of 16
7/24/2019 varian modul
1/16
VarianAtomic AbsorptionSpectrometers
AA
7/24/2019 varian modul
2/16
Varians AA range enables analysts to extendthe performance and productivity boundariesof AA determinations, and is equally athome in routine laboratories where reliabilityand simple operation is vital.
The Varian AA range includes the stylishand easy-to-use AA280 and AA240 series.Combining Fast Sequential design with upto eight lamp capability, the AA240/280flame instruments provide high performanceand lower running costs. If you requiresuperior furnace performance and accurate
background correction, the AA280 Zeemaninstrument delivers, with fast transverseZeeman background correction and our newGTA120 graphite furnace. For an economicalanalysis solution, choose the AA240 series,which provides four lamp capacity and achoice of automation options.
AA choices for every applicationVarians wide range of hardware features,advanced software solutions and automationadvantages are designed to cater for everyapplication need. Select from:
Feature AA280FS AA280Z AA240FS AA240Z AA240 AA140
Fast Sequential capability
Dedicated furnace with Zeeman Correction
Full automation
PC control
Deuterium background operation
True double beam optics
Integrated accessories
Standard Feature
Optional Feature
Varian is synonymous with innovationand reliability in Atomic Absorption,and has over 50 years of comprehensiveexperience in analytical instrumentation.
A family of AA solutions
AA InnovationBuilt componentsfor worlds firstAAS (as Techtron)
1957Developedthe AA3,Techtrons firstcommercial AA
1964Nitrous-oxide/acetyleneburner introduced
1966Varian appliesfor a patent onZeemanbackgroundcorrection
1971Pioneeredgraphite furnacetechniques withthe transverseheated Model 61
1971Automated GFAanalyses withthe ASD-53 the first furnacautosampler
1977
7/24/2019 varian modul
3/16
ully automatedA-975 forulti-element
nalysis
981Introducedcentralizedinstrumentcontrol with theAA-30/40
1985DedicatedZeeman graphitefurnace AAS
1987Patented SIPSproviding onlinecalibration andfast online dilutionfor flame AA
1994Worksheetsoftware an innovativespreadsheetconcept fordata display
1995Patented FastSequential AASreduces analysistimes by upto 50%
1997Varians Duo AAintroducessimultaneousflame andfurnace analyses
2001
7/24/2019 varian modul
4/16
No matter what the application, Varian AA
systems deliver real productivityimprovements in flame AA. High productivitymeans reduced gas, reagent and lamp usage,and more results every day. Heres how:
Fast Sequential AAAchieve the productivity and speed ofsequential ICP with Varians patented FastSequential* AA systems. By measuring allelements in each sample before moving tothe next one, Varians Fast Sequential (FS)AA280 and AA240 provide complete resultsin minutes.
Determine your entire element suitewithout repeatedly aspirating samples
Improve productivity by up to 50% byreducing the sample analysis delays
Get full elemental coverage, no matterhow many elements you are determining
Reduce sample consumption withless delays throughout analysis, less sampleis wasted
Save labor and reduce running costs the more elements you determine,
the greater your savings
Improve precision and accuracy withonline internal standard corrections thiscorrects for physical differences, samplepreparation errors, or drift
How does Fast Sequential AA work?1. Determination time is optimized as theFS wizard sorts the elements by wavelengthand flame type
2. Optimum flame conditions are used foreach elemental determination the patentedHammer gas control** initiates instantaneouschanges to programmed flows and providessuperb reproducibility
3. Reproducible wavelength positioning isachieved with minimal delays by the highspeed wavelength drive (2,000 nm/min)operating under intelligent software control
4. Simultaneous operation of all lamps inFS mode
5. Fast lamp selection using a motordriven mirror
Real productivity improvements
Conventional AAdetermines only oneelement at a time,so samples are analyzedtime and time againduring a multi-elementsequence (top).
Using Fast Sequential AA,samples are onlyaspirated once and allelements are measuredbefore progressing tothe next sample (bottom).
