100
CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting Your Data Your Inspirations. Our Innovations.
Transcript
Page 1: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

CATALOGUE2015 Revision 1.0

UNINTERRUPTIBLEPOWER SUPPLY (UPS)

Protecting Your Data

Your Inspirations. Our Innovations.

Page 2: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting
Page 3: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

Table of Contents

Table ofContents

About Us - Company Profile

Online UPSProfessional Series (1P/1P) - TowerProfessional Series (1P/1P) - DualMaster Series (1P/1P) - TowerMaster E Series (1P/1P) - TowerMaster Series (1P/1P) - 2-in-1 Rack/ TowerMaster Series (3P/1P) - TowerMaster E Series (3P/1P) - TowerMaster Series (3P/1P) - Rack MountMaster Series (3P/3P) - TowerMaster E Series (3P/3P) - TowerPower SeriesPower E SeriesPPM SeriesPRO-R SeriesPRO-M SeriesPRO-EM SeriesGiant SeriesJupiter Series

Line Interactive UPSPRO SFC SeriesPRO SFT SeriesPRO SeriesPRO-L SeriesPRO Rack/ Tower SeriesOutdoor Line Interactive Series

Inverter UPSInverter Series

Auto Voltage RegulatorPVR Series

DC UPSPDC SeriesPBU Series

Solar UPSZonne SeriesPPS SeriesPCC SeriesPSI Hybrid SeriesPSI On-Grid Amnets SeriesPSI Off-Grid Haus SeriesPSI Off-Grid Haus MPPT Series

Software & Accessories

Appendix

02

04040608121419222527293136414446495254

58586062646668

7070

7474

757576

7777798183848586

89

94

01

Page 4: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

About Us - Company Profile

Our MissionAccentuate The Best For The E-generationPROLiNK® aspires to accentuate the best for the e-generation. With technology becoming an essential aspect of modern living, the e-generation concept has gradually become ingrained in our lives and digital literacy isbecoming more and more commonplace.

PROLiNK products are designed to make technology work for the e-generation. Created with the end-user in mind, our products are crafted to enhance performance whether you are at work or play – our products work harder, while you work smarter to achieve your desired results with less effort and better efficiency.

Providing value to our consumers – whether home or business users, remains a firm commitment of PROLiNK. With its wide range of quality products, PROLiNK makes it easy for home users to find user-friendly yet affordable solutions for their technological needs, while business users are assured of reliable and secure solutions for their network infrastructure.

Our VisionIdeas, Innovation and InformationPROLiNK® aims to be the key driving force behind technological changes and improvements in both developing and developed countries. With its strong focus on technology, our team sets high standards for itself in the areas of innovation, change and improvement so as to provide the next generation of users with products that are suita-ble for their technology advanced environments.

The small “i” in PROLiNK represents ideas, innovation and information – three key pillars of growth that drive us towards achieving excellence in our field of expertise and challenges us to think beyond our usual boundaries.

Fida International (S) Pte Ltd has been a provider of technologically innovative and user-friendly productsmanufactured under the brand name “PROLiNK®” since 1991. With more than two decades of professionalexperience in the information communications sector, PROLiNK is now renowned as a specialist in its field,especially in the area of Back-up UPS products.

Over the years, PROLiNK has built its presence through a strong foundation of technological leadership within the South Asian, South-east Asian and Middle Eastern regions and is continuing to build its presence worldwide. With its current network of sales offices in more than 20 countries, customers can be assured that PROLiNK is able to provide the right solutions to meet the needs of both home and business users within each geographical location both efficiently and effectively.

The company’s quest for continuous improvement and quality assurance to its customers has earned us the ISO9001 quality certification since 1999. With its consistently strong commitment to quality, customers can be assured of they are getting true value - superior quality products at affordable prices.

02

Page 5: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

Core ValuesSecured Information ManagementWith more than two decades of professional experience in providing backup power solutions to our customers, we are able to support our customers with superior technological know-how and expertise, as well as advice on market trends. At the same time, we are also fully committed to protecting the privacy of our customers and to manage confidential information discreetly.

Innovative DesignOur products are carefully thought out to ensure that each item is designed to meet the needs of our customers. With the team’s solid experience in the UPS market, customers can be certain that our designs are innovative yet functional, and suitable for each dynamic market that we have a presence in.

Superior Service StandardsStrict and rigorous testing makes up a huge part of our quality control procedures. We ensure that every item meets our strict standards – from the individual components to the actual finished product.

Total Quality Assurance SystemOur products go through careful planning and checks at every stage of the production cycle - from the beginning stages of product design to the manufacturing and finally the actual delivery of the goods. This guarantees that our customers receive only the best quality goods – of high reliability and durability. Our total quality system has been audited and approved by globally recognized bodies.

Range of UPSThe wide range of our products gives you an infinite range of solutions:1. Online UPS2. Line Interactive UPS3. Inverter UPS4. DC UPS4. Solar UPS

03

About Us - Company Profile

Page 6: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

04

Online UPS

Professional Series (1P/1P) - Tower

Online Professional Series 1kVA – 6kVA

Professional Series (1P/1P) is an advanced yet affordable single-phase UPS system that uses online double conversiontechnology. It is designed to protect against power outages,disturbances and spikes, making them most suitable for voltage fluctuating environments. This device is able to providehigh-efficiency charging with its high input power factor correction.

Professional Series is available in capacities ranging from 1000VA to 6000VA. High voltage battery chargers and battery extension assembly are made available for longer runtime applications. Users can also have the option to top-up an additional isolationtransformer to obtain pure and clean power for their sensitivedevices.

• True Double-Conversion Online UPS• Wide input voltage range (110~300VAC)• Input Power Factor correction of 0.98• Output Power Factor of 0.8• Generator compatible• LCD User Interface• Choice between RS-232 communication port or USB / RS-232 / AS400 / SNMP interface• Smart battery charger designed to optimize battery performance• Isolation transformer (optional)

Work-Stations ServersLocal AreaNetwork (LAN)

Small ComputerNetwork

Rear PanelFor 1kVA to 6kVA model1. Output receptacles2. AC input3. Input circuit breaker4. Network/Fax Modem Surge Protection5. Intelligent slot for communication port/ SNMP. (standard come with USB port)6. External battery connection (only available for L model)7. Output terminal8. Output circuit breaker9. Fan

5 6

9

432

1

5

9

3

27

1

8

46

PRO901S/LPRO902S/L

PRO903S/L

5

91

8

46

2 7

PRO906S/L

Page 7: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

05

Online UPS

Full Specifications

• RS-232 Port (communication interface)• AS-400 Card (External alarm indicator)• SNMP Card for data communication via network connection• Output Isolation Transformer• External PDU & Maintenance Bypass Switch (suitable for UPS up to 3kVA only)

Options

L stands for Long-run modelS stands for Standard modelI stands for Isolation Transformer (Optional)*All specifications, designs and contents are subject to change without prior notice.

≧ 0.98 @ Nominal Voltage (100% load) 40 ~ 70Hz (Auto sensing)

110-300 VAC ± 5 % Voltage RangeFrequency RangePower Factor

6000 VACapacity 1000 VA 2000 VA 3000 VA

Valve regulated Lead Acid battery (Maintenance free batteries)TypeCapacity

AC Mode to Batt. ModeInverter to Bypass

Recharge Time (Typical)Charging Current

Standard Model

Input / Output Voltage, Load Level, Batt Level, UPS Status, Fault Conditions

Safety: EN62040-1-1; EMI62040-2; EN62040-3Regulations

INPUT

MODELS PRO906S/ LPRO901S/ L PRO902S/ L PRO903S/ L

OUTPUT

BATTERY

MANAGEMENT

ENVIRONMENT

PHYSICAL

OVERLOAD

INDICATORS

EFFICIENCY

Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MACUSB

1.5 seconds>130%

100% < Load < 110%

LCD Display

AC Mode

±1%

3:1

Voltage Regulation (Batt. Mode)

Frequency Range (Batt. Mode)Frequency Range (Synchronized Range)

Current Crest RatioHarmonic Distortion

Transfer TimeZero

4 ms (Typical)Waveform (Batt. Mode)

1.0A (max)

50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz47 ~ 53 Hz or 57 ~ 63 Hz

Pure Sinewave

9AHBack to 90% capacity in 9 hours

Up to 88%

≦ 3 % THD (Linear Load), ≦ 7 % THD (Non-linear Load)

10AH

TypeLong-Run Model Capacity

Charging Current 1A / 2A / 4A / 8A (Default) 1A / 2A / 4A / 6A (Default)

Overload warning only (No shutdown)110% < Load <130% 30 seconds

Depending on the applicationDepending on the application

200/208/220/230/240 VAC or 100/110/115/120/127 VACOutput Voltage

397×145×22017.2

8.9

421 × 190 × 318

421×190×31828.7

13.1

426 × 190 × 318

426×190×31836.2

15.2

<90% (Non-condensing)0°C - +40°C

Operation HumidityAmbient Temperature

≤ 45dB @ 1 Meter < 55dB @ 1 MeterNoise Level

397 x 145 x 22010.8

5.7

Dimension (mm) D x W × HNet Weight (kgs)Dimension (mm) D × W × HNet Weight (kgs)

Standard Model

Long-Run Model

Page 8: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

06

Professional Series (1P/1P) - Dual

Online Professional Series1kVA – 3kVA

• True double-conversion• Accepts dual input voltage for special power environment with High Voltage and Low Voltage• Complete galvanic isolation design offers full isolation andcomplete common mode noise rejection• Wide input voltage range (88-144VAC and 176-288VAC) at full load• Selectable output voltage at 110VAC or 220VAC• ECO mode for energy saving• Input power factor correction 0.99• Output voltage regulation < ± 1%• Mini slot for USB / RS-232 / AS400 / SNMP communication• Smart battery charger design for optimized battery performance

Professional Series (1P/1P) - Dual is an advanced yet affordable single-phase UPS system that uses on-line double conversiontechnology with 2 different input voltage ranges. It is designed to protect against power outages, disturbances and spikes, making them most suitable for voltage fluctuating environments.

Professional Series (1P/1P) – Dual is most suitable to be used in areas that are plagued by voltages that are as low as 100V. With the advanced double-conversion technology, the dual series is able to regulate and maintain consistent output even when it is fully loaded. Also, this device is able to provide full isolation and complete common mode noise rejection from complementary equipment. The Dual Series is available in various capacities, ranging from 1000VA to 3000VA.

Online UPS

Rear Panel

PRO902DS/DL PRO903DS/DL

Work-Stations ServersLocal AreaNetwork (LAN)

Small ComputerNetwork

For 1kVA to 3kVA model1. Output receptacles2. AC input3. Input circuit breaker4. Network/Fax/Modem surge protection5. Intelligent slot for communication port/SNMP (standard come with USB port)6. External battery terminal (only available for Long-run model)7. Output terminal8. Output circuit breaker9. Fan PRO901DS/DL

5

9

9

6

1

2

34

5

9

9 6

1

2

9

4

5

9

9

9

86

1

2 7

4

Page 9: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

07

Online UPS

• RS-232 Port (communication interface)• AS-400 Card (External alarm indicator)• SNMP Card for data communication via network connection• External PDU & Maintenance Bypass Switch (suitable for UPS up to 3kVA only)

Options

L stands for Long-run modelS stands for Standard modelI stands for Isolation Transformer (Optional)*All specifications, designs and contents are subject to change without prior notice.

Full Specifications

45Hz ~ 55 Hz or 56Hz ~ 65 Hz 88-144 VAC and 176 - 288 VAC (Auto sensing)

110/115/120/127 VAC or 208/220/230/240 VAC (Auto sensing)Nominal VoltageVoltage RangeFrequency RangePower Factor ≧ 0.99 @ Nominal Voltage (100% Load)

110/115/120/127 VAC or 208/220/230/240 VAC

Capacity 1000 VA 3000 VA

12V / 9AhBattery TypeBattery NumbersRecharge Time (Typical)Charging Current

Standard Model

Sounding twice every secondSounding every second

Continously sounding

RS232 Card / Optional USB Card, SNMP Card, or AS400 CardSupports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MAC

Communication

INPUT

MODELS PRO901DS/DL2000 VA

PRO902DS/DL PRO903DS/DL

OUTPUT

BATTERY

MANAGEMENT

ENVIRONMENT

PHYSICAL

INDICATORS

Low Battery

ALARM

EFFICIENCY (Peak)

Power management from SNMP manager and web browserOptional SNMP

Sounding every 4 secondsBattery Mode

LCD Panel

OverloadFault

AC Mode (@100% RCD load)Battery Mode(@100% RCD load)ECO Mode

47 Hz ~ 53 Hz or 57 Hz ~ 63 Hz

≦ 2 % THD (Linear Load) ; ≦ 6 % THD (Non-linear Load)

AC Voltage Regulation (Static)

Frequency Range (Batt. Mode)Frequency Range (Synchronized Range)

Current Crest RatioHarmonic Distortion

Transfer TimeAC Mode to Battery ModeAC Mode to BypassBypass to AC Mode 4 ms (Typical)

4 ms (Typical)

Waveform (Batt. Mode)

1.0A (max)Charging Voltage 54.8 VDC ±1% 82.2 VDC ±1%27.4 VDC ± 1%

3:150 Hz ± 0.2 Hz or 60Hz ± 0.2 Hz

Pure Sinewave

4 62

85%84% (Typical); 86% (Peak) 86% (Typical); 88% (Peak) 87% (Typical); 89% (Peak)

88% 90%

Back to 90% capacity in 5 hours

77% (Typical); 79% (Peak)76% (Typical); 78% (Peak) 78% (Typical); 80% (Peak)

Zero

Battery Type and NumbersLong-Run Model Charging Current

Charging Voltage

UPS status, Load level, Battery level, Input / Output / battery info, Discharge timer, and Fault conditions

4A or 8A54.8 VDC ±1% 82.2 VDC ±1%27.4 VDC ± 1%

Depending on application

± 1%Output Voltage

423 x 145 x 332

426 x 190 x 448

426 x 190 x 448

426 x 190 x 448

426 x 190 x 448

20-95 % RH @ 0- 40°C (Non-condensing)Less than 50dBA @ 1 Meter

Operation HumidityNoise Level

423 x 145 x 33226.5 34 56

21.5 23 41

Dimension (mm) D x W × HNet Weight (kgs)Dimension (mm) D × W × HNet Weight (kgs)

Standard Model

Long-Run Model

Page 10: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

08

Online UPS

Master Series (1P/1P) - Tower

Online Master Series1kVA – 10kVA

Master Series (1P/1P) is a single-phase UPS system that employs a true online double-conversion technology. It is designed to deliver clean and high quality electrical power for devices such as small computer centres, servers, telecom applications, lab testing equipments and industrialapplications. The Master series (1P/1P) comes with a wide input voltage range that protects devices against outages, disturbances and spikes. In addition, this device comes with a smart battery charger that optimizes the battery performance, ensuring longer lasting battery life. High voltage battery chargers and battery extension assembly are made available for longer runtime applications. The Master series (1P/1P) also comes in various capacities ranging from 1kVA to 10kVA to suit your needs. The 6kVA and 10kVA UPS system comes with 2 additional features; an internal bypass system and a parallel redundant system. An internal bypass system allowing continuous power is integrated for convenience when maintenance is necessary and a parallel redundant system that allows two UPS models to operate in parallel as backup for each other.

• True Double-Conversion Online UPS• Output Power Factor 0.8• Wide input voltage range (110~300V)• Programmable power management outlets• 50/60 Hz Frequency Converter Mode• ECO mode operation for energy saving• Emergency Power Off (EPO) Function• SNMP/USB+RS-232 multiple communications (SNMP is optional)

• DSP technology applied for 6K and up models• Smart battery charger design to optimize battery performance• Maintenance bypass available for 6K and up models• Optional hot standby mode and N+X parallel redundancy available for 6K and up models• Adjustable battery numbers for 6K and up models• Built-in isolation transformer (Option)

Work-Stations ServersLocal AreaNetwork (LAN)

Small ComputerNetwork

Rear PanelFor 1kVA to 3kVA model1. Programmable outlets: connect to non-critical loads2. Output receptacles: connect to mission critical loads3. AC input4. Input circuit breaker5. Network/ Fax/ Modem surge protection6. Emergency power off function connector (EPO)7. USB communication port8. RS-232 communication port9. SNMP intelligent slot10. External battery connection (only available for L model)11. Output terminal12. Output circuit breaker13. Fan

PRO802S/L PRO803S/LPRO801S/LPRO8015S/L

9

56

87

13

10

4

32

1

9

5

2 1

7 8

6

43

1013

13

9

5

2 1

7 8

6

3

4

1012

11

13

13

Page 11: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

09

Online UPS

For 6kVA to 10kVA model1. RS-232 communication port2. USB communication port3. Emergency power off function connector (EPO connector)4. Share current port (only available for parallel model)5. Parallel port (only available for parallel model)6. Intelligent slot7. Charger fan8. Power stage fan9. Maintenance bypass switch10. Input circuit breaker11. Input/Output terminal12. Output terminal 113. Output terminal 214. External battery terminal (only available for Long-run model)15. Utility input terminal16. Output IEC Socket

9

5 521

78

8

643

1512 13

14

16 11

10

PRO806S/LPRO810S/L

Battery PackFor 1kVA to 3kVA model

For 6kVA to 10kVA model

Model

Battery Type

Battery Number (max)

Dimension (DxWxH) mm

Weight (kg)

G6

6 pcs

18

6 pcs

397 × 145 × 220

20

12 pcs

36

G18G12

12 pcs 18 pcs 18 pcs

421 × 190 × 318

40 55

12V9AH12V7AH 12V7AH 12V9AH 12V7AH 12V9AH

535 × 190 × 318

61

Model

Battery Type

Battery Number (max)

Dimension (DxWxH) mm

Weight (kg)

40 pcs

109

G40 G60

40 pcs 60 pcs 60 pcs

592 × 250 × 576

125 166

12V7AH 12V9AH 12V7AH / 12V9AH

830 × 250 × 576

190

Page 12: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

10

Online UPS

Options• AS-400 Card (External alarm indicator)• SNMP Card for data communication via network connection• Output Isolation Transformer• External PDU & Maintenance Bypass Switch (Only suitable for UPS that are up to 3kVA)

A derate will occur during the Frequency converter mode (Capacity is reduced to 60%) and when the output voltage is adjusted to 208VAC (Capacity is reduced to 80%). If the UPS is installed in a location where the altitude is above 1000m, the output power must be lowered by one percent for every 100m covered. L stands for Long-run modelS stands for Standard modelI stands for Isolation Transformer (Optional)*All specifications, designs and contents are subject to change without prior notice.

Full Specifications

55-150 VAC ± 5 % or 110-300 VAC ± 5 % at 50% load80-150 VAC ± 5 % or 160-300 VAC ± 5 % at 100% load

110-300 VAC at 50% load176-300 VAC at 100% load

200/208/220/230/240 VAC or 100/110/115/120/127 VAC 208/220/230/240 VACNominal Voltage

Voltage Range

Frequency RangePower Factor

40 ~ 70Hz 46 ~ 54 Hz or 56 ~ 64 Hz≧ 0.99 @ Nominal Voltage (100% Load) ≧0.99 @ 100% Load

Phase Single phase with ground

12 V / 7 Ah 12 V / 9 Ah 12 V / 7 Ah 12 V / 9 Ah 12 V / 7 Ah 12 V / 9 AhTypeNumber

Recharge Time (Typical)

Charging CurrentCharging Voltage

Numbers

Standard Model

Sounding twice every secondSounding every second

Continuously sounding

Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MAC

INPUT

MODELS PRO803S/ L PRO806S/ L

3000 VACapacity 1000 VA 1500 VA 2000 VA 6000 VA 10000 VA

PRO810S/ LPRO801S/ L PRO8015S/ L PRO802S/ L

OUTPUT

BATTERY

MANAGEMENT

ENVIRONMENT

PHYSICAL

INDICATORS

ALARM

EFFICIENCY

Power management from SNMP manager and web browserOptional SNMP

Smart RS-232USB

Sounding every 4 secondsBattery ModeLow Battery

LCD Display

OverloadFault

AC ModeBattery Mode

±1%

3:1

Voltage Regulation (Batt. Mode)

Frequency Range (Batt. Mode)Frequency Range (Synchronized Range)

Current Crest Ratio

Harmonic Distortion

Transfer Time AC Mode to Batt. ModeInverter to Bypass

Zero4 ms (Typical) Zero

Waveform (Batt. Mode)

1.0A (max)

50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz47~53 Hz or 57~63 Hz 46 ~ 54 Hz or 56 ~ 64 Hz

Pure Sinewave

63

3 6

Back to 90% capacity in 4 hours Back to 90%capacity in 7 hours

Back to 90%capacity in 9 hours

87%90%

83%87%

88%89%

≦ 3 % THD (Linear Load)≦ 6 % THD (Non-linear Load)

≦ 2 % THD (Linear Load)≦ 4 % THD (Non-linear Load)

20

Battery Type

Long-Run ModelCharging CurrentCharging Voltage 82.1 VDC ±1%41.0 VDC ± 1% 273.0 VDC ±1%

82.1 VDC ±1%41.0 VDC ± 1% 273.0 VDC ±1%

UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions

8.0A 4.0A18-20

Depending on the application

200/208/220/230/240 VAC or 100/110/115/120/127 VAC 208/220/230/240 VACOutput Voltage

397×145×22026 28

13

421 × 190 × 318

421×190×31881

13

592 x 250 x 576

592 x 250 x 57683

25 27

20-90 % RH @ 0- 40°C (Non-condensing)

Less than 50dB@1Meter Less than55dB@1Meter

Less than58dB@1Meter

Operation Humidity

Noise Level

397 x 145 x 22013 14

7 7

Dimension (mm) D x W × HNet Weight (kgs)Dimension (mm) D × W × HNet Weight (kgs)

Standard Model

Long-Run Model

Page 13: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

11

Online UPS

Programmable Outlets (P1)- connect to non-critical devices

True double-conversion Online UPSA true double conversion UPS will provide clean, high level quality power to fully protect mission-criticaldevices such as sensitive networks, small computer centers, servers, telecom applications, as well as for industrial applications.

Higher Accuracy for Output VoltageThe advanced control firmware allows the Master Series (1P/1P) to achieve higher accuracy with the output voltage tolerance of +/- 1%. The device is applicable for the use with critical test and IT equipments.

Smart Battery Charger Design to OptimiseBattery PerformanceMaster Series (1P/1P) 1-3kVA models are equipped with a 2-stage charger design to guarantee precise battery discharge time. The charging voltage is alsoautomatically adjusted according to the ambient temperature, to lengthen the service life of the battery.

The 6kVA and 10kVA models come with an additional extendable charger that allows for large-capacity battery charging.

DSP Technology (Applies for the above models)A DSP controller improves the performance andefficiency of the UPS.

Maintenance Bypass Available For 6kVA And Above ModelsInternal bypass assures continuous power to critical devices during UPS maintenance.

Optional Hot Standby and N+X ParallelRedundant System (Available for Models ranging from 6kVA and above)An internal bypass system allowing continuous power is integrated for convenience when maintenance isnecessary and a parallel redundant system that allows two UPS models to operate in parallel as backup for each other.

Output Power factor of 0.8As compared to the online UPS models in the current market, the Master Series (1P/1P) provides better output power factor of up to 0.8. This unit is able to offer higher performance and efficiency for your critical applications.

Wide Input Voltage Range (110 V -300 V)Master Series (1P/1P) can still provide stable power to connected devices under unstable power environments.

50/60 Hz Frequency Converter ModeLock output frequency at 50Hz or 60Hz to suit power sensitive equipments.

ECO Mode Operation For Energy SavingOffers efficiency as high as 97% to cut energy usage & cost. UPS power application via static bypass, timely returning to online double conversion when the need arises.

Emergency Power Off (EPO) FunctionThis feature can protect the personnel and theequipment in the case of fire outbreak or other types of emergency.

SNMP + USB + RS-232 MultipleCommunication port for Models ranging from 1 to 3kVA.This feature allows either the USB or RS-232communication port to simultaneously operate with the SNMP interface.

Programmable Power Management Outlets The programmable power management outlets allow users to easily and independently control the load segment. In the event of a power failure, this feature enables users to manage and extend the battery time for mission critical devices by shutting down the non-critical devices.

Page 14: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

12

Online UPS

Master Series (1P/1P) - Tower

Online Master E Series6kVA – 10kVA

Work-Stations ServersLocal AreaNetwork (LAN)

Small ComputerNetwork

Rear PanelFor 6kVA to 10kVA model1. RS-232 communication port2. USB communication port3. Emergency power off function connector (EPO connector)4. Share current port (only available for parallel model)5. Parallel port (only available for parallel model)6. Intelligent slot7. Charger fan8. Power stage fan9. Maintenance bypass switch10. Input circuit breaker11. Input/Output terminal12. Output terminal 113. Output terminal 214. External battery terminal (only available for Long-run model)15. Utility input terminal16. Output IEC Socket

9

5 521

78

8

643

1512 13

14

16 11

10

PRO806ES/ELPRO810ES/EL

Master E Series (1P/1P) is a single-phase UPS system that employs a true online double-conversion technology. It is designed to deliver clean and high quality electrical power for devices such as small computer centres, servers, telecom applications, lab testing equipments and industrial applications. The Master E Series (1P/1P) comes with a wide input voltage range that protects devices against outages, disturbances and spikes. In addition, this device comes with a smart battery charger that optimizes the battery performance, ensuring longer lasting battery life. High voltage battery chargers and battery extension assembly are made available for longer runtime applications. The E-Series provides better output power factor of up to 0.9, offering high performance and efficiency for your critical applications. The Master E Series (1P/1P) comes with 2 additional features; an internal bypass system and a parallel redundant system. An internal bypass system that allows continuous power is integrated for convenience when maintenance is necessary and a parallel redundant system that allows two UPS models to operate inparallel as backup for each other.

• True double-conversion• DSP technology guarantees high performance• Output power factor 0.9• Wide input voltage range (110-300 VAC)• Active input power factor correction 0.99• 50Hz/60Hz frequency converter mode• Eco mode operation for energy saving (ECO)• Programmable power management outlets

• Emergency power off function (EPO)• Generator compatible• Charger capacity expansion to 8A for long-run models• SNMP/USB/RS-232 communications• 3-stage extendable charging design for optimized battery performance• Adjustable battery numbers• Maintenance bypass available

0.9Output Power

Factor

Page 15: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

13

Online UPS

Full Specifications

Options• AS-400 Card (External alarm indicator)• SNMP Card for data communication via network connection• Output Isolation Transformer

A derate will occur during the Frequency converter mode (Capacity is reduced to 60%) and when the output voltage is adjusted to 208VAC (Capacity is reduced to 80%). If the UPS is installed in a location where the altitude is above 1000m, the output power must be lowered by one percent for every 100m covered. L stands for Long-run modelS stands for Standard modelI stands for Isolation Transformer (Optional)*All specifications, designs and contents are subject to change without prior notice.

