HECHUANFX2N-32MR
HECHUANFX2N-32MR
HCFA CORPORATION LIMITED
User's manual
Thanks for purchasing HCFA HMI products!
Our hard working, your better life!
series(HMI)
Port
Port
Port
Notes:For communication protocol, refer to section 1-1 for more details.For communication parameter, refer to section 1-3 for more details.
Make sure COM2 communication port and attached cable
TP13-PLC-R4-8P-3M are used in HCFA HC/LC series.
Communication type is set to RS422 in the software.
1-1 Serial communication port
Series UPU Link port Communication protocolParameter setting
Series
Refer to section 1-3-1
Refer to section 1-3-2
Refer to section 1-3-1
Refer to section 1-3-1
Refer to section 1-3-2
Refer to section 1-3-1
Refer to section 1-3-1
Refer to section 1-3-2
Refer to section 1-3-1
Refer to section 1-3-1
Refer to section 1-3-2
Refer to section 1-3-1
Refer to section 1-3-1
Refer to section 1-3-2
Refer to section 1-3-1
Refer to section 1-3-3
Dedicated Protocol(Mult i-Stat ion)
Dedicated Protocol(Mult i-Stat ion)
Dedicated Protocol(Mult i-Stat ion)
Dedicated Protocol(Mult i-Stat ion)
Dedicated Protocol(Mult i-Stat ion)
1-2 Serial port parameter and cable fabrication
Series
Series UPC Link port COOM Type Parameter Cable
Refer to section 1-5
Refer to section 1-5
Refer to section 1-5
Refer to section 1-5
Refer to section 1-5
Refer to section 1-5
Refer to section 1-5
Refer to section 1-5
Refer to section 1-5
Refer to section 1-5
Refer to section 1-5
Updated HCFA PLC Model name
1-3 Communication Setting
1-3-1 When Using HCFA HCA1, HCA2, HCA5, HCA6, HCA8 Communication Protocols
HMI SettingsHMI default communication parameters: 9600bps (Baud Rate), 7 (Data Bit), even (Parity Check), 1 (Stop Bit) and 0 (PLC Station No.)The PLC Communication Time Out, Max interval of word (bit) block pack, Max size of word(bit) block package on the right of the dialog box vary with PLC protocols. Generally the defaults are selected.
RS422 Communication
RS232 Communication
PLC SettingsThe PLC setting is as shown below when HCFA HCA1, HCA2, HCA5, HCA6, HCA8 communication protocols are used:1. Double-click the [PLC Parameter] under [Project Data List] in TP-Software
2. Open the [TX Parameter] dialog box.
3. Click the [Default] button to make settings without checking the [Communication Setting]:
Note: 1 The communication protocols such as HCFA HCA1, HCA2, HCA5, HCA6, and HCA8 etc. can be selected according to PLC model if the Station No. is not used when the communication is realized through the communication function expansion board.' 2 Make sure the value of communication format D8120 is 0 when the communication is realized through the communication function expansion board.
1-3-2 When Using 'Dedicated protocol (Multi-station)' Communication Protocols
HMI SettingsHMI default communication parameters: 19200bps (Baud Rate), 7(Data Bit), even (Parity Check), 2 (Stop Bit) and 0 (PLC Station No.)Note: The protocols are only applicable to PLCs communicating through communication function expansion board and support Multiple Station No. and Baud Rate settings
RS422 Communication
RS232 Communication
PLC SettingsThe PLC setting is as shown below when 'Dedicated protocol (Multi-station)' communication protocols are used.1. Double-click the [PLC Parameter] under [Project Data List] on the left of TP-Software.
2. Open the [TX Parameter] dialog box.
3. Parameters for HCA1, HCA2 and HCA5 are shown below.
Check the [Operate communication setting] optionNote :1 Set the parameters as follows.The [Dedicated Protocol] is selected for Protocol, the [Sum Check] is checked, and [Form4] is selected for the Transmission Control Sequence.
4. Parameters for HCA8 are shown below.
Check the [Operate communication setting] option.Note: 1 The [CH1] should be selected for HCA8 Series PLC. 2 Set the parameters as follows.[Dedicated Protocol] is selected for Protocol, [Sum Check] is checked, and [Form4] is selected for the Transmission Control Sequence.
Aside from using [HC Parameter], the user can use the special data register D8120 in PLC to set the communication parameters for PLC.
Special Data Registers Descriptions
D8120
D8121
D8129
Applicable to HCA8 and other HC Series PLCs using CH1
Communication format
Station No. setting
Data network out-time counting
* For example:If the PLC communication parameters are: 9600bps (Baud Rate), 7 (Data Bit), even (Parity Check), 2 (Stop Bit), 1(PLC Station No.), RS485 (Communication Method) and 1) (PLC Communication Time Out), then D8120=0xE08E, D8121=1, and D8129=1. Note: The settings will be valid when the PLC is restarted after the D8120 setting is modified.
1-3-3 When Using HCFA HCA4 Communication Protocols
HMI SettingsHMI default communication parameters: 19200bps (Baud Rate), 7(DataBit), even (Parity Check), 2 (Stop Bit) and 0 (PLC Station No.)
Rs422 Communication
PLC SettingsDouble click [Setting] in the [Working list] of LC-Develpoer.
