UPFLOW/HORIZONTAL TWO-STAGE, VARIABLE SPEED GAS-FIRED FURNACE PUB. NO. 12-1095-06 F REEDOM 80 VS MODELS AUD060,080,100,120,140R9V © 2009 American Standard Heating & Air Conditioning
Transcript
Page 1: UPFLOW/HORIZONTAL TWO-STAGE, VARIABLE SPEED GAS … · 2009-06-16 · AIR DELIVERY — The variable speed, direct drive blower motor, has sufficient airflow for most heating and cooling

UPFLOW/HORIZONTALTWO-STAGE, VARIABLE SPEED

GAS-FIRED FURNACE

PUB. NO. 12-1095-06

FREEDOM 80VSMODELS AUD060,080,100,120,140R9V

© 2009 American Standard Heating & Air Conditioning

Page 2: UPFLOW/HORIZONTAL TWO-STAGE, VARIABLE SPEED GAS … · 2009-06-16 · AIR DELIVERY — The variable speed, direct drive blower motor, has sufficient airflow for most heating and cooling

PRODUCT DATAAmerican Standard Heating & Air Conditioning

2 DATA SUBJECT TO CHANGE WITHOUT NOTICE 12-1095-06

FREEDOM 80VS STANDARD EQUIPMENT• Common vent capability• Cleanable framed filters• Optional L.P. conversion kit• Left/right gas connection• Accessory hook-up capability• Selectable cooling fan off delay

eliminates need for BAY24X045 timedelay kit

• Enhanced cooling control

• Upflow/Horizontal andDownflow/Horizontal

• Power supply 115/1/60• 2-stage gas valve• 2-speed venter• Variable speed blower motor• Silicon Nitride hot surface igniter with

adaptive heat up• Integrated solid state control• Attractive color accents• Heavy gauge aluminized steel heat

exchanger• Multi-port In-shot burners

• Complete front service access• Alternate bottom/left/right return air• Slide out blower assembly• Hinged blower door• Perfect fit door catches• Insulated blower door• Gasketed blower door• Internal filter rack• Standard filter sizes• Two-tone color• Direct drive, variable speed motor• Integrated solid state control with

self-diagnostics

FREEDOM 80VS OPTIONAL EQUIPMENTThermostat, Mechanical 2-Stage Heating/1-Stage Cooling .......................................................................................... TAYSTAT241 [ ]Thermostat, Mechanical Heating Only With Fan Switch .............................................................................................. BAYSTAT303 [ ]Thermostat, Mechanical Heating Only ........................................................................................................................ BAYSTAT388 [ ]Thermostat, Heating/Cooling Single Stage (Mounts Horizontally) .................................................................................... AY28X092 [ ]Thermostat, Electronic Non-programmable 1-Stage Heating/1-Stage Cooling ............................................................ BAYSTAT370 [ ]Thermostat, Electronic Programmable (5-2) 1-Stage Heating/1-Stage Cooling ........................................................... BAYSTAT340 [ ]Thermostat, Heating/Cooling Single Stage (Mounts Vertically) ................................................................................... BAYSTAT305 [ ]Thermostat, Electronic Programmable 2-Stage Heating/2-Stage Cooling ................................................................. TAYSTAT302C [ ]Thermostat, Electronic Programmable 1-Stage Heating/1-Stage Cooling ................................................................. TAYSTAT300C [ ]Propane Conversion Kit ............................................................................................................................................ BAYLPKT210A [ ]Electronic Air Filter, “Perfect Fit” High Efficiency (17-1/2" Wide Gas Furnace) .......................................................... TFM175A9FR0 [ ]Electronic Air Filter, “Perfect Fit” High Efficiency (21" Wide Gas Furnace) ................................................................ TFM210A9FR0 [ ]Electronic Air Filter, “Perfect Fit” High Efficiency (24-1/2" Wide Gas Furnace) .......................................................... TFM245A9FR0 [ ]Electronic Air Filter, “Perfect Fit” Standard Efficiency (17-1/2" Wide Gas Furnace) .................................................... TFP175A9FR0 [ ]Electronic Air Filter, “Perfect Fit” Standard Efficiency (21" Wide Gas Furnace) .......................................................... TFP210A9FR0 [ ]Electronic Air Filter, “Perfect Fit” Standard Efficiency (24-1/2" Wide Gas Furnace) .................................................... TFP245A9FR0 [ ]Coil Enclosure (17-1/2" Wide Cabinets) ............................................................................................................ BAYCLE17A1722A [ ]Coil Enclosure (21" Wide Cabinets) .................................................................................................................. BAYCLE21A2130A [ ]Coil Enclosure (24-1/2" Wide Cabinets) ............................................................................................................ BAYCLE24A2430A [ ]Side Filter Rack .......................................................................................................................................................... BAYFLTR200 [ ]High Altitude Switch ................................................................................................................................................... BAYHALT249 [ ]Masonry Chimney Vent Kit ....................................................................................................................................... BAYVENT800B [ ]Filter Rack Kit 1 ..................................................................................................................................................... BAYRACK960A [ ]1 Available for models with 1800 CFM or greater which require an additional side return.

FEATURESAIR DELIVERY — The variable speed, direct drive blower motor,has sufficient airflow for most heating and cooling requirements,will switch from heating to cooling speeds on demand from roomthermostat. The blower door safety switch will prevent or termi-nate furnace operation when the blower door is removed.

STYLING — Heavy gauge steel and “wrap-around” cabinetconstruction is used in the cabinet with baked-on enamel finishfor strength and beauty. The heat exchanger section of the cabinetis completely lined with foil faced fiberglass insulation. This resultsin quiet and efficient operation due to the excellent acoustical andinsulating qualities of fiberglass. Built-in bottom pan and alternatebottom, left or right side return air connection provision.

