Vehicle Controls and Connected Monitoring Solutions
An industry leader for over 30 years, HED specializes in the
design, manufacture, and implementation of innovative control
systems and vehicle monitoring solutions for mobile equipment OEMs.
Along with a complete line of controllers, HMI and telematics our
application development tools provide the flexibility and
configurability to create the optimal control system. Our products
give you ultimate control and complete insights into your vehicle
and entire fleet.
CONTENTS
• Controllers (I/O) • Displays • Keypads • Telematics • Development
Tools • Engineering Services
• Partnerships • Process Focused • Testing and Validation • On-site
Support • Quality & Continuous
Improvement
Jog Dial
3 CL-305-100 5 CL-307-100 7 CL-442-115 9 CL-446-100 11
CL-449-103-XX 13 CL-450-101-XX 17 CL-451-100-XX
19 CL-608-1XX 21 CL-613-1XX 23 CL-614-1XX
25 CL-709-100-XX 27 CL-711-106-XX 30 CL-712-100-XX 33
CL-713-100-XX
35 CL-630
Representative Product Photo
800 398-2224 Fax: 262 673-9455
e-mail:
[email protected] Web: www.hedonline.com Toll-free
technical support: (800) 854-3533
CANLink® CL-305-100 Module Power Module with LED I/O Indicators 8
Outputs and 1 Input including:
• (8) 10A PWM outputs with current limiting
• (1) switch to ground input
• (4) harness codes*
24-pin receptacle.
Connectors: DTM06-12SC
0462-201-20141 20AWG sockets
0462-005-20141 16/18AWG sockets
0413-204-2005 Sealing Plugs – Unused pins are required to be sealed
to maintain module sealing
Operating Voltage Range: 8 to 32 VDC
Operating Temperature: -40°C to 70°C
Storage Temperature: -40°C to 85°C
IP Rating: IP 67
PC Boards: The printed circuit boards are designed for high EMI/RFI
protection.
The boards are conformal coated with a silicone coating for further
water/moisture protection.
All inputs and outputs are protected against shorts to Battery(+)
or Battery(-).
100% of the boards are functionally tested before shipment.
* Harness codes are switch to ground inputs used to identify I/O
module location and function to the master controller
The CL-305 is a solid-state microprocessor based module and member
of the HED® CANLink® multiplexed control family. Delivered in a
Deutsch enclosure, this unit provides a high density I/O count in a
compact and economical package.
Designed for use as a stand alone unit or as part of a distributed
system, the CL-305 is also available in a clear enclosure with LED
indicators for each input or output for simple troubleshooting in
the field.
The HED® CL-305 can be programmed using HED®’s do-it- yourself
CANLink® Composer™ programming tool or directly by HED®
engineering, and is designed for use with the CANLink® Conductor™
software tool for diagnostics and field troubleshooting.
Pin Function Pin Function
1 Output #1 DOUT(+)/PWM(+)(10A)
1 Output #5 DOUT(+)/PWM(+)(10A)
2 BAT(+) Output 5
6 Input #1 STG 6 BAT(+) Output 7
7 BAT(+) Output 2 7 HID#1
8 Output #2 DOUT(+)/PWM(+)(10A)
10 Output #3 DOUT(+)/PWM(+)(10A)
12 Output #4 DOUT(+)/PWM(+)(10A)
12 Output #8 DOUT(+)/PWM(+)(10A)
Note: Above pinout is for HED® part number CL-305-100. Additional
part number data sheets available on HED® website.
2120 Constitution Avenue, Hartford WI 53012 USA Tel:
800 398-2224 Fax: 262 673-9455
e-mail:
[email protected] Web: www.hedonline.com
Information contained on this sheet is accurate at the time of
printing. HED, Inc. reserves the right to change specifications
without notice.
© 2011 HED, Inc. TD-CL305-100-D1
The CL-307 is a solid-state microprocessor based module and member
of the HED® CANLink® multiplexed control family. Delivered in a
Deutsch enclosure, this unit provides a high density I/O count in a
compact and economical package.
Designed for use as a stand alone unit or as part of a distributed
system, the CL-307 is also available in a clear enclosure with LED
indicators for each input or output for simple troubleshooting in
the field.
The HED® CL-307 can be programmed using HED®’s do-it- yourself
CANLink® Composer™ programming tool or directly by HED®
engineering, and is designed for use with the CANLink® Conductor™
software tool for diagnostics and field troubleshooting.
CANLink® CL-307-100 Module
with LED I/O Indicators
8 Outputs and 5 Inputs including:
(8) 2-wire constant current 2A PWM outputs configured as 4
complimentary pairs.
(2) inputs software configurable as switch to ground or
frequency
(3) 10-bit analog inputs
(1) J1939 CAN ports
Connectors: DTM06-12SC
0462-201-20141 20AWG sockets
0462-005-20141 16-18AWG sockets
0413-204-2005 Sealing Plugs – Unused pins are required to be sealed
to maintain module sealing
Operating Voltage Range: 8 to 32 VDC
Operating Temperature: -40°C to 70°C
Storage Temperature: -40°C to 85°C
IP Rating: IP 67
PC Boards: The printed circuit boards are designed for high EMI/RFI
protection.
The boards are conformal coated with a silicone coating for further
water/moisture protection.
All inputs and outputs are protected against shorts to Battery(+)
or Battery(-).
100% of the boards are functionally tested before shipment.
* Harness codes are switch to ground inputs used to identify I/O
module location and function to the master controller
Toll-free technical support: (800) 854-3533
2120 Constitution Avenue, Hartford WI 53012 USA Tel:
800 398-2224 Fax: 262 673-9455
e-mail:
[email protected] Web: www.hedonline.com
CL-307-100 Master Constant Current Module Pinout
Green 12-Pin Connector Brown 12-Pin Connector
Pin Function Pin Function
2 BAT(-) Module 2 Return(-) Outputs 7-8
3 CAN1-H 3 Output #5 DOUT(+)/PWM(+)/CC(+)(2A)
4 CAN1-L 4 Output #6 DOUT(+)/PWM(+)/CC(+)(2A)
5 BAT(+) Outputs 1-4 5 Output #7 DOUT(+)/PWM(+)/CC(+)(2A)
6 BAT(+) Module / Input #6 Battery Voltage
6 Output #8 DOUT(+)/PWM(+)/CC(+)(2A)
7 Output #1 DOUT(+)/PWM(+)/CC(+)(2A)
7 BAT(+) Outputs 5-8
8 Output #2 DOUT(+)/PWM(+)/CC(+)(2A)
9 Output #3 DOUT(+)/PWM(+)/CC(+)(2A)
10 Output #4 DOUT(+)/PWM(+)/CC(+)(2A)
11 Return(-) Outputs 1-2 11 Input #4 STG / FREQ
12 Return(-) Outputs 3-4 12 Input #5 STG / FREQ
Note: Above pinout is for HED® part number CL-307-100. Additional
part number data sheets available on HED® website.
Note: BAT(-) Output pins are required to be connected to system
Battery(-) for proper function of 2-Wire Constant Current Outputs
and for proper suppression of PWM output flyback voltage
spikes
Information contained on this sheet is accurate at the time of
printing. HED, Inc. reserves the right to change specifications
without notice.
© 2011 HED, Inc. TD-CL307-100-C2
Tel: 800 398-2224 Fax: 262 673-9455
e-mail:
[email protected] Web: www.hedonline.com
800 398-2224 Fax: 262 673-9455
e-mail:
[email protected] Web: www.hedonline.com Toll-free
technical support: (800) 854-3533
CANLink® CL-442-115 Module Master I/O Module with LED I/O
Indicators 10 Inputs and 4 Outputs including:
• (8) switch to battery inputs
• (2) 0-5.5VDC 10-bit analog inputs
• (4) 3A PWM outputs with estimated current feedback
• (1) USB port
24-pin receptacle.
Mating Connectors:
0462-201-20141 20AWG sockets
0413-204-2005 Sealing Plugs – Unused pins are required to be sealed
to maintain module sealing
Operating Voltage Range: 8-32 VDC
Operating Temperature: -40°C to 70°C
Storage Temperature: -40°C to 85°C
IP Rating: IP67
PC Boards: The printed circuit boards are designed for high EMI/RFI
protection.
The boards are conformal coated with a silicone coating for further
water/moisture protection.
All inputs and outputs are protected against shorts to Battery(+)
or Battery(-).
100% of the boards are functionally tested before shipment.
* Harness codes are switch to ground inputs used to identify I/O
module location and function to the master controller
The CL-442 is a solid-state microprocessor based module and member
of the HED® CANLink® multiplexed control family. Delivered in a
Deutsch enclosure, this unit provides a high density I/O count in a
compact and economical package.
Designed for use as a stand alone unit or as part of a distributed
system, the CL-442 is also available in a clear enclosure with LED
indicators for each input for simple troubleshooting in the
field.
