TR 5-6
TR 7-8
TR 19-20
TR 22
TR 17-18
LOMA VISTA ROAD
ANNEX 3
ANNEX 4
REQUIREMENTS OF CALIFORNIA ADMINISTRATIVE CODE, TITLE 24
TRUE NORTH ANGLE, RELATIVE TO "REFERENCE NORTH" SHOWN ON
THE BUILDER SHALL PROVIDE THE OWNER WITH INSTRUCTIONS ON
THE EFFICIENT USE OF LIGHTING AND MECHANICAL SYSTEM
VENTURA COUNTY COMMUNITY COLLEGE DISTRICT
VENTURA COLLEGE
GENERAL REQUIREMENTS
2.
CONSTRUCTION:
2013 CBC - CALIFORNIA BUILDING CODE
2013 CEC - CALIFORNIA ELECTRICAL CODE
2013 CPC - CALIFORNIA PLUMBING CODE
2013 CMC - CALIFORNIA MECHANICAL CODE
2013 CEnC - CALIFORNIA ENERGY CODE
2013 CFC - CALIFORNIA FIRE CODE
2013 CAC - CALIFORNIA ADMINISTRATIVE CODE
2013 CALIFORNIA REFERENCED STANDARDS CODE
NUMBER OF EXITS: 6
HEIGHT: SINGLE- STORY
FIRE SPRINKLERS EXISTING: NONE
THE PLANS: +
COMPONENTS.
3.
APPLICABLE CODES
HUNDRED SQUARE FEET OF WALL AREA. ITEMS WHICH PENETRATE
BE INSTALLED ANY CLOSER TOGETHER THAN ONE PER EVERY ONE
ANY ITEMS WHICH PENETRATE FIRE RATED WALLS MUST BE EITHER
FIRE PROTECTION
FIRE RATED WALLS MUST BE SEPARATED BY A HORIZONTAL
DISTANCE OF TWENTY-FOUR INCHES WHEN ON OPPOSITE SIDES
FERROUS OR COPPER AND FIRE-STOPPED. ELECTRICAL OUTLET
BOXES INSTALLED IN FIRE RATED WALLS SHALL BE STEEL, SHALL
NOT EXCEED SIXTEEN SQUARE INCHES IN AREA, AND SHALL NOT
CALIFORNIA MECHANICAL CODE AND CBC SECTION 710.5.
WIRING WITHIN CONCEALED SPACES SHALL COMPLY WITH THE
PROJECT ANALYSIS
APN:
ZONING:
LOT AREA:
TENANT SPACE:
OFFICES:
VENTURA COLLEGE
OCCUPANCY: E
CODE ANALYSIS
xx
xx
XX SQ. FT.
XX SQ. FT.
OF A WALL.
2.
1.
CONSTRUCTION IS TO COMPLY WITH ALL APPLICABLE
SCOPE OF THE WORK
1.
TITLE 24 - ENERGY
ARCHITECTURAL
A-0
A-1
A-2
A-3
A-4
A-5
A-6
ELECTRICAL
E-100
E-150
E-300
E-400
E-401
E-402
E-600
PLUMBING
P-1
P-2
P-3
MECHANICAL - HVAC
M-1
COVER SHEET
KEY PLAN
AEC: DEMOLITION PLANS
AEC: (N) MEN'S / WOMEN'S FLOOR PLANS
INTERIOR RESTROOM ELEVATIONS
SELECTED DETAILS
TYPICAL ACCESSIBILITY DETAILS
ELECTRICAL COVER SHEET / NOTES
ELECTRICAL SITE PLAN / KEY PLAN
ELECTRICAL LIGHT FIXTURE SCHEDULE
ELECTRICAL DEMOLITION PLANS
ELECTRICAL POWER / LIGHTING PLANS
ELECTRICAL PANEL SCHEDULE
ELECTRICAL DOOR ACTIVATOR DETAIL
PLUMBING COVER SHEET
AEC PLUMBING FLOOR PLANS
SELECTED PLUMBING DETAILS
AEC / C: MECHANICAL DUCT PLANS
SHEET INDEX
VICINITY MAP