110-300 VAC at 50% load176-300 VAC at 100% load

208/220/230/240 VACNominal Voltage

Voltage Range

Frequency RangePower Factor

46~54 Hz or 56~64 Hz≧ 0.99 @ full load

CapacityPhase

12 V / 7 Ah 12 V / 9 AhTypeNumbersRecharge Time (Typical)Charging CurrentCharging Voltage

Standard Model

Sounding twice every secondSounding every second

Continously sounding

Supports Windows2 2000/2003/XP/Vista/2008, Windows2 7/8, Linux, Unix, and MACSmart RS-232 / USB

INPUT

MODELS

6000 VASingle phase with ground

PRO806ES/EL

10000 VA

PRO810ES/EL

OUTPUT

BATTERY

MANAGEMENT

ENVIRONMENT

PHYSICAL

INDICATORS

INDICATORS

EFFICIENCY

Power management from SNMP manager and web browserOptional SNMP

Sounding every 4 secondsBattery ModeLow Battery

LCD Display

OverloadFault

AC ModeBattery Mode

±1%

3:1 (max)

AC Voltage Regulation (Batt. Mode)

Frequency Range (Batt. Mode)Frequency Range (Synchronized Range)

Current Crest RatioHarmonic Distortion

Transfer Time AC Mode to Batt. ModeInverter to Bypass

ZeroZero

Waveform (Batt. Mode)

Depending on the application

50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz46~54 Hz or 56~64 Hz

Pure Sinewave

207 hours recover to 90% capacity 9 hours recover to 90% capacity

89%88%

≦ 3 % THD (Linear Load), ≦ 6 % THD (Non-linear Load)

Type

Long-Run Model Charging CurrentNumbers

Charging Voltage 273 VDC ± 1%

UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions

4.0 A (max)18-20

273 VDC ± 1%1.0 A (max)

200/ 208/ 220/ 230/ 240VACOutput Voltage

81592 x 250 x 576

592 x 250 x 57683

25 27

20-90 % RH @ 0- 40°C (Non-condensing)Less than 55dBA @ 1 Meter Less than 58dB @ 1 Meter

Operation HumidityNoise Level

Dimension (mm) D x W × HNet Weight (kgs)Dimension (mm) D × W × HNet Weight (kgs)

Standard Model

Long-Run Model

Page 16: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

14

0.9Output Power

Factor

Online UPS

Master Series (1P/1P) - 2-in-1 Rack/ Tower

Online Master Series 1kVA – 10kVA

Master Series (1P/1P) – 2-in-1 Rack/Tower is a single-phase UPS system that employs a true onlinedouble-conversion technology. This device comes with a practical 2U universal-mount case that provides an option for the user to either install it as a floor-standing tower or in a mounted position using a 19-inch rack mount bracket. With its high density output power factor of 0.9, this device is able to provide outstanding performance and efficiency to meet the requirements of a mission critical environment.

This 2-in-1 Rank/Tower UPS is brilliantly designed with a hot-swapping battery feature to facilitate thereplacement of the existing batteries without the hassle of having to shut the devices down. On top of that, models with a 6kVA and 10kVA capacity comes with a parallel redundant system that allows two UPS models to operate in parallel and as backup for each other. High voltage battery chargers and battery extension assembly are made available for longer runtime applications. The PROLiNK 2-in-1 Rank/Tower UPS comes with a wide range of capacities from as low as 1kVA to as high as 10kVA to accommodate to your every need.

• True Double-Conversion Online UPS• Output Power factor of 0.9• User-friendly and easy-shift LCD display• Rack/ Tower design• Programmable power management outlets for 1-3K• 50/60 Hz frequency converter mode• ECO and advanced ECO mode for energy saving• Emergency Power Off Function (EPO)• Hot-swappable battery design for all model• DSP technology applied for 6K and up models• Active input power factor correction 0.99 for 6K and up models• N+X parallel redundancy available for 6K and up models

Work-Stations Servers 19” RackMount

Local AreaNetwork (LAN)

Small ComputerNetwork

Page 17: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

15

Online UPS

Rear PanelFor 1kVA to 3kVA model1. Programmable outlets: Connect to non-critical loads2. Output receptacles: Connect to mission-critical loads3. AC input4. Input circuit breaker5. Network/Fax/Modem surge protection6. Emergency power off function connector (EPO)7. USB communication port8. RS-232 communication port9. SNMP intelligent slot10. External battery terminal (only available for Long-run model)11. Output IEC320-C20 connector12. Fan

For 6kVA to 10kVA model1. Programmable outlets: Connect to non-critical loads2. Output receptacles: Connect to mission-critical loads3. AC input4. Input circuit breaker5. Network/Fax/Modem surge protection6. Emergency power off function connector (EPO)7. USB communication port8. RS-232 communication port9. SNMP intelligent slot10. Battery connection11. Input terminal12. Fan13. Parallel port (only available for parallel model)14. External maintenance by-pass switch connection15. Output Terminal16. Ground

PRO806RS/RLPRO810RS/RL

69 47

7

121014

13

11 16 15

Battery PackFor 1kVA to 3kVA model

Capacity

Battery Type

Battery Number (max)

Dimension (DxWxH) mm

Net Weight (kg)

1K

4 pcs

380 x 438 x 88

17.3

1.5K 2K 3K

6 pcs 8 pcs 12 pcs

24.8 29.8

12 V / 9 Ah 12 V / 9 Ah 12 V / 9 Ah 12 V / 9 Ah

600 x 438 x 88480 x 438 x 88

42.5

For 6kVA to 10kVA modelCapacity

Battery Type

Battery Number (max)

Dimension (DxWxH) mm

Net Weight (kg)

6K

20 pcs

580 x 438 x 133

57

10K

20 pcs

63

12 V / 7 Ah 12 V / 9 Ah

PRO803RS/RL

5 12 12 10 6

7

89

1

2

311

4

PRO801RS/RL PRO8015RS/RL PRO802RS/RL

5 12 106

7

89

1

2

3

4

Page 18: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

16

Online UPS

• AS-400 Card (External alarm indicator)• SNMP Card for data communication via network connection• MODBUS Card (communication interface)• Universal Rackmount Slider for installation in rack cabinets• External PDU & Maintenance Bypass Switch (Only suitable for UPS that are up to 3kVA)• Maintenance Bypass Switch [MBS] (Only available in UPS ranging from 6 to 10kVA)• External Automatic Transfer Switch (ATS)

Options

Full Specifications

L stands for Long-run modelS stands for Standard model*All specifications, designs and contents are subject to change without prior notice.

40Hz ~ 70Hz55-150 VAC ± 5% or 110-300 VAC ± 5%

100*/110*/115*/120 /127 VAC or 200/208/220/230/240 VACNominal Voltage

Phase

Voltage RangeFrequency RangePower Factor ≧ 0.99 @ Nominal Voltage (100% Load)

3000 VACapacity 1000 VA 1500 VA 2000 VASingle phase with ground

12 V / 9 AhBattery TypeNumberRecharge Time (Typical)Charging Current (Max.)Charging Voltage

Standard Model

Sounding twice every secondSounding every second

Continously sounding

Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MACSmart RS-232 / USB

INPUT

MODELS PRO803RS/ RLPRO801RS/ RL PRO8015RS/ RL PRO802RS/ RL

OUTPUT

BATTERY

MANAGEMENT

ENVIRONMENT

PHYSICAL

INDICATORS

ALARM

EFFICIENCY

Power management from SNMP manager and web browserOptional SNMP

Sounding every 4 secondsBattery ModeLow Battery

LCD Display

OverloadFault

AC Mode

±1%

5:1 (max.)

Voltage Regulation (Batt. Mode)

Frequency Range (Batt. Mode)Frequency Range (Synchronized Range)

Current Crest RatioHarmonic Distortion (Line Mode)

Transfer Time Line Mode to Battery ModeInverter to Bypass 4 ms

Zero

Waveform (Batt. Mode)

Battery ModeECO Mode

85%94%

50 Hz ± 0.5% or 60Hz ± 0.5%47 ~ 53 Hz or 57 ~ 63 Hz

Pure Sinewave

2Back to 90% capacity in 4 hours

87%86%95%

88%87%97%

89%

≦ 2 % THD (Linear Load) ; ≦ 4 % THD (Non-linear load)

Battery TypeLong-Run Model Number

Recharge Time (Typical)Charging Current (Max.)Charging Voltage

Depending on the capacityof external batteries

27.4 VDC ± 1%

27.4 VDC ± 1%

1A / 2A / 4A / 8A

1.0A

3 4

41.1 VDC ± 1% 54.7 VDC ±1%

41.1 VDC ± 1% 54.7 VDC ±1%

6

82.1 VDC ±1%

82.1 VDC ±1%

Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicator

100*/110*/115*/120/127 VAC or 200/208/220/230/240 VACOutput Voltage

380x438x88 (2U) 480x438x88 (2U)20.6 28

11.3

480x438x88 (2U)

600x43x88(2U)13.8

600x438x88 (2U)

20-90 % RH @ 0- 40°C (Non-condensing)Less than 50dBA @ 1 Meter

Operation HumidityNoise Level

380x438x88 (2U)12.9 17.6

8.6 10.7

Dimension (mm) D x W × HNet Weight (kgs)Dimension (mm) D × W × HNet Weight (kgs)

Standard Model

Long-Run Model

Page 19: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

17

Online UPS

Full Specifications

L stands for Long-run modelS stands for Standard model*All specifications, designs and contents are subject to change without prior notice.

46~54 Hz or 56~64 Hz110-300 VAC ± 3% at 50% load; 176-300 VAC ± 3% at 100% load

200/208/220/230/240 VACNominal Voltage

Phase

Voltage RangeFrequency RangePower Factor ≧ 0.99 @ 100% load

Capacity 6000 VA 10000 VASingle phase with ground

240 VDCNominal VoltageBattery TypeNumbersRecharge Time (Typical)Charging Current (max.)Float Charging Voltage

Standard Model

Sounding twice every secondSounding every second

Continously sounding

Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MACSmart RS-232 / USB

INPUT

MODELS PRO806RS/ RL PRO810RS/ RL

OUTPUT

BATTERY

MANAGEMENT

ENVIRONMENT

PHYSICAL

INDICATORS

ALARM

EFFICIENCY

Power management from SNMP manager and web browserOptional SNMP

Sounding every 4 secondsBattery ModeLow Battery

LCD Display

OverloadFault

Line Mode

±1% ±1%

3:1 (Max.)

AC Voltage Regulation

Frequency Range (Batt. Mode)Frequency Range (Synchronized Range)

Current Crest Ratio

Harmonic Distortion

Transfer Time

Line Mode to Battery ModeBattery Mode to Line modeInverter to BypassBypass to Inverter

4 ms

0 ms

Waveform (Batt. Mode)

Battery ModeECO Mode

88%96%

50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz46~54 Hz or 56~64 Hz

Pure Sinewave

12 V / 7 Ah20 (18-20 pcs adjustable)*20 (18-20 pcs adjustable)*

90%88%96%

90%

≦ 2 % THD (Linear Load),≦ 4 % THD (Non-linear Load)

≦ 2 % THD (Linear Load),≦ 4 % THD (Non-linear Load)

Battery Type and NumbersLong-Run Model Charging Current (max.)

Float Charging Voltage

Depending on the application4.0 A

273 VDC (based on battery numbers at 20 pcs)

273 VDC (based on battery numbers at 20 pcs)

Back to 90% capacity in 7 hours Back to 90% capacity in 9 hours

12 V / 9 Ah

1.0 A

Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicator

200/208/220/230/240 VAC 200/208/220/230/240 VACNominal Voltage

UPS Unit: 23.5Battery Pack: 63

0-95 % RH @ 0- 40°C (Non-condensing)Less than 58dBA @ 1 Meter Less than 60dBA @ 1 Meter

Operation HumidityNoise Level

UPS Unit: 580 x 438 x 133 (3U)Battery Pack: 580 x 438 x133 (3U)

UPS Unit: 20Battery Pack: 57

Dimension (mm) D x W × H

Net Weight (kgs)Standard Model

Long-Run Model

UPS Unit: 668 x 438 x 133 (3U)Battery Pack: 580 x 438 x133 (3U)

23.5580 x 438 x 133

20Dimension (mm) D x W × HNet Weight (kgs)

668 x 438 x 133

Page 20: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

18

Online UPS

Programmable Outlets (P1)- connect to non-critical devices

True Double-conversion Online UPSA true double conversion UPS system will provide clean and high quality electrical power to fully protect mission critical systems such as sensitive networks, small computer centers, servers, telecom applications and industrial applications.

Programmable Power Management OutletsThe programmable power management outlets allow users to easily and independently control the load segment. In the event of a power failure, this feature enables users to manage and extend the battery time for mission critical devices by shutting down the non-critical devices.

ECO and Advanced ECO Mode for Energy SavingIt allows the UPS to operate in high efficiency of up to 97% during energy saving ECO mode and 98% inoperation mode. In the event of an electrical AC failure, the inverter will automatically step-in and provideelectrical supply to the connected systems.

Emergency Power Off Function (EPO)This feature provides adequate protection for the user and the equipment against hazards such as fire break-out or other emergencies.

Hot-swapping Battery DesignThe hot-swapping battery feature helps to facilitate the replacement of the existing batteries without the hassle of having to shut the devices down.

Long Battery Runtime Models AvailableOur Long Battery Runtime Models offers the flexibility to add-on additional external batteries to provide a longer back-up time.

User-friendly LCD DisplayThe front panel digital display comes with anauto-rotation feature that caters to your installationpreference; either vertically or wall mounted.

Rack / Tower DesignThis device comes with a practical 2U universal-mount case that provides an option for the user to either install it as a floor-standing tower or in a mounting position using a 19-inch rack mount bracket.

High Output Crest RatioThe Master (1P/1P) 2-in-1 Rack/Tower Series is designed with a high output crest ratio of 5:1 that allows the device to be extremely compatible with equipment such as compressors, generators and motors.

Output Voltage Regulation (tolerance +/- 1%)The Master (1P/1P) 2-in-1 rack / Tower Series is able to produce extremely stable and clean electrical power with its high efficiency output voltage regulator. This regulator is able to achieve a tolerance of +/- 1%, making it extremely compatible even with sensitive power supplies.

Output Power Factor 0.9Master (1P/1P) 2-in-1 rack/Tower Series is ahigh-density UPS system with an output power factor of 0.9. With this high power factor, the Master series is able to provide higher performance to critical applications.

Rack Display Tower Display

19” Rack-mounting Floor-standing Tower

Page 21: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

19

Online UPS

Master Series (3P/1P) - Tower

Online Master Series 10kVA – 30kVA

• True double-conversion• DSP technology guarantees high performance• Output power factor 0.8• Wide Input Voltage Range (305-478VAC for 3-Phase/ 100-300VAC for 1-Phase)• Supports Auto Phase Adaptation• Active power factor correction in all phases• Built-in phase auto adapt function simplifies wire installation• 50Hz/60Hz frequency converter mode• ECO mode operation for energy saving

• Programmable power management outlets• Emergency power off function (EPO)• Generator compatible• SNMP/USB+RS-232 multiple communications (SNMP is optional)• 3-stage extendable charging design for optimized battery performance• Adjustable battery numbers• Maintenance bypass available• Optional N+X parallel redundancy• Optional isolation transformer available

DataCentre

Electro-MedicalDevice

StoragePLCS

EmergencyAlarm

Devices

E-Business(Server Farms,ISP/ASP/POP)

Local AreaNetwork

(LAN)

TelecommunicationDevices

PRO83110S/L

Rear PanelFor 10kVA model1. RS-232 communication port2. USB communication port3. Emergency power off function connector (EPO connector)4. Share current port (only available for parallel model)5. Parallel port (only available for parallel model)6. Intelligent slot7. Charger fan8. Power stage fan9. Maintenance by-pass switch10. Input circuit breaker11. Output circuit breaker for receptacles12. Output receptacles: connect to mission-critical loads13. Input/Output terminal14. External battery connector (Only available for Long-run Model)

5 5

13

14

12

10

7

8

8

9

61 2 3 4

11

Master Series (3P/1P) three-phase input / single-phase output, true online double conversion UPS system guarantees consistent and quality electrical power to protect your mission critical applications such as mid-sized business servers, telecommunication systems and industrial equipment. The (3P/1P) UPS is designed with a wide input voltage range to handle voltage fluctuating situations and a high accuracy output voltage to fail-safe your equipment.

This Voltage Frequency Independent (VFI) system is available in capacities from 10kVA to 30kVA. By adopting the latest IGBT technology, this device is able offer excellent voltage switching characteristics during generator operation. An internal bypass system allowing continuous power is also integrated for convenience when maintenance is necessary. In addition, this device comes with a parallel redundant system that allows two UPS models to operate in parallel and as backup for each other. The Master series (3P/1P) UPS also offers the option of adding on an isolation transformer to suit your requirements.

Page 22: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

20

Online UPS

PRO83115LPRO83120L

PRO83115SPRO83120S

PRO83130S/LPRO83130L

For 15kVA to 30kVA model1. RS-232 communication port2. USB communication port3. Emergency power off function connector (EPO connector)4. Share current port (only available for parallel model)5. Parallel port (only available for parallel model)6. Intelligent slot7. Charger fan8. Power stage fan9. Maintenance by-pass switch10. Input circuit breaker11. Output circuit breaker for receptacles12. Output receptacles: connect to mission-critical loads13. Input/Output terminal14. Output Terminal: Connect to mission-critical loads15. Programmable Output terminal: Connect to non-critical loads16. External battery terminal (only available for Long-run model)17. Utility input terminal18. Grounding terminal (only available for parallel system)

5 5

11

18

10

7

78

8

9

61 2 3 4

5 5

11

10

7

78

8

9

61 2 3 4

For 15K & 30K modelFor 10K model

14 15 1715 16 1714

18

• AS-400 Card (External alarm indicator)• SNMP Card for data communication via network connection• MODBUS Card (Communication interface)• Output Isolation Transformer (Available only for Long-run Model)

Options

Page 23: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

21

Online UPS

L stands for Long-run modelS stands for Standard modelI stands for Isolation Transformer (Optional)*All specifications, designs and contents are subject to change without prior notice.

46~54Hz or 56~64Hz305-478 VAC (3-phase) at 100% load ; 190-520 VAC (3-phase) at 50% load

3 x 400VAC (3Ph+N)Nominal VoltageVoltage RangeFrequency RangePower FactorTHDi

≧ 0.99 @ 100% Load< 6% @ 100% load

Phase 3-phase in / 1-phase out

12 V / 9 AhBattery Type

Numbers

AC Mode to Batt. ModeInverter to Bypass

Recharge Time (Typical)Charging Current (Max.)Charging Voltage

Standard Model

Sounding twice every secondSounding every second

Power management from SNMP manager and web browserOptional SNMP

INPUT

MODELS PRO83110S/ L PRO83115S/ L PRO83120S/ L

Capacity 10 kVA 15 kVA 20 kVA 30kVA

PRO83130S/ L

OUTPUT

BATTERY

MANAGEMENT

ENVIRONMENT

PHYSICAL

INDICATORS

ALARM

EFFICIENCY

Sounding every 4 secondsBattery ModeLow Battery

LCD Display

OverloadFault Continously sounding

AC Mode

±1%

3:1

Voltage Regulation (Batt. Mode)

Frequency Range (Batt. Mode)Frequency Range (Synchronized Range)

Current Crest Ratio

Harmonic Distortion

Transfer Time

≦ 2 % THD (Linear Load)≦ 5 % THD (Non-linear Load)

Waveform (Batt. Mode)

Battery Mode 86%

1 A 2 A 2 A

8 A4 A 12 A

50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz46~54Hz or 56~64Hz

Pure SinewaveZeroZero

20 pcs(18 - 20 pcs adjustable)*

20pcs(18-20pcsadjustable)*x3 strings20 pcs (18 - 20 pcs adjustable)* x 2 strings

Back to 90% capacity in 9 hours

89% 90%88% 87% 89%

Battery TypeLong-Run Model Numbers

Charging Current (Max.)Charging Voltage 273 VDC ± 1% (Based on 20pcs batteries)

UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions

Depending on the applicationDepending on the application

273 VDC ± 1% (Based on 20pcs batteries)

208/220/230/240VACOutput Voltage

592 ×250 × 576164

40

815 × 250 × 826

592 x 250 x 576234

64

815 × 300 × 1000

815 × 250 × 826

0-95 % RH @ 0- 40°C (Non-condensing)Less than 60dB @1 MeterLess than 58dB @ 1 MeterNoise Level

Humidity

Smart RS-232 / USB

592 x 250 x 57683

28

Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MAC

Dimension (mm) D x W × HNet Weight (kgs)Dimension (mm) D × W × HNet Weight (kgs)

Standard Model

Long-Run Model

Full Specifications

Page 24: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

22

Online UPS

Master Series (3P/1P) - Tower

Online Master E Series 10kVA – 30kVA

• True double-conversion• DSP technology guarantees high performance• Output power factor 0.9• Wide input voltage range (110-300 VAC)• Active power factor correction in all phases• Built-in phase auto adapt function simplifies wire installation• 50Hz/60Hz frequency converter mode• ECO mode operation for energy saving• Programmable power management outlets

• Emergency power off function (EPO)• Generator compatible• SNMP+USB+RS-232 multiple communications• 3-stage extendable charging design for optimized battery performance• Adjustable battery numbers• Maintenance bypass available• Optional N+X parallel redundancy• Optional isolation transformer available

DataCentre

Electro-MedicalDevice

StoragePLCS

EmergencyAlarm

Devices

E-Business(Server Farms,ISP/ASP/POP)

Local AreaNetwork

(LAN)

TelecommunicationDevices

PRO83110ES/ELPRO83110ELI

Rear PanelFor 10kVA model1. RS-232 communication port2. USB communication port3. Emergency power off function connector (EPO connector)4. Share current port (only available for parallel model)5. Parallel port (only available for parallel model)6. Intelligent slot7. Charger fan8. Power stage fan9. Maintenance by-pass switch10. Input circuit breaker11. Output circuit breaker for receptacles12. Output receptacles: connect to mission-critical loads13. Input/Output terminal14. External battery connector (Only available for Long-run Model)

5 5

13

14

12

10

7

8

8

9

61 2 3 4

11

Master E Series (3P/1P) three-phase input / single-phase output, true online double conversion UPS system guarantees consistent and quality electrical power to protect your mission critical applications such as mid-sized business servers, telecommunication systems and industrial equipment. The (3P/1P) UPS is designed with a wide input voltage range to handle voltagefluctuating situations and a high accuracy output voltage to fail-safe your equipment. TheE-Series provides better output power factor of up to 0.9; offering high performance and efficiency for your critical applications.

By adopting the latest IGBT technology, this device is able offer excellent voltage switching characteristics during generator operation. In addition, this device comes with a parallelredundant system that allows two UPS models to operate in parallel and as backup for each other. The Master series (3P/1P) UPS also offers the option of adding on an isolation transformer to suit your requirements.

0.9Output Power

Factor

Page 25: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

23

Online UPS

PRO83115ES/ EL PRO83120ES/ ELPRO83120ELI

PRO83130ES/ EL

For 15kVA to 30kVA model1. RS-232 communication port2. USB communication port3. Emergency power off function connector (EPO connector)4. Share current port (only available for parallel model)5. Parallel port (only available for parallel model)6. Intelligent slot7. Charger fan8. Power stage fan9. Maintenance by-pass switch10. Input circuit breaker11. Output circuit breaker for receptacles12. Output receptacles: connect to mission-critical loads13. Input/Output terminal14. Output Terminal: Connect to mission-critical loads15. Programmable Output terminal: Connect to non-critical loads16. External battery terminal (only available for Long-run model)17. Utility input terminal18. Grounding terminal (only available for parallel system)

5 5

11

18

10

7

78

8

9

61 2 3 4

5 5

11

10

7

78

8

9

61 2 3 4

For 15K & 30K modelFor 10K model

14 15 1715 16 1714

18

• AS-400 Card (External alarm indicator)• SNMP Card for data communication via network connection• MODBUS Card (Communication interface)• Output Isolation Transformer (Available only for PRO83110ELI & PRO83120ELI)

Options

Page 26: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

24

Online UPS

L stands for Long-run modelS stands for Standard modelI stands for Isolation Transformer (Optional)*All specifications, designs and contents are subject to change without prior notice.

