IMPORTANT SAFETY INSTRUCTIONS1. Readtheseinstructions.
2. Keeptheseinstructions.
3. Heedallwarnings.
4. Followallinstructions.
5. Donotusethisapparatusnearwater.
6. Cleanonlywithdrycloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturer’sinstructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or otherapparatus(includingamplifiers)thatproduceheat.
9. Donotdefeatthesafetypurposeofthepolarizedorgrounding-typeplug.Apolarizedplughastwobladeswithonewiderthantheother.Agroundingtypeplughastwobladesandathirdgroundingprong.Thewidebladeorthethirdprongareprovidedforyoursafety.Iftheprovidedplugdoesnotfitintoyouroutlet,consultanelectricianforreplacementoftheobsoleteoutlet.
10. Protectthepowercordfrombeingwalkedonorpinchedparticularlyatplugs,conveniencereceptacles,andthepointwheretheyexitfromtheapparatus.
11. Onlyuseattachments/accessoriesspecifiedbythemanufacturer.
12. Useonlywiththecart,stand,tripod,bracket,ortablespecifiedbythemanufacturer,orsoldwiththeapparatus.Whenacartisused,usecautionwhenmovingthecart/apparatuscombinationtoavoidinjuryfromtip-over.
13. Unplugthisapparatusduringlightningstormsorwhenunusedforlongperiodsoftime.
14. Referallservicingtoqualifiedservicepersonnel.Servicingisrequiredwhentheapparatushasbeendamaged inanyway,suchaspower-supplycordorplug isdamaged, liquidhasbeenspilledorobjectshavefallenintotheapparatus,theapparatushasbeenexposedtorainormoisture,doesnotoperatenormally,orhasbeendropped.
15. Nonakedflames,suchaslightedcandles,shouldbeplacedontheapparatus.
The appliance coupler is used as the disconnect device, the disconnect device shall remain readilyoperable.
Donotuseadamagedorfrayedpowercord.
Ifthemainsplugsupplyingtheapparatusincorporatesafusethenitshouldonlybereplacedwithafuseofidenticalorlowerrupturevalue.
Theapparatusshallbeconnectedtoamainssocketoutletwithaprotectiveearthingconnection.
Laiteonliitettäväsuojamaadoituskoskettimillavarustettuumpistorasiaan
Apparatetmåtikoplesjordetstikkontakt
Apparatenskallanslutastilljordatuttag
GB
FIN
NOR
SWE
3
Compliance Information Statement: Declaration of Compliance procedure
ProductIdentification:FocusriteRedNet
Responsibleparty:AmericanMusicandSound
Address:4325ExecutiveDrive
Suite300
Southaven
MS38672
Telephone:800-431-2609
Thisdevicecomplieswithpart15oftheFCCRules.Operationissubjecttothefollowingtwoconditions:(1)Thisdevicemaynotcauseharmful interference,and (2) this device must acceptany interference received, including interference that may cause undesiredoperation.
ENVIRONMENTAL DECLARATION
For USATo the User:
1.Do not modify this unit!Thisproduct,wheninstalledasindicatedintheinstructionscontainedinthismanual,meetsFCCrequirements.ModificationsnotexpresslyapprovedbyFocusritemayvoidyourauthority,grantedbytheFCC,tousethisproduct.
2. Important:ThisproductsatisfiesFCCregulationswhenhighqualityshieldedcablesareusedtoconnectwithotherequipment.FailuretousehighqualityshieldedcablesortofollowtheinstallationinstructionswithinthismanualmaycausemagneticinterferencewithappliancessuchasradiosandtelevisionsandvoidyourFCCauthorizationtousethisproductintheUSA.
3.Note:ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassAdigitaldevice,pursuanttopart15oftheFCCRules.Theselimitsaredesignedtoprovidereasonableprotectionagainstharmfulinterferenceinacommercialenvironment.Thisequipmentgenerates,usesandcanradiateradiofrequencyenergyand,ifnotinstalledandusedinaccordancewiththeinstructions,maycauseharmfulinterferencetoradiocommunications.Operationofthisequipmentinaresidentialareaislikelytocauseharmfulinterferenceinwhichtheuserwillberequiredtocorrecttheinterferenceathisownexpense
For Canada
To the User:
ThisClassAdigitalapparatuscomplieswithCanadianICES-003.
