Unrivalled Solutions 2019Presented By Rob Sharratt Rob Sharratt
Product manager
1
ATCsupplies.ie
Unrivalled Solutions • Vision V5/EV5 Legacy IRS systems
• Meanings - Legacy, SCR, dSCR and Wideband
• SKY Q and dSCR IRS Powering
• Vision’s dSCR
• Vision dSCR Extender
• EV5-510 New Legacy Multiswitch
• Hybrid IRS• Hybrid IRS
• Amplification in an IRS
• Planning Hybrid IRS
• No Landlords Supply
• IRS TV Amplified system
• Voltage, Current and Earthing
• New Products to Support your IRS
2
Vision V5/EV5
• Legacy = SKY+HD twin feed, Freesat, Freeview
• SCR = SKY+HD, Freeview
• dSCR = SKY Q, Freesat, Freeview
• Hybrid = SKY Q, SKY+HD, Freesat and Freeview (ALL Services)
Since 2005 the majority of Legacy IRS systems have been built • Since 2005 the majority of Legacy IRS systems have been built using the VISION V5 and EV5 multiswitches
• The majority of SKY+HD receivers are connected to a VISION multiswitch (IRS)
• The majority of dSCR upgrades will involve connecting to VISION products
3
Legacy
• Legacy SKY +HD Connections
• Each output can carry only one Band/Polarity at a time
• Band/Polarity is selected by 13/18V 0/22kHz
• SKY +HD has Two tuners and requires
Tuner 2Tuner 1
• SKY +HD has Two tuners and requires two cables
• Watch TV via one tuner, record with the other
4
SCR• SCR - Single Cable Routing with Analogue
Filtering
• SCR chip provides up to 4 user bands per ‘F’ output
• Sky now allow 3 user bands 9,11,14
• The receiver selects a users band and instructs SCR chip to select the requires mux (channel) from the satellitemux (channel) from the satellite
• You can have 3 single input receivers or 1 dual and 1 single input receivers
dSCR• dSCR – digital Single Cable Routing
• Each dSCR chip provides up to 32 user bands
• The chip output is split to provide 16 user bands per ‘Subscriber’ output
• The dSCR STB selects a users band and instructs the dSCR chip to select the required Transponder (channel) the required Transponder (channel) from the satellite
6
Sky Q 2TBWith 16 User bands
selected
Sky Q 2TB 12 tuners Sky Q 1TB 8 tuners
950MHz 2150MHz
Wideband LNB (DTH)
290MHz 2340MHz
V
Up to 74 Transponders Split between V and H
UHF Ch21-60
7
290MHz 2340MHz
H
•All verticals Transponders on one cable•All horizontal Transponders on the other cable!•Terrestrial cannot be added onto these cables• This will not work with Triplexers or Quad Outlet Plates
Vision Legacy V5/EV5 • Amplifiers are not required in small-medium systems
• Low trunk power consumption per switch <100mA
• Most V5/EV5 IRS only use one PSU powered from anywhere
• System powered using Horizontal Trunk Lines 18V 2.0A [1A • System powered using Horizontal Trunk Lines 18V 2.0A [1A per Trunk]
• Very simple plug & play architecture for speed of installation
• 2A typical powers up to 18 x 32 way Multiswitches (576 Points) Plus LNB
• Example
8
80dBuV70dBuV
78dBuV70dBuV 70dBuV
60dBuV
70m
84dBuV
73dBuV
78dBuV
10m
EV5-408
EV5-210 EV5-532
EV5-532
EV5-034
9
18V
18V
70dBuV
70dBuV
•Simple 160 point IRS•No amplifiers•Single PSU•Star Wired•Up to 70m subscriber cable•1xEV5-034 Power Supply•5xEV5-532 Multiswitches•1 x EV5-408 Splitter•1 x EV5-210 Tap•665 mA current draw
EV5-532
EV5-532
EV5-532
SKY and dSCR powering
• Sky Q Gen 1 1TB and 2TB could only deliver 12V 275mA which is not enough to power a dSCR switch
• For Gen 1 SKY Q boxes a free power adapter was supplied
• 1TB box discontinued
SKY 2TB Gen 2 has the external 3.75A 12.25V PSU • SKY 2TB Gen 2 has the external 3.75A 12.25V PSU providing 400mA via LNB 1 [tested 500mA]
• All VISION dSCR ‘S’ versions multiswitches are powered by SKY Gen 2 directly Subscribers port
10
Vision dSCR• Before planning any upgrade or new installation understand
your equipment and any limitation it may have.
