+ All Categories
Home > Documents > UPnP Working Group Home Control & Security 29 October 2002 - Status - Markus A. Wischy Corporate...

UPnP Working Group Home Control & Security 29 October 2002 - Status - Markus A. Wischy Corporate...

Date post: 31-Dec-2015
Category:
Upload: maximilian-anthony
View: 213 times
Download: 0 times
Share this document with a friend
Popular Tags:
12
UPnP Working Group Home Control & Security 29 October 2002 - Status - Markus A. Wischy Corporate Technology Siemens AG
Transcript
Page 1: UPnP Working Group Home Control & Security 29 October 2002 - Status - Markus A. Wischy Corporate Technology Siemens AG.

UPnP Working Group Home Control & Security

29 October 2002- Status -

Markus A. Wischy

Corporate Technology

Siemens AG

Page 2: UPnP Working Group Home Control & Security 29 October 2002 - Status - Markus A. Wischy Corporate Technology Siemens AG.

Home Automation & Security DCP definitions finalized The Home Automation & Security

working committee has defined DCPs for these application areas: Lighting HVAC Digital (Security) Camera Blinds / Shutter / Motor Control Power System Security System

Page 3: UPnP Working Group Home Control & Security 29 October 2002 - Status - Markus A. Wischy Corporate Technology Siemens AG.

Generic Services Template design complete

ExtendedDeviceInformation HouseStatus

Useful Services for any UPnP device

Call for sample implementers

Page 4: UPnP Working Group Home Control & Security 29 October 2002 - Status - Markus A. Wischy Corporate Technology Siemens AG.

Lighting Template design complete Sample Implementers:

Siemens, EIBA, Echelon, Lutron Sample testing pending TC approval 45 day review Comments resolution SC approval

Device(s)Device(s) - BinaryLight - DimmableLight

Service(s)Service(s) - SwitchPower - Dimming

Page 5: UPnP Working Group Home Control & Security 29 October 2002 - Status - Markus A. Wischy Corporate Technology Siemens AG.

Digital (Security) Camera

Template design complete Sample implementers:

Axis, D-Link, Logitech, Panasonic Plugfest --> 31 Oct 2002 Sample testing --> by 15 Nov 2002 TC approval --> by 15 Dec 2002 45 day review 16 Dec ‘02 - 30 Jan

‘03 Comments resolution --> by Mar 2003 SC approval

Device(s)Device(s) - DigitalSecurityCamera

Service(s)Service(s) - DigitalSecurityCameraSettings - DigitalSecurityCameraStillImage - DigitalSecurityCameraMotionImage

Page 6: UPnP Working Group Home Control & Security 29 October 2002 - Status - Markus A. Wischy Corporate Technology Siemens AG.

HVAC Template design complete Sample Implementers:

Siemens, SBT, White-Rodgers Sample testing SBT; others

pending TC approval 45 day review Comments resolution SC approvalDevice(s)Device(s)

- HVAC_System - HVAC_ZoneThermostat

Service(s)Service(s) - HVAC_UserOperatingMode - HVAC_FanOperatingMode - FanSpeed - TemperatureSensor - HVAC_SetpointSchedule - ControlValve - TemperatureSetpoint

Page 7: UPnP Working Group Home Control & Security 29 October 2002 - Status - Markus A. Wischy Corporate Technology Siemens AG.

Shutter / Blind / Motor Control Template design complete Sample Implementers:

Somfy, Siemens

Call for third sample implementer.

Device(s)Device(s) - SolarProtectionBlind

Service(s)Service(s) - TwoWayMotionMotor

Page 8: UPnP Working Group Home Control & Security 29 October 2002 - Status - Markus A. Wischy Corporate Technology Siemens AG.

Power System Template design complete Sample Implementers:

APC, MGE UPS, Powerware, Siemens Sample implementation is pending because

UPnP Security services are required for Power System devices and services (e.g. PowerMeter)

Device(s)Device(s) - PowerSystem - PowerSource - PowerSink - PowerConverter - PowerStorage - UPS Device

Service(s)Service(s) - PowerMeter - ProgrammableTimer - GenericPowerStorage - GenericPowerConverter - BasicPowerSummary - PredictivePowerSummary - PowerFlow - PowerSocket - Battery - Charger

Page 9: UPnP Working Group Home Control & Security 29 October 2002 - Status - Markus A. Wischy Corporate Technology Siemens AG.

Security and Access Control System Template design complete Sample Implementers:

KABA Benzing, Metrolink, Visonik Sample implementation is pending because

UPnP Security services are required.

Device(s)Device(s) - SecurityAccessControl

Service(s)Service(s) - Relay - EventLog - Display - Partition - BooleanSensor - PINPad - Reader

Page 10: UPnP Working Group Home Control & Security 29 October 2002 - Status - Markus A. Wischy Corporate Technology Siemens AG.

Doorbell scenario

Push event:

„Somebody is at your door“

Bell(SwitchPower)

Push button(BooleanSensor)

UPnP Door(TwoWayMotionMotor)

GPRS/WLAN

Siemens SX 45(Control Point) UPnP Security Camera

(CameraStillImage)

Home Server(UPnP Control Point / Entrance Device)

GPRS/WLAN

Action

„Open the door“

UPnP event

GET image

UPnP action:Open

Page 11: UPnP Working Group Home Control & Security 29 October 2002 - Status - Markus A. Wischy Corporate Technology Siemens AG.

Demo

Action!

Page 12: UPnP Working Group Home Control & Security 29 October 2002 - Status - Markus A. Wischy Corporate Technology Siemens AG.

For the interconnected lifestyle


Recommended