Instruction for use
Ventilation Control VCM 1004
ApplicationThe ventilation control module VCM 1004 is suitable for daily ventilation and cansimultaneously trigger up to 4 groups. The ventilation control is universally applicable dueto its latest state of the art and very small dimensions. Window drives, louver drives orelectric jalousies can be alternatively connected on every individual group. Special functionsper group output can be allocated via a programming mode. The ventilation control modulecan be directly integrated in the house distributing box, or surface/ or flush mounted usinghousings, optional available.Different detectors can be allocated to every group (wind/ or rain detectors, thermostatswitches, timer, actuator of the Building Management System). Programming is effecteddirect on the control. The groups are operable via remote controls, wall control panels orvent buttons as well as direct on the VCM 1004. Two of the Variostat groups can be additionallyconnected with dependence on the ventilation groups.
mains supply230VAC / 50Hz
drivegroups1-4
control panel groups 1-4
control panel quadruple withintegrated IR receiver
rain detector/room temperature
control
windowcontact
IRreceiver
or
Variostatgroup1-2
centralbutton
IRremote control
2
Auto
1
2
3
4
1
2
1
GroupPower
VCM1004
1
2
3
4
Ventilatio
n Control Module
SET
In:230VAC / 50Hz
Out:24VDC / 4A
1
2
P
LP
LP
LP
L
1
2
3
4
a
a
a
a
b
b
b
b
12
34
2/16 VCM 1004 Rev.:1.2
Remove after installa
tion / befo
reswitc
hing on!
Nach der Installatio
n / vor Inbetriebnahme entfe
rnen!
GuaranteeYou will get 2 years guarantee for all D+Hproducts from date of verified handing overof the system up to maximal 3 years afterdate of delivery, when mounting and startinghas been carried out by a D+H authorizeddistributor.
D+H guarantee is expired, with connectionof D+H components with external systemsor with mixing of D+H products with parts ofother manufacturers.
Please observe!This instruction includes descriptions andconnecting plans of components, which arenot contained in extent of supply of thecontrol panel. You can get these parts andmany other ones separate at your D+Hdistributor. Further connecting plans areavailable there as well.
VDE 0100 for electric systems andregulations of EVU for electric mains have tobe observed.
Do notremove label on
ventilation slots beforemounting of the VCM 1004.
Technical DataRated voltage : 230VAC / 50HzPower consumption : 120VAInterfering emission : DIN EN 55022
DIN EN 50081-1,DIN EN 61000-3-2,DIN EN 61000-3-3,DIN EN 61000-6-2
Resistanceto jamming : DIN EN 61000-4-2
to -6,DIN EN 50130-4
Protective category : IIProtective system : IP30Class of rating : Short-timeOutput voltage : 24VDC/ Residual
ripple < 5%safe output current : 4A / ED20working temperature : 0-50°C /
max. 70% rel. HDimensions (wxhxd) : 160 x 90 x 65
for top hat railmounting
Outputs are short circuit proof; with thatconventional fuses are dropped.
ContentPlease observe!/ Software state .............. 2Technical Data / Guarantee ...................... 2Front view/ Pictograph .............................. 3Accessories ........................................... 3-4Wiring plan,
line lenghts, cross sections .................. 5Connecting plans ................................... 6-7Adjusting of address control panels ........ 8Configuration ............................................. 9Programming functions:
group allocationcentral inputs ........................................ 10group allocationvent button inputs .................................. 11
Example for application:with one VCM 1004 .............................. 12with two VCM 1004 ............................... 13
Open/ Close/ Stop via:the front panel ....................................... 14control panels ....................................... 15
Control „10 minutes ventilation“ ............. 16Control Variostat ..................................... 16
Software revisionThese instruction are valid as of softwarerevision C64101A04!
Ventilation ControlModuleVCM 1004
Software stateC64101A04
3/16VCM 1004 Rev.:1.2
2
Auto
1
2
3
4
1
2
1Group
Power
VCM 10041
2
3
4
Ventilation Control Module
In: 230VAC / 50HzOut: 24VDC / 4A
SET
1 2P L P L P L P L
1 2 3 4a a a ab b b b
1 2 3 4
1 2 1 2°C
1 2on on°C
°C
+5,
7V
SC
L
IRSD
A
Power supply
230VAC / 50Hz / 120VALN
Front View
Accessories Drives
VCD 22 onpivot-hung windowopening inward
Mounting of the drive:You will find the mounting instructions in theinstruction for use of the drive.