The HED® CL-442 can be programmed using HED®’s do-it- yourself
CANLink® Composer™ programming tool or directly by HED®
engineering, and is designed for use with the CANLink® Conductor™
software tool for diagnostics and field troubleshooting.
Representative Product Photo
DTM13-12PA (Gray) DTM13-12PB (Black)
Pin Function Pin Function
3 Unswitched Battery(+)** / Input #11 Battery Voltage
3 Output #3 DOUT(+)/PWM(+)/ECC(+)(3A)
9 CAN1-L 9 Input #10 STB
10 CAN1-H 10 USB(DP)
12 BAT(+) Module and Outputs 1-4 / Input #12 Battery Voltage
12 USB(GND)
Note: Above pinout is for HED® part number CL-442-115. Additional
part number data sheets available on HED® website.
**Unswitched vehicle battery must be connected to properly store
data to EEPROM. Module will draw max of 200 micro amps (12V) and
400 micro amps (24V) after turning itself off. This feature is only
available on versions of this module that are Master Module
capable.
2120 Constitution Avenue, Hartford WI 53027 USA Tel:
800 398-2224 Fax: 262 673-9455
e-mail:
[email protected] Web: www.hedonline.com
Information contained on this sheet is accurate at the time of
printing. HED, Inc. reserves the right to change specifications
without notice.
© 2009 HED, Inc. TD-CL442-115-A2
The CL-446 is a solid-state microprocessor based module and member
of the HED® CANLink® multiplexed control family. Delivered in a
Deutsch enclosure, this unit provides a high density and flexible
I/O count in a compact and economical package.
The CL-446 is designed for use as a multi-purpose stand alone unit
or as a master controller or I/O module in a distributed
system.
The HED® CL-446 can be programmed using HED®’s do-it- yourself
CANLink® Composer™ programming tool or directly by HED®
engineering, and is designed for use with the CANLink® Conductor™
software tool for diagnostics and field troubleshooting.
CANLink® CL-446-100 Module
20 Inputs and 8 Outputs including:
(10) Inputs software configurable as switch to battery, switch to
ground or 12-bit analog (0-5.5VDC).
(4) Inputs software configurable as switch to battery, switch to
ground or 12-bit analog (0-11.0VDC).
(4) Inputs software configurable as switch to battery, switch to
ground, 12-bit analog (0-5.5VDC) or RTD (1K ohm)
(2) Inputs software configurable as switch to battery, switch to
ground, 12-bit analog (0-5.5VDC), frequency, PWM or Quadrature
Encoder
o Frequency max is 10KHz at 50% duty cycle
(8) 2A PWM outputs with estimated current feedback o or 2.5A
digital outputs (software configurable as PWM or Digital)
(1) 5VDC Regulated Sensor Supply (500mA)
(2) J1939 CAN ports
(1) USB port (for interfacing to HED® Orchestra™ software
tools)
Specifications
Mating Connectors:
Deutsch
DT06-12SA DT06-12SB DT06-12SC DT06-12SD W12S (wedge) – one per
connector required 0462-201-16141 16AWG sockets 114017 Sealing
Plugs – Unused pins are required to be sealed to maintain module
sealing
Operating Voltage Range:
Storage Temperature: -40°C to 85°C
IP Rating: IP67
PC Boards: The printed circuit boards are designed for high EMI/RFI
protection.
The boards are conformal coated with a silicone coating for further
water/moisture protection.
All inputs and outputs are protected against shorts to Battery(+)
or Battery(-).
100% of the boards are functionally tested before shipment.
Toll-free technical support: (800) 854-3533
2120 Constitution Avenue, Hartford WI 53027 USA Tel:
800 398-2224 Fax: 262 673-9455
e-mail:
[email protected] Web: www.hedonline.com
1 Input #1 STB/STG/VTD/RTD 2
1 BAT(+) Outputs 1-4 / Input #22 Battery Voltage
1 CAN2-L 1 Input #9 STB/STG/VTD
2 Input #2 STB/STG/VTD/RTD 2
2 Output #1 DOUT(+)(2.5A) / PWM/ECC(+)(2A)
2 CAN2-H 2 Input #10 STB/STG/VTD
3 Input #3 STB/STG/VTD/RTD 2
3 Output #2 DOUT(+)(2.5A) / PWM/ECC(+)(2A)
3 No Connect 3 Input #11 STB/STG/VTD
4 Input #4 STB/STG/VTD/RTD 2
4 Output #3 DOUT(+)(2.5A) / PWM/ECC(+)(2A)
4 No Connect 4 Input #12 STB/STG/VTD
5 BAT(+) Module / Input #25 Battery Voltage
5 Output #4 DOUT(+)(2.5A) / PWM/ECC(+)(2A)
5 USB (Power) 3
5 Input #13 STB/STG/VTD 1
6 BAT(-) Module 6 5VDC Sensor Supply (500mA) / Input #21 Sensor
Supply
6 USB (Gnd) 6 Input #14 STB/STG/VTD 1
7 CAN1-L 7 5VDC Sensor Supply Ground 7 USB (DP) 7 Input #15
STB/STG/VTD 1
8 CAN1-H 8 Output #5 DOUT(+)(2.5A) / PWM/ECC(+)(2A)
8 USB (DM) 8 Input #16 STB/STG/VTD 1
9 Input #5 STB/STG/VTD 9 Output #6 DOUT(+)(2.5A) /
PWM/ECC(+)(2A)
9 No Connect 9 Input #17 STB/STG/VTD
10 Input #6 STB/STG/VTD 10 Output #7 DOUT(+)(2.5A) /
PWM/ECC(+)(2A)
10 No Connect 10 Input #18 STB/STG/VTD
11 Input #7 /STG/
12 Input #8 STB/STG/
12 Unswitched Battery(+)
Input #24 Battery Voltage 12 Input #20 STB/STG/VTD
Note: Above pinout is for part number CL-446-100. Different I/O
combinations are available. Additional part number data sheets
available on HED® website.
Note 1: VTD inputs on pins B5-B8 have range of 0-11.0VDC. All other
VTD inputs on this module are 0-5.5VDC. Note 2: RTD ranges are 0-1K
ohm. Note 3: USB cable utilized is required to have a wire between
USB connector Pin 1 and this USB(Power) pin on the HED module. Note
4: Unswitched vehicle battery must be connected to properly store
data to EEPROM when module configured as master module. Module will
draw max of 200 micro amps (12V) and 400 micro amps (24V) after
turning itself off.
Note 5: Early versions of Composer™ require input to be configured
as Pulse Counter when using Encoder input feature. If Composer does
not show Encoder as available option to configure input, select one
of Encoder pins to be Pulse Counter and this will configure two
paired inputs as Encoder. Second pin does not need to be configured
as anything, but can be configured as FREQ if application also
requires the frequency of the Encoder. Both A & B signals from
Encoder are required to be connected to pins 1A and 1B.
Information contained on this sheet is accu rate at the time of
printing. HED, Inc. reserves the right to change specifications
without notice.
© 2012 HED, Inc. TD-CL446-100-B1
800 398-2224 Fax: 262 673-9455
e-mail:
[email protected] Web: www.hedonline.com
The CL-449 is a solid-state microprocessor based module and member
of the HED® CANLink® multiplexed control family. Delivered in a
potted enclosure, this unit provides a flexible I/O count in a
compact and economical package.
The CL-449 is designed for use as a multi-purpose stand alone unit
or as a master controller or I/O module in a distributed
system.
The HED® CL-449 can be programmed using HED®’s do- it-yourself
CANLink® Composer™ programming tool or directly by HED®
engineering, and is designed for use with the CANLink® Conductor™
software tool for diagnostics and field troubleshooting.
CANLink® CL-449-103-XX Module
CL-449-103-11 : Master I/O
CL-449-103-21 : Client I/O
CL-449-103-31 : J1939 Client
4 Outputs and up to 8 Inputs (8 total I/O):
(4) Input software configurable as switch to ground, 12-bit analog,
Frequency, PWM, Counter, Quadrature Encoder or 4-20mA.
o Analog standard range is 0-5.64VDC. Other ranges are possible,
but are set at HED. Contact HED for info.
o Frequency max is 10KHz at 50% duty cycle
(4) pins software configurable as 2A PWM outputs with estimated
current feedback or switch to battery input
o or 2.5A digital outputs (software configurable as PWM or
Digital)
Client Harness Codes* are set in EEPROM. Default is 0x0F (15) o ID
can be changed via CAN message (see page 2)
(1) J1939 CAN port
Mating Connectors:
0462-201-16141 16AWG sockets
114017 Sealing Plugs – Unused pins are required to be sealed to
maintain module sealing
Operating Voltage Range:
Storage Temperature: -40°C to 85°C
IP Rating: IP67
PC Boards: The printed circuit boards are designed for high EMI/RFI
protection.
The boards are conformal coated with a silicone coating for further
water/moisture protection.
All inputs and outputs are protected against shorts to Battery(+)
or Battery(-).
100% of the boards are functionally tested before shipment.