FEATURES AND GENERAL OPERATION — The Freedom 80VS

High Efficiency Gas Furnaces employ a Hot Surface Ignition system,which eliminates the waste of a constant burning pilot. The inte-grated system control lights the main burners upon a demand forheat from the room thermostat. Complete front service access.

a. Low energy power venterb. Vent proving pressure switch.

NATURAL GAS MODELS — Central Heating furnace designs arecertified by the American Gas Association for both natural andL.P. gas. Limit setting and rating data were established and ap-proved under standard rating conditions using American NationalStandards Institute standards.

SAFE OPERATION — The Integrated System Control has solidstate devices, which continuously monitor for presence of flame,when the system is in the heating mode of operation. Dual sole-noid combination gas valve and regulator provide extra safety.

QUICK HEATING — Durable, cycle tested, heavy gauge alumi-nized steel heat exchanger quickly transfers heat to provide warmconditioned air to the structure. Low energy power vent blower,to increase efficiency and provide a positive discharge of gas fumesto the outside.

BURNERS — Multi-port In-shot burners will give years of quietand efficient service. All models can be converted to L.P. gas.

INTEGRATED SYSTEM CONTROL — Exclusively designed opera-tional program provides total control of furnace limit sensors, blowers,gas valve, flame control and includes self-diagnostics for ease ofservice. Also contains connection points for E.A.C./humidifier.

Page 3: UPFLOW/HORIZONTAL TWO-STAGE, VARIABLE SPEED GAS … · 2009-06-16 · AIR DELIVERY — The variable speed, direct drive blower motor, has sufficient airflow for most heating and cooling

12-1095-06 DATA SUBJECT TO CHANGE WITHOUT NOTICE 3

PRODUCT DATAAmerican Standard Heating & Air Conditioning

MODEL

TYPE

RATINGS 21st Stage Input BTUH

1st Stage Capacity BTUH (ICS) 32nd Stage Input BTUH

2nd Stage Capacity BTUH (ICS) 3Temp. rise (Min.-Max.) °F.

BLOWER DRIVEDiameter - Width (In.)No. UsedSpeeds (No.)CFM vs. in. w.g.Motor HPR.P.M.Volts / Ph / Hz

COMBUSTION FAN - TypeDrive - No. SpeedsMotor HP - RPMVolts / Ph / HzFLA

FILTER — Furnished?Type RecommendedHi Vel. (No.-Size-Thk.)

VENT — Size (In.)

HEAT EXCHANGERType -Fired

-UnfiredGauge (Fired)

ORIFICES — MainNat. Gas. Qty. — Drill SizeL.P. Gas Qty. — Drill Size

GAS VALVE

PILOT SAFETY DEVICEType

BURNERS — TypeNumber

POWER CONN. — V / Ph / Hz 4Ampacity (In Amps)Max. Overcurrent Protection (Amps)

PIPE CONN. SIZE (In.)

DIMENSIONSCrated (In.)

WEIGHTShipping (Lbs.) / Net (Lbs.)

AUD-R9V PRODUCT SPECIFICATIONS1

1 Central Furnace heating designs are certified by AGA and ETL.2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian

applications, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.3 Based on U.S. government standard tests.4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.

GENERAL DATA

AUD080R9V3K

Upflow / Horizontal

52,00041,60080,00064,00030 - 60

Direct10 x 7

1Variable

See Airflow Table1/2

Variable115/1/60

CentrifugalDirect - 2

1/50 - 3000115/1/60

1.0

YesHigh Velocity

1 - 17x25 - 1in.

4 Round

Alum. Steel - Type 1

20

4 — 454 — 56

Redundant - Two Stage

Hot Surface Ignition

Multi-port In-shot4

115/1/6010.515

1/2

H x W x D41-3/4 x 19-1/2 x 30-1/2

142 / 132

AUD060R9V3K

Upflow / Horizontal

39,00031,20060,00048,00030 - 60

Direct10 x 7

1Variable

See Airflow Table1/2

Variable115/1/60

CentrifugalDirect - 2

1/50 - 3000115/1/60

1.0

YesHigh Velocity

1 - 17x25 - 1in.

4 Round

Alum. Steel - Type 1

20

3 — 453 — 56

Redundant - Two Stage

Hot Surface Ignition

Multi-port In-shot3

115/1/6010.515

1/2

H x W x D41-3/4 x 19-1/2 x 30-1/2

136 / 126

AUD080R9V4K

Upflow / Horizontal

52,00041,60080,00064,00030 - 60

Direct10 x 10

1Variable

See Airflow Table3/4

Variable115/1/60

CentrifugalDirect - 2

1/50 - 3000115/1/60

1.0

YesHigh Velocity

1 - 20x25 - 1in.

4 Round

Alum. Steel - Type 1

20

4 — 454 — 56

Redundant - Two Stage

Hot Surface Ignition

Multi-port In-shot4

115/1/6012.920

1/2

H x W x D41-3/4 x 23 x 30-1/2

166 / 155

Page 4: UPFLOW/HORIZONTAL TWO-STAGE, VARIABLE SPEED GAS … · 2009-06-16 · AIR DELIVERY — The variable speed, direct drive blower motor, has sufficient airflow for most heating and cooling

PRODUCT DATAAmerican Standard Heating & Air Conditioning

4 DATA SUBJECT TO CHANGE WITHOUT NOTICE 12-1095-06

MODEL

TYPE

RATINGS 21st Stage Input BTUH

1st Stage Capacity BTUH (ICS) 32nd Stage Input BTUH

2nd Stage Capacity BTUH (ICS) 3Temp. rise (Min.-Max.) °F.

BLOWER DRIVEDiameter - Width (In.)No. UsedSpeeds (No.)CFM vs. in. w.g.Motor HPR.P.M.Volts / Ph / Hz

COMBUSTION FAN - TypeDrive - No. SpeedsMotor HP - RPMVolts / Ph / HzFLA

FILTER — Furnished?Type RecommendedHi Vel. (No.-Size-Thk.)