VCD 22 on aroof window
Auto
SET
Auto
Central inputs
Louver / Jalousie
Window
Group levels/
Programming mode
Automatic safety function
in direction Open
Automatic safety function
in direction Closed
Control panel
Electro motor drive
Voltage
Variostat
Pictograph Explanation
4/16 VCM 1004 Rev.:1.2
ST OP
LÜFTUNG
15
20
25
30
°C
105
((
Room temperature controlRTR 83Room temperature controlfor controlling of ventilationvia room-temperature.
Switching rangeadjustable from 5 - 30°C.
Rain detector VRS 10Rain detector forautomatic closingof windows in caseof rain.
Variostat VST 20The heat valve will beautomatically closedduring every ventilationprocess throughelectronic triggeringvia window contacts,window drives, wall/ orIR-remote controls.Consequently, energy costs will be saved.
IR-receiver IE 10-3BExternal receiver forIR-remote control.Mounting on 55mmflush box or insuspended ceiling.
Accessories
Vent Buttons and Control Panels
LT 43 UVent buttons for controlling of individual drive groups.Several vent buttons can be connected in parallel per group.Mounting in 55 mm flush box (not included).Surface frame available as accessories.
LF 10-4BControl panel (mountingon 55mm flush box) forwindow drives, heatingradiators (Variostat) andshading systems withintegrated infraredreceiver
LF 10-2AControl panel (mountingon 55mm flush box) forwindow drives, heatingradiator (Variostat) andshading systems
IS 10-4Remote control forwindow drives, heatingradiators (Variostat)and shading systems
5/16VCM 1004 Rev.:1.2
0,35A 1 2 3 4 5 60,5A 1 2 3 41A 1 2
2 x 0,5mm² 120 60 40 30 24 202 x 0,75mm² 180 90 60 45 36 30
2 x 1mm² 240 120 80 60 48 402 x 1,5mm² 360 180 120 90 72 60
Antriebe /drives
ATTENTION!Install and feed weakcurrent lines separatelyfrom supply mains.
Wiring Plan (Paragon)
Line lengths and Cross sections:Earthed conductor must not be wired!
cross section (mm²) = simple cable length (m) x number of drives80***
***Applies only for drives with 1A drive current.Use drive current „160“ for drives with 0,5A and drive current „230“ for drives with 0,35A.
See also page 7 to this!
ventbutton
rain detectorroom temperaturecontrol
controlpanel
Drive
external controle.g. D+H vario
to further ones
M
IY (St) Y2x2x0,6
NYM-I 3x1,5
IY (St) Y2x2x0,6
IY (St) Y2x2x0,6
IY (St) Y2x2x0,6
see line length and cross sections
230VAC
24VDC
receiver
IY (St) Y2x2x0,6max. 50m
Control paneldouble
IY (St) Y4x2x0,6
IY (St) Y3x2x0,6max. 50m
Control panel quadruplewith IR-receiver
to further ones
6/16 VCM 1004 Rev.:1.2
Connection Vent Buttons, Detectors
-
-
-
-
LT3-closed
LT1-closed
LT4-closed
LT2-closed
LT3-open
LT1-open
LT4-open
LT2-open
LED3-open
LED1-open
LED4-open
LED2-open
LP
LP
Co
ntr
olp
an
elt
wo
fold
LF
10-2
A
rt
rt
rt
rt
closed
closed
closed
closed
–N
–N
–N
opensignal
opensignal
opensignal
opensignal
open
open
open
open
LL
LL
P-
P
Ventbutton
LT
43
U
Regen
–
–
+24V
21
34
56
R
-
-
+24V
Zz1
Zz2
Za1
Za2
closed
–N
open
23
1
closed
–N
open
23
1
Centr
alb
utto
n
optio
na
l
< >
12
L
1L
2L
3L
4
VC
M1004
<optio
nal>
Rain
dete
ctor
VR
S10
Le
ve
l1
Le
ve
l2
41
23
75
6
Room
-te
mpera
ture
-co
ntr
ol
RT
R83
7/16VCM 1004 Rev.:1.2
Mo
t.4
a
Mo
t.3
a
Mo
t.4
b
Mo
t.3
b
bl
br
brunchbox
bl
br
Mo
t.2
a
Mo
t.1
a
Mo
t.1
b
Mo
t.2
b
VCM 1004
a a a ab b b b
1 2 3 4
Connection Drives
1 2 1 2°C
1 2on on°C
°C
VCM 1004
heating
1:on
heating
2:on- -
heating
1:re
duction
Heating
reduction
2:
win
dow
conta
ct
2 --
Variosta
t1
win
dow
conta
ct1
Variosta
t2
factory-setDIP-switch
SC
L-
SD
A
+5,7
V IR
+5,
7V
SC
L
IRSD
A
- +5,7
V
IR
LF 10-4BControl panel quadruple
IE 10-3BIR-receiver
1 2 3 4 5
12 3
4
1 2 3 4 5 6 7
shield(connect only incentral control)
Connection Variostat, Window Contact, BUS, IR
Running direction ofdrives:Change poles of lines(„Mot.a“ and „Mot.b“)of drive supply ifrunning directionis wrong.
