Claire Fritz Market Manager, VHP Utilizing Integrated Vapor Phase Hydrogen Peroxide (VPHP) for Decontamination of Cleanrooms and other Critical Environments
Transcript
Page 1: Utilizing Integrated Vapor Phase Hydrogen Peroxide …. Reactivation Air Inlet. Warm Wet Air Exhaust. Process Air Inlet. Dry Air Outlet. Air Inlet. ... Room 1. Room 2.

Claire FritzMarket Manager, VHP

Utilizing Integrated Vapor Phase Hydrogen Peroxide (VPHP) for

Decontamination of Cleanrooms and other Critical Environments

Page 2: Utilizing Integrated Vapor Phase Hydrogen Peroxide …. Reactivation Air Inlet. Warm Wet Air Exhaust. Process Air Inlet. Dry Air Outlet. Air Inlet. ... Room 1. Room 2.

Agenda

• WHY??• History• Introduction to Vapor Phase Hydrogen

Peroxide• Variables Affecting Efficacy• Integrated Systems & Design Considerations• Validation

Page 3: Utilizing Integrated Vapor Phase Hydrogen Peroxide …. Reactivation Air Inlet. Warm Wet Air Exhaust. Process Air Inlet. Dry Air Outlet. Air Inlet. ... Room 1. Room 2.

WHY??- When manual disinfection is not enough…

• Large scale contamination • Flood, earthquake, hurricane, power failure• Renovation, new construction, shutdowns

Page 4: Utilizing Integrated Vapor Phase Hydrogen Peroxide …. Reactivation Air Inlet. Warm Wet Air Exhaust. Process Air Inlet. Dry Air Outlet. Air Inlet. ... Room 1. Room 2.

History• For over 100 yrs.: liquid hydrogen

peroxide is used as a germicide.• In the late 1980s, American Sterilizer

Company (now STERIS) discovered that hydrogen peroxide in vapor phase kills spores at low concentrations and short contact times.

• The first commercial portable VHP®

generator was available in 1991 and used primarily for isolator applications.

Page 5: Utilizing Integrated Vapor Phase Hydrogen Peroxide …. Reactivation Air Inlet. Warm Wet Air Exhaust. Process Air Inlet. Dry Air Outlet. Air Inlet. ... Room 1. Room 2.

History

• Integrated systems for isolators became available in the late 90s.

• Anthrax attacks in 2001 resulted in a huge increase for decontamination of laboratories.

• Now large capacity integrated units are being installed for large volume critical environments as a built-in utility.

Page 6: Utilizing Integrated Vapor Phase Hydrogen Peroxide …. Reactivation Air Inlet. Warm Wet Air Exhaust. Process Air Inlet. Dry Air Outlet. Air Inlet. ... Room 1. Room 2.

Vapor Phase Hydrogen Peroxide Process

2H2 O2

2H2 O

O2

+Sporicidal at LowConcentrations

(Typically 0.2-2 mg/L at 25oC)

Ambient Temperature

Process

Vaporization35%

HydrogenPeroxide

Non-Toxic Residues

‘Vapor’ is defined as a substance that has an ambient state in the liquid phase; it does not mean that it cannot exist in a dry, gaseous phase.

Page 7: Utilizing Integrated Vapor Phase Hydrogen Peroxide …. Reactivation Air Inlet. Warm Wet Air Exhaust. Process Air Inlet. Dry Air Outlet. Air Inlet. ... Room 1. Room 2.

Limitations

• Does not work well on highly absorptive materials • Penetration can be limited due to instability • Surfaces must be reasonably clean• Surfaces must be dry

Page 8: Utilizing Integrated Vapor Phase Hydrogen Peroxide …. Reactivation Air Inlet. Warm Wet Air Exhaust. Process Air Inlet. Dry Air Outlet. Air Inlet. ... Room 1. Room 2.

Advantages

• DRY; Penetrates HEPA filters• Great Alternative to other toxic chemicals• Ambient Temperature• No Lengthy Aeration compared to other chemicals• Non-Toxic By-Products (water vapor and oxygen)• Residue Free• Excellent Material Compatibility• Repeatable

Page 9: Utilizing Integrated Vapor Phase Hydrogen Peroxide …. Reactivation Air Inlet. Warm Wet Air Exhaust. Process Air Inlet. Dry Air Outlet. Air Inlet. ... Room 1. Room 2.

Effective

• Highly sporicidal even as low as 0.2 mg/L• Able to achieve sterility in minutes• Destroys a wide range of microorganisms

Page 10: Utilizing Integrated Vapor Phase Hydrogen Peroxide …. Reactivation Air Inlet. Warm Wet Air Exhaust. Process Air Inlet. Dry Air Outlet. Air Inlet. ... Room 1. Room 2.

