFT

Received Echo Signals

Vin(t)Vpc(t)

ImageRecon.

Beamformed Signals

Image Output

Vlc(t)

22

Page 23: Ultrasound Simulations using REC and SAFT Presenter: Tony Podkowa November 13, 2012 Advisor: Dr José R. Sánchez Department of Electrical and Computer Engineering.

Image Reconstruction Subsystem

WienerFilter

Envelope Detection

Logarithmic Compression

Limiter

Beamformed Signal Image

Scan Line

Vlc(t)

)(SNR|)(|

)()(

1-2

*

ffV

fVf

lc

lcREC

23

Page 24: Ultrasound Simulations using REC and SAFT Presenter: Tony Podkowa November 13, 2012 Advisor: Dr José R. Sánchez Department of Electrical and Computer Engineering.

OutlineI. Introduction

II. Project Summary

III. Block Diagram

IV. Preliminary Work

V. Schedule

24

Page 25: Ultrasound Simulations using REC and SAFT Presenter: Tony Podkowa November 13, 2012 Advisor: Dr José R. Sánchez Department of Electrical and Computer Engineering.

Preliminary Work

Image Reconstruction subsystem completed. STAU partially completed

Conventional pulsing instead of REC Individual low resolution images generated. Output image generated. Rectangular apodization 64 elements instead of 256

25

Page 26: Ultrasound Simulations using REC and SAFT Presenter: Tony Podkowa November 13, 2012 Advisor: Dr José R. Sánchez Department of Electrical and Computer Engineering.

Individual STAU Images

26

Page 27: Ultrasound Simulations using REC and SAFT Presenter: Tony Podkowa November 13, 2012 Advisor: Dr José R. Sánchez Department of Electrical and Computer Engineering.

Effect of Beamforming

27

Page 28: Ultrasound Simulations using REC and SAFT Presenter: Tony Podkowa November 13, 2012 Advisor: Dr José R. Sánchez Department of Electrical and Computer Engineering.

OutlineI. Introduction

II. Project Summary

III. Block Diagram

IV. Preliminary Work

V. Schedule

28

Page 29: Ultrasound Simulations using REC and SAFT Presenter: Tony Podkowa November 13, 2012 Advisor: Dr José R. Sánchez Department of Electrical and Computer Engineering.

Schedule

1/28 – 2/8: REC 2/11 – 2/22: GPGPU implementation of STAU 2/25 – 3/8: GSAU 3/11 – 3/29: SRAU 4/1 – 4/12: Prepare for Student Scholarship Expo 4/15 – 4/19: Expo 4/22 – 5/3: Write Final Report & Presentation

29

Page 30: Ultrasound Simulations using REC and SAFT Presenter: Tony Podkowa November 13, 2012 Advisor: Dr José R. Sánchez Department of Electrical and Computer Engineering.

Ultrasound Simulations using REC and SAFT

Presenter:Tony Podkowa

November 13, 2012

Advisor: Dr José R. SánchezDepartment of Electrical and Computer Engineering

Page 31: Ultrasound Simulations using REC and SAFT Presenter: Tony Podkowa November 13, 2012 Advisor: Dr José R. Sánchez Department of Electrical and Computer Engineering.

Generic Synthetic Aperture Ultrasound

Object

31

Page 32: Ultrasound Simulations using REC and SAFT Presenter: Tony Podkowa November 13, 2012 Advisor: Dr José R. Sánchez Department of Electrical and Computer Engineering.

Generic Synthetic Aperture Ultrasound

Object

32

Page 33: Ultrasound Simulations using REC and SAFT Presenter: Tony Podkowa November 13, 2012 Advisor: Dr José R. Sánchez Department of Electrical and Computer Engineering.

Matched Filter

ADCPre-

amplifierMatched

filter

Echo Signal

SAFTA Reconstructed image

A

33


Recommended