• Consider site specifications and mains points.
• Different Brands have very different approaches to powering and this can either complicate or simplify your installation. and this can either complicate or simplify your installation.
• When comparing brands, consider some require many PSU’s and mains points whilst others do not, saving in equipment and installation time
• Are Earth bars included?
11
Vision dSCR
• Our dSCR Range provides output choices of 2,4,6 and 8• Our dSCR Range provides output choices of 2,4,6 and 8
• Each output can provide Legacy, SCR, SCR+dSCR and dSCR
• Quick, Simple, Scalable and Flexible
• Unique range of powering options available
• Earth bars included which save you time and money
12
Vision dSCR Powering
• Direct Dc connection Powers the entire switch 1100mA - DC switch OFF• Direct Dc connection Powers the entire switch 1100mA - DC switch OFF
• DC Switch “ON” power the Trunks and localised switches
• Connection to the Subscriber port DC Switch “OFF”
– Powers the Chip set with 16 User bands
– Powers the Terrestrial Amplifier
• Total Power taken from the STB is 390mA
• Does NOT require a Mains point at the switch location
• Note The current saving in the system
13
System Levels
65-55dBµV
Recommended
14
65-55dBµV70-55dBµV
>5dB L/M & N/M>11dB MER>12dB C/N
<2*10-4 BER
dSCR & Legacy Levels
15
Vision dSCR PoweringSKY Subscriber powering for dSCR from SKY Q Gen 1
DC SWITCH OFF
TRUNK18V DC
DC ON
16
ON
Vision dSCR PoweringSKY Subscriber powering for dSCR SKY Q Gen 2
TRUNK18V DC
DC SWITCH OFF
DC ON
17
ON
Vision dSCR Parameters
• Consider Levels remember dSCR switches have satellite AGC (Automatic Gain Control) input levels between 60dBµV -95dBµV give Sat output 84dBµV, 78dBµV Legacy
• Low SAT insertion Loss <1.5~3dB, Terr +2dB
• +4~+8 dB Terrestrial gain
Input level Terrestrial aim for 70dBµV and SAT 73 dBµV• Input level Terrestrial aim for 70dBµV and SAT 73 dBµV
• System design is very flexible with 2,4,6 and 8 outputs to optimise the most cost effective configuration
• dSCR only IRS with VISION is very simply
• Lets look at a simple dSCR only IRS
18
New Vision dSCR ONLY •LNB, TV Mastamp, dSCR all powered from 1 PSU’s•Only one Mains point needed•DC control switches on dSCR set to off DEFAULT Position•Terrestrial 12V DC and Sat LNB power and Signals controlled by EV5-310
•We can see top floor only 2 , 14 points to mid floor and 10 to ground floorCurrent Consumption 3 x70mA
EV5-310 will power a 12V masthead
EV5-D2S
19
ground floor•Current Consumption 3 x70mA EV5-D8S, EV5-D42S 2 x 40mA , LNB 1 x 165, Masthead 1 x 65mA = 520mA Total
•Offering FLEXIBILITY!
masthead amplifier
EV5-D6S
EV5-D6S
EV5-D4S
EV5-D8S
EV5-310
EV5-034
• Takes 4 legacy connections and provides 4 multi outputs each can be Legacy or SCR & dSCR or dSCR
• No Loss of subscriber connections
• Compatible with all Brands
Vision dSCR EXTENDEREV5-D4E
• Compatible with all Brands
• Fast to install
• Designed to Distribute Freesat, SKY+HD/ SKY Q, Freeview, FM/DAB
• Includes EV5-034 PSU
20
Mains powered switch dSCR Upgrade
•Take any Legacy Multiswitch.•Switch Off Switch •Disconnect 4 subscriber connections.•Connect extender to these switch outputs.• Insert 4 short cables between the subscriber ports and the input on the
21
subscriber ports and the input on the EV5-D4E•Connect PSU and turn power on• you now have Legacy/SCR/dSCR available. •On ALL 4 Outputs of the EV5-D4E•Comes with PSU
Fibre dSCR Upgrade Apartment Layout
Switchblade EV-D4E Extender
22
EV-D4E ExtenderEV5-034
Fibre GTU dSCR/Legacy/Terr 10 Apartment Layout
23
10 x dSCR Points10 x Legacy Points10 Terr Points<700mA
New Legacy MultiswitchEV5-510
• Why?
