03309 rev. 06
Installer Manual
Ventilation systems for residential use only
Duo 1.2 (part no. 43710)
Duo 1.4 (part no. 43700)
Duo 1.9 (part no. 45700)
Solo 1.5* (part nos 43720 and 43725)
Solo 2.0 (part nos 45720 and 45725)
VB0092
VB0093
* This product earned the ENERGY STAR® by meeting strict energy efficiency guidelines set by Natural Resources Canada and the US EPA. It meets ENERGY STAR requirementsonly when used in Canada.
2
Table of Contents
1. REFERENCES........................................................................................3
2. SERVICE ..............................................................................................42.1 3-D Drawing ..................................................................................................42.2 Parts Ordering Chart ....................................................................................52.3 Technical Support ..........................................................................................5
3. SIZING ................................................................................................6
4. UNIT TYPE & DEFROST SETTING VS GEOGRAPHICAL LOCATION ................7
5. TECHNICAL DATA ................................................................................................85.1 Air Distribution (Normal Operation) ..............................................................85.2 Air Distribution (Defrost and/or Filtration Mode)............................................85.3 Defrost Cycles Tables ....................................................................................85.4 Dimensions....................................................................................................95.5 Controls and Link Options ............................................................................95.6 Specifications ................................................................................................9
6. TYPICAL INSTALLATIONS........................................................................106.1 Fully Ducted System ..................................................................................106.2 Exhaust Ducted System (Source Point Ventilation) ....................................106.3 Simplified (Volume Ventilation) ....................................................................10
7. INSTALLATION ................................................................................11-167.1 Locating and Mounting the Unit ..................................................................117.2 Planning of the Ductwork ............................................................................117.3 Calculating the Duct Size ............................................................................12
7.3.1 Example Calculation..........................................................................127.3.2 Example of a Design for a Fully Ducted System ..............................12
7.4 Installing the Ductwork and Registers....................................................13-147.4.1 Fully Ducted System ........................................................................137.4.2 Exhaust Ducted System (Source Point Ventilation) ..........................137.4.3 Simplified Installation (Volume Ventilation)........................................14
7.5 Connecting the Duct to the Unit ..................................................................157.6 Installing the Exterior Hoods ......................................................................167.7 Connecting the Drain (Solo only) ................................................................16
8. CONTROL DEVICES ........................................................................17-188.1 Main Controls ..............................................................................................178.2 Optional Controls ........................................................................................178.3 Other Features ............................................................................................18
3
Table of Contents (cont’d)
About this Manual
9. INSTALLATION OF THE CONTROLS ....................................................18-229.1 Dimensions and Specifications ................................................................189.2 Installation of the Main Control ............................................................19-21
9.2.1 Altitude Main Control Installation ........................................................199.2.2 Deco-Touch Main Control Installation ..................................................209.2.3 Venta Main Control Installation ............................................................209.2.4 Main Control Electrical Connection......................................................21
9.3 Optional Controls Electrical Connection ..................................................219.4 Electrical Connection to the Furnace........................................................229.5 Furnace Interlock Types............................................................................22
10. WIRING DIAGRAMS ........................................................................23-24
11. AIR FLOW BALANCING ........................................................................25
12. OVERALL VERIFICATION........................................................................2611.1 Main Controls ............................................................................................2611.2 Optional Controls ......................................................................................26
13. MAINTENANCE / INSTRUCTIONS FOR USER ............................................27
14. TROUBLESHOOTING ........................................................................27-28
This manual uses the following symbols to emphasize particular information:
NOTE: Indicates supplementary information needed to fully complete an instruction.
WARNINGIdentifies an instruction which, if not followed, might cause serious personal injuries includingpossibility of death.
!
CAUTIONDenotes an instruction which, if not followed, may severely damage the unit and/or its components.
1. References
R 2000 Venmar QualityAssurance
• HVI, “Installation Manual for Heat Recovery Ventilators”, 1987 edition.
• ASHRAE 1984 Systems Handbook, chapter 11, “Air Distribution Design for Small Heating and Cooling Systems”.
4
2.1 3-D DRAWING
2. Service
2616
1618
17
2122
23
24
25
VL0
040
1
2
3
5
4
6
810 3 11
12
13
9
15
14
8
7
1719
8
20
Uni
t sh
own
in n
orm
al p
ositi
on.
5
2.2 PARTS ORDERING CHART
2. Service (cont’d)
TO ORDER PARTS: Contact your local distributor.
No. Description SOLO 1.5 SOLO 2.0 DUO 1.2 DUO 1.4 DUO 1.9(A) 43720 (A) 45720 43710 43700 45700(B) 43725 (B) 45725
1 Double Collar Port no. 2 02257 02257 02257 02257 022572 Damper no. 1 (kit) 12454 12454 12454 12454 124543 Damper Rod (kit) 13037 13037 13037 13037 130374 Electronic Board & spacers (kit) 13038 13038 13039 13039 130395 Thermistor (kit) 12895 12895 12895 12895 12895
6 Door Latches & screws 00886 (2) 00886 (2) 00886 (2) 00886 (2) 00886 (2)00601 (4) 00601 (4) 00601 (4) 00601 (4) 00601 (4)
7 Damper Actuator Assembly 13734 13734 13734 13734 137348 Basic Filter 03308 03308 03308 03308 033089 Blower Assembly 12908 12912 12909 12909 1291110 Square Damper (kit) 13033 13033 13033 13033 1303311 Top Wheel 02238 02238 02238 02239 0223912 Motor 12109 12157 12109 12109 1215713 Bottom Wheel 02240 02240 02239 02239 0224014 Door Ass’y (including 15 & 16) 13346 13346 13346 13346 1334615 Door Latches (keeper) 00887 (2) 00887 (2) 00887 (2) 00887 (2) 00887 (2)
& Screws 00601 (4) 00601 (4) 00601 (4) 00601 (4) 00601 (4)16 Hinge Ass’y (kit) 13036 13036 13036 13036 13036
Pleated Optional Filter 03316 03316 03316 03316 03316 17 Charcoal Optional Filter 03315 03315 03315 03315 03315
Electronic Optional Filter 03314 03314 03314 03314 03314
18 12’’ Cassette (incl. motor) N/A N/A - 15184 -14’’ Cassette (incl. motor) N/A N/A 15185 - 15185
19 Recovery Core (A) 03322 (A) 03322 N/A N/A N/A(B) 03311 (B) 03311
20 Small Basic Filter* 09300 09300 N/A N/A N/A21 Balancing Double Collar Port 02256 02256 02256 02256 0225622 Balancing Damper 02253 02253 02253 02253 0225323 Snap Bushing DP-750 03324 (2) 03324 (2) 03324 (2) 03324 (2) 03324 (2)
& O-Ring 03310 (4) 03310 (4) 03310 (4) 03310 (4) 03310 (4)24 Drain Connector (kit) 03203 03203 N/A N/A N/A25 Door Switch (SPST), E69 10A 01825 01825 01825 01825 01825
26 Media (14’’ Wheel) N/A N/A 15186 - 15186Media (12’’ Wheel) N/A N/A - 15187 -
Please take note that parts not listed are not available; those parts require assembly knowledge that only manufacturer can guarantee.* On Solo units only, if an optinal filter is installed, discard the small basic filter.
For assistance, call on weekdays, 8:30 AM to 5:00 PM (Eastern Standard Time).NOTE: Do not call this number for ordering parts.
Canada & U.S.A.: 1-800-649-0372 (toll free)
2.3 TECHNICAL SUPPORT (FOR ASSISTANCE)
REPLACEMENT PARTS AND REPAIR
In order to ensure your ventilation unit remains in good working condition, you must use Venmar Ventilation Inc. genuinereplacement parts only. The Venmar Ventilation Inc. genuine replacement parts are specially designed for each unit andare manufactured to comply with all the applicable certification standards and maintain a high standard of safety. Anythird party replacement part used may cause serious damage and drastically reduce the performance level of your unit,which will result in premature failing. Also, Venmar Ventilation Inc. recommends to contact a certified service depot forall replacement parts and repairs.