* Harness Codes are used to identify I/O module location and
function to the master controller.
Toll-free technical support: (800) 854-3533
2120 Constitution Avenue, Hartford WI 53027 USA Tel:
800 398-2224 Fax: 262 673-9455
e-mail:
[email protected] Web: www.hedonline.com
11 BAT(-) Module
12 BAT(+) Module and Outputs 1-4 / Input #5 Battery Voltage VTD
(0-32.78VDC)
Note: Above pinout is for HED modules with part number formats of
CL-449-103-XX. Additional part number data sheets available on HED®
website.
Information contained on this sheet is accurate at the time of
printing. HED, Inc. reserves the right to change specifications
without notice.
© 2016 HED, Inc. TD-CL449-103-XX-B1
800 398-2224 Fax: 262 673-9455
e-mail:
[email protected] Web:
Setting Harness Code in EEPROM:
1. Transmit the following message to change Harness Code. a. KK =
old Harness Code b. HH = new Harness Code c. MM = Module ID =
0x0123 (291)
00EF0002 MM MM KK 00 84 00 00 HH
To verify new Harness Code has been set:
2. Cycle power to module.
3. Below message is sent by module on power-up. a. HH = new Harness
Code
00EF0001 - - - - - - HH - - - - - - - -
J1939 Client:
1. Default Node ID is: 0x80 2. Reference HED J9193 Document for
CAN
message used to change Node ID.
The CL-450 is a solid-state microprocessor based module and member
of the HED® CANLink® multiplexed control family. Delivered in an
HED custom enclosure, this unit provides a high density and
flexible I/O count in a compact and economic package.
The CL-450 is designed for use as a multi-purpose stand alone unit
or as a master controller or I/O module in a distributed
system.
The HED® CL-450 can be programmed using HED®’s do-it- yourself
CANLink® Presto™ programming tool or directly by HED® engineering,
and is designed for use with the CANLink® Conductor™ software tool
for diagnostics and field troubleshooting.
CANLink® CL-450-101-XX Module
CL-450-101-10 : Master I/O
CL-450-101-20 : Client I/O
Powerful 32-bit processor
(22) switch to battery inputs
(4) 12-bit analog inputs, dual range software configurable
(4) Inputs software configurable as switch to battery, switch to
ground, 12-bit analog, frequency, PWM, Pulse Counter or AB
Quadrature Encoder
o AB Quadrature Encoder feature not yet available. It will be
available with a future firmware and Orchestra update. Contact HED
for details.
(6) Inputs software configurable as switch to battery, switch to
ground, 12-bit analog, RTD or 4-20mA
o Analog range is 0-5.5VDC. Other ranges are possible, but are set
at HED. Contact HED for info.
o RTD range are 0-500 or 0-2K ohm (3 pins each). Other ranges are
possible, but are set at HED. Contact HED for info.
o Frequency max is 10KHz at 50% duty cycle
(33) pins software configurable as Digital or PWM outputs (8 as
2-Wire Current Feedback and 25 as estimated current feedback)
(up to 3A) 1, or switch to battery input or switch to ground
input
o Option for outputs to be software configured as STB or STG inputs
in banks of 4, 4, 4, 4 and 17 output pins. All pins in a bank must
be configured to same I/O type. Either all as outputs, all as STB
inputs, or all as STG inputs.
(4) Current Return pins for measuring output current
(1) 5VDC Regulated Sensor Supply (250mA)
Client Harness Codes* are set in EEPROM. Default is 0x0F (15) o
Harness Code can be changed with CAN message (see page 4)
(3) J1939 CAN ports
Operating Voltage: 8-32 VDC
IP Rating: IP67
PC Boards: The printed circuit boards are designed for high EMI/RFI
protection.
The boards are conformal coated with a silicone coating for further
water/moisture protection.
All inputs and outputs are protected against shorts to Battery(+)
or Battery(-).
100% of the boards are functionally tested before shipment.
* Harness codes are used to identify I/O module location and
function to the master controller.
Toll-free technical support: (800) 854-3533
2120 Constitution Avenue, Hartford WI 53027 USA Tel:
800 398-2224 Fax: 262 673-9455
e-mail:
[email protected] Web: www.hedonline.com
© 2015 HED, Inc. TD-CL450-101-XX-A2
800 398-2224 Fax: 262 673-9455
e-mail:
[email protected] Web: www.hedonline.com
1 Input #1 STB/STG/
Input #14 STB/STG/ Bank2
Output #9 DOUT(+)/PWM(+)/ECC 1,2
2 Input #2 STB/STG/
Input #15 STB/STG/ Bank2
Output #10 DOUT(+)/PWM(+)/ECC 1,2
3 Input #3 STB/STG/
Input #16 STB/STG/ Bank5
Output #11 DOUT(+)/PWM(+)/ECC 1,2
4 Input #4 STB/STG/
Input #17 STB/STG/ Bank5
Output #12 DOUT(+)/PWM(+)/ECC 1,2
3
6 Unswitched BAT(+) Module 4 and Outputs 1-8 6 BAT(+) Outputs
9-16
7 CAN1-H 7 CAN2-H
8 CAN1-L 8 CAN2-L
9 Input #5 STB/STG/
Input #18 STB/STG/ Bank5
Output #13 DOUT(+)/PWM(+)/ECC 1,2
10 Input #6 STB/STG/
Input #19 STB/STG/ Bank5
Output #14 DOUT(+)/PWM(+)/ECC 1,2
11 Input #20 STB
12 Return(-) Outputs 7 & 8 12 Return(-) Outputs 15 &
16
13 Input #8 STB/STG/
Input #21 STB/STG/ Bank2
Output #15 DOUT(+)/PWM(+)/CC 1,2
14 Input #9 STB/STG/
Input #22 STB/STG/ Bank2
Output #16 DOUT(+)/PWM(+)/CC 1,2
15 Input #10 STB 15 Input #23 STB
16 Input #11 STB 16 Input #24 STB
17 Input #12 STB 17 Input #25 STB
18 Input #13 STB 18 Input #26 STB
1) Quad FET devices are used, so output current is limited in
groups of 4 output pins. If only 1 of 4 outputs is active, max
current is 3.0A in PWM and Digital mode. If all 4 outputs are
active, max current per output is limited to 2.0A in PWM mode and
2.5A in Digital mode. PWM mode assumes 250Hz. Output current may be
increased per channel up to individual max current of 3.0A if not
all channels are active simultaneously or other channels are at a
reduced current. Please contact HED if further information is
needed. It is strongly recommended to level the total output
current across each of the groups as much as possible for best
thermal performance. Output pin groups are: A1/A2/A13/A14,
A3/A4/A9/10, B1/B2/B13/B14, B3/B4/B9/B10
3) Battery (-) must be connected to all four BAT(-) Module pins of
module for outputs to function properly.
4) Unswitched vehicle battery must be connected to properly store
data to EEPROM when module is configured as a master module. Module
will draw less than 1mA after turning itself off. This feature is
only available on versions of this module that are Master Module
capable.
Bank1 through Bank5: All output pins in each bank must all be
configured same. Either all pins in a bank as outputs, all as STB
inputs, or all as STG inputs. Bank1 is comprised of 4 pins, Bank2 4
pins, Bank3 4 pins, Bank4 4 pins, and Bank5 17 pins. If user does
not follow these rules, the pins will not function properly.
Outputs may function correctly, but inputs may not.
CL-450-101-XX Module
1 Input #27 STB/STG/
Input #40 STB/STG/ Bank4
Output #25 DOUT(+)/PWM(+)/ECC 1,2
2 Input #28 STB/STG/
Input #41 STB/STG/ Bank4
Output #26 DOUT(+)/PWM(+)/ECC 1,2
3 Input #29 STB/STG/
Input #42 STB/STG/ Bank5
Input #43 STB/STG/ Bank5
Output #28 DOUT(+)/PWM(+)/ECC 1,2
3
7 CAN3-H 7 Input #44 STB/STG/
Bank5
9 Input #31 STB/STG/
Input #46 STB/STG/ Bank5
Output #30 DOUT(+)/PWM(+)/ECC 1,2
10 Input #32 STB/STG/
Input #47 STB/STG/ Bank5
Output #31 DOUT(+)/PWM(+)/ECC 1,2
12 Return(-) Outputs 23 & 24 12 Return(-) Outputs 32 &
33
13 Input #34 STB/STG/
Input #49 STB/STG/ Bank4
Output #32 DOUT(+)/PWM(+)/CC 1,2
14 Input #35 STB/STG/
Input #50 STB/STG/ Bank4
Output #33 DOUT(+)/PWM(+)/CC 1,2
15 Input #36 STB 15 Input #51 STB
16 Input #37 STB 16 Input #52 STB
17 Input #38 STB 17 Input #53 STB
18 Input #39 STB 18 Input #54 STB
Information contained on this sheet is accurate at the time of
printing. HED, Inc. reserves the right to change specifications
without notice.