• To provide the best value Legacy switch
• To simplify Hybrid installations
• Compatible with all Vision IRS products
• Quick to install
24
• Quick to install
• 5 input cascade switch
• Ideal for 5-60 dwellings Legacy or Hybrid
• Supplied with Pre-mounted Earth Bars
• Switched 75Ω Termination
• <3.5dB trunk loss, 10dB SAT/Terr Gain to subscriber outputs.
• 10 Subscriber outputs
• Very low system current 70mA from trunk (Terminated 84mA)
DC pass up to 2A on Horizontal Connections.
New Legacy MultiswitchEV5-510
• DC pass up to 2A on Horizontal Connections.
• 75Ω Terminators built in (switchable).
• Cascade up to four switches
• Indicative price £61.36.
• Lets look at a simply Legacy plan
25
New Legacy MultiswitchEV5-510
•30 apartments Twin cable•One PSU•Masthead Amplifier powered by the
26
powered by the EV5-034 2.5A PSU
• Why Hybrid?
• It offers the best value total IRS Solutions for today and the future
• Delivers everything that consumers wants or need
• VISION’s solutions are easiest and the quickest to install
Hybrid IRS
• VISION’s solutions are easiest and the quickest to install
• VISION offers the most comprehensive range of IRS products on the market
• Let’s look at a simple example
27
Hybrid IRS
EV5-310 Splitter
EV5-D8S dSCREV5-D8S dSCR
EV5-510 Legacy
• 48 Apartment Hybrid
• EV5-310 3-way splitter with masthead powering
• EV5-209A Active tap
• 48 dSCR & 50 Legacy
• EV5-510 with switch 75Ω
EV5-510 EV5-510
28
EV5-209A Active Tap 10/0dB gain
EV5-D8S dSCR
EV5-510 x 2
Legacy
EV5-510
• EV5-510 with switch 75Ωtermination
• Total Current = <1100mA
• From 1 Power Supply fed in to any EV5-510 / location
Amplifiers in an IRS• When?
• Splitting the trunk to many locations or Long Trunks
• If its just Low terrestrial signals a masthead amplifier is your best option as it has lower noise than launch amplifiersbest option as it has lower noise than launch amplifiers
• We offer 4 satellite amplified products to help you
• Lets take a look
29
Amplifiers in an IRS
EV5-100T Mains powered 4 x Sat + Terrestrial amplifier supplies 2A for multiswitch powering .
EV5-101TDC/Line Powered 4 x Sat + Terrestrial
30
4 x Sat + Terrestrial amplifier 226mA
V4-004DC/Line Powered Sat only amplifier 65mA EV5-209A
Line Powered 4 x Sat + Terrestrial amplified Tap.70mA
Planning your Hybrid IRS
• When planning a new IRS, powering is relatively easy, as you can add mains points as required but remember each point does cost circa £100
• What happens when you want to upgrade a Legacy IRS for dSCR
• With most Brands
• you quickly run out of DC power
31
• dSCR switches work on different voltages to the installed legacy product
• you often need a new PSU (mains point) per dSCR switch
• Most existing systems do not have mains power at every multiswitch location
• Adding a new mains socket is expensive circa £250 and takes time.
• VISION dSCR’s DO NOT require a PSU and in most installs no additional cabling
• Lets look at how Vision™ makes life easier
Typical 36 Apartment Legacy IRS powered from one mains point
Second Floor or Riser 3
The total system with 3X24 way multiswitches and LNB consumes less than 490mA
EV5-204
Second Floor or Riser 3
EV5-210 118071
EV5-524 118071
78dBµV
76
74
68
70
32
The AUX connection is only rated to 1A
Ground Floor or Riser 1
First Floor or Riser 2
EV5-204 118088
70
6878
Planning your Hybrid IRS
• We can see that only one PSU has been used
• To convert to Hybrid we must add 12 dSCR (8+4)points per floor
• For most brands 12 points of dSCR multiswitches would • For most brands 12 points of dSCR multiswitches would require >1.1+530mA=1.63A
• So 3 floors would require 4.89A
• Lets look at VISION’s solution
33
Full dSCR upgrade to Hybrid
•The total system with 3x24 Legacy + 3x8 + 3x4 dSCR multiswitches + LNB consumes 795mA: AUX MAX DC input to multiswitch 1A
Second Floor or Riser 3
EV5-210 118071
68
78
34
Ground Floor or Riser 1
First Floor or Riser 2
Second Floor or Riser 3
68
64
EV5-204 118088
70
Planning your Hybrid IRS• We saw that 1A is at the limit of the previous systems DC
input
• When we have a larger system without additional mains points what can we do?