46 ~ 54Hz or 56 ~ 64Hz190-520 VAC (3-phase) at 50% load ; 305-478 VAC (3-phase) at 100% load

3 x 400VAC (3Ph+N)

3-phase in / 1-phase out

Nominal Voltage

Phase

Voltage RangeFrequency RangePower FactorTHDi

≧ 0.99 @ 100% load< 6% @ 100% load

Capacity 10kVA 10kVA 15kVA

12 V / 9 AhBattery Type

Numbers

AC Mode to Batt. ModeInverter to Bypass

Recharge Time (Typical)

Charging Current (Max.)Charging Voltage

Standard Model

Sounding twice every secondSounding twice every second

Continously sounding

INPUT

MODELS PRO83110ES/ EL PRO83110ELI PRO83115ES/ EL

20kVA 20kVA 30kVA

PRO83120ES/ EL PRO83120ELI PRO83130ES/ EL

OUTPUT

BATTERY

MANAGEMENT

ENVIRONMENT

PHYSICAL

INDICATORS

ALARM

EFFICIENCY

Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MACPower management from SNMP manager and web browser

Smart RS-232 / USBOptional SNMP

Sounding every 4 secondsBattery ModeLow Battery

LCD Display

OverloadFault

AC Mode

±1%

3.1

Voltage Regulation (Batt. Mode)

Frequency Range (Batt. Mode)Frequency Range (Synchronized Range)

Current Crest Ratio

Harmonic Distortion

Transfer Time

≦2 % THD(Linear Load)≦5 % THD

(Non-linear Load)

≦2 % THD(Linear Load)≦6% THD

(Non-linear Load)

≦2 % THD(Linear Load)≦7% THD

(Non-linear Load)

≦2 % THD(Linear Load)≦5% THD

(Non-linear Load)

≦ 2 % THD (Linear Load)≦ 5 % THD (Non-linear Load)

ZeroZero

Waveform (Batt. Mode)

Battery Mode

1A 2A 2A

8A4A 12A

50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz46~54Hz or 56~64Hz

Pure Sinewave

20 pcs (18 - 20 pcs adjustable)* x 2 strings20 pcs (18 - 20 pcs adjustable)*

Back to 90% capacity in 9 hours Back to 90%capacity in 9 hours

20pcs(18-20pcsadjustable)x3 strings

Not Applicable

Not Applicable

91% 87% 91%91% 85%88% 87% 83% 88%86% 83%

Battery Type

Long-Run Model Charging Current (Max.)Numbers

Charging Voltage

UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions

Depending on the application

273 VDC ± 1% (Based on 20pcs batteries)

Depending on the application273 VDC ± 1% (Based on 20pcs batteries)

208/220/230/240VAC

208/220/230/240VAC208/220/230/240VAC

104/110/115/120VAC or 208/

220/230/240VAC

104/110/115/120VAC or 208/

220/230/240VACOutput Voltage

592 ×250 × 576164

40

815 × 250 × 826

592 x 250 x 576141

144

91592 x 250 x 826

234

64

815 × 300 × 1000

815 × 250 × 826

0 - 95% RH @ 0 - 40°C (Non-condensing)

Less than 58dB @ 1 Meter Less than 60dB @ 1 MeterNoise Level

Humidity

592 x 250 x 576 592 x 250 x 82683

28

Dimension (mm) D x W × HNet Weight (kgs)Dimension (mm) D × W × HNet Weight (kgs)

Standard Model

Long-Run Model

Full Specifications

Page 27: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

25

Online UPS

Master Series (3P/1P) - Rack Mount

Online Master Series 10kVA – 20kVA

• True double-conversion• DSP technology guarantees high performance• Output power factor 0.8• Wide input voltage range (110-300 VAC)• Active power factor correction in all phases• Built-in phase auto adapt function simplifies wire installation• 50Hz/60Hz frequency converter mode

• ECO mode operation for energy saving• Emergency power off function (EPO)• Generator compatible• SNMP/USB+RS-232 multiple communications (SNMP is optional)• 3-stage extendable charging design for optimized battery performance• Adjustable battery numbers• Optional N+X parallel redundancy

Master Series (3P/1P) – Rack three-phase input / single-phase output, true online double conversion UPS systemguarantees consistent and quality electrical power to protect your mission critical applications such as mid-sizedbusiness servers, telecommunication systems and industrial equipments. This (3P/1P) UPS is designed with a wide input voltage range to handle voltage fluctuating situations and a high accuracy output voltage to fail-safe yourequipment.

This Voltage Frequency Independent (VFI) system is available in capacities from 10kVA to 20kVA. By adopting the latest IGBT technology, this device is able offer excellent voltage switching characteristics during generator operation. Aninternal bypass system allowing continuous power is also integrated for convenience when maintenance is necessary. In addition, this device comes with a parallel redundant system that allows two UPS models to operate in parallel and as backup for each other. The Master series (3P/1P) – Rack UPS also offers the option of adding on an isolation transformer to suit your requirements.

DataCentre

19” RackMount

StoragePLCS

EmergencyAlarm

Devices

Local AreaNetwork

(LAN)

TelecommunicationDevices

5

12 10

7 8

9

6 6

1

2

3

4 4 4

11

5

12

10

7

8

9

6 6

6 6

1

23

4

4

411

Rear PanelFor 10kVA to 20kVA model1. RS-232 communication port2. USB communication port3. Emergency power off function connector (EPO connector)4. Parallel port (only available for parallel model)5. Intelligent slot6. Fan7. External maintenance by-pass switch connection8. Input circuit breaker9. Input/Output terminal10. Output terminal11. Battery terminal12. Input terminal

PRO83110RS/RL

PRO83115RS/ RL PRO83120RS/RL

Page 28: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

26

Online UPS

• AS-400 Card (External Alarm Indicator)• SNMP Card for data communication via network connection• MODBUS Card (Communication interface)• Universal Rackmount Slider for installation in rack cabinets• External Maintenance Bypass Switch (Only available with 10kVA model)

Options

Full Specifications

46~54 Hz or 56~64Hz190-520 VAC (3-phase) at 50% load ; 305-478 VAC (3-phase) at 100% load

3 x 400 VAC (3Ph+N)

3-phase in / 1-phase out

Nominal VoltageVoltage Range

Capacity

Frequency RangePower FactorTHDi

≧ 0.99 @ 100% Load< 6% @ 100% Load

Phase10kVA 20kVA

12 V / 9 AhBattery TypeNumbersRecharge Time (Typical)Charging Current (Max.)Charging Voltage

Standard Model

Sounding twice every secondSounding every second

Continously sounding

Power management from SNMP manager and web browserSupports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MAC

Optional SNMP

INPUT

MODELS PRO83110RS/ RL

15kVA

PRO83115RS/ RL PRO83120RS/ RL

OUTPUT

BATTERY

MANAGEMENT

ENVIRONMENT

PHYSICAL

INDICATORS

ALARM

EFFICIENCY

Sounding every 4 secondsBattery ModeLow Battery

LCD Display

OverloadFault

AC Mode

±1%

3:1

AC Voltage Regulation (Batt. Mode)

Frequency Range (Batt. Mode)Frequency Range (Synchronized Range)

Current Crest RatioHarmonic Distortion

Transfer Time AC Mode to Batt. ModeInverter to Bypass Zero

Zero

Waveform (Batt. Mode)

Battery Mode

1A 2A

50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz46~54Hz or 56~64Hz

Pure Sinewave

20 (18 - 20 adjustable) 20 pcs x 2 strings (18 - 20 adjustable)Back to 90% capacity in 9 hours

89%87%86% 88%

≦ 2 % THD (Linear Load) ; ≦ 5 % THD (Non-linear Load)

Battery TypeLong-Run Model Numbers

Charging Current (Max.)Charging Voltage

UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions

4A273 VDC ± 1% (based on battery numbers at 20 pcs)

Depending on the capacity of external batteries

273 VDC ± 1% (based on battery numbers at 20 pcs)

208/220/230/240VACOutput Voltage

668 x 438 x 133 (3U)

UPS Unit: 668 x 438 x 266 (6U)BatteryPack: 580 x 438 x 133 (3U) x 2PCS

668 x 438 x 266 (6U)

Noise Level0-95 % RH @ 0- 40°C (Non-condensing)Operation Humidity

Less than 60dB @ 1 Meter Less than 65dB @ 1 Meter

Smart RS-232 / USB

UPS Unit: 668 x 438 x 133 (3U)Battery Pack: 580 x 438 x 133 (3U)

UPS unit: 22Battery pack: 63

UPS unit: 45Battery pack: 63 x 2PCS

22 45

Dimension (mm) D x W × H

Net Weight (kgs)

Dimension (mm) D × W × HNet Weight (kgs)

Standard Model

Long-Run Model

L stands for Long-run modelS stands for Standard model*All specifications, designs and contents are subject to change without prior notice.

Page 29: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

27

Online UPS

Master Series (3P/3P) - Tower

Online Master Series 10kVA – 30kVA

• True double-conversion• DSP technology guarantees high performance• Output power factor 0.8• Active power factor correction in all phases• 50Hz/60Hz frequency converter mode• ECO mode operation for energy saving• Accepts dual-mains inputs (only available for dual input unit)• Emergency power off function (EPO)• Generator compatible

DataCentre

Electro-MedicalDevice

StoragePLCS

EmergencyAlarm

Devices

E-Business(Server Farms,ISP/ASP/POP)

Local AreaNetwork

(LAN)

TelecommunicationDevices

Master Series (3P/3P) – Tower three-phase input / three-phase output, true online double conversion UPS system guarantees consistent and quality electrical power to protect your mission critical applications such as small server room, medical devices, telecommunication facilities and industrial processes. This (3P/3P) UPS is designed with a wide input voltage range to handle voltage fluctuating situations and a high accuracy output voltage to fail-safe your equipment.

The Master Series (3P/3P) UPS system is available in capacities from 10kVA to 30kVA. By adopting the latest IGBT technology, this device is able offer excellent voltage-switching characteristics during generator operation. An internal bypass system allowing continuous power is also integrated for convenience whenmaintenance is necessary. In addition, this device comes with a parallel redundant system that allows two UPS models to operate in parallel and as backup for each other. The Tower series UPS also offers the option of adding on an isolationtransformer to suit your requirements.

Rear PanelFor 10kVA to 30kVA model1. RS-232 communication port2. USB communication port3. Emergency power off function connector (EPO connector)4. Share current port (only available for parallel model)5. Parallel port (only available for parallel model)6. Intelligent slot7. Charger fan8. Power stage fan9. Maintenance bypass switch10. Bypass Input Circuit Breaker (Only available for dual input unit)11. Input circuit breaker12. Input/Output terminal13. External battery terminal (only available for Long-run model)

12

10 13

7

7

68

8

9

1 2 3 4

11

5

PRO83310S/LPRO83320S/LPRO83330S/L

• SNMP/USB+RS-232 multiple communications (SNMP is optional)• 3-stage extendable charging design for optimized battery performance• Adjustable battery numbers• Maintenance bypass available• Optional N+X parallel redundancy• Optional isolation transformer offers full isolation and complete common mode noise rejection

Page 30: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

28

Online UPS

• AS-400 Card (External Alarm Indicator)• SNMP Card for data communication via network connection• MODBUS Card (Communication interface)• Output Isolation Transformer

Options

Full Specifications

46~54 Hz or 56~64Hz190-520 VAC (3-phase) at 50% load ; 305-478 VAC (3-phase) at 100% load

3 x 400 VAC (3Ph+N)Nominal VoltageInput Voltage Range

Capacity

Frequency RangePower Factor ≧ 0.99 @ 100% Load

Phase10kVA 30kVA

12 V / 9 AhBattery Type

Numbers

Recharge Time (Typical)Charging Current (Max.)Charging Voltage

Standard Model

Sounding twice every secondSounding every second

Continously sounding

Power management from SNMP manager and web browserOptional SNMP

INPUT

MODELS PRO83310S/ L PRO83330S/ L

20kVA3-phase in / 3-phase out

15kVA

PRO83320S/ LPRO83315S/ L

OUTPUT

BATTERY

MANAGEMENT

ENVIRONMENT

PHYSICAL

INDICATORS

Low Battery

ALARM

EFFICIENCY

Sounding every 4 secondsBattery Mode

LCD Display

OverloadFault

Battery ModeAC Mode

46~54Hz or 56~64Hz

≦ 2 % THD (Linear Load) ; ≦ 5 % THD (Non-linear Load)

Frequency Range (Synchronized Range)

Current Crest RatioFrequency Range (Batt. Mode)

Harmonic DistortionAC Mode to Batt. Mode

Transfer TimeInverter to Bypass

Waveform (Batt. Mode) Pure SinewaveZero

1A 2A 4A

3:1 (Max.)50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz

20 pcs(18 - 20 adjustable)* 20 pcs x 2 strings (18 - 20 adjustable)* 20pcs x 3 strings

(18-20 adjustable)*

Back to 90% capacity in 9 hours

88% 87% 89%86%89% 90%

Zero

Battery Type

Long-Run ModelCharging Current (Max.)Charging Voltage

Numbers12A4A

273 VDC ± 1%

UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault

Depending on the capacity of external batteries

273 VDC ± 1%

± 1%3 x 400 VAC (3Ph+N)

AC Voltage Regulation (Batt. Mode)Output Voltage

592 x 250 x 826

815 x 250 x 826

815 x 250 x 826

815 x 300 x 1000

Less than 65dB @ 1 MeterLess than 60dB @ 1 MeterNoise Level0-95 % RH @ 0- 40°C (Non-condensing)Humidity

Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MACSmart RS-232 / USB

233.5164109

38 40 64

Dimension (mm) D x W × HNet Weight (kgs)Dimension (mm) D × W × HNet Weight (kgs)

Standard Model

Long-Run Model

L stands for Long-run modelS stands for Standard modelI stands for Isolation Transformer (Optional)*All specifications, designs and contents are subject to change without prior notice.

Page 31: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

29

Online UPS

0.9Output Power

Factor

Master Series (3P/3P) - Tower

Online Master E Series 10kVA – 30kVA

• True double-conversion• DSP technology guarantees high performance• Output power factor 0.9• Active power factor correction in all phases• 50Hz/60Hz frequency converter mode• ECO mode operation for energy saving (ECO)• Accepts dual-mains inputs• Emergency power off function (EPO)

• Generator compatible• SNMP+USB+RS-232 multiple communications• 3-stage extendable charging design for optimized battery performance• Adjustable battery numbers• Maintenance bypass available• Optional N+X parallel redundancy

DataCentre

Electro-MedicalDevice

StoragePLCS

EmergencyAlarm

Devices

E-Business(Server Farms,ISP/ASP/POP)

Local AreaNetwork

(LAN)

TelecommunicationDevices

Master E Series (3P/3P) – Tower three-phase input / three-phase output, true online double conversion UPS system guarantees consistent and quality electrical power to protect your mission critical applications such as small server room, medical devices,telecommunication facilities and industrial processes. This (3P/3P) UPS is designed with a wide input voltage range to handle voltage fluctuating situations and a high accuracy output voltage to fail-safe your equipment.

The Master E Series (3P/3P) UPS system is available in capacities from 10kVA to 30kVA. By adopting the latest IGBT technology, this device is able offer excellentvoltage-switching characteristics during generator operation. An internal bypass system allowing continuous power is also integrated for convenience when maintenance is necessary. In addition, this device comes with a parallel redundant system that allows two UPS models to operate in parallel and as backup for each other. The Tower series UPS also offers the option of adding on an isolation transformer to suit yourrequirements.

Rear PanelFor 10kVA to 30kVA model1. RS-232 communication port2. USB communication port3. Emergency power off function connector (EPO connector)4. Share current port (only available for parallel model)5. Parallel port (only available for parallel model)6. Intelligent slot7. Charger fan8. Power stage fan9. Maintenance bypass switch10. Bypass Input Circuit Breaker (Only available for dual input unit)11. Input circuit breaker12. Input/Output terminal13. External battery terminal (only available for Long-run model)

12

10 13

7

7

68

8

9

1 2 3 4

11

5

PRO83310ES/ELPRO83320ES/ELPRO83330ES/EL

Page 32: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

30

Online UPS

• AS-400 Card (External Alarm Indicator)• SNMP Card for data communication via network connection• MODBUS Card (Communication interface)• Output Isolation Transformer

Options

Full Specifications

L stands for Long-run modelS stands for Standard modelI stands for Isolation Transformer (Optional)*All specifications, designs and contents are subject to change without prior notice.

46~54 Hz or 56~64Hz190-520 VAC (3-phase) at 50% load ; 305-478 VAC (3-phase) at 100% load

3 x 400 VAC (3Ph+N)Nominal VoltageInput Voltage Range

Capacity

Frequency RangePower Factor ≧ 0.99 @ 100% Load

Phase10kVA 30kVA

12 V / 9 AhBattery Type

Numbers

Recharge Time (Typical)Charging Current (Max.)Charging Voltage

Standard Model

Sounding twice every secondSounding every second

Continously sounding

Power management from SNMP manager and web browserOptional SNMP

INPUT

MODELS PRO83310ES/ EL PRO83330ES/ EL

20kVA3-phase in / 3-phase out

15kVA

PRO83320ES/ ELPRO83315ES/ EL

OUTPUT

BATTERY

MANAGEMENT

ENVIRONMENT

PHYSICAL

INDICATORS

Low Battery

ALARM

EFFICIENCY

Sounding every 4 secondsBattery Mode

LCD Display

OverloadFault

Battery ModeAC Mode

46~54Hz or 56~64Hz

≦ 2 % THD (Linear Load) ; ≦ 5 % THD (Non-linear Load)

Frequency Range (Synchronized Range)

Current Crest RatioFrequency Range (Batt. Mode)

Harmonic DistortionAC Mode to Batt. Mode

Transfer TimeInverter to Bypass

Waveform (Batt. Mode) Pure SinewaveZero

1A 2A 4A

3:1 (Max.)50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz

20 pcs(18 - 20 adjustable)* 20 pcs x 2 strings (18 - 20 adjustable)* 20pcs x 3 strings

(18-20 adjustable)*

Back to 90% capacity in 9 hours

88% 87% 89%86%89% 90%

Zero

Battery Type

Long-Run ModelCharging Current (Max.)Charging Voltage

Numbers12A4A

273 VDC ± 1%

UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault

Depending on the capacity of external batteries

273 VDC ± 1%

± 1%3 x 400 VAC (3Ph+N)

AC Voltage Regulation (Batt. Mode)Output Voltage

592 x 250 x 826

815 x 250 x 826

815 x 250 x 826

815 x 300 x 1000

Less than 65dB @ 1 MeterLess than 60dB @ 1 MeterNoise Level0-95 % RH @ 0- 40°C (Non-condensing)Humidity

Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MACSmart RS-232 / USB

233.5164109

38 40 64

Dimension (mm) D x W × HNet Weight (kgs)Dimension (mm) D × W × HNet Weight (kgs)

Standard Model

Long-Run Model

Page 33: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

31

Online UPS

Power Series

Online Power Series 15kVA – 120kVA

• Online double conversion technology with DSP control• Advanced control with Adaptive Feed Forward Cancellation (AFC) technology for very low harmonic distortion• Very low input current distortion (THDi < 1%)• Input power factor 0.99 at 10% load• Output efficiency up to 95%• Space-saving compact design• Front access makes maintenance and replacement easily• Highly flexibility in single phase/three-phase set-ups

• Control designed to withstand all kinds of loads• Parallel redundant operation with up to 4 units• Variety of communication options available• Over 60% mateirals recyclable• Remaining backup time calculation• 5.7" graphic LCD panel design with multiple languates for easy-configuration• Optional touch panel design for 5.7" LCD

DataCentre

Electro-MedicalDevice

StoragePLCS

EmergencyAlarm

Devices

E-Business(Server Farms,ISP/ASP/POP)

Local AreaNetwork

(LAN)

TelecommunicationDevices

Power Series (3P/3P) three-phase input / three-phase output, true online doubleconversion UPS system guarantees to supply consistent and quality electrical power to protect your mission critical applications such as data centres, medical equipments and call centres. Harmful effects of harmonic injection areeliminated with the employment of Adaptive Feed Forward Cancellation (AFC) technology. With a UPS system that reflects low harmonic distortion and high input power factor, it is able to lower installation costs by utilizing smaller cables and miniature circuit breakers (MCB).

Our team of specialists has gathered together to revolutionize the UPS usability by adding in a 5.7” LCD monitor display with all information and alarmnotifications viewable within a single display. To ensure our products are user centered, our group of specialist has also adopted a front access concept to create a UPS system that is easy for users to carry out preventativemaintenance and replacement activities. In addition, this device comes with a parallel redundant system that allows four UPS models to operate in parallel. An option of an additional isolation transformer is also available to suit yourrequirements. The Power series is available in models ranging from 15kVA to 120kVA.

Rear Panel (Internal)For 15kVA to 80kVA model1. Relay interface2. Emergency Power Off (EPO)3. RS-232 COM ports4. Intelligent Slow5. Input circuit breaker6. Maintenance bypass switch7. Output switch8. Battery switch9. System Terminal10. Parallel port (only available for parallel model)

5

10

76

9

12

3

8

4

PRO73315S/SIPRO73320S/SI

PRO73330S/SIPRO73340S/SI

5

10

76

9

12

3

8

4

PRO73360S/SIPRO73380S/SI

5

10

76

9

12

3

8

4

Page 34: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

32

Online UPS

PRO733100SPRO733120S

Full Specifications

For 100kVA to 120kVA model1. Relay interface2. Emergency Power Off (EPO)3. RS-232 COM ports4. Intelligent Slow5. Input circuit breaker6. Maintenance bypass switch7. Output switch8. Battery switch9. System Terminal10. Parallel port (only available for parallel model)

5

10

76

9

12

3

8

4

If the UPS is installed in a location where the altitude is above 1000m, the output power must be lowered by one percent for every 100m covered. L stands for Long-run modelS stands for Standard modelI stands for Isolation Transformer (Optional)*All specifications, designs and contents are subject to change without prior notice.

50/60 Hz ± 5 %+15% or –20%

3 x 400V (3Ph + N)Nominal VoltageAcceptable Voltage RangeFrequency

Total Harmonic Distortion (THDi)

Current Limitation

< 1.5% @ 100% load< 2.5% @ 50% load< 6.0% @ 10% load

< 1.0% @ 100% load< 2.0% @ 50% load< 5.0% @ 10% load

High overload: PFC Limit (discharging batteries)Power Factor 1.0

Capacity 15kVA 60kVA

50/60 HzFrequencyActivation CriterionTransfer TimeAdmissible Overload

110 180 210 230Net Weight (W/O batteries) (Kg)

INPUT

MODELS PRO73315S/ SI20kVA

PRO73320S/ SI30kVA

PRO73330S/ SI40kVA

PRO73340S/ SI PRO73360S/ SI80kVA

PRO73380S/ SI

INVERTER

Voltage

Net Weight (w/built-in batteries) (Kg)

Built-in Battery Type (2x31)

Frequency

Transfer to Bypass

STATIC BYPASS

280 300 430 565

3 x 400V (3Ph + N)50/60 Hz

Voltage

Retransfer

Type

Stationary: ±1% ; Transitory: ±2% (load variations 100-0-100%)50/60 Hz synchronised ±4 % With mains absent ±0.05%

120º ±1% (balanced load) ; 120º ±2% (imbalances 50% of the load)

PrecisionFrequency

WaveformTotal Harmonic Distortion (THDv)

Max. Synchronisation Speed

Phase DisplacementDynamic Recovery TimeAdmissible OverloadAdmissible Crest Factor 3.2 :1 2.8 : 13.4 : 1

125% for 10 min., 150% for 60 s

Admissible Power FactorImbalance Output Voltage @ 100% Unbalanced Load <1%

0.7 inductive to 0.7 capacitive

Current Limit

400% for 10 sec.Immediate, for overloads above 150%

Pure Sinewave<0.5% (Linear Load) ; <1.5% (Non-linear Load)

±10 Hz/s

High overload, short-circuit: RMS Voltage Limit ; High Crest-Factor current: Peak Voltage Limit

Microprocessor controlZero

Solid state3x400V (3Ph + N)

10 ms. at 98 % of the static value

Automatic after alarm clearMAINTENANCE BYPASSType Without interruption

3 x 400V (3Ph + N)Nominal Voltage

90.5%

12V 4.5Ah 12V 9Ah 12V 12Ah 12V 18AhNot Applicable

Not Applicable

91% 92% 92.5% 93% 94%

23.5 A 47 A 70.5 AMax. Charging Current10 9 8 7Back-up Time (minutes)

PHYSICAL700 x 450 x 1100 805 x 590 x 1320Dimensions, D x W x H(mm)

Overall Efficiency (Line mode)BATTERY

Page 35: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

33

Online UPS

If the UPS is installed in a location where the altitude is above 1000m, the output power must be lowered by one percent for every 100m covered. L stands for Long-run modelS stands for Standard modelI stands for Isolation Transformer (Optional)*All specifications, designs and contents are subject to change without prior notice.

• SNMP Card for data communication via network connection• MODBUS Card (Communication interface)• Output Isolation Transformer

Options

50/60 Hz ± 5 %+15% or –20%

3 x 400V (3Ph + N)Nominal VoltageAcceptable Voltage RangeFrequency

Total Harmonic Distortion (THDi)

Current Limitation

< 1.0% @ 100% load< 2.0% @ 50% load< 5.0% @ 10% load

High overload: PFC Limit (discharging batteries)Power Factor 1.0

Capacity 120kVA

50/60 HzFrequencyActivation CriterionTransfer TimeAdmissible Overload

255Net Weight (W/O batteries) (Kg)

INPUT

MODELS100kVA

PRO733100S PRO733120S

INVERTER

Voltage

Net Weight (w/built-in batteries) (Kg)

Frequency

Transfer to Bypass

STATIC BYPASS

3 x 400V (3Ph + N)50/60 Hz

Voltage

Retransfer

Type

Stationary: ±1% ; Transitory: ±2% (load variations 100-0-100%)50/60 Hz synchronised ±4 % With mains absent ±0.05%

120º ±1% (balanced load) ; 120º ±2% (imbalances 50% of the load)

PrecisionFrequency

WaveformTotal Harmonic Distortion (THDv)

Max. Synchronisation Speed

Phase DisplacementDynamic Recovery TimeAdmissible OverloadAdmissible Crest Factor 3.2 :1

125% for 10 min., 150% for 60 s

Admissible Power FactorImbalance Output Voltage @ 100% Unbalanced Load <1%

0.7 inductive to 0.7 capacitive

Current Limit

400% for 10 sec.Immediate, for overloads above 150%

Pure Sinewave<0.5% (Linear Load) ; <1.5% (Non-linear Load)

±10 Hz/s

High overload, short-circuit: RMS Voltage Limit ; High Crest-Factor current: Peak Voltage Limit

Microprocessor controlZero

Solid state3x400V (3Ph + N)

10 ms. at 98 % of the static value

Automatic after alarm clearMAINTENANCE BYPASSType Without interruption

3 x 400V (3Ph + N)Nominal Voltage

Not Applicable

93% 93.3%

188 AMax. Charging CurrentPHYSICAL

805 x 590 x 1320Dimensions, D x W x H(mm)

Overall Efficiency (Line mode)BATTERY

Page 36: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

34

Online UPS

The Most Versatile Solution For PowerProtectionThe Power Series is designed with the new state of art transformerless PWM technology that can be easily adapted to any kinds of complicated loads such as the non-linear systems (IT systems), highly inductive/capacitive loads, high-density discharge lamps and induction motors. The Power series is designed with 2 important criterions in mind; maximum efficiency and energy conservation. The unit also comes with a small form factor to allow for minimum installation effort. Furthermore, a parallel redundant system is integrated to allow two UPS models to operate in parallel as backup for each other. The Power Series is available incapacities ranging from 15 to 120kVA.

Online Double Conversion Technology with DSP ControlThe Power Series is able provide a higher load up-time and effective insulation against network disturbance with its online double conversion technology. A Digital Signal Processor (DSP) controller improves theperformance and efficiency of the UPS.