VENT — Size (In.)

HEAT EXCHANGERType -Fired

-UnfiredGauge (Fired)

ORIFICES — MainNat. Gas. Qty. — Drill SizeL.P. Gas Qty. — Drill Size

GAS VALVE

PILOT SAFETY DEVICEType

BURNERS — TypeNumber

POWER CONN. — V / Ph / Hz 4Ampacity (In Amps)Max. Overcurrent Protection (Amps)

PIPE CONN. SIZE (In.)

DIMENSIONSCrated (In.)

WEIGHTShipping (Lbs.) / Net (Lbs.)

AUD-R9V PRODUCT SPECIFICATIONS1

1 Central Furnace heating designs are certified by AGA and ETL.2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian

applications, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.3 Based on U.S. government standard tests.4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.

AUD120R9V5K

Upflow / Horizontal

78,00062,400120,00097,00035 - 65

Direct10 x 10

1Variable

See Airflow Table1

Variable115/1/60

CentrifugalDirect - 2

1/50 - 3000115/1/60

1.15

YesHigh Velocity

1 - 24x25 - 1in.

4 Round

Alum. Steel - Type 1

20

6 — 456 — 56

Redundant - Two Stage

Hot Surface Ignition

Multi-port In-shot6

115/1/6015.320

1/2

H x W x D41-3/4 x 26-1/2 x 30-1/2

193 / 181

AUD140R9V5K

Upflow / Horizontal

91,00072,800140,000111,00040 - 70

Direct10 x 10

1Variable

See Airflow Table1

Variable115/1/60

CentrifugalDirect - 2

1/50 - 3000115/1/60

0.95

YesHigh Velocity

1 - 24x25 - 1in.

4 Round

Alum. Steel - Type 1

20

7 — 457 — 56

Redundant - Two Stage

Hot Surface Ignition

Multi-port In-shot7

115/1/6015.320

1/2

H x W x D41-3/4 x 26-1/2 x 30-1/2

197 / 185

AUD100R9V5K

Upflow / Horizontal

65,00052,000100,00079,00035 - 65

Direct10 x 10

1Variable

See Airflow Table1

Variable115/1/60

CentrifugalDirect - 2

1/50 - 3000115/1/60

1.0

YesHigh Velocity

1 - 20x25 - 1in.

4 Round

Alum. Steel - Type 1

20

5 — 455 — 56

Redundant - Two Stage

Hot Surface Ignition

Multi-port In-shot5

115/1/6014.920

1/2

H x W x D41-3/4 x 23 x 30-1/2

166 / 155

AUD100R9V3K

Upflow / Horizontal

65,00052,000100,00080,00040 - 70

Direct10 x 7

1Variable

See Airflow Table1/2

Variable115/1/60

CentrifugalDirect - 2

1/50 - 3000115/1/60

1.0

YesHigh Velocity

1 - 17x25 - 1in.

4 Round

Alum. Steel - Type 1

20

5 — 455 — 56

Redundant - Two Stage

Hot Surface Ignition

Multi-port In-shot5

115/1/6010.815

1/2

H x W x D41-3/4 x 19-1/2 x 30-1/2

142 / 132

Page 5: UPFLOW/HORIZONTAL TWO-STAGE, VARIABLE SPEED GAS … · 2009-06-16 · AIR DELIVERY — The variable speed, direct drive blower motor, has sufficient airflow for most heating and cooling

12-1095-06 DATA SUBJECT TO CHANGE WITHOUT NOTICE 5

PRODUCT DATAAmerican Standard Heating & Air Conditioning

PERFORMANCE DATA

AUD060R9V3K FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER

OUTDOORUNIT SIZE

(TONS)

AIRFLOWSETTING

DIP SWITCH SETTING EXTERNAL STATIC PRESSURE

SW1 SW2 SW3 SW4 0.1 0.3 0.5 0.7 0.9

1.5

LOW(350 CFM/ TON) ON ON OFF ON

CFM 499 537 520 520 500WATTS 50 80 110 145 175

NORMAL(400 CFM/ TON) ON ON OFF OFF

CFM 605 610 610 597 593WATTS 60 80 120 155 180

HIGH(450 CFM/ TON) ON ON ON OFF

CFM 649 681 665 665 672WATTS 75 110 145 180 220

2

LOW(350 CFM/ TON) OFF ON OFF ON

CFM 680 722 680 696 696WATTS 80 125 150 190 225

NORMAL(400 CFM/ TON) OFF ON OFF OFF

CFM 798 804 809 823 818WATTS 105 145 170 235 280

HIGH(450 CFM/ TON) OFF ON ON OFF

CFM 884 896 924 931 931WATTS 145 180 240 280 330

2.5

LOW(350 CFM/ TON) ON OFF OFF ON

CFM 858 863 882 894 895WATTS 125 175 220 275 320

NORMAL(400 CFM/ TON) ON OFF OFF OFF

CFM 984 1017 1038 1017 1017WATTS 170 225 295 330 375

HIGH(450 CFM/ TON) ON OFF ON OFF

CFM 1125 1138 1150 1161 1161WATTS 245 315 370 435 475

3 **

LOW(350 CFM/ TON) OFF OFF OFF ON

CFM 1035 1056 1076 1076 1076WATTS 205 265 330 370 430

NORMAL **(400 CFM/ TON) OFF OFF OFF OFF

CFM 1208 1247 1268 1278 1200WATTS 300 360 440 485 490

HIGH(450 CFM/ TON) OFF OFF ON OFF

CFM 1380 1410 1402 1350 1235WATTS 440 500 550 550 525

NOTES: 1. **FACTORY SETTING. 2. CONTINUOUS FAN SETTING: HEATING OR COOLING AIRFLOW IS APPROXIMATELY 50% OF SELECTED COOLING VALUE. 3. FOR VARIABLE SPEED: LOW SPEED AIRFLOWS ARE APPROXIMATELY 30% OF LISTED VALUES. 4. LOW 350 CFM/TON IS RECOMMENDED FOR VARIABLE SPEED APPLICATION FOR COMFORT & HUMID CLIMATE SETTING: NORMAL IS 400 CFM/TON: HIGH 450 CFM/TON IS FOR DRY CLIMATE SETTING.

