+ All Categories
Home > Documents > Upvc Wall Panal

Upvc Wall Panal

Date post: 07-Apr-2018
Category:
Upload: kalpana-jeyaraj
View: 223 times
Download: 0 times
Share this document with a friend

of 13

Transcript
  • 8/4/2019 Upvc Wall Panal

    1/13

    Animal Biosafety Level 3 Checklist

    The following items fall under the category of secondary barriers pertaining to the laboratory facility

    design.

    Item

    Issue

    Y/N

    Comment

    1

    Signage: biohazard sign, agents used, name, and

    telephone number.

    2

    Lab separated from building traffic.

    3

    Self-closing and self-locking door at entry.

    4

    Movement of supplies or wastes can be through aseparate double-door access or autoclave.

    5

    Double-door entry (inward opening) into the animal

    room that includes a change room and shower(s).

    6

    A hands-free or automatically operated hand wash-ing sink is provided in each animal room near the

    exit door.

  • 8/4/2019 Upvc Wall Panal

    2/13

    7

    Internal building services such as light fixtures, duct-

    work, and piping are arranged to minimize horizon-

    tal surfaces.

    8

    Interior of surfaces of walls, floors, and ceilings

    where BSL-3 agents are handled are constructed for

    easy cleaning and decontamination.Walls, ceilings,

    and floors should be smooth, impermeable to liquidsand resistant to chemicals. Seams, if present should

    be sealed.

    9

    Windows are not recommended. Any windows mustbe resistant to breakage and must be sealed.

    10

    Ventilation should be provided in accordance with

    criteria from the Guide for the Care and Use of

    Laboratory Animals.

    11

    A ducted ventilation system is provided to create

    directional airflow from clean areas toward contami-nated areas.

    12

    Exhaust air is not re-circulated to any other area of

    the building.

    13

  • 8/4/2019 Upvc Wall Panal

    3/13

    The outside exhaust must be dispersed away from

    occupied areas and air intakes or must be HEPA-fil-

    tered.

    14Lab personnel must verify direction of airflow. Providevisual monitoring device at animal room entry.

    15

    Consideration should be given to installing an HVAC

    control system to prevent sustained positive pressur-ization of the animal spaces.

    16

    Audible alarms to notify personnel of HVAC system

    failure.

    17

    Biological safety cabinets, when connected to the

    exhaust system must be done in a manner that avoids

    interference with the air balance of the cabinets orbuilding exhaust system.

    18

    Biological safety cabinets are located away from

    doors, room supply louvers, and from heavily-traveled

    areas.

    19

    Vacuum lines are to be protected with disinfectant

    traps and HEPA filters.

  • 8/4/2019 Upvc Wall Panal

    4/13

    20

    Eyewash station available inside the laboratory?

    21

    Illumination adequate for all activities?

    22

    A method for decontaminating all laboratory wastesis available in the facility.

  • 8/4/2019 Upvc Wall Panal

    5/13

    http://www.nicomac.com/contact.html

    Cleanroom Partition Walls

    Nicomac pharmaceutical cleanroomwalls are a composite construction of two skins of high pressure plastic laminate over an aluminum

    framework with a sealed and insulated interior. Standard modular clean room panel dimensions are1250 mm (4') wide with an overall length ranging from 3 to 4,2 mt (10 to 14). Standard panels havean overall thickness of 45 mm (1 3/4"). The assembly is self-supporting. Additional wall heights can be

    achieved by using a stacking technique. The self-supporting, insulated walls are assembled with an

    interior aluminum framework. The panel seams are sealed by silicone with a perfectly flush finishing.

    (UPVC welded seams are also available). Insulation materials are sandwiched between the two skinlayers and sealed from the exterior by the aluminum framework. There is a selection list of materials

    for insulation and wall skins according different needs in cleanroom construction. The Nicomac unique

    standard wall skin is an anti-scratch high-pressure laminate (impregnated with a special phenolic resinto be fire resistant). The high-pressure laminate can be easily milled to allow flush mounting of all

    covings and accessories and guarantees compliance with cGMP rules for room cleaning. The wall

    system is flexible thus allowing easy cleanroom installation and accepts changes to design in the fieldand can be reconfigured for use in other locations.Upvc coated and metal powder coated metal panels

    are also available.

    http://www.nicomac.com/clean_room_partition_upvc.htmlhttp://www.nicomac.com/clean_room_partition_upvc.htmlhttp://www.nicomac.com/clean_room_partition_upvc.htmlhttp://www.nicomac.com/clean_room_partition_upvc.htmlhttp://www.nicomac.com/clean_room_partition_upvc.htmlhttp://www.nicomac.com/clean_room_partition_upvc.htmlhttp://www.nicomac.com/clean_room_partition_upvc.html
  • 8/4/2019 Upvc Wall Panal

    6/13

    With Nicomac wall system you can achieve:

    CGMP certified cleanroom design

    Full compatibility with chemicals used for cleaning and sanitizing

    Installed in all major pharmaceutical companies

    Easy clean room installation

    State-of-the-art cleanroom technology Flush surfaces everywhere!