* US patent no. 6,236,457** US patent no. 5,355,214
7/24/2019 varian modul
5/16
Flexible sample handling choices
If you deal with diverse samples, yourproductivity solution is Varians SamplePreparation Systems (SPS). The SPSautosamplers feature:
Fastest ever sample to sample changes
High sample capacity to enhancelaboratory productivity
Advanced rinse options to reducecarryover
Traveling Rinse: the most rapid rinseoption, which enables rinsing of the probe
as it is drawn up out of the sample.This enhances throughput by minimizingprobe movements
Flexible configuration with economicallaboratory racks for different tube typesand probes
Online dilution using the optionalbuilt-in diluter system
Complete sample preparation capabilityusing the optional diluter and software foroffline standard and sample preparation
Optional environmental enclosure forpurging/fume extraction
Varians latest
innovations for flame
autosampling include:
Pre-emptive sampling(top) Reduces analysis times
by an additional 15%
Reduces sample to
sample delays
Moves the autosampler
probe to the next
solution while the reading
is still in progress
Lowers sample
consumption the
reading is completed
using remaining
excess solution in the
transfer line
Smart Rinse(bottom) Optimizes rinse time
for each sample
Eliminates excessive
rinse times
Automatically extends
rinse times for those
solutions that need it
Eliminates carry over
as Smart Rinse monitorsthe wash-out until
minimum absorbance
reached
Reduces sample
analysis times
Simplifies method
development
-0.30
0.0
Abs
Time
Probewithdrawn
Probecontents
0.00
0.50
1.00
5.0 10.0 15.0
-0.30
0.0
Abs
Time
0.00
0.50
1.00
5.0 10.0 13.0
Rinsecommences
Rinseterminates
Min. absorbance setting
7/24/2019 varian modul
6/16
Productivity solutions for dilution and vapor generation
Fully automated hydride determinationswhen coupled with the SPS series SamplePreparation Systems
Increase sensitivity by 30% andimprove detection limits with the ETC-60Electrothermal Temperature Controller
Varians Sample Introduction Pump Systems
(SIPS) improve productivity with a rangeof unique benefits for flame AA.
No tedious, multiple standard preparation.Performs online multi point calibration froma single standard
Fast, online dilution of over range samples
No costly, time consuming manualdilution and re-analysis
Enhance accuracy and precision with< 2% error no more dilution errors
Varians dual pump SIPS-20 further reducessample preparation before analysis, with aunique range of productivity benefits.
Adds modifiers such as ionizationsuppressants online during analysis
Performs online spiking of samples forspike recovery studies
Automates the tedious task of flamestandard addition calibrations
Enhances accuracy and precision duringextended runs by enabling automated flame
internal standard correctionsVapor Generation made easyExtend analyses to trace levels with Varianscontinuous flow VGA-77. This allowsdeterminations of mercury and hydrideforming elements (As, Se, etc.) at part-per-billion (ppb) levels. The VGA-77 offers:
Convenience of flame AA operation
Better sensitivity than flow injection
Exceptional precisions of 1-2% RSDat ppb levels
High sample throughput of up to70 samples/hour
Simple operation, as the integral pumpprovides automatic reagent addition
Low sample consumption < 8 mL perelement during analysis
Reduced setup time and elimination crosscontamination when switching betweenelements with conflicting chemistries.Simply change modules
0.00
0.00
Abs
Cu mg/L
0.50
1.00
1.25
2.00 4.00 6.00 8.00 10.0
SIPS dilution performance
Actual M easured Dilution DilutionConc. mg/L Conc. mg/L Factor Error %
1.2 1.2 1.0 0.2
6.0 6.0 1.0 0.4
10.0 10.1 3.3 0.2
50.8 50.8 7.5 0.1
56.4 56.7 18.7 0.6
101.6 102.8 35.5 1.2
202.8 204.4 55.0 0.8
400.0 401.6 62.4 0.4
456.7 455.8 78.3 0.2500.0 497.2 138.4 0.6
500.0 501.3 151.8 0.3
7/24/2019 varian modul
7/16
Simultaneous AA operation
Duo systems double your AA productivity
The Varian AA Duo systems are theworlds only AA systems providing truesimultaneous operation of flame andgraphite furnace from a central computer.With an AA Duo, operation is more flexible,setup and change-over times are eliminatedand productivity is doubled.