AUD060R9V3K FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER

AIRFLOWSETTING

DIP SWITCH SETTING EXTERNAL STATIC PRESSURE

SW7 SW8 0.1 0.3 0.5 0.7 0.9

HEATING1ST

STAGE

LOW ON ONCFM 589 604 619 604 607

TEMP. RISE 49 48 47 48 48WATTS 65 95 125 160 200

MEDIUM ** ON OFFCFM 663 694 684 681 686

TEMP. RISE 44 42 42 42 42WATTS 75 120 145 185 220

HIGH OFF OFFCFM 775 781 776 805 811

TEMP. RISE 37 37 37 36 36WATTS 105 145 180 230 270

HEATING2ND

STAGE

LOW ON ONCFM 813 818 818 837 842

TEMP. RISE 55 54 54 53 53WATTS 110 150 185 240 280

MEDIUM ** ON OFFCFM 907 919 942 958 959

TEMP. RISE 49 48 47 46 46WATTS 140 200 240 300 330

HIGH OFFCFM 1038 1066 1086 1089 1079

OFF TEMP. RISE 43 42 41 41 41WATTS 190 260 325 365 415

Notes: ** Factory setting

Page 6: UPFLOW/HORIZONTAL TWO-STAGE, VARIABLE SPEED GAS … · 2009-06-16 · AIR DELIVERY — The variable speed, direct drive blower motor, has sufficient airflow for most heating and cooling

PRODUCT DATAAmerican Standard Heating & Air Conditioning

6 DATA SUBJECT TO CHANGE WITHOUT NOTICE 12-1095-06

AUD080R9V3K FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER

OUTDOORUNIT SIZE

(TONS)

AIRFLOWSETTING

DIP SWITCH SETTING EXTERNAL STATIC PRESSURE

SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9

2.5

LOW(350 CFM/TON) OFF ON OFF ON CFM

WATTS880120

875155

860190

845225

840245

NORMAL(400 CFM/TON) OFF ON OFF OFF CFM

WATTS1020170

1000205

990240

980280

960320

HIGH(450 CFM/TON) ON ON ON OFF CFM

WATTS1110210

110260

1110320

1100350

1100385

3.0

LOW(350 CFM/TON) ON OFF OFF ON CFM

WATTS1040190

1010220

1000260

1000310

990340

NORMAL(400 CFM/TON) ON OFF OFF OFF CFM

WATTS1200250

1200320

1190370

1190415

1175450

HIGH(450 CFM/TON) ON OFF ON OFF CFM

WATTS1340355

1340425

1330475

1320530

1300570

3.5 **

LOW(350 CFM/TON) OFF OFF OFF ON CFM

WATTS1215265

1210330

1210375

1200430

1185465

NORMAL **(400 CFM/TON) OFF OFF OFF OFF CFM

WATTS1430415

1415457

1410520

1385575

1330580

HIGH(450 CFM/TON) OFF OFF ON OFF CFM

WATTS1430415

1415475

1410520

1385575

1330580

NOTES: 1. ** Factory setting 2. Continuous Fan Setting: Heating or Cooling airflow is approximately 50% of selected Cooling value. 3. For Variable Speed: low speed airflows are approximately 30% of listed values. 4. LOW 350 cfm/ton is recommended for Variable Speed application for COMFORT & HUMID CLIMATE setting; NORMAL is 400 cfm/ton; HIGH 450 cfm/ton is for DRY CLIMATE setting

AUD080R9V3K FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER

AIRFLOWSETTING

DIP SWITCH SETTING EXTERNAL STATIC PRESSURE

SW 7 SW 8 0.1 0.3 0.5 0.7 0.9

HEATING1ST

STAGE

LOW ON ONCFM

TEMP. RISEWATTS

80048100

79049135

76550155

75052

200

73053230

MEDIUM ** ON OFFCFM

TEMP. RISEWATTS

91043130

89044170

87544210

86045240

82047280

HIGH OFF OFFCFM

TEMP. RISEWATTS

106037188

102038220

101039265

101039310

100039350

HEATING2ND

STAGE

LOW ON ONCFM

TEMP. RISEWATTS

111054210

109055260

109055310

108055350

106556400

MEDIUM ** ON OFFCFM

TEMP. RISEWATTS

124548300

124048355

124048410

123048460

121549500

HIGH OFF OFFCFM

TEMP. RISEWATTS

141542410

140042470

140042530

137543580

132045590

Notes: ** Factory setting *** Above MAX temperature change value

Page 7: UPFLOW/HORIZONTAL TWO-STAGE, VARIABLE SPEED GAS … · 2009-06-16 · AIR DELIVERY — The variable speed, direct drive blower motor, has sufficient airflow for most heating and cooling

12-1095-06 DATA SUBJECT TO CHANGE WITHOUT NOTICE 7

PRODUCT DATAAmerican Standard Heating & Air Conditioning

AUD080R9V4K FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER

OUTDOORUNIT SIZE

(TONS)