© 2015 HED, Inc. TD-CL450-101-XX-A2
800 398-2224 Fax: 262 673-9455
e-mail:
[email protected] Web: www.hedonline.com
CL-450-101-XX Module
1) Quad FET devices are used, so output current is limited in
groups of 4 output pins. If only 1 of 4 outputs is active, max
current is 3.0A in PWM and Digital mode. If all 4 outputs are
active, max current per output is limited to 2.0A in PWM mode and
2.5A in Digital mode. PWM mode assumes 250Hz. Output current may be
increased per channel up to individual max current of 3.0A if not
all channels are active simultaneously or other channels are at a
reduced current. Please contact HED if further information is
needed. It is strongly recommended to level the total output
current across each of the groups as much as possible for best
thermal performance. Output pin groups are: C1/C2/C13/C14,
C3/C4/C9/C10, D1/D2/D13/D14, D3/D4/D9/D10
2) Module output current capacity is limited to 12.5A total for
each 8 outputs combined on each C and D connector. Output current
total for outputs 17-24 is 12.5A and outputs 25-33 is 12.5A.
3) Battery (-) must be connected to all four BAT(-) Module pins of
module for outputs to function properly.
Bank1 through Bank5: All output pins in each bank must all be
configured same. Either all pins in a bank as outputs, all as STB
inputs, or all as STG inputs. Bank1 is comprised of 4 pins, Bank2 4
pins, Bank3 4 pins, Bank4 4 pins, and Bank5 17 pins. If user does
not follow these rules, the pins will not function properly.
Outputs may function correctly, but inputs may not.
Connector E Pin Function
1 Input #55 VTD1(0-5.5V)/VTD2(0-35V)
2 Input #56 VTD1(0-5.5V/VTD2(0-35V)
3 Input #57 VTD1(0-5.5V)/VTD2(0-35V)
4 Input #58 VTD1(0-5.5V)/VTD2(0-35V)
5 5VDC Sensor Supply Ground Input #59 5VDC Sensor Supply Ground
voltage
6 5VDC Sensor Supply (250mA) Input #60 5VDC Sensor Supply
voltage
7 Input #61 STB
8 Input #62 STB
9 Input #63 STB/STG/VTD(0-5.5V)/RTD(500Ohms)/20MA
10 Input #64 STB/STG/VTD(0-5.5V)/RTD(500Ohms)/20MA
13 Input #67 STB/STG/VTD(0-5.5V)/RTD(500Ohms)/20MA
14 Input #68 STB/STG/VTD(0-5.5V)/RTD(2KOhms)/20MA
16 Input #70 STB/STG/VTD(0-5.5V)/RTD(2KOhms)/20MA
17 Input #71 STB/STG/VTD(0-5.5V)/RTD(2KOhms)/20MA
18 Input #72 STB/STG/VTD(0-5.5V)/FREQ/PWM/Count/Encoder(2B) 1
1) AB Quadrature Encoder feature not yet available. It will be
available with a future firmware and Orchestra update. Contact HED
for details.
Information contained on this sheet is accurate at the time of
printing. HED, Inc. reserves the right to change specifications
without notice.
© 2015 HED, Inc. TD-CL450-101-XX-A3
800 398-2224 Fax: 262 673-9455
e-mail:
[email protected] Web: www.hedonline.com
Torque to 72-100 in-lbs
locking patch or liquid is advisable.
Note: Different I/O combinations may be available. Please refer to
specific CL-450-1XX-XX data sheet for I/O number designations for
use within Composer™. Data sheets available on HED® website.
1. Transmit the following message to change Harness Code. a. KK =
old Harness Code b. HH = new Harness Code c. MMMM = Module ID =
0x010B (267)
00EF0002 MM MM KK 00 84 00 00 HH
To verify new Harness Code has been set:
2. Cycle power to module.
3. Below message is sent by module on power-up. a. HH = new Harness
Code
00EF0001 - - - - - - HH - - - - - - - -
The CL-451 is a solid-state microprocessor based module and member
of the HED® CANLink® multiplexed control family. Delivered in a
Deutsch enclosure, this unit provides a high density I/O count in a
compact and economical package.
Designed for use as a stand alone unit or as part of a distributed
system.
The HED® CL-451 can be programmed using HED®’s do-it- yourself
CANLink® Composer™ programming tool or directly by HED®
engineering, and is designed for use with the CANLink® Conductor™
software tool for diagnostics and field troubleshooting.
CANLink® CL-451-100-XX Module
CL-451-100-10 : Master I/O
CL-451-100-20 : Client I/O
Up to 17 Inputs or 16 Outputs (17 total I/O):
Powerful 32-bit processor
Programmable using Presto™ tool. Ladder Logic not supported.
(4) pins software configurable as PWM outputs with estimated
current feedback (up to 3A)
1 , or switch to battery or switch to ground input
(3) pins software configurable as PWM outputs with estimated
current feedback (up to 3A)
1 , or switch to battery, switch to ground or 10-bit
analog input
(1) pin software configurable as PWM output with estimated current
feedback (up to 3A)
1 , or switch to battery, switch to ground, 10-bit analog
or frequency input
o Analog range is 0-5.5VDC. Other ranges are possible, but are set
at HED. Contact HED for info.
(8) pins software configurable as PWM outputs with estimated
current feedback (up to 3A)
1 or switch to battery input or switch to ground input
o All 8 pins must be configured to same I/O type. Either all as
Outputs, all as STB Inputs, or all as STG Inputs
(1) software configurable switch to battery or 10-bit analog
input
Client Harness Codes* are set in EEPROM. Default is 0x0F (15) o
Harness Code can be changed with CAN message (see page 2)
(1) J1939 CAN port
Mating Connectors: Deutsch
Operating Voltage Range: 8-32 VDC
Operating Temperature: -40°C to 70°C
Storage Temperature: -40°C to 85°C
IP Rating: IP67
PC Boards: The printed circuit boards are designed for high EMI/RFI
protection.
The boards are conformal coated with a silicone coating for further
water/moisture protection.
All inputs and outputs are protected against shorts to Battery(+)
or Battery(-).
100% of the boards are functionally tested before shipment.
* Harness Codes are used to identify I/O module location and
function to the master controller.
Toll-free technical support: (800) 854-3533
2120 Constitution Avenue, Hartford WI 53027 USA Tel:
800 398-2224 Fax: 262 673-9455
e-mail:
[email protected] Web: www.hedonline.com
DTM13-12PA (Gray) or -12PC (Green) DTM13-12PB (Black) or -12PD
(Brown)
Pin Function Pin Function
1,2 1
1,2
1,2 2
1,2
1,2 3
1,2
1,2 4
1,2
10 CAN1-H 10 Switched BAT(+) Input #18 Battery Voltage
11 BAT(-) Module 5
11 BAT(-) Module 5
12 Unswitched BAT(+) Module
and Outputs 1-8 12 BAT(+) Outputs 9-16
Information contained on this sheet is accurate at the time of
printing. HED, Inc. reserves the right to change specifications
without notice.
© 2014 HED, Inc. TD-CL451-100-XX-A3
800 398-2224 Fax: 262 673-9455
e-mail:
[email protected] Web: www.hedonline.com
Setting Harness Code in EEPROM:
1. Transmit the following message to change Harness Code. a. KK =
old Harness Code b. HH = new Harness Code c. MMMM = Module ID =
0x00FE (254)
00EF0002 MM MM KK 00 84 00 00 HH
To verify new Harness Code has been set:
2. Cycle power to module.
3. Below message is sent by module on power-up. a. HH = new Harness
Code
00EF0001 - - - - - - HH - - - - - - - -
Note: Different I/O combinations are available. Please refer to
specific CL-451-1XX-XX data sheet for I/O number designations for
use within Composer™. Data sheets available on HED® website.
1) Quad FET devices are used, so output current is limited in
groups of 4 output pins. If only 1 of 4 outputs is active, max
current is 3.0A in PWM and Digital mode. If all 4 outputs are
active, max current per output is limited to 1.5A in PWM mode and
2.0A in Digital mode. PWM mode assumes 250Hz. Output current may be
increased per channel up to individual max current of 3.0A if not
all channels are active simultaneously or other channels are at a
reduced current. Please contact HED if further information is
needed. Output pin groups are A1-A4, A5-A8, B1-B4, B5-B8. It is
strongly recommended to level the total output current across each
of the groups as much as possible for best thermal
performance.
2) Module output current capacity is limited to 10A total for each
8 outputs combined on each A and B connector. Output current total
for outputs 1-8 is 10A and outputs 9-16 is 10A.
3) These 8 pins must have all I/O assigned in as same I/O type.
Either all as Outputs, all as STB Inputs, or all as STG
Inputs.
4) Unswitched vehicle battery must be connected to properly store
data to EEPROM when module is configured as a master module. Module
will draw less than 1mA after turning itself off. This feature is
only available on versions of this module that are Master Module
capable.
5) Battery (-) must be connected to both BAT(-) Module pins of
module for outputs to function properly.
