United States Department of the Interior BUREAU OF SAFETY AND ENVIRONMENTAL ENFORCEMENT Gulf of Mexico OCS Region 1201 Elmwood Park Boulevard New Orleans, Louisiana 70123-2394 Februarys, 2018 In Reply Refer To: GE 1035A Mr. Philip S. LeJeune LLOG Exploration Offshore, L.L.C. 1001 Ochsner Boulevard Suite 200 Covington, LA 70433 Dear Mr. LeJeune: Reference is made to your request dated January 31, 2018, received by this office on February 1, 2018, to modify Pipeline Segment No. 19349 by retrieving an associated well jumper from Subsea Well 1 to a PLEM, all in Mississippi Canyon Area Block 79. The jumper is being removed due to a recent subsea inspection. A separate application will be submitted to install a new jumper. The pipeline after well jumper removal is described as follows: Segment Size Length Service Origin Destination No. (Inches) (feet) 19349 6-7 61,214 Bulk Gas PLEM A-Delta House Mississippi Canyon Mississippi Canyon Block 79 Block 254 The proposed flowline jumper to be removed is assigned Segment No. 19923 is described as follows: Segment Size Length Service Origin Destination No. (Inches) (feet) 19923 6 86 Bulk Gas Well No SS001 PLEM Mississippi Canyon Mississippi Canyon Block 79 Block 79 Pursuant to 30 CFR 250.1000(b), your application is hereby approved. Right-of-way No. OCS-G29313 is described as follows: Pipeline Right-of-way (ROW) OCS-G 29313 is a 200-foot wide and approximately 11.59 miles (61,214 feet) long corridor associated with the 06-07-inch Pipeline Segment No. 19349 and an associated umbilical Segment No. 19439. The purpose of pipeline ROW OCS-G29313 is to maintain and operate PSN 19349 and to transport bulk gas originating from a PLEM in Block 79, through Blocks 123, 167, 211, and terminating at Platform A (Delta House) in Block 255, all in Mississippi Canyon Area.
Transcript
Page 1: United States Department of the InteriorJob #s: Delta House Jumper Recovery 203806 - Inspector charge to 203876 Pinnacle Engineering, Inc. LLOG Exploration Company Approval Status

United States Department of the Interior BUREAU OF SAFETY AND ENVIRONMENTAL ENFORCEMENT

Gulf of Mexico OCS Region 1201 Elmwood Park Boulevard

New Orleans, Louisiana 70123-2394

Februarys, 2018 In Reply Refer To: GE 1035A

Mr. Philip S. LeJeune LLOG Exploration Offshore, L.L.C. 1001 Ochsner Boulevard Suite 200

Covington, LA 70433

Dear Mr. LeJeune:

Reference is made to your request dated January 31, 2018, received by this office on February 1, 2018, to modify Pipeline Segment No. 19349 by retrieving an associated well jumper from Subsea Well 1 to a PLEM, all in Mississippi Canyon Area Block 79. The jumper is being removed due to a recent subsea inspection.

A separate application wil l be submitted to install a new jumper.

The pipeline after well jumper removal is described as follows:

Segment Size Length Service Origin Destination No. (Inches) (feet) 19349 6-7 61,214 Bulk Gas PLEM A-Delta House

Mississippi Canyon Mississippi Canyon Block 79 Block 254

The proposed flowline jumper to be removed is assigned Segment No. 19923 is described as follows:

Segment Size Length Service Origin Destination No. (Inches) (feet) 19923 6 86 Bulk Gas Well No SS001 PLEM

Mississippi Canyon Mississippi Canyon Block 79 Block 79

Pursuant to 30 CFR 250.1000(b), your application is hereby approved.

Right-of-way No. OCS-G29313 is described as follows:

Pipeline Right-of-way (ROW) OCS-G 29313 is a 200-foot wide and approximately 11.59 miles (61,214 feet) long corridor associated with the 06-07-inch Pipeline Segment No. 19349 and an associated umbilical Segment No. 19439. The purpose of pipeline ROW OCS-G29313 is to maintain and operate PSN 19349 and to transport bulk gas originating from a PLEM in Block 79, through Blocks 123, 167, 211, and terminating at Platform A (Delta House) in Block 255, all in Mississippi Canyon Area.

Page 2: United States Department of the InteriorJob #s: Delta House Jumper Recovery 203806 - Inspector charge to 203876 Pinnacle Engineering, Inc. LLOG Exploration Company Approval Status

Page 2

You shall submit written notification to this office within 30 days of the completion of the pipeline modification. This notification shall include the date the modification was completed, forensic investigation findings, and an indication that the modification was completed as approved.