AIRFLOWSETTING

DIP SWITCH SETTING EXTERNAL STATIC PRESSURE

SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9

2.5

LOW(350 CFM/TON) ON ON OFF ON CFM

WATTS86390

865130

858175

843220

831255

NORMAL(400 CFM/TON) ON ON OFF OFF CFM

WATTS995115

1005170

989210

973260

956305

HIGH(450 CFM/TON) ON ON ON OFF CFM

WATTS1101150

1112200

1111255

1107305

1101360

3.0

LOW(350 CFM/TON) OFF ON OFF ON CFM

WATTS1031125

1031175

1026215

1013270

1003320

NORMAL(400 CFM/TON) OFF ON OFF OFF CFM

WATTS1163170

1178230

1188285

1183345

1178405

HIGH(450 CFM/TON) OFF ON ON OFF CFM

WATTS1319240

1337305

1344365

1340420

1336485

3.5

LOW(350 CFM/TON) ON OFF OFF ON CFM

WATTS1182200

1206240

1211295

1211350

1211420

NORMAL(400 CFM/TON) ON OFF OFF OFF CFM

WATTS1380255

1401325

1402390

1402460

1399515

HIGH(450 CFM/TON) ON OFF ON OFF CFM

WATTS1553350

1566425

1557500

1558560

1559645

4 **

LOW(350 CFM/TON) OFF OFF OFF ON CFM

WATTS1386255

1401330

1408395

1402460

1390520

NORMAL **(400 CFM/TON) OFF OFF OFF OFF CFM

WATTS1590360

1593440

1591515

1588575

1576650

HIGH(450 CFM/TON) OFF OFF ON OFF CFM

WATTS1791360

1808615

1810615

1808775

1726800

NOTES: 1. ** Factory setting 2. Continuous Fan Setting: Heating or Cooling airflow is approximately 50% of selected Cooling value. 3. For Variable Speed: low speed airflows are approximately 30% of listed values. 4. LOW 350 cfm/ton is recommended for Variable Speed application for COMFORT & HUMID CLIMATE setting; NORMAL is 400 cfm/ton; HIGH 450 cfm/ton is for DRY CLIMATE setting

AUD080R9V4K FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER

AIRFLOWSETTING

DIP SWITCH SETTING EXTERNAL STATIC PRESSURE

SW 7 SW 8 0.1 0.3 0.5 0.7 0.9

HEATING1ST

STAGE

LOW ON ONCFM

TEMP. RISEWATTS

7824975

76251

110

75151

145

74851

185

73752225

MEDIUM ** ON OFFCFM

TEMP. RISEWATTS

8704490

86545125

86145175

84845215

83146255

HIGH OFF OFFCFM

TEMP. RISEWATTS

96240110

97440155

96340200

93841

245

91442290

HEATING2ND

STAGE

LOW ON ONCFM

TEMP. RISEWATTS

109154145

109254190

108755245

109254305

107755355

MEDIUM ** ON OFFCFM

TEMP. RISEWATTS

121149190

124348255

124348310

124448370

123548430

HIGH OFF OFFCFM

TEMP. RISEWATTS

137143255

138843325

139243395

138543455

137743515

Notes: ** Factory setting

Page 8: UPFLOW/HORIZONTAL TWO-STAGE, VARIABLE SPEED GAS … · 2009-06-16 · AIR DELIVERY — The variable speed, direct drive blower motor, has sufficient airflow for most heating and cooling

PRODUCT DATAAmerican Standard Heating & Air Conditioning

8 DATA SUBJECT TO CHANGE WITHOUT NOTICE 12-1095-06

AUD100R9V3K FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER

OUTDOORUNIT SIZE

(TONS)

AIRFLOWSETTING

DIP SWITCH SETTING EXTERNAL STATIC PRESSURE

SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9

1.5

LOW(350 CFM/TON) ON ON OFF ON CFM

WATTS51650

53675

551105

547135

530165

NORMAL(400 CFM/TON) ON ON OFF OFF CFM

WATTS58359

61592

633127

621157

618185

HIGH(450 CFM/TON) ON ON ON OFF CFM

WATTS68170

697110

701140

709180

712215

2.0

LOW(350 CFM/TON) OFF ON OFF ON CFM

WATTS68075

726120

735150

741190

745230

NORMAL(400 CFM/TON) OFF ON OFF OFF CFM

WATTS769103

819145

843190

858235

865286

HIGH(450 CFM/TON) OFF ON ON OFF CFM

WATTS882130

938190

961245

975300

970345

2.5

LOW(350 CFM/TON) ON OFF OFF ON CFM

WATTS831180

903180

928230

935275

935320

NORMAL(400 CFM/TON) ON OFF OFF OFF CFM

WATTS979167

1036240

1053295

1053345

1015368

HIGH(450 CFM/TON) ON OFF ON OFF CFM

WATTS1121245

1147310

1176383

1167442

1055396

3.0**

LOW(350 CFM/TON) OFF OFF OFF ON CFM

WATTS1061210

1081265

1095320

1101382

1032380

NORMAL **(400 CFM/TON) OFF OFF OFF OFF CFM

WATTS1185278

1223364

1251435

1205455

1101426

HIGH(450 CFM/TON) OFF OFF ON OFF CFM

WATTS1351425

1372503

1343535

1248505

1168480

NOTES: 1. ** Factory setting 2. Continuous Fan Setting: Heating or Cooling airflow is approximately 50% of selected Cooling value. 3. For Variable Speed: low speed airflows are approximately 30% of listed values. 4. LOW 350 cfm/ton is recommended for Variable Speed application for COMFORT & HUMID CLIMATE setting; NORMAL is 400 cfm/ton; HIGH 450 cfm/ton is for DRY CLIMATE setting

