4/23/2013 1 Valves PRESSURE CONTROL VALVES Relief Simple compound Counterbalance Unloading Pressure reducing Protect actuators or Circuit reliefs Such as a external force acting on a cylinder when the valve is in neutral. Provide lower pressures Operate a circuit at a lower pressure than that of the system pressure. FORCE America Inc. RELIEF VALVES Simple Noisy, creates heat, high pressure override Compound Quiet, low pressure override Size Rate by GPM Location
Transcript
Page 1: Valves 2012 VMMC - Aventri · Counter Balance Valve Sequencing Valve P T A B M Load Load Sequence valve is set at 500 psi Pressur e Return Pressure Inlet FORCE America Inc. PRESSURE

4/23/2013

1

Valves

PRESSURE CONTROL VALVES

• Relief 

– Simple

– compound

• Counterbalance 

• Unloading

• Pressure reducing Protect actuators or Circuit reliefs

– Such as a external force acting on a cylinder when the valve is in neutral.

• Provide lower pressures 

– Operate a circuit at a lower pressure than that of the system pressure.

FORCE America Inc.

RELIEF VALVES

• Simple

– Noisy, creates heat, high pressure override

• Compound

– Quiet, low pressure override

• Size

– Rate by GPM

• Location

Page 2: Valves 2012 VMMC - Aventri · Counter Balance Valve Sequencing Valve P T A B M Load Load Sequence valve is set at 500 psi Pressur e Return Pressure Inlet FORCE America Inc. PRESSURE

4/23/2013

2

P               T

A                B

M

Relief Valves

Load

The relief is set at 1000 psi so it will  maintain that pressure   

Pressure

Return  Pressure

Inlet

FORCE America Inc.

Direct Acting Relief Valves

800 psi

Relief is set at 1000 psi

1000 psi

Relief is set at 1000 psi

Pilot Operated Relief

800 psi

20 psi spring

800 psi

980 psi spring

800 psi  + 20 psi spring = 820 psi so the valve stays seated

Pilot Operated Relief

1000 psi

20 psi spring

980 psi

980 psi spring

980 psi  + 20 psi spring = 1000 psi so the valve will lift

Page 3: Valves 2012 VMMC - Aventri · Counter Balance Valve Sequencing Valve P T A B M Load Load Sequence valve is set at 500 psi Pressur e Return Pressure Inlet FORCE America Inc. PRESSURE

4/23/2013

3

P               T

A                B

M

Load

Counter Balance Valve Sequencing Valve

P               T

A                B

M

Load

Load

Sequence valve is set at 500 psi

PressureReturn  Pressure

Inlet

FORCE America Inc.

PRESSURE REDUCING

• Reduce pressure in a sub circuit

• Designed to let components operate continuously at a lower pressure than the main relief

Pressure Reducing Valve

P               T

A                B

M

The relief is set at 1000 psi

The pressure reducing valve is set at  500 psi 

PressureReturn  Pressure

Inlet

Page 4: Valves 2012 VMMC - Aventri · Counter Balance Valve Sequencing Valve P T A B M Load Load Sequence valve is set at 500 psi Pressur e Return Pressure Inlet FORCE America Inc. PRESSURE

4/23/2013

4

FORCE America Inc.

UNLOADING VALVES

• High– low pump circuits

• Unloads high volume pump at a pre‐determined pressure

• Used in applications where a rapid extension of a cylinder is necessary at a low pressure

• High pressure pump unloads, the low volume high pressure pump takes over

Unloading Valve

5gpm

15gpm

M

Unlading valve is set at 500 psi

The relief is set at 2000 psi

PressureReturn  Pressure

Inlet

UNLOADER MID INLET UNLOADER INLET

Load sense signal to V40 section

Power core

Tank core/passageway

Load sense signal to V20 section

Power core

Pilot pressure for solenoid operated sections

Tank core/passageway

Page 5: Valves 2012 VMMC - Aventri · Counter Balance Valve Sequencing Valve P T A B M Load Load Sequence valve is set at 500 psi Pressur e Return Pressure Inlet FORCE America Inc. PRESSURE

4/23/2013

5

Directional Control Valve

Reservoir

EnginePump

Filter

Directional Control Valve

PressureReturn  Pressure

Inlet

FORCE America Inc.