FIN FLR FINISHED FLOOR ELEVATION
CONT CONTINUOUSALT. ALTERNATEFBO FURNISHED BY OTHERS
CSMNT. CASEMENT
CATV CABLE TELEVISION
C.I. CAST IRON
CLG CEILING
A/C AIR CONDITIONING
ANNOD. ANNODIZED
ARCH('L) ARCHITECT(URAL)
AUTO. AUTOMATIC
B.M. BENCHMARK
B.U.R. BUILT UP ROOF
BTTM. BOTTOM
CAB'T CABINET
BLDG. BUILDING
AL. ALUMINUM
BTWN. BETWEEN
D.F. DOUGLAS FIR
(E) EXISTING
ENCL ENCLOS(UR)E
EQ EQUAL
CU FT CUBIC FEET
DIA DIAMETER
DIM DIMENSION
DISP DISPENSER
DIV DIVISION
D DEPTH
DWG DRAWING
CFM CUBIC FEET PER MINUTE
DEMO DEMOLISH, DEMOLITION
D.H. DOUBLE HUNG
DS DOWN SPOUT
HORIZ HORIZONTAL
HB HOSE BIBB
I.D. INSIDE DIAMETER
INSUL INSULATION
GA GAGE, GAUGE
GALV GALVANIZED
GL. GLASS, GLAZING
GB. GLASS BLOCK
HDBD. HARD BOARD
HD HEAVY DUTY
HC HOLLOW CORE
HM HOLLOW METAL
FUT FUTURE
HWD HARDWOOD
HT. HEIGHT
ABBREVIATIONS
DRAWING SYMBOLS
ADJ. ADJACENT
ASS'Y. ASSEMBLY
A.B. ANCHOR BOLT
DETAILS
CMU CONCRETE MASONRY UNIT
CONC. CONCRETE
COL COLUMN
DETAILS
BUILDING SECTIONS
FLUOR. FLUORESCENT
FTG. FOOTING
N I C NOT IN CONTRACT
SHT SHEET
VERT VERTICAL
STD. STANDARD
S.H. SINGLE HUNG
S C SOLID CORE
SPEC('S). SPECIFICATION(S)
SQ FT SQUARE FOOT
T.S. TUBE SECTION
SST' L STAINLESS STEEL
THK THICKNESS
T&G. TONGUE AND GROOVE
PTDF PRESSURE TREATED DOUGLAS FIR
PSF POUNDS PER SQUARE FOOT
PSI. POUNDS PER SQUARE INCH
PL. PLATE, PROPERTY LINE
PWD PLYWOOD
PTN PARTITION
PLAS LAM PLASTIC LAMINATE
N.T.S. NOT TO SCALE
O C ON CENTER
OPNG. OPENING
OPP OPPOSITE
O D OUTSIDE DIAMETER
O'HEAD OVERHEAD
PH PHONE
TYP TYPICAL
SYS. SYSTEM
ST'L. STEEL
SIM SIMILAR
SECT. SECTION
R O ROUGH OPENING
ROW RIGHT OF WAY
NWF. NATURAL WOOD FINISH
LIN FT LINEAL FOOT
(N) NEW
LTWT LIGHT WEIGHT
GRID / COLUMN REFERENCE LINE
A
1
DATUM / LEVEL LINE
RF ROOF
(F.G) FINISH GRADE
(T.P.) TOP OF PAVEMENT
POINT ELEVATIONS
CONSULTANTS
ELECTRICAL ENGINEER: LUCCI & ASSOCIATES
KEN LUCCI
3251 CORTE MALPASO #
CAMARILLO, CALIFORNIA 93012-8094
805.389.6520
15-007:AEC: COVER
AEC: EVENT CENTER
MEN & WOMEN
RESTROOM
COVER SHEET
SCOPE OF WORK:
COMPLETE RENOVATION / ALTERATION OF FOUR (E) RESTROOMS. THE WORK INCLUDES
NEW PLUMBING FIXTURES, PRIVACY TOILET PARTITIONS, GRAB BARS, HAND DRYERS,
RESTROOM ACCESSORIES, HARDWARE, LIGHTING FIXTURES, SELF-PRIMING FLOOR DRAINS,
CERAMIC FLOOR AND WALL TILES, AND PAINTING.