Advanced Control with Adaptive Feed Forward Cancellation (AFC) TechnologyBy cancelling both the input current and the output voltage harmonics, the harmful effects of harmonic injection can be eliminated and this enhances the load integrity.

Low Input Current Distortion (THDi < 1%)AFC cells are used to achieve extremely low distortion values. The Power series is able to obtain a low input current distortion at THDi < 1% under full load and a THDi < 5% under smaller load (i.e. 10% of load). This will prevent distortion of electrical network upstream and thus, result in the reduction of cable usage and protective devices in the electrical network.

Input Power Factor 0.99 At 10% LoadLower power losses would result in reducedconsumption, lower operation and maintenance costs.

Output Efficiency of up to 95%Designed with a DSP controller and fourth generation IGBT transistors, the UPS is able to achieve extremely high efficiency of up to 95%. With such high ratings, components in the UPS are not only protected but also prolonged due to the decrease in heat losses.

Small Form FactorUtilizes a transformerless technology allows the design of the UPS to be lighter and smaller.

1,20

1,00

0,80

0,60

0,40

0,20

0,000% 25% 50%

LOAD

INPUT POWER FACTOR

PFin

100%

75%

50%

25%

0%0%

SERIES TIPICAL EFFICIENCY

25% 50%

EFFI

CIEN

CY

LOAD

Page 37: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

35

Online UPS

An important consideration has been given during the UPS design phase to create a system that allows users to access theunit’s electronic cards and powercomponents with minimum effort. All electronic boards and components can be accessed from the front panel for easy maintenance and replacement activities.

Versatile Single-Phase / Three-Phase set-upsThis highly versatile UPS is designed with different types of setting-up options;• Three-phase input / Three-phase output (III/III) • Three-phase input / Single phase output (III/I)

Control Components are designed to with stand all kinds of loadsIn the Power Series, the control components are designed to withstand all types of loads. These include loads such as; resistive, capacitive, non-linear,high-density discharge lamps, induction motors, speed drives etc. This makes the UPS extremely compatible with many types of electronics. Better yet, the UPS comes with a wide array of parameters that can be programmed locally or remotely to fit different types of environment.

N+1 RedundancyA parallel redundant system allows 4 UPS models to operate in parallel and as backup for each other.

Variety Of Communications And OptionAvailableThe UPS has provided the following standardcommunication selections:• Relay interface• RS-232/485 port• 1 × SNMP slot• Modbus RTU / SEC protocol• 2 × connectors for parallel connection

Made of 60% RecyclableMaterialsWhen it comes to conserving the environment, PROLiNK is committed to play a part by designing their UPS products using recyclable materials.

Back-up Time indicatorWith the use of simple algorithms, an estimatedremaining back-up time can be calculated andindications will be reflected on a LCD panel.

5.7” Multiple Languages Graphical LCDDisplayOur team of specialists has gathered together torevolutionize the UPS usability by adding in a 5.7” LCD monitor display with all information and alarmnotifications viewable within a single display.

Page 38: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

36

Online UPS

Power Series

Online Power E Series 10kVA – 120kVA

• Online double conversion technology with DSP control• Output power factor 0.9• Advanced control with Adaptive Feed Forward Cancellation (AFC) technology for very low• Very low input current distortion (THDi < 1%)• Input power factor 0.99 at 10% load• Output efficiency up to 95%• Space-saving compact design• Over 60% materials recyclable• Remaining backup time calculation

• Remaining backup time calculation• Front access makes maintenance and replacement easily• Highly flexibility in single phase/ three-phase set-ups• Parallel redundant operation with up to 4 units• Variety of communications and options available• Flexible battery type configuration by request (only available for Taurus Pro 400V models)• Long-run models available for 400V 10KVA-40KVA and 208V 7.5KVA-20KVA

DataCentre

Electro-MedicalDevice

StoragePLCS

EmergencyAlarm

Devices

E-Business(Server Farms,ISP/ASP/POP)

Local AreaNetwork

(LAN)

TelecommunicationDevices

PROLiNK UPS Power E Series (3P/3P) three-phase input / three-phase output, true online double conversion UPS system guarantees to supply consistent and quality electrical power to protect your mission critical applications such as data centres, medical equipments and call centres. Power E Series give excellent output leading power factor up to 0.9 leading for 100% load. Harmful effects of harmonic injection are eliminated with the employment of Adaptive Feed Forward Cancellation (AFC) technology. With a UPS system that reflects low harmonic distortion and high input power factor, it is able to lower installation costs by utilizing smaller cables and miniature circuit breakers (MCB).

Our team of specialists has gathered together to revolutionize the UPS usability by adding in a 5.7” LCD monitor display with all information and alarm notifications viewable within a single display. To ensure our products are user centered, our group of specialist has also adopted a front access concept to create a UPS system that is easy for users to carry out preventative maintenance and replacement activities. In addition, this device comes with a parallelredundant system that allows four UPS models to operate in parallel. An option of anadditional isolation transformer is also available to suit your requirements. The Power series is available in models ranging from 10kVA to 120kVA.

Rear Panel (Internal)For 10kVA to 80kVA model1. Relay interface2. Emergency Power Off (EPO)3. RS-232 COM ports4. Intelligent Slow5. Input circuit breaker6. Maintenance bypass switch7. Output switch8. Battery switch9. System Terminal10. Parallel port (only available for parallel model)

5

10

76

9

12

3

8

4

PRO73310ESPRO73315ESPRO73320ES

PRO73330ESPRO73340ES

5

10

76

9

12

3

8

4

PRO73360ESPRO73380ES

5

10

76

9

12

3

8

4

Page 39: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

37

Online UPS

PRO733100ESPRO733120ES

Full Specifications

50 / 60 Hz ±5 %+15% or –20%

3 x 400V (3Ph + N)Nominal VoltageAcceptable Voltage Range

Capacity

FrequencyCurrent LimitationPower Factor

High overload: PFC Limit (discharging batteries)1.0

Total Harmonic Distortion (THDi)< 1.5% @ 100% load;< 2.5% @ 50% load;< 6.0% @ 10% load

< 1.0% @ 100% load;< 2.0% @ 50% load;< 5.0% @ 10% load

Phase

50/60 HzFrequencyActivation Criterion

Current Limit

Transfer TimeAdmissible Overload

78 86 94 110 122 162 231Net Weight (without batteries) (kgs)

INPUT

MODELS PRO73315ESPRO73310ES PRO73320ES3-phase in / 3-phase out

PRO73330ES PRO73340ES PRO73360ES

15kVA 60kVA10kVA 20kVA 30kVA 40kVA 80kVA

PRO73380ES

INVERTER

Voltage

Net Weight (w/built-in batteries) (kgs)

Built-in Battery Type (2x31)

Frequency

Transfer to Bypass

STATIC BYPASS

178 186 249 290 357 Not Applicable

Not Applicable

3 x 400V (3Ph + N)50/60 Hz

Voltage

Retransfer

Type

Stationary: ±1% ; Transitory: ±2% (load variations 100-0-100%)50/60 Hz synchronised ±4 % With mains absent ±0.05%

< 0.5% (Linear Load) ; < 1.5% (Non-linear Load)

PrecisionFrequency

WaveformMax. Synchronisation Speed

Total Harmonic Distortion (THDv)Phase DisplacementDynamic Recovery Time

Phase Overload: 125% for 10 min., 150% for 60s ; Total Overload: 112.5% for 10 min., 135% for 60s10 ms. at 98 % of the static value

Admissible Crest FactorAdmissible Power Factor

Admissible Overload

0.7 inductive to 0.7 capacitive

<1%

3.4 : 1 3.2 :1 2.8 : 1

Imbalance Output Voltage@ 100%Unbalanced Load

400% for 10 sec.Immediate, for overloads above 150%

Pure Sinewave±10 Hz/s

High overload, short-circuit: RMS Voltage Limit ; High Crest-Factor current: Peak Voltage Limit

Microprocessor controlZero

Solid state3x400V (3Ph + N)

120º ±1% (balanced load) ; 120º ±2% (imbalances 50% of the load)

Automatic after alarm clearMAINTENANCE BYPASSType Without interruption

3 x 400V (3Ph + N)Nominal Voltage

90% 90.5% 91% 92%

12V 4.5Ah5 3 5

12V 4.5Ah 12V 7Ah 12V 9Ah 12V 12Ah

93%92.5% 94%

23.5 A 47 A 70.5 AMax. Charging Current33Back-up Time (minutes)

PHYSICAL770 x 450 x 1100 805 x 590 x 1320Dimension (mm) D x W x H

Overall Efficiency (Line mode)BATTERY

For 100kVA to 120kVA model1. Relay interface2. Emergency Power Off (EPO)3. RS-232 COM ports4. Intelligent Slow5. Input circuit breaker6. Maintenance bypass switch7. Output switch8. Battery switch9. System Terminal10. Parallel port (only available for parallel model)

5

10

76

9

12

3

8

4

If the UPS is installed in a location where the altitude is above 1000m, the output power must be lowered by one percent for every 100m covered. L stands for Long-run modelS stands for Standard modelI stands for Isolation Transformer (Optional)*All specifications, designs and contents are subject to change without prior notice.

Page 40: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

38

Online UPS

• SNMP Card for data communication via network connection• MODBUS Card (Communication interface)• Output Isolation Transformer

Options

50 / 60 Hz ±5 %+15% or –20%

3 x 400V (3Ph + N)Nominal VoltageAcceptable Voltage Range

Capacity

FrequencyCurrent LimitationPower Factor

High overload: PFC Limit (discharging batteries)1.0

Total Harmonic Distortion (THDi)< 1.5% @ 100% load;< 2.0% @ 50% load;< 6.0% @ 10% load

Phase

50/60 HzFrequencyActivation Criterion

Current Limit

Transfer TimeAdmissible Overload

255Net Weight (without batteries) (kgs)

INPUT

MODELS PRO733100ES PRO733120ES

100kVA3-phase in / 3-phase out

120kVA

INVERTER

Voltage

Net Weight (w/built-in batteries) (kgs)

Frequency

Transfer to Bypass

STATIC BYPASS

Not Applicable

3 x 400V (3Ph + N)50/60 Hz

Voltage

Retransfer

Type

Stationary: ±1% ; Transitory: ±2% (load variations 100-0-100%)50/60 Hz synchronised ±4 % With mains absent ±0.05%

< 0.5% (Linear Load) ; < 1.5% (Non-linear Load)

PrecisionFrequency

WaveformMax. Synchronisation Speed

Total Harmonic Distortion (THDv)Phase DisplacementDynamic Recovery Time

Phase Overload: 125% for 10 min., 150% for 60s ; Total Overload: 112.5% for 10 min., 135% for 60s10 ms. at 98 % of the static value

Admissible Crest FactorAdmissible Power Factor

Admissible Overload

0.7 inductive to 0.7 capacitive

<1%

3.2 :1

Imbalance Output Voltage@ 100%Unbalanced Load

400% for 10 sec.Immediate, for overloads above 150%

Pure Sinewave±10 Hz/s

High overload, short-circuit: RMS Voltage Limit ; High Crest-Factor current: Peak Voltage Limit

Microprocessor controlZero

Solid state3x400V (3Ph + N)

120º ±1% (balanced load) ; 120º ±2% (imbalances 50% of the load)

Automatic after alarm clearMAINTENANCE BYPASSType Without interruption

3 x 400V (3Ph + N)Nominal Voltage

93.3%93%

70.5 A 188 AMax. Charging CurrentPHYSICAL

805 x 590 x 1320Dimension (mm) D x W x H

Overall Efficiency (Line mode)BATTERY

If the UPS is installed in a location where the altitude is above 1000m, the output power must be lowered by one percent for every 100m covered. L stands for Long-run modelS stands for Standard modelI stands for Isolation Transformer (Optional)*All specifications, designs and contents are subject to change without prior notice.

Page 41: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

39

Online UPS

The Most Versatile Solution For PowerProtectionThe Power Series is designed with the new state of art transformerless PWM technology that can be easily adapted to any kinds of complicated loads such as the non-linear systems (IT systems), highly inductive/capacitive loads, high-density discharge lamps and induction motors. The Power series is designed with 2 important criterions in mind; maximum efficiency and energy conservation. The unit also comes with a small form factor to allow for minimum installation effort. Furthermore, a parallel redundant system is integrated to allow two UPS models to operate in parallel as backup for each other. The Power Series is available incapacities ranging from 15 to 120kVA.

Online Double Conversion Technology with DSP ControlThe Power Series is able provide a higher load up-time and effective insulation against network disturbance with its online double conversion technology. A Digital Signal Processor (DSP) controller improves theperformance and efficiency of the UPS.

Advanced Control with Adaptive Feed Forward Cancellation (AFC) TechnologyBy cancelling both the input current and the output voltage harmonics, the harmful effects of harmonic injection can be eliminated and this enhances the load integrity.

Low Input Current Distortion (THDi < 1%)AFC cells are used to achieve extremely low distortion values. The Power series is able to obtain a low input current distortion at THDi < 1% under full load and a THDi < 5% under smaller load (i.e. 10% of load). This will prevent distortion of electrical network upstream and thus, result in the reduction of cable usage and protective devices in the electrical network.

Input Power Factor 0.99 At 10% LoadLower power losses would result in reducedconsumption, lower operation and maintenance costs.

Output Efficiency of up to 95%Designed with a DSP controller and fourth generation IGBT transistors, the UPS is able to achieve extremely high efficiency of up to 95%. With such high ratings, components in the UPS are not only protected but also prolonged due to the decrease in heat losses.

Small Form FactorUtilizes a transformerless technology allows the design of the UPS to be lighter and smaller.

Output Power FactorNowadays IT installation requirements are driving to power sources able to supply loads with leading power without affecting the power capability. Power E Series UPS are able to supply full power without any derating for all loads from 0.9 lagging to 0.9 leading. This unique characteristic avoids any UPS over sizing in case of unity or leading power factor as for the loads.

1,20

1,00

0,80

0,60

0,40

0,20

0,000% 25% 50%

LOAD

INPUT POWER FACTOR

PFin

100%

75%

50%

25%

0%0%

SERIES TIPICAL EFFICIENCY

25% 50%

EFFI

CIEN

CY

LOAD

Page 42: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

40

Online UPS

Front Access conceptAn important consideration has been given during the UPS design phase to create a system that allows users to access theunit’s electronic cards and powercomponents with minimum effort. All electronic boards and components can be accessed from the front panel for easy maintenance and replacement activities.

Versatile Single-Phase / Three-Phase set-upsThis highly versatile UPS is designed with different types of setting-up options;• Three-phase input / Three-phase output (III/III) • Three-phase input / Single phase output (III/I)

Control Components are designed to with stand all kinds of loadsIn the Power Series, the control components are designed to withstand all types of loads. These include loads such as; resistive, capacitive, non-linear,high-density discharge lamps, induction motors, speed drives etc. This makes the UPS extremely compatible with many types of electronics. Better yet, the UPS comes with a wide array of parameters that can be programmed locally or remotely to fit different types of environment.

N+1 RedundancyA parallel redundant system allows 4 UPS models to operate in parallel and as backup for each other.

Variety Of Communications And OptionAvailableThe UPS has provided the following standardcommunication selections:• Relay interface• RS-232/485 port• 1 × SNMP slot• Modbus RTU / SEC protocol• 2 × connectors for parallel connection

Made of 60% RecyclableMaterialsWhen it comes to conserving the environment, PROLiNK is committed to play a part by designing their UPS products using recyclable materials.

Back-up Time indicatorWith the use of simple algorithms, an estimatedremaining back-up time can be calculated andindications will be reflected on a LCD panel.

5.7” Multiple Languages Graphical LCDDisplayOur team of specialists has gathered together torevolutionize the UPS usability by adding in a 5.7” LCD monitor display with all information and alarmnotifications viewable within a single display.

Page 43: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

41

Online UPS

PPM Series

PROLiNK PowerModular (PPM)UPS System

• High efficiency online double conversion technology• High scalability• Unity output power factor• Modular design lowers MTTR• N+1 or N+X parallel redundancy for power guarantee• Ease of installation and maintenance• Flexible battery configuration adapts different applications• Adjustable charging current• High overload capability• Graphic 5.7” LCD design for easy management

PROLiNK PPM Series modular three-phase input / three-phase output online double conversion UPS takes scalability to a whole new level. Based on a scalable design, the PPM comes with a wide range of capacity, ranging from as low as 30kVA to as high as 210kVA. The PPM series is designed with a N+X parallel redundancy system that allows two or more UPS modules to operate in parallel and as back-up for each other. This unit provides an ideal protection for data centers, telecommunication facilities and other critical applications. Up to seven 30kVA modules can be fitted into a standard cabinet to simplify maintenance and replacement activities. The PPM Series guarantees a low mean-time-to-repair (MTTR), giving users a shorter elapsed time between the point of repair and the point of equipment recovery.

High Efficiency Online Double ConversionTechnologyPROLiNK PPM is designed with the latest online double conversion technology that provides a high efficiency rating of 96%. With such a high efficiency rating, the PPM can save you hundreds of dollars each year.

High ScalabilityBased on a scalable design, the PPM Series simplifies future expansion by making UPS units easily upgradable. This architecture allows you to meet power demands by adding additional modules vertically in a single rack enclosure.

Unity Output Power FactorWith a unity output factor (kVA = kW), the PROLiNKPPM UPS system is 100% compatible with today's high power factor loads. It is able to meet the latestserver requirements, giving the best value for your ITinvestments.

Modular Design Lowers MTTRThe modular design ensures uninterrupted power supply during UPS maintaining and replacing activities. Also, the PPM Series guarantees a low mean-time-to-repair (MTTR), giving users a shorter elapsed time between the point of repair and the point of equipment recovery.

DataCentre

Electro-MedicalDevice

StoragePLCS

EmergencyAlarm

Devices

E-Business(Server Farms,ISP/ASP/POP)

Local AreaNetwork

(LAN)

TelecommunicationDevices

Page 44: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

42

Online UPS

N+X Parallel RedundancyThe PPM series is designed with a N+X parallelredundancy system that allows two or more UPSmodules to operate in parallel and as back-up for each other.

Ease Of Installation and MaintenanceWith a built-in maintenance bypass feature, the UPS is able to deliver continuous power to the critical load during maintenance. Better yet, the PPS comes with a front access concept to facilitate installation.

Adjustable Charging CurrentPROLiNK PPM comes with a maximum charging current of up to 8A for each individual module. The charging current can be adjusted based on the necessaryrequirement.

High Overload CapabilityPROLiNK PPM supports 110% overload for 60 minutes,120% for 10 minutes and 150% for 1 minute.

5.7” LCD Graphic Mimic PanelA multilingual 5.7" graphic LCD screen is integrated as part of the design to provide users with visual information and advanced control abilities.

The PROLiNK PPM90 is a compact stand alone UPS system that provides the best backup solution for small and medium loads. This unit comes with a standard EIA height of 30U and is able to fit capacities ranging from 30kVA to 90kVA in the same cabinet. With features such as N+1 redundancy and the capability for future expansion, the PROLiNK PPM90 is definitely able to make your backup experience an absolute cinch.

PPM90

No. Of Module

1

2

3

Capacity

60kVA

90kVA

Dimension

600 x 1100 x 1485 (30U) mm

30kVA

Exterior Interior

The PROLiNK PPM210 is a standalone UPS system that comes with a standard EIA height of 42U. This unit is able to fit 7 x 30kVA modular redundancy in the same cabinet. Even better, the PPM210 has the capability to manage future capacity expansion of up to 210kVA, making the PPM210 the best backupsolution for greater loads.

PPM210

No. Of Module

1

2

3

4

5

6

7

Capacity

60kVA

90kVA

120kVA

150kVA

180kVA

210kVA

Dimension

600 x 1100 x 2030 (42U) mm

30kVA

Exterior Interior

Page 45: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

43

Online UPS

Full Specifications

When temperature above 30°C, the system output power factory will become 0.8One power module provides 30kW power capacity. One battery module contains 10 pcs of 12V7Ah, 12V9Ah or 12V10Ah (subject to requirement) Valve Regulated Lead Acid batteries.All specifications, designs and contents are subjected to changes without prior notice.

50/60Hz (auto-selectable)40Hz ~70Hz

> 0.99 @ 100% Load , >0.98 @ 50% Load< 3% @ 100% load

305 ~ 477 Vac @Full load, 208 ~ 477 Vac @ <70% load3 x 400 VAC (3Ph+N)Nominal Voltage

Voltage Range

UPS Power Modules

Nominal Frequency

Topology

Frequency RangePower FactorHarmonic Distortion (THDi)

PhaseTotal Capacity*

+/- 216V (12V x 36 pcs)Nominal VoltageMaximum VoltageMinimum VoltageFloat Charging Voltage

Maximum Charging Current

Medium Size (mm) D x W x HFull Size (mm) D x W x HENVIRONMENTOperation Temperature

AltitudeIP Class

<1000m for Nominal powerIP 20

INPUT

MODELS3-phase in/3-phase out

True Double-Conversion Online

PPM30 PPM60 PPM90 PPM120

30KW 60KW 90KW 120KW1 2 3 4

PPM150

150KW5

PPM180

180KW6

PPM210

210KW7

OUTPUT

BATTERY / CHARGER

Boost Charging Voltage

MANAGEMENT

PHYSICAL

Relative Humidity

50/60Hz46Hz ~ 54Hz or 56Hz ~ 64Hz

1 hour for 110%, 10 mins for 120%, ; 1 min for 150%, 200ms for >150%≦1.5% THD (Linear Load) ; ≦ 4% THD (Non-linear Load)

>94.5%

Voltage Regulation (Transient)Voltage Regulation (Steady state)

Nominal FrequencyFrequency Range (Synchronized)Overload CapabilityHarmonic DistortionEfficiency

≦± 5% Typical≦± 1% Typical (balanced load) ; ≦ ± 2% Typical (unbalanced load)

Temperature Compensation Yes8A (User-adjustable)

+/- 240V (12V x 40 pcs)+/- 192V (12V x 32 pcs)

2.25V / Cell2.35V / Cell

1100 x 600 x 1485 (30U) Not Applicable1100 x 600 x 2030 (42U)

0 ~ 95% non-condensing0 ~ 40°C

3 x 400 VAC (3Ph+N)Nominal Voltage

Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MACPower management from SNMP manager and web browser

IEC/EN 60950-1; IEC/EN 62040-1IEC/EN 62040-2 Category C3

Smart RS-232 / USBOptional SNMP

SafetyEMC

STANDARDS

Page 46: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

44

Online UPS

PRO-R Series

1U Online UPS 1000VA

DataCentre

Electro-MedicalDevice

StoragePLCS

EmergencyAlarm

Devices

E-Business(Server Farms,ISP/ASP/POP)

Local AreaNetwork

(LAN)

TelecommunicationDevices

PROLiNK PRO-R is a transformerless Online UPS that is designed with a small footprint. Despite being thinner andlighter, the PRO-R is able to provide similar performance as any other online UPS. Built with a true onlinedouble-conversion technology, it guarantees consistent and clean electrical power to fully protect your mission-critical devices.

In addition, the UPS comes with a built-in master and slave feature to conserve energy when the master device is no longer drawing current. PROLiNK PRO-R works with a variety of applications such as servers, networking and IP telephone systems.

• True double conversion online topology• Microprocessor control optimizes reliability• Output power factor 0.8• Input power factor correction• ECO mode for energy saving• Built-in serial communication port/Dry contact

Rear PanelFor PRO1000RS1. Ac Input2. Output Receptacles: Connect to Mission-critical Loads3. USB/ RS-232 Serial Communication Port4. ROO/ PRO Function Connector5. SNMP Intelligent Slot

For PRO1000RL1. Ac Input2. Output Receptacles: Connect to Mission-critical Loads3. USB/ RS-232 Serial Communication Port4. ROO/ PRO Function Connector5. SNMP Intelligent Slot6. Dry Contact7. External Battery Connector

134 5

2

IPS1000RS

IPS1000RL

5 2

4

617

Page 47: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

45

60/50 Hz (Auto sensing)

55-150 VAC or 110-300 VAC @ 50% load80-150 VAC or 160-300 VAC @ 100% load 110-300 VAC

110/120 VAC or 220/230/240 VAC 220/230/240 VACVoltage

Acceptable Voltage Range

Frequency Range

Capacity

Sealed Lead-acid battery Lithium-ion battery or Sealed Lead-acid batteryBattery Spec & Numbers (Battery voltage: 48VDC)

Battery TypeBattery Spec & Numbers

AC Mode to Batt. ModeInverter to Bypass

Typical Recharge Time

Sounding twice every secondSounding every second

Signal for AC Power Normal, Battery OK and Fault AlarmDry Contact (Option)

INPUT

MODELS PRO1000RS PRO1000RL1000 VA 1000 VA

OUTPUT

BATTERY

MANAGEMENT

ENVIRONMENT

PHYSICAL

INDICATORS

ALARM

EFFICIENCY

Sounding every 4 secondsBattery ModeLow Battery

LED

OverloadFault Continuously sounding

AC Mode

±1%

3:15:1 (110/120 VAC)3:1 (220/230/240 VAC)

Voltage Regulation

Frequency Range (Batt. Mode)Frequency Range

Current Crest Ratio

Harmonic Distortion

Transfer Time

≦ 3 % THD (Linear Load)≦ 5 % THD (Non-linear Load)

Waveform (Batt. Mode)

Battery Mode

50/60 ± 0.5% Hz40-70 Hz (50/60Hz Auto sensing)

Pure Sinewave4 ms (Typical)

0ms

6 V / 7 Ah x 4Back to 90% capacity in 4 hours Depending on external battery capacity

86%83%

AC mode, Battery mode, and fault indicators

110/120 VAC or 220/230/240 VAC 220/230/240 VACOutput Voltage

6300 x 440 x 44

20-90 % RH @ 0- 40°C (Non-condensing)Less than 50dBA @ 1 MeterNoise Level

Humidity

USB or RS-232

477 x 438 x 4413

Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MAC

Dimension (mm) D x W × HNet Weight (kgs)

Full Specifications

L stands for Long-run modelS stands for Standard modelI stands for Isolation Transformer (Optional)*All specifications, designs and contents are subject to change without prior notice.

Online UPS

Page 48: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

46

Online UPS

PRO-M Series

Online UPS1kVA - 6kVA

DataCentre

Electro-MedicalDevice

StoragePLCS

EmergencyAlarm

Devices

E-Business(Server Farms,ISP/ASP/POP)

Local AreaNetwork

(LAN)

TelecommunicationDevices

PRO-M Series is a true online double-conversion UPS system that provides clean and consistent electrical power to those who experience underserved power supply. It is designed with a wide input voltage range to handle voltage fluctuating situations to fail-safe your equipment.

