8/8/2019 User Manual IUSB-9041WG
http://slidepdf.com/reader/full/user-manual-iusb-9041wg 1/37
Industrial USB Server User’s Manual
IUSB-9041WG
Version 1.1
July 2009.
ORing Industrial Networking Corp.
4F., NO.3, Lane235, Baociao Rd.Sindian City,
Taipei County 23145 Taiwan, R.O.C.
Tel: + 886 2 2918 3036
Fax: + 886 2 2918 3084
Website : www.oring-networking.com
E-mail : [email protected]
8/8/2019 User Manual IUSB-9041WG
http://slidepdf.com/reader/full/user-manual-iusb-9041wg 2/37
Table of ContentGETTING TO KNOW YOUR DEVICE SERVER............................................................................................... 1
1.1 About the IUSB-9041WG USB Server ........................................................... ................................... 1
1.2 Software Features ................................... .............................................................. ........................... 1
1.3 Hardware Features ........................................................ .............................................................. ..... 2
HARDWARE INSTALLATION ....................................................................................................................... 3
2.1 Installing IUSB-9041WG on DIN-Rail ...... .............................................................. ........................... 3
2.1.1 Mount IUSB-9041WG on DIN-Rail ............................................................................................................ 3
2.2 Wall Mounting Installation ........................................................ ......................................................... 4
2.2.1 Mount IUSB-9041WG on the wall .............................................................................................................. 5
HARDWARE OVERVIEW ............................................................................................................................ 8
3.1 Front Panel ................................................................... ............................................................... ..... 8
3.2 Bottom panel ....................................................... ................................................................. ............. 9
CABLES ................................................................................................................................................10
4.1 Ethernet Cables ....................................................................... ....................................................... 10
MANAGEMENT INTERFACE .....................................................................................................................12 5.1 USBIP Admin ...................................................................................... ............................................ 12
5.1.1 Install USBIP Admin ................................................................................................................................. 12
5.1.2 Using USBIP Admin .................... ...................... ...................... ...................... ..................... ...................... . 13
5.1.2.1 Mount USB Device ........................................................................................................................ 13
5.1.2.2 Search the IUSB-9041WG ............................................................................................................. 15
5.1.2.3 Device Mapping ............................................................................................................................. 18
5.1.2.4 Printer Auto-Connect ..................................................................................................................... 19
5.1.3 Server Manager.......................................................................................................................................... 20
5.1.3.2 Manage USB server ..................................................................................................................... 20
5.2 Configuration by Web Browser .................................................................................................... ... 23
5.2.1 Connect to the Web page ........................................................................................................................... 24
5.2.2 Date / Time ................................................................................................................................................ 25
5.2.3 Network Setting .................... ...................... ...................... ...................... ...................... ..................... ........ 25
5.2.4 Status ......................................................................................................................................................... 28
8/8/2019 User Manual IUSB-9041WG
http://slidepdf.com/reader/full/user-manual-iusb-9041wg 3/37
IUSB-9041WG User’s Manual
5.2.5 Upgrade Firmware .................... ...................... ...................... ..................... ...................... ..................... ..... 28
5.2.6 Notification ................................................................................................................................................ 30
5.2.7 LOG Page ................... ..................... ...................... ...................... ...................... ...................... .................. 31
TECHNICAL SPECIFICATIONS ..................................................................................................................32
8/8/2019 User Manual IUSB-9041WG
http://slidepdf.com/reader/full/user-manual-iusb-9041wg 4/37
IUSB-9041 User’s Manual
1 ORing Industrial Networking Corp.
Getting to Know Your Device Server
1.1 About the IUSB-9041WG USB Server
As far as we know, we can easily share a printer over a network. But
why can't we share all the rest of your USB devices just as easily?
IUSB-9041 is a revolutionary solution from Oring. You can easily
access any USB device connected to IUSB-9041WG from your
computer via a LAN or the Internet as if it was physically plugged into
your own PC USB. The USB server supports wide variety of USB
devices and can connect 4 USB2.0 devices at the same time.