Ideal for busy environmental, chemicalor industrial laboratories
Be more productive with simultaneousoperation of flame/hydride and graphite
furnace Customize the system to your needs bycombining flame or hydride atomizers witheither a deuterium or Zeeman correctedgraphite furnace
Centralize data and method storage inone location on the single controlling PC
Save time with dedicated atomizersthat eliminate complex setup and timeconsuming change-overs
Each atomizer is permanently aligned
for immediate use and never needsre-alignment
Analyze any sample with the widestlinear dynamic range from sub ppb(using furnace and hydride techniques)to percent levels (flame)
Simplify setup and operation withadvanced features such as automatedwavelength and slit selection
Fast Sequential technology provides theworlds fastest flame AA
Acclaimed worksheet software deliversrapid instrument setup, easy operationand simple method development
Varians range of accessories andautosamplers means the AA Duo systemcan develop with your needs
Varians Duo systemsprovide simultaneous
operation of flameand graphite furnaceatomizers from acentral computer,so you can doublethe productivity ofyour laboratory.
7/24/2019 varian modul
8/16
Superior furnace capabilities
Varians integrated GTA120 and Zeeman
GTA120 Graphite Tube Atomizers providesuperior furnace performance, no matterhow difficult the sample.
Constant Temperature Zone designVarian's superior furnace performanceis achieved via the Constant TemperatureZone (CTZ). The furnace power supply ismatched to low thermal mass, end heatedgraphite tubes with optimized wallthickness. This ensures rapid, controlledand even heating, creating a CTZ centredaround the injection hole. Benefits of the
CTZ design include: Extremely fast atomization even withdifficult sample matrices
Best signal-to-noise characteristics,due to the long atom cell. This ensures thebest detection limits and sensitivities
Excellent tube lifetimes and reducedmemory effects
Accurate temperature control from403000 C during both fixed and rampedtemperature stages without using
inaccurate optical temperature sensors Greater reproducibility, as heating ratesare software controlled to a maximum of2000 C/sec.
The GTA120:
Reduces running costs with extendedtube lifetimes and a 40% decrease in gasconsumption
Allows real time viewing of the injectionzone using the optional built-in Tube-CAM.You can also capture still images or video
the analysis Simplifies method development. Use Tube-CAM to accurately set the probe dispensingheight and confirm the optimum dryingand ashing temperatures
Provides extended capacity for up to 135solutions with the PSD120 ProgrammableSample Dispenser
Extends operation and reduce carouselchanges in laboratories with high sampleworkloads, using the high capacity carousel
Eliminates method development withthe SRM Wizard. This automatically
optimizes the furnace parameters andcreates a method utilizing therecommended conditions
Automates preparation of calibrationstandards and standard additions spikes,performs automatic over range volumereduction and utlizes flexible dispensingoptions such as hot inject or multi-injectwith the sophisticated sampling ofthe PSD120
Ensures reduced analytical cycle timesas the autosampler is synchronized with
furnace operation solutions are collectedwhile the furnace is in operation
Provides operator friendly fumeextraction during furnace operation usingthe optional fume extraction system
Provides flexible programming withup to 20 temperature steps and choice ofgas type and flow
Enables simple and rapid change-overfrom flame to furnace
The high capacitycarousel reduceschanges and can holdup to 135 solutions.
7/24/2019 varian modul
9/16
The ConstantTemperature Zoneensures a uniformtemperature profilealong the length ofthe tube, reducinginterferences andimproving accuracy.
Speed up methoddevelopment and getmore reliable resultsby using Tube-CAM tomonitor your analysisin real-time (left).
Extend tube lifetimesand reduce gasconsumption by 40%with the GTA120.Typical lifetimesfor an aqueouscopper standardwith an atomizationtemperature of2300 C are shown(above).
