University guest house for visiting professors

SalzburgDarya Haroshka

Johannes SeeberAntoine El BitarIlgar Manafsoy

1

Final Presentation1

Page 2: University guest house for visiting FINAL

Design - requirements

Sustainable and energy efficient university building

1.Work: 10 office; meeting+presentation room; storage2.Home: 10 living units with bath, kitchen, bedroom and living room;3.Communication: foyer; exhibition room; club lounge; multipurpose hall4.Infrastructure: management; technology center; administration;Approx. 1200m²

22

Page 3: University guest house for visiting FINAL

LocationSalzburg, Austria

cold, continental climate

33

Page 4: University guest house for visiting FINAL

Design ConceptKISSPassive House components- Insulation- Triple glazed windows- Airtightness- Compactness- Mechanical ventilation with heat recoveryPV-system on the roofBore hole heat exchangerWinter garden/Thermal massNatural ventilation by nightGreen facade

44

Page 5: University guest house for visiting FINAL

LocationSalzburg, Austria

54

Page 6: University guest house for visiting FINAL

Urban Design

Location on the sideOrientationConsidering the height of surrounded buildingsView to/from castle

66

Page 7: University guest house for visiting FINAL

Ground floor

77

Page 8: University guest house for visiting FINAL

1st floor

88

Page 9: University guest house for visiting FINAL

2nd floor

99

Page 10: University guest house for visiting FINAL

roof

1010

Page 11: University guest house for visiting FINAL

section

1111

Page 12: University guest house for visiting FINAL

section

1212

Page 13: University guest house for visiting FINAL

facades

1313

Page 14: University guest house for visiting FINAL

Living units

1414

Page 15: University guest house for visiting FINAL

Living units

1515

Page 16: University guest house for visiting FINAL

Area and volume

1616

Ground floor:-574m² GFA-495m² NFA-1485m³ Volume1st floor:- 430m² GFA- 342m² NFA- 890m³ Volume2nd floor: - 430m² GFA - 342m² NFA - 890m³ Volume

TOTAL AREA:- 1430m² GFA- 1180m² NFA- 3265m³ Volume

Page 17: University guest house for visiting FINAL

Energy strategyPASSIVE STRATEGYInsulationTriple glazed windows/DoorsAirtightnessCompactnessMechanical heat recovery ventilationPassive solar useInternal heat gainsSelf shading facadeThermal massNatural Ventilation by night

ACTIVE STRATEGYPhotovoltaic for electricityBore hole heat exchangerSolar thermal collectors 1717

Page 18: University guest house for visiting FINAL

Passive strategies

1818

Passive House components- Insulation- Triple glazed windows- Airtightness- Compactness- Mechanical ventilation with heat recoveryPassive Solar useWinter garden/Thermal massNatural ventilation by nightGreen facade

Page 19: University guest house for visiting FINAL

Construction elements

1919

Outside wall, u-value 0,127 W/m²K

Page 20: University guest house for visiting FINAL

Construction elements

2020

Inside wall wintergarden, u-value 0,127 W/m²K

Page 21: University guest house for visiting FINAL

Construction elements

2121

roof, u-value 0,142 W/m²K

Page 22: University guest house for visiting FINAL

Construction elements

2222

Slap floor, u-value 0,141 W/m²K

Page 23: University guest house for visiting FINAL

Airtightness

2323

Page 24: University guest house for visiting FINAL

Winter garden

2424

Page 25: University guest house for visiting FINAL

Winter garden

2525

Page 26: University guest house for visiting FINAL

Winter garden

2626

Page 27: University guest house for visiting FINAL

Winter garden

2727

Page 28: University guest house for visiting FINAL

Winter garden

2828

Page 29: University guest house for visiting FINAL

Natural ventilation by night

2929

Page 30: University guest house for visiting FINAL

Green facade

3030

2 types of green facade - Grüne Wand - Fassadengarten

Page 31: University guest house for visiting FINAL

Green facade

3131

Page 32: University guest house for visiting FINAL

Active strategies

3232

PV-system for Mechanical Ventilation, heat pump and lightsBore hole heat exchangerSolar thermal collectors

Page 33: University guest house for visiting FINAL

PV- system on the roof

3333

-Approx. 3700 kWh for mechanical Ventilation(dark grey) = 12 PV-modules- approx. 6600 kWh for heat pump(medium grey) = 21 PV-modules- 33 free PV-modules for lighting/electricity(light grey)

Page 34: University guest house for visiting FINAL

Bore hole heat exchanger

3434

Bore hole heat exchanger with heat pump- The heat pump provides 37°C hot water which can be used for heating purposes. 10additional heating devices are placed in the showers to heat up the water to around 60°C.- In the summer the cold water is used for offices area activation for cooling- 3 drillings deliver 15kW for heating

Page 35: University guest house for visiting FINAL

Energy balance

3535

NORTHEASTSOUTHWESTHORIZONTAL

Page 36: University guest house for visiting FINAL

Energy balance

3636

Page 37: University guest house for visiting FINAL

Energy balance

3737

Page 38: University guest house for visiting FINAL

Energy balance

3838

Page 39: University guest house for visiting FINAL

3939

Page 40: University guest house for visiting FINAL

4040

Page 41: University guest house for visiting FINAL

4141

Page 42: University guest house for visiting FINAL

4242

Page 43: University guest house for visiting FINAL

4343

Page 44: University guest house for visiting FINAL

4444

Page 45: University guest house for visiting FINAL

Recommended