User can conveniently manage IUSB-9041WG by USBIP Admin or web via LAN interface. It is
easy for you to install and configure USB server over the network by USBIP Admin.
1.2 Software Features
Allows working with remote USB device as with local ones.
Supports wide variety of USB devices.
Compatible with bulk, interrupt and isochronous type USB devices.
Supports printing to USB printer from Wired Interface.
Supports Printer Auto Connect while sharing the printer to different Client PC's.
Supports USB device safe removal.
User-Friendly Application interface.
8/8/2019 User Manual IUSB-9041WG
http://slidepdf.com/reader/full/user-manual-iusb-9041wg 5/37
8/8/2019 User Manual IUSB-9041WG
http://slidepdf.com/reader/full/user-manual-iusb-9041wg 6/37
IUSB-9041WG User’s Manual
3 ORing Industrial Networking Corp.
Hardware Installation
2.1 Installing IUSB-9041WG on DIN-RailEach IUSB-9041 has a DIN-Rail kit on rear panel. The DIN-Rail kit helps IUSB-9041 switch to
fix on the DIN-Rail. It is easy to install the IUSB-9041 on the DIN-Rail:
2.1.1 Mount IUSB-9041WG on DIN-RailStep 1: Slant the IUSB-9041 and mount the metal spring to DIN-Rail.
Figure 2-1
Metal Spring
8/8/2019 User Manual IUSB-9041WG
http://slidepdf.com/reader/full/user-manual-iusb-9041wg 7/37
IUSB-9041WG User’s Manual
ORing Industrial Networking Corp 4.
Step 2: Push the IUSB-9041WG toward the DIN-Rail until you heard a “click” sound.
Figure 2-2
2.2 Wall Mounting InstallationEach IUSB-9041WG has another installation method for users to fix the IUSB-9041WG. A
wall mount panel can be found in the package. The following steps show how to mount the
IUSB-9041WG on the wall.
8/8/2019 User Manual IUSB-9041WG
http://slidepdf.com/reader/full/user-manual-iusb-9041wg 8/37
IUSB-9041WG User’s Manual
5 ORing Industrial Networking Corp.
2.2.1 Mount IUSB-9041WG on the wall
Step 1: Remove DIN-Rail kit.
Figure 2-3
8/8/2019 User Manual IUSB-9041WG
http://slidepdf.com/reader/full/user-manual-iusb-9041wg 9/37
IUSB-9041WG User’s Manual
ORing Industrial Networking Corp 6.
Step 2: Use 6 screws that can be found in the package to combine the wall mount panel. Just like
the picture shows below:
Figure 2-4
The screws specification shows in the following two pictures. In order to prevent
IUSB-9041WG from any damage, the screws should not larger than the size that used in
IUSB-9041WG.
Pozidrive
Figure 2-5
8/8/2019 User Manual IUSB-9041WG
http://slidepdf.com/reader/full/user-manual-iusb-9041wg 10/37
IUSB-9041WG User’s Manual
7 ORing Industrial Networking Corp.
Step 3: Mount the combined IUSB-9041WG on the wall.
Figure 2-6
8/8/2019 User Manual IUSB-9041WG
http://slidepdf.com/reader/full/user-manual-iusb-9041wg 11/37
IUSB-9041WG User’s Manual
ORing Industrial Networking Corp 8.
Hardware Overview
3.1 Front Panel
Figure 3-1
1. Ready LED. Blinking when device is booting, and light on when device is ready to use.
2. LED for PWR1, PWR2 & PWR3. When the PWR is linked, the green led will be light on.
3. LED for USB. When USB device is connected, the green led will be light on.
4. LED for Ethernet ports status.
5. Reset Button. Press for 5 seconds for factory default.
6. LED for fault indicator. When fault occurred, this red LED will be light on.
7. USB port for USB device to connect.
1
2
3
4
5
6
7
8
8/8/2019 User Manual IUSB-9041WG
http://slidepdf.com/reader/full/user-manual-iusb-9041wg 12/37
IUSB-9041WG User’s Manual
9 ORing Industrial Networking Corp.
8. 10/100Base-T(X) Ethernet port.