6
These are the two most common methods used to evaluate the ventilation needs of a house:
CSA F326 and Canadian Building Code:• High speed: 10 cfm per room
20 cfm for the master bedroom and the basement
• Low speed: 40-60% of high speed
ASHRAE Standard 62-2001:• 0.35 air change per hour
Refer to ventilation code of your area to determine which method to use.
Example:
3. Sizing
Masterbedroom
Bedroom no.1
Kitchen
Basement
Bedroomno. 2
Bedroom no. 3
Living room Bat
hroo
mno
. 3
Dining room
VH0021A
Family room
Bat
hroo
mno
. 1
Bat
hroo
mno
. 2 Laundry room
1320 ft²1320 ft²
CSA F326
Kitchen (10 cfm)Dining room (10 cfm)Living room (10 cfm)Family room (10 cfm)Master bedroom (20 cfm)Bedroom no. 1 (10 cfm)Bedroom no. 2 (10 cfm)Bedroom no. 3 (10 cfm)Bathroom no. 1 (10 cfm)Bathroom no. 2 (10 cfm)Bathroom no. 3 (10 cfm)Laundry room (10 cfm)Basement (20 cfm)
Total 150 cfm
ASHRAE Standard 62-1989
Volume of basement 10560 ft³Volume of main floor 10560 ft³Volume of second floor 10560 ft³
Total volume 31680 ft³x 0.35/h
11090 ft³/h÷ 60 (min/h)
Total 185 cfm
1320 ft²
Second floor Main floor
Basement
7
4. Unit Type & Defrost Setting vs Geographical Location
HO
RA
GE
WH
ITE
HO
RS
E
JUN
EA
U
HAY
RIV
ER
YE
LLO
WK
NIF
E
PR
INC
E R
UP
ER
TG
RA
ND
E P
RA
IRIE
FO
RT
MC
MU
RR
AY
ZO
NE
A
FO
RT
SM
ITH
ED
MO
NTO
NP
RIN
CE
ALB
ER
T
SA
SK
ATO
ON
JAS
PE
R
KA
MLO
OP
SC
ALG
AR
Y
PE
NT
ICTO
NR
EG
INA
LET
HB
RID
GE
HE
LEN
A
VIC
TOR
IA
OLY
MP
IA
WIN
NIP
EG
SA
LEM
BO
ISE
BIS
MA
RC
K
SA
LT L
AK
E C
ITY
SA
ULT
ST
E M
AR
IE
ST.
PA
UL
DE
S M
OIN
ES
MA
DIS
ON
TIM
MIN
S
HA
RR
ISB
UR
G
SA
CR
AM
EN
TO
DE
NV
ER
TOP
EK
A
SU
DB
UR
Y
TOR
ON
TO
DE
TR
OIT
IND
IAN
AP
OLI
S
SA
NTA
FE
SP
RIN
GF
IELD
OK
LAH
OM
A C
ITY
PH
OE
NIX
CO
LUM
BU
S
NA
SH
VIL
LE
ATLA
NTA
BÂ
TON
RO
UG
EA
US
TIN
CO
LUM
BIA
RA
LEIG
H
WA
SH
ING
TON
OT
TAW
A
NO
RT
H B
AY
VA
L-D
ORC
HIC
OU
TIM
I
HA
RT
FO
RD
CH
IBO
UG
AM
AU
MO
NT
RÉ
ALQ
UÉ
BE
C
BO
STO
N
GO
OS
E B
AY
LAB
RA
DO
R C
ITY
SE
PT-
ILE
S
MAT
AN
E
GA
SP
É
BAT
HU
RS
T
ST-
JOH
NH
ALI
FAX
CH
AR
LOT
TE
TOW
N
ST
JO
ZO
NE
C
ZO
NE
B
RE
NO
VN
0001
ZONE
A
Solo
is re
com
men
ded.
Set
:”ex
tend
ed d
efro
st”
acco
rdin
g to
Sec
tion
10.
ZONE
B
Solo
is re
com
men
ded
but i
f a D
uo u
nit i
s us
ed, i
t has
tobe
ove
rsize
d (b
ecau
se o
f its
hig
h hu
mid
ity tr
ansf
er e
fficie
ncy)
.Se
t “ex
tend
ed d
efro
st” a
ccor
ding
to S
ectio
n 10
.
ZONE
C
Solo
or D
uo (a
ny m
odel
s). “
Exte
nded
def
rost
” not
requ
ired
(fact
ory
defro
st s
trate
gy p
re-s
et).
SY
MP
TOM
SO
LUT
ION
(con
dens
atio
n)
Indo
or a
ir qu
ality
pro
blem
DU
O
and
/ or
Exc
ess
moi
stur
e pr
oble
mD
UO
and/
orIm
port
ant e
xces
s m
oist
ure
prob
lem
SOLO
VQ
0013
ZONE
B &
C S
ELEC
TIO
N CH
ART
NO
RT
H A
ME
RIC
A
VF0019VF0018
VF0017
8
5.1 AIR DISTRIBUTION (NORMAL OPERATION)
5.2 AIR DISTRIBUTION (DEFROST AND/OR FILTRATION MODE)
5. Technical Data
VF0016 SOLO DUO
STALE AIR FROM BUILDING
SOLO FILTERED AIR TO BUILDING
DUO
FRESH AIR FROM OUTSIDE
STALE AIR FROM BUILDING
FRESH AIR FROM OUTSIDE
FRESH AIR TO BUILDING
STALE AIR TO OUTSIDE
FRESH AIR TO BUILDING
STALE AIR TO OUTSIDE
STALE AIR FROM BUILDING
FILTERED AIR TO BUILDING
STALE AIR FROM BUILDING
SOLO units
DUO units
Celcius (°C)
-5-15-27
Fahrenheit (°F)
235
-17
Defrosting (min.)
666
Operation time (min.)between each defrost cycle
603220
Defrosting (min.)
101010
Operation time (min.)between each defrost cycle
302015
Outside Temperature Defrost Cycles Extended Defrost Cycles
Celcius (°C)
-5-15-27
Fahrenheit (°F)
235
-17
Defrosting (min.)
999
Operation time (min.)between each defrost cycle
603220
Defrosting (min.)
101010
Operation time (min.)between each defrost cycle
302015
Outside Temperature Defrost Cycles Extended Defrost Cycles
NOTE: THE SOLO AND DUO PERFORMANCE CHARTS ARE LISTED ON THE SPECIFICATION SHEETS OF THESE UNITS. VISIT OUR WEBSITE AT WWW.VENMAR.CA TO ACCESS THOSE DOCUMENTS.
5.3 DEFROST CYCLES TABLES
9
5. Technical Data (cont’d)
Main controls:• Altitude• Deco-Touch• Venta
Optional controls:• 20/40/60-minute push-button timer• 60-minute crank timer• Dehumidistat
Link option:• Furnace interlock
(used with forced air systems)
5.5 CONTROLS AND LINK OPTIONS
5.6 SPECIFICATIONS
16½”(419 mm)
17 /8” (435 mm)30¼” (768 mm)6” (152 mm)
VK0029A
1
5.4 DIMENSIONS
Model Solo 1.5 Solo 2.0 Duo 1.2 Duo 1.4 Duo 1.9
Weight 65 lb (29.5 kg) 67 lb (30.4 kg) 71 lb (32.2 kg) 71 lb (32.2 kg) 73 lb (33.1 kg)
Port Diameter 6” (152 mm) 6” (152 mm) 6” (152 mm) 6” (152 mm) 6” (152 mm)
Drain Diameter 1/2” (12 mm) 1/2” (12 mm) N/A N/A N/A
Installation Chains and springs (provided with the unit).
Motor Speed High and low speed factory set (optional increased or decreased low speed)
Electrical supply 120 V, 60 Hz 120 V, 60 Hz 120 V, 60 Hz 120 V, 60 Hz 120 V, 60 Hz
Power Consumption 150 watts 240 watts 160 watts 160 watts 250 watts
10
6. Typical Installations
(Primarily for homes with radiant hot water or electric baseboard heating. See figure 1.)
Moist, stale air is exhausted from the high humidity areas inthe home, such as bathrooms, kitchen and laundry room.Fresh air is supplied to bedrooms and principal living areas.
If required, bathroom fans and a range hood may be used tobetter exhaust stale air.
