+ All Categories
Home > Documents > V ! Advantages of Application of LEDs LIGHTING.pdf · 2009-02-26 · Specification V !30W 60W 100W...

V ! Advantages of Application of LEDs LIGHTING.pdf · 2009-02-26 · Specification V !30W 60W 100W...

Date post: 06-Jul-2020
Category:
Upload: others
View: 0 times
Download: 0 times
Share this document with a friend
24
Advantages of Application of LEDs 1 Energy Saving Long Life Environmental Protectiong Various Option Solid State Semiconductor Lighting
Transcript
Page 1: V ! Advantages of Application of LEDs LIGHTING.pdf · 2009-02-26 · Specification V !30W 60W 100W Flood light. Input Voltage Correlated Color Temp. Operating Temp. Power Factor Beam

Advantages of Application of LEDs

1

Energy Saving

Long Life

Environmental Protectiong

Various Option

Solid State Semiconductor Lighting

Page 2: V ! Advantages of Application of LEDs LIGHTING.pdf · 2009-02-26 · Specification V !30W 60W 100W Flood light. Input Voltage Correlated Color Temp. Operating Temp. Power Factor Beam

BF Type Street Lamps P3~6 Solar Street Lamps P7~8

Projecting Light P9~12 Flood Light P13~14

Tunnel Lights P15~18 Indoor Lighting Products P19~24

2

Led Outdoor Lighting Series

Page 3: V ! Advantages of Application of LEDs LIGHTING.pdf · 2009-02-26 · Specification V !30W 60W 100W Flood light. Input Voltage Correlated Color Temp. Operating Temp. Power Factor Beam

3

Features

Polar Candela Distribution

Page 4: V ! Advantages of Application of LEDs LIGHTING.pdf · 2009-02-26 · Specification V !30W 60W 100W Flood light. Input Voltage Correlated Color Temp. Operating Temp. Power Factor Beam

90~264 VAC

4745~5310 K

-30~+40°C

>0.9

±55°

20°

IP66

>25,000 hrs

475×318×155mm

7 kg

Input Voltage

Correlated Color Temp.

Operating Temp.

Power Factor

Max Candela Angle

Eccentric Angel

Ingress Protection

Life Time

Dimension

Weight

Beam Angel

Parameters Ratings

Input Power 30W 60W 100W

Lamp Total Flux

Lamp Height

Arm Angle

Arm Length

Road Width

Distance of Poles

1980 lm

5m

15°

1m

7m

15m

2960 lm

6m

15°

1m

12m

18m

5600 lm

8m

15°

1m

16m

24m

Install single

side of a road

Street lights are directlyopposite to each otheron the road

Installing Methods

Simulating Result

Input power

Min. illuminance ( Iux)

Avg. illuminance ( Iux)

Uniformity=Min. illuminance

/ Avg. illuminance

30W (OH)

5.7

12

0.47

60W (BF)

15

25

0.58

100W (BF)

13

23

0.56

4

Applications & Constructions Installing Conditions

Street lights with wide beam angle.Bended-arm and installed with a pole of 60mm in diameter.

Page 5: V ! Advantages of Application of LEDs LIGHTING.pdf · 2009-02-26 · Specification V !30W 60W 100W Flood light. Input Voltage Correlated Color Temp. Operating Temp. Power Factor Beam

5

Features

Polar Candela Distribution

150W 200W 100W Wide Optical Pattern Street Light.

Page 6: V ! Advantages of Application of LEDs LIGHTING.pdf · 2009-02-26 · Specification V !30W 60W 100W Flood light. Input Voltage Correlated Color Temp. Operating Temp. Power Factor Beam

6

90~264 VAC

4745~5310 K

-30~+40°C

>0.9

±55°

20°

IP66

>25,000 hrs

839×450×155mm

18 kg

Input Voltage

Correlated Color Temp.

Operating Temp.

Power Factor

Max Candela Angle

Eccentric Angel

Ingress Protection

Life Time

Dimension

Weight

Beam Angel

Parameters Ratings

Input Power 150W 200W

Lamp Total Flux

Lamp Height

Arm Angle

Arm Length

Road Width

Distance of Poles

Installing Methods

9900 lm

10m

15°

1m

20m

30m

12000 lm

12m

15°

1m

24m

36m

Street lights are directly oppositeto each other on the road.