3.2 Bottom panel
The bottom panel components of IUSB-9041WG are shown as below:
1. Terminal block includes: PWR1 (12~48V DC).
2. Relay output (1A@24VDC).
3. Terminal block includes: PWR2 (12~48V DC).
4. Power Jack include: PWR2 (12 ~ 48V DC).
5. Frame ground.
Figure 3-2
1 32 4 5
8/8/2019 User Manual IUSB-9041WG
http://slidepdf.com/reader/full/user-manual-iusb-9041wg 13/37
IUSB-9041WG User’s Manual
ORing Industrial Networking Corp 10.
Cables
4.1 Ethernet Cables
The IUSB-9041WG has standard Ethernet ports. According to the link type, the
IUSB-9041WG use CAT 3, 4, 5,5e UTP cables to connect to any other network device (PCs,
servers, switches, routers, or hubs). Please refer to the following table for cable
specifications.
Cable Type Max. Length Connector
10BASE-T Cat. 3, 4, 5 100-ohm UTP 100 m (328 ft) RJ-45
100BASE-TX Cat. 5 100-ohm UTP UTP 100 m (328 ft) RJ-45
Table 4-1 Cable Types and Specifications
100BASE-TX/10BASE-T Pin Assignments
With 100BASE-TX/10BASE-T cable, pins 1 and 2 are used for transmitting data, and pins 3
and 6 are used for receiving data.
8/8/2019 User Manual IUSB-9041WG
http://slidepdf.com/reader/full/user-manual-iusb-9041wg 14/37
IUSB-9041WG User’s Manual
11 ORing Industrial Networking Corp.
Pin Number Assignment
1 TD+
2 TD-
3 RD+
4 Not used
5 Not used
6 RD-
7 Not used
8 Not used
Table 4-2 RJ-45 Pin Assignments
The IUSB-9041WG supports auto MDI/MDI-X operation. You can use a straight- through
cable to connect PC to IUSB-9041WG. The following table below shows the 10BASE-T/
100BASE-TX MDI and MDI-X port pin outs.
Pin Number MDI port MDI-X port
1 TD+(transmit) RD+(receive)
2 TD-(transmit) RD-(receive)
3 RD+(receive) TD+(transmit)
4 Not used Not used
5 Not used Not used
6 RD-(receive) TD-(transmit)
7 Not used Not used
8 Not used Not used
Table 4-2 MDI / MDI-X pins assignment
Note: “ + ” and “ - ” signs represent the polarity of the wires that make up each wire pair.
8/8/2019 User Manual IUSB-9041WG
http://slidepdf.com/reader/full/user-manual-iusb-9041wg 15/37
IUSB-9041WG User’s Manual
ORing Industrial Networking Corp 12.
Management Interface
5.1 USBIP Admin
USBIP Admin is a powerful Windows utility for USB server. It supports server discovery, server
configuration and Device Mapping .it is easy for you to install and configure server over the
network.
5.1.1 Install USBIP Admin
Please run the setup program, Follow the instructions on screen to install the USB-Tool.exe.
After finishing Installing, Running USB-Tool.exe, it will be shown as below.
USBIP
Admin
8/8/2019 User Manual IUSB-9041WG
http://slidepdf.com/reader/full/user-manual-iusb-9041wg 16/37
IUSB-9041WG User’s Manual
13 ORing Industrial Networking Corp.
5.1.2 Using USBIP Admin
5.1.2.1 Mount USB Device
In this section, you will learn how to use your USB devices via the USB Server.
Step 1 Connecting Your USB Device to the USB Server
Figure 5-1
Before using USB Server, connect your USB device to any of the USB port on the
USB Server.
Step 2 Mount your USB device to the USB server.
Right-click the USB device, choose “connect”, the USB device will be mounted to the
local PC, then you can access this device freely as if it was physically plugged into
your own PC USB
Plug in USB devices
8/8/2019 User Manual IUSB-9041WG
http://slidepdf.com/reader/full/user-manual-iusb-9041wg 17/37
IUSB-9041WG User’s Manual
ORing Industrial Networking Corp 14.