Simplify method
development for allusers using the powerfuland convenient SRMWizard. An optimizationstudy for Pb withphosphate modifieris shown.
0.000
Absorbance
ReplicatePrecision
Firings
Absorbance
0.05
0.10
0.15
0.20
0.25
0.30
0.35
0.40
0.45
0.50
0%
0.5%
1.0%
1.5%
2.0%
2.5%
3.0%
3.5%
4.0%
4.5%
5.0%
500 1000 1500 2000 2500 3000 3500 4000 4500 5000
Precision
0
10
500
1,000
1,500
2,000
2,500
3,000
ActualTemperature(deg.
C)
9 8 7 6 5 4 3 2 1 0 1 2 3 4 5 6 7 8 9 10
Distance from Tube Centre (mm)
Programmed 2450 Programmed 1800
7/24/2019 varian modul
10/16
The worlds best Zeeman AA
Varians patented Zeeman background
correction* enhances graphite furnacesystem performance with correction overthe full wavelength range for structuredbackground, spectral interferences and highbackground absorbances.
Outstanding performance at ppb levelsfrom the Constant Temperature Zonefurnace design
Easy alignment only a single light sourceis required
Most accurate correction with Varians
unique magnetic waveform providingdouble the background correction speed ofcompeting Longitudinal Zeeman instruments
Three point polynomial interpolationof the background signal ensures accuratebackground signal measurement
Polynomial interpolation provides up to an11-fold improvement in correction accuracyover competing systems using simple linearinterpolation (bracketing)
Flexibility to handle difficult samples
quickly and effectively. Optimum conditionsfor your analysis (drying, ashing andatomization temperatures, modifiers, injectionvolumes, etc.) can be rapidly developed usingthe SRM Wizard and Tube-CAM
Optimum conditions ensure highsensitivity and freedom from interferences.Competing systems may compromiseperformance by limiting elements or thewavelengths available for analysis, or evencompromising furnace conditions
Ultra trace level detection limits usingVarians high intensity UltrAA lamps, whichboost the emission intensity for reducednoise and enhance sensitivity
Simple plug-in capability for highperformance UltrAA lamps. No additionalpower supply is required
Zeeman backgroundcorrection has beenwidely accepted byinternational regulatoryagencies (such as theUS EPA) as the mosteffective backgroundcorrection technique.
Varian Zeemansystems have developeda reputation foroutstanding sensitivityand maximumperformance withchallenging samples.
* US patent no. 4,341,470
7/24/2019 varian modul
11/16
Achieving accurate Zeeman background correction
What is the Zeeman effect?The Zeeman effect is the splitting andpolarization of atomic spectral lines in thepresence of a magnetic field. The magneticfield has little effect on molecular speciesand particulates that can cause backgroundabsorption. The Zeeman technique usesthe magnetic field to achieve accuratebackground correction. With the magnet off,the total absorbance is measured. Once themagnetic field is applied to the atomizer,the spectral profile is split and only thebackground absorbance is measured.
The background absorbance (magnet on)is then subtracted from the totalabsorbance (magnet off) to determine theatomic absorbance.
Varians Zeeman solutionVarian Zeeman systems feature thetransverse AC modulated Zeemanconfiguration with the field applied acrossthe atomizer. This avoids the sensitivitylosses observed with a DC (permanent)magnet, and maximizes light throughoutcompared with longitudinal designs where
end caps restrict the light passing throughthe pole pieces of the magnet. Variansunique magnetic waveform provides adelay time of less than 5 ms betweenmeasurements and collects 100/120 datapoints every second (at 50/60 Hz).
The principle of the
transverse (AC) Zeemantechnique.
Magnet Off the totalabsorbance is measured.
Magnet On Zeemansplitting of the atomicabsorption profileoccurs and the polarizerexcludes the central picomponent. This allowsonly backgroundabsorbance to bemeasured at the exactanalytical wavelength.
A typical backgroundsignal is shown (black).Varians 100/120 Hzmodulation andpolynomial interpolationwith twice as manymeasurements providesimproved correction(red). Errors are muchhigher when usingconventional linearinterpolation(bracketing) at mainsfrequency (blue).