Customizable Icons
The HED® CL-608 is a solid-state microprocessor based keypad module
that is a member of the HED® CANLink® multiplex control family. It
provides a versatile, programmable, and highly visible operator
interface.
Designed for use as part of a distributed system, the CL-608 can
dramatically reduce vehicle dashboard wiring, and can be programmed
with a dimming function.
Each button is available in various colors. Additionally, buttons
can be programmed to flash codes for simple troubleshooting and
warning indications.
The HED® CL-608 can be programmed using HED’s do-it- yourself
CANLink® Composer™ programming tool or directly by HED®
engineering, and is designed for use with the CANLink® Conductor™
software tool for diagnostics and field troubleshooting.
CANLink® CL-608-1XX 4x3 Keypad
Sealed CAN Keypad Family
Special Features include:
(12) Multiplexed rubber membrane pushbuttons o Also available: 2x3,
2x4 & 2x6 keypads
Sealed construction (IP67)
Capable of detecting multiple simultaneous key presses
Dimmable LED indicators (via CAN or Analog Input)
Dimmable LED backlit icons (via CAN or Analog Input)
Optional Power LED indicator
Customizable button labeling / icons
Customizable LED indicator location & color o 3 LED indicators
per button o 1 LED indicator between each pair of buttons
- used for bar graph feature
Optional 2nd Connector for one of following features: o Easy
daisy-chain connection of multiple keypads o 4 pins for various
combinations of Inputs / Outputs o 4 pins can be used as harness
code inputs
(1) J1939 CAN port
Deutsch
DT06-4S (with W4SA wedge) DT06-4S (with W4SB wedge) 0462-201-16141
16AWG Sockets
Operating Voltage Range: 8 to 32 VDC
Operating Temperature: -40°C to 70°C
Storage temperature: -40°C to 85°C
IP Rating IP67
PC Boards: The printed circuit boards are designed for high EMI/RFI
protection.
The boards are conformal coated with a silicone coating for further
water/moisture protection.
All inputs and outputs are protected against shorts to Battery(+)
or Battery(-).
100% of the boards are functionally tested before shipment.
* Harness codes are switch to ground inputs used to identify I/O
module location and function to the master controller.
Toll-free technical support: (800) 854-3533
2120 Constitution Avenue, Hartford WI 53027 USA Tel:
800 398-2224 Fax: 262 673-9455
e-mail:
[email protected] Web: www.hedonline.com
2 BAT(-) Module
3 CAN-H
4 CAN-L
Information contained on this sheet is accurate at the time
of
printing. HED®, Inc. reserves the right to change specifications
without notice.
© 2011 HED®, Inc. TD-CL608-000-A4
800 398-2224 Fax: 262 673-9455
e-mail:
[email protected] Web: www.hedonline.com
B Connector Option #2
Deutsch DT06-4PB 4-pin Connector
3 CAN-H
4 CAN-L
Note: This B connector configuration allows for daisy-chaining of
wire harnesses for applications using multiple keypads. When daisy
chaining, customer is required to install 10A fuse to initial
+Battery feeding first keypad.
B Connector Option #1
Deutsch DT06-4PB 4-pin Connector
3 Input STB / STG or Output DOUT/PWM/ECC(+) (2A)
4 Input STB / STG or Output DOUT/PWM/ECC(+) (2A)
Note: Different feature combinations are available. Please refer to
specific CL-608-1XX data sheet for feature number designations for
use within Composer™. Data sheets available on HED® website.
Note: 2A Output PWM frequency is limited to max of 500Hz. Duty
cycle range limited to: 10% to 90%.
Composer I/O Assignments for Button Inputs & LED Outputs
Composer Input numbering for each Button is shown on drawing.
Composer Output numbering for each LED indicator is shown on
drawing.
Each button is available in various colors. Additionally, buttons
can be programmed to flash codes for simple troubleshooting and
warning indications.
The HED® CL-613 is offered as a J1939 or CANLink client, or can be
programmed directly by HED® engineering.
CANLink® CL-613-1XX 2x8 Keypad
Sealed CAN Keypad Family
(16) Multiplexed rubber membrane pushbuttons o Also available: 2x4
keypad
J1939 protocol (CANopen coming soon)
Sealed construction (IP67)
Large buttons
Dimmable LED indicators
Dimmable LED backlit icons
Customizable button labeling / icons
Customizable LED indicator location & color o 3 LED indicators
per button o 1 LED indicator between some pairs of buttons
- used for bar graph feature
(1) Digital switch to battery input
(1) Sinking output (300mA)
(1) J1939 CAN port
Amp
Amp 776433-3 776299-2 16-18AWG Sockets 776363-1 Sealing Plug –
Unused pins are required to be sealed to maintain product
sealing
Operating Voltage Range: 8 to 32 VDC
Operating Temperature: -40°C to 70°C
Storage temperature: -40°C to 85°C
IP Rating IP67
PC Boards: The printed circuit boards are designed for high EMI/RFI
protection.
All inputs and outputs are protected against shorts to Battery(+)
or Battery(-).
100% of the boards are functionally tested before shipment.
Toll-free technical support: (800) 854-3533
2120 Constitution Avenue, Hartford WI 53027 USA Tel:
800 398-2224 Fax: 262 673-9455
e-mail:
[email protected] Web: www.hedonline.com
6 CAN-L
Information contained on this sheet is accurate at the time of
printing. HED®, Inc. reserves the right to change specifications
without notice.
© 2014 HED®, Inc. TD-CL613-000-A3
800 398-2224 Fax: 262 673-9455
e-mail:
[email protected] Web: www.hedonline.com
Each button is available in various colors. Additionally, buttons
can be programmed to flash codes for simple troubleshooting and
warning indications.
The HED® CL-614 is offered as a J1939 or CANLink client, or can be
programmed directly by HED® engineering.
CANLink® CL-614-1XX 2x4 Keypad
Sealed CAN Keypad Family
(8) Multiplexed rubber membrane pushbuttons o Also available: 2x8
keypad
J1939 protocol (CANopen available soon)
Sealed construction (IP67)
Large buttons
Dimmable LED indicators
Dimmable LED backlit icons
Customizable button labeling / icons
Customizable LED indicator location & color o 3 LED indicators
per button o 1 LED indicator between some pairs of buttons
- used for bar graph feature
(1) Digital switch to battery input
(1) Sinking output (300mA)
(1) J1939 CAN port
Amp
Amp 776433-3 776299-2 16-18AWG Sockets 776363-1 Sealing Plug –
Unused pins are required to be sealed to maintain product
sealing
Operating Voltage Range: 8 to 32 VDC
Operating Temperature: -40°C to 70°C
Storage temperature: -40°C to 85°C
IP Rating IP67
PC Boards: The printed circuit boards are designed for high EMI/RFI
protection.
All inputs and outputs are protected against shorts to Battery(+)
or Battery(-).
100% of the boards are functionally tested before shipment.
Toll-free technical support: (800) 854-3533
2120 Constitution Avenue, Hartford WI 53027 USA Tel:
800 398-2224 Fax: 262 673-9455
e-mail:
[email protected] Web: www.hedonline.com
6 CAN-L
Information contained on this sheet is accurate at the time of
printing. HED®, Inc. reserves the right to change specifications
without notice.
© 2014 HED®, Inc. TD-CL614-000-A3
800 398-2224 Fax: 262 673-9455
e-mail:
[email protected] Web: www.hedonline.com
Color displays from 4.3" - 10.1"
The CL-709 is a solid-state Freescale Spectrum microcontroller
based display and member of the HED® CANLink® multiplexed control
family. Delivered in a plastic enclosure, this unit provides
communication messages to the end-user.
The CL-709 is designed for use as a stand alone unit or as part of
a distributed system.
The HED® CL-709 can be programmed using HED®’s do-it-yourself
CANLink® Arranger™ programming tool or directly by HED®
engineering. The Spectrum processor design allows for immediate CAN
communication on power-up for communication with other CAN modules
in the system.
CANLink® CL-709-100-XX Display
CL-709-100-10 : Master
CL-709-100-20 : Client
Sealed enclosure for external mounting (panel & RAM mount
capable)
Sunlight readable 4.3” TFT Color LCD display
WQVGA 480x272 pixel format
Freescale Spectrum controller for CAN and I/O
16MB FLASH for graphics, 1MB FLASH for logic, 48KB RAM
Real Time Clock with Internal Battery
Navigation Key (4 button)
Low Power Sleep Mode with Wake-Up by following methods: Digital
Input on Connector, CAN Traffic, Time set by software using Real
Time Clock
I/O Available:
(1) USB port (allows software updates directly from USB memory
device) o FAT32 USB memory device supported (not NTFS)
(2) J1939 CAN ports
(1) 5V Sensor Supply
(1) Wake-Up pin (STB) or input software configurable as switch to
battery or switch to ground
(1) input software configurable as switch to battery or switch to
ground
(4) inputs software configurable as switch to battery, witch to
ground, analog, RTD, Frequency, PWM or Encoder
(4) 2A PWM Outputs w/ Estimated Current Feedback or 3A Digital
Outputs or software configurable as switch to battery or
ground
Specifications
Mating Connectors:
Deutsch (I/O)
RAMCO (USB)
DT16-18SA-K004 0462-201-16141 (socket for 16-18 AWG wire)
0462-209-16141 (socket for 14-16 AWG wire) 114017 Sealing Plug
0413-217-1605 Locking Sealing Plug Note: Unused pins require plugs
to maintain module sealing
PLM-V84A (USB: M8 4-pin Male Connector) (or other manufacture of
IP67 sealed M8 connector)
Operating Voltage: 8 to 32 VDC
Operating Temperature: -40°C to 70°C
* Graphic updates are slower for first 5 minutes if cold start at
temperatures below -30°C.
