User Manual V2.4
Omniksol WIFIKIT User Manual
Omnik New Energy Co., Ltd.
User Manual V2.4
Overview of WIFIKIT Function
Omniksol-WIFIKIT is developed by Omnik as an external communication monitoring device,
which integrates WiFi device for users and provides a wireless monitor function.
By connecting with inverters through RS485 interface, the Kit can receive information from
inverters and realize cascade of inverters. One side It provides wireless function, another
side, it may also use cable to transfer inverter data to the web server.
Users can monitor the runtime status of the device by checking the 4 LEDs on the panel
which indicates Power, RS485, Link and Status respectively.
User Manual V2.4
1
Catalog
1 RS485 Card Install SOP ............................................................................................................................................... 2
1.1 Disassembly ......................................................................................................................................................... 2
1.2 Installation ............................................................................................................................................................ 3
2 Omniksol WIFIKIT User Manual ................................................................................................................................. 5
2.1 Unpack ................................................................................................................................................................. 5
2.2 The installation of data collector ........................................................................................................................... 5
2.2.1 Wall-mounted installation .................................................................................................................................. 5
2.2.2 Horizontal data collector installation .................................................................................................................. 5
2.3 Connection between data collector and inverter ................................................................................................... 6
2.3.1 The instructions of data collector interface and connection line interface ......................................................... 6
2.3.2 Steps of connection .......................................................................................................................................... 7
2.4 WiFi settings ......................................................................................................................................................... 8
2.4.1 Wireless network ............................................................................................................................................... 8
2.4.2 Wired network ................................................................................................................................................. 12
2.5 Debug ................................................................................................................................................................. 13
2.6 Register on monitoring website .......................................................................................................................... 15
2.6.1 Click Register button to go to registering interface for new account ........................................................... 16
2.6.2 Fill in users information as required ........................................................................................................... 16
2.7 Login the PV monitoring system to manage the power station ........................................................................... 18
2.8 IPhone & iPad application................................................................................................................................... 23
3 Contact ....................................................................................................................................................................... 25
User Manual V2.4
2
1 RS485 Card Install SOP
1.1 Disassembly
Picture 1.1.1
Unscrew the four screws on the interface panel with the screwdriver as shown in Picture
1.1.1 and keep the screws aside.
Picture 1.1.2
User Manual V2.4
3
Picture 1.1.3
Unscrew the two-holed water-proofing connector from the interface panel as shown in
Picture 1.1.2, 1.1.3.
1.2 Installation
Pick out the net cable and the water-proofing connector from the package and follow the
Picture
A. Put the net cable in from the gap
B. Pput the net cable one after another into the kneck of the interface panel
Picture 1.2.1
User Manual V2.4
4
C. Insert the RS485 card lightly from the position as follow picture
Picture 1.2.2
D. Finish the installation, as Picture 1.2.3
Picture 1.2.3
User Manual V2.4
5
2 mniksol WIFIKIT User Manual
2.1 Unpack
After unpacking the box, please check the parts according to the below list. Contact the
manufacturer immediately, should you find any damage, missing or wrong model of the
device or any parts.
Serial Name Quantity Model
A PV data collector 1 WIFIKIT
B Power supply adapter 1 FY0502000
C screw 2 --
D expanded rubber tube 2 --
E manual 1 --
2.2 The installation of data collector
2.2.1 Wall-mounted installation
1. Mark two horizontal round holes which distance is 69mm in the selected position
2. Drill two 6mm holes in the marked position, the depth of the hole is not less than 30mm
3. Punch the expanded rubber tubes into the holes lightly with a rubber hammer
4. Wring two screws into the expanded rubber tubes, the screws head exposed wall about
6cm
5. Hang the PV data collector WIFIKIT on the screwshold the metal part of the antenna and rotate the antenna to a wanted position
Picture 2.2.1
2.2.2 Horizontal data collector installation
Lay the data collector on a flat surface
Note1: The protection level of PV data collector WIFIKIT is IP21. It cannot be installed outdoors or in the
Picture 2.1.1
User Manual V2.4
6
conditions of damp, dusty or with corrosive steam. Direct sunlight is also avoided, as well as shock and
pressure defense. In addition, as metal components have effect on the wireless signals, the antenna of
PV data collector (in all direction) should be away from metal components at least 10cm.