Homes with more than one level require at least one exhaustregister at the highest level.
6.1 FULLY DUCTED SYSTEM
There are three (3) common installation methods.
VH0002
*Installations may vary according to the model number and the position (normal or reverse) inwhich the unit is installed.
figure 1
See 7.4.1 for details
6.2 EXHAUST DUCTED SYSTEM (SOURCE POINT VENTILATION)
(For homes with forced air heating. See figure 2.)
Moist, stale air is exhausted from the high humidity areasin the home, such as bathrooms, kitchen and laundryroom. Fresh air is supplied to the cold air return or the supply duct of the furnace. If required, bathroom fans anda range hood may be used to better exhaust stale air.
Homes with more than one level require at least oneexhaust register at the highest level.NOTE: For this type of installation, it is not essential
that the furnace blower runs when the unit is in operation, but we recommend it.
VH0006
See 7.4.2 for details
figure 2
6.3 SIMPLIFIED (VOLUME VENTILATION)
(For homes with forced air heating. See figure 3.)
Fresh air and exhaust air flow through the furnace ductswhich simplifies the installation.
The use of bathroom fans and a range hood is suggested toexhaust stale air.
NOTE: For this type of installation, the furnace blower should be running when the unit is in operation.
VH0007figure 3
See 7.4.3 for details
7.2 PLANNING OF THE DUCTWORK
11
7. Installation
INSPECT THE CONTENTS OF THE BOX
• Inspect the exterior of the unit for shipping damage. Ensure that there is no damage to the door, door latches,door hinges, dampers, duct collars, cabinet, etc.
• Inspect the interior of the unit for damage. Ensure that the fan motor assembly, recovery module, insulation,dampers, damper actuator and condensation tray (Solo) are all intact.
• If the unit was damaged during shipping, contact your local distributor. (Claim must be made within 24 hours afterdelivery.)
• Use checklist included with the unit to ensure that no parts are missing.
7.1 LOCATING AND MOUNTING THE UNIT
NOTE: Please note that the unit can be installed in either the “normal” or “reverse” (upside down) position.Choose an appropriate location for the unit:• Within an area of the house where the temperature is kept above 10°C / 50°F
and below 40°C/104°F.• Away from living areas (dining room, living room, bedroom), if possible.• So as to provide easy access to the interior cabinet for every three months and
annual maintenance, and to the control panel on the side of the unit.• Close to an exterior wall, so as to limit the length of the insulated flexible duct to
and from the unit.• Close to a drain. If no drain is close by, use a pail to collect run-off.
(Solo models only.)• Away from hot chimneys, electrical panel and other fire hazards.
• Allow for a power source (standard outlet).
Hang the unit with the 4 chains and springs provided (see figures 4 and 5).
VD0037
VD0038
VD0039A
1/8”(3 mm)
figure 4
figure 5
figure 6
CAUTIONMake sure the unit is level, with a 1/8’’ (3 mm) tilt backwards (seefigure 6).
a) Follow the instructions in Section 6.3 next page to determine the appropriate duct diameters for your system.
b) Keep it simple. Plan for a minimum number of bends and joints. Keep the length of insulated duct to a minimum.
c) Do not use wall cavities as ducts. Do not use branch lines smaller than 4” Ø (102 mm Ø).
d) Do not ventilate crawl spaces or cold rooms. Do not attempt to recover the exhaust air from a dryer or a rangehood. This would cause clogging of the recovery module. Use sheet metal for the kitchen exhaust duct.
e) Be sure to plan for at least one exhaust register on the highest lived-in level of the house if it has 2 floors or more.
WARNINGWhen performing installation, servicing or cleaning the unit, it is recommended to wear safetyglasses and gloves.
!
WARNING!When applicable local regulation comprises more restrictive installation and/or certificationrequirements, the aforementioned requirements prevail on those of this document and theinstaller agrees to conform to these at his own expenses.
12
7. Installation (cont’d)
Use the table below to ensure that the ducts you intend to install will be carrying air flows at or under the recommended values. Avoid installing ducts that will have to carry air flows near the maximum values andnever install a duct if its air flow exceeds the maximum value.
NOTE: Examples 7.3.1 and 7.3.2 use imperial measures. The same calculation applies to metric measures.
7.3.1 Example of calculation:Problem: My installation requires two exhaust registers (one for the kitchen, one for the bathroom). I will connect these registers to a main duct which will connect to the unit (high speed performance value of 140 cfm). What size of duct should I use for the main exhaust duct and for the two end branches leading to the registers? (See figure 7.)Solution: Simplified method. (For a more detailed method of calculating duct size refer to the ASHRAE or HRAI HANDBOOK).Main duct: Table above indicates a 6” Ø duct: Recommended air flow: 120 cfm; maximum air flow: 180 cfm.The high speed air flow of 140 cfm is close enough to the recommended value (120) and far enough away from the maximum value (180). Therefore a 6” Ø duct or larger is an appropriate choice for the main exhaustduct.End branches: Each end branch will have to transport an air flow of 70 cfm (140 divided by 2). Table above indicates a 5” Ø duct: Recommended air flow: 75 cfm; maximum air flow: 110 cfm. The high speed air flow of 70 cfm is close enough to the recommended value (75) and far enough away from the maximum value (110). Therefore a 5” Ø duct or larger is an appropriate choice for the 2 end branches.NOTE: A 4” Ø duct would have been too small because the maximum acceptable value for a 4” Ø
duct is 60 cfm.
7.3 CALCULATING THE DUCT SIZE
7.3.2 Example of a design for a fully ducted system for a unit having a high speed performance of 222 cfm (see figure 8).
VI0004
4” Ø42 cfm
6” Ø 129 cfm
5” Ø65 cfm
5” Ø 64 cfm
6” Ø 93 cfm
5”
6”
7” 7”6”
6”6”
4”
4”
4”4”
4” Ø 42 cfm
6” Ø 84 cfm6” Ø 96 cfm
6” Ø 138 cfm
figure 87” Ø 222 cfm
7” Ø 222 cfm
VI0003
END
BRANCHES
MAIN BRANCH
6ӯ 140 CFM
5ӯ
70 CFM
figure 7
DuctDiameter
Recommended Air Flow Maximum Air Flow
4” (102 mm) 40 cfm 19 l/s 68 m³/h 60 cfm 28 l/s 102 m³/h
5” (127 mm) 75 cfm 35 l/s 127 m³/h 110 cfm 52 l/s 187 m³/h
6” (152 mm) 120 cfm 57 l/s 204 m³/h 180 cfm 85 l/s 306 m³/h
7” (178 mm) 185 cfm 87 l/s 314 m³/h 270 cfm 127 l/s 459 m³/h
8” (203 mm) 260 cfm 123 l/s 442 m³/h 380 cfm 179 l/s 645 m³/h
13
7. Installation (cont’d)
7.4 INSTALLING THE DUCTWORK AND REGISTERS
WARNINGNever install a stale air exhaust register in a room where there is a combustion device, such as agas furnace, a gas water heater or a fireplace.
!
7.4.1 Fully Ducted System (as illustrated in Section 6.1)
Stale air exhaust ductwork:• Install registers in areas where contaminants are produced: Kitchen, bathrooms, laundry room, etc.• Install registers 6 to 12 inches (152 to 305 mm) from the ceiling on an interior wall OR install them in
the ceiling.• Install the kitchen register at least 4 feet (1.2 m) from the range.• If possible, measure the velocity of the air flowing through the registers. If the velocity is higher
than 400 ft/min. (122 m/min), then the register type is too small. Replace with a larger one.
Fresh air distribution ductwork:• Install registers in bedrooms, dining room, living room and basement.• Install registers either in the ceiling or high on the walls with air flow directed towards the ceiling.
(The cooler air will then cross the upper part of the room, and mix with room air before descending tooccupant level.)
• If a register must be floor installed, direct the air flow up the wall.