Min. illuminance ( Iux)

Avg. illuminance ( Iux)

Uniformity=Min. illuminance/ Avg. illuminance

150W

11

19

0.57

200W

12

18

0.7

Input power

Applications & Constructions Installing Conditions

Simulating Result

Street lights with wide beam angle.Bended-arm and installed with a pole of 60mm in diameter.

Page 7: V ! Advantages of Application of LEDs LIGHTING.pdf · 2009-02-26 · Specification V !30W 60W 100W Flood light. Input Voltage Correlated Color Temp. Operating Temp. Power Factor Beam

7

Features Polar Candela Distribution

30W 40W 60W Solar Street Light.

Applications & Constructions

Specifications

Input voltage

Correlated color Temp.

Operating Temp.

Power Factor

Max Candela Angle

Eccentric Angel

Ingress Protection

Life time

Dimension

Weight

90~264 VAC

4500~6000 K

-30~+40°C

>0.9

±55°

20°

IP66

>20,000 hrs

475×318×155mm

7 kg

30W

1,650 lm

40W

2,640 lm

60W

3,300 lm

Beam Angel

Total Flux фv ( typ.)

Parameters Ratings

Page 8: V ! Advantages of Application of LEDs LIGHTING.pdf · 2009-02-26 · Specification V !30W 60W 100W Flood light. Input Voltage Correlated Color Temp. Operating Temp. Power Factor Beam

Output Power

Max. Output Voltage and current

Solar Panel Type

Dimension

Weight

Output and input Voltage

Max. output and input Voltage & Current

Dimension

Weight

Output and input Voltage & Current

Dimension

Weight

Solar Panel

Controller

Battery

180 Watt* 1pcs

36V, 5.01A

Single crystalline 125*125mm*72 pcs

1580mm*806mm*35mm

15 kg/pcs

12V or 24V could be recognized automatically

8A

100mm*80mm*32mm

0.18 kg

12V, 100Ah*2pcs

407mm*173mm*240mm

31kg/pcs

When Batteries full charged, a 30W LED streets light is able to be applied for 6 cloudy or raining days.( 40W and 60W for 3days )

FunctionsItems Quantities and spec.

Lamp Total Flux

Lamp Height

Arm Angle

Arm Length

Road Width

Distance of Poles

Installing Methods

1650 lm

5m

15°

1m

7m

15mInstall single

side of a road

Street lights are directlyopposite to each other on the road

Street lights are directlyopposite to each other on the road

Input Power

2640 lm

5m

15°

1m

7m

15m

3300 lm

6m

15°

1m

12m

18m

30W 40W 60W

8

Specifications of Solar Components

Installing Conditions

Page 9: V ! Advantages of Application of LEDs LIGHTING.pdf · 2009-02-26 · Specification V !30W 60W 100W Flood light. Input Voltage Correlated Color Temp. Operating Temp. Power Factor Beam

30W 60W 100W Projecting Light

9

Features

Applications & Constructions

Polar Candela Distribution

Input Wattage

30W

60W

100W

Total Fluxфv ( typ. )

1980 lm

3960 lm

6600 lm

Page 10: V ! Advantages of Application of LEDs LIGHTING.pdf · 2009-02-26 · Specification V !30W 60W 100W Flood light. Input Voltage Correlated Color Temp. Operating Temp. Power Factor Beam

Input voltage

Correlated color Temp.

Operating Temp.

Power Factor

View Angle

Ingress Protection

Life time

Dimension

Weight

90~264 VAC

4745~5310 K

-30~+40°C

>0.9

X-X: ±40° , Y-Y: ±30°

IP66

>25,000 hrs

475×318×155

7 kg

Parameters Ratings Wattage

30W

60W

100W

Pole height Illumination Diameter of coverage

4

5

6

7

5

6

7

8

6

7

8

9

53

33

23

17

106

73

54

41

78

58

44

35

12

15

18

21

15

18

21

24

18

21

24

27

10

Specifications Simulating Result

Page 11: V ! Advantages of Application of LEDs LIGHTING.pdf · 2009-02-26 · Specification V !30W 60W 100W Flood light. Input Voltage Correlated Color Temp. Operating Temp. Power Factor Beam

11

Features

Applications & Constructions

Polar Candela Distribution

150W 200W Projecting Light.