Varian Zeemansystems use threepoint polynomialinterpolations toaccurately track thebackground signal,resulting in an 11-foldimprovement incorrection accuracy.
Totalabsorbancesignal
Calculatedsignalinferior
Magnet on (Background abs)
Background tobe calculated atthis magnet offmeasurement
Magnet off (Total abs)
Linear Interpolation Procedure
Polynomial Interpolation Procedure
Totalabsorbancesignal
Magnet On (Background abs)
Background tobe calculated atthis magnet offmeasurement
Magnet Off (Total abs)
0 -0.030
BackgroundAbsorbance
AtomicAbsorbance
Time (ms)
-0.02
-0.01
0
0.01
0.02
0.03
2
50 100 150 200
7/24/2019 varian modul
12/16
Satisfying your analysis challenges
Every analysis presents its own challenges.
Tune performance to achieve the best,most accurate results as quickly as possiblewith Varians Mark 7 atomization system.No other system is as flexible or convenient.
Tune performance using the externallyadjustable impact bead
Achieve high sensitivity typically> 0.9 Abs. from 5 mg/L Cu
Optimize precision typical performanceis < 0.5% RSD from ten 5 secondintegrations
Mixing paddles provide a fine aerosol,extending operation with high dissolvedsolids solutions
Thorough mixing ensures precise, accuratedeterminations with reduced interferences
Efficient drainage eliminates spiking,
memory effects or long wash-out times,enabling higher sample throughput
Simple to use twist and lockassemblysimplifies routine maintenance
Corrosion-resistant components provideincreased durability
Minimal burner blockage is assured bythe contoured burner design. This providesoutstanding resistance to blockage, evenwith the most difficult samples
Compatibility with organic solvents simply fit organic resistant o-rings
The key components ofthe Mark 7 atomizationsystem the patented*nebulizer, spraychamber and burner are designed to givebest precision, efficientdrainage, minimalburner blockage and
reduced interferences.
* Australian patent no. 737783
7/24/2019 varian modul
13/16
Value added consumable products
Continue to benefit from the superior
performance of your Varian AA by selectingonly genuine Varian consumables.
Only Varian has the experience requiredto consistently produce high performancelamps. Since the development of Techtronsfirst range of hollow cathode lamps in the1960s, Varian has continued to researchand manufacture its own range of lamps.Varians extensive range includes single-element and solid-cathode multi-elementlamps, plus high-intensity UltrAA lampsfor superior cost-effective performance.Continuum lamps for background correctionsystems are also available.
Varian is committed to providing a fullrange of consumable products and suppliesat affordable prices, supported by superiorcustomer service. Call today to request yourfree copy of our comprehensive analyticalsupplies catalog. This features thousandsof products for GC, LC, MS, AA, ICP-OES,ICP-MS, UV-Vis-NIR, Fluorescence andSample Preparation from Varian and otherleading manufacturers. You can also shoponline at www.varianinc.com
Varian manufacturesits own range oflamps to guaranteeperformance and
reliability.
7/24/2019 varian modul
14/16
Our experience your advantage
Confirm data validity
Extensive rate and label driven QualityControl Protocols are provided to enable youto check precision, monitor QC standardsand more
Satisfy reporting requirements forinternational regulatory agencies using theoptional PRO software, which providesadditional QC capabilities
Customize the QC capabilities of the PROsoftware to suit your laboratorys QC systemusing the simple equation editor
Eliminate compliance headachesOptional SpectrAA CFR software helpsyou achieve compliance with the US FDA 21CFR 11 ruling, and provides:
Multi-level access with specific privilegesfor each user
Secure electronic records, full data audittrails and three levels of electronic signing(comment, review or final acceptance)
Certify instrument performance Certify performance of your instrument
using Varians Qualification services
Comprehensive qualification plansfor flame, furnace and vapor operationare available in Varians validationdocumentation
Automate OQ testing with minimal userinput using Varians AA Validate software
Ensure a secure audit record with thequalification test records
Qualification services can be included as
part of a comprehensive support agreement
Timely solutions for your support needs
Purchasing a Varian instrument isjust the beginning of our partnership.Enhance productivity, minimize downtimeand maximize the return on yourinvestment with Varians comprehensiverange of technical support services.