• By inserting a Power Hub we can add additional PSU to the • By inserting a Power Hub we can add additional PSU to the existing mains point.
• With a Power Hub and two PSU we can increase our Trunk Current to 4A from the existing main point as per the next system
35
•In this 216 point example over 9 floors•we can add 108 dSCR points to this legacy IRS
Legacy Switches
dSCR Switches
Floors 1-7
8th Floor
36
legacy IRS•No new cabling•No additional Mains Points•From 1 power supply
Power Hub
Ground Floor
EV5-1855 Trunk Power Hub
•Trunk Power Hub designed to add or extra DC power into your IRS•Add up to 4 Amps via 2 •EV5-034 PSU’s•DC power added to Vertical and or Horizontal Trunks, Switchable•DC Power pass on terrestrial•Insertion Loss <1dB
37
•Insertion Loss <1dB• 2 may be required
18V DC Inputs / Outputs
Planning your Hybrid IRS• Designs fall into 3 types
• Star where all equipment is located in one area and all the subscriber cables run back to this location
• Trunk where all equipment is installed in the riser typically each floor and subscriber cables run back to the risereach floor and subscriber cables run back to the riser
• Tree and branch where equipment is located in number of locations spread out across the site
• Lets look at an example of a Large Legacy Tree and branch system
38
96 Apartments Tree and Branch Legacy System One mains point. How do we add dSCR?
230V
EV5-210
EV5-210
EV5-210
EV5-210 EV5-204
EV5-204
2nd
3rd
EV5-508 EV5-508
EV5-508
39
EV5-204
EV5-210
GND
EV5-204
EV5-204
12 x 8 way 60mA = 720Vision Quattro 75mA =75<900mA System current.
1st
Planning your Hybrid IRS
• The installed EV5-100 Amplifier has a 2A limit
• To carry out full dSCR conversion we need to add 12 dSCR points per floor 3 x EV5-D4S
• The updated system will comprise 24 multiswitches• The updated system will comprise 24 multiswitches
• Requiring <1.2A So no extra DC current required
40
To 3rd Floor
EV5-210
EV5-508 EV5-508
EV5-508
EV5-210 EV5-204
EV5-D4S x 3 per floor
41
To 2nd Floor
To 1st Floor
Note* dSCR’s are powered from the apartment via Gen 2 SKY Q or Gen 1 with Power inserter
12 x 8 way 60mA = 72012 x 4 Way dSCR 40mA = 320Vision Quattro 75mA =75<1.2A System current.
EV5-204
EV5-210
Planning your Hybrid IRS
• So in conclusion
• No new cabling
• Push Fit V17-005 f-male to f-male required
• No additional mains points• No additional mains points
• No Re-balancing of the system levels due AGC and Amplified Terrestrial & low through loss
• Just Plug and Go
42
Upgrading other Manufactures systems
• No Power supplies
• Minimal re-work to the existing system• Minimal re-work to the existing system
• No additional current draw from existing system
• Very low insertion loss – no need to re-balance the system
• Cost effective
43
TMM dSCR Upgrade
dSCR feeding SAT2
EV5-D8S
44
Existing system provides FM, DAB, Terr and SAT1
dSCR feeding SAT2
TMM5x16
No Landlords Supply• A significant number of smaller blocks have no landlords
supply
• Vision sold 380,000 points worth of receiver powered multiswitches in the UK
• SKY installed >180,000 points of Vision V4• SKY installed >180,000 points of Vision V4
• Without the additional costs and difficulties of providing a landlords supply
• Lets look at VISION’s solution
45
32 point V4 System
46
32 Point V4 System upgrade with dSCR
47
dSCR upgrade with Receiver power switches
48
New Build small system without Landlords supply
49
New Installation EV5-1888 + EV5-1801 - No Landlords Supply
50
51
EV5-1888 Subscriber Power Hub
• Designed for IRS system when no landlords supply is available• Suitable for up to 8 apartments• Will power LNB, Legacy and dSCR Multiswitches plus terrestrial mast head amplifiers
• EV5-1801 Subscriber Power Injector
52
• EV5-1801 Subscriber Power Injector• EV5-1888 Subscribers Power Hub• EV5-034- 2.5A power supply
No Landlords Supply• Our Landlords supply Subscriber Power Hub/ Injector works for all
Legacy V4, V5 and EV5 installations
• Enables a full dSCR upgrade
• No additional Cabling
• This works with SKY+HD, SKY Q, Freesat, Freeview• This works with SKY+HD, SKY Q, Freesat, Freeview
• Ideal for small systems 8 apartments dual cable solution.