Input Wattage

150W

200W

Total Fluxфv ( typ. )

9900 lm

12000 lm

Page 12: V ! Advantages of Application of LEDs LIGHTING.pdf · 2009-02-26 · Specification V !30W 60W 100W Flood light. Input Voltage Correlated Color Temp. Operating Temp. Power Factor Beam

12

Specifications Simulating Result

Input voltage

Correlated color Temp.

Operating Temp.

Power Factor

Max Candela Angle

Max Candela Angle

Ingress Protection

Life time

Dimension

Weight

90~264 VAC

4745~5310 K

-30~+40°C

>0.9

20°

IP66

>25,000 hrs

839×450×155

18kg

Beam Angel

Parameters Ratings

8

9

10

11

9

10

11

12

65

51

41

34

64

52

43

36

24

27

30

33

27

30

33

36

Note : The illumination is the value at the position under

the luminaries

Wattage

150W

200W

Pole height

(m)

Illumination

(Lux)

Diameter of coverage

(m)

X-X: ±40°

Y-Y: ±30°

Page 13: V ! Advantages of Application of LEDs LIGHTING.pdf · 2009-02-26 · Specification V !30W 60W 100W Flood light. Input Voltage Correlated Color Temp. Operating Temp. Power Factor Beam

13

Features

Applications & Constructions

Specification

30W 60W 100W Flood light.

Input Voltage

Correlated Color Temp.

Operating Temp.

Power Factor

Beam Angel

Ingress Protection

Life Time

Dimension

Weight

Parameters Ratings

90~264VAC

4745-5310K

-30~+40°C

>0.9

IP66

>20,000hrs

467×265×195 mm

6kg

X-X=±40°Y-Y=±30°

Input Wattage

30W

60W

100W

Total Fluxфv ( typ. )

1650 lm

3300 lm

5500 lm

Page 14: V ! Advantages of Application of LEDs LIGHTING.pdf · 2009-02-26 · Specification V !30W 60W 100W Flood light. Input Voltage Correlated Color Temp. Operating Temp. Power Factor Beam

14

Polar Candela Distribution Simulating Result

Wattage

30W

60W

100W

Projecting height

4

5

6

7

5

6

7

8

6

7

8

9

Illumination

53

33

23

17

106

73

54

41

78

58

44

35

Note: The illumination is the value at the position upon the luminaries.

Page 15: V ! Advantages of Application of LEDs LIGHTING.pdf · 2009-02-26 · Specification V !30W 60W 100W Flood light. Input Voltage Correlated Color Temp. Operating Temp. Power Factor Beam

Part No.

VWLR-EB30A03-220V

VWLR-EF30A03-220V

VWLR-EB60A03-220V

VWLR-EF60A03-220V

VWLR-EB100A03-220V

VWLR-EF100A03-220V

Item

30W Tunnel Light

60W Tunnel Light

100W Tunnel Light

Ratings

90~264VAC

4500-6000 K

-30~+40°C

>0.9

IP66

>20,000hrs

467×265×199mm

6kg

Input Voltage

Correlated Color Temp

Operating Temp

Power Factor

Ingress Protection

Life Time

Dimension

Weight

Parameters

15

Features

Specifications

30W 60W 100W Tunnel light.

Polar Candela Distribution

Page 16: V ! Advantages of Application of LEDs LIGHTING.pdf · 2009-02-26 · Specification V !30W 60W 100W Flood light. Input Voltage Correlated Color Temp. Operating Temp. Power Factor Beam

Beam Angle

Max Candela Angle(θ peak)

View Angle (2θ ½)

Direction

X-X

X-X

X-Y

Wide Angle Type

±55°

140°

±45°

Projecting Type

±30°

<100°

±30°

Input Wattage

30W

60W

100W

Total FluxψV (typ.)

