PEG-C Series  Cast Iron Gas-Fired Steam Boilers Quality Engineered for Efficiency and Dependability  
Transcript
Page 1: Utica PEG-C Gas Fired Steam Boilers Brochure

8/8/2019 Utica PEG-C Gas Fired Steam Boilers Brochure

http://slidepdf.com/reader/full/utica-peg-c-gas-fired-steam-boilers-brochure 1/4

PEG-C Series

Cast Iron Gas-Fired Steam BoilersQuality Engineered for Efficiency and Dependability

Page 2: Utica PEG-C Gas Fired Steam Boilers Brochure

8/8/2019 Utica PEG-C Gas Fired Steam Boilers Brochure

http://slidepdf.com/reader/full/utica-peg-c-gas-fired-steam-boilers-brochure 2/4

Page 3: Utica PEG-C Gas Fired Steam Boilers Brochure

8/8/2019 Utica PEG-C Gas Fired Steam Boilers Brochure

http://slidepdf.com/reader/full/utica-peg-c-gas-fired-steam-boilers-brochure 3/4

Fuel Saving Components Advanced engineering can be found in every part of aPEG-C boiler. An optional “on-demand” ignition controleliminates wasted fuel associated with a continuously burning pilot light.In addition, anintegrated automatic

 vent damper closes

 when the burnershuts off, preventingheat from leavingthrough the chimney saving fuel andheating costs. Factory Tested, Ready to Install

Following a series of rigorous tests, each PEG-C boilerleaves Utica Boilers as a completely packaged and cratedunit — ready to install and fire.

Manufacturer’s Warranty The Utica Boilers PEG-C is covered by a manufacturer’s10-year warranty for residential installations. In addition,

 your heating system is backed by an Americancommitment to quality that is synonymous with theUtica Boilers name. Should it be necessary, repair andservice parts are readily available through our nationwidedistribution network.

Key PEG-C Boiler Features

• Cast Iron Sections

• Corrosion Resistant Stainless Steel Burners

• Water-Tight Cast Iron Push Nipples

• Standard or Electronic Ignition

• 112,500-299,999 BTU/h input

• Integral Draft Hood, Natural DraftConventional Chimney Vented

• Natural Gas or Propane

The PEG-C is equipped with a number of safety devices that protect yourfamily. A low 

 water cut-off constantly monitors

 water levels,aiding in preventing a “dry-firing”and potential boiler failure. Inaddition, two thermally activated

safety sensors automatically shut off the gasburners should the chimney or heat exchanger

become blocked. Noguess work when yoursafety is concerned.

Built-In Safety Devices

Page 4: Utica PEG-C Gas Fired Steam Boilers Brochure

8/8/2019 Utica PEG-C Gas Fired Steam Boilers Brochure

http://slidepdf.com/reader/full/utica-peg-c-gas-fired-steam-boilers-brochure 4/4

PEG-C Series  Natural Gas Steam Boilers 

SERIES PEG-C NATURAL GAS STEAM BOILERS

 Your Assurance of Quality Utica Boilers products are designed,tested, and assembled to ensure that youget the very best in home heating andcooling comfort, and value. Each onemeets or exceeds all recognized safety,performance, and efficiency standards.

MEA# 17-79

*NOTE: For altitudes above 2,000 ft., ratings should be reduced at the rate of 4% for each 1,000 ft. above sea level.

STANDARD EQUIPMENT: Crated Cast Iron Boiler, Drafthood, Low Water Cut-off (Probe Type), Deluxe Jacket, Wiring, Automatic Vent Damper, Stainless Steel Burners, Blocked Vent and Roll-out Safety Switches, Gas Valve, Pilot, Pressure High LimitControl, Pressure Gauge, Gauge Glass, 2-2" Supply Tappings, 2-2" Return Tappings - L.H. Plugged. Packed in a separate carton:Pop Safety Valve and Boiler Drain. Stack Damper shipped in separate cartons within the crate on all models except PEG300C.

L E F T S I D E V I E W F R O N T V I E W R I G H T S I D E V I E W

The Ratings marked “Net I=B=R Ratings”indicate the amount of equivalent directcast iron radiation each boiler will take careof under normal conditions and thermostaticcontrol. The Net I=B=R Steam Ratingsshown are based on a piping and pickupallowance of 1.333. Proper allowance hasbeen made for piping and pickup inaccordance with the factors shown in theI=B=R Standard as published by The

Hydronics Institute.

Selection of boiler size should be basedon the net BTU per hour output of theconnected radiation and system piping.

The manufacturer should be consultedbefore selecting a boiler for installationshaving unusual piping and pickuprequirements, such as intermittent systemoperation, extensive piping systems, etc.

Specifications and dimensions are subjectto change without notice.

ANNUAL FUELNET I=B=R UTILIZATION EFFICIENCY

BOILER *A G A HEATING STEAM GASDIMENSIONS

(AFUE)

NUMBER INPUT CAPACITY RATING INLET ELECT. STD.BTU/HR. BTU/HR. BTU/HR SQ. FT. SIZE A B C D E F G IGN. & PILOT &

DAMPER DAMPER

PEG112C 112,500 90,000 67,500 281 1/2 141  ⁄  4 27 5  ⁄  8 241  ⁄  8 5 31  ⁄  2 6 443  ⁄  4 82.0 78

PEG150C 150,000 120,000 90,000 375 1/2 171  ⁄  8 285  ⁄  8 245  ⁄  8 6 4 61  ⁄  2 451  ⁄  4 82.0 78

PEG187C 187,500 151,000 113,300 472 1/2 20 295  ⁄  8 251  ⁄  8 7 41  ⁄  2 7 453  ⁄  4 82.0 78PEG225C 225,000 181,000 135,800 556 3/4 2213  ⁄  16 305  ⁄  8 255  ⁄  8 8 5 8 463  ⁄  4 82.0 78

PEG262C 262,500 212,000 159,000 663 3/4 255  ⁄  8 305  ⁄  8 255  ⁄  8 8 5 8 463  ⁄  4 82.0 78

PEG300C 299,999 243,000 182,300 760 3/4 281  ⁄  8 315  ⁄  8 261  ⁄  8 9 51  ⁄  2 10 483  ⁄  4 81.0 78

Explanation Notes

Tested for15 lbs. ASME

Working Pressure

Part # 240005085 Rev. 10/08

Dimensions

An ISO 9001-2000Certified Company

P.O. Box 4729Utica, New York 13504Tel. 315-797-1310Fax 866-432-7329E-mail: [email protected]

 Web Site: www.uticaboilers.com

USA Contractor Assistance:

800-325-5479


Recommended