AT THE TIME THIS BUILDING WAS CERTIFIED FOR OCCUPANCY, IT COMPLIED WITH ALL
APPLICABLE CODE REQUIREMENTS. IT IS TECHNICALLY INFEASIBLE TO MEET FULL
COMPLIANCE WITH ALL ACCESSIBILITY REQUIREMENTS. AN EXCEPTION IS GRANTED
UNDER CBC, SECT. 11B-202.3, EXCEPTION 2, AND TITLE-24, SECT. 202 TO COMPLY WITH
ACCESSIBILITY STANDARDS TO THE MAXIMUM EXTENT FEASIBLE.
DEMO NOTES
REMOVE ALL (E) PLUMBING FIXTURES, ENCLOSURES, WALL TILES, LIGHTING, AND
PARTITION WALLS WHERE SHOWN. PREP ALL COMPONENTS IN ORDER TO INSTALL
NEW PLUMBING LINES, FIXTURES AND PARTITIONS AT LOCATIONS SHOWN. EXPOSE STUD
FRAMING TO INSPECT AS-BUILT CONDITION. REPAIR AND REINFORCE FRAMING AND
BLOCKING AS NECESSARY.
VENTURA COUNTY
COMMUNITY
COLLEGE DISTRICT
VENTURA COLLEGE
4667 Telegraph Road
Ventura, CA 93003
AEC GYMNASIUM
MEN & WOMEN
RESTROOM
RENOVATION
PROJECT DIRECTORY
SOILS ENGINEER / SEPTIC SYSTEM:
XXXX
CIVIL ENGINEER:
XXXX
STRUCTURAL ENGINEER:
XXXX
ELECTRICAL ENGINEER:
LUCCI & ASSOCIATES
805/389.6520
MECHANICAL ENGINEER:
A/E GROUP
805/653.1722
LANDSCAPE ARCHITECT:
XXXX
WATER SYSTEM / FIRE PROTECTION SYSTEM:
XXXXt
THIS PLAN IS BASED UPON DATA COMPILED
AND FURNISHED BY OTHERS.
BUILDING AND SAFETY - SUBMITTAL
SHEET NAME
DATE
SCALE
PROJECT
SHEET NUMBER OF SHEETS
C15 - 007
00
ROY E COLBERT
ARCHITECTURE
PLANNING
DESIGN
353 SAN JON ROAD
VENTURA, CA 93001
805 / 650 . 9590 PH
805 / 650 . 9589 FX
CALIFORNIA C12050
N.C.A.R.B.
AS SHOWN
This project has been designed by me, or
under my direct supervision.
PRELIMINARY - NOT FOR CONSTRUCTION
PLANNING - SUBMITTAL
.
ISSUED FOR CONSTRUCTION
1. THE INTERNATIONAL SYMBOL OF ACCESSIBILITY SIGN SHALL BE DISPLAYED AT ALL
ACCESSIBLE RESTROOM FACILITIES AND AT ACCESSIBLE BUILDING ENTRANCES
UNLESS ALL ENTRANCES ARE ACCESSIBLE. INACCESSIBLE ENTRANCES SHALL
HAVE DIRECTIONAL SIGNS INDICATING THE NEAREST ACCESSIBLE ENTRANCE.
2. RECEPTACLES ON WALLS SHALL BE MOUNTED NO LESS THAN 18" ABOVE FINISH
FLOOR. EXCEPTION: HEIGHT LIMITATIONS DO NOT APPLY WHERE THE USE OF
SPECIAL EQUIPMENT DICTATES OTHERWISE, OR WHERE ELECTRICAL
RECEPTACLES ARE NOT NORMALLY INTENDED.
3. WHERE EMERGENCY WARNING SYSTEMS ARE PROVIDED, THESE SYSTEMS SHALL
INCLUDE BOTH AUDIBLE AND VISUAL ALARMS. THE VISUAL ALARMS SHALL BE
LOCATED THROUGHOUT, INCLUDING RESTROOMS, AND PLACED EITHER 80" ABOVE
FINISH FLOOR OR 6" BELOW FINISH CEILING, WHICHEVER IS LOWER.
4. DOORS TO ALL ACCESSIBLE SPACES SHALL HAVE ACCESSIBLE HARDWARE
(ie.: LEVER-OPERATED, PUSH AND U-SHAPED PULLS) INSTALLED AT 48" A.F.F.