Figure 5-2 Note : Any device is to be disconnected or unplugged only after proper closure of related Applications.
Connect Disconnect
8/8/2019 User Manual IUSB-9041WG
http://slidepdf.com/reader/full/user-manual-iusb-9041wg 18/37
IUSB-9041WG User’s Manual
15 ORing Industrial Networking Corp.
5.1.2.2 Search the IUSB-9041WG
Step 1 Search servers over Network. You can scan all server or scan specify server.
The list will show all the USB server devices over the Network. (Default IP:
192.168.10.2)
Figure 5-3
8/8/2019 User Manual IUSB-9041WG
http://slidepdf.com/reader/full/user-manual-iusb-9041wg 19/37
IUSB-9041WG User’s Manual
ORing Industrial Networking Corp 16.
It also allows user to search the device by enter the MAC of the
IUSB-9041WG.After the tool gets the device, go to the next step to set the IP
of IUSB-9041WG.
Figure 5-4
8/8/2019 User Manual IUSB-9041WG
http://slidepdf.com/reader/full/user-manual-iusb-9041wg 20/37
IUSB-9041WG User’s Manual
17 ORing Industrial Networking Corp.
Step 3 After the device is set & updated, it will be added into the list.
Figure 5-5
Figure 5-6
8/8/2019 User Manual IUSB-9041WG
http://slidepdf.com/reader/full/user-manual-iusb-9041wg 21/37
IUSB-9041WG User’s Manual
ORing Industrial Networking Corp 18.
5.1.2.3 Device Mapping
To start mapping/unmapping the device on IUSB-9041WG, please go to “Device
Mapping” and click on the “Start Mapping device” or “Stop Mapping Device”
Figure 5-7
8/8/2019 User Manual IUSB-9041WG
http://slidepdf.com/reader/full/user-manual-iusb-9041wg 22/37
IUSB-9041WG User’s Manual
19 ORing Industrial Networking Corp.
5.1.2.4 Printer Auto-Connect
USBIP Admin Utility enables Printers be shared between multiple clients making it a
bidirectional Print Server.
In order to share the printer between multiple clients, user may need to connect the
printer at least once to install the driver for the Printer.
Once the printer is enumerated, disconnect the Printer form the Device Mapping
Window; Select the Printer Auto Connect button on the menu bar to open
the Printer Auto-Connect Window. This can also be done from “Device Mapping”
window.
Figure 5-8
8/8/2019 User Manual IUSB-9041WG
http://slidepdf.com/reader/full/user-manual-iusb-9041wg 23/37
8/8/2019 User Manual IUSB-9041WG
http://slidepdf.com/reader/full/user-manual-iusb-9041wg 24/37
IUSB-9041WG User’s Manual
21 ORing Industrial Networking Corp.
Basic setting
You can set any name that you like for USB server. USB server Default Name is
“IUSB-9041WG”.
Figure 5-10
IP setting
You must assign a valid IP address for USB Server before attached in your network
environment. You can configure the Static IP manually or set DHCP mode to
automatically obtain an IP address from DHCP server. The Factory Default IP
address is “192.168.10.2”
8/8/2019 User Manual IUSB-9041WG
http://slidepdf.com/reader/full/user-manual-iusb-9041wg 25/37
IUSB-9041WG User’s Manual
ORing Industrial Networking Corp 22.
Figure 5-10
Password
You can set up the password to prevent unauthorized access from your
server. Factory default is “admin”
Figure 5-11
8/8/2019 User Manual IUSB-9041WG
http://slidepdf.com/reader/full/user-manual-iusb-9041wg 26/37
IUSB-9041WG User’s Manual
23 ORing Industrial Networking Corp.
Restore Factory Default
Right- click on the USB Server in the list and select the” Restore Factory
Defaults” function to Restore all the USB server configuration to Default
settings.
Figure 5-12
5.2 Configuration by Web Browser
Users can easily manage USB Server by Sever WEB Page. The web interface has a home
page and four configuration pages, include Home page, Network Page, Status Page, Upgrade
Firmware Page and LOG Page.