Storage Temperature: -40°C to 80°C
IP Rating: IP67 (with M8 sealing cap installed)
PC Boards: Printed circuit boards are designed for high EMI/RFI
protection.
The boards are conformal coated with a silicone coating for further
water/moisture protection.
Toll-free technical support: (800) 854-3533
2120 Constitution Avenue, Hartford WI 53027 USA Tel:
800 398-2224 Fax: 262 673-9455
e-mail:
[email protected] Web: www.hedonline.com
5 BAT(-) Module
6 Unswitched +Battery** Module and Outputs / Input #9 Battery
Voltage (0-32.5V)
7 CAN1-H
8 CAN1-L
9 5VDC Sensor Supply Ground / Input #8 5V Sensor Supply Gnd
(0-6V)
5VDC Sensor Supply / Input #7 5V Sensor Supply Voltage (0-6V)
11 Wake-Up (STB Input) / Input #6 STB/STG
12 Input #5 STB/STG
15 Input #4
STB/STG/VTD(0-5.5V)/RTD(0-2Kohm)/FREQ/PWM/Encoder(1A)
16 Input #3
STB/STG/VTD(0-5.5V)/RTD(0-2Kohm)/FREQ/PWM/Encoder(1B)
17 Input #2
STB/STG/VTD(0-5.5V)/RTD(0-500ohm)/FREQ/PWM/Encoder(2A)
18 Input #1
STB/STG/VTD(0-5.5V)/RTD(0-500ohm)/FREQ/PWM/Encoder(2B)
Note: Above pinout is for HED® part number CL-709-100-XX.
Additional part number data sheets may be available on HED®
website.
**Unswitched vehicle battery must be connected for controlled
shutdown and to properly store data to EEPROM. Display will draw
<1mA after turning itself off.
Information contained on this sheet is accurate at the time of
printing. HED, Inc. reserves the right to change specifications
without notice.
© 2014 HED, Inc. TD-CL709-100-XX-C4
800 398-2224 Fax: 262 673-9455
e-mail:
[email protected] Web: www.hedonline.com
2 Input #23 STG
3 Input #24 STG
4 Input #25 STG
Real Time Clock (RTC)
Year Input #10 VTD (0-5000mV) 0 – 255
(1900–2155)
Day of Month
Day of Week
Hour Input #14 VTD (0-5000mV) 0 – 23
Minute Input #15 VTD (0-5000mV) 0 – 59
Second Input #16 VTD (0-5000mV) 0 – 59
LCD and Button Backlights
USB Seal Cap Torque:
20 oz-in
Note: If removing cap to program, cap and rubber washer must be re-
installed to above torque to maintain IP67 seal.
RAM Mount option:
National Products, Inc. www.rammount.com Part Number:
RAM-B-238U
Use size 8-32 fasteners, with max depth of 0.340”, and min depth of
0.250” into display.
The CL-711 is a solid-state Cortex A8 ARM microcontroller based
display and member of the HED® CANLink® multiplexed control family.
Delivered in a plastic enclosure, this unit provides communication
messages to the end-user.
The CL-711 is designed for use as a stand alone unit or as part of
a distributed system.
The HED® CL-711 can be programmed using HED®’s do- it-yourself
CANLink® Arranger™ programming tool or directly by HED®
engineering. The dual processor design allows for immediate CAN
communication on power-up for communication with other CAN modules
in the system.
CANLink® CL-711-106-xx Display
CL-711-106-XX-000 : Standard Mount, No Touch
CL-711-106-XX-030 : Standard Mount, Touch
CL-711-106-XX-130 : Front Mount, Touch
CL-711-106-XX-150 : Front Mount, No Buttons, Touch
XX : 10 = Master, 20 = Client ; 00 = Open Platform
Features: Sealed enclosure for external mounting
Panel and RAM mount capable
Sunlight readable 7.0” TFT Color LCD display
WVGA 800x480 pixel format (152.4mm x 91.44mm)
LED Backlight with 1000 cd/m 2 (nits) brightness
Cortex A8 ARM Microprocessor running at 800MHz
4GB eMMC FLASH
512MB DDR3 RAM
Real Time Clock with Internal Battery (15 year life -
typical)
4 Video inputs. NTSC & PAL supported.
Video Window location and size are programmable with graphics
sharing remainder of screen
Graphics can be drawn over top of video window
Dual processor allows for CAN communication immediately on
power-up
Navigation key for easy menu manipulation
No Touch Screen (optional – see other CL-711 part numbers)
Ambient light sensor
Low Power Sleep Mode with Wake-Up by following methods: Digital
Input on Connector, CAN Traffic, Time set by software using Real
Time Clock
I/O Available: (1) USB Host (capable of supplying up to 250mA to
device)
o Allows for software updates directly from USB Memory Device
(1) USB Client (for interfacing to HED software tools)
(2) J1939 CAN ports
(12) Connector pins that can be hardware configured to be various
combinations inputs and/or outputs, including switch to ground,
switch to battery, analog, frequency, PWM, Encoder inputs or
sourcing outputs.
(1) 5VDC Sensor Supply (250mA)
Specifications
Mating Connectors:
Deutsch DT16-18SA-K004 (for Power, CAN and I/O) RAMCO M12 4 & 8
pin Female (for USB, Video) (or other manufacturer of IP67 sealed
M12 connector)
Operating Voltage: 8 to 32 VDC
Operating Temperature: -40°C to 70°C
* Graphic updates are slower for first 5 minutes if cold start at
temperatures below -30°C.
Storage Temperature: -40°C to 80°C
IP Rating: IP67
2120 Constitution Avenue, Hartford WI 53027 USA Tel:
800 398-2224 Fax: 262 673-9455
e-mail:
[email protected] Web: www.hedonline.com
© 2014 HED®, Inc. TD-CL711-106-A2-2
800 398-2224 Fax: 262 673-9455
e-mail:
[email protected] Web: www.hedonline.com
5 Battery(-)
7 CAN1-H
8 CAN1-L
11 Input #3 STB/STG/Wake-Up
12 Input #4 STB/STG/VTD(0-5.6V)
17 5VDC Sensor Supply Gnd / Input #7 Supply Gnd Voltage
18 5VDC Sensor Supply / Input #8 Sensor Supply Voltage
Note: Different I/O combinations are available. Please refer to
specific CL-711-101-xx data sheet for I/O number designations for
use within Composer™. Data sheets available on HED® website.
**Unswitched vehicle battery must be connected for controlled
shutdown to properly store data to EEPROM, and for Lower Power
Sleep and Wake-Up to function properly. Display will draw <1mA
after turning itself off.
Composer Input Assignments for Button Press Reading
Button # Composer Input #
* Note: Button 1 is left most button.
Composer Output Assignments for LCD and Button Backlights
Function Composer Output #
LCD Backlight
Output #6 DOUT(+)/PWM(+) 6 kHz
Note: For proportional control of Backlight, the output should be
configured as PWM. Digital control would only allow for Off and
Full On control.
Composer Input Assignments for Real Time Clock (RTC) Items
RTC Item Composer
Input # Valid Data
(1900 – 2155)
Day of Month
Day of Week
Hour Input #23 VTD (0-5000mV) 0 – 23
Minute Input #24 VTD (0-5000mV) 0 – 59
Second Input #25 VTD (0-5000mV) 0 – 59
Note: RTC values are not able to be set (changed) with Ladder
Logic. It is able to be set with Presto.
Composer Input Assignment For Ambient Light Sensor
Function Composer
Input #26 VTD (0-4095mV) 0 – 4095
Setting Client Harness Code in EEPROM:
1. Transmit the following message to change Harness Code. a. KK =
old Harness Code b. HH = new Harness Code c. MM = Module ID =
0x0104 (260)
00EF0002 MM MM KK 00 84 00 00 HH
To verify new Harness Code has been set:
2. Cycle power to module.
3. Below message is sent by module on power-up. a. HH = new Harness
Code
00EF0001 - - - - - - HH - - - - - - - -
1 USB (Power)
2 USB (DM)
3 USB (DP)
4 USB (Ground)
Information contained on this sheet is accurate at the time of
printing. HED®, Inc. reserves the right to change specifications
without notice.
