HECHUAN FX2N-32MR HECHUAN FX2N-32MR HCFA CORPORATION LIMITED User's manual Thanks for purchasing HCFA HMI products! Our hard working, your better life! series(HMI) Port Port Port Notes: For communication protocol, refer to section 1-1 for more details. For communication parameter, refer to section 1-3 for more details. Make sure COM2 communication port and attached cable TP13-PLC-R4-8P-3M are used in HCFA HC/LC series. Communication type is set to RS422 in the software. 1-1 Serial communication port Series UPU Link port Communication protocol Parameter setting Series Refer to section1-3-1 Refer to section1-3-2 Refer to section1-3-1 Refer to section1-3-1 Refer to section1-3-2 Refer to section1-3-1 Refer to section1-3-1 Refer to section1-3-2 Refer to section1-3-1 Refer to section1-3-1 Refer to section1-3-2 Refer to section1-3-1 Refer to section1-3-1 Refer to section1-3-2 Refer to section1-3-1 Refer to section1-3-3 Dedicated Protocol(Multi-Station) Dedicated Protocol(Multi-Station) Dedicated Protocol(Multi-Station) Dedicated Protocol(Multi-Station) Dedicated Protocol(Multi-Station) 1-2 Serial port parameter and cable fabrication Series Series UPC Link port COOM Type Parameter Cable Refer to section 1-5 Refer to section 1-5 Refer to section 1-5 Refer to section 1-5 Refer to section 1-5 Refer to section 1-5 Refer to section 1-5 Refer to section 1-5 Refer to section 1-5 Refer to section 1-5 Refer to section 1-5 Updated HCFA PLC Model name 1-3 Communication Setting 1-3-1 When Using HCFA HCA1, HCA2, HCA5, HCA6, HCA8 Communication Protocols HMI Settings HMI default communication parameters: 9600bps (Baud Rate), 7 (Data Bit), even (Parity Check), 1 (Stop Bit) and 0 (PLC Station No.) The PLC Communication Time Out, Max interval of word (bit) block pack, Max size of word(bit) block package on the right of the dialog box vary with PLC protocols. Generally the defaults are selected. RS422 Communication RS232 Communication PLC Settings The PLC setting is as shown below when HCFA HCA1, HCA2, HCA5, HCA6, HCA8 communication protocols are used: 1. Double-click the [PLC Parameter] under [Project Data List] in TP-Software 2. Open the [TX Parameter] dialog box. 3. Click the [Default] button to make settings without checking the [Communication Setting]: Note: 1 The communication protocols such as HCFA HCA1, HCA2, HCA5, HCA6, and HCA8 etc. can be selected according to PLC model if the Station No. is not used when the communication is realized through the communication function expansion board.' 2 Make sure the value of communication format D8120 is 0 when the communication is realized through the communication function expansion board. 1-3-2 When Using 'Dedicated protocol (Multi-station)' Communication Protocols HMI Settings HMI default communication parameters: 19200bps (Baud Rate), 7(Data Bit), even (Parity Check), 2 (Stop Bit) and 0 (PLC Station No.) Note: The protocols are only applicable to PLCs communicating through communication function expansion board and support Multiple Station No. and Baud Rate settings RS422 Communication RS232 Communication PLC Settings The PLC setting is as shown below when 'Dedicated protocol (Multi-station)' communication protocols are used. 1. Double-click the [PLC Parameter] under [Project Data List] on the left of TP-Software. 2. Open the [TX Parameter] dialog box. 3. Parameters for HCA1, HCA2 and HCA5 are shown below. Check the [Operate communication setting] option Note :1 Set the parameters as follows. The [Dedicated Protocol] is selected for Protocol, the [Sum Check] is checked, and [Form4] is selected for the Transmission Control Sequence. 4. Parameters for HCA8 are shown below. Check the [Operate communication setting] option. Note: 1 The [CH1] should be selected for HCA8 Series PLC. 2 Set the parameters as follows. [Dedicated Protocol] is selected for Protocol, [Sum Check] is checked, and [Form4] is selected for the Transmission Control Sequence. Aside from using [HC Parameter], the user can use the special data register D8120 in PLC to set the communication parameters for PLC. Special Data Registers Descriptions D8120 D8121 D8129 Applicable to HCA8 and other HC Series PLCs using CH1 Communication format Station No. setting Data network out-time counting * For example: If the PLC communication parameters are: 9600bps (Baud Rate), 7 (Data Bit), even (Parity Check), 2 (Stop Bit), 1(PLC Station No.), RS485 (Communication Method) and 1) (PLC Communication Time Out), then D8120=0xE08E, D8121=1, and D8129=1. Note: The settings will be valid when the PLC is restarted after the D8120 setting is modified. 1-3-3 When Using HCFA HCA4 Communication Protocols HMI Settings HMI default communication parameters: 19200bps (Baud Rate), 7(Data Bit), even (Parity Check), 2 (Stop Bit) and 0 (PLC Station No.) Rs422 Communication PLC Settings Double click [Setting] in the [Working list] of LC-Develpoer. Click the built-in RS422C port Before After
Transcript
  • HECHUANFX2N-32MR