8/8/2019 User Manual IUSB-9041WG
http://slidepdf.com/reader/full/user-manual-iusb-9041wg 27/37
IUSB-9041WG User’s Manual
ORing Industrial Networking Corp 24.
5.2.1 CONNECT TO THE WEB PAGE
Input the IP address of USB server with “https://192.168.10.2” in the URL of the browser,
then home page will be shown as below. The home page main displays the current network
settings, Server name, Firmware version and the USB server Feature.
Figure 5-13
8/8/2019 User Manual IUSB-9041WG
http://slidepdf.com/reader/full/user-manual-iusb-9041wg 28/37
IUSB-9041WG User’s Manual
25 ORing Industrial Networking Corp.
5.2.2 DATE / TIME
Date and Time can be set from this page. By enabling the NTP allow the
device to get the date / time from NTP server when the IUSB-9041WG started
up.
Figure 5-14
5.2.3 NETWORK
SETTING
You must assign a valid IP address for USB Server before attached in your network
environment. You can configure the Static IP manually or set DHCP mode to
automatically obtain an IP address from DHCP server. The Factory Default IP
address is “192.168.10.2”
8/8/2019 User Manual IUSB-9041WG
http://slidepdf.com/reader/full/user-manual-iusb-9041wg 29/37
IUSB-9041WG User’s Manual
ORing Industrial Networking Corp 26.
Figure 5-15
Wireless setting
Wireless Network type includes two modes: INFRA and ADHOC. The INFRA
type connects the network by wireless access point, but the ADHOC is formed
by the association of wireless and mobile devices capable of communicating
among themselves even when there is no networking INFRA structure
available.
8/8/2019 User Manual IUSB-9041WG
http://slidepdf.com/reader/full/user-manual-iusb-9041wg 30/37
IUSB-9041WG User’s Manual
27 ORing Industrial Networking Corp.
Figure 5-16
The following table describes the labels in this screen.
Label Description
Network Type Type includes INFRA and ADHOC.
SSID
Service Set Identifier Default is the default setting. The SSID is a unique name that
identifies a network. All devices on a network must share the same SSID name in order to
communicate on the network.
ChannelAll devices on the network must be set to the same channel to communicate on the network.
You can select the Auto.
NO Encryption You can set no encryption mode, but this mode is insecurity and don’t suggest use.
WEP You can set four encryption 5characters (WEP64), 13 characters (WEP128), 10 digits(WEP64), 26digits (WEP128).
TKIP TKIP (Temporal Key Integrity Protocol) is a key management protocol.
AESAES (Advanced Encryption System) is a variable bit length symmetric digital encryption
algorithm.
Table 5-3 Wireless Network setting
*Simply unplug the RJ-45 to change into wireless connection
8/8/2019 User Manual IUSB-9041WG
http://slidepdf.com/reader/full/user-manual-iusb-9041wg 31/37
IUSB-9041WG User’s Manual
ORing Industrial Networking Corp 28.
5.2.4 STATUS
The status page displays the current status of the USB devices attached.
The Device Status table shows the Vendor Id, Product Id, Product Name, and
Manufacturer name, USB Speed, client IP, client PC name, Duration.
Figure 5-17
5.2.5 UPGRADE FIRMWARE
You can upgrade Firmware by http ,click “Browse” and Choose the firmware path,
then click ”Http Upgrade” .
8/8/2019 User Manual IUSB-9041WG
http://slidepdf.com/reader/full/user-manual-iusb-9041wg 32/37
IUSB-9041WG User’s Manual
29 ORing Industrial Networking Corp.
Figure 5-18
8/8/2019 User Manual IUSB-9041WG
http://slidepdf.com/reader/full/user-manual-iusb-9041wg 33/37
IUSB-9041WG User’s Manual
ORing Industrial Networking Corp 30.
Important Note: It will take about 6 to 7 minutes to upgrade the Firmware. Please don’t power-off
the Power or remove the network cable during the Firmware Upgrade. The USB server will auto reboot
after the firmware grade is completed.