The PRO-M Series is noticeably compact in size and is ideal for ATMs, banking and other business critical applications. Users can also adjust the charging current from 1A to 6A to suit their requirements.

• True double-conversion• Microprocessor control optimizes reliability• Output power factor 0.8• Wide input voltage (110 V – 300 V)• Converter mode available• ECO mode for energy saving (Only available for 1-3KVA)• Generator compatible• Smart SNMP works well with either USB or RS-232• Comprehensive display allows easy monitoring and access of UPS status

Rear PanelFor 1kVA to 2kVA model1. AC input2. Input circuit breaker3. USB communication port4. RS-232 communication port5. SNMP intelligent slot (optional)6. External battery connection (only available for EML model)7. Output receptacles8. Output circuit breaker9. Output terminal

PRO801M PRO801ML

PRO802M PRO802ML

53

2

7

1

4 53

2 7

6

1

4

5 3

2

7

1

4 53

271

4

Page 49: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

47

Online UPS

PRO803M PRO803ML

For 3kVA model1. AC input2. Input circuit breaker3. USB communication port4. RS-232 communication port5. SNMP intelligent slot (optional)6. External battery connection (only available for EML model)7. Output receptacles8. Output circuit breaker9. Output terminal

For 5kVA to 10kVA model1. External battery connector2. RS-232 communication port3. Intelligent slot4. USB communication5. Emergency power off function connector (EPO connector)6. Cooling fan7. Input circuit breaker8. Input/ Output terminal (Refer to diagram 3 for the details) 9. Maintenance bypass switch (option)10. Output terminal11. Grounding terminal12. Utility input terminal

53

2

7

91

453

2 7

9

1

4

PRO805M / PRO806M /PRO810M

PRO805ML /PRO806ML /PRO810ML

532

7

96

6

8

14

5

32

7

96

6

8

10 1211

14

Page 50: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

48

Full Specifications

L stands for Long-run modelS stands for Standard modelI stands for Isolation Transformer (Optional)*All specifications, designs and contents are subject to change without prior notice.

Online UPS

40 Hz ~ 70 Hz 46~54 Hz or 56~64 Hz

55-150 VAC or 110-300 VAC (Based on load at 50%)85-140VAC or 160-280VAC (Based on load at 100%)

110-300 VAC (Based on load at 50%)176-300 VAC (Based on load at 100%)

100/110/115/120/127VAC or 200/208/220/230/240VAC 208/220/230/240VACNominal Voltage

Phase

Input Voltage Range

Frequency RangePower Factor ≧ 0.99 @ Nominal Voltage (100% load)

Capacity 1000 VA 6000 VASingle phase with ground

12 V / 9 AhBattery TypeNumbersRecharge Time (Typical)Charging Current

Charging Voltage 27.4VDC ± 1% 54.7 VDC ±1% 82.1 VDC ±1% 115.2 VDC ±1% 218.4 VDC ±1% 273VDC±1%

Standard Model

Sounding twice every second

INPUT

MODELS PRO801M/ ML

2000 VA

PRO802M/ ML

3000 VA

PRO803M/ ML

5000 VA

PRO805M/ ML

10000 VA

PRO810M/ MLPRO806M/ ML

OUTPUT

BATTERY

MANAGEMENT

ENVIRONMENT

PHYSICAL

INDICATORS

Low Battery Sounding every second

EFFICIENCY

Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MACPower management from SNMP manager and web browser

Smart RS-232 / USB

Sounding every 4 secondsBattery Mode

LCD Display

OverloadFault Continuously sounding

AC Mode

±1%

3:1

Voltage Regulation

Frequency Range (Batt. Mode)Frequency Range (Synchronized Range)

Current Crest Ratio

Harmonic Distortion

Transfer Time AC to DCInverter to Bypass 4 ms (Typical) Zero

Zero

Waveform (Batt. Mode)

Battery Mode

1A 1 A / 2 A

50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz 50 Hz or 60Hz ± 0.1 Hz46~54 Hz or 56~64 Hz47~ 53 Hz or 57 ~ 63 Hz

Pure Sinewave

16 202 4 6 8Back to 90% capacity in 4 hours Back to 90% capacity in 9 hours

88%83% 85% 88% 90% 91%

90% 89% 92% 93%

≦ 3 % THD (Linear Load)≦ 6 % THD (Non-linear Load)

≦ 3 % THD (Linear Load)≦ 5 % THD (Non-linear Load)

Battery Type

Long-Run Model

Numbers

Charging Current 1A/2A/4A/6A (Adjustable) 1A/2A/4A/6A (Adjustable)1A/2A/4

(Adjustable)

Charging Voltage

Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicatorsALARM

2

27.4VDC± 1%

41.0VDC± 1%

54.7VDC±1%

82.1VDC±1%

109.4VDC±1%

82.1VDC±1%

109.4VDC±1%

273 VDC±1%115.2 VDC ±1% 218.4 VDC ±1%

3 4 6 8 6 8 2016Depending on the capacity of external batteries

100/110/115/120/127VAC or 200/208/220/230/240VAC 208/220/230/240VACOutput Voltage

282 x 145 x 220

442 x 190 x 688

442 x 190 x 318

20-90 % RH @ 0- 40°C (Non-condensing) 0-95% RH@0-40°C(Non-condensing)

0-95% RH@0-50°C(Non-condensing)

0-95% RH @ 0-40°C(Non-condensing)Humidity

Noise Level

Optional SNMP

Less than 50dBA @ 1 MeterLess than 58dBA

@ 1 MeterLess than 55dBA

@ 1 MeterLess than 58dBA

@ 1 Meter

282 x 145 x 2209.8 43

4.1397 x 145 x 220

397 x 145 x 22017

6.8

421 x 190 x 31827.6

7.4 15

369 x 190 x 688

369 x 190 x 31861

12

442 x 190 x 688

442 x 190 x 31866 75

16 18

Dimension (mm) D x W × HNet Weight (kgs)Dimension (mm) D × W × HNet Weight (kgs)

Standard Model

Long-Run Model

Page 51: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

49

Online UPS

PRO-EM Series

Online UPS1kVA - 10kVA

DataCentre

Electro-MedicalDevice

StoragePLCS

EmergencyAlarm

Devices

E-Business(Server Farms,ISP/ASP/POP)

Local AreaNetwork

(LAN)

TelecommunicationDevices

PRO-EM Series is a true online double-conversion UPS system that provides clean and consistent electrical power to those who experienceunderserved power supply. It is designed with a wide input voltage range to handle voltage fluctuating situations to fail-safe your equipment. Also, the UPS provides better output factor of up to 0.9 and is ideal for ATMs, banking and other business critical applications. PRO-EM Series comes with standard USB and RS-232 communication ports and a built-in intelligent slot for additional options such as adapters, protocol converters and relay contact cards.

• True double-conversion• Microprocessor control optimizes reliability• Input power factor correction• Output power factor 0.9• Wide input voltage• Converter mode available• ECO mode for energy saving only available for 1-3KVA models• Generator compatible• Smart SNMP works well with either USB or RS-232• Comprehensive display allows easy monitoring and access of UPS status

Rear PanelFor 1kVA model1. AC input2. Input circuit breaker3. USB communication port4. RS-232 communication port5. SNMP intelligent slot (optional)6. External battery connection (only available for EML model)7. Output receptacles

53

2

7

1

4

5

6

3

2 7

1

4

PRO801EM PRO801EML

Page 52: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

50

Online UPS

For 2kVA to 3kVA model1. AC input2. Input circuit breaker3. USB communication port4. RS-232 communication port5. SNMP intelligent slot (optional)6. External battery connection (only available for EML model)7. Output receptacles8. Output circuit breaker9. Output terminal

For 6kVA to 10kVA model1. External battery connector2. RS-232 communication port3. Intelligent slot4. USB communication5. Emergency power off function connector (EPO connector)6. Cooling fan7. Input circuit breaker8. Input/ Output terminal9. Maintenance bypass switch (optional)10. Output terminal11. Grounding terminal12. Utility input terminal

45

2

7

1

3 5

6

3

27

1

4

PRO802EM

PRO803EM PRO803EML

PRO802EML

45

2

7

1

9

35

6

3

2

9

7

1

4

PRO810EMLPRO810EM

41 5

3

6

6 7

9

8

2

41 5

3

6

6 7

9

8

1011

12

2

Page 53: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

51

L stands for Long-run modelS stands for Standard modelI stands for Isolation Transformer (Optional)*All specifications, designs and contents are subject to change without prior notice.

Online UPS

Full Specifications

40 Hz ~ 70 Hz 46~54 Hz or 56~64 Hz

60-150 VAC or 120-300 VAC at 50% load90-140 VAC or 180-280 VAC at 100% load

110-300 VAC (Based on load at 50%)176-300 VAC (Based on load at 100%)

100/110/115/120/127VAC or 200/208/220/230/240VAC 208/220/230/240VACNominal Voltage

Phase

Input Voltage Range

Frequency RangePower Factor ≧ 0.99 @ Nominal Voltage (100% load)

Capacity 1000 VA 10000 VASingle phase with ground

12 V / 9 AhBattery TypeNumbersRecharge Time (Typical)Charging CurrentCharging Voltage 27.4VDC ± 1% 54.7 VDC ±1% 82.1 VDC ±1% 218.4 VDC ±1% 273 VDC ±1%

Standard Model

Sounding twice every second

INPUT

MODELS PRO801EM/ EML

2000 VA

PRO802EM/ EML

3000 VA

PRO803EM/ EML

6000 VA

PRO806EM/ EML PRO810EM/ EML

OUTPUT

BATTERY

MANAGEMENT

ENVIRONMENT

PHYSICAL

INDICATORS

Low Battery Sounding every second

EFFICIENCY

Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MACPower management from SNMP manager and web browser

Smart RS-232 / USB

Sounding every 4 secondsBattery Mode

LCD Display

OverloadFault Continuously sounding

AC Mode

±1%

3:1

Voltage Regulation

Frequency Range (Batt. Mode)Frequency Range (Synchronized Range)

Current Crest Ratio

Harmonic Distortion

Transfer Time AC to DCInverter to Bypass 4 ms (Typical) Zero

Zero

Waveform (Batt. Mode)

Battery Mode

1.0A 1A, 2A (Adjustable)

50 Hz or 60Hz ± 0.5% 50 Hz or 60Hz ± 0.1 Hz46~54 Hz or 56~64 Hz47~ 53 Hz or 57 ~ 63 Hz

Pure Sinewave

16 202 4 6Back to 90% capacity in 4 hours Back to 90% capacity in 9 hours

88%83% 85% 88% 90%

89% 90% 94%91%

≦ 3 % THD (Linear Load)≦ 6 % THD (Non-linear Load)

≦ 3 % THD (Linear Load)≦ 5 % THD (Non-linear Load)

Battery Type

Long-Run Model

NumbersCharging Current 1A/2A/4A/6A 1A, 2A, 4A (Adjustable)Battery Type

Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicatorsALARM

2

27.4VDC ± 1% 54.7 VDC ±1% 82.1 VDC ±1% 218.4 VDC ±1% 273 VDC ±1%

4 6 16 20Depending on the capacity of external batteries

100/110/115/120/127VAC or 200/208/220/230/240VAC 208/220/230/240VACOutput Voltage

282 x 145 x 220

421 x 190 x 318

397 x 145 x 220

20-90 % RH @ 0- 40°C (Non-condensing) 0-95% RH@0-50°C(Non-condensing)

0-95% RH @ 0-40°C(Non-condensing)Humidity

Noise Level

Optional SNMP

Less than 50dBA @ 1 Meter Less than 55dBA@ 1 Meter

Less than 58dBA@ 1 Meter

282 x 145 x 2209.8 27.6

4.1397 x 145 x 220

397 x 145 x 22017

6.8 7.4

369 x 190 x 688

369 x 190 x 31861

12

442 x 190 x 688

442 x 190 x 31876

16

Dimension (mm) D x W × HNet Weight (kgs)Dimension (mm) D × W × HNet Weight (kgs)

Standard Model

Long-Run Model

Page 54: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

52PRO633030S / PRO633040S PRO633060S / PRO633080S

Online UPS

Giant Series

Online UPS30kVA - 80kVA

DataCentre

Electro-MedicalDevice

StoragePLCS

EmergencyAlarm

Devices

E-Business(Server Farms,ISP/ASP/POP)

Local AreaNetwork

(LAN)

TelecommunicationDevices

PROLiNK Giant Series (3P/3P) three-phase input/ three-phase output, true online double conversion UPS system guarantees to supplyconsistent and quality electrical power to protect your mission critical applications. The front access design makes it easy for users to perform maintenance and replacement activities.

A parallel redundant system is implemented in the Giant Series to provide adequate power supply in the event where a single module fails or needed to be taken offline for service. The Giant Series (3P/3P) also comes with a built-in transformer to provide 100% protection against unexpected AC power problems.

• True double-conversion• Microprocessor control optimizes reliability• Input power factor correction• Output power factor 0.9• Wide input voltage• Converter mode available• Generator compatible• Smart SNMP works well with either USB or RS-232• Comprehensive display allows easy monitoring and access of UPS status

Rear PanelFor 30kVA to 80kVA model1. Intelligent slot2. Output circuit breaker3. Input circuit breaker4. Emergency power off function connector (EPO connector)5. USB communication6. RS-232 communication port7. RS-485 communication port8. Parallel connection9. AC input10. Bypass11. Maintenance bypass12. AC output13. Battery

532

7

9 10 11 12 13

6

8

1

4

532

7

9 10 11 12 13

6

8

1

4

Page 55: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

53

Full Specifications

L stands for Long-run modelS stands for Standard modelI stands for Isolation Transformer (Optional)*All specifications, designs and contents are subject to change without prior notice.

Online UPS

50/60 Hz ± 10 %304VAC ~ 440VAC

3 x 380VAC/400VAC (3Ph + N)Nominal VoltageAcceptable Voltage RangeFrequency

Capacity 30 kVA 80 kVA

STATIC BYPASSTypeVoltageFrequencyActivation Criterion Microprocessor control

INPUT

MODELS PRO633030S40 kVA

PRO633040S60 kVA

PRO633060S PRO633080S

INVERTER

Current Limit

PHYSICAL

Nominal Battery Voltage

MAINTENANCE BYPASS

95%

Admissible Crest Factor 3:1

847.5 x 432.4 x 1134.5 1054 x 508 x 1287532462298271.5

Dimensions, D x W x H(mm)

90%50/60 Hz

Overall EfficiencyLow BatteryOverall Efficiency

Type

BATTERY & CHARGERBattery Type and Numbers 12V x 30 pcs, sealed lead acid battery

360 VDC

Admissible Power Factor

Stationary: ±1%Transitory: ±5% (load variations 100-0-100%)

Pure Sinewave

Precision

Max. Synchronisation Speed

Frequency

WaveformTotal Harmonic Distortion (THDv)Phase DisplacementDynamic Recovery Time 1 cycle at 98 % of the static value

120º ±1% (balanced load) ; 120º ±2% (imbalances 50% of the load)

Admissible Overload

Imbalance Output Voltage @ 100% Unbalanced Load

50/60 Hz

±1 Hz/s

50/60 Hz synchronised ±1 %With mains absent ±0.1 Hz

110% for 60min,125% for 10 min, 150% for 60s

Solid state3 x 380VAC/400VAC (3Ph + N)

<1%

High overload, short-circuit: RMS Voltage LimitHigh Crest-Factor current: Peak Voltage Limit

0.6~1 (inductive or capacitive)

<2% (Linear Load) ; <5% (Non-linear Load)

Transfer TimeAdmissible OverloadTransfer to Bypass Immediate, for overloads above 150%Retransfer

Without interruption3 x 400V (3Ph + N)Voltage

Frequency

Automatic after alarm clear

200% for 10 secZero

3 x 380VAC/400VAC (3Ph + N)Nominal Voltage

CC/CV

40 A

Net Weight (Kgs)

±1%

405 VDC

Charging MethodPrecisionCharging CurrentCharging Voltage

Page 56: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

54

Online UPS

Key Features

Jupiter Series (3P/3P)

Online Jupiter Series10kVA - 320kVA

• True Galvanic Isolation technology designed to provide full protection against high voltage surges, noise and leakage current etc• Plug and Play modular design allows users to carry out maintenance and repair works effortlessly• Cold start function• Multi-CPU design• Hot-swappable battery design• Temperature compensation for battery charging• Wide input voltage range• Output power factor of 0.80• Software and Hardware redundant design• EMI suppression provides approximately 200dB noise reduction • Static Bypass Switch provides automatic transfer to a back-up power source in the event of a failure within the UPS• Maintenance Bypass Switch• Smart battery charger designed to optimize battery performance• LCD User Interface

• Remote control panel • PC monitoring software• Auto dialling module • SNMP/ HTTP network card • Emergency Power Off switch (EPO)

Options

Page 57: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

55

Online UPS

Full Specifications

50 / 60Hz +/- 7%307 – 520V

380 / 400 / 415VAC 3 Phase 4 WireInput VoltageInput RangeInput FrequencyInput Power FactorNormal Input Current(A)

0.818 36 54 72 90 10824 45 68 90 113 136

Capacity 10kVA 40kVA 50kVA 60kVA

Seal Lead Acid / NiCdTypeNo. Of CellsVoltage RangeMaximum Charge Current (Adc)

0.8+ / - 1 %

0 ms30 sec1 secYes

91% 92%91.5%

Mains > InverterInverter > Mains

Overload100%300%

En50091-1,-2Fcc Class AShort Circuit

Isolation With Output

HumidityAltitudeMaximum Heat Dissipation(Kw)Weight(Kg) (No Battery)Dimension (mm) D x W x HAudible Noise

Standards

ProtectionsLightningEmc FilterGalvanic Isolation

Data Display By LcdLED,LCD,BUZZER

Indications & Alarms Dry ContactBattery Start

OVERALL CHARACTERISTICSOverall Efficiency

INPUT

MODELS PRO533010S PRO533040S PRO533050S PRO533060S30kVA20kVA

PRO533030SPRO533020S

BATTERY

OPERATING ENVIRONMENT

STATIC SWITCH

Voltage Regulation 100% Unbalance Load

INVERTER

0 – 40°F ( 32 – 104°F )0% - 90% ( Non–condensing )

<1500m Above Sea Level

800 x 550 x 1600< 65 dBA (@ 1 m)

YesYes

Rectifier, Reserve, Bypass NfbMov

Input & OutputBetween Input & Output

YesYesYes

Yes

0.65 1.3 1.9 2.6 3 3.5270 300 400 480 550 680

Temperature

Sinusoid

Output Power Factor

Dc Input RangeWave FormOutput Voltage 380 / 400 / 415 VAC 3 Phase 4 Wire

0% - 100% : 20 sec

5427 81 108 135 162

Power Walk In

Voltage RegulationEfficiency

Current Limit(A)Ripple Voltage

5 10 15 20 25 30

1%99%

174 / 271295 – 410VDC / 285-415VDC

0.5%

Battery Low VoltageBattery Low Stop Boost ChargeFloat Charge

285 – 420VDC

320VDC / 305VDC295VDC / 285VDC402VDC / 415VDC390VDC / 410VDC

Maximum Input Current(A)

45 – 55Hz / 55 – 65Hz

45 – 55Hz / 55 – 65Hz99.5%

Frequency Range173 – 277 VAC (Line To Neutral)Voltage Range

Efficiency0 ms

Transfer Time

50 / 60Hz + / - 0.1Hz

< 2 %Continuous

15 min10 min60 sec

93% 94%93.5%43 87 130 174 218 260

Frequency Lock RangeOutput Frequency (Free Running)Phase Shift Under 100% Unbalance LoadTHD (Linear Load)

Efficiency (100% Load)Maximum Output Peak Current(A)

Overload

<110%110 - 125%125 - 150%>150%

120 % + / - 0.5°

10KVA ~ 60KVA UPS 3-Phase Input / 3-Phase Output

Page 58: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

56

Online UPS

50 / 60Hz +/- 7%307 – 520V

380 / 400 / 415VAC 3 Phase 4 WireInput VoltageInput RangeInput FrequencyInput Power FactorNormal Input Current(A)

0.8144 180 216 288180 225 270 360

Capacity 80kVA 160kVA

Seal Lead Acid / NiCdTypeNo. Of CellsVoltage RangeMaximum Charge Current (Adc)

0.8+ / - 1 %

0 ms30 sec1 secYes

92.5% 93%

Mains > InverterInverter > Mains

Overload100%300%

En50091-1,-2Fcc Class AShort Circuit

Isolation With Output

HumidityAltitudeMaximum Heat Dissipation(Kw)Weight(Kg) (No Battery)Dimension (mm) D x W x HAudible Noise

Standards

ProtectionsLightningEmc FilterGalvanic Isolation

Data Display By LcdLED,LCD,BUZZER

Indications & Alarms Dry ContactBattery Start

OVERALL CHARACTERISTICSOverall Efficiency

INPUT

MODELS PRO533080S PRO533160S120kVA100kVA

PRO533120SPRO533100S

BATTERY

OPERATING ENVIRONMENT

STATIC SWITCH

Voltage Regulation 100% Unbalance Load

INVERTER

0 – 40°F ( 32 – 104°F )0% - 90% ( Non–condensing )

<1500m Above Sea Level

800 x 1100 x 1600< 65 dBA (@ 1 m)

YesYes

Rectifier, Reserve, Bypass NfbMov

Input & OutputBetween Input & Output

YesYesYes

Yes

4.6 5.4 6.5 8.7820 950 1180 1450

Temperature

Sinusoid

Output Power Factor

Dc Input RangeWave FormOutput Voltage 380 / 400 / 415 VAC 3 Phase 4 Wire

0% - 100% : 20 sec

270216 324 432

Power Walk In

Voltage RegulationEfficiency

Current Limit(A)Ripple Voltage

40 50 60 80

1%99%

174 / 271295 – 410VDC / 285-415VDC

0.5%

Battery Low VoltageBattery Low Stop Boost ChargeFloat Charge

285 – 420VDC

320VDC / 305VDC295VDC / 285VDC402VDC / 415VDC390VDC / 410VDC

Maximum Input Current(A)

45 – 55Hz / 55 – 65Hz

45 – 55Hz / 55 – 65Hz99.5%

Frequency Range173 – 277 VAC (Line To Neutral)Voltage Range

Efficiency0 ms

Transfer Time

50 / 60Hz + / - 0.1Hz

< 2 %Continuous

15 min10 min60 sec

94.5% 95%348 432 520 693

Frequency Lock RangeOutput Frequency (Free Running)Phase Shift Under 100% Unbalance LoadTHD (Linear Load)

Efficiency (100% Load)Maximum Output Peak Current(A)

Overload

<110%110 - 125%125 - 150%>150%

120 % + / - 0.5°

80KVA ~ 160KVA UPS 3-Phase Input / 3-Phase Output

Page 59: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

57

Online UPS

50 / 60Hz +/- 7%307 – 520V

380 / 400 / 415VAC 3 Phase 4 WireInput VoltageInput RangeInput FrequencyInput Power FactorNormal Input Current(A)

0.8350 420 525 560437 525 656 700

Capacity 200kVA 320kVA

Seal Lead Acid / NiCdTypeNo. Of CellsVoltage RangeMaximum Charge Current (Adc)

0.8+ / - 1 %

0 ms30 sec1 secYes

93%

Mains > InverterInverter > Mains

Overload100%300%

En50091-1,-2Fcc Class AShort Circuit

Isolation With Output

HumidityAltitudeMaximum Heat Dissipation(Kw)Weight(Kg) (No Battery)Dimension (mm) D x W x HAudible Noise

Standards

ProtectionsLightningEmc FilterGalvanic Isolation

Data Display By LcdLED,LCD,BUZZER

Indications & Alarms Dry ContactBattery Start

OVERALL CHARACTERISTICSOverall Efficiency

INPUT

MODELS PRO533200S PRO533320S300kVA240kVA

PRO533300SPRO533240S

BATTERY

OPERATING ENVIRONMENT

STATIC SWITCH

Voltage Regulation 100% Unbalance Load

INVERTER

0 – 40°F ( 32 – 104°F )0% - 90% ( Non–condensing )

<1500m Above Sea Level

800 x 2200 x 1600< 65 dBA (@ 1 m)

YesYes

Rectifier, Reserve, Bypass NfbMov

Input & OutputBetween Input & Output

YesYesYes

Yes

11.5 13 16.3 17.42500 2700 3000 3100

Temperature

Sinusoid

Output Power Factor

Dc Input RangeWave FormOutput Voltage 380 / 400 / 415 VAC 3 Phase 4 Wire

0% - 100% : 20 sec

630525 788 840

Power Walk In

Voltage RegulationEfficiency

Current Limit(A)Ripple Voltage

100 120 150 160

1%99%

174 / 271295 – 410VDC / 285-415VDC

0.5%

Battery Low VoltageBattery Low Stop Boost ChargeFloat Charge

285 – 420VDC

320VDC / 305VDC295VDC / 285VDC402VDC / 415VDC390VDC / 410VDC

Maximum Input Current(A)

45 – 55Hz / 55 – 65Hz

45 – 55Hz / 55 – 65Hz99.5%

Frequency Range173 – 277 VAC (Line To Neutral)Voltage Range

Efficiency0 ms

Transfer Time

50 / 60Hz + / - 0.1Hz

< 5 %Continuous

15 min10 min60 sec

95%800 1000 1250 1300

Frequency Lock RangeOutput Frequency (Free Running)Phase Shift Under 100% Unbalance LoadTHD (Linear Load)

Efficiency (100% Load)Maximum Output Peak Current(A)

Overload

<110%110 - 125%125 - 150%>150%

120 % + / - 0.5°

200KVA ~ 320KVA UPS 3-Phase Input / 3-Phase Output

*All specifications, designs and contents are subject to change without prior notice.

Page 60: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

58

Line Interactive UPS

PRO SFC Series

Super Fast Charging Line Interactive Series650VA - 1200VA

• Built-in super fast charger, battery can be recharged to 90% of its capacity within 2-4 hours• Excellent microprocessor control guarantees high reliability• Boost and buck AVR for voltage stabilization• Auto restart while AC is recovering• Simulated sine wave• Off-mode charging• Cold start function• Optional USB/RS-232 communication port and RJ-11/RJ-45 protection

PROLiNK SFC series is a single-phase input/ single-phase output Line-Interactive UPS system with PROLiNK’s latest Super-Fast Charging technology. This cutting-edge technology is able to recharge the battery back to 90% of its capacity within 2-4 hours, and is ideal for providing stable backup power to home/ small office applications. A wide input voltage range is supported due to the integrated 3-Step AVR which features 2 boosts and 1 buck to regulate output voltage. This prevents under voltage brownouts and over voltage surges. The unit also comes with universalsockets to provide better compatibility with a wider range of devices.