Maximum number ofdrives:per group max. 2A:6 drives with 0,35A each, or4 drives with 0,5A each, or2 drives with 1A each
all groups together max. 4A:11 drives with 0,35A each, or8 drives with 0,5A each, or4 drives with 1A each
8/16 VCM 1004 Rev.:1.2
1 2 3 4
OPEN
group 1
group 2
Variostat 1
group
group
3
4
Variostat 2
group
group
group
group
1
2
3
4
group
group
1
2
Variostat 1
Variostat 2
OFF
ON
OFF
ON
OFF
OFF
ON
ON
group 1
2
Variostat 1group
OFF
ON
CLOSE = ONOPEN = OFF
ON
12 DIL-switch
2-pole
IS 10-4Remote control
LF 10-4BControl panel quadruple
1 2
ON
LF 10-4B IS 10-4
DIL-switch4-pole
1 2 3 4
OPEN
Adjusting of Address Control Panels
9/16VCM 1004 Rev.:1.2
2
Auto
1
2
1
Safety function switched * /
Safety function switched *
off
on
through briefly pressing of the runningdirection button the window / the louverwill automatically open or close up to thestopp position
when opening the window / the louver,keep running direction button presseduntil the desired opening width isreached; when closing the window /the louver, keep running directionbutton pressed
Windows/ louvers do not close automatically,(in case of wind/ rain, temperature not either)
LED lightens
/LED is extinguished
Activation Central open/ closed /
Deactivation Central open/ closed /
LED lightens
LED is extinguished
Central open/ closed 1Central open/ closed 2
12
Activation Variostat/
Deactivation Variostat/
LED lightens
LED is extinguished
Variostat 1Variostat 2
12
Activation louver/ jalousie
Activation windows/
LED lightens
LED is extinguished
“10 minutes ventilation” notpossible!
* Auto / safety function:
If the safety function is activated (LED isextinguished), the remaining functions (10 minutesventilation, central open/closed) are not activated.
windows, which are within arm's reach, can only be opened orclosed when the vent button is kept pressed.
Several functions are programmable per group.”Central open / closed” has uppermost function priority.
Safetyfunction
Configuration
10/16 VCM 1004 Rev.:1.2
1 1 1 1 1 1
2 2 2 2 2 2
3 3 3 3 3 3
4 4 4 4 4 4
Group Group Group Group Group Group
Power Power Power PowerPower Power
SET SET SET SET SET SET
3 Sec. 1x 1x 1x 1x
*
*
*
*
* Configuration of group 1-4
= =ON OFF
Adjusting of Groups
Programming FunctionThe VCM 1004 has two central inputs for the function Open and Closed. Central input 1 and/or central input 2 can be allocated to every single group.You can optionally connect to central inputs 1+2 a rain detector, thermostat switch, centralbutton, timer, wind detector or an actuator of the Building Management System (e.g. EIB-BUS). The central inputs are wired via floating contacts.
Example for application:
central input 1 / rain detectormotor groups 1+2 / window openermotor groups 3+4 / louver drives.
The central input 1 will be programmed on group 1+2 (LED lightens).The louver will be activated on group 3+4 (LED lightens).If it starts raining now, the window drives will automatically close.If you connect e.g. an external timer to central input 2, you will have activated central input2 for group 3+4 with this, and can only open and/or close the louvers via the timer.