1980 lm

3960 lm

6600 lm

Parameters

Lamp Height

Arm Angle

Arm Length

Road Width

Installing Methods

Ratings

5.5m

25°

1m

10m

The tunnel lights are located symmetrically opposite to one and another.

Wattage Speed (km/hr)

40

60

80

40

60

80

40

60

80

Lamp Distance (m) Ave. luminous (cd / )

1.50 ( 1.5)

2.30 ( 2.3)

4.50 ( 4.5)

1.51 ( 1.5)

2.36 ( 2.3)

4.53 ( 4.5)

1.51 ( 1.5)

2.30 ( 2.3)

4.53 ( 4.5)

Ave. lluminance (Lux)

26 ( 19.5)

39 ( 29.9)

77 ( 58.5)

26 ( 19.5)

40 ( 29.9)

77 ( 58.5)

26 ( 19.5)

39 ( 29.9)

77 ( 58.5)

9m

6m

3m

18m

11.5m

6m

36m

23.6m

12m

30W

60W

100W

16

Installing Conditions

Simulating result

Page 17: V ! Advantages of Application of LEDs LIGHTING.pdf · 2009-02-26 · Specification V !30W 60W 100W Flood light. Input Voltage Correlated Color Temp. Operating Temp. Power Factor Beam

Part No.

VWLR-EB200A03-220V

VWLR-EF200A03-220V

VWLR-EB150A03-220V

VWLR-EF150A03-220V

200W Tunnel Light

150W Tunnel Light

Item

Beam Angle

Max Candela Angle

(θ peak)

View Angle (2θ 1/2)

Direction

X-X

X-X

X-Y

Wide Angle Type

±55°

140°

±45°

Projecting Type

±30°

<100°

±30°

17

Features

150W 200W Tunnel light.

Polar Candela Distribution

Page 18: V ! Advantages of Application of LEDs LIGHTING.pdf · 2009-02-26 · Specification V !30W 60W 100W Flood light. Input Voltage Correlated Color Temp. Operating Temp. Power Factor Beam

Wattage

200W

Speed (km/hr)

40

60

80

Lamp Distance (m)

50m

35m

18m

Ave. luminous (cd / )

1.6

( 1.5)

2.3

( 2.3)

4.5

( 4.5)

Ave. lluminance (Lux)

28

( 19.5)

40

( 29.9)

77

( 58.5)

Parameters Ratings

Input Voltage

Power Dissipation

Total Flux v (typ.)

Correlated Color Temp.

Operating Temp.

Power Factor

Ingress Protection

Life Time

Dimension

Weight

90~264VAC

150W 200W

99,000 lm 12,000 lm

4500-6000 K

-30~+40°C

>0.9

IP66

>20,000hrs

852×355×195mm

11kg

Parameters

Lamp Height

Arm Angle

Arm Length

Road Width

Installing Methods

Ratings

5.5m

25°

1m

10m

The tunnel lights are located symmetrically opposite to one and another.

18

Specification

Simulating result

Installing Conditions

Page 19: V ! Advantages of Application of LEDs LIGHTING.pdf · 2009-02-26 · Specification V !30W 60W 100W Flood light. Input Voltage Correlated Color Temp. Operating Temp. Power Factor Beam

Part No.

VAGS-GA02-30W57K-100-240V

VAGS-GA01-45W57K-100-240V

VAGS-GA02-60W57K-100-240V

VAGS-GA01-90W57K-100-240V

Size

600×600×80mm

600×600×80mm

600×1200×80mm

600×1200×80mm

Size

Input Voltage

LED Power Dissipation

Total Power Dissipation

Total Flux ( v)

CRI

Operating Temp.

Power Factor

Peak Angle (2 1/2)

Life Time

Weight

600×600×80mm

90~264VAC

30W 45W

40W±10% 60W±10%

2,500lm(typ.) 2,700lm(typ.)

Typ.:5700k

Range:5311~6020

65

-30~+40°C

>0.9

108°

>25,000 hrs

5 kg

600×1200×80mm

90~264VAC

60W 90W

70W±10% 100W±10%

5,250lm(typ.) 5,400lm(typ.)

