Page 1: User Guide for SMH Negative Pressure Unitssmhproducts.com/media/NPU-UG-UK-v4.pdfThe NPU is to be operated under the supervision of competent and trained operators. NOTE Attention is

 

User Guide for SMH Negative Pressure Units

 

 

 

 

 

 

 

 

 

 

 

 

   

SMH Equipment Ltd, a part of the SMH Group · SMH House, Maxwell Street, South Shields, NE33 4PU, UK Tel: +44 (0)191 456 6000 · Fax: +44 (0)191 456 7777 · [email protected] 

www. smh products.com NPU - UG - UK - v4 

Page 2: User Guide for SMH Negative Pressure Unitssmhproducts.com/media/NPU-UG-UK-v4.pdfThe NPU is to be operated under the supervision of competent and trained operators. NOTE Attention is

 

Index  

1. Foreword 3 

1.1 Guide to pictograms used 3 

1.2 The unit 3 

1.3 Intended use 3 

2. Safety information 4 

3. Technical specifications 5 

3.1 Technical Data 5 

3.2 Dimensions 6 

3.3 Technical drawings 7 

3.3.1 Standard NPU Motor Plate 7 

3.3.2 Standard NPU Side View 8 

4. Standard Operating Procedures 9 

4.1 Transport of the unit 9 

4.2 Operation of the unit 9 

4.2.2 Using Roving Filter boxes 11 

4.3 Shut down of the unit 11 

5. Maintenance of the unit 13 

5.1 Regular inspections 13 

5.2 Maintenance 13 

5.3 Servicing regime 15 

6. Declaration of conformity 16 

7. Maintenance / Service record 17  

Please note, we make every effort to ensure that the information provided in all our material is accurate and up to date, but to the extent permitted by law, we do not accept any legal responsibility for any errors, omissions or misleading statements. If you have any questions about any part of this user guide, please do not hesitate to contact SMH direct for more information. 

 

2 /17 

www. smh products.com 

Page 3: User Guide for SMH Negative Pressure Unitssmhproducts.com/media/NPU-UG-UK-v4.pdfThe NPU is to be operated under the supervision of competent and trained operators. NOTE Attention is

 

1. Foreword This user guide must be read in conjunction with the information plate and any safety warning labels or signs on the unit, and any use of the unit must also be in line with site controls and any local/national legislation controlling the work to be completed. 

An NPU should only be used and installed by a competent trained person. It should only be used when provided with an in-date DOP and electrical test certificate. 

Please note that any non-observance of this user guide may invalidate any warranty associated with the product.  

We recommend all users complete equipment competency training provided by SMH. See our website for more information. 

1.1 Guide to pictograms used

⚠  Text in a box like this is information critical to the safe operation of the unit 

 

✓  Text in a box like this is a recommendation to help users to operate the unit in the most efficient/effective way 

1.2 The unit

The unit as bought/hired consists of: 

1. The unit 2. This user guide 

1.3 Intended use

SMH Negative Pressure Units are portable/transportable NPUs incorporating HEPA (High Efficiency Particulate Air) filters covered by BS EN 1822 for use in the controlled removal of asbestos-containing materials (ACMs). They are designed to create negative pressure within a portable decontamination unit facility or working enclosure. 

Please note, local regulations may demand a different set-up. 

   

3 /17 

www. smh products.com 

Page 4: User Guide for SMH Negative Pressure Unitssmhproducts.com/media/NPU-UG-UK-v4.pdfThe NPU is to be operated under the supervision of competent and trained operators. NOTE Attention is

 

2. Safety information  This section provides a summary of all the safety information provided throughout the user guide. 

⚠ Power Rating. The NPUs are supplied in 110v or 230v models. Correct connection of a power supply that provides voltage and current within the specified rating of the system. Use of an incompatible power supply could result in electric shock or fire hazards. 

 

⚠  Electrical Grounding. The NPU has been designed for use with electrical supplies that incorporates a functional earth. Do not connect to a supply that does not have a functional earth facility. 

 

⚠  Internal Voltage. Always turn off the NPU and disconnect the power cord prior to any service, maintenance or cleaning or when not in use. 

 

⚠  Asbestos Exposure. Never remove filters in a non-controlled environment and always use a respirator and appropriate PPE. 

 ⚠  Heavy Equipment. Some of the equipment is extremely heavy to li�. 