7.4.2 Exhaust Ducted System (Source Point Ventilation) (as illustrated in Section 6.2)
Stale air exhaust ductwork: (same as for Fully Ducted System, described on point 7.4.1)
Fresh air distribution:
There are two methods for connecting the unit to the furnace:
Method 1: Supply side connection• Cut an opening into the furnace supply duct at least
18 inches (0.5 m) from the furnace.• Connect this opening to the fresh air distribution port of the
HRV/ERV (use metal duct, see figure 9).• Make sure that the HRV/ERV duct forms an elbow inside the
furnace ductwork.• If desired, interlock (synchronize) the furnace blower opera-
tion with the HRV/ERV operation. (See Section 9.3).
Method 2: Return side connection• Cut an opening into the furnace return duct not less than
10 feet (3.1m) from the furnace (A+B).• Connect this opening to the fresh air distribution port of the
HRV/ERV (see figure 10).NOTE: For Method 2, it is not essential that the furnace
blower runs when the unit is in operation, but we recommend it. If desired, synchronize the furnace blower operation with the HRV/ERV operation.(See Section 9.3).
WARNINGWhen performing duct connection to the furnace, installation must be done in accordance withall applicable codes and standards. Please refer to your local building code.
CAUTIONWhen performing duct connection to the furnace supply duct, this duct must be sized to support theadditional airflow produced by the ERV/HRV. Also, use a metal duct. It is recommended that theERV/HRV is running when the furnace is in operation in order to prevent backdrafting inside ERV/HRV.
!
VD0172
Minimum18” (0.5 m)
Metal duct
figure 9
B
A
VD0108 A+B = not lessthan 10’ (3.1 m) figure 10
CAUTIONThe ductwork is intended to be installed in compliance with all local and national codes that are applicable.
14
7. Installation (cont’d)
7.4.3 Simplified installation (Volume Ventilation) (as illustrated in Section 6.3)
There are two methods (figures 11 and 12) for connecting the unit to the furnace:
Method 1: return-supply Method 2: return-return
Stale air intake:• Cut an opening into the furnace return duct (not less than 10 feet (3.1 m) from the furnace).• Connect this opening to the stale air intake port on the HRV/ERV as shown.
Fresh air distribution: (same instructions as for Method 1 or Method 2, Section 7.4.2).
For Method 2 (return-return) make sure there is a distance of at least 3 feet (0.9 m) between the 2 connections to the furnace.NOTE: For Method 1, it is not essential to synchronize the furnace blower operation with the unit operation,
but we recommend it.
7.4 INSTALLING THE DUCTWORK AND REGISTERS (CONT’D)
B
A
VD0171
B
A
VD0111
Minimum 3’(0.9 m)
Metal duct
Minimum 18”(0.5 m)
figure 12figure 11
CAUTIONIf using Method 2, make sure the furnace blower operation is synchronized with the unit operation!See Section 9.3.
WARNINGWhen performing duct connection to the furnace, installation must be done in accordance withall applicable codes and standards. Please refer to your local building code.
!
A+B = not lessthan 10’ (3.1 m)
A+B = not lessthan 10’ (3.1 m)
CAUTIONWhen performing duct connection to the furnace ducts (Method 1), these ducts must be sized tosupport the additional airflow produced by the ERV/HRV. Also, the supply duct must be a metalduct. It is recommended that the ERV/HRV is running when the furnace is in operation in order toprevent backdrafting inside ERV/HRV.
15
7. Installation (cont’d)
Insulated flexible ductUse the following procedure for connecting the insulated flexible duct to the ports on the unit (exhaust to outside andfresh air from outside).
a) Pull back the insulation to expose the flexible duct.b) Connect the interior flexible duct to the port using a duct tie.c) Carefully seal the connection with duct tape.d) Pull the insulation over the joint and tuck it between the inner and outer rings of the double collar.e) Pull the vapor barrier over the insulation and over the outer ring of the double collar.f) Apply duct tape to the joint making an airtight seal. Avoid compressing the insulation when you pull the tape tightly
around the joint. Compressed insulation loses its R value and causes water dripping due to condensation on theexterior surface of the duct.
a) b) c) d), e) f)
Rigid ductUse duct tape to connect the rigid ducts to the ports.
Make sure that the 2 balancing dampers are left in a fully open position before connecting the ducts to these ports(fresh air distribution port and stale air exhaust port as shown on figure 13).
7.5 CONNECTING THE DUCTS TO THE UNIT
CAUTIONMake sure that the vapor barrier on the insulated ducts does not tear during installation to avoidcondensation within the duct.
CAUTIONDo not use screws to connect rigid ducts to the ports.
VJ0007
figure 13
VJ0001VJ0002 VJ0003 VJ0004 VJ0005
16
7. Installation (cont’d)
7.6 INSTALLING THE EXTERIOR HOODS
Choose an appropriate location for installing the exteriorhoods:• at a minimum distance of 6 feet (1.8 m) between the
hoods to avoid cross-contamination• at a minimum distance of 18 inches (457 mm) from the
ground
Refer to figure 14 for connecting the insulated duct to thehoods. Place the “FRESH AIR INTAKE” sticker, provided inthe installation kit, on corresponding hood. An “Anti-GustIntake Hood” should be installed in regions where a lot ofsnow is expected to fall.
VD0028
EXHAUST
HOOD
OPTIONAL DUCT
LOCATIONTAPE AND DUCT TIE
CAULKING
INTAKE
HOOD
6” Ø(152 MM)
18” (457 MM)
18” (457 MM)
6’ (1.8 M) 6’
(1.8 M)
18” (457 MM)
figure 14
VO0010
7.7 CONNECTING THE DRAIN (SOLO ONLY)
VO0008
VO0011 TO DRAIN
To install the drain fittings, punchthe 2 knock-out sections located atthe bottom of the unit.
In order to keep the drain pan intact,hand tighten the 2 plastic drain fittingsto the unit using the gaskets, washersand nuts as shown.
VO0012
From the inside, install 2 snap bushingson top of the unit. Do not punchthe 2 knock-out sections.
Make a water trap loop in the tube toprevent the unit from drawing unpleasantodors from the drain source. Make surethis loop is situated BELOW the “T” asshown. This will prevent water frombeing drawn back up into the unit incase of negative pressure. Run the tubeto the floor drain or to an alternativedrain pipe or pail. Be sure there is aslight slope for the run-off.
TIE-WRAP
1 2
4 VD0231A
± 1”
If using a pail to collect water, locatethe tube end approximately 1” fromthe top of the pail in order to preventwater from being drawn back upinto the unit.
5 6
Inside view
Inside view
VO0005A
± 12" (± 305 mm)
± 12" (± 305 mm)
Cut 2 sections of plastic tubing,about 12” (305 mm) long and attachthem to each drain fitting. Join the 2short sections to the “T” junctionand main tube as shown.
3
WARNINGMake sure the intake hood is at least 6 feet (1.8 m)away from any of the following:• Dryer exhaust, high efficiency furnace vent,
central vacuum vent• Gas meter exhaust, gas barbecue-grill• Any exhaust from a combustion source• Garbage bin and any other source of contamination
!
17
ALTITUDE model
8.1 MAIN CONTROLS
8. Control Devices
VC0101
SMARTSETMODEPREF
VENTA model
VC0010
VENTA
20/40/60-MINUTE PUSH-BUTTON TIMER:
This remote illuminated switch is typically installed in bathrooms, kitchen and laundry room to provide 20, 40 or 60 minutesof high speed ventilation at the push of a button. 60-MINUTE CRANK TIMER:
This timer allows up to 60 minutes of high speed operation to be selected from a remote location.DEHUMIDISTAT:
This optional control helps control maximum humidity level during fall, winter and spring. You will find a relative humidity % scale meant to reduce the window condensation problems.
8.2 OPTIONAL CONTROLS
MODELS ALTITUDE DECO-TOUCH VENTA
MO
DE
S
Off Position X X X
Intermittent exchange OR OFF (ON - OFF or ON - Recirculation) X X
Low speed continuous exchange X X X
High speed continuous exchange X X X
Recirculation (manual mode performing air recirculation inside the house) X X
Program (programs the desired ventilation according to the period of the day) X
SMART (entirely automatic mode optimizing ventilation) X
DE
TE
CTO
R
TY
PE
S
Indoor Temperature X
Outdoor Temperature X
Indoor Relative Humidity X
IND
ICA
TOR
S
Mode indicator X X
Unit status X
Speed indicator X X
Maintenance indicator X X
Day and Hour indicators X
SWITCHESSliding button X
Push-button X X
DECO-TOUCH model
VC0117
18
8. Control Devices (cont’d)
8.3 OTHER FEATURES
FURNACE INTERLOCK (FOR FORCED AIR HEATING SYSTEM)The furnace can be interlocked so that it will run simultaneously with the ERV or HRV to ensure proper distribution offresh air throughout the house.
