  • User Manual for DM800 ECDIS hardware

    Document Number 9301582 Version Number 1.1

    Date November 2012

  • User manual for DM800E ECDIS hardware Copyright Danelec Marine A/S

    9301582-11 Page 2/20

    Revision record Version Date Description 1.0 May 2010 Original issue of document 1.1 November 2012 Updated to reflect ECDIS software version 1.50

  • User manual for DM800E ECDIS hardware Copyright Danelec Marine A/S

    9301582-11 Page 3/20

    Contents

    REVISION RECORD ...........................................................................................................2

    1 SCOPE AND PURPOSE ..........................................................................................4 1.1 References................................................................................................................4 1.2 Terms and Abbreviations ..........................................................................................4

    2 SYSTEM OVERVIEW FOR DM800E........................................................................5 2.1 System overview.......................................................................................................5

    2.1.1 DPU (Data Processing unit) ...............................................................................6 2.1.2 DVD drive and External USB port ......................................................................6 2.1.3 eToken...............................................................................................................6 2.1.4 RPU (Radar processing unit) .............................................................................6 2.1.5 Alarm panel........................................................................................................6

    2.2 ECDIS cluster............................................................................................................7

    3 ALARM PANEL........................................................................................................8 3.1 Alarm volume ............................................................................................................8 3.2 ECDIS computer shut down......................................................................................8 3.3 ECDIS computer restart ............................................................................................8

    4 MONITOR .................................................................................................................9 4.1 Control panel on monitor...........................................................................................9 4.2 Control of Monitor......................................................................................................9

    5 SELF TEST.............................................................................................................10 5.1 Buzzer in alarm panel .............................................................................................10 5.2 Test of monitor ........................................................................................................10

    6 ECDIS DATA PROCESSING UNIT (DPU) .............................................................11 6.1 AC breaker..............................................................................................................11 6.2 Status LEDs ............................................................................................................12

    6.2.1 CPU status LED...............................................................................................12 6.2.2 FE status LED..................................................................................................12

    7 SYSTEM MANAGEMENT PANEL .........................................................................13 7.1 System Management Panel ....................................................................................14 7.2 Initialization of an eToken .......................................................................................15

    7.2.1 When to perform an eToken initialization.........................................................15 7.2.2 Performing an initialization of a new eToken....................................................15 7.2.3 Performing a reinitialization of an existing eToken...........................................17

    7.3 Dump for support ....................................................................................................19

  • User manual for DM800E ECDIS hardware Copyright Danelec Marine A/S

    9301582-11 Page 4/20

    1 Scope and purpose User manual for DM800E ECDIS

    1.1 References 9301584 User Manual for Dolphin ECDIS

    1.2 Terms and Abbreviations ECDIS Electronic Chart Display and Information System

  • User manual for DM800E ECDIS hardware Copyright Danelec Marine A/S

    9301582-11 Page 5/20

    2 System overview for DM800E

    2.1 System overview

    One ECDIS consists of the following parts:

    ECDIS DM800 DPU

    Display

    Keyboard

    DVD drive and External USB port

    Alarm panel

    RPU (optional)

    USB 5

    USB 6

    USB 7

    AP

    DVI

    eToken USB 8

    USB 2

    2 x IEC 61162-2

    10 x IEC 61162-1

    For sensors Radar

    4 x Ethernet To other ECDISs

    COM1

    USB port DVD drive

  • User manual for DM800E ECDIS hardware Copyright Danelec Marine A/S

    9301582-11 Page 6/20

    2.1.1 DPU (Data Processing unit) The data processing unit contains the computer for the ECDIS application and a communication front-end. The DPU is installed in the main cabinet. For more information consult section 6.

    2.1.2 DVD drive and External USB port The DVD drive and external USB port is installed in the main cabinet. These are used for updating charts and software. Notice, charts can be updated using the Internet.

    2.1.3 eToken The eToken contains the keys needed for enabling access to charts. The eTokens for one installation (i.e. vessel/cluster) shall be regarded as at set and must not be mixed with eTokens from another installation.

    2.1.4 RPU (Radar processing unit) The RPU is an optionally interface to the vessels radar. When installed, radar overlay on the charts can be displayed. The RPU is installed in the main cabinet.