Note2: When screw or adjusting the antenna position, please note only the metal part can be screwed,
plastic part cannot be screwed, or the antenna will be damaged. in addition, the unusual installation status
will affect the usage of data collector, more details please refer to the abnormal condition and dispose
during debugging.
2.3 Connection between data collector and inverter
2.3.1 The instructions of data collector interface and connection line interface
Serial Instructions
A RS485/422 interface
B Ethernet
C Reset
D Power supply adapter interface
E Antenna interface
Picture 2.3.1
User Manual V2.4
7
2.3.2 Steps of connection
Both ends of the connecting wire are RJ45 network cable connectorall the line sequence
are T568B.
A. Single inverter connection
1. cut of the power supply of the inverter
2. Insert the network cable into anyone RJ45 port on anyone inverter
3. Let the other network cable connects the network interface of PV data collector
WIFIKIT
4. Connect the power supply adapter to data collector, then insert into the socket
B. Multiple inverter connection
1. Cut of the power supply of the inverter
Pin NO. RS485 RS422
1 NC NC
2 NC NC
3 NC RX+
4 A TX+
5 B TX-
6 NC RX-
7 GND GND
8 GND GND
Line sequence of
T568B
1. orange with white
2. orange
3. green with white
4. blue
5. blue white white
6. green
7. brown with white
8. brown
RJ45 crystal head
Picture 2.3.2
User Manual V2.4
8
2. Insert the network cable into anyone RJ45 port on anyone inverter
3. Insert the other network cable into anyone RJ45 port on second inverter
4. Make the needed monitoring inverters in series in the same way
5. Connect the PV data collector WIFIKIT to a inverter with the bus,constitute serial LAN
6. Connect the power supply adapter to data collector, then insert into the socket
Picture 2.3.3
Note: Must cut off the power supply before connection. Please make sure that all the connections are
completed, and then power the inverters and PV data collectors. Otherwise may cause personal injury or
equipment damage.
2.4 WiFi settings
2.4.1 Wireless Network
Insert the wifi part, turn on
DC power, 3minutes later
continue the next part
User Manual V2.4
9
Choose My network place click right hand button
Left click
User Manual V2.4
10
Choose WiFi Left Double Click
Enter 10.10.100.254 in your browser
Connect successfully
User Manual V2.4
11
Fill in the user name adminand passwordadmin
Left button Search
Choose your
regional WiFi and
click Apply
If your WiFi has a password,
click confirm
User Manual V2.4
12
Picture 2.4.1
Note: this default setting is router DHCP is on, if you can not connect to the network, please check if you
open the DHCP function.
2.4.2 Wired network
As the picture 2.4.2, you can use network cable to connect to the Ethernet port of WIFIKIT
and the port of router. Then the inverter info received by WiFi will be directly transferred to
the remote server.
Note: the default WIFIKIT is WiFi network, if use the Ethernet port, please restore to the factory default
status.
Do not fill in
Fill in the password of your wifi
Whether display your password DisableorEnable Enablesuggested
Left buttonApply
User Manual V2.4
13
Picture 2.4.2
2.5 Debug
LED indicating lamp Introductions
Picture 2.5.1
User Manual V2.4
14
Trouble shootings with LEDs
phenomenon
Possible reasons
Dealing ways
PO
WE
R
485
/42
2
LIN
K
ST
AT
US
Dark Dark Dark Dark Havent connected to
the power
Connect power and
ensure that the power
supply is good.
Light Dark X X The connection of
inverter is abnormal
Check the connection
cable is right and ensure
that the order is according
to 568-B
Ensure the stability of
RJ-45 connector line
Confirm the status of
Name of LED Status Description of status
POWER Light The power is normal
Dark The power is abnormal
485\422
Light The connection between collector and inverter is normal
Flashing Data is transferring between collector and inverter
Dark The connection between collector and inverter is abnormal
STATUS Dark LINK Flashing Connecting WiFi
STATUS Light
LINK Flashing Data is transferring of WiFi
LINK Light The connection of collector is normal
LINK Dark The connection of collector is abnormal
STATUS Flashing
LINK Flashing Data is transferring of port
LINK Light WiFi is in the AP way a terminal is connecting with the
equipment LINK Dark WiFi is in the AP way no terminal is connecting with the
equipment
User Manual V2.4
15
inverter and ensure its
working condition is
normal
Light X X Flashing In the AP Mode Set network settings
Light X Flashin
g Dark
Collector is not
connected with WIFI
Confirm if the antenna is
loose or fall off. If so, please
screw it.