Sincerelv, Digitally signed P H I L L I P b y PHILLIP SMITH

SMITH 14:45:16-Oe'OO' Date: 2018.02.05

For: Bryan A. Aoinangue Acting Regional Supervisor Regional Field Operations

Page 3: United States Department of the InteriorJob #s: Delta House Jumper Recovery 203806 - Inspector charge to 203876 Pinnacle Engineering, Inc. LLOG Exploration Company Approval Status

e x p l o r a t i o n o f f sho re

January 31, 2018

Regional Supervisor Field Operations Bureau of Safety and Environmental Enforcement 1201 Elmwood Park Boulevard New Orleans, Louisiana 70123-2394 GE 103 5A

Attention: Angie Gobert Pipeline Unit

RE: Application to Modify the Approved Rteht-of-Wav Pipeline (SN 19349) Consisting of (1) 6.625" O.D. Right-of-Way Well Jumper (Segment No. 19349), from Mississippi Canyon 79 SS001 Well to Mississippi Canyon 79 PLEM, Mississippi Canyon Block 79, OCS-G-27259, Gulf of Mexico, Offshore Louisiana

Dear Ladies and Gentleman:

Under the provisions of Title 30 CFR, Section 250 Subpart J and Title 30 CFR, Section 250 Subpart Q, LLOG Exploration Offshore, L.L.C. (LLOG) hereby submits this application in quadruplicate (original and 3 copies) for the modification of the Well Jumper portion of ROW Pipeline Segment No. 19349.

In 2016, LLOG installed one (1) 6.625" O.D. Well Jumper (Segment No. 19349) from Mississippi Canyon 79 SS001 Well Manifold to the Mississippi Canyon 79 PLEM, Mississippi Canyon Block 79, OCS-G-27259, Gulf of Mexico, Offshore Louisiana.

The proposed modification consists of the removal of the existing Well Jumper following a recent subsea inspection and structural assessment.

In support of this modification, LLOG submits the following attachments:

Proposed Removal Procedures MC 79 Well SS001 Well Jumper Details MC 79 Well Site Layout Payment Confirmation

LLOG is prepared to begin the removal as soon as possible; therefore, your earliest review and consideration will be greatly appreciated.

The installation of a new Well Jumper will be captured in a subsequent submission as part of this modification application. LLOG will be prepared to install a new Well Jumper as soon as possible.

Inquiries concerning this application should be first directed to Edie Ridgel of LLOG Exploration Offshore, L.L.C. at edier(flUlog.com. 985.801.4344. Inquires can also be directed to Mr. Glenn Mediamolle, Jr. of LLOG Exploration Offshore, L.L.C. at glennm(fl),llog.com.

I LOG I xploralion Offshoi e 10U1 Odisnei nmilevrird, Suite 10(1 Covinglon, I ouisuma 7043;) p 98h 80 I 4300

f v35 ooi /rm www Uofj.com

Page 4: United States Department of the InteriorJob #s: Delta House Jumper Recovery 203806 - Inspector charge to 203876 Pinnacle Engineering, Inc. LLOG Exploration Company Approval Status

985.801.4300 or Mr. Pete Cruz of Pinnacle Engineering Company at pclecfrzjpinnacleengr.com. 713.784.1005.

Sincerely,

LLOG Exploration Offshore, L.L.C.

Philip S. LeJeune' Treasurer Attachments & Enclosures

Page 5: United States Department of the InteriorJob #s: Delta House Jumper Recovery 203806 - Inspector charge to 203876 Pinnacle Engineering, Inc. LLOG Exploration Company Approval Status

A PINNACLE L % E N G I N E E R I N G LL0G

e x p l o r a t i o n

Document Title: MC 79 #1 Well Jumper Removal Procedure

Project Name: Delta House Jumper Removal

Pinnacle Doc. No. PRD001-203806 Pinnacle Job No. 203806

Signature Legend:

ID: MED PAC

Name: Mike Demmer Pete Cruz

Title: Project Engineer Project Manager

Job #s: Delta House Jumper Recovery

203806 - Inspector charge to 203876

Pinnacle Engineering, Inc. LLOG Exploration Company

Approval Status Description

A Issued for Review MED PAC 1/30/18 For hifonnation Only.