Variables Affecting Efficacy

Temperature and humidity affect how much can be generated in the gas stateConcentrationSaturation

Inject as much as possible but below dewpointHumidity is good for microbial kill

Page 11: Utilizing Integrated Vapor Phase Hydrogen Peroxide …. Reactivation Air Inlet. Warm Wet Air Exhaust. Process Air Inlet. Dry Air Outlet. Air Inlet. ... Room 1. Room 2.

How Is it Dry?

Low humidity air thru vaporizer for max. gaseous generationBegin enclosure at known humidity Constantly remove humidity

35% Hydrogen peroxide/ 65% water

Page 12: Utilizing Integrated Vapor Phase Hydrogen Peroxide …. Reactivation Air Inlet. Warm Wet Air Exhaust. Process Air Inlet. Dry Air Outlet. Air Inlet. ... Room 1. Room 2.

0.1

1

10

100

0 0.5 1 1.5 2 2.5 3 3.5

Vapor Conc. (mg/L)

Avg

. D-V

alue

(min

) Geobacillus stearothermophilusGeobacillus stearothermophilus spores inoculated spores inoculated on Stainless Steel Coupons at 30on Stainless Steel Coupons at 3000CC

Vapor Phase Hydrogen Peroxide

Microbial Kill Matrix

Page 13: Utilizing Integrated Vapor Phase Hydrogen Peroxide …. Reactivation Air Inlet. Warm Wet Air Exhaust. Process Air Inlet. Dry Air Outlet. Air Inlet. ... Room 1. Room 2.

00.5

11.5

22.5

33.5

4

0.4 0.6 0.8

Saturation (Act./Max.)

D-V

alue

(min

)D-value for 1.6 mg/L Versus

Percent Saturation

Page 14: Utilizing Integrated Vapor Phase Hydrogen Peroxide …. Reactivation Air Inlet. Warm Wet Air Exhaust. Process Air Inlet. Dry Air Outlet. Air Inlet. ... Room 1. Room 2.

Four Phase Vapor Phase Hydrogen Peroxide Cycle

1. Dehumidify

2. Condition

3. Decontaminate

4. Aerate

Page 15: Utilizing Integrated Vapor Phase Hydrogen Peroxide …. Reactivation Air Inlet. Warm Wet Air Exhaust. Process Air Inlet. Dry Air Outlet. Air Inlet. ... Room 1. Room 2.

Vapor Phase Hydrogen Peroxide Decontamination Cycle

If the humidity is controlled throughout the cycle, the hydrogen peroxide will remain in the dry, gaseous phase.

Page 16: Utilizing Integrated Vapor Phase Hydrogen Peroxide …. Reactivation Air Inlet. Warm Wet Air Exhaust. Process Air Inlet. Dry Air Outlet. Air Inlet. ... Room 1. Room 2.

Closed Loop Configuration

Sealed Enclosure

H2 O2Reservoir

Vaporizer

HEPAFilter

DesiccantChamber

Pre-Heater

CatalyticConverter

HEPAFilter

H2 O2Cartridge

Page 17: Utilizing Integrated Vapor Phase Hydrogen Peroxide …. Reactivation Air Inlet. Warm Wet Air Exhaust. Process Air Inlet. Dry Air Outlet. Air Inlet. ... Room 1. Room 2.

Single Pass & Integrated Configuration

Vaporizer

Controls

Blower

Enclosure Valve

Dry Air In

Air Out

H2 O2

Page 18: Utilizing Integrated Vapor Phase Hydrogen Peroxide …. Reactivation Air Inlet. Warm Wet Air Exhaust. Process Air Inlet. Dry Air Outlet. Air Inlet. ... Room 1. Room 2.

Dryer Generator

Reactivation Air Inlet

Warm Wet Air Exhaust

Process Air Inlet

Dry Air Outlet

Air Inlet

Sterilant Outlet

Principle Diagram for Integrated System

Room 1

Room 2

Etc … Etc …Room

1Room

2Etc … Etc …

OptionalCatalytic Converter

ExtractionFan

Page 19: Utilizing Integrated Vapor Phase Hydrogen Peroxide …. Reactivation Air Inlet. Warm Wet Air Exhaust. Process Air Inlet. Dry Air Outlet. Air Inlet. ... Room 1. Room 2.

1.Pipework separate from the HVAC2.Using HVAC system

Integration

Page 20: Utilizing Integrated Vapor Phase Hydrogen Peroxide …. Reactivation Air Inlet. Warm Wet Air Exhaust. Process Air Inlet. Dry Air Outlet. Air Inlet. ... Room 1. Room 2.

Integration1. Pipework separate from the HVAC

ApplicationExample

Page 21: Utilizing Integrated Vapor Phase Hydrogen Peroxide …. Reactivation Air Inlet. Warm Wet Air Exhaust. Process Air Inlet. Dry Air Outlet. Air Inlet. ... Room 1. Room 2.

Integration1. Pipework separate from the HVAC

Pipework is CPVC/PP.Inlet pipes are insulated (not heat traced). HVAC is stopped and the airtight dampers are closed during

Dehumidification and Injection Phases. HVAC system is restartedfor Aeration.