DIRECTIONAL CONTROLS

• Operate actuators in a system

• Two types

• Monoblock

– Single casting, multiple spools

– Least expensive

– Limited to flow and pressure

– No circuit protection available

MONO BLOCK VALVE Sectional ValveSectional valves

•Wide variety of options•Different types of spool actuators

•Open or closed center applications•Power beyond capabilities

•Allowing fluid to be used down stream of valve

•Sections can be added •Load sensing•High flows and pressures available•Relief valves can be built into them

Page 6: Valves 2012 VMMC - Aventri · Counter Balance Valve Sequencing Valve P T A B M Load Load Sequence valve is set at 500 psi Pressur e Return Pressure Inlet FORCE America Inc. PRESSURE

4/23/2013

6

Add-A-Fold® Valve

Typical valve assembly

Shuttle valves, 

1 per section

Manual override connection

SPIN‐A‐VEYER SECTION

The valves have manual overrides which are the red knobs on the proportional coil, turning the red control knob clockwise will start the section to flow.

In‐line Check Valve Pilot Operated Check – Pilot to Open

M

Page 7: Valves 2012 VMMC - Aventri · Counter Balance Valve Sequencing Valve P T A B M Load Load Sequence valve is set at 500 psi Pressur e Return Pressure Inlet FORCE America Inc. PRESSURE

4/23/2013

7

The common practice is to use pilot operated to‐open check valves to hold static loads and to use counterbalance valves to hold dynamic loads. For example, aerial lifts include both the man lift boom as well as outriggers, which steady the lift frame. The outriggers, are held in position by pilot operated check valves while the man lift boom is commonly held in position by an over center valve. The boom is a dynamic load in that it is moved frequently, while the outriggers are set and remain stationary during operation of the aerial lift.

Pilot operated check valves (one way directional control valve)Pilot check valves will hold a load in position, but their operation is not as smooth as that of counterbalance valves in throttling the flow as the load is lowered. Pilot operated to‐open check valves do have the advantage of locking the load in position because the check valve has a positive seat, where spool type counterbalance valves will have some leakage. Both counterbalance valves and pilot operated to‐open check valves are mounted in or close to the cylinder port with rigid plumbing.

PILOT OPERATED CHECK VALVES

A single selector valve is used to operate two‐control valve from a single pump or two single acting cylinders with one directional control valve.

The multiple selector vales allow additional functions to be operated with a single pump source.

SELECTOR VALVES

A        P          B       T A        P          B       T

A        P          B       TA        P          B       T

Closed Center Float Center

Open Center Tandem Center

Valve Center Options

P       T

A       B

P       T

A       B

P       T

A       B

P       T

A       B

Parallel Circuit

100 psi

200 psi

300 psi

Page 157

Page 8: Valves 2012 VMMC - Aventri · Counter Balance Valve Sequencing Valve P T A B M Load Load Sequence valve is set at 500 psi Pressur e Return Pressure Inlet FORCE America Inc. PRESSURE

4/23/2013

8

Series Circuit

100 psi200 psi300 psi

Page 157

2 Stage Directional Controls

PA BT

2 Stage Directional Controls

PA BT

Energize the solenoid and the valve will shift

Page 9: Valves 2012 VMMC - Aventri · Counter Balance Valve Sequencing Valve P T A B M Load Load Sequence valve is set at 500 psi Pressur e Return Pressure Inlet FORCE America Inc. PRESSURE

4/23/2013

9

FORCE America Inc.

FLOW CONTROLS

• Designed to regulate the speed of a cylinder or motor

• Non compensated– Used in circuits where load pressure remains relatively constant and feed rates are not critical.  Any change in the workload would affect the flow or speed of an actuator. A needle valve or fixed orifice are examples of non compensated controls.

• Compensated– Adjust the flow as the load increases or decreases according to the induced load.  The flow will remain constant no matter what load does.

FORCE America Inc.

FLOW CONTROLS

• By‐pass type

– Maintains flow required by means of an adjustment, the unused fluid is diverted back to the reservoir

• Restrictor type

– Maintains flow of an actuator

– In‐line with the actuator

– Restricts the flow, unused flow is dumped over the relief valve

– Can cause high heat build up

FLOW CONTROLS• Designed to regulate the speed of a cylinder or motor

• Non compensated– Used in circuits where 

load pressure remains relatively constant and feed rates are not critical.  Any change in the workload would affect the flow or speed of an actuator. A needle valve or fixed orifice are examples of non compensated controls.

Non Compensated

Non Compensated with free flow check valve

Page 10: Valves 2012 VMMC - Aventri · Counter Balance Valve Sequencing Valve P T A B M Load Load Sequence valve is set at 500 psi Pressur e Return Pressure Inlet FORCE America Inc. PRESSURE

4/23/2013

10


Recommended