These include:
Direct access to technical expertsoperating our support hotlines in NorthAmerica and Europe*
Expert on-site support from our
worldwide network of highly skilled,factory trained customer servicerepresentatives
Online Telediagnostics support,enabling remote troubleshooting anddiagnosis at any location
On-site applications developmentand support
Classroom or customized on-sitetraining in your laboratory for both newand experienced users
Varians well established global networkof subsidiaries and representativesoffers complete sales, service, training,and applications support for our rangeof scientific instruments.
* Support hotlines may be available inselected other regions
Varianunderstands ourneeds andour business.The support fromVarian helps usto confidentlydeliver our resultsat the level our
customers expect.Doreen Fernandez,Laboratory OperationsManager, Agrifood Techno
7/24/2019 varian modul
15/16
Web integrated
The SpectrAA software links you directlyto all of Varians support resources.Use the Varian website www.varianinc.comto download applications and softwareupdates, shop online, track your orderstatus, view the latest product updates,or you can email us with your questions.
SafetyIt is Varians policy to manufacture safeproducts and to meet all legal requirementsgoverning the design, manufacture andsale of safe products. As with all similarproducts, the following hazards may bepresent: high temperatures, high pressuregases, explosive gases, UV and visible light,and electricity. Each product is designed toprotect operators from potential hazards.
Varian, Inc. supplies instructions thatdescribe the correct procedures for theoperation and maintenance of each product.
For clarity, some images in this brochuremay show the spectrometer operatingwithout safety covers. Ensure all safety
covers, chimney, etc. are in place fornormal operation.
Varian atomic absorption spectrometers aredesigned to determine the concentrationsof trace and major elements in solution.
Varian AA instruments arecertified to comply with therequirements of the EMC and
LV directives of the European Union.
Varian Zeeman AA instruments also complywith the guidelines established by the
International Commission on Non-IonizingRadiation Protection (ICNIRP) foroccupational exposure to time-varyingmagnetic fields.
Confirming Australias grain qualityAgrifood Technology, a worldwide leader in grain testing,rely on Varian AA and GC instruments to maintain theircompetitive edge. Agrifoods pride themselves on the qualityof their results and turnaround time. With thousands ofsamples to run, critical deadlines and instruments running upto 24/7, Agrifoods cannot wait days for service supportand cant service the growing demand for pesticide analysiswithout the right equipment.Varian service contracts providethem with cost effective solutions for both preventative
maintenance and urgent repairs.
7/24/2019 varian modul
16/16
Varian, Inc. is committedto a process of continuous
improvement which
demands that we
understand and then meet
or exceed the needs and
expectations of our
customersboth inside
and outside the company
in everything we do.
Varian, Inc. www.varianinc.com North America 800.926.3000, 1.925.939.2400
Europe The Netherlands 31.11.867.1000
Asia Pacific Australia 613.9560.7133
Latin America Brazil 55.11.3845.0444
China 86.21.6375.6969
Japan 81.3.5232.1239
Korea 82.2.3452.2452
Taiwan 886.22.698.9555
India 91.22.2431.3069
Other sales offices and dealers throughout the world
8510214700 5/04 Printed in Australia
Varian Sales and Dealer Offices
GC LC MS AAS ICP UV-Vis-NIR Fluorescence Dissolution NMR Consumable Products
Varian, Inc.
serving worldwide markets in:
Agriculture
Basic Chemical
Biotechnology
ClinicalElectronics
Environmental
Photonics
Toxicology
Pharmaceutical
Food and Beverage
Metals and Mining
Petroleum and Petrochemical
C E R T I F I E D
Q U A L I T Y S Y S T E M
All trademarks are the property
of their respective owners.
Specifications subject to change
without notice.