Unit no. TC07 PSV TEST CONTAINER Dimensions Length(mm)..................................... : 6057 Width(mm)............ : 2438 Height(mm)........... : 3002 Weight Tara (kg)............................ : 4600 Weight Payload ( : 9700 Weight Gross (kg : 14300 Lifting/ Transportation...................... : 20' Container with forklift channels and lifting slings. DNV 2.71. EN 12079 Certificate(s) / Serial No:................. : DNV 85168 / CS082096 / TC07 Construction year Built.................................................. : 2009 Area of use / certification Onshore/offshore............................. : Offshore Standard.......................................... : Norsok Z015, Zone 2 Z015 (type)..................................... : E Over Pressure (Yes/No).................. : Yes Type Item type.......................................... : PSV Test/Calibration container Container Type................................ : PSV container Content Content............................................ : Gasbooster : Haskel AGD75 (Pmax: 1379 Bar (20 000 PSI)) Testpump : Resato P1601151/U/V/EX (Pmax: 800 Bar (11 400 PSI)) PSVbench : Hydratron Relief valve test rig clamp w/handpump (Pmax 700 Bar) Suitable for clamping the following valves: ½” – 2” 150# 300# 600# 900# 1500# 2500# 2 ½” – 3” 150# 300# 600# 900# 1500# 4” 150# 300# 600# 900# 6” 150# 300# 600# 8” 150# 300# Connections Inlet connection............................... : Nitrogen : 1 ea. ¼” BSP Male (min 17 Bar/250 PSI) Water : 1 ea. 1” Offshore clawcoupling Air : 1 ea. 1” Offshore clawcoupling Power supply Fuse (qty)........................................ : 1 Fuse (A)........................... : 16 El.Power1........................................ : 230 V (Hz).................................. : 50/60 Additional information Equipment / Functions..................... : Tecom pressure regulating 690 Bar inlet > 413 Bar outlet Bladder accumulator Light 230V sockets Cabinet Workbench with drawers and handtools, Heater Fire extinguisher Page: 1 of 1
Transcript
Page 1: Unit no. TC-07 PSV TEST CONTAINER - IKM...PSV-bench : - Hydratron Relief valve test rig clamp w/handpump (P-max 700 Bar) Suitable for clamping the following valves: ½” – 2”

Unit no. TC­07

PSV TEST CONTAINER

DimensionsLength(mm)..................................................................: 6057 Width(mm).............................................: 2438 Height(mm).............................................: 3002Weight ­ Tara (kg)..................................................................: 4600 Weight ­ Payload (kg).............................................: 9700 Weight ­ Gross (kg).............................................: 14300Lifting/ Transportation..........................................: 20' Container with forklift channels and lifting slings. DNV 2.7­1. EN 12079Certificate(s) / Serial No:......................................: DNV 85168 / CS­08­2096 / TC­07

Construction yearBuilt..................................................................: 2009

Area of use /  certificationOnshore/offshore..................................................................: OffshoreStandard.........................................................: Norsok Z­015, Zone 2Z­015 (type)..................................................................: EOver Pressure (Yes/No)..................................................................: Yes

TypeItem type........................................................: PSV Test­/Calibration containerContainer Type..................................................................: PSV container

ContentContent..........................................................: Gasbooster : 

­ Haskel AGD­75  (P­max: 1379 Bar (20 000 PSI))

Testpump : ­ Resato P160­115­1/U/V/EX  (P­max: 800 Bar (11 400 PSI))

PSV­bench : ­ Hydratron Relief valve test rig clamp w/handpump (P­max 700 Bar)

Suitable for clamping the following valves:½” – 2” 150# 300# 600# 900# 1500# 2500#2 ½” – 3” 150# 300# 600# 900# 1500#4” 150# 300# 600# 900#6” 150# 300# 600#8” 150# 300#

ConnectionsInlet connection.................................................: Nitrogen : 1 ea. ¼” BSP Male (min 17 Bar/250 PSI)

Water :      1 ea. 1” Offshore clawcouplingAir :           1 ea. 1” Offshore clawcoupling

Power supplyFuse (qty)..................................................................: 1 Fuse (A).............................................: 16El.Power1..................................................................: 230 V (Hz).............................................: 50/60

Additional informationEquipment / Functions............................................: ­ Tecom pressure regulating 690 Bar inlet ­> 413 Bar outlet

­ Bladder accumulator­ Light­ 230V sockets ­ Cabinet­ Workbench with drawers and handtools,­ Heater­ Fire extinguisher