    2.1.5 Alarm panel The ECDIS alarm panel is a small box that must be installed adjacent to the monitor. Consult section 3

  • User manual for DM800E ECDIS hardware Copyright Danelec Marine A/S

    9301582-11 Page 7/20

    2.2 ECDIS cluster A complete ECDIS installation will in most cases consist of a number of systems (a cluster). In order to ensure redundancy each ECDIS must be connected to two other systems if the cluster contains more than two systems.

    Cluster containing two ECDISs

    Cluster with three ECDISs

    1 2 1 2 1 2

    Backup Planning Master

    1 2 1 2

    Backup Master

  • User manual for DM800E ECDIS hardware Copyright Danelec Marine A/S

    9301582-11 Page 8/20

    3 Alarm panel

    The ECDIS alarm panel is a small box adjacent to the monitor.

    3.1 Alarm volume The ECDIS will generate an audible alarm following an error e.g. if the signal from the GPS is lost. The volume of the alarm signal may be adjusted pressing the buttons marked Alarm volume.

    3.2 ECDIS computer shut down Notice! The procedure described in this section is only applicable if the ECDIS application freezes or stops responding to user input. The normal procedure for closing the ECDIS application (i.e. setting the ECDIS standby) is to click on in the right top corner.

    Press the two reset buttons simultaneously for approximately 5 seconds in order to shut down the computer for the ECDIS application.

    3.3 ECDIS computer restart Press the two buttons simultaneously in order to restart the computer. This is applicable both after a hard shutdown (see section 3.2) or if the ECDIS is standby after the application is closed normally.

  • User manual for DM800E ECDIS hardware Copyright Danelec Marine A/S

    9301582-11 Page 9/20

    4 Monitor 4.1 Control panel on monitor Under normal operating conditions do not change the monitor settings except for brightness which is controlled by the adjusting knob. Please notice that the monitor is not calibrated unless the white line on the knob is facing up (12 oclock). The monitor can be reset to calibrated state (expect for brightness control) by reverting to factory settings (consult the manual for the monitor).

    4.2 Control of Monitor The color generating capability of the monitor may deteriorate over time. How the quality of the monitor is checked is described in p/n 9301584 User Manual for Dolphin ECDIS in the section named Color Differentiation Test.

  • User manual for DM800E ECDIS hardware Copyright Danelec Marine A/S

    9301582-11 Page 10/20

    5 Self test The presence of the DVD drive, keyboard, Trackball, eToken and optionally the RPU is checked by the DPU. An alarm will be generated if an error on one of these devices is detected.

    5.1 Buzzer in alarm panel The buzzer in the alarm panel may be checked by pressing volume up or down. The alarm will sound shortly at the current audio level if one of the buttons is pressed shortly.

    5.2 Test of monitor Check the colors and the contrast for the monitor (visual), if in doubt consult section 4.2.

  • User manual for DM800E ECDIS hardware Copyright Danelec Marine A/S

    9301582-11 Page 11/20

    6 ECDIS data processing unit (DPU) DPU front panel:

    6.1 AC breaker The ECDIS DPU is protected by electronic circuits and a resettable breaker. The breaker will pop out if one of the following events happens

    Over voltage Permanent under voltage Excessive input current Internal power supply failure

    It is safe to push the breaker in if popped out (if it pops out right away wait at least one minute before pushing it in aging)

  • User manual for DM800E ECDIS hardware Copyright Danelec Marine A/S

    9301582-11 Page 12/20

    6.2 Status LEDs

    6.2.1 CPU status LED Off: The computer for the ECDIS application is standby or without power. If the FE status LED is turned off then check the power breaker (must be pressed in). After this check the presence of power.

    Green (normal operation): The computer for the ECDIS application is powered on and is probably operating normally.

    Blue flash (normal operation): Disk activity.

    Green blinking (1Hz): Error on DVD drive, keyboard or Trackball.

    Red/yellow: The computer for the ECDIS application did not start.

    6.2.2 FE status LED Off: The AC power is not present or the AC breaker is disconnected (popped out).

    Green (normal operation): The FE is started and has detected that the computer for the ECDIS application is responding.

    Red: Booting (not ready). If the Red LED is turned on for more than 60 second, close the application normally. If this is not possible use the alarm panel (se section 3.2). After that, restart the ECDIS by switching the AC power off and on (operate the AC breaker next to the AC input plug).