© 2017 HED®, Inc. TD-CL711-106-XX-A2-2
800 398-2224 Fax: 262 673-9455
e-mail:
[email protected] Web: www.hedonline.com
A Not Used N/A D
B Not Used N/A A
C USB Client M12 Female – 4 pin – Gold contacts A
D Not Used N/A A
E USB Host M12 Female – 4 pin – Gold contacts A
F Video Inputs - #1 & #2 M12 Female – 4 pin – Gold contacts
B
G Video Inputs - #3 & #4 M12 Female – 4 pin – Gold contacts
B
RAM Mount option:
National Products, Inc. www.rammount.com Part Number:
RAM-202U
Use size 10-24 fasteners, with max depth of 0.420” and min depth of
0.300” into display.
Torque to 30-40 in-lbs
The CL-712 is a solid-state Cortex A8 ARM microcontroller based
display and member of the HED® CANLink® multiplexed control family.
Delivered in a plastic enclosure, this unit provides communication
messages to the end-user.
The CL-712 is designed for use as a stand alone unit or as part of
a distributed system.
The HED® CL-712 can be programmed using HED®’s do- it-yourself
CANLink® Arranger™ programming tool or directly by HED®
engineering. The dual processor design allows for immediate CAN
communication on power-up for communication with other CAN modules
in the system.
CANLink® CL-712-100-xx Display
CL-712-100-20-001 : Client
CL-712-100-00-001 : Open Platform
Features: Open Platform allows for Qt Lite programming
environment
Sealed enclosure for external mounting
Panel and RAM mount capable
Sunlight readable 10.1” TFT Color IPS LCD display
IPS LCD for
LED Backlight with 1000 cd/m 2 (nits) brightness
Cortex A8 ARM Microprocessor running at 800MHz
8GB eMMC FLASH (option for 16GB, 32GB – with minimum order
required)
512MB DDR3 RAM (option for 1GB – with minimum order required)
Real Time Clock with Internal Battery (15 year life -
typical)
4 Video inputs. NTSC & PAL supported.
Video Window location and size are programmable with graphics
sharing remainder of screen
Graphics can be drawn over top of video window
Dual processor allows for CAN communication immediately on
power-up
Navigation key for easy menu manipulation
Touch Screen (optional)
Ambient light sensor
Low Power Sleep Mode with Wake-Up by following methods: Digital
Input on Connector, CAN Traffic, Time set by software using Real
Time Clock
I/O Available: (1) USB Host (capable of supplying up to 250mA to
device)
o Allows for software updates directly from USB Memory Device
(1) USB Client (for interfacing to HED software tools)
(1) Ethernet 10/100 Base-T (only available in open platform
programming)
(2) J1939 CAN ports
(12) Connector pins of I/O, including switch to ground, switch to
battery, analog, frequency, PWM, Encoder inputs or sourcing
outputs.
(1) 5VDC Sensor Supply (250mA)
Specifications
Mating Connectors:
Deutsch DT16-18SA-K004 (for Power, CAN and I/O) RAMCO M12 4 & 8
pin Female (for USB, Video) (or other manufacturer of IP67 sealed
M12 connector)
Operating Voltage: 8 to 32 VDC
Operating Temperature: -40°C to +70°C (12VDC w/ all I/O
active)
-40°C to +70°C (24VDC w/ No I/O active)
-40°C to +65°C (24VDC w/ 2 Outputs & 2 STB Inputs active)
-40°C to +60°C (24VDC w/ all I/O active)
* Graphic updates are slower for first 5 minutes if cold start at
temperatures below -30°C.
Storage Temperature: -40°C to 80°C
IP Rating: IP67
2120 Constitution Avenue, Hartford WI 53027 USA Tel:
800 398-2224 Fax: 262 673-9455
e-mail:
[email protected] Web: www.hedonline.com 30
© 2016 HED®, Inc. TD-CL712-100-XX-A9
800 398-2224 Fax: 262 673-9455
e-mail:
[email protected] Web: www.hedonline.com
2 Output #2 DOUT/PWM/ECC/(+)(2A) / Input #46 STB/STG
3 Output #3 DOUT/PWM/ECC/(+)(2A) / Input #47 STB/STG
4 Output #4 DOUT/PWM/ECC/(+)(2A) / Input #48 STB/STG
5 Battery(-)
7 CAN1-H
8 CAN1-L
11 Input #3 STB/STG/Wake-Up
12 Input #4 STB/STG/VTD(0-5.6V)
15 Input #5 STB/STG/VTD(0-5.6V)/FREQ/PWM/Encoder2(Freq)
16 Input #6 STB/STG/VTD(0-5.6V)/FREQ/PWM/Encoder2(Direction)
17 Input #7 STB/STG/VTD(0-5.6V)
18 Input #8 STB/STG/VTD(0-5.6V)
Note: Different I/O combinations may be available. Please refer to
specific CL-712-1xx-xx data sheet for I/O number designations for
use within Composer™. Data sheets available on HED® website.
**Unswitched vehicle battery must be connected for controlled
shutdown to properly store data to EEPROM, and for Lower Power
Sleep and Wake-Up to function properly. Display will draw <1mA
after turning itself off.
Button Press Inputs
Button # Composer Input #
5 Input #18 STG
6 Input #50 STG
7 Input #51 STG
8 Input #52 STG
9 Input #53 STG
* Note: Button 1 is top-left button, button 6 is top-right. Buttons
1-5 down left side, buttons 6-9 down right side.
LCD and Button Backlights
Button Output #5 DOUT(+)/PWM(+) 250 Hz
Backlight Output #6 DOUT(+)/PWM(+) 6 kHz
Note: For proportional control of Backlight, the output should be
configured as PWM. Digital control would only allow for Off and
Full On control.
Composer Input Assignments for Real Time Clock (RTC) Items
RTC Item Composer
Input # Valid Data
(1900 – 2155)
Day of Month
Day of Week
Hour Input #23 VTD (0-5000mV) 0 – 23
Minute Input #24 VTD (0-5000mV) 0 – 59
Second Input #25 VTD (0-5000mV) 0 – 59
Note: RTC values are not able to be set (changed) with Ladder
Logic. It is able to be set with Presto.
Ambient Light Sensor
Input #26 VTD (0-4095mV) 0 – 4095
Setting Client Harness Code in EEPROM:
1. Transmit the following message to change Harness Code. a. KK =
old Harness Code b. HH = new Harness Code c. MM = Module ID =
0x011D (285)
00EF0002 MM MM KK 00 84 00 00 HH
To verify new Harness Code has been set:
2. Cycle power to module.
3. Below message is sent by module on power-up. a. HH = new Harness
Code
00EF0001 - - - - - - HH - - - - - - - -
Note: If Client device has already established communication with
CANLink Master, device will not respond to this CAN message to set
Harness Code.
1 USB (Power)
2 USB (DM)
3 USB (DP)
4 USB (Ground)
Information contained on this sheet is accurate at the time of
printing. HED®, Inc. reserves the right to change specifications
without notice.
© 2016 HED®, Inc. TD-CL712-100-XX-A9
800 398-2224 Fax: 262 673-9455
e-mail:
[email protected] Web: www.hedonline.com
A Ethernet (open platform only)
M12 Female – 4 pin – Gold contacts D
B Not Used N/A A
C USB Client M12 Female – 4 pin – Gold contacts A
D Not Used N/A A
E USB Host M12 Female – 4 pin – Gold contacts A
F Video Inputs - #1 & #2 M12 Female – 4 pin – Gold contacts
B
G Video Inputs - #3 & #4 M12 Female – 4 pin – Gold contacts
B
RAM Mount option:
Torque to 30-40 in-lbs
Fasteners should have max depth of 0.280” and min depth of 0.220”
into display.
Ethernet Connector
The CL-713 is a solid-state Cortex A7 ARM microcontroller based
display and member of the HED® CANLink® multiplexed control
family.
The CL-713 is designed for use as a stand alone unit or as part of
a distributed system.
CANLink® CL-713-100-xx Display 5.0” Color Display
Standard Features: Linux Operating System Programming Tools
Supported:
o Crank Storyboard o CODESYS o Open Platform
Cortex-A7 ARM Microprocessor running at 800MHz 4GB eMMC Flash
o Option for 8GB – with min order required 512MB DDR3 RAM Sealed
enclosure for external mounting Panel and RAM mount capable LCD
Optically bonded to hardened glass lens with AR film Sunlight
readable 5.0” TFT Color LCD display 800x480 pixel resolution LED
Backlight with 800 cd/m2 (nits) brightness Ambient Light Sensor (2)
CAN ports (1) USB OTG (capable of supplying up to 500mA to
device)
o Software updates directly from USB Memory Device o Interface to
PC software tools
Low Power Sleep Mode with Wake-Up by following methods: Digital
Input on Connector, CAN Traffic, Time set by software using Real
Time Clock, Button press
Optional Features: PCAP Touch Screen (option)
o Works with moisture and gloves! Real Time Clock with Internal
Battery (option, 15 year life - typical) (1) Ethernet 10/100 Base-T
(option) 2 Video inputs. NTSC & PAL supported. (option)
o 1 shown on LCD at a time (not simultaneously) o Video Window
location and size are programmable with graphics
sharing remainder of screen WiFi & Bluetooth (option)
o Dual-band WiFi 802.11 o Bluetooth 4.2 + BLE
I/O Available (Optional): Discrete Inputs and Outputs (shown on
next page)
Specifications Operating Voltage: 6 to 32 VDC
Operating Temperature:
-40°C to +70°C
* Graphic updates are slower for first 5 minutes if cold start at
temperatures below -30°C.