CetappareilnumériquedelaclasseAestconformeàlanormeNMB-003duCanada.
Theexclamationpointwithinanequilateraltriangleisintendedtoalerttheusertothepresenceofimportantoperatingandmaintenance(servicing)instructions
intheliteratureaccompanyingtheappliance.
WARNING:TOREDUCETHERISKOFFIREORELECTRICSHOCK,DONOTEXPOSETHISAPPARATUSTORAINORMOISTUREANDOBJECTSFILLEDWITHLIQUIDS,SUCHASVASES,SHOULDNOTBEPLACEDONTHISAPPARATUS.
Thelightningflashwitharrowheadsymbol,withinequilateraltriangle,isintendedtoalert theusertothepresenceofuninsulated“dangerousvoltage”withintheproduct’s enclosure that may be of sufficient magnitude to constitute a risk ofelectricshocktopersons.
CAUTION:TOREDUCETHERISKOFELECTRICSHOCK,DONOTREMOVECOVER(ORBACK).NOUSER-SERVICEABLEPARTSINSIDE.REFERSERVICINGTOQUALIFIEDSERVICEPERSONNEL.
RoHS Notice
FocusriteAudioEngineeringLimitedhasconformedwhereapplicable,totheEuropeanUnion’sDirective2002/95/EConRestrictions
ofHazardousSubstances(RoHS)aswellasthefollowingsectionsofCalifornialawwhichrefertoRoHS,namelysections25214.10,
25214.10.2,and58012,HealthandSafetyCode;Section42475.2,PublicResourcesCode.
4
IMPORTANT SAFETY INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5AboutthisUserGuide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
BoxContents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
INSTALLATION GUIDE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7UnitConnectionsandFeatures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
RedNet1-FrontPanel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
RedNet1-RearPanel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
PhysicalCharacteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
PowerRequirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
OTHER REDNET SYSTEM COMPONENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
USING REDNET CONTROL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
APPENDIx . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11ConnectorPinouts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
PerformanceSpecifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
FocusriteRedNetWarrantyandService. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
RegisteringYourProduct . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
CustomerSupportandUnitServicing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
TABLE OF CONTENTS
5
INTRODUCTIONThankyouforpurchasingthisFocusriteRedNet1.
RedNet 1 is a multichannel, bidirectional analogue interface for use with a RedNet digital audionetworkingsystem.
RedNetisapowerful,lowlatency,digitalaudionetworkingsystemdesignedspecificallyformusic,recordingstudioandbroadcastapplications.ItisbasedonAudinate’sDante™,awell-establishedaudionetworkingtechnologyknownforitsextremerobustness.Dante-andtheRedNetsystem-iscapableoftransportingupto512channelsofbidirectionalaudio(at48kHzsamplerate)overasingleGigabitEthernetlink.ThenumberofchannelsavailableinyourDAWwilldependonthehostmethodbeingused.
RedNet1provideseightanalogue inputsandeightanalogueoutputs.A-DandD-Aconversion is24-bitatsampleratesofupto192kHz,andupto119dBofdynamicrangeisachievable.JetPLL™technologyisemployedtominimiseconversionjitter.
Theanalogueinputsandoutputsareelectronicallybalancedon25-pinDsubconnectors.Theunitcanbeconfiguredwith0dBFSequatingtoeither+18dBuor+24dButoconformtotheEBUorSMPTE-RP155standardsrespectively.
ThefrontpanelcontainsasetofLEDsconfirmingnetworkstatus,samplerate,referencelevelandper-channelsignallevel.
About this User GuideThis User Guide applies only to the RedNet 1 analogue interface. It provides information aboutinstallingaRedNet1andhowtoconnectitintoyourstudiosystem.