5. FLOOR SURFACE (TILE) SHALL BE INSTALLED TO TO BE STABLE, FIRM AND SLIP
RESISTANT. CHANGES IN LEVEL BETWEEN
1
4
" AND
1
2
" SHALL BE BEVELED WITH A
SLOPE NO GREATER THAN 1:2. CHANGES IN LEVEL GREATER THAN
1
2
" REQUIRE A
RAMP. GRATINGS IN A FLOOR SURFACE SHALL HAVE SPACES NO GREATER THAN
1
2
" WIDTH. DOORWAY THRESHOLDS AND SADDLES SHALL NOT EXCEED
1
2
" HEIGHT.
6. GRAB BARS REQUIRED FOR ACCESSIBILITY SHALL BE 1
1
4
" - 1
1
2
" DIAMETER WITH
1
1
2
" CLEAR SPACE BETWEEN THE BAR AND THE WALL.
7. ACCESSIBLE WATER CLOSETS SHALL BE 17" - 19" FROM FLOOR TO TOP OF SEAT.
GRAB BARS SHALL BE 36" LENGTH LOCATED BEHIND THE WATER CLOSET AND 42"
LENGTH LOCATED ALONG THE SIDE, AND SHALL BE 33" - 36" ABOVE FINISH FLOOR.
8. ACCESSIBLE URINALS SHALL BE STALL TYPE OR WALL-HUNG TYPE, EACH
WITH ELONGATED RIMS AT 17" ABOVE FINISH FLOOR.
9. ACCESSIBLE LAVATORIES SHALL BE INSTALLED WITH THE RIM AT 34" MAX. ABOVE
FINISH FLOOR AND A CLEARANCE OF 29" MIN. A.F.F. TO UNDERSIDE OF THE APRON.
10. ACCESSIBLE SINKS SHALL BE INSTALLED WITH THE RIM AT 34" MAX. A.F.F. AND A
CLEARANCE OF 27" MIN. HEIGHT x 30" WIDTH x 19" DEPTH UNDER THE SINK. THE
SINK DEPTH SHALL BE 6
1
2
" DEPTH.
11. HOT WATER AND DRAIN PIPING UNDER ACCESSIBLE LAVATORIES AND SINKS
SHALL BE INSULATED OR OTHERWISE CONFIGURED TO PROTECT AGAINST
CONTACT. THERE SHALL BE NO SHARP NOR ABRASIVE SURFACES AND EDGES
UNDER ACCESSIBLE LAVATORIES AND SINKS.
12. ACCESSIBLE LAVATORIES AND SINKS SHALL HAVE ACCESSIBLE FAUCETS AND
VALVESETS (ie.: LEVER-OPERATED, PUSH-TYPE, ELECTRONICALLY CONTROLLED).
13. WHEN MIRRORS ARE INSTALLED IN RESTROOMS, AT LEAST ONE SHALL BE
INSTALLED WITH THE BOTTOM EDGE OF THE MIRRORED SURFACE AT 40" MAX. AFF
ACCESSIBILITY NOTES
1. THE DRAWINGS ARE INTENDED ONLY TO CONVEY DESIGN INTENT. THE PLANS AND SPECIFICATIONS SHALL
NOT BE CONSIDERED AS EITHER A LIST OF PARTS OR ASSEMBLY INSTRUCTIONS. THE SPECIFICATIONS ARE
INCLUDED WITH THESE DRAWINGS AND DEFINE ADDITIONAL WORK TO BE ACCOMPLISHED.
2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REVIEW OF ALL OF THE CONTRACT DOCUMENTS, TO
EXAMINE THE PROJECT SITE AND TO FAMILIARIZE HIMSELF WITH THE TOTAL SCOPE OF THE WORK AND THE
INTENT OF THE CONTRACT DOCUMENTS. IT IS INCUMBENT UPON THE THE CONTRACTOR TO NOTIFY THE
ARCHITECT IMMEDIATELY UPON THE DISCOVERY OF ANY DISCREPANCIES OR CONFLICTS IN THE CONTRACT
DOCUMENTS.
3. DURING THE BIDDING PROCESS THE CONTRACTOR SHALL OBTAIN PROPER WRITTEN CLARIFICATION OF
DISCREPANCIES, CONFLICTS, AND/OR UNCLEAR ITEMS PRIOR TO THE SUBMISSION OF THE BID.
4. DURING CONSTRUCTION, THE CONTRACTOR SHALL NOT PROCEED WITH THE INSTALLATIONS OR
APPLICATIONS OF ANY CONSTRUCTION THAT MAY BE AFFECTED BY DISCREPANCIES AND/OR CONFLICTS
UNTIL SUCH ISSUES ARE RESOLVED.