    Antiscratch materials

    Easy to modify during wall installation

    Wall system suitable for ISO 5 (Class 100) to ISO 8 (Class 100,000) cleanrooms

    Cleanroom Doors

  • 8/4/2019 Upvc Wall Panal

    7/13

    Nicomac cleanroom doors can be configured assingle/double swing-out or as horizontal sliding either manual, automatic or semiautomatic. Nicomac

    Pharmaceutical door panels are assembled with the same panels of the wall system. Swing out doors

    are designed to fit flush with both sides of the wall panel system and are supplied in several

    dimensions. The internal framework is constructed of welded extruded aluminum profiles. Theexternal frames are manufactured with rounded anodized or epoxy coated aluminum profiles with air

    tight dual gaskets. All fasteners for the hinges and latches can be recessed into the door frame.

    Standard hinges allow doors to swing 180 degrees from full open to full closed position.

    Nicomac pharmaceutical clean room doors are available also with interfacing profile for a flush and

    easy installation on existing walls.

    Fully flush surfaces with wall system

    A large variety of swing out pharmaceutical doors

    Manual, semiautomatic and fully automatic sliding doors

    Door hardware by world market leading manufacturers

    Custom dimensions available

    PLC controlled interlocking system for GMP compliance.

    Heavy-duty structure for high durability

    Full compatibility with chemicals used for cleaning and sanitizing

  • 8/4/2019 Upvc Wall Panal

    8/13

    Clean Room Ceilings Walk On & Standard

    Suspended False Ceilings

    Nicomac T grid type

    Our unique T-grid walks on clean room suspended ceilings consist of a load-bearing structure made of

    aluminum suitable to support ceiling panels, lights and filter units. The T-grid is supported by threadedtension bars with adjustable turnbuckles that are fastened to the overhead support at 4 intervals. There

    is a selection of two standard panel sizes: 2' x 2' (605 x 605 mm) or 2' x 4' (605 x 1210 mm).

    Tiles for our clean room ceilings can be designed to be flush to the grid. Depending on the type of tile

    used the entire ceiling system can be certified as walk on (single load of 160 Kg (352 Lb) in a square

    meter of false ceiling and situated in the most unfavorable static position).

    Our pharmaceutical T grid false ceilings can be used when ceiling maintenance is provided for the

    room and walk on ceilings are not necessary. Dedicated less expensive pharmaceutical grade tiles areused in this case.

    (Click image to enlarge) (Click image to enlarge) (Click image to enlarge) (Click image to enlarge)

    Advantages of Nicomac unique walk on T grid system

    T grid system requires not cut outs for filters and light fixtures

    Flexibility while positioning filters and light fixtures

    Flush to the grid walk on system!1250 mm x 3000 mm (4' x 10') false ceiling

    This is a hermetic false suspended ceiling. Flexible and easy to assemble, it can be installed before orafter wall location. This kind of false ceiling is made by means of polystyrene or polyurethane panels

    sandwiched between two layers of aluminum plates. Both sides are pre-painted with epoxy powder

    coating. All sides are closed by aluminum frame. The result is a perfectly smooth and coplanar surfacethat is very easy to clean. The bearing aluminum profile is housed by clicking-in between panels.

    There is a threaded tension bar, with an adjustment ring, to be fastened to the existing ceiling.

  • 8/4/2019 Upvc Wall Panal

    9/13

    Filter, light and other filter accessories can be accessed from the top of the clean room ceiling. Holes

    for filters, light and utilities are prepared at our site with HI tech Numeric Control Pantograph.

    Cleanroom Windows

    All window units for the Nicomacmodular cleanroom system are double glazed, and fit flush with both surfaces of the wall panel system

    (45mm). Each unit is constructed of two panels of 3+3 mm double layered and laminated safety glass.

    Each panel includes a layer of PVB (polyvinyl butyral) film laminated between two layers of glass. The

    two panels sit within a structured framework, and air fills the space between the two panels.

    The window system is especially designed for the cleaning needs of the pharmaceutical cleanroom. It iscompletely silicone sealed, and includes a micro-perforation profile with an integral silica gel moisture

    absorption system, designed to eliminate fogging. Rounded corners add to the strength of the

    cleanroom window unit and enhance their appearance.