YouwillalsofindacopyoftheRedNetSystemUserGuideincludedwiththeunit.ThisGuideprovidesadetailedexplanationoftheRedNetsystemconcept,tohelpyouachieveathoroughunderstandingofitscapabilities.Werecommendthatallusers,includingthosealreadyexperiencedindigitalaudionetworking,takethetimetoreadthroughtheSystemUserGuidesothatyouarefullyawareofallthepossibilitiesthatRedNetanditssoftwarehastooffer.
IfeitherUserGuidedoesnotprovidetheinformationyouneed,besuretoconsult www.focusrite.com/rednet,whichcontainsacomprehensivecollectionofcommontechnicalsupportqueries.
6
Box Contents• RedNet1unit• RedNet1UserGuide(thismanual)• RedNetSystemUserGuide• 2mCat6Ethernetcable• IECACmainscable• ProductregistrationcardwithBundleCode.Registrationgivesaccessto:
•RedNetControl•RedNetdrivers(installedwithRedNetControl)•AudinateDanteController(installedwithRedNetControl)•DanteVirtualSoundcardtokenanddownloadinstructions•RedNet1UserGuide(thisdocument)–PDFformat•RedNetSystemUserGuide–PDFformat
7
INSTALLATION GUIDE
Unit connections and features
RedNet 1 - Front Panel
12
3
4
5
1. ACPowerswitch
2. TricolourLEDsindicatingsignallevelateachA-DandD-Aconverter:
•Green–signallevelabove-42dBFS•Yellow–signallevelabove-6dBFS•Red–signallevelis0dBFS(digitalclipping)
3. NETWORKstatusflags–twogreenLEDsconfirmingnetworkstatus:
•CONNECTED–illuminateswhentheunitisconnectedtoanactiveEthernetnetwork•LOCKED–illuminateswhenavalidsyncisreceivedviathenetwork
4. SAMPLE RATEindication–fiveyellowLEDs;onlyoneofthese(44 .1 kHz,48 kHz,88 .2 kHz,96 kHz,192 kHz)willbelitatatime,toconfirmthesampleratethatthesystemisrunningat.
5. LEVEL SETUPindication–twoyellowLEDs;oneofthesewillbeilluminatedtoconfirmtheanaloguereferencelevelsetfortheunit,+24 dBuor+18 dBu.Thisistheanaloguelevelwhichequatestotheinternalmaximumdigitalcliplevelof0dBFS.
8
RedNet 1 - Rear Panel
678
9
6. ANALOGUE INPUTS 1-8 – 25-pin female Dsub connector for connecting up to 8 analoguesources to the RedNet system. All inputs are electronically balanced. See page 11 forconnectordetails.
7. ANALOGUE OUTPUTS 1-8–25-pinfemaleDsubconnectorwith8analogueoutputsfromtheRedNetsystem.Alloutputsareelectronicallybalanced.Seepage11forconnectordetails.
8. ETHERNET –RJ45networksocket.UseastandardcomputernetworkcabletoconnectthissockettoalocalEthernetswitchtoconnecttheRedNet1totheRedNetnetwork.Thesockethas integral LEDs which illuminate to indicate connection to an active network port, andnetworkactivity.Seepage12forconnectordetails.
9. ACmains–standardIECreceptacleforconnectionofACmains.RedNet1hasa‘Universal’PSU,enablingittooperatefromanysupplyvoltagesbetween100Vand240V.
9
Physical CharacteristicsRedNet1’sdimensionsareshowninthediagrambelow:
465.0mm / 18.30"
76.2mm / 3"
247.5mm / 9.74"
RedNet1requires2Uofverticalrackspaceandatleast350mmofrackdepth,toallowforcables.RedNet1weighs4.12kgandforinstallationsinafixedenvironment(e.g.,astudio),thefrontpanelmountingscrewswillprovideadequatesupport. If theunitsare tobeused inamobilesituation(e.g.,flight-casedfortouring,etc.),considerationshouldbegiventousingsidesupportrailswithintherack.
RedNet1generatesnosignificantheat,and isnormallycooledbynaturalconvection, thoughaninternalcoolingfanisfitted.Werecommendthattheunitshouldnotbeusedinlocationswheretheambienttemperatureisgreaterthan30°C.However,ifthisisunavoidable,thefancanbeturnedonandofffromRedNetControl.