 

⚠ 

PLEASE NOTE: The use of ancillary items such as roving filter heads and/or exhaust ducts can significantly reduce airflow through the NPU. RR988 HSL Research Project – The addition of flexible ducting reduced the volume airflow rate by approx. 1% per metre of ducting and by 2% for a 90deg bend. Based on ducting of 355mm diameter being used and thus significantly reduce the amount of negative pressure achieved within the working enclosure. The accurate monitoring of the negative pressure within the enclosure can only be achieved using an external monitoring device – the manometer fitted to the NPU is not an indicator of negative pressure within the enclosure. You may require additional NPUs to mitigate any shortfalls in performance. 

 

⚠  All personnel engaged in decontamination must follow the health and safety protocols described in the current legislation and guidance. 

 

⚠ The NPU is to be operated under the supervision of competent and trained operators. NOTE Attention is drawn to the Control of Asbestos Regulations, Regulation 13 [1], [2]. It should only be used when provided with an in-date DOP and electrical test certificate. The NPU should not be le� running unattended at any time. 

 

⚠ Filters should be changed under controlled conditions by a qualified, competent person wearing full PPE and RPE. Filters must be disposed of in accordance with local regulations for the removal of asbestos-containing materials and within any site-specific method statements. 

 

⚠ The NPU must be examined and serviced in accordance with UK legislation and the approved code of practice, at least once every six months by an SMH branch or recommended service centre. NPUs sold outside of the UK must be examined and serviced at least once every 12 months and in accordance with local regulations and approved codes of practice. 

 

4 /17 

www. smh products.com 

Page 5: User Guide for SMH Negative Pressure Unitssmhproducts.com/media/NPU-UG-UK-v4.pdfThe NPU is to be operated under the supervision of competent and trained operators. NOTE Attention is

 

3. Technical specifications 

3.1 Technical Data   MSA 300  DECON 300  DECON 500  DECON 850  NPU 500  NPU 850  NPU 1000  NPU 

2500+ NPU 

5000+ 

Case material  Polypropylene  Polyethylene  Polyethylene 

Default Case colour  White  White  White  White  Grey  Grey  Grey  Grey  Grey 

Weight (kg)  13  12  16  18  19  20  31  46  84 

Voltage (v)  110 / 230  230  230  230  230  110 / 230  110 / 230  110 / 230  110 / 230 

Calculated load current (a)  0.51 / 0.24  0.24  1.19  1.79  1.19  3.71 / 1.79  3.71 / 1.79  14 / 7 

14(per inlet) / 14 

Motor power (w)  57 / 55  55  268  411  268  426 / 411  426 / 411  1000  1000 (per inlet) / 2000 

Average airflow (m3/h) 

208/230  208  495  796  495  752/796  1147/1367  2802/ 2889  5228 / 5244 

Average airflow (cfm)* 

122/135  122  291  469  291  443/469  675/805  1649/ 1700  3077 / 3087 

Maximum Motor noise level (db) 

66   81  84  86  84  86  86  88  88 

Differential pressure gauge (pa) 

0-1250  0-1250  0-1250  0-1250  0-1250  0-1250  0-1250  0-1250  0-1250 

Isolation on/off switch 

No  No  No  No  Yes  Yes  Yes  Yes  Yes 

Electrical Protection  N/A  6A MCB on Decon 

6A MCB on Decon 

6A MCB on Decon 

6A RCBO  None / 6A RCBO 

None / 6A RCBO 

16A MCB/ 16A RCBO 

16A MCB/ 16A RCBO 

Prefilter Dimensions (mm) 

296x296x47  296x296x47  296x296x47  296x296x47  296x296x47  296x296x47  372x372x98  450x450x98  596x596x98 

HEPA Filter Dimensions (mm) 

305x305x68  305x305x68  305x305x150  305x305x150  305x305x150  305x305x150  381x381x150  457x457x292  610x610x292 