Rear PanelFor 650VA to 1200VA model1. AC Input2. Backup Output3. Bypass Output (without battery back up)4. USB Port (Only available in SFCU series)5. RJ11

PC Printer Work-Stations

PRO1200SFC/ SFCU

5

12

2 3

4

PRO700SFC/ SFCU PRO850SFCU

12

2

4

5

1

2

2

4

Page 61: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

59

Line Interactive UPS

Full Specifications

*All specifications, designs and contents are subject to change without prior notice.

50 or 60Hz (Auto Sensing)140-300VAC

220/ 230/ 240VACNominal VoltageVoltage RangeNominal Frequency

Capacity 650VA 1200

1 x 12V8.2AH 1 x 12V10AH 2 x 12V8.2AHNumber of BatteryRecharge Time (Typical)

Battery Mode – Sounding every 10 secondsLow Battery – Sounding every second

Overload – Sounding every 0.5 secondsBattery Replacement Alarm – Sounding every 2 seconds

Fault – Continuously Sounding

INPUT

MODELS PRO700SFC/ SFCU850

PRO850SFCU PRO1200SFC/ SFCU

OUTPUT

BATTERY

PROTECTION

MANAGEMENT

ENVIRONMENT

PHYSICAL

INDICATION

ALARM

Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MACUSB/ RS-232

LED Display

Sounding

Simulated SinewaveTransfer Time (Typical)Frequency

WaveformTypical 2-6 ms 2 - 6ms, 10ms (max)

50Hz or 60Hz ±1Hz

Full Protection Short Circuit, Overload, Discharge and Overcharge Protection

Back to 90% capacity in 2-4 hours

AC Mode – Green LightingBattery Mode – Yellow Lighting

Charging Mode – Green Flashing every 2 secondsOverload – Red Flashing every 0.5 seconds

Fault – Red Lighting

±10%Output Voltage Regulation (Battery Mode)

350 x 146 x 160287 x 100 x 142

Less than 40dBNoise Level0-90% relative Humidity, 0°C - +40°CHumidity

84.25 4.9Dimension (mm) D x W × HNet Weight (kgs)

Page 62: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

60

Line Interactive UPS

• Built-in super fast charger, battery can be recharged to 90% of its capacity within 2-4 hours• Excellent microprocessor control guarantees high reliability• Boost and buck AVR for voltage stabilization• Auto restart while AC is recovering• Simulated sine wave• Off-mode charging• Cold start function• LCD User Interface

The PRO SFT series is a single-phase input/ single-phase output Line-Interactive UPS system with PROLiNK's latest Super-Fast Charging technology. It allows for the battery to be recharged back to 90% of its capacity within 2-4 hours, and is ideal for providing stable backup power to home/ small office applications.

A wide input voltage range is supported due to the integrated 3-Step AVR which features 2 boosts and 1 buck to regulate output voltage. This helps prevent under voltage brownouts and over voltage surges. The unit also comes with a LCD user interface that provides valuable information such as output voltage, input voltage, load level, battery voltage and overload warning signals.

Rear PanelFor 650VA to 1200VA model1. AC Input2. Backup Output3. Bypass Output (without battery back up)4. USB Port (Only available in SFTU series)5. RJ11

PC Printer Work-Stations

PRO1200SFT/ SFTU

5

12

2 3

4

PRO700SFT/ SFTU PRO850SFTU

12

2

4

5

1

2

2

4

PRO SFT Series

Super Fast Charging Line Interactive WithTouch Screen Panel650VA - 1200VA

Page 63: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

61

Line Interactive UPS

*All specifications, designs and contents are subject to change without prior notice.

Full Specifications

50 or 60Hz (Auto Sensing)140-300VAC

230VACNominal VoltageVoltage RangeNominal Frequency

Capacity 650VA 1200

1 x 12V8.2AH 1 x 12V10AH 2 x 12V8.2AHNumber of BatteryRecharge Time (Typical)

Battery Mode – Sounding every 10 secondsLow Battery – Sounding every second

Overload – Sounding every 0.5 secondsBattery Replacement Alarm – Sounding every 2 seconds

Fault – Continuously Sounding

INPUT

MODELS PRO700SFT/ SFTU850

PRO850SFTU PRO1200SFT/ SFTU

OUTPUT

BATTERY

PROTECTION

MANAGEMENT

ENVIRONMENT

PHYSICAL

Display

ALARM

Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MACUSB/ RS-232

LCD Display

Sounding

Simulated SinewaveTransfer Time (Typical)Frequency

WaveformTypical 2-6 ms 2 - 6ms, 10ms (max)

50Hz or 60Hz +/ -1 Hz

Full Protection Short Circuit, Overload, Discharge and Overcharge Protection

Back to 90% capacity in 2-4 hours

Input voltage, output voltage, battery level, load level and UPS status

+/ -10%Output Voltage Regulation (Battery Mode)

350 x 146 x 160300 x 101 x 142

Less than 40dBNoise Level0-90% relative Humidity, 0°C - 40°C (Non -condensing)Humidity

84.4 5Dimension (mm) D x W × HNet Weight (kgs)

Page 64: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

62

Line Interactive UPS

PRO Series

Line Interactive Series 650VA – 1200VA

• Built-in super smart charger, shorten 50% of charging time• Excellent microprocessor control guarantees high reliability• Boost and buck AVR for voltage stabilization• Auto restart while AC is recovering• Simulated sine wave• Off-mode charging• Cold start function• Optional USB/RS-232 communication port and RJ-11/RJ-45 protection• Offering LED and LCD panels for selections

PRO Series is a single-phase input / single-phase output line-interactive UPS system. It is able to provide clean electrical power and is ideal for home / small officeapplications. A wide input voltage range is supported due to the integrated 3-Step AVR which features 2 boosts and 1 buck to regulate output voltage. This prevents under voltage brownouts and over voltage surges. The unit also comes with universal sockets to provide better compatibility with a wider range of devices.

Rear PanelFor 650VA to 1200VA model1. AC Input2. Backup Output3. Bypass Output (without battery back up)4. USB Port (Only available in VU and SVU series)5. RJ11

PC Printer Work-Stations

PRO700V/ VU PRO850VU PRO850SU PRO1200SV/ SVU

12

2

45

12

2 3

4

1

2

2

3

5

1

2

2

4

Page 65: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

63

Line Interactive UPS

Full Specifications

50 or 60Hz (Auto Sensing)140-300VAC

220/ 230/ 240VACNominal VoltageVoltage RangeNominal Frequency

Capacity 650VA 1200

1 x 12V8.2AH 1 x 12V10AH 2 x 12V8.2AHNumber of BatteryRecharge Time (Typical)

Battery Mode – Sounding every 10 secondsLow Battery – Sounding every second

Overload – Sounding every 0.5 secondsBattery Replacement Alarm – Sounding every 2 seconds

Fault – Continuously Sounding

INPUT

MODELS PRO700V/ VU850

PRO850VU/ SU PRO1200SV/ SVU

OUTPUT

BATTERY

PROTECTION

MANAGEMENT

ENVIRONMENT

PHYSICAL

INDICATION

ALARM

Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MACUSB/ RS-232

LED Display

Sounding

Simulated SinewaveTransfer Time (Typical)Frequency

WaveformTypical 2-6 ms 2 - 6ms, 10ms (max)

50Hz or 60Hz ±1Hz

Full Protection Overload, discharge, and overcharge protection

Back to 90% capacity in 4-6 hours

AC Mode – Green LightingBattery Mode – Yellow Lighting

Charging Mode – Green Flashing every 2 secondsOverload – Red Flashing every 0.5 seconds

Fault – Red Lighting

±10%Output Voltage Regulation (Battery Mode)

350 x 146 x 160287 x 100 x 142

Less than 40dBNoise Level0-90% relative Humidity, 0°C - +40°CHumidity

84.25 4.9Dimension (mm) D x W × HNet Weight (kgs)

*All specifications, designs and contents are subject to change without prior notice.

Page 66: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

64

PRO-L Series

Line Interactive Series 600VA – 2000VA

• Excellent microprocessor control guarantees high reliability• Boost and buck AVR for voltage stabilization• Adjustable battery charging current• Auto restart while AC is recovering• Off-mode charging• Cold start function• Simulated sine wave

PRO-L Series is a single-phase input / single-phase output line-interactive UPS system that provides clean and reliable back-up power for longer periods of time. It is able to provide clean electrical power and is ideal for home / small office applications. A wide input voltage range is supported due to the integrated 3-Step AVR which features 2 boosts and 1 buck to regulate output voltage. High voltage batterychargers and battery extension assembly are madeavailable for longer runtime applications. The PRO-L Series with capacities of up to 850VA also comes with universal sockets to provide better compatibility with a wider range of devices.

Rear PanelFor 600VA to 2000VA model1. AC input2. Input protection3. Output outlet4. Battery Connection5. Fan

PC Printer Work-Stations

Line Interactive UPS

PRO1000L/PRO2000L

PRO700L

512

3

4

5

1

2

33

4

Page 67: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

65

Line Interactive UPS

Battery PackFor 600VA to 2000VA model

Model

Battery Type

Battery Number

Dimension (DxWxH) mm

G6

6 pcs

397 × 145 × 220

12 pcs

G12 G18 G60

18 pcs 60 pcs

421 × 190 × 318 535 × 190 × 318

12V7AH/ 12V9AH/ 12V10AH

830 x 250 x 576

Full Specifications

50Hz140 - 300VAC

220/ 230/ 240VACNominal VoltageVoltage RangeNominal Frequency

Capacity 600VA 2000

12VDC 24VDCBattery VoltageBattery CapacityCharging Current (max.)

Low Battery – Sounding every secondOverload – Sounding every 0.5 seconds

Battery Replacement Alarm – Sounding every 2 secondsFault – Continuously Sounding

INPUT

MODELS PRO700L1000

PRO1000L PRO2000L

OUTPUT

BATTERY

Dimension (mm) D x W × H

PROTECTION

ENVIRONMENT

PHYSICAL

INDICATION

ALARM

LED Display

Sounding

Simulated SinewaveTransfer Time (Typical)Frequency

Waveform

50 Hz ±1 HzTypical 4-8 ms

Full Protection Overload, discharge, and overcharge protection

Depending on the application

AC Mode – Green LightingBattery Mode – Yellow Lighting

Fault – Red Lighting

±10%Output Voltage Regulation (Battery Mode)

395 x 145 x 220358.5 x 96.8 x 146.5

5A/ 10A/ 15A/ 20A (adjustable)2.5A/ 6A/ 10A (adjustable)

Less than 40dBNoise Level0-90% relative Humidity, 0°C - +40°CHumidity

13.555.8 9.0Net Weight (kgs)

*All specifications, designs and contents are subject to change without prior notice.

Page 68: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

66

PRO Rack/ Tower Series

Line Interactive Series 800VA – 3000VA

• Microprocessor-based line interactive design• Pure sine wave output online mode and battery mode• User-friendly and easy-shift LCD display• Rack/Tower design• Built-in boost and buck AVR• Output Power Factor 0.8• Hot swappable battery design• Programmable power management outlets• Emergency Power Off Function (EPO)• Long-run models available• Multiple communication available• Option for SNMP communication.

PRO Rack / Tower series is a single-phase input / single-phase output UPS that employs a line-interactive technology. This device comes with a practical 2U universal-mount case that provides an option for the user to either install it as a floor-standing tower or in a mounting position using a 19-inch rack mount bracket. With its high density output power factor of 0.8, this device is able to provide outstanding performance and efficiency for any home / small officeapplications. A wide input voltage range is supported due to the integrated 3-Step AVR which features 2 boosts and 1 buck to regulate output voltage.

Rear PanelFor 800VA to 3000VA model1. Programmable outlets: Connect to non-critical loads2. Output receptacles: Connect to mission-critical loads3. AC input4. Input circuit breaker5. Network/Fax/Modem surge protection6. Emergency power off function connector (EPO)7. USB communication port8. RS-232 communication port9. SNMP intelligent slot10. Battery Compartment (only available for Standard model)11. Output terminal (IEC320-14)12. Fan13. External battery pack numbers detection port

Line Interactive UPS

PC Printer Work-Stations 19” RackMount

PRT800S

PRT1100S/ PRT1100L/ PRT2000S/ PRT2000L

PRT3000S/ PRT3000L

5 16

7

89 12

13 2

34

5 16

7

89 12

1013 2

34

5 167

891212

10

13 2

113

4

Page 69: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

67

Line Interactive UPS

Battery PackFor 1.1kVA to 3kVA model

Model

Battery Type

Battery Number

Dimension (DxWxH) mm

G8R G12R G20R

480 x 438 x 88

8 pcs 12 pcs 20 pcs

12V7AH/ 12V9AH/ 12V10AH

580 x 438 x 133600 x 438 x 88

Full Specifications

50 or 60Hz162 ~ 290VAC

208/ 220/ 230/ 240VACNominal VoltageVoltage RangeNominal Frequency

Capacity 800 VA 3000 VA

≦ 15% THD≦ 8% THD

Waveform

4A / 8AN/ADepending on the applicationDepending on the application

Charging CurrentCapacityType

AC Mode, Battery Mode, Load Level, Battery Level, Input Voltage, Output Voltage, Overload, Fault, and Low Battery

380 x 438 x 88

INPUT

MODELS PRT800S1100 VA

PRT1100S/ L PRT3000S/ L2000 VA

PRT2000S/ L

OUTPUT

Voltage DistortionLiner LoadNon-Liner Load

EFFICIENCY

MANAGEMENT

ENVIRONMENT

PHYSICAL

INDICATORS

BATTERY

Long-Run Model

Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MACUSB/ RS-232

Standard Model

LCD Display

3:1Power FactorFrequency

Current Crest Ratio0.8

50Hz or 60Hz ±1Hz

AC Mode Up to 97%

Pure Sinewave

Value regulated Lead Acid battery (Maintenance free batteries)

Back to 90% capacity in 4 hours1.0 A (max.)

TypeCapacityRecharge Time (Typical)Charging Current

±3%Voltage Regulation (Batt. Mode)

600 x 438 x 88380 x 438 x 88

≤ 45dB @ 1 Meter0°C - +40°C

Noise LevelAmbient Temperature

0-90% (Non-condensing)Operation Humidity

18480 x 438 x 88

14N/A

10.8Long-Run Model

Dimension (mm) D x W × H

Standard ModelDimension (mm) D × W × H

Net Weight (kgs)

Net Weight (kgs) 12.9 14.23480 x 438 x 88

23.1600 x 438 x 88

32.24

7AH 9AH

*All specifications, designs and contents are subject to change without prior notice.

Page 70: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

68

Outdoor Line Interactive UPS

Outdoor Line Interactive Series

• Selectable transfer time for normal or generator mode• User-adjustable charging current• Adjustable input threshold voltage• Provides programmable signals for dry contacts• Battery compensation design• RS-232, USB and SNMP intelligent port interface

Line Interactive UPS

PC CCTV Traffic LightControl System

Work-Stations

Front Panel

PRO2000LD

5 67

8 9101112

1314

15

16

17

1819

20

1

2 4

3

The PROLiNK® PRO2000LD is a single-phase input/ single-phase output Outdoor UPS system. A wide operating temperature range of -40°C to 80°C makes it ideal for outdoor usage. Designed to put up the best performance under the harshest environment, the PRO2000LD is able to supply continuous power to critical loads during a blackout or power outage.

Equipped with dry contacts, the PRO2000LD is able to program safety-oriented signals to meet the requirements of different applications. As such, users are able to monitor UPS events that are most concerned to them. The PRO2000LD comes in a capacity of 2000VA.

For 2000VA model1. AC input terminal block2. AC input breaker3. AC output terminal block4. AC output breaker5. Input contact6. Dry contact7. Internal fan8. GND9. Battery connector10. Battery temperature sensor11. External FAN connector12. PTS control connector13. Battery breaker14. Battery voltage test points

15. Function keys16. Liquid Crystal Display (LCD)17. Indicator LEDs18. USB connector19. RS232 connector20. Intelligent slot (optional)

Page 71: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

69

Line Interactive UPS

Full Specifications

50 Hz/60 Hz (Auto sensing)170-300VAC

230VACNominal VoltageAcceptable Voltage RangeFrequency Range

Rated Power

90%95%

Waveform

Green LED FlashingGreen LED Off

Green LED OnDepending on the application

Yellow LED OnRed LED On

RS-232/USB and SNMP3A @ 250Vac

INPUT

MODELS PRO2000LD2000 VA

OUTPUT

Efficiency

Transfer Time

Liner ModeAVR Mode

90%Battery Mode12msNormal Mode (max.)25msGenerator Mode (max.)

COMPLIANCE

ENVIRONMENT

PHYSICAL

MANAGEMENT

INDICATORS

BATTERY

Class A FCC/CISPR [EN50091-2: 1995]IEEE/ANSI C.62.41 & 2KV, L-N

EMI Compliance

Bypass ModeBattery ModeNo OutputWarning with OutputFault without Output

CommunicationDry Contact Rating

<3% @ Full resistive loadOutput FrequencyVoltage Regulation (Batt. Mode)

THD (Batt. Mode)50Hz/60Hz ± 0.1%

230VAC ± 5%

Pure Sinewave

48VDC

AGM/Gel2A/4A/6A/8A/10A (Adjustable)

Nominal DC VoltageLow DC Warning VoltageBattery TypeCharging Current

230VACNominal Voltage

< 48dB-40°C to 80°C

Noise Level

Surge Protection

Operating Temperature5% to 95% Relative Humidity (Non-condensing)Operation Humidity

IP 20Type of Mechanical Protection

Dimension (mm) D × W × HNet Weight (kgs)

400 x 240 x 13312.5

46VDC ± 0.4VDC @ no load

*All specifications, designs and contents are subject to change without prior notice.

Page 72: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

70

Inverter UPS

IPS Series

Inverter Series

• Selectable Voltage Range (Except for IPS600)• Advanced Protection• Auto restart while AC is recovering• Comes with a built-in transformer (Only applies to IPS600, IPS850 & IPS1500)• LCD and/or LED panel (Refer to the specifications)

PROLiNK IPS Series is a compact home inverter system that delivers high efficiency conversion from DC to AC power. This economically ideal system provides clean and stable power for home appliances and generator related devices. In cases where the electrical utility is down, the home inverter system is able to draw DC current from the battery and supply power to all the AC loads connected to it. Covering a wide selection of sizes, the IPS Series is available in capacities as low as 600VA to as high as 5000VA.

Rear PanelFor IPS6001. AC input2. Output receptacles3. Circuit breaker4. External battery connector

For IPS700 and IPS12011. Input voltage range selector2. AC input3. Input breaker4. External battery connector5. Charge current selector6. Output receptacles

IPS600

1

3

2

4 4

1 5

6

3

44

2

IPS700/ IPS1201

Page 73: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

71

Inverter UPS

For IPS1200 and IPS24001. Operation mode selector2. AC input3. Input breaker4. External battery connectors5. Charge current selector6. Output receptacles

IPS1200/ IP2400

For IPS3000 and IPS50001. Battery connector2. Input protector3. AC input4. Inverter output

For IPS850 and IPS15001. Input voltage range selector2. AC input3. Input breaker4. External battery connector5. Charge current selector6. Output receptacles IPS850/ IPS1500

1 5

6

3

442

IPS3000 IPS3001

IPS5000

1

23 4

1

23 4

12 3 4

1

5

4 3

2

6

Page 74: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

72

Inverter UPS

Full Specifications

*All specifications, designs and contents are subject to change without prior notice.

100 – 290 VAC

90-145 VAC/180-260 VAC

(For Personal Computers)50-160 VAC/100-300 VAC

(For Home Appliances)

170-280 VAC(For Personal Computers)

90-280 VAC(For Home Appliances)

90-145 VAC/180-260 VAC

(For Personal Computers)50-160 VAC/100-300 VAC

(For Home Appliances)

170-280 VAC(For Personal Computers)

90-280 VAC(For Home Appliances)

50/60 Hz (Auto Sensing)

230 VAC 120 VAC or 230 VAC 220/ 230/ 240 VAC 120 VAC or 230 VAC 220/ 230/ 240 VACNominal Voltage

Voltage Range

VACapacity 2400VA

12 VDC3.7 VDC ± 2% 13.7 VDC ± 0.25 VDC

Not ApplicableNot Applicable

10.2 VDC ± 2%10.8 VDC ± 2%10.0 VDC ± 2% 9.9 VDC ± 2%

24 VDCBattery VoltageFloating Charge Voltage

INPUT

MODELS600VA/ 360W

IPS600850VA/ 600W

IPS8501200VAIPS1200 IPS2400

1500VA/ 1050WIPS1500

Frequency Range

BATTERY

ENVIRONMENT

PHYSICAL

ALARM

INDICATORS

PROTECTION

LED Display

LCD Display

Shutdown VoltageOvercharge ProtectionMaximum Charge Current

Full Protection

120VAC ± 10% or230VAC ± 10%

120VAC ± 10% or230VAC ± 10%230VAC ± 10%200 ~ 230VAC ± 5% 230VAC ± 10%

13 ms (Typical) 20 ms (max) 10 ms (Typical)20 ms (max) 20 ms (max) 10 ms (Typical)

20 ms (max)

AC Voltage Regulation (Batt. Mode)

Transfer Time

Waveform (Batt. Mode)

Peak Efficiency Not Applicable>95% @ Rated R loadand battery full charged >95% >95%Not Applicable

Simulated Sinewave

27.4 VDC ± 2% 27.4 VDC ± 0.5 VDCLow Battery Alarm Voltage 20.4 VDC ± 2% Not Applicable

Not Applicable30 VDC

10A or 20A (Selectable)10A or 20A (Selectable) 10A or 20A30 VDC ± 2%15 VDC

19.8 VDC ± 2%

13A 10A or 20A15 VDC ± 2%14.5 VDC ± 2%

Overload, deepdischarge, overcharge

and short circuitprotection

AC Mode, Battery Mode,Load Level, Battery Level,

Input Voltage,Output Voltage,

Overload, Fault andLow Battery

Input Voltage,Output Voltage,

Load level, Battery leveland Fault alarm

Input Voltage,Output Voltage,

Load level, Battery leveland Fault alarm

Not ApplicableNot Applicable

Not Applicable

Not Applicable

Not Applicable

Not ApplicableNot Applicable

Not Applicable

FaultLine Mode Green Lighting

Yellow Flashing Yellow FlashingYellow FlashingYellow FlashingGreen FlashingRed Flashing

Red LightingGreen Lighting

Yellow FlashingRed LightingRed Lighting

Yellow FlashingYellow FlashingYellow FlashingGreen FlashingRed Flashing

Red LightingBattery ModeLow BatteryShutdown ModeCharging ModeOverload

Low Battery Sounding every second Sounding everysecond

Sounding every2 seconds

Sounding every2 seconds

OverloadFault

Battery Replacement

Sounding every 0.5 secondContinuously sounding

Not Applicable Not Applicable Not ApplicableSounding every2 seconds

Sounding every2 seconds

Overload and short circuit protection

OUTPUT

289 x 290 x 127 293 x 231.5 xx 82.5293 x 231.5 xx 82.5358.5 x 96.8 x 146.5 289 x 290 x 127

0 to 90% Relative Humidity (Non-condensing)0°C to 40°C

-15°C to 50°C -15°C to 70°C Not Applicable Not Applicable-15°C to 70°C

HumidityOperating TemperatureStorage Temperature

2.556.99 102.354.6Dimension (mm) D x W × HNet Weight (kgs)

Simulated Sinewave Inverter

Page 75: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

73

Full Specifications

*All specifications, designs and contents are subject to change without prior notice.

Inverter UPS

170-280 VAC (For Personal Computers)90-280 VAC (For Home Appliances)

170-280 VAC (Normal Range)90-280 VAC (Wide Range)

180-270 VAC(Normal Range)

100-270 VAC(Wide Range)

50/60 Hz (Auto Sensing)

230 VACNominal Voltage

Voltage Range

VACapacity 5000VA/ 4200W

12 VDC13.5 VDC11.5 VDC10.5 VDC

24 VDC 48 VDCBattery VoltageFloating Charge Voltage

INPUT

MODELS700VA/ 500W

IPS7001200VA/ 840W 3000VA/ 2400W

IPS12013000VA/ 2400W

IPS3001IPS3000 IPS5000

Frequency Range

BATTERY

ENVIRONMENT

PHYSICAL

ALARM

INDICATORS

PROTECTION

LCD Display

Shutdown VoltageOvercharge ProtectionMaximum Charge Current

Full Protection

230VAC ± 5% 230VAC ± 10%

10 ms (For Personal Computers)20 ms (For Home Appliances)

AC Voltage Regulation (Batt. Mode)

Transfer Time

Waveform (Batt. Mode)Peak Efficiency 90% 90%95%

Pure Sinewave

27.4 VDC27 VDC 53.6 VDCLow Battery Alarm Voltage 21 VDC 42 VDC

40 VDC58 VDC

20A or 35A (Selectable)10A or 20A (Selectable)30 VDC20 VDC

10A or 15A (Selectable)15 VDC

Overload and short circuit protection

Line Mode, Line mode with charging battery,battery mode, off-mode charging, fault mode,

Low Battery, Overload, Power limitation,Fan lock and Overcharge

AC Mode, Inverter Mode, Charger Mode Load Level, Fault

Low Battery Sounding every second Sounding every 2 secondsOverloadFault

Sounding every 0.5 secondContinuously sounding

Not ApplicableNot ApplicableProtection against

misconnectionand improper usage

OUTPUT

350 x 110 x 407330 x 268 x 76268 x 330 x 76289 x 290 x 127

0 to 90% Relative Humidity (Non-condensing) 5 to 95% (Non-condensing)0°C to 50°C

-15°C to 70°C -15°C to 60°C0°C to 45°C

HumidityOperating TemperatureStorage Temperature

94.8 54.94.5Dimension (mm) D x W × HNet Weight (kgs)

Pure Sinewave Inverter

Page 76: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

74

Full Specifications

PROLiNK PVR

PVR Series

• Microprocessor control• Accepts wide input voltage range• Time delay function eliminates transient that can affect connected equipment• Provides stable output voltage• Provides under-voltage, over-voltage, over-heat and over current protection• High voltage cut off

PROLiNK PVR Series is designed to automatically maintain a constant voltage level to protect sensitive electronics from brownouts, under voltages and over voltages. The PROLiNK PVR takes efficiency to a new level with its microprocessor controller tailored to allow extremely fast response for detecting andregulating voltage. Equipped with a time-delay function, the PVR is able to protect connected devices from power-back surges. This high performance AVR comes with the versatility to fit all kinds of equipment with its wide input voltage range selection. The PROLiNK PVR provides you with the optimum solution for your everyday needs.