AUD100R9V3K FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER

AIRFLOWSETTING

DIP SWITCH SETTING EXTERNAL STATIC PRESSURE

SW 7 SW 8 0.1 0.3 0.5 0.7 0.9

HEATING1ST

STAGE

LOW ON ONCFM

TEMP. RISEWATTS

7516486

79661

132

81759175

83258218

83857263

MEDIUM ** ON OFFCFM

TEMP. RISEWATTS

86256121

92152185

95351

233

96750285

95450322

HIGH OFF OFFCFM

TEMP. RISEWATTS

95950148

100248210

103646280

103646325

100348355

HEATING2ND

STAGE

LOW ON ONCFM

TEMP. RISEWATTS

109967227

112466287

114964355

115764415

105570395

MEDIUM ** ON OFFCFM

TEMP. RISEWATTS

128658365

132156450

131356455

121561

475

111966450

HIGH OFF OFFCFM

TEMP. RISEWATTS

139953465

141952570

134755545

126559520

116364485

Notes: ** Factory setting

Page 9: UPFLOW/HORIZONTAL TWO-STAGE, VARIABLE SPEED GAS … · 2009-06-16 · AIR DELIVERY — The variable speed, direct drive blower motor, has sufficient airflow for most heating and cooling

12-1095-06 DATA SUBJECT TO CHANGE WITHOUT NOTICE 9

PRODUCT DATAAmerican Standard Heating & Air Conditioning

AUD100R9V5K FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER

AIRFLOWSETTING

DIP SWITCH SETTING EXTERNAL STATIC PRESSURE

SW 7 SW 8 0.1 0.3 0.5 0.7 0.9

HEATING1ST

STAGE

LOW ON ONCFM

TEMP. RISEWATTS

90053100

89054130

87055175

85057220

83558270

MEDIUM ** ON OFFCFM

TEMP. RISEWATTS

112543150

109044200

106046235

107045300

107045340

HIGH OFF OFFCFM

TEMP. RISEWATTS

130037220

130037290

132036365

135036430

134036490

HEATING2ND

STAGE

LOW ON ONCFM

TEMP. RISEWATTS

127059200

129058260

129058335

129058400

128058460

MEDIUM ** ON OFFCFM

TEMP. RISEWATTS

157547355

160046445

161046520

160046575

158047650

HIGH OFF OFFCFM

TEMP. RISEWATTS

187040560

189039665

186040710

187040830

173043760

Notes: ** Factory setting

AUD100R9V5K FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER

OUTDOORUNIT SIZE

(TONS)

AIRFLOWSETTING

DIP SWITCH SETTING EXTERNAL STATIC PRESSURE

SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9

3.0

LOW(350 CFM/TON) ON ON OFF ON CFM

WATTS1075135

1055185

1015220

1000265

990325

NORMAL(400 CFM/TON) ON ON OFF OFF CFM

WATTS1220185

1200240

1210295

1210350

1210410

HIGH(450 CFM/TON) ON ON ON OFF CFM

WATTS1390245

1390320

1410391

1410470

1400510

3.5

LOW(350 CFM/TON) OFF ON OFF ON CFM

WATTS1214185

1210240

1215295

1210350

1210415

NORMAL(400 CFM/TON) OFF ON OFF OFF CFM

WATTS1430310

1460355

1470430

1460500

1440555

HIGH(450 CFM/TON) ON ON ON OFF CFM

WATTS1640370

1665460

1650540

1640615

1610660

4.0

LOW(350 CFM/TON) ON OFF OFF ON CFM

WATTS1405270

1430310

1440375

1440480

1420550

NORMAL(400 CFM/TON) ON OFF OFF OFF CFM

WATTS1670395

1675490

1670550

1655630

1630700

HIGH(450 CFM/TON) ON OFF ON OFF CFM

WATTS1870540

1880635

1880730

1845800

1670640

5.0 **

LOW(350 CFM/TON) OFF OFF OFF ON CFM

WATTS1775480

1800580

1820680

1800750

1680740

NORMAL **(400 CFM/TON) OFF OFF OFF OFF CFM

WATTS2065755

2020840

1945900

1805880

1623800

HIGH(450 CFM/TON) OFF OFF ON OFF CFM

WATTS23101000

21001000

2100950

1965890

1800825

NOTES: 1. ** Factory setting 2. Continuous Fan Setting: Heating or Cooling airflow is approximately 50% of selected Cooling value. 3. For Variable Speed: low speed airflows are approximately 30% of listed values. 4. LOW 350 cfm/ton is recommended for Variable Speed application for COMFORT & HUMID CLIMATE setting; NORMAL is 400 cfm/ton; HIGH 450 cfm/ton is for DRY CLIMATE setting

Page 10: UPFLOW/HORIZONTAL TWO-STAGE, VARIABLE SPEED GAS … · 2009-06-16 · AIR DELIVERY — The variable speed, direct drive blower motor, has sufficient airflow for most heating and cooling

PRODUCT DATAAmerican Standard Heating & Air Conditioning

10 DATA SUBJECT TO CHANGE WITHOUT NOTICE 12-1095-06

AUD120R9V5K FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER

AIRFLOWSETTING

DIP SWITCH SETTING EXTERNAL STATIC PRESSURE

SW7 SW8 0.1 0.3 0.5 0.7 0.9

HEATING1ST

STAGE

LOW ON ONCFM 1007 1062 1084 1063 1063

TEMP. RISE 57 54 53 54 54WATTS 114 177 285 303 350

MEDIUM ** ON OFFCFM 1154 1211 1211 1221 1212

TEMP. RISE 50 48 48 47 48WATTS 167 230 277 344 417

HIGH OFF OFFCFM 1288 1319 1310 1349 1358

TEMP. RISE 45 44 44 43 43WATTS 208 273 330 410 460

HEATING2ND

STAGE

LOW ON ONCFM 1387 1421 1455 1488 1495

TEMP. RISE 64 63 61 60 59WATTS 250 320 400 460 540

MEDIUM ** ON OFFCFM 1589 1637 1666 1678 1541

TEMP. RISE 56 54 53 53 58WATTS 350 440 535 600 575

HIGH OFF OFFCFM 1771 1788 1804 1751 1554

TEMP. RISE 50 50 49 51 57WATTS 475 560 650 675 590

Notes: ** Factory setting

AUD120R9V5K FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER

OUTDOORUNIT SIZE

(TONS)