Optional Extras 

Hour meter  Yes  Yes  Yes  Yes  Yes  Yes  Yes / As Standard 

Yes / As Standard 

Yes / As Standard 

Airflow Monitor  Yes  Yes  Yes  Yes  Yes  Yes  Yes  Yes  Yes 

Variable speed control  Yes  Yes  Yes  Yes  Yes  Yes  Yes  Yes  Yes 

Available Accessories 

Available roving filter No  No  No  No  Yes  Yes  Yes  Yes  Yes 

Available spigot plate No  No  No  No  Yes  Yes  Yes  Yes  Yes 

Spigot Diameter mm N/A  N/A  N/A  N/A  150  200  300  300  400 

Ducting internal diameter mm

N/A  N/A  N/A  N/A  155  205  305  305  405 

Double HEPA Attachment

No  No  No  No  No  No  Yes  Yes  Yes 

Clear Cover Plate No  No  No  No  No  No  Yes  Yes  Yes 

Reducer Boxes No  No  No  No  No  No  No  1500  No 

*All information accurate as of date of issue, contact supplier for any queries 

5 /17 

www. smh products.com 

Page 6: User Guide for SMH Negative Pressure Unitssmhproducts.com/media/NPU-UG-UK-v4.pdfThe NPU is to be operated under the supervision of competent and trained operators. NOTE Attention is

 

3.2 Dimensions

 

 

  MSA 300  DECON 300  DECON 500  DECON 850  NPU 500  NPU 850  NPU 1000  NPU 2500+  NPU 5000+ Case length A  300  270  400  400  410  450  580  850  850 Case width B  375  375  375  375  375  375  455  620  806 Case height C  450  375  375  375  400  400  455  530  700 Floor clearance height D  N/A  N/A  N/A  N/A  N/A  N/A  105  105  105 Exhaust outlet diameter E  150  105 x 105  105 x 105  105 x 105  150  200  300  300  400 Exhaust outlet depth F  80  70  70  70  80  80  70  85  80 Cover plate width G  375  375  375  375  425  425  505  635  810 Cover plate height H  375  375  375  375  425  425  505  580  750 

All dimensions in mm 

   

6 /17 

www. smh products.com 

Page 7: User Guide for SMH Negative Pressure Unitssmhproducts.com/media/NPU-UG-UK-v4.pdfThe NPU is to be operated under the supervision of competent and trained operators. NOTE Attention is

 

3.3 Technical drawings

Please note, all drawings are indicative only – individual units may differ. 

Warning labels on the unit are as follows: 

■ WARNING: For use by certified, trained operators only. Handle with care: high efficiency air filtering equipment. Not to be used within a working enclosure. 

■ WARNING: The manufacturer’s instructions must be read, understood and followed in the use of this equipment. 

■ The unit shall bear a red and white H (hazardous) label, as specified in BS EN 60335-2.69. 

3.3.1 Standard NPU Motor Plate  

 

7 /17 

www. smh products.com 

Page 8: User Guide for SMH Negative Pressure Unitssmhproducts.com/media/NPU-UG-UK-v4.pdfThe NPU is to be operated under the supervision of competent and trained operators. NOTE Attention is

 

3.3.2 Standard NPU Side View 

 3.3.3 Spare Parts 

Spare Part Product Codes Item No.  Part Name  NPU 1000  NPU 2500+  NPU 5000+ 

1  Rocker Switch  B001101 / 90007-EL  B001101 / 90007-EL  B001101 / 90007-EL 

2  Hour Counter  POA  POA  POA 

3  Non-return Flap  B001656 / 90137-EL  POA  POA 

4  110V inlet/ 230V inlet 

B001248 /90032-EL / B001274 / 90048-EL 

B001248 /90032-EL / B001274 / 90048-EL 

B001248 /90032-EL / B001274 / 90048-EL 

5  Motor Plate  POA  POA  POA 

6  10mm Bulkhead Connector  B000085 / 91232-ST  B000085 / 91232-ST  B000085 / 91232-ST 7  Variable Flow Controller  POA  POA  POA 8  Airflow Monitor  B004747 / 91659-EL  B004747 / 91659-EL  B004747 / 91659-EL 