PERMANENT MEMORY
Our Altitude and Deco-Touch controls have a default memory feature in the event of a power outage. Even the date ofthe last service reminder is maintained as a convenience to the homeowner.NOTE: If the power failure duration is more than 4 hours, the day and hour settings must be reprogrammed (on
Altitude control only).
CONTROL UPGRADES
All controls can be used on any unit, so a Venta control can be upgraded to a Deco-touch or Altitude in the future.
9.1 DIMENSIONS AND SPECIFICATIONS (MAIN CONTROLS)
9. Installation of the Controls
VC0105A
1"(26 mm)
4¼" (107 mm)4" (102 m
m)
ALTITUDE
VOLTAGE: 12 volts DCDECO-TOUCH
VOLTAGE: 12 volts DC
FRONT VIEW SIDE VIEW
5" (127 mm)
VC0016A
5" (127 mm
)
1³/8"(35 mm)
FRONT VIEW SIDE VIEW
VENTA
VOLTAGE: 12 volts DC
VC0118A
2¾" (70 mm)
4½" (114 m
m)
19
9. Installation of the Controls (cont’d)
9.2 INSTALLATION OF THE MAIN CONTROL
WARNINGAlways disconnect the unit before making any connections. Failure in disconnecting power couldresult in electric shock or damage of the wall control or electronic module inside the unit.
CAUTION
!
4. Splice back the end of thecable to access the 4wires. Strip the end ofeach wire. Connect eachwire to its correspondingterminal on the back of thefront module: YELLOWwire to “Y”, RED wire to“R”, GREEN wire to “G”and BLACK wire to “B”.
5. Reinstall the front module over the back plate.
1. Route the cable from the unit to a convenient locationfor the wall control.
2. Detach the front modulefrom the mounting plateby pulling the bottom part.
3. Run the cable (4 wires)through the central openingof the mounting plate andmount this plate to thewall using screws (notincluded). If needed, usewall anchors (not included).
VC0102
VC0103
VE0173
BLACKWIRE
YELLOWWIRE
GREENWIRE
REDWIRE
CAUTIONBe careful not to pinch wires when reinstallingthe front module on its back plate.
9.2.1 Altitude Main Control Installation
Failure to comply with the following can cause erratic operation of the unit:• Never install more than one main wall control per unit.• Keep control low voltage wiring at least 1 foot (305 mm) away from motors, lighting ballast,
light dimming circuit and power distribution panel. Do not route control wiring alongside housepower wiring.
• Ensure the wires are securely connected.
9.2.2 Deco-Touch Main Control Installation
1. Cut a 2 7/8” x 1 ³/8” hole inwall at a convenient location for the wall control.Route the cable from theunit to this hole.
NOTE: Dimensions shownare for an installation without wall box.
2. Temporarily place theswitch over the hole andmark both mountingscrew hole positions.
3. Remove the switch, drillboth screw holes (Ø 3/16”)in wall and insert wallanchors (included).
VC0116A
Ø 3/16”, typ.
4. Strip the end of the cableto access the 4 wires. Stripthe end of each wire. Usinga small flat blade screwdriv-er, connect each wire to itscorresponding terminal onthe back of the wall control: YELLOW wire to“Y”, RED wire to “R”,GREEN wire to “G” andBLACK wire to “B”.
Y
B
GR
VE0243
5. Mount the wall control tothe wall.
VC0115
20
9.2.3 Venta Main Control Installation
1. Route the cable from the unit to the location of the control. The Venta wall control must be installed in a central location on the main floor. Typical locations for this control are kitchen, main hallways and family room.
2. Remove the buttons and the cover plate of the control.
3. Install the wall control 60 inches (1.5 m) from the floor and leave afree space of at least 2 inches (5 cm) to the right of the control toallow user to slide out the control instructions.
Use the template provided in the control box to position the wirehole and the screw holes. Use the screws and the plastic anchorsprovided in the installation kit to secure the control.
4. Connect the wires to the main control.
5. Make sure the instruction pull-out is in the occupant’s language. If not, turn it tothe other side.
6. Re-install the cover plate and the buttons.
VC0106
60" (1.5 m)
2"(5 cm)
Y R GB
VE
0124
VC0061
9.2 INSTALLATION OF THE MAIN CONTROL (CONT’D)
9. Installation of the Controls (cont’d)
21
9. Installation of the Controls (cont’d)
9.2.4 Main Control Electrical Connection
9.2 INSTALLATION OF THE MAIN CONTROL (CONT’D)
1. Connect the wires to their corresponding position inside the electrical compartment. Make sure the connections of the unit and of the wall controlcorrespond exactly.
2. Connect the optional controls (if applicable) by referring to section 9.3.
3. Do the appropriate connection to the furnace (if applicable) by referring to Section 9.4.
4. NOTE:If you are in a cold region (zone A or B, as defined in Section 4), set up “extended defrost” by removing jumper JU1F on the main circuit board inside the electrical compartment (see Section 10).
5. Plug in the unit and do the “overall verification” of the system as described in Section 12.
F F I OCOL Y R G BVE0084
987654321
OLOC
I
1 4 7
2 5 8
3 6 9
J3
MAIN PC BOARD
PUSH-BUTTON SWITCHES
J10L 0C I
VE0176A
REAR VIEWDEHUMIDISTAT orCRANK TIMER
9.3 OPTIONAL CONTROLS ELECTRICAL CONNECTION
22
W R G Y
W
R
G
C
Y
987654321
UNIT CONTROL CONNECTOR
THERMOSTATTERMINALS
FOUR WIRES
I OC OL Y R G BF F
J3TWO WIRESheating only
FURNACE24-VOLT
TERMINAL BLOCKTWO WIRES COOLING SYSTEM
VE0010A
Standard furnace interlock wiring
9. Installation of the Controls (cont’d)
9.4 ELECTRICAL CONNECTION TO THE FURNACE
W R G Y
W
R
Y
R
G
Y
C
J11
2
4
5
6
8
93
*FURNACE INTERLOCKRELAY
NC NO
7
COM
7THERMOSTAT
TERMINAL
Unit Control Module
4 WIRES
2 WIRES(heating only) wiring
nuts
FURNACE24-VOLT
TERMINAL BLOCK 2 WIRESCOOLING SYSTEM
GRAY BROWNRED
GREEN
BLUE
9-PIN AMP PLUG
*FURNACE INTERLOCK RELAY, PART NO. 12658VE0009A
Alternate furnace interlock wiring
For a furnace connected to cooling system:
On some older thermostats, energizing the “R” and “G” terminals at the furnace has the effect of energizing “Y” at thethermostat and thereby turning on the cooling system. If you identify this type of thermostat, you must use the “alternate furnace interlock wiring”. An additional control relay will then have to be installed.
WARNINGNever connect a 120-volt AC circuit to the terminals of the furnace interlock (standard wiring).Only use the low voltage class 2 circuit of the furnace blower control.
!
9.5 FURNACE INTERLOCK TYPES
The new TII (Timed Intermittent Interlock) function consists in 2 modes: the standard mode and the special mode.Therefore, the electronic board terminal of the Solo and Duo units has now 2 additional jumpers intalled across C andD terminals.
STANDARD MODE
The standard mode is the default mode (the interlock function stay as it was). On standard mode, the jumper positionson terminal C and D keep them non-active:
SOLO UNITS DUO UNITS
SPECIAL MODE
The special mode drives the furnace interlock relay independently than the HRV/ERV operation. The K4 relay is activated for 10 minutes, and then is deactivated for a 20-minute period, no matter the HRV/ERV command, even ifthe HRV/ERV is stopped. To perform the special mode, unplug the unit and change the jumper locations as shownbelow:
SOLO UNITS DUO UNITS
NOTE: For both Solo and Duo units, C and D terminals are now activated.