AIRFLOWSETTING

(See Notes)

DIP SWITCH SETTING EXTERNAL STATIC PRESSURE

SW1 SW2 SW3 SW4 0.1 0.3 0.5 0.7 0.9

3.5

LOW(350 CFM/TON) OFF ON OFF ON

CFM 1195 1243 1235 1251 1251WATTS 150 225 275 325 410

NORMAL(400 CFM/TON) OFF ON OFF OFF

CFM 1353 1403 1417 1437 1458WATTS 210 290 370 425 485

HIGH(450 CFM/TON) OFF ON ON OFF

CFM 1554 1572 1615 1634 1567WATTS 315 410 480 570 575

4

LOW(350 CFM/TON) ON OFF OFF ON

CFM 1356 1391 1399 1433 1454WATTS 200 280 370 420 510

NORMAL(400 CFM/TON) ON OFF OFF OFF

CFM 1565 1584 1633 1639 1554WATTS 320 410 475 560 575

HIGH(450 CFM/TON) ON OFF ON OFF

CFM 1766 1799 1810 1784 1590WATTS 450 550 650 685 600

5 **

LOW(350 CFM/TON) OFF OFF OFF ON

CFM 1708 1758 1759 1775 1575WATTS 420 530 585 675 585

NORMAL **(400 CFM/TON) OFF OFF OFF OFF

CFM 1994 2018 1971 1814 1618WATTS 665 775 785 725 625

HIGH(450 CFM/TON) OFF OFF ON OFF

CFM 2247 2152 2019 1861 1693WATTS 975 925 860 765 680

NOTES: 1. **FACTORY SETTING. 2. "CONTINUOUS FAN SETTING" IS THERMOSTAT FAN SWITCH "ON" AND DIP SWITCHS 5 AND 6 "ON". 3. CONTINUOUS FAN SETTING: HEATING OR COOLING AIRFLOW IS APPROXIMATELY 50% OF SELECTED COOLING VALUE. 4. FOR VARIABLE SPEED: LOW SPEED AIRFLOWS ARE APPROXIMATELY 30% OF LISTED VALUES. 5. LOW 350 CFM/TON IS RECOMMENDED FOR VARIABLE SPEED APPLICATION FOR COMFORT & HUMID CLIMATE SETTING: NORMAL IS 400 CFM/TON: HIGH 450 CFM/TON IS FOR DRY CLIMATE SETTING.

Page 11: UPFLOW/HORIZONTAL TWO-STAGE, VARIABLE SPEED GAS … · 2009-06-16 · AIR DELIVERY — The variable speed, direct drive blower motor, has sufficient airflow for most heating and cooling

12-1095-06 DATA SUBJECT TO CHANGE WITHOUT NOTICE 11

PRODUCT DATAAmerican Standard Heating & Air Conditioning

AUD140R9V5K FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER

OUTDOORUNIT SIZE

(TONS)

AIRFLOWSETTING

DIP SWITCH SETTING EXTERNAL STATIC PRESSURE

SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9

3.5

LOW(350 CFM/TON) OFF ON OFF ON CFM

WATTS1175165

1165200

1180265

1170320

1150400

NORMAL(400 CFM/TON) OFF ON OFF OFF CFM

WATTS1345225

1370285

1400360

1405440

1380490

HIGH(450 CFM/TON) ON ON ON OFF CFM

WATTS1525295

1565390

1585470

1575515

1530585

4.0

LOW(350 CFM/TON) ON OFF OFF ON CFM

WATTS1320220

1330275

1335355

1300435

1240490

NORMAL(400 CFM/TON) ON OFF OFF OFF CFM

WATTS1550310

1580400

1590475

1555540

1460610

HIGH(450 CFM/TON) ON OFF ON OFF CFM

WATTS1735430

1735510

1710600

1670675

1590710

5.0 **

LOW(350 CFM/TON) OFF OFF OFF ON CFM

WATTS1700415

1725470

1730560

1725640

1690700

NORMAL **(400 CFM/TON) OFF OFF OFF OFF CFM

WATTS1980616

1980710

1950770

1885780

1735735

HIGH(450 CFM/TON) OFF OFF ON OFF CFM

WATTS2190835

2150870

2075890

1905800

1735735

NOTES: 1. ** Factory setting 2. Continuous Fan Setting: Heating or Cooling airflow is approximately 50% of selected Cooling value. 3. For Variable Speed: low speed airflows are approximately 30% of listed values. 4. LOW 350 cfm/ton is recommended for Variable Speed application for COMFORT & HUMID CLIMATE setting; NORMAL is 400 cfm/ton; HIGH 450 cfm/ton is for DRY CLIMATE setting

AUD140R9V5K FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER

AIRFLOWSETTING

DIP SWITCH SETTING EXTERNAL STATIC PRESSURE

SW 7 SW 8 0.1 0.3 0.5 0.7 0.9

HEATING1ST

STAGE

LOW ON ONCFM

TEMP. RISEWATTS

109062130

110061

175

107063215

108062255

106063290

MEDIUM ** ON OFFCFM

TEMP. RISEWATTS

123055180

126553235

128053315

130052380

130052455

HIGH OFF OFFCFM

TEMP. RISEWATTS

138049235

140548290

142547375

143047415

145047520

HEATING2ND

STAGE

LOW ON ONCFM

TEMP. RISEWATTS

154567320

155067385

156067475

156067540

157566605

MEDIUM ** ON OFFCFM

TEMP. RISEWATTS

176059435

179058545

181058620

180058695

172560725

HIGH OFF OFFCFM

TEMP. RISEWATTS

200052615

201052715

200052790

195054820

180058775

Notes: ** Factory setting

Page 12: UPFLOW/HORIZONTAL TWO-STAGE, VARIABLE SPEED GAS … · 2009-06-16 · AIR DELIVERY — The variable speed, direct drive blower motor, has sufficient airflow for most heating and cooling