9  Manometer  B001579 / 90121-EL  B001579 / 90121-E  B001579 / 90121-E 

10  Electrical Protection Enclosure  B001264 / 90040-EL  B001264 / 90040-EL  B001264 / 90040-EL 

11  110/230V Motor  B001586 / 90127-EL  B001586 / 90127-EL  B001586 / 90127-EL 

12  Braked Castor  B001575 / 90117-EL  B001575 / 90117-EL  B001575 / 90117-EL 

13  NPU Body  POA  POA  POA 

14  NPU Handle  B001582 / 90123-EL  N/A  N/A 

15  Unbraked Castor  B001581 / 90122-EL  B001581 / 90122-EL  B001581 / 90122-EL 

16  HEPA Filter  B004624 / 91106-EL  B002219 / 90159-EL  B002220 / 90160-EL 

17  HEPA Push Plate  POA  POA  POA 

18  Clip Strikes  B001583 / 90124-EL  B001583 / 90124-EL  B001583 / 90124-EL 

19  Prefilter  B001048 / 90004-EL  B001049 / 90005-EL  B001050 / 90006-EL 

20  Cover Plate  B001560 / 91262-EL  B001552 / 91173-EL  B001561 / 90869-EL 

21  Over Centre Clips  B001549 / 90119-EL  B001549 / 90119-EL  B001549 / 90119-EL 

8 /17 

www. smh products.com 

Page 9: User Guide for SMH Negative Pressure Unitssmhproducts.com/media/NPU-UG-UK-v4.pdfThe NPU is to be operated under the supervision of competent and trained operators. NOTE Attention is

 

4. Standard Operating Procedures The purpose of the SMH negative pressure unit standard operating procedure is to provide guidance for the correct and safe method of use of the units. 

⚠  All personnel engaged in decontamination must follow the health and safety protocols described in the current legislation and guidance. 

 

⚠ The NPU is to be operated under the supervision of competent and trained operators. NOTE Attention is drawn to the Control of Asbestos Regulations, Regulation 13 [1], [2]. It should only be used when provided with an in-date DOP and electrical test certificate. The NPU should not be le� running unattended at any time. 

 

Please note, all photographs are indicative only – individual units may differ. If in any doubt, please contact your local SMH branch. 

4.1 Transport of the unit

Care should be taken when transporting an NPU. NPUs should be assessed before attempting to li� them from a van or working area. Secure li�ing handles are ergonomically positioned to assist when li�ing NPUs. 

Ensure the NPU is securely located before transporting. The NPU must only be transported in a decontaminated state. 

Ensure that the transit cover plate is fitted securely to protect and seal the pre-filter during transit. 

Handle the NPU with due care and attention, and avoid manhandling while in operation. 

4.2 Operation of the unit The unit must be placed on a hardened, vibration-free floor. The unit should be used indoors and kept dry and within a temperature range of +5°C to +40°C. 

4.2.1 Running the unit 

 

The NPU will require a 110v or 230v 16amp power supply. Extend the NPU supply cable to the power outlet and plug in the supply plug to the mains outlet. 

 

9 /17 

www. smh products.com 

Page 10: User Guide for SMH Negative Pressure Unitssmhproducts.com/media/NPU-UG-UK-v4.pdfThe NPU is to be operated under the supervision of competent and trained operators. NOTE Attention is

 

 

With the cover plate attached, turn on the NPU using the rocker switch located on the NPU body. Remove the cover plate when the unit is running to prevent possible fibre release. 

 

Remove the cover plate by unclipping the NPU over centre clips. If necessary switch off the NPU to reduce the suction on the pressure plate. Remove the plate and turn the NPU back on. 

 

Ensure that a clean pre-filter is fitted to the NPU and that it has been taped into place. 

 

 

Check that the manometer reading on the unit is within its safe operating pressure. The manometer is colour coded to indicate its safe working pressure. 

 

The NPU can now be attached to an enclosure wall and can be fitted with ducting to extract to atmosphere wherever possible. The option is also available to add a spigot and roving filter box to control fibres at source. 

 

 

When the NPU has been installed, ensure that the brakes are applied on the castors of the NPU to help prevent any movement. 

 

10 /17 

www. smh products.com 

Page 11: User Guide for SMH Negative Pressure Unitssmhproducts.com/media/NPU-UG-UK-v4.pdfThe NPU is to be operated under the supervision of competent and trained operators. NOTE Attention is

 

4.2.2 Using Roving Filter boxes 

⚠ The use of ancillary items such as roving heads or exhaust ducts can significantly reduce the airflow through an NPU, which in turn will reduce the negative pressure within the enclosure. RR988 HSL Research project estimates a 1% drop in volume airflow rate for each metre of 355mm ducting used. 

 

 

If you are using a spigot plate with room for an additional prefilter, the prefilter can be fitted into the spigot plate as fitted into the NPU pre-filter plate (see 5.2.1 Procedure for changing NPU pre-filters). 

Attach the flexible ducting using a suitable clip or tape to secure it to the spigot plate/box. 

To attach ducting to the NPU, attach the NPU spigot plate to the NPU using its original strikes and over centre clips or by using PCL tape. Pre-filter should be installed into the roving head filter housing – we do not advise using 2 pre-filters. 