    HECHUANFX2N-32MR

    HCFA CORPORATION LIMITED

    User's manual

    Thanks for purchasing HCFA HMI products!

    Our hard working, your better life!

    series(HMI)

    Port

    Port

    Port

    Notes:For communication protocol, refer to section 1-1 for more details.For communication parameter, refer to section 1-3 for more details.

    Make sure COM2 communication port and attached cable

    TP13-PLC-R4-8P-3M are used in HCFA HC/LC series.

    Communication type is set to RS422 in the software.

    1-1 Serial communication port

    Series UPU Link port Communication protocolParameter setting

    Series

    Refer to section 1-3-1

    Refer to section 1-3-2

    Refer to section 1-3-1

    Refer to section 1-3-1

    Refer to section 1-3-2

    Refer to section 1-3-1

    Refer to section 1-3-1

    Refer to section 1-3-2

    Refer to section 1-3-1

    Refer to section 1-3-1

    Refer to section 1-3-2

    Refer to section 1-3-1

    Refer to section 1-3-1

    Refer to section 1-3-2

    Refer to section 1-3-1

    Refer to section 1-3-3

    Dedicated Protocol(Mult i-Stat ion)

    Dedicated Protocol(Mult i-Stat ion)

    Dedicated Protocol(Mult i-Stat ion)

    Dedicated Protocol(Mult i-Stat ion)

    Dedicated Protocol(Mult i-Stat ion)

    1-2 Serial port parameter and cable fabrication

    Series

    Series UPC Link port COOM Type Parameter Cable

    Refer to section 1-5

    Refer to section 1-5

    Refer to section 1-5

    Refer to section 1-5

    Refer to section 1-5

    Refer to section 1-5

    Refer to section 1-5

    Refer to section 1-5

    Refer to section 1-5

    Refer to section 1-5

    Refer to section 1-5

    Updated HCFA PLC Model name

    1-3 Communication Setting

    1-3-1 When Using HCFA HCA1, HCA2, HCA5, HCA6, HCA8 Communication Protocols

    HMI SettingsHMI default communication parameters: 9600bps (Baud Rate), 7 (Data Bit), even (Parity Check), 1 (Stop Bit) and 0 (PLC Station No.)The PLC Communication Time Out, Max interval of word (bit) block pack, Max size of word(bit) block package on the right of the dialog box vary with PLC protocols. Generally the defaults are selected.

    RS422 Communication

    RS232 Communication

    PLC SettingsThe PLC setting is as shown below when HCFA HCA1, HCA2, HCA5, HCA6, HCA8 communication protocols are used:1. Double-click the [PLC Parameter] under [Project Data List] in TP-Software

    2. Open the [TX Parameter] dialog box.

    3. Click the [Default] button to make settings without checking the [Communication Setting]:

    Note: 1 The communication protocols such as HCFA HCA1, HCA2, HCA5, HCA6, and HCA8 etc. can be selected according to PLC model if the Station No. is not used when the communication is realized through the communication function expansion board.' 2 Make sure the value of communication format D8120 is 0 when the communication is realized through the communication function expansion board.

