UMB-technology Universal-Measurement-Bus www.lufft.com
Transcript
Page 1: Umb E 2009 2010

UMB-technologyUniversal-Measurement-Bus

www.lufft.com

Page 2: Umb E 2009 2010

Advantages of UMB

• Compact design for real-time weather stations

• Easy to assemble

• Easy to install, easy commissioning

• one software-protocol for all devices

• one hardware-interface for all devices

• One industrial power supply (24VDC) for all devices; UMB modules and (heated) sensors

• All components for DIN-rail assembly with bus-connector

• Firmware-Update via RS232 or RS485

• one software-Tool for all sensors (commissioning and FAT test)

UMB-technology

Page 3: Umb E 2009 2010

WS600-UMB

Innovative method: R²S microwaves–doppler radar

Precipitation type (rain, snow) / precipitation intensity (mm/h)

Measurement of wind speed and wind direction

By ultrasonic sensors. Very precise, low start-up value, maintenance-free

Air pressure sensor

Measurement of air temperature and rel. humidity

Including ventilated/aspirated radiation shield

Data transmission and power supply in one cable

RS485-interface up to 1200m

Digital communication of data via open ASCII or UMB protocol

(SDI12 coming soon)

UMB sensors

Page 4: Umb E 2009 2010

R2S Microwaves-doppler radar principle = Present Weather Detector

24 GHz microwaves-dopplerradar measures precipitation type and precipitation intensity by correlation of drop size and drop speed

Examples of distribution on drop size and drop speed at different precipitation types

rain snow

UMB sensors

Page 5: Umb E 2009 2010

IRS31-UMB Intelligent Road Sensor

Road surface temperature, optionally two extra subsurface temperatures (e.g. -5cm and -30 cm)

Water film measurement up to 4mm by microwaves radar sensor - resolution: 0,01 mm- accuracy: 0,1 mm + 20%

Passive salt concentrations- and freeze point temperature measurement by measuring the conductivity dependent on water film height

Road condition detection dry, damp/humid, wet, ice, snow (critical), critical wetness

Digital data communication as standard protocol (Lufft-UMB-protocol)

Maintenance-friendly, exchangeable electronics

UMB sensors

Page 6: Umb E 2009 2010

Eutectical point

Each measurement of the freeze point temperature depends on salt concentration AND existing water film.

The more water on the surface the higher the salt concentration to bring down the freeze point. Vice versa, in case of declining roads, there is a high risk of oversalting the road.

In this case, the EUTECTICAL POINT is exceeded, the corresponding result is ice formation.

UMB sensors

Page 7: Umb E 2009 2010

ARS31-UMB Active Road sensor

Measurement of salt concentration and freeze point temperature by active cooling and heating of the sensor surface.

Maintenance-friendly, exchangeable electronics

digital data communication via standard protocol (Lufft-UMB-protocol)

Recommendation: A combination of passive IRS31-UMB and aktive ARS31-UMB.

UMB sensors

Page 8: Umb E 2009 2010

Quality paper / Test certificate

UMB sensors

With every road sensor:

manufacturers certificate

• water film measurement

• salt concentration

• temperature measurements

Page 9: Umb E 2009 2010

Comparison active/passive/non-invasive

comparison LUFFT IRS 31 – LUFFT ARS 31 - VAISALA DSC 111 – VAISALA DST 111

 Measurements IRS 31 ARS 31 DSC 111 DST 111

Salt concentration X      

Freeze point temperature X X    

Road surface temperature X   X

Ice percentage X   X

Friction X   X  

Waterfilm X   X

Snow Height (according to waterfilm) X   X

Precision certificate X X    

Depth temperature - 5 cm X      

Depth temperature - 30 cm X      

Forecast road conditions X    

Manufacturers certificate X X    

BAST-certificate X X    

Measurement principle Passive Active Passive Passive

Installation In-pavement Non-invasive

Page 10: Umb E 2009 2010

Recommendation active/passive/non-invasive?

Recommendation IR-Camera IRS31-UMB passive

combination

IRS31-UMB passive

ARS31-UMB active

Non invasive DRS111 DST111

Winter maintenance

*** **** **** ***

Maintenance and early warning

*** **** **** **

Maintenance on airports

** *** **** --

Maintenance on airports and early warning

** *** **** --

Traffic Control ** **** *** ****

Traffic Control and early warning

*** **** ** ***

Attention: The table describes road/runway conditions measurements only, indenpendent on other meteorological sensors (air temperature, rel. Humidity, precipitation)

Page 11: Umb E 2009 2010

R2S-UMB Radar precipitation sensor

UMB sensors

Innovative principle: R²S microwaves–doppler radar

Precipitation type (rain, snow, mixed rain, ice rain and hail) / Precipitation intensity (mm/h)