4.3 Shut down of the unit

✓  Following the correct procedure is not only important to ensure the safe shutdown of your unit – it will also extend the life of your unit, avoiding unnecessary damage and potentially costly repairs. 

4.3.1 Procedure for shutting down the NPU 

 

Before an NPU is removed from the enclosure, ensure that a clean pre-filter has been fitted. 

 

 

Seal the NPU using the transit cover plate to prevent fibre release during transportation. 

Switch off and unplug the unit. 

11 /17 

www. smh products.com 

Page 12: User Guide for SMH Negative Pressure Unitssmhproducts.com/media/NPU-UG-UK-v4.pdfThe NPU is to be operated under the supervision of competent and trained operators. NOTE Attention is

 

 

4.3.2 Storage of the unit 

Avoid extremes of temperature, damp conditions and/or dusty conditions. The unit must be stored only in a decontaminated state.  

4.3.3 Return of the unit a�er rental 

NPUs must be returned clean and free from any dust or debris, in a decontaminated state, i.e. with a clean pre-filter fitted, and without damage.  

Any customer returning a unit in an unsuitable state as deemed by the receiving SMH branch will be liable to additional charges. 

 

 

   

12 /17 

www. smh products.com 

Page 13: User Guide for SMH Negative Pressure Unitssmhproducts.com/media/NPU-UG-UK-v4.pdfThe NPU is to be operated under the supervision of competent and trained operators. NOTE Attention is

 

5. Maintenance of the unit  ⚠  The following maintenance procedures and advice for the procedures must be followed to ensure that the 

unit is kept in good working order. 

5.1 Regular inspections

5.1.1 Pre-use checks  Visual checks of electrical equipment for obvious defects should be carried out before each use. 

5.1.2 Daily checks 

■ Inspection and testing of electrical equipment should be done ■ Inspection, testing and, where required, replacement of HEPA filter ■ Inspection and maintenance of casings/fittings 

5.1.3 Weekly checks 

Every week, users should conduct a thorough visual check and inspection of all electrical equipment for damage or wear and tear. 

5.2 Maintenance

5.2.1 Procedure for changing NPU pre-filters 

⚠ Filters should be changed under controlled conditions by a qualified, competent person wearing full PPE and RPE. Filters must be disposed of in accordance with local regulations for the removal of asbestos-containing materials and within any site-specific method statements. 

 

 

Pre-filters should be changed regularly and only under controlled conditions. 

 

13 /17 

www. smh products.com 

Page 14: User Guide for SMH Negative Pressure Unitssmhproducts.com/media/NPU-UG-UK-v4.pdfThe NPU is to be operated under the supervision of competent and trained operators. NOTE Attention is

 

 

When taped to an enclosure, cut the pre-filter out of the NPU. Fit a new pre-filter into the NPU and seal it with PCL tape. 

 

Place the dirty pre-filter in a red asbestos bag and follow your company procedures to dispose of asbestos containing materials. 

 

Before an NPU is removed from the enclosure, ensure that a clean pre-filter has been fitted. 

 

 

Seal the NPU using the transit cover plate to prevent fibre release during transport. 

 

 

   

14 /17 

www. smh products.com 

Page 15: User Guide for SMH Negative Pressure Unitssmhproducts.com/media/NPU-UG-UK-v4.pdfThe NPU is to be operated under the supervision of competent and trained operators. NOTE Attention is

 

5.3 Servicing regime

⚠ The NPU must be examined and serviced in accordance with UK legislation and the approved code of practice, at least once every six months by an SMH branch or recommended service centre. NPU’s sold outside of the UK must be examined and serviced at least once every 12 months and in accordance with local regulations and approved codes of practice. 

 

 

NPUs used in the control of asbestos containing material must be serviced by a competent person to ensure they are working to their design specification. 

 

 

 

Please note: 

■ Any servicing not completed by an SMH branch or a competent and qualified person voids any product liability claim against us. 

■ Any replacement parts must be supplied by and fitted in an SMH branch or a competent and qualified person. 

■ Any modifications made to an SMH product a�er the product has been sold will void any product liability claim against us. 

■ Any use of the product other than that outlined in section 1.3, above, voids any product liability claim against us. 