Auto Voltage Regulator

110VAC ~ 270VAC or 140VAC ~ 260VAC (selectable)50 or 60Hz (Auto Sensing)

Norminal VoltageVoltage RangeNominal Frequency

Capacity VAINPUT

MODELS500

PVR500 D/M1000

PVR1000 D/M2000

92%

PVR2000 D/M3000

PVR3000 D/M

220VAC

OUTPUT

Humidity

ENVIRONMENT

PHYSICAL

INDICATION

Operating Temperature

LCD/Meter Display

Dimension, D X W X H (mm)Net Weight (kgs)

220VAC± 10%

2.4 6.55 8.563.91

95%

VoltageOutput Voltage Regulation

Normal ModeAVR Mode

10 secondsOver-voltage, under-Voltage, over-heat and over current Protection

Normal indicator, AVR indicator, delay time setting and Fault indicatorInput and Output voltage

196.8 x 110 x 123.5 233.6 x 134 x 181 297.1 x 150 x 199

0°C - +40°C0-90% relative Humidity (Non-condensing)

Delay TimeFull Protection

PROTECTION

EFFICIENCY

LED Display

D = LCD display, M = Analogue display*All specifications, designs and contents are subject to change without prior notice.

Page 77: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

75

DC UPS

Full Specifications

160 - 280VAC50 or 60Hz

220VACNominal VoltageVoltage RangeFrenquency

12V9AH x 1Battery TypeCharging VoltageCharging CurrentTypical Recharge Time

INPUTMODELS PDC50

OUTPUT

BATTERY

AC ModeBattery Mode

EFFICIENCY

ENVIRONMENT

PHYSICAL

PROTECTION

Battery ModeLow BatteryFault

INDICATIONAC Mode

10V ~ 13.7V0ms

>75% at Nominal Voltage (Battery Fully Charged)>95% at Full Load

Output Voltage RegulationTransfer Time

13.7V ±0.25V 2.8A or 2.3A at Nominal Voltage without Load

Back to 90% capacity in 4-6 hours

Green LightingYellow Lighting

Red LightingYellow Flashing

Full Protection Short Circuit and Overload Protection

12VDCNominal Voltage

228 x 82.5 x 207

0 ~ 90%0°C ~ 40°C

HumidityTemperature

3Dimension (mm) D x W × H @ Vertically StandNet Weight (kgs)

PROLiNK DC UPS

PDC Series - DC UPS

• Dual DC Outputs• Microprocessor control guarantees high reliability• Compact size for standing and mounting flexibility• Supports solar powered devices and communication applications• Auto restart while AC is recovering• Off-mode charging• Overload protection and short circuit protection

PROLiNK PDC series is a compact DC UPS system that converts AC to DC power. This device comes with a built-in dynamic voltage regulator that ensures the voltage from the power source is kept within acceptable limits. The PDC Series is ideal for devices such as switches, hubs, routers and modems. With the built-in DC start function, the PDC UPS can be started up with the absence of AC power. The PROLiNK PDC series is definitely your number one choice for back-up power solution.

Page 78: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

76

Full Specifications

PROLiNK DC BACK-UP UNIT

PBU Series

• DC-powered outlets for 11watts energy saving bulb• 3 sets DC-powered outlets for energy saving light bulbs• Off mode charging• Overload protection in battery mode and short circuit protection• LED indication• 3-step charging design for extended battery life

PROLiNK Back-Up (PBU) unit is a user-friendly lighting power supply unit that is suitable for home/ outdoor settings. This portable-sized unit is compact in size but it comes with a powerful 230VDC output that can be used for powering up energy saving light bulbs of up to 11W. The unit is designed with the flexibility to be powered by regular AC supply or via the supplied battery. The PROLiNK PBU unit’s potential is best realized for users that commonly experience power blackouts.

The unit is also brilliantly designed to allow a range of flexible display methods: vertically or horizontally standing, wall-mounted or as a portable display; as well as a choice to select between a B22 or E27 light bulb terminal. The PROLiNK Back-Up unit is the perfect cost-effective solution for your lighting requirements.

DC UPS

100VAC – 300VACVoltageVoltage Range

Rated PowerINPUT

MODELS50VA

PBU5022 / PBU5027

Back to 90% capacity in 6 hours

220VAC

OUTPUT

Humidity

OPERATING ENVIRONMENT

PHYSICAL

PROTECTION

Operating Temperature

Dimension, D X W X H (mm)Net Weight (kgs)

230VDC160-230VDC ± 10%

DC Output

2.7

230 VAC12V 7Ah x 1

12VDC

2-pin Sockets

Battery Type and NumberBattery Voltage

Output Voltage (Batt. Mode)Waveform

Output Voltage (AC Mode)

Typical Recharge Time

Battery Mode – Yellow LightingAC Mode – Green Lighting

Output Short-circuited – Red LightingCharging Mode – Green flashing every 2 seconds

Low Battery – Yellow flashing every secondOverload – Red Flashing every 0.5 seconds

Red LED staying on for one second and off for 4 seconds

Overload Protection and short circuit protection

209 x 87 x 200

0°C to 40°C0-90% relative Humidity (Non-condensing)

LED Display

INDICATORS

BATTERY & CHARGER

Full Protection

Backup Time Table:

PBU5022 = for B22 light bulb terminal.PBU5027 = for E27 light bulb terminal.*All specifications, designs and contents are subject to change without prior notice.

11W Safe Energy Light Bulb x 1 no

11W Safe energy light bulb x 2 nos

11W Safe energy light bulb x 3 nos

11W Safe energy light bulb x 4 nos

Up to 6 hours

Up to 2 hours

Up to 3 hours

Up to 1.5 hours

B22 Connector E27 Connector

Page 79: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

77All specifications, designs and contents are subjected to changes without prior notice.The above Battery back-up calculation is based on estimated values and will be subject to change (Variables include; load consumption, sunshine duration and PV panel peak power supply).

Solar

PROLiNK Solar Inverter

Zonne Series

• 450W Inverter• PWM technology solar charger• Off mode charging• Overload protection and short circuit protection in battery mode• Universal socket

PROLiNK Zonne 450 unit is a compact and user-friendly solar power unit that is suitable for use in home like settings. The Zonne series is designed with a built-in charger controller that facilitates proper charging of the battery; enhancing the overall lifespan of the battery.

Also, the PROLiNK Portable Solar unit comes with the flexibility to be powered by regular AC supply, solar PV modules or via the supplied battery. The Zonne unit is capable of supporting up to one block of 100AH battery, giving users ample amount of power supply to operate multiple home appliances.

External Battery

Solar Panel

Utility Supply

Home Appliance

Backup Time Table:Battery Type Effective Sunshine Duration Application / Load Battery back-up

1 block x 12V40AH 5 hours

2 x energy saving light bulb 8 hours per day

1 x energy saving light bulb1 x Fan

6 hours per day

2 x energy saving light bulb1x Fan

4 hours per day

Battery Type Effective Sunshine Duration Application / Load Battery back-up

1 block x 12V65AH 5 hours

2 x energy saving light bulb 10 hours per day

1 x energy saving light bulb1 x Fan

8 hours per day

2 x energy saving light bulb1x Fan

6 hours per day

Page 80: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

78*All specifications, designs and contents are subjected to changes without prior notice.*Above mentioned Back-up timetable is for reference purpose only.

Solar

Full Specifications

90 or 280VAC (INV. Mode)162 - 290VAC (UPS Mode)

220/ 230/ 240VAC

Zonne 450

Voltage

450WRated Power

Voltage Range

12VDC

10Amp

Battery Voltage

Floating VoltageMaximum Charge Current

AC INPUT

MODELS

OUTPUT

BATTERY & CHARGER

PROTECTION

PHYSICAL

INDICATORSLine ModeBattery ModeLow BatteryShutdown ModeCharging Mode at Power OnCharging Mode at Power OffOverloadOverchargingFault

Simulated SinewaveVoltage Regulation (Batt.Mode)Waveform

Full Protection Overload and Short Circuit Protection

13.4VDC ± 1.5%

Green LightingYellow Lighting

Yellow Flashing every 2 secondsYellow Flashing every 5 secondsGreen Flashing every 2 secondsGreen Flashing every 5 seconds

Red Flashing for 0.5sec. every secondsRed Flashing every 5 seconds

Red lighting

230VAC±10%

Output Voltage

293 x 231.5 x 82.52.35

Dimension (mm) D x W × HNet Weight (kgs)

SOLAR CHARGER10Amp12VDC

Charging CurrentSystem Voltage

Page 81: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

79

PROLiNK PORTABLE SOLAR

PPS Series

PPS70• DC-powered outlets for 11watts energy saving bulb• 3 x 5V USB charging ports for mobile phones• PWM technology solar charger• Off mode charging• Overload and short circuit protection in battery mode• 12VDC round pin connector output for 12VDC equipment• Option for lamp holder with 2m cable• Option for 24W Solar PV panel

PROLiNK Portable Solar (PPS) unit is a compact and user-friendly lighting solar power supply unit that is suitable for use in home / outdoor settings. Thisportable-sized unit is compact in size but it can be used for powering up energy saving light bulbs of up to 11W. In addition, there is also a 5VDC USB port for charging your mobile devices and a 12VDC round pin connector for equipment such as DC fans.

PROLiNK Portable Solar unit provides you the option of doubling up your backup duration by adding another block of 7AH battery on top of the existing supplied battery. The PPS is the perfect device for users living in rural locations where the power supply is ofteninconsistent and unstable.

Solar

Solar

Mobile Phone

Utility Supply

12VDC Supply

3 Outlet For Energy Saving Bulb

External Battery

PPS70M• 11W DC UPS• Built-in 3 watts LED.• 12VDC-powered outlets for 11watts energy saving bulb• 1 x 5V USB charging ports for mobile phones• PWM technology solar charger• Off mode charging• Overload and short circuit protection in battery mode• Lamp holder with 5m cable• 16W Solar PV panel

Solar

Mobile Phone

1 Outlet For 3watt LED Light Bulb

PPS70M

PPS70

Page 82: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

80

Solar

Full Specifications

*All specifications, designs and contents are subject to change without prior notice.

2AMaximum PV Array Open Circuit VoltageMaximum Solar Charging Current

PV INPUT MODELS PPS70

12VDC 2A x 1 pc5VDC 1A x 3 pcs

Not Applicable

30VDC

AC INPUT

Humidity

OPERATING ENVIRONMENT

PHYSICAL

PROTECTION

Operating Temperature

Dimension, D X W X H (mm)Net Weight (kgs)

230VAC50 Hz or 60 Hz (auto sensing)

3.8

230VDC160-230VDC ± 10%

DC Output

VoltageFrequency Range

2-pin Sockets Output Voltage (Batt. Mode)Waveform

Output Voltage (AC Mode)

DC ConnectorUSB Charger

12V 7Ah x 1 (Optional external battery) Not Applicable12VDC

Back to 90% capacity in 8 hours

Overload Protection and short circuit protection

229 x 110 x 123.5

0°C to 40°C0-90% relative Humidity (Non-condensing)

1A

PPS70M

Not Applicable5VDC 1A x 1 pc

3W

Not Applicable

Not Applicable12VDC

Back to 90% capacity in 4-6 hours

Battery Type and Number

Power

Battery VoltageTypical Recharge Time

BATTERY & CHARGER

LED LIGHT (Built-in)

OUTPUT

Full Protection

Page 83: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

81

PROLiNK Solar System

PCC Series

• Intelligent Maximum Power Point Tracking technology• Built-in DSP controller with high performance• Automatic battery voltage detection• Multi-functional LCD • Reverse polarity protection for solar panel and battery• Overcharge and overload protection• Suitable for battery types such as sealed lead acid, vented Gel and NiCd• Standard RJ45 port or optional RS-485 communication port for remote monitoring

*All specifications, designs and contents are subject to change without prior notice.

PCC Series is a Solar Installation System that combines thebenefits of both the Maximum Power Point Tracking (MPPT) technology and DSP controller system. The MPPT enhances the PCC Series by transferring the most power from its PV solarmodules and the DSP controller system provides a high level of computational performance for real-time signal processing in the solar power inverters. This allows your solar panels to operate at their optimum power output voltage, thereby increasing the level of efficiency to 97.7% and at the same time lowering power loss.

Users can start generating green energy for their home applications by integrating the PCC Series with solar panels, inverter andexternal battery packs. Batteries are compatible with up to 4 types; sealed lead acid, vented, gel and NiCad.

Solar

Solar PanelPCC300

External Battery Packs

Inverter

Home Appliances

Page 84: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

82

Full Specifications

*All specifications, designs and contents are subject to change without prior notice.

Solar

75V 145VDC50V

18AMaximum PV Array Power

50A

30 ~ 66V @ 24V 60 VDC ~ 115 VDC 15 ~ 33V @ 12VMPPT Range @ Operating VoltageMaximum PV Array Open Circuit Voltage

Maximum CurrentMaximum Array

>110%: Audiable Alarm YesOverload ProtectionOvercharge ProtectionPolarity Reversal Protection @ Solar Cell & Battery

INPUTMODELS PCC600 PCC3000PCC300

OUTPUT

PROTECTIONS

ENVIRONMENT

PHYSICAL

INDICATIONLCD Panel

LED Display

Sealed Lead Acid, Vented, Gel, MiCd Battery

<±1V

Three Stages: Bulk, Absorption & Floating

25A 60A

98%

Three indicators: Solar, Charging & Load Status Three indiators: Solar, Battery &Wiring Fault

98%

IP43 IP31

Connected Battery TypeMaximum Charging CurrentRipple VoltageMaximum EfficiencyStanby Power ConsumptionCharging Method

YesYes

LCD Panel indicating Solar Power, Output Power, Battery Voltage, Charging Current, and Fault Conditions

24V 12V 24V 48V12V

1W 2W

Nominal Battery Voltage

220 x 170 x 57.5

Input or Output Terminal Block

315 x 165 x 128135 x 170 x 57.54.50.92

0~90% Relative Humidity (Non-condensing) 5~95% Relative Humidity(Non-condensing)

-20°C to 55°C-40°C to 75°C

0 ~ 3000m

Humidity

Operating TemperatureStorage TemperatureAltitude

1.85Dimension (mm) D x W × HNet Weight (kgs)ConnectorType of Mechanical Protection

800W 1600W 3200W

Page 85: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

83

• Works as an On-grid inverter during the day• Works as an Off-grid inverter during the night or rainy conditions• Pure sine wave output• Multiple operations: Grid tie, Off grid, and grid-tie with backup• Built-in MPPT solar charger• LCD display panel for comprehensive information

Full Specifications

PROLiNK Solar System

PSI HybridHYBRID SeriesPSI Hybrid Series is a hybrid inverter that combines the solar power system, AC utility and battery power source to supply continuous power to your home / office applications. This device is most suitable for rural areas where electrical supply is unstable and inconsistent. The PSI Hybrid series comes with a grid-tie operation mode where surplus electricity can be fed back to the main grid, making it an economic and cost-effective power option. If gaining access on the grid is not possible, the PSI Hybrid Series also comes with an off-grid operation mode where power can be stored directly to the back-up battery; making the Hybrid series one of most versatile solar inverters in the market.

Solar

250 VDC ~ 450VDC 400 ~ 800VDC720VDC360VDC

116VDC / 150VDC 320VDC / 350VDC13A 18A 18.6A x 2

500VDC 900VDCMaximum DC VoltageMPP Voltage RangeDC Nominal VoltageStart-up Voltage / Initial Feeding VoltageMaximum Input Current

Phase

47.5 ~ 50.2HzAC Grid Frequency RangeNominal AC Voltage/ Range

Nominal Output CurrentPower Factor

PV INPUT

MODELS HYBRID 3KSingle Phase

HYBRID PRO 3KThree PhaseHYBRID 10K

GRID/ UTILITY INPUT (AC)

GRID OUTPUT (AC)

ENVIRONMENT

INTERFACE

PHYSICAL

BATTERY & CHARGENominal DC VoltageMaximum Charging Current

BATTERY MODE OUTPUT (AC)Output VoltageOutput FrequencyOutput WaveformEfficiency (DC to AC)

30A 25A

220VAC / 184~265VAC 400VAC / 320~460VAC

Maximum Input Current

13A 14.5A>0.99 -

202/ 208/ 220/ 230/ 240VAC 400VAC50Hz / 60Hz (auto sensing)

Pure Sinewave93% 96%

48VDC25A 200A

Dimension (mm) D x W × H 107 x 438 x 480 622 x 500 x 167.5Net Weight (kgs) 15.5 45

208/ 220/ 230/ 240VAC170 ~ 280VAC 170 - 280VAC

400VACSingle Phase Three PhasePhase

Nominal AC Voltage/ RangeAcceptable Voltage Range

RS-232 / USB

0~90% (Non-condensing)

0 ~ 1000m-10°C to 55°C0°C~40°C

Operation Humidity

AltitudeOperating Temperature

Optional SNMP, Modbus and AS-400 cards availableCommunication PortIntelligent Slot

** Upcoming product. This category is for products to be released in the future. Please contact PROLiNK for more details.*All specifications, designs and contents are subject to change without prior notice.

Page 86: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

84

Full Specifications

PROLiNK Solar System

PSI On-GridAMNETZ Series

• 1.5KW/2KW/3KW/5KW & 3-phase 10KW on-grid PV inverter• Advanced DSP control technology delivers accurate data• Smart MPPT technology enhances overall efficiency• Modular design for easy maintenance• Industrial-grade components used for robust operation• Up to 15 years of data logging• Ingress Protection rated 65 (good for any type of environmental conditions)• Comprehensive LCD monitor for easy-reading• Free monitoring software

PSI On-Grid Series is a grid-connected photovoltaic power system that is designed to operate at its optimum power output voltage even under unfavourable weather conditions. This device uses high quality Amnetz PV inverters to convert DC to AC power at a maximum conversion efficiency of up to 96%. On top of that, this user-friendly device is bundled with a monitoring software kit that allows users to observe from agraphical overview of the module voltage/current and temperature.

Solar

*All specifications, designs and contents are subject to change without prior notice.**Upcoming product. This category is for products to be released in the future. Please contact PROLiNK for more details.

500VDC150 ~ 500VDC

370VDC 600VDC360VDC125/ 150VDC120/ 150VDC

11A 13A 2 x 15A 2 x 17A / 17A250/ 250VDC

Maximum DC VoltageMPP Voltage RangeNominal DC VoltageStart-up Voltage/ Initial Feeding VoltageMaximum Input Current/ Per String

Phase

Maximum Efficiency

DC Reverse-Polarity ProtectionGround Fault Monitoring

INPUT (DC)

MODELS AMNETZ 1500 AMNETZ 20001 Phase-In 1 Phase-Out

>0.99

3 Phase-In 3 Phase-OutAMNETZ 3000 AMNETZ 5000

450VDC 500VDC 500VDC 900VDC

230VAC 230VAC 230VAC 3/ N/ PE, 230/ 400VAC

6.6A 8.7A 20A 14.5A

150 ~ 400VDC 200 ~ 450VDC 320 ~ 800VDC

AMNETZ 10K**

OUTPUT (AC)

EFFICIENCY

COMPLIANCE

ENVIRONMENT

INTERFACE

PHYSICAL

Intelligent Slot

PROTECTION

AC Short Circuit ProtectionGrid Monitoring

Dimension (mm) D x W × HNet Weight (kgs)

230VAC184 - 264VAC* -20% ~ +15%*

50Hz / 60Hz13A

Nominal AC VoltageAC Voltage RangeAC Grid FrequencyNominal Output CurrentPower Factor

96.0% 97% 98.0%

YesYesYesYes

160 x 270 x 450 182 x 308 x 515 171.2 x 503.5 x 653.3136.5 x 268.5 x 41020 4011.5 15

USB Card/ Optional: SNMP, RS-232, AS-400 and GPRS Cards

Operating TemperatureHumidity

-25 ~ 60°C-25 ~ 60°C0 ~ 100% Relative Humidity (nNon-condensing)

Altitude 0 ~ 1000m (Power derating 1% every 100m when altitude is over 1000m)

CE, VDE-AR-N 4105, VDE-0126-1-1, IEC62109Standard

Page 87: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

170 - 280VAC (For Personal Computers)90 - 280VAC (For Home Applicances)

50 Hz / 60 Hz (Auto Sensing)

Voltage

Selectable Voltage Range

Frequency Range

Rated PowerINPUT

MODELS HAUS 1000 HAUS 2000

Pure sine wave

HAUS 3000 HAUS 4000

2000VA 4000VA 8000VA 10000VA

230VAC

HAUS 5000

OUTPUT

Storage Temperature

Net Weight (kgs)

PHYSICAL

SOLAR CHARGER (OPTION)

Dimension, D X W X H (mm)

Maximum Charge Current

Charging CurrentMaximum PV Array Open Circuit Voltage

230VAC ± 5 %6000VA

5.0 6.4 9.86.9

93%10 ms (For Personal Computers)

AC Voltage Regulation (Batt. Mode)Surge PowerEfficiency (Peak)Transfer TimeWaveform

12VDC 24VDC 48VDC13.5VDC 27VDC 54VDC15VDC 30VDC 60VDC

10A or 20A 20A or 30A 20A or 30A

50A60VDC 90VDC30VDC

100 x 272 x 35595 x 240 x 316 120 x 295 x 468

HumidityOPERATING ENVIRONMENT

5% to 95% Relative Humidity (Non-condensing)Operating Temperature 0°C to 55°C

-15°C to 60°C

Battery VoltageFloating Charge Voltage

BATTERY

Overcharge Protection

1kVA / 800W 2kVA / 1.6kW 3kVA / 2.4kW 4kVA / 3.2kW 5kVA / 4kW

85

Full Specifications

PROLiNK Solar System

PSI Off-GridHAUS Series

• Pure sine wave inverter• Selectable input voltage range• Selectable charging current• Utility or Solar input priority configuration via LCD setting• Generator compatible• Auto restart while AC is recovering• Overload and short circuit protection• Cold start function• Optional N+1 parallel redundancy

The PSI HAUS Series is a wall-mounted off grid PV inverter that employs a PWM technology. It is best used in remote locations without utility services. The device is able to supply generous amount of electrical power to the load via PV modules, battery sources and AC powered sources. The HAUS Series is able to fully utilize the energy from the sun to convert stable electrical power to any home / commercial applications. In the event where it isinapplicable to draw power from PV modules and battery sources, an AC power source can still be supplied by a generator to get you through a rainy day.

Solar

*All specifications, designs and contents are subject to change without prior notice.

Page 88: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

86

Solar

• Pure sine wave inverter • Built-in MPPT solar charge controller• Selectable input voltage range for home appliances and personal computers • Selectable charging current based on applications • Configurable AC/Solar input priority via LCD setting • Compatible to mains voltage or generator power • Auto restart while AC is recovering• Overload and short circuit protection• Smart battery charger design for optimized battery performance• Cold start function• Parallel operation with up to 6 units only available for 4KVA/5KVA• Optional Remote Control Panel available

PROLiNK Solar System

PSI Off-GridHAUS MPPT Series

The PSI HAUS MPPT Series is a wall-mounted off grid PV inverter that employs a MPPT technology. It is best used in remote locations without utility services. The device is able to supply generous amount of electrical power to the load via PV modules, battery sources and AC powered sources. The HAUS MPPT Series is able to fully utilize the energy from the sun to convert stable electrical power to any home / commercial applications. In the event where it is in applicable to draw power from PV modules and battery sources, an AC power source can still be supplied by a generator to get you through a rainy day.

HAUS PLUS2KM/ 2KMHDC/3KM/ 3KMHDC

HAUS4KMHDC/ 5KMHDC

HAUS1KM/ 1KMHDC/ 2KM/ 3KM/ 3KMHDC

Page 89: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

87

Solar

Best Panel Configuration

Inverter Power 800W25Amp, 600W

500Wp(250Wp x 2pcs)

1000Wp(250Wp x 4pcs)

500Wp(250Wp x 2pcs)

500Wp(250Wp x 2pcs)

1500Wp(250Wp x 6pcs)

3000Wp(250Wp x 12pcs)

3000Wp(250Wp x 12pcs)

20Amp, 900W 25Amp, 600W 25Amp, 600W 20Amp, 900W 60Amp, 3000W 60Amp, 3000W1000W 1600W 2400W 2400W 4000W

Pmax. Generated From Solar Charger

MODELS HAUS1KM

HAUS1KMHDC

HAUS2KM

HAUS3KM

HAUS3KMHDC

HAUS5KMHDC

3200W

HAUS4KMHDC

Full Specifications

50/60 Hz (Auto sensing)

170-280 VAC (For Personal Computers)90-280 VAC (For Home Appliances)

230 VACVoltage

Selectable Voltage Range

Frequency Range

Capacity 1000VA/ 800W 1000VA/ 800W 2000VA/ 1600W 3000VA/ 2400W 3000VA/ 2400W 5000VA/ 4000WINPUT

MODELS HAUS1KM

HAUS1KMHDC

HAUS2KM

HAUS3KM

HAUS3KMHDC

HAUS5KMHDC

4000VA/ 3200W

HAUS4KMHDC

OUTPUT

Operating Temperature

PHYSICAL

MPPT Range @ Operating Voltage 30VDC ~ 66VDC75 VDC 102 VDC 75 VDC 102 VDC 145 VDC

60VDC ~ 88VDC 30VDC ~ 66VDC 60VDC ~ 88VDC 60VDC ~115VDC

Dimension, D x W x H (mm)

ENVIRONMENTHumidity 5% to 95% Relative Humidity(Non-condensing)

0°C - 55°C

Maximum PV Array Open Circuit Voltage

2000 VA 4000 VA 6000 VA 8000 VA 10000 VA

24 VDC

Surge Power

BATTERY & AC CHARGER

Efficiency (Peak)Transfer TimeWaveform

Battery VoltageFloating Charge VoltageOvercharge ProtectionSOLAR CHARGER & AC CHARGER

31 VDC

Maximum PV Array Power

Maximum Solar Charge CurrentMaximum AC Charge Current

Maximum Charge Current

Maximum EfficiencyStandby Power Consumption

93%90% - 93%10 ms (For Personal Computers); 20 ms (For Home Appliances)

Pure sine wave

600 W 900 W 600 W 900 W 3000 W

25A20A 15A 30A 15A 60A

120A120AAC charger and solar charger can’t work at the same time.