Storage Temperature: -40°C to 80°C
IP Rating: IP67
Toll- technical support: (800) 854-3533
2120 Constitution Avenue, Hartford WI 53027 USA Tel: 800 398-2224
Fax: 262 673-9455
e-mail:
[email protected] Web: www.hedonline.com
© 2019 HED®, Inc. TD-CL713-100-XX-A8-PRELIMINARY
2120 Constitution Avenue, Hartford WI 53027 USA Tel: 800 398-2224
Fax: 262 673-9455
e-mail:
[email protected] Web: www.hedonline.com
Deutsch 18-Pin DT Pin Function 1 Output #1 DOUT(+)(2A) /
PWM(+)/ECC/(+)(2A) / Input #11 STB/STG
2 Output #2 DOUT(+)(2A) / PWM(+)/ECC/(+)(2A) / Input #12
STB/STG
3 Output #3 DOUT(+)(2A) / PWM(+)/ECC/(+)(2A) / Input #13
STB/STG
4 Output #4 DOUT(+)(2A) / PWM(+)/ECC/(+)(2A) / Input #14
STB/STG
5 Battery(-)
7 CAN1-H
8 CAN1-L
11 Input #3 STB/STG/Wake-Up
12 Input #4 STB/STG/VTD(0-5.6V)
15 Input #5 STB/STG/VTD(0-5.6V)/FREQ/PWM/Encoder(2A)
16 Input #6 STB/STG/VTD(0-5.6V)/FREQ/PWM/Encoder(2B)
17 5VDC Sensor Supply Gnd / Input #7 Supply Gnd Voltage / Input #9
STB/STG/VTD(0-5.6V)
18 5VDC Sensor Supply / Input #8 Sensor Supply Voltage / Input #10
STB/STG/VTD(0-5.6V)
Note: Different I/O combinations may be available. Please refer to
specific CL-713-1xx-xx data sheet for I/O number designations. Data
sheets available on HED® website.
**Unswitched vehicle battery must be connected for controlled
shutdown to properly store data to EEPROM, and for Lower Power
Sleep and Wake-Up to function properly. Display will draw <1mA
after turning itself off.
Inputs & Outputs (Optional)
Torque to 30-40 in-lbs
Fasteners should have max depth of 0.280” and min depth of 0.220”
into display.
T: 1-800-398-2224 | International 001-262-673-9450 | E-mail:
[email protected] | HEDonline.com
H
2120 Constitution Ave. Hartford, WI 53027 USA
HED Inc. offers you some of the most robust keypads on the market.
Our CL-630 jog dial is no exception, giving you a clean
ergonomic interface for displays and other vehicle system with its
5 push buttons and center jog dial that offers a rotary
en-coder, joystick encoder and pushbutton encoder putting
everything right at your fingertips.
Functionality:
Navigate your displays with the push or turn of a button.
Customizable functionality based on your system needs.
Features:
Rotary encoder, with 2 axis switched joystick and entire know is
also a pushbutton
5 additional pushbuttons
Long Life: 500,000 cycles (every action of touch switch and
rotary switch)
Operating Temperature –40°C o 85°C
Storage Temperature –40°C o 85°C
Temperature range subject to use case. HED assumes heat
dissipation
based on general market software and solution use cases.
35
CL-630 Jog Dial Rotary Encoder w/ 2 Axis Joystick and push
buttons
T: 1-800-398-2224 | International 001-262-673-9450 | E-mail:
[email protected] | HEDonline.com
H
Standards/Certifications
EMC
Transient Emissions Annex D and E, 30MHz to 1GHz ISO 13766
Conducted Transients All test pulse in Annex A table A1 for 12V
system and Table A2 for 24 V systems ISO 7637-2
Absorbed-Lined Chamber Absorbed-lined chamber 100V/M, 10MHz to 2GHz
ISO 11452-2
Bulk Current Injection 100mA, 20MHZ to 400MHz ISO 11452-2
ESD ± 15kV air discharges, ± 8kV contact discharges ISO 10605
Electrical
Over Voltage 36VDC for 60 minutes ISO 16750-2
Short Circuit Protection All outputs to ground for 60 seconds ISO
16750-2
Reverse Polarity Protection 28VDC for 60 seconds ISO 16750-2
Starting Profile Class A ISO 16750-2
Withstand Voltage 500 Vrms with a duration of 60 seconds ISO
16750-2
Insulation Resistance 500 VDC with a duration of 60 seconds ISO
16750-2
Superimposed Alternating Voltage Superimposed alternating voltage:
UPP, of 4 VAC ISO 16750-2 4.4
Slow Decrease and Increase of Sup-
ply Voltage
Increase the supply voltage from 0V to Usmin, then decrease it from
Usmin to 0V, applying a
change rate of 0.5 V/min linear.
ISO 16750-2
Monmentary Drop in Supply Voltage Apply the test pulse accoding to
ISO 16750-2 (figure 4 for 12V system, figure 5 for 24V
systems)
Mechanical
Random Vibration Test Fh Method 1, random excitation at 10, 150,
220 and 350Hz breakpoint frequencies, 5
hours in each axis.
IEC 60068-2-64
General Vibration Sweep sine wabe from 5-500Hz, ± 15mm amplitude,
50 20 cycles in each plane. IEC 60068-2-6
Sinusoidal Vibration Sinusoidal from 10 to 2000Hz, 5 minutes at
resonant point. IEC 60068-2-6
Shock/Crash Safety 100 shocks in each direction of the 3 axis(600
total) at 400 m/s2 for 6 ms IEC 60068-2-27
Drop Test Ec Free Fall—Procedure 1 drop in each direction of the 3
axes (6 total) from 1000mm IEC 60068-2-31
Environmental
Storage Temperature1 -40C 4 hours; +85C 4 hours
Thermal, Hot Soak Test Bb, +85ºC for 96 hours IEC 60068-2-2
Thermal, Cold Soak Test Ab, -40ºC for 96 hours IEC 60068-2-1
Thermal Shock Test Na –40ºC to +85ºC 10 cycles for 10 hours IEC
60068-2-14
Solar Radiation2 1000 hours, test method Cycle 1, 0.51W/m2*nm at
340nm, per cycle
102 mins light / 18 mins light and spray, BP temp. 65ºC, air temp.
38ºC, RH 50%
ISO 4982-2
Ingress Protection IP67 ISO 20653
Humidity, soak Test cab, 30ºC at 93% RH for 10 days IEC
60068-2-78
Humidity, cyclic Test Db Method 1, 55 to 25 at 90% RH 6 cycles of
24 hours each IEC 60068-2-30
Chemical Resistance2 ISO 16750 Method II(Brushing) for engine oil,
hydraulic oil, diesel fuel, grease and urea at
room temperature for 24 hours.
ISO 16750-5
Thermal Cycling Test Nb, -40ºC to 85ºC, dwell: 3 hours;
Transfer rate: (3±0.6ºC)/min, 2 cycles
IEC 60068-2-14
T: 1-800-398-2224 | International 001-262-673-9450 | E-mail:
[email protected] | HEDonline.com
2120 Constitution Ave. Hartford, WI 53027 USA
Pinout - (DT06-4S)
Pin Function
Seal Plug – Deutsch P/N: 114017
Mounting
Mounting bolts should be torqued between 20 and 25 in-lb. There are
3 x M5
bolts on the under side of the jog dial.
HED is headquartered in Hartford, WI, just outside of Milwaukee.
Our professional mindset centers on disciplined ISO-based
processes, continuous improvement and
innovation. Our company culture works hard and plays hard. Our
teams are dedicated and deeply integrated to partner with you and
offer the best experience in
developing your vehicle control solution.
HED TD-CL305-100-D1
HED TD-CL307-100-C2
HED TD-CL442-115-A2
HED TD-CL446-100-B1
HED TD-CL449-103-XX-B1
HED TD-CL450-101-XX-A3
HED TD-CL451-100-XX-A3
HED TD-CL608-000-A4
HED TD-CL613-000-A3
HED TD-CL614-000-A3
HED TD-CL709-100-XX-C4
HED TD-CL711-106-XX-A2-2
HED TD-CL712-100-XX-A9
HED TD-CL713-100-XX-PRELIMINARY-CONFIDENTIAL-A8