    1-3-2 When Using 'Dedicated protocol (Multi-station)' Communication Protocols

    HMI SettingsHMI default communication parameters: 19200bps (Baud Rate), 7(Data Bit), even (Parity Check), 2 (Stop Bit) and 0 (PLC Station No.)Note: The protocols are only applicable to PLCs communicating through communication function expansion board and support Multiple Station No. and Baud Rate settings

    RS422 Communication

    RS232 Communication

    PLC SettingsThe PLC setting is as shown below when 'Dedicated protocol (Multi-station)' communication protocols are used.1. Double-click the [PLC Parameter] under [Project Data List] on the left of TP-Software.

    2. Open the [TX Parameter] dialog box.

    3. Parameters for HCA1, HCA2 and HCA5 are shown below.

    Check the [Operate communication setting] optionNote :1 Set the parameters as follows.The [Dedicated Protocol] is selected for Protocol, the [Sum Check] is checked, and [Form4] is selected for the Transmission Control Sequence.

    4. Parameters for HCA8 are shown below.

    Check the [Operate communication setting] option.Note: 1 The [CH1] should be selected for HCA8 Series PLC. 2 Set the parameters as follows.[Dedicated Protocol] is selected for Protocol, [Sum Check] is checked, and [Form4] is selected for the Transmission Control Sequence.

    Aside from using [HC Parameter], the user can use the special data register D8120 in PLC to set the communication parameters for PLC.

    Special Data Registers Descriptions

    D8120

    D8121

    D8129

    Applicable to HCA8 and other HC Series PLCs using CH1

    Communication format

    Station No. setting

    Data network out-time counting

    * For example:If the PLC communication parameters are: 9600bps (Baud Rate), 7 (Data Bit), even (Parity Check), 2 (Stop Bit), 1(PLC Station No.), RS485 (Communication Method) and 1) (PLC Communication Time Out), then D8120=0xE08E, D8121=1, and D8129=1. Note: The settings will be valid when the PLC is restarted after the D8120 setting is modified.

    1-3-3 When Using HCFA HCA4 Communication Protocols

    HMI SettingsHMI default communication parameters: 19200bps (Baud Rate), 7(DataBit), even (Parity Check), 2 (Stop Bit) and 0 (PLC Station No.)

    Rs422 Communication

    PLC SettingsDouble click [Setting] in the [Working list] of LC-Develpoer.

    Click the built-in RS422C port

    Before After

  • When using DC+5V power supply voltage of 6-pin connector from serial port COM1, confirm the consumption current of connecting devices is below 250mA.The voltage output of the TP Unit for the TP Unit is +5V±5%. The maximum current is 150mA.

    Precaution for safe use

    Pins Singals

    Sending data

    Receiving data

    DC+5V output (Max. current: 250mA)

    Signal ground

    Functions

    1-4 Supported Registers

    Device Bit Address Word Address Format Notes

    Input Relay

    Output Relay

    Auxiliary Relay

    Timer Contact

    Counter Contact

    Data Contact

    State

    Timer Value

    Counter Value

    Data Register

    Special Data Register

    Counter Value(32-bit) bit device

    Device Bit Address Word Address Format Notes

    Input Relay

    Output Relay

    Auxiliary Relay

    Timer Contact

    Counter Contact

    Data Contact

    State

    Timer Value

    Counter Value

    Data Register

    Special Data Register

    Counter Value(32-bit) bit device

    Device Bit Address Word Address Format Notes

    Input Relay

    Output Relay

    Auxiliary Relay

    Working Area

    Holding Area

    Data Register

    Timer Value

    Timer Contact

    Counter

    Counter Contact

    Auxiliary Register

    E-type CPU unit

    N-type CPU unit

    Read only

    Read/ write

    Device Bit Address Word Address Format Notes

    Input Relay

    Output Relay

    Auxiliary Relay

    Timer Contact

    Counter Contact

    Data Contact

    State

    Timer Value

    Counter Value

    Data Register

    Special Data Register

    Counter Value(32-bit) bit device

    Device Bit Address Word Address Format Notes

    Input Relay

    Output Relay

    Timer Contact

    Counter Contact

    Data Contact

    State

    Internal Relay

    Special Internal Relay

    Timer

    Counter

    Data Register

    Extension Register

    Special Data Register

    Counter Value(32-bit) bit device

    1-5 Cable Fabrication

    1-5-1 RS232 Communication Cable for HC seriesCPU port RS232 communication cable

    Make sure to use serial communtication port cables of HC series.