5.2.6 NOTIFICATION Specify the events that should be notified to the administrator. The events can be
alarmed by E-mail, system log or LED / Relay.
Figure 5-19
8/8/2019 User Manual IUSB-9041WG
http://slidepdf.com/reader/full/user-manual-iusb-9041wg 34/37
IUSB-9041WG User’s Manual
31 ORing Industrial Networking Corp.
5.2.7 LOG PAGE This Page will show the Event Log Information in detail after Event Happen.
The Log table shows the time, Event, USB device, client IP, client PC, Name.
Figure 5-20
8/8/2019 User Manual IUSB-9041WG
http://slidepdf.com/reader/full/user-manual-iusb-9041wg 35/37
IUSB-9041WG User’s Manual
ORing Industrial Networking Corp 32.
Technical Specifications
Network Interface
Ethernet 10/100Base-T(X)
Protocols IP, TCP, UDP, DHCP, BOOTP, ARP/RARP, DNS, SNMP, HTTP
WLAN Feature
Operating Mode Client mode
Antenna Connector Reverse SMA
Radio Frequency Type DSSS, OFDM
ModulationIEEE802.11b: CCK, DQPSK, DBPSK
IEEE802.11g: OFDM with BPSK, QPSK, 16QAM, 64QAM
Frequency Band
America/FCC: 2.412~2.462 GHz (11 channels)
Europe CE/ETSI: 2.412~2.472 GHz (13 channels)
Transmission RateIEEE802.11b: 1/ 2/ 5.5/ 11 Mbps
IEEE802.11g: 6/ 9/ 12/ 18/ 24/ 36/ 48/ 54 Mbps
Transmit Power IEEE802.11b/g: 16dBm
Encryption
Security
WEP: (64-bit ,128-bit key supported)
WPA/WPA2 :802.11i(WEP and AES encryption)
PSK (256-bit key pre-shared key supported) 802.1X and Radius
supported TKIP encryption
Wireless Security SSID broadcast disable
LED Indicators
LED Indicators
PWR1, PWR 2 , PWR 3
1) Green On: Power is on and functioning normally.
Ready
1) Green On: Device is ready to use.
USB Port LED:
1) Green On: USB device connected.
8/8/2019 User Manual IUSB-9041WG
http://slidepdf.com/reader/full/user-manual-iusb-9041wg 36/37
IUSB-9041WG User’s Manual
33 ORing Industrial Networking Corp.
Fault Relay
1) Amber On: Fault Alarm
Power Requirements
Power InputPWR1, 2: 12 ~ 48VDC 3-pin in Terminal Block
PWR3: 12 ~ 48VDC in power jack
Reverse Polarity Protection Present at terminal block
Power Consumption 4 Watts MAX
Software Utility
Utility
USB-Tool for Windows NT/2000/XP/ 2003/VISTA/Windows
7(32/64 bit) which include
Device discovery
ConfigurationWeb HTTP, USB-Tool for Windows NT/2000/XP/VISTA/Windows
7(32/64 bit)
Environmental
Operating Temperature -10 to 60°C (14 to 140°F)
Operating Humidity 5% to 95%(Non-condensing)
Storage Temperature -40 to 85°C (-40 to 185°F)
Mechanical
Dimensions(W x D x H) 26mm(W)x95mm(D)x144mm(H)
Casing IP-30 protection
Regulatory Approvals
Shock IEC 60068-2-27
Free Fall IEC 60068-2-32
Vibration IEC 60068-2-6
EMI FCC Part 15, CISPR (EN55022) class A
EMS
EN61000-4-2 (ESD), EN61000-4-3 (RS)
EN61000-4-4 (EFT)
EN61000-4-5 (Surge)
8/8/2019 User Manual IUSB-9041WG
http://slidepdf.com/reader/full/user-manual-iusb-9041wg 37/37
IUSB-9041WG User’s Manual
ORing Industrial Networking Corp 34
EN61000-4-6 (CS)
Warranty 5 years