Ventilationisviaslotsintheenclosureatbothsides.DonotmountRedNet1immediatelyaboveanyotherequipmentwhichgeneratessignificantheat,forexample,apoweramplifier.Also,ensurethatwhenmountedinarack,thesideventsarenotobstructed.
Power requirementsRedNet1ismains-powered.Itincorporatesa‘Universal’powersupply,whichcanoperateonanyACmainsvoltagefrom100Vto240V.TheACconnectionismadeviaastandard3-pinIECconnectorontherearpanel.AmatingIECcableissuppliedwiththeunit,whichshouldbeterminatedwithamainsplugofthecorrecttypeforyourcountry.
TheACpowerconsumptionoftheRedNet1is30VA.
PleasenotethattherearenofusesinRedNet1,orotheruser-replaceablecomponentsofanytype.PleasereferallservicingissuestotheCustomerSupportTeam(see“CustomerSupportandUnitServicing”onpage14).
10
OTHER REDNET SYSTEM COMPONENTSTheRedNethardwarerangeincludesvarioustypesofI/OinterfaceandaPCIedigitalaudiointerfacecardwhichisinstalledinthesystem’shostcomputer.AlltheI/Ounitscanbeconsideredas“Break-Out” (and/or “Break-In”) boxes to/from the network, and all are built in mains-powered, 2U 19”rackmountinghousings.Therearealso threesoftware items,RedNetControl (seebelow),DanteControllerandDanteVirtualSoundcard.
USING REDNET CONTROLAvirtualdepictionofRedNet1willappearon-screeninRedNetControlwhenaunitisincludedintheactivesystem.
Metering:Each inputandoutputhas3virtualLEDscorresponding to the levels indicatedby thetricolour LEDs on the physical front panel. These illuminate at -42 dBFS, -6 dBFS and 0 dBFSrespectively.
Tools menu :fouroptionsareoffered:•Level Ref +24 dBu–setsinternalanaloguereferencelevelfor0dBFSto+24dBu•Level Ref +18 dBu–setsinternalanaloguereferencelevelfor0dBFSto+18dBu
ThecorrespondingfrontpanelLEDsilluminatetoconfirmthereferencelevel.
•Preferred Master-allowstheusertosettheunittobethesystemmasterclocksource•Cooling Fan–turnsthecoolingfanonandoff.
11
APPENDIx
Connector pinouts8-channelanalogueinputandoutputconnectors
Connectortype: 25-pinfemaleDsubAppliesto: ANALOGUEINPUTS1-8 ANALOGUEOUTPUTS1-8
Pin Signal Pin Signal
1 Ch8‘hot’(+) 14 Ch8‘cold’(-)
2 Ch8screen 15 Ch7‘hot’(+)
3 Ch7cold(-) 16 Ch7screen
4 Ch6‘hot’(+) 17 Ch6‘cold’(-)
5 Ch6screen 18 Ch5‘hot’(+)
6 Ch5cold(-) 19 Ch5screen
7 Ch4‘hot’(+) 20 Ch4‘cold’(-)
8 Ch4screen 21 Ch3‘hot’(+)
9 Ch3cold(-) 22 Ch3screen
10 Ch2‘hot’(+) 23 Ch2‘cold’(-)
11 Ch2screen 24 Ch1‘hot’(+)
12 Ch1cold(-) 25 Ch1screen
13 n/c
12
Ethernetconnector
Connectortype: RJ-45receptacleAppliesto: ETHERNET
11
8 1
8
Pin Cat6 Core
1 White+Orange
2 Orange
3 White+Green
4 Blue
5 White+Blue
6 Green
7 White+Brown
8 Brown
13
Performance Specifications
Inputs
Analoguelineinputs 8
Connector 25-wayfemaleDsub,wiredtoAES59
0dBFSreferencelevels +18or+24dBu(switchable)
Frequencyresponse 20Hz–20kHz±0.05dB
THD+N < 0.001%unweighted;-1dBFSinput,20Hz–22kHz
Dynamicrange 119dB‘A’-weighted(-60dBFSmethod)
Converterdynamicrange 120dB
Signal-to-noiseratio 119dB‘A’-weighted;20Hz–20kHz
Outputs
Analoguelineoutputs 8
Connector 25-wayfemaleDsub,wiredtoAES59
0dBFSreferencelevels +18or+24dBu(switchable)