    TX□□-232-BD Communication cableHMI (Male) port PLC RS232

    (Female) Port

    1-5-2 RS485/422 Communication cable for HC seriesCommunication cable

    HMI (Male) port PLC RS422 (Female)

    Port

    Communication cableHMI (Male) port

    Connetor

    BackV iew

    Ethernet

    Input terminalDC24V

    min USB Programingport

    RESET

    COM1(Female)-RS232

    COM2(Female)-RS422/RS485/RS232

    1-6 Installation onto the Operation PanelInstall the TP Unit by embedding it into the operation panel.

    Use the metal kit and tool (a crosshead screwdriver) supplied with the Unit for installation.

    Proceed the installation following the procedures below.

    1. Panel cutout with dimensions is shown below. Fit the TP Unit into the panel from the front side.

    Width

    HeightOpening dimensions

    2. Installation method of TP unit is shown below.

    Models Opening Dimension (W * H mm)

    Gaskets

    Ampinfied parts

    Gaskets

    Gaskets groove

    Sectional view

    Insert Mounting holes

    Installationaccessories

    Screws

    Amplified parts

    Precaution for safe use

    ■ When operating on the operation panel, make sure to keep metal particles from entering the Unit.■The mounting panel must be between 1.6 and 4.8 mm thick. The NB Unit must be installed in a control panel.■For the sake of waterproof and dustproof, all the fixators must be evenly tightened

    or the tightening is not even, deformation of the front panel may occur.■Make sure that the operation panel is clean, unbent, and strong enough for the installation process.

    to a torque of 0.5~0.6 N▪m. If the tightening torque exceeds the specified value,

    1-7 Part names

    TL1310-TFT

    Front view

    POWER LEDlit/Not lit when the powerNO/OFF

    Display7-inch WVGA wide TFT LCDInpout operation cn be carried out by the touch panel.

    Back wiew

    Ethernet

    min USB Programing portCOM2(Female)-RS422/RS485/RS232

    DC24VInput terminal

    RESET

    1-8 Part Specifications●Touch PanelInput operation can be carried out by means of the touch panel. By pressing the touch panel, the screens can be switched, and the contact information can be transmitted to the host.

    ■Press a touch switch with a 0.8~1.2N force.■Do not accidentally press the touch panel when the backlight is not lit or when the display does not appear. Make sure of the safety of the system before pressing the touch panel.■Confirm the safety of the system before pressing the touch panel.■Do not use hard or pointed objects to operate or scrub the screen, or the surface of the screen may be damaged.■Signals from the touch switches may not be input if the switches are pressed consecutively at high speed. Confirm each input before proceeding to the next one.■Deterioration over t ime can cause the touch points to move. I f deviation of the touch points stands out, calibrate the touch panel periodically.

    Precautions for Safe Use

    ●Serial Port COM1■TL1370-WTFT &TL1310-WTFTSerial port COM1 is a 9-pin D-type socket port. This port supports RS-232C communicat ion funct ion, making i t connectable to a control ler which features RS-232C funct ion, and i t can also be used for downloading programs or debugging for the product.The pins are defined as fol lows:

    Pins SingalsFunctions

    Terminal R1

    Terminal R1

    Sending data

    Receiving data

    Terminal resistor 1

    Terminal resistor 2

    Receiving data

    RS485B

    RS485A

    Sending data

    Receiving data

    Sending data

    Receiving data

    Precaution for safe use

    Confirm the safety of the system before turning ON or OFF the power supply, or pressing the reset button.

    ■TL1370-WTFT &TL1310-WTFT●Serial Port COM2

    Serial port COM2 is a 9-pin D-type socket port. This port supports RS-232C/RS-485/RS-422A communication function.The pins are defined as follows:

    COM1(Female)-RS232

    1-9 Part names