11/16VCM 1004 Rev.:1.2
Programming Function:group allocation vent button inputsVent button inputs as well as IR-remote controls (VIS 10) and D+H bus fields (LF 10-4B) canbe freely allocated to the groups. Possibility of combining groups or of controlling twoVCM 1004 with a remote control.
1 1
1 1 1 1
2 2
2 2 2 2
3 3
3 3 3 3
4 4
4 4 4 4
Group Group
Group Group Group Group
Power Power
Power PowerPower Power
SET SET
SET SET SET SET
1x 1x 1x
*
*
*
* Configurationof vent button inputs
=
=ON
OFF
4
3 Sec.
1
2
3
4
SET
1x
1
2
3
4
12/16 VCM 1004 Rev.:1.2
21 43
1
2
3
4
1
Group
2
Group
3
Group
4
Group
Allocation
Group 1 Group 2
Group 3
Group 4
notconnected
Vent button
Releasegroup
M1 M2 M3 M4
M1 M2
M3
M4
notconnected
notconnected
notconnected
notconnected
notconnected
notconnected
notconnected
notconnected
notconnected
notconnected
notconnected
Group x will be released
Example for Application with one VCM 1004
13/16VCM 1004 Rev.:1.2
1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4
VCM 1004 VCM 10041 2
Gruppe 1
Gruppe 2
Gruppe 3
Gruppe 4
Control level
Group x will be released
Group 1
VCM 1004
Group 2
Group 3
Group 4
VCM 10041 2
notconnected
Group 1 Group 2 Group 3 Group 4 Group 1 Group 2 Group 3 Group 4
ST OP
LÜFTUNG
ST OP
LÜFTUNG
ST OP
LÜFTUNG
ST OP
LÜFTUNG
1VCM 1004
1VCM 1004
2VCM 1004
2VCM 1004
M1
M1
M1
M2
M2
M4
M3
M3
M4
M4
notconnected
notconnected
notconnected
notconnected
notconnected
notconnected
notconnected
notconnected
notconnected
notconnected
notconnected
notconnected
notconnected
notconnected
notconnected
notconnected
notconnected
notconnected
notconnected
notconnected
notconnected
notconnected
notconnected
notconnected
notconnected
Example for Application with two VCM 1004
14/16 VCM 1004 Rev.:1.2
1
2
3
4
1
2
3
4
Group
Power
SETOpening.
Press button .Depending
on configurationOf the group, the electric
drive will automatically up to itsstop position after a single pressing ofthe button or only as long as the buttonis pressed.
open
VCM 1004
ClosingPress buttonDepending on
configurationof the group, the electricdrive will automatically
up to its stop position after a singlepressing of the button or only as longas the button is pressed.
.
close
LED on
StoppenFor stopping of the drive in any intermediateposition press
once again the same running direction buttonsimultaneously the buttons Open and Closed
0 - 2 s. groups are stopped2 - ...s. groups run in Closed-direction
either
or�
�
LED off
< 2 Sec.
Open/ Close/ Stop via Frontfield
15/16VCM 1004 Rev.:1.2
( (
IS 10-4 /LF 10-2A /LF 10-4B
IS 10-4 /LF 10-2A /LF 10-4B
ST OP
Ventilation
ST OP
Ventilation
LT 43 ULT 43 U
(
ST OP
LÜFTUNG
STOP
STOP
STOP
STOP
< 2 Sec.
< 2 Sec.
Opening/ Closing of Groups on VCM 1004
16/16 VCM 1004 Rev.:1.2All sizes in millimetre • Rights to technical modifications reserved. • Reprinting and phototechnicalreproduction also in extracts has to be expressively authorized by D+H Mechatronic AG.
(
LED flashes
Reduction ONBy pressing of button
the temperature set onheating radiator will bereduced by about 6°C.
Reduction OFFBy pressing ofbutton the
reduction of heatingtemperature will be
undone again.
IS 10-4 /LF 10-2A / LF 10-4B
Control „10 Minutes Ventilation“
Control Variostat
(
LED flashes
IS 10-4 /LF 10-2A / LF 10-4B
ST OP
LÜFTUNG When pressing simultanously both thebuttons ( + ) on control panel/ vent
button, automatic ventilation will becarried out, which will be limited to
10 minutes.
.If a Variostat-heating control is
connected as well, the radiator valve willadditionally close complete for
10 minutes. The yellow LED in theVariostat will lighten.
Possibility of closing from this positionany time with button .
(Only if the “safety function” isdeactivated)