• Providing a cost effective upgrade
• Unique Product
53
Total Hybrid
• Combination of
• Legacy Switches
• dSCR
• Additional TV points• Additional TV points
• Without additional power points
• Delivers SKY+HD, SKY Q, Freesat, Freeview
• Providing a cost effective upgrade
• Unique Products
54
EV5-310 3-Way Splitter
•3 way equal splitter •Switchable 12V for masthead powering max. 100mA•DC powering as per coloured lines•Insertion Loss <7dB SAT•<7dB Terrestrial
55
IRS TV Amplifier “Total Hybrid”EV5-110A
•Terrestrial Only Amplifier designed to fit into any VISION Legacy, dSCR and Hybrid IRS system.•Power is taken from ANY Trunk leg•LED Terrestrial Amp ON•10 Additional Terrestrial Points are
56
•10 Additional Terrestrial Points are provided•Terrestrial Gain 10dB•Trunk Loss Terrestrial <4dB/Sat1dB•Current Consumption 67/84mA•2A Trunk SAT, 0.6A Terr.•Simple “Plug and Go”
Total Hybrid 20 point Star Wired
•Small star wired system
EV5-310 EV5-110A EV5-510
EV5-D8S
EV5-D4S
EV5-D8S
EV5-034
57
•Small star wired system for 20 apartments•With 1 dSCR and Legacy to master room and TV point in bedroom•All powered by 1 IRS PSU•<700mA
EV5-510
EV5-110A
Total Hybrid Star Wired with 2 additional Bedroom points
EV5-310 EV5-110A EV5-510
EV5-D8S
EV5-D4S
EV5-D8S
EV5-034
EV5-110A
58
•Small star wired system for 20 apartments•With 1 dSCR and Legacy to master room and 2 TV points to bedrooms•All powered by 1 IRS PSU•<831mA
EV5-110A
EV5-110A
EV5-510
EV5-209A 2-way Active Tap
•2 way Active Tap•Tap outputs amplified Fixed gain•SAT 0dB Terrestrial 0dB Left side•SAT 10dB Terrestrial 6dB Right side•Low Trunk Loss <2dB
•DC powering H Lo, H Hi trunk
59
•DC powering H Lo, H Hi trunk•70mA current consumption•Power Bi-directional any input / output
•Application
Total Hybrid- Cascade
8 stories, 8 Apartments on each floordSCR, Legacy + Bedroom Point Total current Consumption 1.7A 1 Power supplyNo Launch AmplifierMasthead Amplifier
60
Total Hybrid- 60 points Star Wired
EV5-310
EV5-209A
V10-X9FTV8-001L FMV7-001 DABV23-13AKTFDUV21-SMAS
V80-80V85-IRS LC
EV5-D8S
EV5-D8SEV5-D8SEV5-110AEV5-510
EV5-D8SEV5-D4SEV5-110AEV5-510
61
•60 Apartments “Total Hybrid”•1 PSU <1.7A consumption•No Amplifier •Active Tap used
EV5-D8SEV5-110AEV5-110AEV5-510
EV5-D8SEV5-110AEV5-110AEV5-510EV5-034
EV5-D8SEV5-D8SEV5-110AEV5-510
Total Hybrid•60 Apartment Hybrid IRS with 1 x Bedroom•Mains powered amplifier powers whole system•<1.5AEV5-512
EV5-512EV5-210
EV5-210
EV5-100T
EV5-512EV5-512EV5-512
EV5-310
EV5-D8S
EV5-110A
EV5-D8S
EV5-D8S
EV5-110A EV5-110A
Total Hybrid- 30 Apartments
30 apartments over 3 floors.