Rev Description Origin Check Approval Date Name Date

Delta House MC 79 #1 Well Jumper Removal Rev A Page 1 of6

Page 6: United States Department of the InteriorJob #s: Delta House Jumper Recovery 203806 - Inspector charge to 203876 Pinnacle Engineering, Inc. LLOG Exploration Company Approval Status

Document Title: Well Jumper Removal Procedure Revision No.: A Revision Date: 1/30/18

Contact Name Company Phone Offshore Construction Manager

Glenn Mediamolle glennm(S)llog.com

LLOG 985.801.4765 W 985.640.7515 M

Offshore Construction Manager

Julian Williams Julian.Williams(5)llog.com

LLOG 985.801.4767 W 985.377.3837 M

Project Manager Mike Demmer mdememer(S)pimiacleengr.com

Pinnacle 713.784.1005 W 210.394.0485 M

Offshore Inspectors TBD Pinnacle 713.784.1005 W

MC 254 "A", Delta House Control

Room

Delta House LLOG 337.761.8706

MC 254 "A", Delta House Operations Engineer & Facilities Engineer

Aron Steinocher & John Leimkuhler Aron.steinocher(S),llog.com [email protected]

LLOG 985.801.4704 W 985.789.3302 M 985.801.4748 W 985.789.2417 M

MC 254 "A", Delta House Foreman

Hilton Weaver Hilton.weaver(S)llogproduction.com

LLOG 337.761.8701

MC 254 "A", Delta House OIMs

Chuck Breaux & Joe Keller Joe.kellerraUloaproduction.com Chuck, breaux® llo gproduction.com

LLOG 337.761.8701

MC 254 'A", Delta House Operation Supervisor

Justin Castillo & Brent Langley Justin.castillo(S),llogproduction.com Brent.langley(fl)llogproduction.com

LLOG 337.761.8702

LLOG Fourchon Base TumKey Dock 164 Dudley Bemard Rd. Fourchon, LA 70357

fourchonbase(S)llog.com fourchonsup(aUlo a .com

LLOG 985.396.4110 Wl 985.396.0404 W2

Dispatcher whodatbase^llog.com LLOG 985.396.4048

ROV Vessel Dock TBD

ROV Vessel TBD

Flight Logistics lo2istics(5),llog.com LLOG

Page 2 of 6

Page 7: United States Department of the InteriorJob #s: Delta House Jumper Recovery 203806 - Inspector charge to 203876 Pinnacle Engineering, Inc. LLOG Exploration Company Approval Status

Document Title: Well Jumper Removal Procedure Revision No.: A Revision Date: 1/30/18

Section

1

2

3

4

Table of Contents

Introduction

General Information

Jumper Removal

Drawings

Page

4

4

4

6

Page 3 of 6

Page 8: United States Department of the InteriorJob #s: Delta House Jumper Recovery 203806 - Inspector charge to 203876 Pinnacle Engineering, Inc. LLOG Exploration Company Approval Status

Document Title: Well Jumper Removal Procedure Revision No.: A Revision Date: 1/30/18

1.0 Introduction

LLOG has done recent metrology at the Otis field and have determined that the MC 79 #1 jumper needs to be recovered and reworked due to changes in the initial metrology measurements.

2.0 General Information

2.1 Locations

MC 79, No. 1 (well) SN 19349

2.2 6" Jumper

6.625"OD x 0.750" WT, API 5L Gr. X65 Insulation: GSPU, 2" thick Jumper length/weight in air: 60713.61 Kips

2.3 Initial Conditions -The jumper will be flushed with MeOH to 2 times the jumper volume prior to arriving in the field

-The plet valve will be closed after the flushing operation.

3.0 Jumper Removal

3.1 Mobilize ROV vessel to MC 79 # 1. 3.2 Locate jumper and perform video survey. Call Delta House and confirm the MC

79 #1 field is powered down and well is shut in.

3.3 Inform the platform the ASD will be unplugged from the jumper.

3.4 Disconnect ASD flying leads from jumper

Notes: ASD: Unplug the ASD sensor from funnel on jumper and park sensor onto top of MC 79 tree.

