+ All Categories
Home > Documents > Update on thin vs thick micro-strip detector studies

Update on thin vs thick micro-strip detector studies

Date post: 23-Mar-2016
Category:
Upload: torin
View: 35 times
Download: 0 times
Share this document with a friend
Description:
Update on thin vs thick micro-strip detector studies. G. Casse, P. Dervan, D. Forshaw, A. Greenall , I. Tsurin , S. Wonsak. CONTEXT:. - PowerPoint PPT Presentation
Popular Tags:
16
Update on thin vs thick micro-strip detector studies G. Casse, P. Dervan, D. Forshaw, A. Greenall, I. Tsurin, S. Wonsak 1 G. Casse 8th Trento Workshop, 18- 20/02/2013
Transcript
Page 1: Update on thin  vs  thick micro-strip detector studies

Update on thin vs thick micro-strip detector studies

G. Casse, P. Dervan, D. Forshaw, A. Greenall, I. Tsurin, S. Wonsak

1G. Casse 8th Trento Workshop, 18-20/02/2013

Page 2: Update on thin  vs  thick micro-strip detector studies

CONTEXT:The choice of thin silicon sensors seems to meet the requirements for lowering the material budget of the vertex detectors, providing at the same time accrued radiation hardness (at very high doses). But, how thin can they be? This certainly depends on the application and the characteristics of the detector system.Microstrip detectors are not the configuration where reduced thickness can be pushed to the lower limits. Nonetheless studying the radiation hardness properties of thin microstrip sensors gives valuable indication on the change of their properties.We show here the CC(V) measurements of 50, 100, 140 and 300 mm thick after irradiation to doses of 2E16 neq cm-2.

2G. Casse 8th Trento Workshop, 18-20/02/2013

Irradiation with reactor neutrons performed at the JSI reactor, usual thanks to V. Cindro et al., prtons Mauric Glaser et al.

Page 3: Update on thin  vs  thick micro-strip detector studies

3

Mip signal from 90Sr source

Sensors made by Micron Semiconductor on 4” wafers with thicknesses 50, 100, 140, 300 mm. 1x1 cm2, 80 mm pitch, n-in-p devices. The 50 mm thick would break (mechanically) when attached to the cooling block due to the different CTE. No measurements available after irradiation (when cooling is needed).

The method

Analogue information from the Alibava board (equipped with Beetle chip)

Irradiations performed in the JSI Ljubljana research nuclear reactor

G. Casse 8th Trento Workshop, 18-20/02/2013

Page 4: Update on thin  vs  thick micro-strip detector studies

4

Charge Collection vs Bias (CC(V)) for the 50, 100, 140, 300 mm un-irradiated sensors. As expected the signal varies linearly with thickness

Measurements before irradiation

G. Casse 8th Trento Workshop, 18-20/02/2013

Page 5: Update on thin  vs  thick micro-strip detector studies

300µm

5G. Casse 8th Trento Workshop, 18-20/02/2013

Degradation of the CC(V) with neutron fluence for the 300mm thick sensors.

Page 6: Update on thin  vs  thick micro-strip detector studies

140µm

6G. Casse 8th Trento Workshop, 18-20/02/2013

Degradation of the CC(V) with neutron fluence for the 140mm thick sensors. Likely mislabelling of one sensor, it looks like the irradiation dose of 5E15 neqcm-2 is missing.

Page 7: Update on thin  vs  thick micro-strip detector studies

100µm

7G. Casse 8th Trento Workshop, 18-20/02/2013

Degradation of the CC(V) with neutron fluence for the 100mm thick sensors. Likely mislabelling of one sensor, it looks like the irradiation dose of 5E15 neqcm-2 is missing.

Page 8: Update on thin  vs  thick micro-strip detector studies

2x1015 neq cm-2

8G. Casse 8th Trento Workshop, 18-20/02/2013

Comparison of the CC(V) after this dose for the 100, 140 and 300mm thick sensors. Collected charge similar at low voltages.

Page 9: Update on thin  vs  thick micro-strip detector studies

9G. Casse 8th Trento Workshop, 18-20/02/2013

1x1016 neq cm-2 Comparison of the CC(V) after this dose for the 100, 140 and 300mm thick sensors. Thinner sensor exhibit better collected charge at same applied bias voltage.

Page 10: Update on thin  vs  thick micro-strip detector studies

10G. Casse 8th Trento Workshop, 18-20/02/2013

2x1016 neq cm-2 Comparison of the CC(V) after this dose for the 100, 140 and 300mm thick sensors. Thinner sensor exhibit better collected charge at same applied bias voltage.

Page 11: Update on thin  vs  thick micro-strip detector studies

11G. Casse 8th Trento Workshop, 18-20/02/2013

Degradation 300µm

Page 12: Update on thin  vs  thick micro-strip detector studies

12G. Casse 8th Trento Workshop, 18-20/02/2013

CC(V)

Degradation 140µm

Page 13: Update on thin  vs  thick micro-strip detector studies

13G. Casse 8th Trento Workshop, 18-20/02/2013

CC(V)

Degradation 100µm

Page 14: Update on thin  vs  thick micro-strip detector studies

14G. Casse 8th Trento Workshop, 18-20/02/2013

CC(V)

Degradation 50µm

Page 15: Update on thin  vs  thick micro-strip detector studies

15G. Casse 8th Trento Workshop, 18-20/02/2013

1000 V

Degradation all thicknesses600 V

Page 16: Update on thin  vs  thick micro-strip detector studies

G. Casse 8th Trento Workshop, 18-20/02/201316

CONCLUSIONSThin sensors deliver higher charge collection than standard (300mm) silicon

sensors after about 2E15 neq cm-2. The thinnest 50mm sensor exhibits no degradation of CCE between 0 to 2×1016 neq cm-2. 100mm sensors also show an advantage towards the 140mm thick after the highest dose (2E15 neq cm-2).

We should study a wider range of fluences with extremely thin devices.. It is also possible that fine thickness tuning is key for experiment application (65,

75mm thick devices should equally be studied). Mechanical reasons are also important in this respect.


Recommended