Each Apartment dSCR, Legacy and additional TV
6m
EV5-310 EV5-510
EV5-D8S
EV5-D2S
EV5-034
EV5-110A
63
additional TV point for the bedroom.
*All powered by 1 IRS PSU
>1.03A consumption
12m
Total Hybrid- EV5-1855
36 apartments over 3 floors.
Each Apartment dSCR, Legacy and additional TV point/s for the bedroom.
*All powered by the EV5-1855 and IRS
64
EV5-1855 and IRS PSU EV5-0342.0A inserted on to H LinesSwitch position 2280mA per floor x 3 = 1.07mAIncluding LNB and Masthead powering
EV9 9-Wire dSCR Upgrade
Add dSCR switches to SAT ANo additional powerDue to their low insertion loss minimal effect on system
65
Total MATV
•90 TV•1 x Mastamp•1 x PSU
66
Voltage, Current
• To ensure long term reliable operation, we must consider the voltage and total current requirement of a system.
• dSCR Multiswitches consume a lot of energy and generate a lot of heat, ensure adequate ventilation
• If you are not sure measure the total consumption • If you are not sure measure the total consumption before extending the system with IRS Multimeter (V18-310)
• Never connect 2 or more PSU without DC isolating from each other
67
Why you should DC separate PSU
Top Floor
68
Bottom Floor
8 FloorsV17-018 5 x DC Blockor the TAP DC routing is switched off
Voltage, Current
• Avoid overloading the specified current of DC input’s or PSU’s
• Look for the DC control switches
• Check the voltage control switches before turning on the PSU’s
69
the PSU’s
• Short circuits or just a spark when you connect or disconnect live, may not “kill” a component, but can shorten the reliability/operational life of the system.
Voltage, Current
• Always switch power off before adding or removing components or disconnecting live cables
• Do NOT Hot Swap
• Always use Galvanic Isolators when working with more than one electrical phase or more than one building earth for safety
70
more than one electrical phase or more than one building earth for safety
Voltage, CurrentGalvanic Isolator EV5-255 blocks DC and AC on both the inner and outer conductors£15.49
The V5-033 can be used to split the DC into two legs£4.78
71
A DC block just stop the voltage on the inner conductorIt does not prevent it on the outer conductor (Braid)
DC BlockV17-018
Earthing
• Always EARTH IRS systems to the appropriate standards and recommendations
• Unearthed systems can result in a fatal electrical shock
• All Vision switches come with Earth Bond Bars
72
All Vision switches come with Earth Bond Bars
Earth-Connect™
• Unique Earthing system• Compatible with all Brands that DO NOT PROVIDE EARTH BOND BARS
73
V17-063CBag 10 V17-063A
Bag 100V17-063B
Bag 10
V17-060Bag 10
• Another first for Vision!
• First 3-in-1 multi-meter designed for TV/Sat installers.
• DC Voltage, DC Current and 22kHz activity – displayed simultaneously
Introducing the all new V18-310 IRS Multimeter
simultaneously
• Line powered
• Light weight
• Bright colour coded displays
• Lanyard for convenience
• £31.98 Indicative Price
74
V18-310 Multimeter
•Before making a measurement•Ensure DC has been properly control in systems•PSU’s are not DC connected•If more than one
75
•If more than one PSU is in system then you must measure each one
Total Hybrid- Simplicity
• “Total Hybrid” solutions from Vision
– allow you to line power any combination of Legacy, dSCR and terrestrial products to supply all of the services required by consumers in a modern IRS.
• Our IRS range: 50 products specifically designed for the UK market.• Our IRS range: 50 products specifically designed for the UK market.
• Mix and Match, Plug and Go solution
• Installs cheaper and quicker than any other brand on the market
• New Products to support your IRS
76
What’s New / Recap
77
V85-IRS LC 124684
V85-IRS LC Universal Quattro Band LNB 124684
High performance IRS system LNB designed and optimised for Hybrid, Legacy dSCR installations.