3.5 ROV to setup rigging on jumper and prepare to make cuts.

3.6 ROV to use super grinder to make cuts on belly of jumper 1' from target elbows.

3.7 Recover belly section of jumper first.

Page 4 of 6

Page 9: United States Department of the InteriorJob #s: Delta House Jumper Recovery 203806 - Inspector charge to 203876 Pinnacle Engineering, Inc. LLOG Exploration Company Approval Status

Document Title: Well Jumper Removal Procedure Revision No.: A Revision Date: 1/30/18

3.8 ROV to rig up to XT-side of jumper and unlatch the KLV8 as per FMC operating procedure. Recover section to deck.

3.9 ROV to rig up to PLET-side of jumper and unlatch the KLV8 as per FMC operating procedure. Recover section to deck.

3.10 Inspect pipe with NORM Meter.

3.11 Cap pipe ends to prevent oxidation.

3.12 Install FMC short term protection caps on well and plet hubs.

3.13 Perform LiDAR metrology for MC 79 #1 replacement jumper.

3.14 Demobilize

Page 5 of 6

Page 10: United States Department of the InteriorJob #s: Delta House Jumper Recovery 203806 - Inspector charge to 203876 Pinnacle Engineering, Inc. LLOG Exploration Company Approval Status

Document Title: Well Jumper Removal Procedure Revision No.: A Revision Date: 1/30/18

4.0 Drawings

Drawing No. Rev. Title

9004 1 MC 79 Wellsite Layout - Otis

9010 0 Otis Well Jumper Details MC 79 No. 1 OPR10039959 E Operating Procedure for KLV8

Page 6 of 6

Page 11: United States Department of the InteriorJob #s: Delta House Jumper Recovery 203806 - Inspector charge to 203876 Pinnacle Engineering, Inc. LLOG Exploration Company Approval Status

s

§

I o ZD

o i O i

60-0

8'-0" (FABRICATE AT 72-0" & FIELD TRIM TO FIT)

+4-0" . i . 8 0

3'-6" (56'-0" FABRICATED) 1 , . 1 3-6

!

MATERIAL SUMMARY ITEM QTY. WT. (kips) DESCRIPTION

i -100 L.F. 6.61 PIPE, 6W x 0.750" WT, API 5L GR X65, SMLS, 12-14 MILS FBE, WITH 2.0" GSPU

2 2 3.00 ea. 6" KLV8 CLAMP CONNECTOR ASSEMBLY, 10K, COMPLETE WITH ASTM A694 (F65) TARGET ELBOW, WE PREPPED TO 6.625" x 0.750 WT, FMC TECHNOLOGIES

3 ONE 0.10 MEDIUM DEEPWATER FUNNEL AND CLAMP, CLAMP 10 6.625", AISI 316L, CLAMPON INC., (REF. DWG. 64.124.0130.08 REV. 1)

4 ONE - 12-WAY ROV CE PLUG TO ACOUSTIC SAND DETECTOR HARNESS (TO BE INSTALLED SUBSEA)

5 ONE - WOL, 6" x 1", SCH 160, ASTW A234, B15.9 6 ONE 0.46 STAB PANEL ASSEMBLY, 10,000 PSI, CLAMP IDH 10.75", WE PREP WITH

1" SCH 160 A-106 GR B PIPE, DEEPSEA TECHNOLOGIES (REF. DWG. D00027-00-200 REV. 3)

7 4 0.09 ea. TARGET ELBOW, 6" x 6", WE PREP 6.625"0 x 0.750" WT, ASTW A694 8 2 0.04 ea. ROV PANEL, KLV8, FMC, FOR 6.625" OD PIPE (TO FIT UNDER GSPU INSULATED

PIPE, REF. FMC TECHNOLOGIES DWG. DU100079316) (ROV PANEL TO BE INSTALLED AND PLUMBED BY FMC PERSONNEL AT FABRICATION YARD)

13.61 kips

ELEVATION

MUDL1NE

MC 79 WELL 88001 JUMPER SPOOL SCALE: V8"=l'-0"

6?M PIPE WITH 2" GSPU

STAB PANEL ASSY. ( ? )

PLEM

PROP. 6" WELL JUMPER (REF. DETAIL)

NfflEl CONNECTORS CLOCKED TO POSITION 2 ON BOTH ENDS.

SECTION SCALE: N.T.S.

SECTION SCALE: N.T.S.

DEC 0 9 2015

APPROVED FOR CONSTRUCTION MC 79 OTIS KEY PLAN

SCALE: r=30'-0"

NOTES 1. HYDROTEST:

THE 6̂ 8(» JUMPER SPOOL SHALL BE HYDROTESTED TO A MINIMUM OF 12,500 (-0, +200) PSI AND HELD FOR A PERIOD OF 4 HOURS. THE PRESSURE SHALL HOLD OR RISE OVER THE LAST TWO HOURS.