Typ.:5700k

Range:5311~6020

65

-30~+40°C

>0.9

108°

>25,000 hrs

7 kg

CCT

Parameters Ratings

Part No.

Polar Candela Distribution

Specification

19

Features

Indoor Lighting Products.

Page 20: V ! Advantages of Application of LEDs LIGHTING.pdf · 2009-02-26 · Specification V !30W 60W 100W Flood light. Input Voltage Correlated Color Temp. Operating Temp. Power Factor Beam

Luminaire

LED(VAGS-

GA01-45W57K-

100-240V

T5(Electronic

Ballast)

T8(Electronic

Ballast)

T8(Magnetic

Ballast) Note

Power consumption 58W 66W 81W 112W

Annual energy

consumption(KWH/year) 245 289 354.5 490.5

Lighting 12hours/day

Annual electricity

cost (RMB$/year) 171.5 202.3 248.2 343.4

Electricity bill cost

RMB$0.7/KWH

Lamp replacement

frequency (year) 0 1 1 1.5

T8 Magnetic Ballast Life:3,000hr

T8 Electronic Life:4,500hr

T5 Electronic Life:4,500hr

*LED Life(L70):.2,5000hrs

Annual lamp replacement

cost (RMB/year) 0 100 42 78

Cost: T8:RMB 13

T5:RMB 25

Electricity cost

+ lamp cost (RMB/year) 171.5 302.3 300 421.4 No included labor cost

Initial installation

cost (RMB/luminaire) 420 400 250

20

Demonstration

Page 21: V ! Advantages of Application of LEDs LIGHTING.pdf · 2009-02-26 · Specification V !30W 60W 100W Flood light. Input Voltage Correlated Color Temp. Operating Temp. Power Factor Beam

21

Part No. Series d(nm) CCT(K) Total Flux (lm) VWLB-CA3A02-12V Cool White - 5000-6500 120 VWLB-CA3W02-12V Warm White - 2700-3500 70 VWLB-CA3R02-12V Red 620-630 - 60 VWLB-CA3G02-12V Green 520-530 - 90 VWLB-CA3B02-12V Blue 460-470 - 20 VWLB-CA3K02-12V Yellow 585-595 - 60

Part No. Series d(nm) CCT(K) Total Flux (lm) VWLB-AA5A02-100-240V Cool White E27 5000-6500 200 VWLB-AA5W02-100-240V Warm White E27 2700-3500 150 VWLB-AB5A02-100-240V Cool White E14 5000-6500 200 VWLB-AB5W02-100-240V Warm White E14 2700-3500 150

Indoor Lighting Products.

Page 22: V ! Advantages of Application of LEDs LIGHTING.pdf · 2009-02-26 · Specification V !30W 60W 100W Flood light. Input Voltage Correlated Color Temp. Operating Temp. Power Factor Beam

22

Part No. Series CCT(K) Total Flux (lm) VAGS-DA01-5W57K-100-240V Cool White 5000-6500 400 VAGS-DA01-10W57K-100-240V Cool White 5000-6500 800

Part No. Series CCT(K) Total Flux (lm) VWLB-DA7A02-100-240V Cool White 5000-6500 400 VWLB-DA7W02-100-240V Warm White 2700-3500 280

Part No. Series CCT(K) Total Flux (lm) VWLB-FA12A02-100-240V Cool White 5000-6500 600 VWLB-FA12W02-100-240V Warm White 2700-3500 420

Page 23: V ! Advantages of Application of LEDs LIGHTING.pdf · 2009-02-26 · Specification V !30W 60W 100W Flood light. Input Voltage Correlated Color Temp. Operating Temp. Power Factor Beam

23

Underground and Wall Lights.

Cool White

Cool White

Cool White

Cool White

Warm White

Warm White

Warm White

Warm White

Yellow

Yellow

Yellow

Yellow

Red

Red

Red

Red

Green

Green

Green

Green

Blue

Blue

Blue

Blue

Page 24: V ! Advantages of Application of LEDs LIGHTING.pdf · 2009-02-26 · Specification V !30W 60W 100W Flood light. Input Voltage Correlated Color Temp. Operating Temp. Power Factor Beam

24


Recommended