    Blue: The computer for the ECDIS application is not responding. Switch the power off and then on (operate the AC breaker) if this condition remains for more that 6 minutes.

  • User manual for DM800E ECDIS hardware Copyright Danelec Marine A/S

    9301582-11 Page 13/20

    7 System Management Panel The ECDIS includes a System Management panel for performing special non standard tasks. Notice: The System Management Panel should be used only by personal with prober authorization, as incorrect use may result in loss of chart licenses.

    The System Management Panel is opened from ECDIS application. Move the cursor to the right bottom corner on the chart and this box will appear.

    Click on Config

    Select the system tab and click on System Management

    You will be prompted for a password The default password is: system manager

  • User manual for DM800E ECDIS hardware Copyright Danelec Marine A/S

    9301582-11 Page 14/20

    7.1 System Management Panel

    Notice: Double click on the icons to execute the programs. Reset Licenses: This is needed if a new eToken is installed, consult section 7.2 (Requires

    restart) Restart ECDIS (application) Change Password: Change the System Management password. Dump For Support: Create a Dump For Support file. This may be requested by the service

    technician in case of problems with the system. Please consult section 7.3 Restart: ECDIS computer restart - this will not affect the front-end. Shutdown: ECDIS computer shutdown - this will not affect the front-end.

    Use the [ X ] to close the panel.

  • User manual for DM800E ECDIS hardware Copyright Danelec Marine A/S

    9301582-11 Page 15/20

    7.2 Initialization of an eToken

    7.2.1 When to perform an eToken initialization An initialization is a pairing between the DPU and the eToken.

    Only one eToken can be initialized on a DPU at a time, so initializing an eToken automatically removes the initialization of a previous eToken.

    An initialization is always required if an eToken is replaced with another eToken, or if an eToken is moved to another DPU.

    An eToken can be initialized an unlimited number of times.

    Please notice, the ECDIS application will not accept sensor data unless an eToken has been initialized on the system.

    7.2.2 Performing an initialization of a new eToken Use this feature to initialize a new eToken and when replacing an existing eToken on a system.

    After double clicking Reset Licenses on the System Management Panel, the ECDIS will restart and after approximately 1 minute the following image may be shown (the image will be skipped if the attached eToken is not the currently initialized eToken).

    Click on No.

    Insert the new eToken for the ECDIS in USB port 8 on the DPU.

    Click on OK.

  • User manual for DM800E ECDIS hardware Copyright Danelec Marine A/S

    9301582-11 Page 16/20

    The system may install a driver depending on the type of eToken you have inserted. A driver installation involves several restarts.

    The system displays this message when finished:

    Click on Yes. (The driver is already installed).

    Click on Yes.

    Click on Yes.

    After a few second the eToken has been initialized.

  • User manual for DM800E ECDIS hardware Copyright Danelec Marine A/S

    9301582-11 Page 17/20

    Click on OK.

    Click on OK to restart the ECDIS and return to normal operation.

    7.2.3 Performing a reinitialization of an existing eToken Use this feature to reset the licenses for an already initialized eToken.

    Make sure the eToken is inserted in USB port 8 on the DPU.

    After double clicking Reset Licenses on the System Management Panel, the ECDIS will restart and after approximately 1 minute the following image will be shown:

    Click on Yes.

    Click on Yes. (The driver is already installed)

    Click on Yes.

  • User manual for DM800E ECDIS hardware Copyright Danelec Marine A/S

    9301582-11 Page 18/20

    Click on Yes.

    After a few second the eToken has been reinitialized.

    Click on OK.

    Click on OK to restart the ECDIS and return to normal operation.

  • User manual for DM800E ECDIS hardware Copyright Danelec Marine A/S

    9301582-11 Page 19/20

    7.3 Dump for support Utilize this feature if help for troubleshooting is needed.

    Insert a USB stick in the USB port adjacent to the DVD drive Click Browse and select the USB stick as destination i.e. typically drive E: Use the filename suggested by the program.

    Click on Save

    Click on Start dump

  • User manual for DM800E ECDIS hardware Copyright Danelec Marine A/S

    9301582-11 Page 20/20

    This window will open and the progress will be displayed

    Click on Close