Flow between rooms will have to be adjusted during commissioning and simple adjustable butterfly dampers will be needed per room.

Butterfly valves will be installed at each room or the pipe will be installed at the back of the room’s HEPA filter entry.

Pressure (Positive or Negative) control during Decontamination can be achieved on small and/or leaktight rooms by the exhaust fan.

Page 22: Utilizing Integrated Vapor Phase Hydrogen Peroxide …. Reactivation Air Inlet. Warm Wet Air Exhaust. Process Air Inlet. Dry Air Outlet. Air Inlet. ... Room 1. Room 2.

Integration2. Using HVAC system

ApplicationExample

Page 23: Utilizing Integrated Vapor Phase Hydrogen Peroxide …. Reactivation Air Inlet. Warm Wet Air Exhaust. Process Air Inlet. Dry Air Outlet. Air Inlet. ... Room 1. Room 2.

Integration

Pipework to HVAC is made of CPVC/PP.Inlet pipes are insulated (not heat traced). HVAC is running in a closed loop only, no fresh air is admitted

during Dehumidification and Injection Phases. Then maximum freshair for Aeration.

Recirculation with the HVAC will allow an equal distribution of the gas.

The cooling and heating of the HVAC will be stopped (Aluminum , Stainless Steel or Epoxy coated; no copper).

2. Using HVAC system

Page 24: Utilizing Integrated Vapor Phase Hydrogen Peroxide …. Reactivation Air Inlet. Warm Wet Air Exhaust. Process Air Inlet. Dry Air Outlet. Air Inlet. ... Room 1. Room 2.

Large Room Capacity

>32,000 ft3 (900m3) volume and 28 ft. (8.5 m) ceiling height

Page 25: Utilizing Integrated Vapor Phase Hydrogen Peroxide …. Reactivation Air Inlet. Warm Wet Air Exhaust. Process Air Inlet. Dry Air Outlet. Air Inlet. ... Room 1. Room 2.

Pass-through ChamberIntegrated VPHP can be used for:

Equipment/Packaging/Other Cleanroom /Heat sensitive items

Achieving shortest cycle times

To achieve 6 log kill: 15 minutes – 1 hr.

Page 26: Utilizing Integrated Vapor Phase Hydrogen Peroxide …. Reactivation Air Inlet. Warm Wet Air Exhaust. Process Air Inlet. Dry Air Outlet. Air Inlet. ... Room 1. Room 2.

Validation: Efficacy• Methods:

– Geobacillus stearothermophilus Biological Indicators (BI)• Packaged in Tyvek® or ‘naked’• Inoculated side face up• Hang with paper clips/tape

– User Made Inoculated Coupons• Can be inconsistent• Issues with reusing stainless steel • Material properties affect resistance

*Photos are Courtesy of Advanced Barrier Concepts

Page 27: Utilizing Integrated Vapor Phase Hydrogen Peroxide …. Reactivation Air Inlet. Warm Wet Air Exhaust. Process Air Inlet. Dry Air Outlet. Air Inlet. ... Room 1. Room 2.

Validation: Efficacy

• Population– 106 is most common– Lower population can be justified for low

bioburden isolators– Population verification

• Locations– Worst case– Critical areas– Indicator cannot be blocked

• Multiple indicators per location– Potential outliers

• D-value testing– Actual vs. Vendor’s

Page 28: Utilizing Integrated Vapor Phase Hydrogen Peroxide …. Reactivation Air Inlet. Warm Wet Air Exhaust. Process Air Inlet. Dry Air Outlet. Air Inlet. ... Room 1. Room 2.

Concentration Monitoring• Room monitors for outside of space

• Low end sensor to detect levels inside space before entry

• High end sensor to measure decontamination levelsHUMIDITY STUDY USING 31% H2O2

UOP H2O2 Monitor S/N 1011 20 SCFM at 2.2 g/m

-0.2

0.0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

0 50 100 150 200 250 300 350Time (min)

VHP

Conc

entr

atio

n (m

g/L)

-2.0

0.0

2.0

4.0

6.0

8.0

10.0

12.0

14.0

16.0

18.0

20.0

22.0

24.0

26.0

Water C

oncentration (mg/L)

VHP

WATER

VHP Exposure Average = 1.05 +/- 0.02

Water Vapor Exposure Average = 3.51 +/- 0.05

Page 29: Utilizing Integrated Vapor Phase Hydrogen Peroxide …. Reactivation Air Inlet. Warm Wet Air Exhaust. Process Air Inlet. Dry Air Outlet. Air Inlet. ... Room 1. Room 2.

Concentration Monitoring

Hand heldSensor

Low end Sensor

High end sensor

Page 30: Utilizing Integrated Vapor Phase Hydrogen Peroxide …. Reactivation Air Inlet. Warm Wet Air Exhaust. Process Air Inlet. Dry Air Outlet. Air Inlet. ... Room 1. Room 2.

QUESTIONS???