Frequencyresponse 20Hz–20kHz±0.15dB
THD+N < 0.001%unweighted;-1dBFSinput,20Hz–22kHz
DynamicRange 119dB‘A’-weighted(-60dBFSmethod)
Converterdynamicrange 120dB
Signal-to-noiseratio 119dB‘A’-weighted;20Hz–20kHz
Crosstalk
InputorOutputtoInput <-90dB(allotherchannelsat0dBFS)
InputorOutputtoOutput <-100dB(allotherchannelsat0dBFS)
Digital Performance
Supportedsamplerates 44.1/48/88.2/96/192kHz
Clocksources Internalorfromnetworkmasterdevice
Power
PSU Internal,Universaltype,consumption30VA
Front Panel Indicators
Power Green
Networkconnected Green
Synclock Green
Samplerate Yellowx5
Input/Outputrange Yellowx2
Input/Outputsignallevel Bi-colourx16(Green=-42dBFS;Orange=-6dBFS;Red=overload)
14
Focusrite RedNet Warranty and ServiceAllFocusriteproductsarebuilttothehigheststandardsandshouldprovidereliableperformanceformanyyears,subjecttoreasonablecare,use,transportationandstorage.
Verymanyoftheproductsreturnedunderwarrantyarefoundnottoexhibitanyfaultatall.ToavoidunnecessaryinconveniencetoyouintermsofreturningtheproductpleasecontactFocusritesupport.
IntheeventofaManufacturingDefectbecomingevidentinaproductwithin12monthsfromthedateoftheoriginalpurchaseFocusritewillensurethattheproductisrepairedorreplacedfreeofcharge.
AManufacturingDefectisdefinedasadefectintheperformanceoftheproductasdescribedandpublishedbyFocusrite.AManufacturingDefectdoesnotincludedamagecausedbypost-purchasetransportation,storageorcarelesshandling,nordamagecausedbymisuse.
WhilstthiswarrantyisprovidedbyFocusritethewarrantyobligationsarefulfilledbythedistributorresponsibleforthecountryinwhichyoupurchasedtheproduct.
Intheeventthatyouneedtocontactthedistributorregardingawarrantyissue,oranout-of-warrantychargeablerepair,pleasevisit:www.focusrite.com/distributors
Thedistributorwillthenadviseyouoftheappropriateprocedureforresolvingthewarrantyissue.Ineverycase itwillbenecessary toprovideacopyof theoriginal invoiceorstorereceipt to thedistributor. Intheeventthatyouareunabletoprovideproofofpurchasedirectlythenyoushouldcontacttheresellerfromwhomyoupurchasedtheproductandattempttoobtainproofofpurchasefromthem.
PleasedonotethatifyoupurchaseaFocusriteproductoutsideyourcountryofresidenceorbusinessyouwillnotbeentitledtoaskyourlocalFocusritedistributortohonourthislimitedwarranty,althoughyoumayrequestanout-of-warrantychargeablerepair.
ThislimitedwarrantyisofferedsolelytoproductspurchasedfromanAuthorisedFocusriteReseller(definedasaresellerwhichhaspurchasedtheproductdirectlyfromFocusriteAudioEngineeringLimitedintheUK,oroneofitsAuthorisedDistributorsoutsidetheUK).ThisWarrantyisinadditiontoyourstatutoryrightsinthecountryofpurchase.
Registering your product
Fortechnicalsupport,pleaseregisteryourproductat:www.focusrite.com/register
Customer Support and Unit Servicing
YoucancontactFocusriteCustomerSupportat:Email:[email protected](UK): +44(0)1494462246Phone(USA): +1(310)322-5500
Troubleshooting IfyouareexperiencingproblemswithyourRedNet1,werecommendthatinthefirstinstance,youvisitourSupportAnswerbaseat:www.focusrite.com/answerbase
15