18A30A

98%2 W

18A25A

18A 25A 18A 60A

27 VDC48 VDC

62 VDC54 VDC

24 VDC

31 VDC27 VDC

48 VDC

62 VDC54 VDC

60 VDC

100 x 272 x 355 120 x 295 x 4687.06.8 117.4Net Weight (kgs)

230VAC ± 5%AC Voltage Regulation (Batt. Mode)

-15°C - 60°CStorage Temperature

Page 90: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

88

Best Panel Configuration

Inverter Power 1600W60Amp, 1500W

1500Wp (250Wp x 6pcs) 3000Wp (250Wp x 12pcs)60Amp, 3000W 60Amp, 1500W 60Amp, 3000W

1600WPmax. Generated From Solar Charger

MODELS HAUS PLUS2KM

HAUS PLUS2KMHDC

HAUS PLUS3KM

HAUS PLUS3KMHDC

There are charging current selection only available for 230VAC system.*All specifications, designs and contents are subject to change without prior notice.

Solar

50/60 Hz (Auto sensing)

170-280 VAC (For Personal Computers)90-280 VAC (For Home Appliances)

95-140 or 170-280 VAC (For Personal Computers)65-140 or 90-280 VAC (For Home Appliances)

230 VAC120 VAC or 230 VACVoltage

Selectable Voltage Range

Frequency Range

Capacity 2000VA/ 800W 2000VA/ 1000W 2000VA/ 1600W 3000VA/ 2400WINPUT

MODELS HAUS PLUS2KM

HAUS PLUS2KMHDC

HAUS PLUS3KM

HAUS PLUS3KMHDC

OUTPUT

Operating Temperature

PHYSICAL

MPPT Range @ Operating Voltage145 VDC

30~115 VDC or 60~115 VDC 60~115 VDC 30~115 VDC or 60~115 VDC 60~115VDC

Dimension, D x W x H (mm)

ENVIRONMENTHumidity 5% to 95% Relative Humidity(Non-condensing)

0°C - 55°C

Maximum PV Array Open Circuit Voltage

4000 VA 6000 VA

24 VDC

Surge Power

BATTERY & AC CHARGER

Efficiency (Peak)Transfer TimeWaveform

Battery VoltageFloating Charge VoltageOvercharge ProtectionSOLAR CHARGER & AC CHARGER

31 VDC

Maximum PV Array Power

Maximum Solar Charge CurrentMaximum AC Charge CurrentMaximum EfficiencyStandby Power Consumption

90% - 93%10 ms (For Personal Computers); 20 ms (For Home Appliances)

Pure sine wave

1500 W 3000 W 1500 W 3000 W

20A or 20A / 30A 10A or 10A / 15A 20A 30A 10A / 15A98%2 W

60A

27 VDC48 VDC

62 VDC54 VDC

48 VDC

31 VDC54 VDC

24 VDC27 VDC

62 VDC

140 x 295 x 47911.5Net Weight (kgs)

230VAC ± 5%110/120 VAC ± 5% (User Selectable) or 230VAC ± 5%AC Voltage Regulation (Batt. Mode)

-15°C - 60°CStorage Temperature

Page 91: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

89

Full Specifications

8A50/60Hz

170~280VAC

60A

110~300VACNominal Frequency

Nominal Voltage

Input Current (max) @ full load

Voltage Range

INPUTMODELS PEC20-24

230VAC

PEC15-36 PEC15-48 PEC12-72 PEC10-96 PEC24-240

OUTPUT

EFFICIENCY

PROTECTION

ENVIRONMENT

PHYSICAL

INDICATION

IP20IP ClassNoise Level

LED Display N/A

Up to 85%

Floating Charging Voltage

AC Mode

27.3VADC

24VDC

Full Protection Over-voltage, Thermal control, Over current, Short circuit, Reversal polarity

Charger ON – Green LEDBoost Charging Status – Yellow LED

Floating Charging Status – Green LEDLow Charging Voltage – Red LED

20A82.2VDC

72VDC12A

109.6VDC

96VDC10A

273.6VDC

240VDC24A

41.1VDC

36VDC

54.8VDC

48VDC15AOutput Current (max)

Nominal Voltage

570 x 250 x 215300 x 177 x 90

0 ~ 40°C<50dB

Operation Temperature<95% (Non-condensing)Relative Humidity

143.1Dimension (mm) D x W × HNet Weight (kgs)

PROLiNK Online UPS Accessories

External Battery Charger (PEC)

• Input PFC control• Back feed protection• Three-stage smart charging• Short circuit and over voltage protection• Maximum current restriction• Redundancy operation

PROLiNK External Charger (PEC) is an additional external smart charger for PROLiNK Online UPS system. It designed withisolation structure and operated in parallel with several units for charging capability expandable.

With PROLiNK External Battery Cabinet

Expandable PROLiNK battery cabinets

UPS Expandable Charger units

Expandable battery units

UPS Expandable Charger units

With External Battery Bank

All specifications, designs and contents are subjected to changes without prior notice.

Software & Accessories

Page 92: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

90

• 16A maximum input current• Powered by two separate independent power sources• Dual power supply for redundancy• Provides seamless power switch for IT equipment• Preferred source selection on front panel• 19” rack-mount design (1U)• Built-in USB and RS-232 interface

Full Specifications

PROLiNK Online UPS Accessories

Automatic Transfer Switch

PROLiNK Automatic Transfer Switch (ATS) is designed to allow two independent power inputs to supply power to the connected load. In the event where the primary power source fails, the ATS automatically transfers the backupconnection to the secondary power source without any interruption, providing seamless electrical power and the highest protection for your equipment. The PROLiNK ATS is also designed to automatically transfer the connection back to the primary power source once it has detected restored power.

*All specifications, designs and contents are subject to change without prior notice.

207 ~ 253VAC50Hz/ 60Hz

230VACInput VoltageAcceptable Input VoltageInput Frequency

Current Rating

8xIEC-C13; 1xIEC-C19OutputInput

CommunicationTransfer Time

INPUT

MODELS16A

ATS16-R

OUTPUT

CONNECTION

ENVIRONMENTOperating Temperature

PHYSICALDimension (mm) D x W x HNet Weight (kgs)

10A for IEC-C13 Outlets; 16A for IEC-C19 Outlets

2xIEC-C20 Inlets

Maximum Output Current

USB/ RS-2329 ~ 12ms (Typical)

310 x 430 x 443.65

20 ~ 95% Relative Humidity @ -5°C ~ 45°C (Non-condensing)

230VACOutput Voltage

Software & Accessories

Page 93: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

91

• 16A for 208/220/230/240 VAC• Provides continuous power to connecting equipment during UPS maintenance• Easy operation with simple rotary switch and indicators• Master-slave function for energy saving• Multiple sockets to support more devices• Choose between a rack or tower design to fit into any working environment• Simple installation with plug-and-play socket type• Suitable for all UPSs up to 3kVA

Full Specifications

PROLiNK Online UPS Accessories

PDU & Maintenance Bypass Switch

The PDU & Maintenance Bypass Switch is an external powerdistribution unit used in conjunction with UPS systems or large-scale voltage regulators. This device enables the UPS to be isolated for scheduled maintenance or replacement withoutinterrupting the power to the load. Designed with amaster-controller concept, the PROLiNK PDU is able to handle both the maintenance bypass function and power saving function effectively.

I = IEC, U = UK, S = EU, N = Nema*All specifications, designs and contents are subject to change without prior notice.

IEC UK NEMASchuko

Yes. When power consumption in Master Outlet is lowerthan 20W (±5W), it will shut off the power for slave outlets. NAMaster/ Slave Function

Current Rating

5 x NEMA 20A Sockets 6 x NEMA 20A SocketsPHYSICAL

Voltage Rating 208/ 220/ 230/ 240/VAC

MODELS16A

MBS16-R (I/U/S/N) (*) MBS16-T (I/U/S/N) (*)

Output

Net Weight (kgs)

CONNECTION

ENVIRONMENTOperating Temperature

Dimension (mm)D x W x H

IECSchukoUKNEMA

5 x IEC 10A Socket + 1 x IEC 16A Socket (with 2 circuit breakers) 8 x IEC 10A Socket + 1 x IEC 16A Socket (with 2 circuit breakers)

4 x Schuko 16A Sockets4 x UK 13A Sockets

80 x 438 x 50 180 x 160 x 50

80 x 438 x 60 180 x 200 x 50

80 x 438 x 50 180 x 160 x 501.50 1.30

20 ~ 95% Relative Humidity @ -0°C ~ 40°C (Non-condensing)

1 x IEC (16A) Connector & 1 x Customized Plug Cable

1 x IEC (16A) Connector & 1 x Cable (16A ~ 10A IEC Cable for 1k/ 2k, 16A ~ 16A IEC cable for 3k)Input

NEMAUK

UPS Input

SchukoIECUPS Output

AC Power

Software & Accessories

Page 94: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

92

• Allows control and monitoring of multiple UPSs through RJ-45 network connection• Real-time dynamic graphs reflecting UPS data (Voltage, frequency, load level and battery level)• Warning notifications via audible alarm, broadcast, mobile messenger, e-mail and SNMP traps• Historical data logging• One click easy firmware upgrade• Password security protection and remote access management• Supports optional environmental monitoring detector for temperature, humidity and smoke

PROLiNK Online UPS Accessories

SNMP CardIntegrated with our latest ViewPower software, the SNMP manager operates as an enhanced communication solution for your UPS system. It allows you to remotely manage and monitor your UPS system via internet connectivity. Once connected to the internet, the ViewPower software provides you access to remotely program or even shut down your UPS system.

• Adopts ModBus RTU Protocol• Comes with functions that includes read Holding Registers and write Registers• RS232 and RS485 interface

Modbus CardThe ModBus Card provides UPS and PV inverter systems with the functionality to communicate with PCs through the ModBus Protocol.

• Capable of selecting the status of the dry-contact signal by setting the jumper to meet different application requirements• Suitable applications include; IBM Server, Personal PC & Workstations equipments, Auto-controlled industrial equipment & communication applications

AS-400 CardThe AS-400 communication card is designed with a high quality contact closure board that accurately converts UPS signals into dry contacts for users to monitor UPS events that are most concerned to them. By setting the jumper, the AS-400 communication card allows you to select various status indicators such as; UPS alarm, UPS failure, Bypass, Low Battery etc.

• Simple and easy installation• Suitable for PROLiNK Rack Mount Online UPS system• Slider length available in 700mm and 1100mm to suit different types of cabinet

Rack Mount SliderThe PROLiNK Rack-mount slider kit offers you the best solution to install a PROLiNK UPS system into a 19” server rack enclosure. This kit comes with a pair of heavy duty sliders that are attached with quality assured ball bearings to ensure that your server can slide effortlessly into and out of the rack. Furthermore, the PROLiNK Rack-mount slider kit includes a superior quality front and rear mounting brackets to withstand the weight of your UPS.

Software & Accessories

Page 95: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

93

• Allows control and monitoring of multiple UPSs via LAN and INTERNET• User-friendly power analysis graphs• Real-time dynamic graphs of UPS data• Safety OS shutdown to prevent data losses during power failure• Warning notifications via audible alarm, broadcast, mobile messenger, and e-mail• Scheduled UPS on/off, battery test, programmable outlet control, and audible alarm control• Password security protection and remote access management• Supports multiple OS and local languages

PROLiNK Online UPS Software

Viewpower – UPS Management SoftwareViewPower is an advanced UPS management software that is designed for users to remotely monitor and manage multiple UPS units in a networked environment, either by LAN or INTERNET. The ViewPower software is able to protect your important data by executing a safety OS shutdown during power failure. Better yet, this software gives users the ability to store programming data and also scheduled a UPS shutdown when necessary.

• Allows control and monitoring of multiple devices via LAN and INTERNET• Automatic and real-time data acquisition• Secure data logging• Graphic display of device data for quick and easy reading• Warning notifications or fault alarms via audible alarm, pop-up screen, broadcast, mobile messenger, tray message and e-mail• Easy diagnosis from event statistics and amount calculation for energy saving• Maximum data log up to 10 billion records• Supports online upgrade and manually upgrade• Supports multiple languages: English, Chinese, French, German, Spanish, Russian, Portuguese, Ukrainian, Italian, Polish

Solar Power Management SoftwareSolarPower Pro is a solar inverter monitoring software that is capable of monitoring up to 247 devices via a modbusinterface. When connected to a networking environment, users are able to monitor the Solar inverter via a web browser. The SolarPower Pro comes with a variety of features including; data logging, ability to generate statistical data, alarmnotifications, prompting fault messages and parameter control for devices.

Software & Accessories

Page 96: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

94

PROLiNK UPS Battery Backup Configuration List

1. Professional Series (1P/1P) - Tower

PRO903L

PRO906L

PRO901L

PRO902L

6/72VDC

8/96VDC

2/24VDC

4/48VDC

C1*112V26AH*2

C2*112V26AH*4

C3*112V26AH*6

C4*112V17AH*16

C1*112V17AH*4

C2*112V17AH*8

C3*112V17AH*12

C8*112V26AH*16

C2*112V65AH*2

C4*112V65AH*4

C6*112V65AH*6

C8*112V100AH*8

C3*112V100AH*2

C4*112V100AH*4

C6*112V100AH*6

C24*112V65AH*24

PC96*1

C6*112V65AH*6PEC20-24*1

C12*112V65AH*12PEC15-48*1

C20*112V65AH*18PEC12-72*1

C32*112V65AH*32PEC10-96*2

POWERRATING

BACK UPTIME

1. Without cable from UPS system to battery bank.2. All batteries supply are without battery cables.

BATTERYGROUP QUANTITY

15 MINUTES

QUANTITY

30 MINUTES

QUANTITY

1 HOUR

QUANTITY

2 HOURS

QUANTITY

3 HOURS

C8*112V65AH*8PEC20-24*1

C16*112V65AH*16PEC15-48*1

C24*112V65AH*24PEC12-72*1

C20*212V65AH*40PEC10-96*3

QUANTITY

4 HOURSREMARK

DC BUS(VDC)

2. Master Series (1P/1P) - Tower

PRO802L

PRO803L

PRO801L

PRO8015L

6/72VDC

6/72VDC

3/36VDC

3/36VDC

C1*112V17AH*3

C1*112V26AH*3

C2*112V17AH*6

C3*112V26AH*6

C1*112V26AH*3

C2*112V17AH*6

C3*112V26AH*6

C3*112V17AH*12

C3*112V26AH*6

C3*112V65AH*3

C6*112V26AH*12

C6*112V65AH*6

C3*112V65AH*3

C3*112V100AH*3

C6*112V65AH*6

C6*112V100AH*6PEC12-72*1

C6*112V100AH*6PEC15-36*1

C12*112V65AH*12PEC15-36*2

C12*112V100AH*12PEC12-72*1

C20*112V65AH*18PEC12-72*1

PRO806L 20/240VDC C6*112V17AH*20

C12*112V26AH*20

C4*212V18AH*40

C20*112V26AH*40PEC24-240*1

C20*212V65AH*40PEC24-240*1

PRO810L 20/240VDC C12*112V26AH*20

C6*212V17AH*40

C20*112V65AH*20

C20*112V100AH*20PEC24-240*2

C20*212V100AH*40PEC24-240*1

POWERRATING

BACK UPTIME

1. Without cable from UPS system to battery bank.2. All batteries supply are without battery cables.

BATTERYGROUP QUANTITY

15 MINUTES

QUANTITY

30 MINUTES

QUANTITY

1 HOURS

QUANTITY

2 HOURS

QUANTITY

4 HOURS

C6*112V65AH*6PEC15-36*1

C6*112V100AH*6PEC15-36*1

C20*112V26AH*36PEC12-72*1

C12*112V100AH*12PEC12-72*1

C20*112V100AH*20PEC24-240*1

C20*312V65AH*60PEC24-240*1

QUANTITY

3 HOURSREMARK

DC BUS(VDC)

The above battery backup configuration list is only applicable to the isolation transformer UPS version.All specifications, designs and contents are subjected to changes without prior notice.

Appendix

3. Master Series (1P/1P) - 2-in-1 Rack/ Tower

PRO802RL

PRO803RL

PRO801RL

PRO8015RL

4/48VDC

6/72VDC

2/24VDC

3/36VDC

G8R*112V7AH*8

G12R*112V7AH*12

G20R*112V7AH*16

G12R*212V7AH*24

C1*112V17AH*4

C2*112V17AH*6

C2*112V17AH*8

C3*112V17AH*12

C2*112V65AH*2

C3*112V65AH*3

C4*112V65AH*4

C6*112V65AH*6

C3*112V100AH*2PEC20-24*1

C3*112V100AH*3PEC15-36*1

C4*112V100AH*4PEC15-48*1

C6*112V100AH*6PEC12-72*1

C8*112V65AH*8PEC20-24*1

C12*112V65AH*12PEC15-36*2

C16*112V65AH*16PEC15-48*2

C24*112V65AH*24 PEC12-72*2

PRO806RL 20/240VDC G20R*212V9AH*40

C12*112V26AH*20

C20*112V26AH*40PEC24-240*1

C20*112V65AH*20PEC24-240*1

C20*312V65AH*60PEC24-240*1

PRO810RL 20/240VDC G20R*412V7AH*80

C20*112V26AH*40

C20*112V100AH*20PEC24-240*1

C20*212V65AH*40PEC24-240*1

C20*412V65AH*80PEC24-240*1

POWERRATING

BACK UPTIME

BATTERYGROUP QUANTITY

15 MINUTES

QUANTITY

30 MINUTES

QUANTITY

1 HOURS

QUANTITY

2 HOURS

QUANTITY

4 HOURS

C6*112V65AH*6PEC20-24*1

C6*112V100AH*6PEC15-36*1

C12*112V65AH*12PEC15-48*1

C20*112V65AH*18PEC12-72*1

C20*212V65AH*40PEC24-240*1

C20*212V100AH*40PEC24-240*1

QUANTITY

3 HOURSDC BUS(VDC)

1. Without cable from UPS system to battery bank.2. All batteries supply are without battery cables.

REMARK

Page 97: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

95

Appendix

4. Master Series (3P/1P) - Tower

5. Master Series (3P/1P) - Rack Mount

PRO83110RL

PRO83120RL

20

20

G20R*312V9AH*60

C12*212V26AH*40

C4*212V17AH*40

C12*312V26AH*60

C20*112V65AH*20

C20*212V65AH*40PEC24-240*1

C20*112V100AH*20PEC24-240*1

C20*212V100AH*40PEC24-240*1

C20*212V100AH*40PEC24-240*1

C20*412V100AH*80PEC24-240*2

POWERRATING

BACK UPTIME

BATTERYGROUP QUANTITY

15 MINUTES

QUANTITY

30 MINUTES

QUANTITY

1 HOURS

QUANTITY

2 HOURS

QUANTITY

4 HOURS

C20*312V65AH*60PEC24-240*1

C20*612V65AH*120PEC24-240*2

QUANTITY

3 HOURSREMARK

DC BUS(VDC)

1. Without cable from UPS system to battery bank.2. All batteries supply are without battery cables.

The above battery backup configuration list is only applicable to the isolation transformer UPS version.*All specifications, designs and contents are subject to change without prior notice.

PRO83120L

PRO83110L

PRO83115L

20

20

20

C12*112V26AH*20

C6*212V17AH*40

C12*212V26AH*40

C6*212V17AH*40

C20*112V26AH*40

C12*312V26AH*60

C20*112V65AH*20

C20*112V100AH*20

C20*212V65AH*40PEC24-240*1

C20*112V100AH*20PEC24-240*1

C20*212V100AH*40PEC24-240*1

C20*212V100AH*40PEC24-240*1

C20*212V100AH*40PEC24-240*1

C20*312V100AH*60PEC24-240*1

C20*412V100AH*80PEC24-240*2

POWERRATING

BACK UPTIME

1. Without cable from UPS system to battery bank.2. All batteries supply are without battery cables.

BATTERYGROUP QUANTITY

15 MINUTES

QUANTITY

30 MINUTES

QUANTITY

1 HOURS

QUANTITY

2 HOURS

QUANTITY

4 HOURS

C20*312V65AH*60PEC24-240*1

C20*412V65AH*80PEC24-240*1

C20*612V65AH*120PEC24-240*2

QUANTITY

3 HOURSREMARK

DC BUS(VDC)

PRO83130L 20 C20*112V65AH*20

C20*112V100AH*20PEC24-240*1

C20*212V100AH*40PEC24-240*1

C20*312V100AH*60PEC24-240*1

C20*712V100AH*140PEC24-240*3

C20*512V100AH*100PEC24-240*2

PRO83320L

PRO83310L

PRO83315L

20

20

20

C12*112V26AH*20

C6*212V17AH*40

C12*212V26AH*40

C4*212V17AH*40

C20*112V26AH*40

C12*312V26AH*60

C20*112V65AH*20

C20*112V100AH*20

C20*212V65AH*40PEC24-240*1

C20*112V100AH*20PEC24-240*1

C20*212V100AH*40PEC24-240*1

C20*212V100AH*40PEC24-240*1

C20*212V100AH*40PEC24-240*1

C20*312V100AH*60PEC24-240*1

C20*412V100AH*80PEC24-240*2

POWERRATING

BACK UPTIME

1. Without cable from UPS system to battery bank.2. All batteries supply are without battery cables.

BATTERYGROUP QUANTITY

15 MINUTES

QUANTITY

30 MINUTES

QUANTITY

1 HOURS

QUANTITY

2 HOURS

QUANTITY

4 HOURS

C20*312V65AH*60PEC24-240*1

C20*412V65AH*80PEC24-240*1

C20*612V65AH*120PEC24-240*2

QUANTITY

3 HOURSDC BUS(VDC) REMARK

PRO83330L 20 C20*112V65AH*20

C20*112V100AH*20PEC24-240*1

C20*212V100AH*40PEC24-240*1

C20*312V100AH*60PEC24-240*1

C20*712V100AH*140PEC24-240*3

C20*512V100AH*100PEC24-240*2

6. Master Series (3P/3P) - Tower

Page 98: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

96

7. Power Series (3P/3P)

The above battery backup configuration list is only applicable to the isolation transformer UPS version.*All specifications, designs and contents are subject to change without prior notice.

PRO73330S

PRO73340S

PRO73315S

PRO73320S

62

62

62

62

C16*112V17AH*62

C16*112V17AH*62

C32*112V26AH*62

C16*212V17AH*124

C32*112V26AH*62

C16*212V17AH*124

C32*212V26AH*124

C16*212V17AH*124

C16*212V17AH*124

C32*212V65AH*62

C32*212V100AH*62

C32*212V26AH*124

C32*212V65AH*62

C32*212V100AH*62

C32*412V65AH*124

C32*412V65AH*124

C32*412V65AH*124

C32*412V100AH*124

C32*812V65AH*248

PRO73360S 62 C32*212V26AH*124

C32*212V65AH*62

C32*412V65AH*124

C32*412V100AH*124

C32*812V100AH*248

PRO73380S 62 C32*212V65AH*62

C32*212V100AH*62

C32*612V65AH*186

C32*812V65AH*248

C32*1012V100AH*310

POWERRATING

BACK UPTIME

1. Without cable from UPS system to battery bank.2. All batteries supply are without battery cables.

BATTERYGROUP QUANTITY

15 MINUTES

QUANTITY

30 MINUTES

QUANTITY

1 HOURS

QUANTITY

2 HOURS

C32*212V100AH*62

C32*212V100AH*62

C32*612V65AH*186

C32*412V100AH*124

C32*612V100AH*186

C32*812V100AH*248

QUANTITY

3 HOURS

QUANTITY

4 HOURSREMARK

DC BUS(VDC)

PRO733100S 62 C32*212V100AH*62

C32*412V65AH*124

C32*412V100AH*124

C32*612V100AH*186

C32*1412V100AH*434

C32*1012V100AH*310

PRO733120S 62 C32*212V100AH*62

C32*412V100AH*124

C32*812V65AH*248

C32*812V100AH*248

C32*1612V100AH*496

C32*1212V100AH*372

Appendix

1. Without cable from UPS system to battery bank.2. All batteries supply are without battery cables.

Battery ConfigurationsMODEL NO

1. Option for DC switch/protection2. Option for battery cable inter connection.For Power SeriesIncluded cables, without switch

CABINETDIMENSION(D * W * H) 100AH 65AH 38AH

Available Battery Quantity

24AH 17AH 12V7AH or12V9AH or 10Ah

CABINET WEIGHTREMARK

CIC2C3C4C6C8

C12C16C20C24C32G6

G12G18G60G8R

G12RG20R

///////////6

1218608

1220

Completed assembledCompleted assembledCompleted assembledcompleted assembledCompleted assembledCompleted assembledCompleted assembled

435*210*270450*470*320585*470*320450*470*615585*470*615780*470*615780*470*900

780*470*1190950*470*1190

1150*470*1190780*880*1190

113468

1216202432

123468

1216202432

2468

1216243240/

62

3468

1216243240/

62

51014202836/

62///

3.5kg6kg8kg

18kg22kg25kg32kg45kg45kg75kg95kg

Page 99: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting
Page 100: UNINTERRUPTIBLE POWER SUPPLY (UPS) - Prolinkdownload.prolink2u.com/br/br_UPS_Catalogue_2015_2015.04.20.pdf · CATALOGUE 2015 Revision 1.0 UNINTERRUPTIBLE POWER SUPPLY (UPS) Protecting

SINGAPOREFIDA INTERNATIONAL (S) PTE LTDBlock 16 Kallang Place#06-02, Singapore 339156Tel: (65) 6357 0668

MALAYSIAFIDA SYSTEMS (M) SDN BHDTel: (60) 3 8024 9151

INDONESIAPROLiNK INDONESIATel: (62) 21 3483 1777

Technical Support Hotline:Singapore (65) 6357 0666Malaysia (60) 3 8023 9151Indonesia (62) 21 3483 1717

Operating HoursMonday - Friday: 9.00am - 6.00pmClosed on Saturdays, Sundays & Public Holidays


Recommended