    Tempered glass (6mm) in place of the laminated glass is available upon request.

    Nicomac windows can be installed in existing clean rooms.

    Fully flush to the wall

    Unique rounded corners available

    Double glass and safety film

    Full glass panels available

  • 8/4/2019 Upvc Wall Panal

    10/13

    Bioasset Technologies Private Limited, Maharastra

    Contact Person : Mrs. Manjiri Ashtekar(Director)

    Designation: Director

    Address : 213, Shree Siddhi Manora, Agashi Road, Virar (W)

    Thane, Maharashtra - 401 303 (India) Tel. : +91-250-3058380 / 32987345

    E-mail :[email protected]

    mailto:[email protected]?subject=Enquiry%20from%20Maharashtra%20Industries%20Directory.mailto:[email protected]?subject=Enquiry%20from%20Maharashtra%20Industries%20Directory.mailto:[email protected]?subject=Enquiry%20from%20Maharashtra%20Industries%20Directory.
  • 8/4/2019 Upvc Wall Panal

    11/13

    Contact

    Address:Corporate Headquarters

    Dyna House

    98/A5, Hadapsar Industrial

    Estate,Behind Kirloskar Pneumatic,

    Pune - 411 013. INDIA.

    Phn : +91 - 20 - 26872772 / 26873705 / 26811288 /

    26814076Fax : +91 - 020- 26877955

    Product Help and SupportProduct support options and contact information.

    Mr. Ramesh Yemul, Director - Research & Projects

    Mobile: +91 9822192665

    [email protected]

    Sales and Marketing

    Get more information about purchasing Dyna Filter products. [email protected]

    Corporate Information

    Corporate contact information and communication.

    [email protected]

    Clean Room Contains

    Partition wall Panels

    1. Plane panels

    2. view panel3. Inbuilt Riser Panel

    Ceiling Panels

    Clean Room Doors

    Coving

    Risers

    Hepa filter housing

    Hepa filters Clean Room Equipment

    1A) Partition Wall Panels-(plane)

    MOC -1. P.C.G.I. ( Pre Coated Galvanize Iron)

    2. Aluminum

    3. Stainless Steel (304)

    Construction- Factory Fabricated Double Skin Sandwich panels.

    mailto:[email protected]:[email protected]:[email protected]:[email protected]:[email protected]:[email protected]
  • 8/4/2019 Upvc Wall Panal

    12/13

    Insulation - Polyurethane Insulation

    Density - 40 kg/ m3

    Installation - Male Female attachment.

    Size -

    1. 1200x2400 , 1200x3000 , 1200x4000 mm

    2. Or 1200x size required by customer up to 4 mt.

    1B) Partition Wall Panels-(Inbuilt Riser)

    Moc, Construction, Insulation , Installation & Size ( Same as 1A)

    Inbuilt Riser Duct ( 400x 80, 600x80) MOC of duct - G.I. 14 Swg.

    M.S. Powder coated Grill.

    1C) Partition Wall Panels-(View Window)

    Moc, Construction, Insulation , Installation & Size ( Same as 1A)

    View window of size 900 (w) x 900(H) MM Toughen Glass

    Silica Gel for create vacuum between two glass.

    2) Ceiling Panel - Moc, Construction, Insulation , Installation & Size ( Same as 1A)

    MS Suspension rod with accessories for ceiling panels.

    Cut outs for Hepa , Tube light & Return ( if required)

    3) Clean Room Doors-

    Moc, Construction, Insulation ( Same as 1A)

    With Accessories1. Door closer ( Dorma Make)

    2. Ball bearing Hinges 5

    3. Door seal4. Door Handle ( 10)

    5. Tower Bolt ( for Double Door)

    6. Door Frame

    7. View Window ( 700 x 500mm)8. Gasket

    9. Door Lock

    Types of Door

    1. Single Door

    2. Double Door

    SIZES-1. 750 x 2100(h) mm

    2. 900 x 2100 (h) mm

    3. 1000 x 2100(h)mm4. 1200x 2100 (h) mm

    5. 1500x 2100 (h) mm

    4) Coving- : Aluminum / PVC Extruded covings .

    5) Grills -: M.S. Powder coated

    Physical Properties

  • 8/4/2019 Upvc Wall Panal

    13/13

    Sheer strength - 2.0 kg/ cm2

    Bending strength - 2.0~5.0 kg/ cm2

    Tensile strength - 3.0~5.0 kg/ cm2

    Temp Range - -196 0c/ +230 0c


Recommended