A B C D E F G A B C D E F GVE0125
A B C D E F G A B C D E F GVE0126
A1
M1
M2
K1
RE
LAY
K2
RE
LAY K
5R
ELA
Y
FAN
MO
TOR
DA
MP
ER
MO
TOR
NE
UT
RA
L
ME
DN
CH
IGH
LOW
J1
6J1
3
J1
4
J1
9
K4
RE
LAY
J3
1
J3
2
FU
RN
AC
E B
LOW
ER
INT
ER
LOC
KC
LAS
S 2
CIR
CU
IT O
NLY
ELE
CT
RO
NIC
AS
SE
MB
LY
S1
120V
60H
z
FR
OM
MA
INJ1
2
J1
1
J1
8
VE
0018
A
23
10. Wiring Diagrams
BK
G R Y R BK
Y
NO
TE
4
WA
LL C
ON
TR
OL
WA
LL C
ON
TR
OL
WA
LL C
ON
TR
OL
WA
LL C
ON
TR
OL
OV
ER
RID
E S
WIT
CH
OV
ER
RID
E S
WIT
CH
OV
ER
RID
E L
ED
FU
RN
AC
E B
LOW
ER
INT
ER
LOC
K
NO
TE
S 1
, 5
NO
TE
5O
PT
ION
AL
NO
TE
S 5
, 6O
PT
ION
AL
M1
X2
M2
1
21
123
1 2
4
76
9
3
456789
2 3
1 2 3
NE
UT
RA
L
LOW
HIG
H
ME
DIU
M
FAN
MO
TOR
X1
GY
O G R BL
GY
O GN
CR
(NO
TE
2)
BN
BN
C1
BL
BL
GD
AM
PE
R M
OTO
R
MA
IN E
AR
TH
ING
PO
INT
R
O
GY
W
G
T1
R1
A1
DE
FR
OS
TT
EM
PE
RAT
UR
ES
EN
SO
R
JU1J4 J1
J3ABCDEFG
FFIOCOLYRGB
ELE
CT
RO
NIC
AS
SE
MB
LY
BL
BL
G
BLB
L
CO
M
W1
G
BK
W BK
DO
OR
INT
ER
LOC
KS
WIT
CH
S1N
O
NE
UT
RA
L
LIN
EB
K
VE
0017
A
F1
NO
TE
7
120V
NE
MA
-15P
5-15
PLU
G
Mod
els:
SO
LO 1
.5 a
nd 2
.0
NOTE
S1-
Con
trols
ava
ilabl
e. S
ee S
ectio
n 8.
0 (L
ow v
olta
ge o
nly,
12VD
C)
2-Th
e fa
ctor
y se
t wiri
ng fo
r blo
wer
spe
ed s
elec
tion
is h
igh
and
low.
Med
ium
spe
edca
n be
sel
ecte
d in
stea
d of
low
spe
ed. D
isco
nnec
t the
RED
wire
from
the
mot
orR
ED ta
p an
d co
nnec
t it t
o th
e m
otor
BLU
E ta
p.
3-If
any
of th
e or
igin
al w
ire, a
s su
pplie
d, m
ust b
e re
plac
ed, u
se th
e sa
me
oreq
uiva
lent
wire
.
4-U
se th
e fa
ctor
y su
pplie
d pr
otec
tive
tubi
ng.
5-Th
e fie
ld w
iring
mus
t com
ply
with
app
licab
le c
odes
, ord
inan
ces
and
regu
latio
ns.
6-Th
e fu
rnac
e fa
n ci
rcui
t mus
t be
clas
s 2
circ
uit o
nly.
7-SP
ECIF
IED
UL L
ISTE
D/CS
A CE
RTIF
IED
LINE
FUS
E.Li
ttelF
use
(225
003
), 2A
G F
ast-A
ctin
g Fu
se. 2
24/2
25 S
erie
s, R
atin
g: 3
A.
LINE
VO
LTAG
E
LOW
VO
LTAG
E AN
DFI
ELD
WIR
E
COLO
R CO
DEBK
BLAC
KNC
NO C
ONN
ECTI
ON
BLBL
UEO
ORA
NGE
BNBR
OW
NR
RED
GG
REEN
WW
HITE
GYG
REY
YYE
LLO
W
FUN
CTI
ON
TAB
LER
ELAY
MO
DE
K1K2
K4*
K5
Inte
rmitt
ent
00
01
Exch
ange
Low
10
10
Exch
ange
Hig
h1
11
0
Circ
ulat
ion
Low
10
11
Circ
ulat
ion
Hig
h1
11
1
Def
rost
Cyc
le1
11
1
Off
00
01
0 =
Rel
ay c
oil i
s de
-ene
rgiz
ed
1 =
Rel
ay c
oil i
s en
ergi
zed
* On
spec
ial m
ode,
K4
is c
yclin
g 10
min
. ON
and
20 m
in. O
FF
Con
nect
ion
Logic
WARNINGRisk of electric shocks. Before performing any maintenance or servicing, always disconnect theunit from its power source. This product employs overload protection (fuse). A blown fuse indicatesan overload or short-circuit situation. If the fuse blows, unplug the product from the outlet.Replace the fuse as per the servicing instructions (follow product marking for proper fuse rating)and check the product. If the replacement fuse blows, a short-circuit may be present and the productshould be discarded or returned to an authorized service facility for examination and/or repair.
!
DEF
RO
ST T
IME
JUM
PER
S TA
BLE
MO
D
EFR
OST
/VEN
TILA
TIO
NTY
PE
MIN
UTE
S
23°F
5°F
-22°
FJU
1AJU
1BJU
1CJU
1DJU
1EJU
1FJU
1G-5
°C-1
5°C
-27°
C
INO
UT
OU
TO
UT
ININ
OU
TST
AND
ARD
MO
DE
6/60
6/32
6/20
4372
0, 4
5720
,437
25, 4
5725
INO
UT
OU
TO
UT
INO
UT
OU
TEX
TEN
DED
DEF
RO
ST10
/30
10/2
010
/15
STAN
DAR
D M
OD
E
OU
TIN
ININ
ININ
OU
TSP
ECIA
L M
OD
E6/
606/
326/
2043
720,
457
20,4
3725
, 457
25
OU
TIN
ININ
INO
UT
OU
TEX
TEN
DED
DEF
RO
ST10
/30
10/2
010
/15
SPEC
IAL
MO
DE
A B
C D
E F
G
2 1
JU 1
. .
. .
. .
. .
. .
. .
. .