Click the built-in RS422C port
Before After
When using DC+5V power supply voltage of 6-pin connector from serial port COM1, confirm the consumption current of connecting devices is below 250mA.The voltage output of the TP Unit for the TP Unit is +5V±5%. The maximum current is 150mA.
Precaution for safe use
Pins Singals
Sending data
Receiving data
DC+5V output (Max. current: 250mA)
Signal ground
Functions
1-4 Supported Registers
Device Bit Address Word Address Format Notes
Input Relay
Output Relay
Auxiliary Relay
Timer Contact
Counter Contact
Data Contact
State
Timer Value
Counter Value
Data Register
Special Data Register
Counter Value(32-bit) bit device
Device Bit Address Word Address Format Notes
Input Relay
Output Relay
Auxiliary Relay
Timer Contact
Counter Contact
Data Contact
State
Timer Value
Counter Value
Data Register
Special Data Register
Counter Value(32-bit) bit device
Device Bit Address Word Address Format Notes
Input Relay
Output Relay
Auxiliary Relay
Working Area
Holding Area
Data Register
Timer Value
Timer Contact
Counter
Counter Contact
Auxiliary Register
E-type CPU unit
N-type CPU unit
Read only
Read/ write
Device Bit Address Word Address Format Notes
Input Relay
Output Relay
Auxiliary Relay
Timer Contact
Counter Contact
Data Contact
State
Timer Value
Counter Value
Data Register
Special Data Register
Counter Value(32-bit) bit device
Device Bit Address Word Address Format Notes
Input Relay
Output Relay
Timer Contact
Counter Contact
Data Contact
State
Internal Relay
Special Internal Relay
Timer
Counter
Data Register
Extension Register
Special Data Register
Counter Value(32-bit) bit device
1-5 Cable Fabrication
1-5-1 RS232 Communication Cable for HC seriesCPU port RS232 communication cable
Make sure to use serial communtication port cables of HC series.
TX□□-232-BD Communication cableHMI (Male) port PLC RS232
(Female) Port
1-5-2 RS485/422 Communication cable for HC seriesCommunication cable
HMI (Male) port PLC RS422 (Female)
Port
Communication cableHMI (Male) port
Connetor
BackV iew
Ethernet
Input terminalDC24V
min USB Programingport
RESET
COM1(Female)-RS232
COM2(Female)-RS422/RS485/RS232
1-6 Installation onto the Operation PanelInstall the TP Unit by embedding it into the operation panel.
Use the metal kit and tool (a crosshead screwdriver) supplied with the Unit for installation.
Proceed the installation following the procedures below.
1. Panel cutout with dimensions is shown below. Fit the TP Unit into the panel from the front side.
Width
HeightOpening dimensions
2. Installation method of TP unit is shown below.
Models Opening Dimension (W * H mm)
Gaskets
Ampinfied parts
Gaskets
Gaskets groove
Sectional view
Insert Mounting holes
Installationaccessories
Screws
Amplified parts
Precaution for safe use
■ When operating on the operation panel, make sure to keep metal particles from entering the Unit.■The mounting panel must be between 1.6 and 4.8 mm thick. The NB Unit must be installed in a control panel.■For the sake of waterproof and dustproof, all the fixators must be evenly tightened
or the tightening is not even, deformation of the front panel may occur.■Make sure that the operation panel is clean, unbent, and strong enough for the installation process.
to a torque of 0.5~0.6 N▪m. If the tightening torque exceeds the specified value,
1-7 Part names
TL1310-TFT
Front view
POWER LEDlit/Not lit when the powerNO/OFF
Display7-inch WVGA wide TFT LCDInpout operation cn be carried out by the touch panel.
Back wiew
Ethernet
min USB Programing portCOM2(Female)-RS422/RS485/RS232
DC24VInput terminal
RESET
1-8 Part Specifications●Touch PanelInput operation can be carried out by means of the touch panel. By pressing the touch panel, the screens can be switched, and the contact information can be transmitted to the host.
■Press a touch switch with a 0.8~1.2N force.■Do not accidentally press the touch panel when the backlight is not lit or when the display does not appear. Make sure of the safety of the system before pressing the touch panel.■Confirm the safety of the system before pressing the touch panel.■Do not use hard or pointed objects to operate or scrub the screen, or the surface of the screen may be damaged.■Signals from the touch switches may not be input if the switches are pressed consecutively at high speed. Confirm each input before proceeding to the next one.■Deterioration over t ime can cause the touch points to move. I f deviation of the touch points stands out, calibrate the touch panel periodically.
Precautions for Safe Use
●Serial Port COM1■TL1370-WTFT &TL1310-WTFTSerial port COM1 is a 9-pin D-type socket port. This port supports RS-232C communicat ion funct ion, making i t connectable to a control ler which features RS-232C funct ion, and i t can also be used for downloading programs or debugging for the product.The pins are defined as fol lows:
Pins SingalsFunctions
Terminal R1
Terminal R1
Sending data
Receiving data
Terminal resistor 1
Terminal resistor 2
Receiving data
RS485B
RS485A
Sending data
Receiving data
Sending data
Receiving data
Precaution for safe use
Confirm the safety of the system before turning ON or OFF the power supply, or pressing the reset button.
■TL1370-WTFT &TL1310-WTFT●Serial Port COM2
Serial port COM2 is a 9-pin D-type socket port. This port supports RS-232C/RS-485/RS-422A communication function.The pins are defined as follows:
COM1(Female)-RS232
1-9 Part names