Maintenance-free sensor

Accumulation calculation (resolution 0,01mm / 0,1mm / 1mm)

Digital data communication with standardprotocol (Lufft-UMB-Protocol) and 2 digitale outputs

Page 12: Umb E 2009 2010

VS20-UMB visibility sensor

UMB sensors

Measurement principle: 45° forward scattering

Measures visibility precisely up to 2000m

Ideal for fog detection with traffic control systems

Analog output 4...20mA

Calibration device available (option)

Digital data communication with standard protocol (Lufft-UMB-protocol)

Page 13: Umb E 2009 2010

UMB-modules

UMB-module

ISOCON

ANACON

Which module with which sensor?

WS-UMB IRS31-UMB ARS31-UMB R2S-UMB VS20-UMB

Connection of all Lufft standard analog sensors

Page 14: Umb E 2009 2010

Differentiation:

• dry, damp, wet, snow

• snow height and snow distribution

• water film height

• friction risks

• influence of road conditions on traffic flow

In combination with IRS31/ARS31 minimisation of on-site checks

camera = „artificial eye on site“

UMB-camera

Page 15: Umb E 2009 2010

UMB-communication

LCOM - Lufft Communicator

Industrial PC with Windows CE

For communication there are the following interfaces: USB, GPRS-Modem (RS232), Partyline-Modem(RS232), UMB-Bus (RS485)

conversion of UMB-data into standard protocols:

TLS, NTCIP, TLS over IP with GPRS (Asfinag), DGT, MSSI (Asfinag)

configuration and measurement displays of the system via 7“ Display and touchscreen

Remote access to analyse the system and for firmwareupdates via modem

Page 16: Umb E 2009 2010

GPRS-Modem

UMB-communication

GPRS-Router/Modem for connection with UMB-system via RS232 interface

Connection of camera via Ethernet Interface

Page 17: Umb E 2009 2010

COM-Server

UMB-Kommunikation

Com-Server for connection of UMB-system via RS232 interface

Connection clients network via Ethernet interface

Page 18: Umb E 2009 2010

Example Communication

“All in One”road conditions measurements

Power supply

Mod

em

“All in One”WS-Family

Radio- or direct-connectionUMB-technology

= modular= extendable

= low power consumption

digital interface with UMB-protocol

digital interface with UMB-Protocol

UMB-communication

Page 19: Umb E 2009 2010

Construction example UMB-system

Example: Weather case (pole)

Consisting of

1x WS600-UMB (ISOCON)

1x IRS31-UMB (ISOCON)

1x ARS31-UMB (ISOCON)

1x door contact (ANACON)

Local data collector LCOM

(TLS-compatible)

UMB-system example

Page 20: Umb E 2009 2010

UMB Config-Software

• Features– Configuration of all UMB sensors– Measurement displays of all UMB sensors for test purposes– Data storage in text-file– Supports Firmware Updates for UMB-modules and connected sensors – Supports on-site calibrations

• Coming soon– Multilingual– Measurement display while another master polls (parallel, monitor-

function)

UMB-Config-Tool

Page 21: Umb E 2009 2010

Configuration of measurement set-up

• Basis

– Start via „Edit“, “Sensors”

– Then add the sensors from station,

one by one– Or you can use the „Autoscan“ button to

scan the sensors automatically

– Check the sensors used in the „selected Sensors list“ with the „Verify“ button

UMB-Config-Tool

Page 22: Umb E 2009 2010

Channel selection and measurement display

– Select the required channel by doubleclick

– Then change the status into active.

– To start the poll, please select in main menu „file“, „start measurement“.

UMB-Config-Tool

Page 23: Umb E 2009 2010

Configuration of UMB-module

– In “Edit”, “Sensors” click “Configure”

– Select the sensor for configuration– Click „Load profile from sensor“ to

read the configuration of the selected sensor

UMB-Config-Tool

Page 24: Umb E 2009 2010

Configuration example: WS600-UMB

• Select the fields according to connected sensors, then select „write configuration on sensor” and select „start“.

UMB-Config-Tool

Page 25: Umb E 2009 2010

Firmwareupdate• Example of firmwareupdates on WS600-UMB

Software: Hexload

Select firmware version via “File” button

Start Firmwareupdate with “F9” button on PC

UMB-Update

Page 26: Umb E 2009 2010

“Stand Alone”-solution SmartView3 as central software

Display data as tables and charts

Road conditions and camera archive

Page 27: Umb E 2009 2010

Questions

?UMB-Fragen

Page 28: Umb E 2009 2010

www.umb-technology.info

Page 29: Umb E 2009 2010

UMB-TechnologieUniversal-Measurement-Bus

www.lufft.com


Recommended