12 DATA SUBJECT TO CHANGE WITHOUT NOTICE 12-1095-06

PRODUCT DATA

SCHEMATIC DIAGRAMS FOR GAS FURNACES

AUD060,080,100,120,140R9V

LECTRICAL DATA

LEGEND

Page 13: UPFLOW/HORIZONTAL TWO-STAGE, VARIABLE SPEED GAS … · 2009-06-16 · AIR DELIVERY — The variable speed, direct drive blower motor, has sufficient airflow for most heating and cooling

12-1095-06 DATA SUBJECT TO CHANGE WITHOUT NOTICE 13

PRODUCT DATA

FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING ONLY

From Dwg. 21B341127 Rev. 0

From Dwg. 21B341126 Rev. 0

FIELD WIRING DIAGRAM FOR TWO STAGE HEATING

T

����������������O 115

��������������������������������������������������������������������������������������������������������������������������������������������������������������������V 1 PH.,

����������������������������������������������������������������������������������������������������������������������������������60 HZ., PO

��������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������WER

����������������������������������������������������������������������������������������������������������������������SUPPL������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������Y PER����������������������������������������������������������������������������������������������������������������������������������������������������LOCAL CODES������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������HUM SEE��������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������NO����������������������������������������������������������������������������������������TE 5��������������������������������������������������������������������������������������������������������EA������������������������������������������������C SEE����������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������NO����������������������������������������������������������������������������������������TE 5��������������������������������������������������������������������������������������������������������

T����������������O 115 ��������������������������������������������������������������������������������������������������������������������������������������������������������������������V 1 PH.,����������������������������������������������������������������������������������������������������������������������������������60 HZ., PO��������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������WER����������������������������������������������������������������������������������������������������������������������SUPPL������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������Y PER����������������������������������������������������������������������������������������������������������������������������������������������������LOCAL CODES������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������HUM SEE��������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������NO����������������������������������������������������������������������������������������TE 5��������������������������������������������������������������������������������������������������������EA������������������������������������������������C SEE����������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������NO����������������������������������������������������������������������������������������TE 5��������������������������������������������������������������������������������������������������������

Page 14: UPFLOW/HORIZONTAL TWO-STAGE, VARIABLE SPEED GAS … · 2009-06-16 · AIR DELIVERY — The variable speed, direct drive blower motor, has sufficient airflow for most heating and cooling

14 DATA SUBJECT TO CHANGE WITHOUT NOTICE 12-1095-06

PRODUCT DATA

FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING WITH SINGLE STAGE COOLING(OUTDOOR SECTION WITHOUT TRANSFORMER)

From Dwg. 21B341125 Rev. 1

From Dwg. 21B341124 Rev. 1

FIELD WIRING DIAGRAM FOR TWO STAGE HEATING WITH SINGLE STAGE COOLING(OUTDOOR SECTION WITHOUT TRANSFORMER)

Page 15: UPFLOW/HORIZONTAL TWO-STAGE, VARIABLE SPEED GAS … · 2009-06-16 · AIR DELIVERY — The variable speed, direct drive blower motor, has sufficient airflow for most heating and cooling

12-1095-06 DATA SUBJECT TO CHANGE WITHOUT NOTICE 15

PRODUCT DATA

FIELD WIRING DIAGRAM FOR TWO STAGE HEATING WITH TWO STAGE COOLING(OUTDOOR SECTION WITHOUT TRANSFORMER)

From Dwg. 21B341128 Rev. 0

T����������������O 115 ��������������������������������������������������������������������������������������������������������������������������������������������������������������������V 1 PH.,������������������������������������������������������������������������������������������������������������������������������������60 HZ., PO��������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������WER������������������������������������������������������������������������������������������������������������������������SUPPL������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������Y PER����������������������������������������������������������������������������������������������������������������������������������������������������LOCAL CODES����������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������HUM SEE

��������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������NO

����������������������������������������������������������������������������������������TE 5

��������������������������������������������������������������������������������������������������������EA

������������������������������������������������C SEE

����������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������NO

����������������������������������������������������������������������������������������TE 5

��������������������������������������������������������������������������������������������������������

Page 16: UPFLOW/HORIZONTAL TWO-STAGE, VARIABLE SPEED GAS … · 2009-06-16 · AIR DELIVERY — The variable speed, direct drive blower motor, has sufficient airflow for most heating and cooling

Since the manufacturer has a policy of continuous productand product data improvement, it reserves the right tochange the design and specifications without notice.

Technical Literature - Printed in U.S.A.

American StandardHeating & Air Coditioning6200 Troup HighwayTyler, TX 75707

PRODUCT DATA

AU

D-R

9V O

UTL

INE

DR

AW

ING

(ALL

DIM

EN

SIO

NS

AR

E IN

INC

HE

S)

Fro

m D

wg.

21C

3416

99 R

ev. 3

DIMENSIONS

MO

DE

LA

BC

D

*UD

060R

9V3*

**U

D08

0R9V

3**

*UD

100R

9V3*

*17

-1/2

"9-

5/8"

16-1

/4"

16"

*UD

080R

9V4*

**U

D10

0R9V

5**

21"

13-1

/16"

19-3

/4"

19-1

/2"

*UD

120R

9V5*

**U

D14

0R9V

5**

24-1

/2"

15-5

/16"

23-1

/4"

23"

* -

Firs

t Let

ter

May

Be

"A"

or "

T"

*

* -

Suf

fix L

ette

rs M

ay B

e "K

" (0

Thr

ough

9)


Recommended