Check if the WIFI wanted
is covered.
Restore the factory
settings according to the
installation manual and
reset.
Light Light Dark Light Fail to connect the
remote server
Please confirm that WIFI
can be connected with the
Internet.
Light Dark Dark Dark The system is initialized
Please wait. If there is no
change in 2min, please
reset the collector.
Note1:x means the status is instability
Note 2: when screw or adjusting the antenna position, please note only the metal part can
be screwed, plastic part cannot be screwed, or the antenna will be damaged
Note3: If the equipment still cannot work according to the above instructions, please
connect your device customer service.
2.6 Register on monitoring website
Our products supported by PV monitoring system Web site browserIE8FirefoxChromesafarilog into the website http://www.omnikportal.com, Click on register, enter the user registration page, follow the requirements for registration, after successful registration, enter
the mailbox and activity the account, then complete the registration.
User Manual V2.4
16
2.6.1 Click Register button to go to registering interface for new account
2.6.2 Fill in users information as required
Picture 2.6.2
Click and enter the
register interface
Picture 2.6.1
chooseOwner
Click and enter the configure
interface
Remarks: please read the carefully, the enclosure is
the cost list for all the countries, please choose your operators
Owner means the final user
* you must fill it
User Manual V2.4
17
Owner Account
Picture 2.6.3
Click and choose the
aim pic
ClickOKsave the pic
Fill in WiFi cards S/N code, see pic 2.6.4
Click the map, choose the
installation site
Select, and choose it to be the share mode,
other user can see
Finish the
register
User Manual V2.4
18
Picture 2.6.4
2.7 Login the PV monitoring system to manage the power station
After the successful register and account activationopen the login interface as below picture 2.7.1, input the correct email and code and enter the PV monitoring system, then you
can monitor and manage the power station.
Picture 2.7.1
Input the
correct email
and code
User Manual V2.4
19
Owner User Interface
Picture 2.7.2
Power station list
Choose your station and enter
Edit or delete the case
Not yet open Back to 2.7.2
interface
Enter the sharing case Enter the configure company account
interface
Add one case under your accountsame as 2.7.3
Picture 2.7.3 List of power stations
Picture 7-4 Navigation Bar
Reset password
User Manual V2.4
20
Picture 2.7.5 Main interface of power station
Change case
Case info search
Power station info
Energy saving
Real-time power and generated energy
switchover Print current
figure
User Manual V2.4
21
Picture 2.7.6 Real Time Interface
Internal temperature
Latest data collecting time
Picture 2.7.7 History Interface
Parameter
options
Choose the aim
inverter
User Manual V2.4
22
Picture 2.7.8 Alert Interfaces
Click , turn to picture 2.7.7
Picture 2.7.9 System Setting Interface
The interface same as
picture 2.7.3
User Manual V2.4
23
2.8 IPhone & iPad application
After registration of the power station, you can input the key words: Omniksolar, inverter, PV,
energy ,plant, monitor at the app store, then you can download the Omnik solar (iPhone) and
Omnik Solar HD(iPad) at app store.
After the download input your user name and password, then visit your station,(we supply a
free demo, for the users who do not register)choose the power station and enter the main
interface, then you the daily energy etc. will be displayed. Meanwhile, you can view the
relevant date to view the curve as below:
Picture 2.7.10 System Setting Interface
User Manual V2.4
24
Picture 2.8.1
1. Log in interface
2. Power station list interface
3. Main interface
4. Daytime curve interface
User Manual V2.4
25
3 Contact
If you have any technical problems about our productsplease contact usyou should
confirm the follow things before contact us:
Device model
Data collector serial number
The number of connected inverter
Add: Xinghu Road No.218 bioBAY Park C2, Suzhou China
Zip code215213
Fax: +86 512 6295 6682
Tel: +86 512 6295 6676
Mail: [email protected]