    Swagelok ®

    VariableAreaFlowmeters

    © 2008 Swagelok Company

  • 8/17/2019 VAF Sales Ppt Resumed

    2/17

    Basic Components of aVAF

    VA Flowmeters

    Outlet

    Inlet

    Tapered Tube

    FloatScale

    MaximumMeasurement

    MinimumMeasurement

    Turndown Ratio = Max Measurement

    Min Measurement

    Turndown Ratio for VAFs = 10:1

    © 2008 Swagelok Company

  • 8/17/2019 VAF Sales Ppt Resumed

    3/17

    Advantages1. Visual indication of flow

    2. Do not require any external power

    3. Very low set-up cost

    4. Less expensive than most flowmeasurement technologies

    5. Simple and robust

    6. Minimal pressure drop

    VA Flowmeters

    © 2008 Swagelok Company

  • 8/17/2019 VAF Sales Ppt Resumed

    4/17

    G l as s t u b e m o d e l s

    Six models that vary in:– Size

    – Accuracy– Cost– Materials of construction

    GM G1 G2 G3 G4

    GP model is aplastic G2 model

    © 2008 Swagelok Company

    Swagelok G-Series

  • 8/17/2019 VAF Sales Ppt Resumed

    5/17

    Glass Tube – G1 Model– This G1 model is suitable for

    low flow rates in fine-meteringapplications such as gaschromatography.

    Features:

    Compact in size

    Accuracy class = 4.0

    Limit switches (one or two)

    © 2008 Swagelok Company

  • 8/17/2019 VAF Sales Ppt Resumed

    6/17

    Glass Tube – G2 Model– Commonly used in analytical

    instrumentation applications,the G2 model is appropriate forlow to medium flow rates.

    Features:

    Has the most flow ranges available;versatile

    Accuracy class = 2.5

    Limit switches (one or two)

    © 2008 Swagelok Company

  • 8/17/2019 VAF Sales Ppt Resumed

    7/17

    Glass Tube – G3 Model– The G3 model provides

    reliable, accuratemeasurement over the midranges of air or water flow.

    Features:

    Larger tube for easy reading

    Accuracy class = 2.5

    Limit switches (one or two)

    © 2008 Swagelok Company

  • 8/17/2019 VAF Sales Ppt Resumed

    8/17

    Glass Tube – G4 Model– Suitable for laboratory

    applications, the large-size G4model is highly accurate overits full measured flow range.

    Features:

    Most accurate flowmeter available

    Accuracy class = 1.0

    Limit switches (one or two)

    © 2008 Swagelok Company

  • 8/17/2019 VAF Sales Ppt Resumed

    9/17

    Glass Tube – GM Model– This miniature glass-tube

    model has a plastic head andfoot piece and can be panelmounted easily.

    Features:

    Very small and cost effective

    Accuracy class = 4.0

    No limit switches available on thismodel

    © 2008 Swagelok Company

  • 8/17/2019 VAF Sales Ppt Resumed

    10/17

    Glass Tube – GP Model– The GP model offers a plastic

    head and foot piece, includingend connections.

    Features:

    Many flow ranges available; costeffective option because of theplastic head and foot piece

    Accuracy class = 2.5

    Limit switches (one or two)

    © 2008 Swagelok Company

  • 8/17/2019 VAF Sales Ppt Resumed

    11/17

    M et a l tu b e o r a r m o r e d

    Four models that vary in:– Size

    – Accuracy– Cost– End connections– Orientation

    Models: M1 M2 M3

    MH model is ahorizontal M3 model

    © 2008 Swagelok Company

    Swagelok M-Series

  • 8/17/2019 VAF Sales Ppt Resumed

    12/17

    Metal Tube – M1 Model– The miniature M1 model is compact,

    yet offers protection against harshenvironments and higher pressureswith an armored measuring tube.

    Features:

    Compact size and lower price, while stilloffering the safety of the metal tube

    Accuracy class = 4.0

    Limit switches (min or max or both)

    © 2008 Swagelok Company

  • 8/17/2019 VAF Sales Ppt Resumed

    13/17

    Metal Tube – M2 Model– The M2 model offers versatility,

    with an integral junction box andchoice of mechanical or electronicdisplay.

    Features:

    Largest metal tube flowmeter withmetering valve. Also has optionalelectronic LED display.

    Accuracy class = 2.5

    Limit switches (min or max or both)

    Electronic version also provides 4 to 20mA output signal

    © 2008 Swagelok Company

  • 8/17/2019 VAF Sales Ppt Resumed

    14/17

    Metal Tube – M3 Model– This metal-tube flowmeter,

    with rugged design, is suitedfor extreme operatingconditions and high flow rates.

    Features:

    Large metal tube flowmeter withchoice of end connections, NPTor flange ends. Also availablewith ½ inch and 1 inch tubediameters.

    Accuracy class = 1.6

    Limit switches (min or max or both)4 to 20 mA output signal

    Has the most options available;configurable

    © 2008 Swagelok Company

  • 8/17/2019 VAF Sales Ppt Resumed

    15/17

    Metal Tube – MH Model– This horizontal model offers

    liquid flow reading left-to-rightor right-to-left to meet systemrequirements.

    Features:

    Only model available that can bemounted horizontally. Also

    available with ½ inch and 1 inchtube diameters.

    Accuracy class = 1.6

    Limit switches (min or max or both)

    4 to 20 mA output signalHas the most options available; very

    configurable

    © 2008 Swagelok Company

  • 8/17/2019 VAF Sales Ppt Resumed

    16/17

    Electronic Options• Limit Switches

    – There are electronic options that areavailable on most models to indicateif a flow is outside of a range that acustomer needs

    – A sensor will pick up where the floatis (above or below) and send outeither a 1 mA signal for below or a 3mA output for above

    – One (min or max) or two (min andmax) switches are available perflowmeter

    • 4 to 20 MA Output Signal– Is available on the M2, M3, and MH

    models– Produces an analog signal that is

    proportional to the flow on the scale,where 4 mA is the low reading and20 mA is the high reading

    Limit Switches

    Junction Box

    © 2008 Swagelok Company

  • 8/17/2019 VAF Sales Ppt Resumed

    17/17

    Additional Options• Junction Box – Recommended whenever switches are ordered• Threaded conduit gland• M20 X 1.5 cable gland• Valve Position – Can be switched to top position (liquids)• Certificate of compliance•

    5-Point pressure record• Pressure test and certificate• Material certification• Dye penetration test and certificate• X-ray test and report• Hardness test and report• Oil- and grease-free cleaning and test report

    Junction Box

    Valve would move totop position


Recommended