24
10. Wiring Diagrams (cont’d)
Mod
els:
DU
O 1
.2, 1
.4 a
nd 1
.9B
KG R Y R B
KY
NO
TE
4
WA
LL C
ON
TR
OL
WA
LL C
ON
TR
OL
WA
LL C
ON
TR
OL
WA
LL C
ON
TR
OL
OV
ER
RID
E S
WIT
CH
OV
ER
RID
E S
WIT
CH
OV
ER
RID
E L
ED
FU
RN
AC
E B
LOW
ER
INT
ER
LOC
K
NO
TE
5
NO
TE
5O
PT
ION
AL
NO
TE
6O
PT
ION
AL
TH
ER
MA
L W
HE
EL
AS
SE
MB
LY
GR
OU
ND
NE
UT
RA
L
LIN
E
CA
PAC
ITO
R
DR
IVIN
G M
OTO
RR
T1M
3
BY
PAS
S T
HE
RM
AL
AC
TU
ATO
R
R2
C2
X3
M1
X2
M2
G W R BK
V V
1 2 3 4
1
21
123
11 2
4
7
6
9
323
456789
2 3
1 2 3
Y VB
N
NE
UT
RA
L
ME
DIU
M
HIG
H
LOW
FAN
MO
TOR
X1
GY
O G R BL
GY
O GN
CR
BN
BN
C1
Y Y GD
AM
PE
R M
OTO
R
R
V
O
YB
N
BN
GY
BL
BK
T1
R1
A1
DE
FR
OS
TT
EM
PE
RAT
UR
ES
EN
SO
R
JU1J4 J1
J2
J3
ABCDEFG
FFIOC
OLYRGB
ELE
CT
RO
NIC
AS
SE
MB
LY
MA
IN E
AR
TH
ING
PO
INT
G
BL
BL
GB
KW
CO
M12
0V 6
0 H
z
W1
W
NE
MA
-15P
5-15
PLU
G
BK
DO
OR
INT
ER
LOC
KS
WIT
CH
S1
NO
NE
UT
RA
L
LIN
EB
K
VE
0019
A
GR
OU
ND
NE
UT
RA
L
LIN
E
CA
PAC
ITO
R
DR
IVIN
G M
OTO
RR
T1M
3
BY
PAS
S T
HE
RM
AL
AC
TU
ATO
R
R2
C2
X3
G W R BK
V V
1 2 3 4
GR
OU
ND
NE
UT
RA
L
LIN
E
CA
PAC
ITO
R
DR
IVIN
G M
OTO
RR
T1M
3
BY
PAS
S T
HE
RM
AL
AC
TU
ATO
R
R2/
R3
C2
X3
G W R BK
V V
1 2 3 4
BODINE OR EASTERN AIR DEVICES
SEE
BOXE
S BE
LOW
WARNER ELECTRIC
F1
NO
TE
7
G
A1
M1
RT
1
M3
M2
K1
RE
LAY
K2
RE
LAY
K5
RE
LAY
K3
RE
LAY
K4
RE
LAY
FAN
MO
TOR
BY
PAS
S
TH
ER
MA
L A
CT
UAT
OR
NE
UT
RA
L
LOW
NC
HIG
H
ME
DIU
M
J1
2
J1
1
J1
8
J1
5
J1
6J1
3
J1
4
J9
1
J1
7
J2
2
J3
1
J3
2FU
RN
AC
E B
LOW
ER
INT
ER
LOC
KC
LAS
S 2
CIR
CU
IT O
NLY
ELE
CT
RO
NIC
AS
SE
MB
LY
J2
3
FR
OM
MA
IN
S1
120V
60H
z
VE
0020
A
J2
1D
RIV
ING
MO
TOR
DA
MP
ER
MO
TOR
JUM
PER
S TA
BLE
MO
DEL
JU1A
JU1B
JU1C
JU1D
JU1E
JU1F
JU1G
ININ
OU
TO
UT
ININ
OU
TST
AND
ARD
MO
DE
4370
0, 4
5700
, 437
10
ININ
OU
TO
UT
INO
UT
OU
TST
AND
ARD
MO
DE
EXTE
ND
ED D
EFR
OST
ININ
ININ
ININ
OU
TSP
ECIA
L M
OD
E 43
700,
457
00, 4
3710
ININ
ININ
INO
UT
OU
TSP
ECIA
L M
OD
E EX
TEN
DED
DEF
RO
ST
FUN
CTI
ON
TAB
LER
ELAY
DEF
RO
ST
MO
DE
K1 &
K4*
K2K3
K5
Inte
rmitt
ent
00
00
Con
tinuo
us L
ow1
01
0
Con
tinuo
us H
igh
11
10
K5 a
ctiv
e on
ly (-
15°C
<T<+
10°C
)
Circ
ulat
ion
Low
10
00
Circ
ulat
ion
Hig
h1
10
0
Def
rost
Cyc
le1
10
0
Off
00
01
0 =
Rel
ay c
oil i
s de
-ene
rgiz
ed
1 =
Rel
ay c
oil i
s en
ergi
zed
* On
spec
ial m
ode,
K4
is c
yclin
g 10
min
. ON
and
20 m
in. O
FF
NOTE
S
1-C
ontro
ls a
vaila
ble.
See
Sec
tion
8.0.
(Low
vol
tage
onl
y 12
VDC
)
2-Fa
ctor
y se
t w
iring
for
blo
wer
spe
ed s
elec
tion
is h
igh
and
med
ium
. Lo
w s
peed
can
be
sele
cted
ins
tead
of
med
ium
spe
ed.
Dis
conn
ect t
he R
EDw
ire fr
om th
e m
otor
BLU
E ta
p an
d co
nnec
t it t
o th
e m
otor
RED
tap.
3-If
any
of th
e or
igin
al w
ire, a
s su
pplie
d, m
ust b
e re
plac
ed, u
se th
e sa
me
or e
quiv
alen
t wire
.
4-U
se fa
ctor
y su
pplie
d pr
otec
tive
tubi
ng.
5-Fi
eld
wiri
ng m
ust c
ompl
y w
ith a
pplic
able
cod
es, o
rdin
ance
s an
d re
gula
tions
.
6-Fu
rnac
e fa
n ci
rcui
t mus
t be
clas
s 2
circ
uit o
nly.
7-SP
ECIF
IED
UL L
ISTE
D CE
RTIF
IED
LINE
FUS
E..L
ittel
Fuse
(225
003
), 2A
G F
ast-A
ctin
g Fu
se, 2
24/2
25 S
erie
s, R
atin
g: 3
A.
DRIV
ING
MO
TOR
DRIV
ING
MO
TOR
DRIV
ING
MO
TOR
CAPA
CITO
RRE
SIST
OR
1.7
uF, 2
50 V
AC30
0 O
hms,
7W
Bod
ine
1 uF
, 330
VAC
400
Ohm
s, 1
0WE
aste
rn A
ir D
evic
es
1 uF
, 250
VAC
800
Ohm
s, 8
WW
arne
r Ele
ctric
STAN
DAR
DEX
TEN
DED
-5°C
9/60
min
10/3
0 m
in-1
5°C
9/32
min
10/2
0 m
in-2
7°C
9/20
min
10/1
5 m
in
LINE
VO
LTAG
E
LOW
VO
LTAG
E AN
DFI
ELD
WIR
E
COLO
R CO
DEBK
BLAC
KNC
NO C
ONN
ECTI
ON
BLBL
UEO
ORA
NGE
BNBR
OW
NR
RED
GG
REEN
-YEL
LOW
VVI
OLE
TGY
GRE
YW
WHI
TEY
YELL
OW
WARNING!
A B
C D
E F
G
2 1
JU 1
. .
. .
. .
. .
. .
. .
. .
Risk of electric shocks. Before performing any maintenance or servicing, always disconnect theunit from its power source. This product employs overload protection (fuse). A blown fuse indicatesan overload or short-circuit situation. If the fuse blows, unplug the product from the outlet.Replace the fuse as per the servicing instructions (follow product marking for proper fuse rating)and check the product. If the replacement fuse blows, a short-circuit may be present and the productshould be discarded or returned to an authorized service facility for examination and/or repair.
Con
nect
ion
Logic
25
WHAT YOU NEED TO BALANCE THE UNIT• A magnehelic gauge capable of measuring 0 to 0.5 inch of water
(0 to 125 Pa) and 2 plastic tubes.• The balancing chart provided with the unit.
PRELIMINARY STAGES TO BALANCE THE UNIT• Seal all the unit ductwork with tape. Close all windows and doors. • Turn off all exhaust devices such as range hood, dryer and bathroom
fans. • Make sure the balancing dampers are fully open. • Make sure all filters are clean (if it is not the first time you balance the
unit).
BALANCING PROCEDURE1. Set the unit to high speed:
Make sure that the furnace blower is ON if the installation is in any wayconnected to the ductwork of the cold air return. If not, leave furnace blowerOFF. If the outside temperature is below 0°C / 32°F, make sure the unit isnot running in defrost while balancing. (By waiting 10 minutes after plugging the unit in, you are assured that the unit is not in a defrost cycle.)Disconnect the wire of the bypass damper (Duo only).
2. Place the magnehelic gauge on a level surface and adjust it to zero.
3. Connect tubing from gauge to EXHAUST air flow pressure taps (see diagram).Be sure to connect the tubes to their appropriate high/low fittings. If thegauge drops below zero, reverse the tubing connections. NOTE: It is suggested to start with the exhaust air flow reading
because the exhaust has typically more restriction than the fresh air, especially in cases of fully ducted installations or source point ventilation. Place the magnehelic gauge upright and level. Record equivalent AIR FLOW of the reading according to the balancing chart.