Very low current consumption <75mA @12VDC
Signal Level optimised for 78~80dBµV
Very Low Noise figure
18mm pitch between connectors
78
18mm pitch between connectors
High Cross Polar rejection
Connector Rain shield
Excellent 950MHz out of band rejection, which means the terrestrial noise floor is reduced and results in improved signal MER performance
Excellent Phase Noise rejection
Optimised with V80-80cm Vision Dish 102703
Indicative Pricing £11.49
V21-SMAS 124718
Satellite Masthead Amplifier Supply Designed for IRS system applications•Satellite input Voltage 13~18VDC•Masthead Powering 12VDC regulated 100mA•Short circuit Protection•Bi-coloured LED Green ON, Red SC Fault•Insertion Loss <1dB Satellite / Terrestrial
79
•Insertion Loss <1dB Satellite / Terrestrial•Connector pitch 18mm centres•Weatherproof Housing
• Indicative Price £8.47
V21-SMAS Application
80
EV5-310 3-Way Splitter 124225
•3 way equal splitter •Switchable 12V for masthead powering•DC powering All Lines•Insertion Loss
Terrestrial<7Sat<7dB
81
Sat<7dB
• Indicative Price £32.16
EV5-110A IRS Terrestrial Amplifier 124242
•Unique 10 output TV amplifier•10dB Gain on TV Outputs•Line Powered via any trunk•RF and DC pass on all Trunks•Low Trunk Loss <1dB, SAT, <4dB Terr•LED Amplifier ON•67 / 84mA current consumption
82
•67 / 84mA current consumption when line terminated
•Indicative Pricing £35.51
EV5-209A 2-way Active Tap 124259
•2 way Active Tap•Tap outputs amplified Fixed gain•SAT 0dB Terrestrial 0dB Left side•SAT 10dB Terrestrial 6dB Right side•Low Trunk Loss <2dB
•DC powering H Lo, H Hi trunk
83
•DC powering H Lo, H Hi trunk•70mA current consumption•Power Bi-directional any input / output•Indicative Pricing £48.15
EV5-510 5 x 10 Multiswitch 123715
•5x10 Legacy Multiswitch•Colour Coded Inputs and outputs•Earth bonding bars supplied•LTE Filtering•Line Powered•40mA drawn from Receiver•67[84 mA consumption Termination ON]
84
•67[84 mA consumption Termination ON] •Switchable terminators for all outputs•2A Power pass on all trunk connections•Subscriber outputs gain 10dB•Trunk Loss <4dB
•Indicative Pricing £61.36
EV5-1855 Trunk Power Hub 124412
Trunk Power Hub designed to inject DC power and manage your IRS current consumption•Input B, switch position 1- Power UP H,LO ~ H,Hi + Switchable 12VDC Masthead line power, DC Isolated Through line
•Input B, switch position 2- Power UP & Down H,LO ~ H,Hi + Switchable 12VDC Masthead line power
85
Masthead line power
•Input A switch position 1 Power down on V,Lo, H,Lo, V,Hi & H,Hi
•Add up to 4 Amps via 2 x EV5-034 PSU’s•DC Power pass on terrestrial•Insertion Loss <1dB
•Indicative price £30.09
18V DC Inputs
EV5-1888 Subscriber Power Hub 124429
• Designed for IRS system when no landlords supply is available• Suitable for up to 8 apartments• Will power LNB, Legacy and dSCR Multiswitches plus terrestrial mast head amplifiers
• EV5-1801 Subscriber Power Injector £4.14
86
• EV5-1801 Subscriber Power Injector £4.14• EV5-1888 Subscriber Power Hub £51.25• EV5-186- 600mA power supply £15.28
• Another first for Vision!
• First 3-in-1 multi-meter designed for TV/Sat installers.
• DC Voltage, DC Current and 22kHz activity – displayed simultaneously
Introducing the all new V18-310 IRS Multimeter
simultaneously
• Line powered
• Light weight
• Bright colour coded displays
• Lanyard for convenience
• £31.98 Indicative Price
87
Earth-Connect™
• Unique Earthing system• Compatible with all Brands that DO NOT PROVIDE EARTH BOND BARS
88
V17-063CBag 10 V17-063A
Bag 100V17-063B
Bag 10
V17-060Bag 10
Connections made easy and economicallyV17-005 f-Male to f Male Quick
Link HQ Box 100 107089£1.04 for 5
89
TMM Connecting Lead Kit 305309£4.38 per kit
£87.60 for 20 packsvs. £20.81 per box of 100
Summary• Full Product Range to support the IRS Legacy and dSCR Market
• With Reduced Installation Time• Lower Hidden Cost• No Additional mains points• Simplicity by using the building block approach
• Product Support
90
• Product Support
• Planning Service
• Training
• Competitive Pricing