 

 

 

 

   

15 /17 

www. smh products.com 

Page 16: User Guide for SMH Negative Pressure Unitssmhproducts.com/media/NPU-UG-UK-v4.pdfThe NPU is to be operated under the supervision of competent and trained operators. NOTE Attention is

 

6. Declaration of conformity In accordance with BS EN ISO/IEC 17050-1:2010 

WE: 

SMH Products Ltd, SMH House, Maxwell Street, South Shields NE33 4PU United Kingdom 

DECLARE ENTIRELY WITHIN OUR OWN AREA OF RESPONSIBILITY THAT THE PRODUCT: 

Negative Pressure Units (NPU) BRAND: SMH MODEL(S): NPU 300, NPU 500, NPU 850, NPU 1000, NPU 2500+, NPU 5000+,

NPU MSA 300, NPU DECON 300, NPU DECON 500, NPU DECON 850 SERIAL N°: 1200 onwards 

TO WHICH THIS STATEMENT APPLIES, IS IN ACCORDANCE WITH THE PROVISIONS OF THE FOLLOWING DIRECTIVES: 

Low Voltage Directive 2014/35/EU    AND IN ACCORDANCE WITH THE FOLLOWING STANDARDS AND THOSE REFERENCED THEREIN : 1

BS 8520-2:2009 (Equipment used in the controlled removal of asbestos-containing materials) BS EN 60335-2-69:2012 (Electrical appliances. Safety for wet and dry vacuum cleaners) 

 

AND MEETS THE REQUIREMENTS OF: 

HSG (Health and Safety Guidance) 247, Asbestos: the licensed contractors' guide, 2012 The Electrical Equipment (Safety) Regulations 1994 

I hereby declare that the product named above has been designed to comply with the relevant sections of the above referenced specifications. The product complies with all applicable Essential Requirements of the Directives.     

 

Dean Rowe, Chief Executive Officer of SMH Equipment Ltd South Shields, 01/08/2017 

   

1 The titles of some standards have been abbreviated 

16 /17 

www. smh products.com 

Page 17: User Guide for SMH Negative Pressure Unitssmhproducts.com/media/NPU-UG-UK-v4.pdfThe NPU is to be operated under the supervision of competent and trained operators. NOTE Attention is

 

7. Maintenance / Service record SMH Products Ltd recommends that all NPUs are serviced and maintained at least every 6 months at an SMH branch or by a competent and qualified person, and that servicing and maintenance frequencies of HEPA filter change are followed as laid out in BS 8520-2:2009. NPUs sold outside of the UK must be examined and serviced at least once every 12 months and in accordance with local regulations and approved codes of practice. 

NPU model    Serial number   

Purchase date    Branch   

 

Record       Date       Engineer       Branch       DOP  Pass ⬜ Fail ⬜  Pass ⬜ Fail ⬜  Pass ⬜ Fail ⬜ PAT  Pass ⬜ Fail ⬜  Pass ⬜ Fail ⬜  Pass ⬜ Fail ⬜ Airflow test Recorded airflow 

Pass ⬜ Fail ⬜ ______________ 

Pass ⬜ Fail ⬜ ______________ 

Pass ⬜ Fail ⬜ ______________ 

HEPA replaced  Y ⬜ N ⬜  Y ⬜ N ⬜  Y ⬜ N ⬜ Any visual damage  Y ⬜ N ⬜  Y ⬜ N ⬜  Y ⬜ N ⬜ Parts replaced Description of new parts fitted 

Y ⬜ N ⬜  

  

______________ 

Y ⬜ N ⬜   

 ______________ 

Y ⬜ N ⬜   

 ______________ 

 Record       Date       Engineer       Branch       DOP  Pass ⬜ Fail ⬜  Pass ⬜ Fail ⬜  Pass ⬜ Fail ⬜ PAT  Pass ⬜ Fail ⬜  Pass ⬜ Fail ⬜  Pass ⬜ Fail ⬜ Airflow test Recorded airflow 

Pass ⬜ Fail ⬜ ______________ 

Pass ⬜ Fail ⬜ ______________ 

Pass ⬜ Fail ⬜ ______________ 

HEPA replaced  Y ⬜ N ⬜  Y ⬜ N ⬜  Y ⬜ N ⬜ Any visual damage  Y ⬜ N ⬜  Y ⬜ N ⬜  Y ⬜ N ⬜ Parts replaced Description of new parts fitted 

Y ⬜ N ⬜  

  

______________ 

Y ⬜ N ⬜   

 ______________ 

Y ⬜ N ⬜   

 ______________ 

 

17 /17 