4. Move tubing to FRESH air flow pressure taps (see diagram). Adjust thefresh air balancing damper until the fresh air flow is approximately thesame as the EXHAUST air flow. If fresh air flow is less than exhaust airflow, then go back and adjust the exhaust balancing damper to equal thefresh air flow.
5. Secure both dampers in place with tape or with a fastening screw.
6. Write the required air flow information on a label and stick it near the unitfor future reference (date, maximum speed air flows, your name, phonenumber and business address). Connect the wire of the bypassdamper (Duo only).
NOTE: The unit is considered balanced even if there is a difference of ± 10 cfm or ± 5 l/s or 17 m³/h between the two air flows.
11. Air Flow Balancing
VP0009
VP0010
VD0052
VE0021
VD0051
VP0011
SOLO Fresh air flow
Exhaust air flow
Exhaust air flow
Fresh air flow
NOTE: Always unplug bypass wire while balancing a Duo.
DUO
26
VENTA (6 different control scenarios to be tested)
12.1 MAIN CONTROLS
This procedure allows the installer to verify that all modes of operation are fully functional. During the verification of a main control, make sure that all optional remote controls are inactive.
12. Overall Verification
Set the slider Set dehumidistat Results expectedswitch to dial to fan speed / damper
1 OFF maximum counterclockwise motor off / closed2 OFF maximum clockwise motor off / closed3 MIN. maximum counterclockwise low speed / open4 MIN. maximum clockwise high speed / open5 MAX. maximum counterclockwise high speed / open6 MAX. maximum clockwise high speed / open
VC0010
VENTA
At its very start-up, theAltitude wall control willperform a bootingsequence before beingready to operate. The boot-ing sequence is donewhen the hour display isflashing.
Refer to the installationsheet included with theAltitude wall control for more details in programming andsetting preferences.
VC0101
SMARTSETMODEPREF
ALTITUDE DECO-TOUCH
DEHUMIDISTAT:Turn dial to the maximum clockwise position (20%).
Result expected:
Motor speed changes to high.
60-MINUTE CRANK TIMER:Activate the timer.
Results expected:Motor speed: High for up to 60 minutes.
12.2 OPTIONAL CONTROLS
First, turn OFF the main control device before checking the remote optional controls.
20/40/60-MINUTE PUSH-BUTTON TIMER:Activate the push-button. Within 2 seconds, push one time for 20 minutes, two times for 40 minutes or three times for a 60-minute activation.
Results expected:1. Motor speed: High for 20, 40
or 60 minutes.2. Indicator light goes “ON” and
flashes every 5 seconds (onetime to indicate a 20-minute operation, two timesfor a 40-minute, and three times for a 60-minute operation).
NOTE: To stop activation, push one more time.
VC0007
20 min.
40 min.
60 min.
OFF
10
TurnPast
VC0017
20
3040
50
60
MINUTES
HOLD
VC0009
Refer to the installation sheetincluded with the Deco-Touch wallcontrol.
VC0117
• Review with the user the steps required for the regular maintenance of her/his ventilation system. These steps aredescribed in detail in the user manual:
• Warn the user of the necessity to rebalance the system following a major house renovation or following the installation of any extra registers.
• Make sure the user understands how to use the main control as described in the user manual.
13. Maintenance / Instructions for User
FOUR TIMES A YEAR:• Inspect the intake hood, and clean if needed.• Clean the filters.• Clean the interior of the cabinet and clean the door.• Clean the condensation tray and inspect the drain tubing (SOLO only).
ONCE A YEAR:• Clean the recovery module (core or thermal wheel).• Clean the blades of the blower wheels if needed.
WARNINGRisk of electric shocks. Before performing any maintenance or servicing, always disconnect theunit from its power source.
!
CAUTIONDo not oil the motor. It is already permanently lubricated.
14. Troubleshooting
27
Problems Possible causes You should try this
1. The error code E1 is displayed on Altitude orDeco-Touch wall controlscreen.
• The wires may be inreverse position.
• The wires may be broken.• The wires may have a
bad connection.
• Ensure that the color coded wires have been connected totheir appropriate places.
• Inspect every wire and replace any that are damaged.• Ensure the wires are correctly connected.
2. There is no outside temperature displayedon Altitude wall controlscreen .
• The unit thermistor is defective.
NOTE: At its very start-up or after a power failure, it takessome minutes before the outside temperatureappears on screen. The delay duration dependson which operation mode the wall control is set.The shortest delay is obtained when the wall control is set on MIN or MAX in VENT Mode.
• Replace the unit thermistor.
3. Altitude or Deco-Touchwall control screen alternates between normal display and E3.
• The Altitude or Deco-Touch wall controlis defective.
• Replace the Altitude or Deco-Touch wall control.
4. On Altitude wall control,there is an important difference between temperature displayedand real temperature.
• The unit thermistor isdefective.
• The unit damper hasbeen blocked or broken.
• Replace the unit thermistor.
• Check for the proper operation of the unit damper;replace if necessary.
5. The damper actuatordoes not work.
• The 9-pin connectormay have a loose connection.
• The damper actuatormay be defective.
• The circuit board maybe defective.
• Unplug the unit and check to make sure all the crimp connections are secured. Check the damper actuatorconnections as well.
• Feed 120 V directly to the damper actuator. If the problempersists, replace the damper actuator.
• Replace the circuit board if the problem is not solvedby the above.
NOTE: Be sure to unplug and inspect the unit before proceeding with these steps.
If the unit does not work properly, reset the unit by unplugging it for one minute and then replug it. If it stillnot working properly, refer to table below.
13. Troubleshooting (cont’d)
Problems Possible causes You should try this
6. Unit doesn't work. • The circuit board maybe defective.
• The power cord fusemay be blown.
• Unplug the unit. Disconnect the main controland the optional control(s) (if need be).Jump B and G (BLACK and GREEN) terminals. Plug the unit. If the motor runson high speed and the damper opens,the circuit board is not defective.
• Unplug the unit. Unscrew the fuse holder(grey circle on illustration beside).Check if the fuse is blown (the strand isbroken). If it is blown, replace the fuseaccording to the specifications on theunit power cord tag.
7. The wall control doesnot work.
• The wires may be inreverse position.
• The wires may be broken.• There may be a short-circuit.• The wire in the wall
OR the wall controlmay be defective.
• The circuit board maybe defective.
• Ensure that the color coded wires have been connectedto their appropriate places.
• Inspect every wire and replace any that are damaged.• With the help of a multimeter, check for continuity.• Jump B and G (BLACK and GREEN) terminals. If unit
switches to high speed, remove the wall control and testit right beside the unit using another shorter wire. If thewall control works there, change the wire. If it doesn’t,change the wall control.
• If the unit does not switch to high speed, replace thecircuit board.
8. The Dehumidistat doesnot work OR the20/40/60-min. push-button timer doesnot work or is indicatorlight does not stay on.
• The dehumidistat ORpush-button may bedefective,
• Jump the OL and OC terminals. If unitswitches to high speed, remove theDehumidistat or push-button and test itright beside the unit using anothershorter wire. If it works there, changethe wire. If it doesn’t, change theDehumidistat or push-button.
9. The defrost cyclet doesnot work (the fresh airduct is frozen OR thefresh air distributed isvery cold).
• Ice deposit may be hindering the damperoperation.
• The damper rod or theport damper itself maybe broken.
• The damper actuatormay be defective.
• The circuit board maybe defective.
• The thermistor may bedefective.
• Remove the ice.
• Inspect these parts and replace if necessary.
• Plug in the unit and select “MIN” or “MAX”. Press the doorswitch and see if the port damper opens. If it doesn’topen, feed 120V directly to the damper actuator. If theport damper still doesn’t open, replace the damper actuator.
• Unplug the unit. Unplug the defrost sensor wire (see J4on electrical diagram Section 9). Plug the unit back in. Select “MIN” and make sure the unit is adjusted for lowspeed operation (turn all Humidity Controls maximum counterclockwise).Wait 3 minutes. The unit should switch to high speed and the damper at the fresh air intake port should close (defrost mode). If this doesn’t happen,then replace the circuit board.
• If the defrost mode works well after having disconnectedthe thermistor wire (above test), this means the thermistoris probably defective. You should replace it.
VE0082
BG
VE0194
VE0067
OLOC