2. BOLT TORQUE VALUES: BOLTS (MPM TO FLANGES) SHALL BE TORQUED TO 279 ft.-lb. PER API 6A/IS01O423

THIS DRAWING IS THE PROPERTY OF AND EMBODIES CONFIDENTIAL INFORMATION OF PINNACLE ENGINEERING, INC. & LLOG EXPLORATION OFSHORE INC. THIS DRAWING AND THE INFORMATION THEREON SHALL NOT BE REPRODUCED OR DISCLOSED TO ANY OTHER PARTY OR USED FOR ANY OTHER PURPOSE OTHER THAN FOR THE BENEFIT OF AND AS AUTHORIZED BY PINNACLE ENGINEERING, INC. OR LLOG EXPLORATION OFFSHORE INC. 0 APPROVED FOR CONSTRUCTION

so. DATE DESCRIPTKW BY APPR

p PETER A. CRUZ cj

, 909(10 ftfi 4 PINNACLE

E N G I N E E R I N G

TX REGISTERED ENGR FIRM F-567

Drawn By J. GUEVARA

Dole 1-5-15

Checked By

Dale ( 7 1 - 1 5 Designed By

Date

Approved By Dole 11- *- H'

LL0G e x p l o r a t i o n

OTIS SUBSEA DEVELOPMENT MC 79 SS001 TO MC 254 DELTA HOUSE

OTIS WELL JUMPER DETAILS - MISSISSIPPI CANYON 79, No.

JOB NO. 203800 SCALE NOTED 9010 REV. Q

Page 12: United States Department of the InteriorJob #s: Delta House Jumper Recovery 203806 - Inspector charge to 203876 Pinnacle Engineering, Inc. LLOG Exploration Company Approval Status

I I

s O

5

15'

<

z o

NOIES

t. ALL BEARING AND COORDINATES SHOWN ARE UTM NORTH ZONE 16 (NAD27)

APPROVED FOR CONSTRUCTION

THIS DRAWING IS THE PROPERTY OF AND EMBODIES CONFIDENTIAL INFORMATION OF PINNACLE ENGINEERING, INC, k LLOG EXPLORATION OFFSHORE INC. THIS DRAWING AND THE INFORMATION THEREON SHALL NOT BE REPRODUCED OR DISCLOSED TO ANY OTHER PARTY OR USED FOR ANY OTHER PURPOSE OTHER THAN FOR THE BENEFIT OF AND AS AUTHORIZED BY PINNACLE ENGINEERING, INC. OR LLOG EXPLORATION OFFSHORE INC.

1 REVISED PILE LOCATION fa 0 10-23-15 APPROVED FOR CONSTRUCTION ROD PAC

NO. DATE DESCRIPTION 8Y APPR

0-^ ^ m p PETER A. CRUZ cj

„ 90900 „ P-Ji

if! PINNACLE C I N E E R I N C

TX REGISTERED ENGR FIRM F-567

Drawn By J. GUEVARA

Date 3-13-15

Checked By R. DETHLOfF

Date 10-23-15

Designed By

Date

Approved By P. CRUZ Date 10-23-15

LL©G e x p l o r a t i o n

OTIS SUBSEA DEVELOPMENT MC 79 SS001 TO MC 254 DELTA HOUSE

MISSISSIPPI CANYON 79 WELL SITE LAYOUT - OTIS

JOB NO. 203800 SCALE: NOTED 9004

Page 13: United States Department of the InteriorJob #s: Delta House Jumper Recovery 203806 - Inspector charge to 203876 Pinnacle Engineering, Inc. LLOG Exploration Company Approval Status

Pay.gov - Receipt Page 1 of 1

Pay.gov Receipt

Your payment is submitted Pay.gov Tracking ID: 267GCB6G Agency Tracking ID: 75414011075 Form Name: Pipeline ROW Modification Application Application Name: BSEE Pipeline ROW Modification Application - BY

Payment Information Payment Type: Bank account (ACH) Payment Amount: $4,169.00 Transaction Date: 01/31/2018 12:39:07 PM EST Payment Date: 02/01/2018 Region : Gulf of Mexico Contact: Carol Eaton 985-801-4300 Company Name/No: LLOG Exploration Offshore, L.L.C, 02058 Pipeline Segment No.: 19349

Account Information Account Holder Name: LLOG Exploration Offshore, L.L.C. Routing Number: 065403626 Account Number: ™ ™ ™ 8 3 2 3

Email Confirmation Receipt Confirmation Receipts have been emailed to: [email protected] [email protected]

https://www.pay.gov/public/collection/confirm/print/267GCB6G 1/31/2018