5. IT SHALL BE UNDERSTOOD THAT ALL CONTRACTORS AND THEIR PERSONNEL ARE PROPERLY TRAINED AND
EXPERIENCED TO PERFORM THE CONSTRUCTION WORK, AND TO OTHERWISE CARRY OUT THE INTENT OF
THE WORK INCORPORATED INTO THE CONSTRUCTION DRAWINGS AND SPECIFICATIONS.
6. THE CONTRACT DOCUMENTS CONSIST OF THE THE COMPLETE PLAN DRAWINGS, SPECIFICATIONS, REPORTS,
BIDDING INFORMATION AND OTHER INFORMATION PREPARED BY THE ARCHITECT, THE ARCHITECT'S
CONSULTANTS, OR CONSULTANTS HIRED BY THE OWNER. IN THE EVENT OF DISCREPANCIES OR CONFLICTS
IN THE CONTRACT DOCUMENTS, THE INFORMATION CONTAINED IN THE WRITTEN SPECIFICATIONS SHALL
TAKE PRECEDENCE OVER THE DRAWINGS, AND FURTHER, LARGE SCALE DETAIL DRAWINGS SHALL TAKE
PRECEDENCE OVER THE SMALLER SCALE DRAWINGS.
7. WHERE ANY SPECIFIED MATERIAL OR PROCESS IS INDICATED ON THE DRAWINGS OR IN THE
SPECIFICATIONS, IT IS FOR THE PURPOSE MAKING CLEAR THE INTENT REQUIRED TO ACCOMPLISH THE
SCOPE OF THE PROJECT. THE CONTRACTOR MAY OFFER A SUITABLE MATERIAL OR PROCESS TOGETHER
WITH ALL SUPPORTING DOCUMENTATION TO VALIDATE THE EQUIVALENT NATURE TO THE SATISFACTION OF
THE ARCHITECT, THE CONSULTING ENGINEERS, AND TO VENTURA COLLEGE.
8. EACH CONTRACTOR SHALL BE RESPONSIBLE FOR TOTAL COORDINATION OF THEIR OWN WORK AND WITH
THE WORK OF ALL OTHER TRADES. THE CONTRACTOR SHALL PERSONALLY SUPERVISE AND DIRECT THE
PROJECT. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL METHODS OF CONSTRUCTION,
TECHNIQUES, SEQUENCES AND PROCEDURES. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR THE
SAFETY AND PERFORMANCE OF THE WORK, AND FULL COMPLIANCE WITH O.S.H.A., THE U.S. DEPT. OF
LABOR, THE STATE OF CALIFORNIA, AND THE VENTURA COUNTY COMMUNITY COLLEGE DISTRICT
REGULATIONS.
9. ALL THE WORK SHALL CONFORM WITH THE REQUIREMENTS OF THE 2013 EDITION OF THE CALIFORNIA
BUILDING CODE (CBC), AS WELL AS WITH ALL OTHER APPLICABLE FEDERAL REGULATIONS, STATE CODES,
LOCAL CODES, ORDINANCES AND REGULATIONS.
10. ONLY THE APPROVED DRAWINGS WITH THE STATEMENT "ISSUED FOR CONSTRUCTION" ON THE COVER
SHEET ARE TO BE USED FOR CONSTRUCTION ON THIS PROJECT. CONTRACTORS USING OTHER THAN THE
APPROVED DRAWINGS SHALL BE SOLELY RESPONSIBLE FOR SUCH WORK.
11. ALL DIMENSIONS SHOWN ON THE PLAN VIEWS OF THE DRAWINGS ARE TO THE STRUCTURAL FACE OF WALLS,
OR TO THE CENTERLINE OF WALLS, UNLESS NOTED OTHERWISE. DIMENSIONS TO FINISH SURFACES SHALL
BE NOTED AS SUCH.
12. DO NOT SCALE THE DRAWINGS. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS IN THE
FIELD, AND SHALL IMMEDIATELY REPORT ANY DISCREPANCIES OR VARIATIONS TO THE ARCHITECT AND TO
THE OWNER'S REPRESENTATIVE.
13. THE CONTRACTOR SHALL REPAIR AND REPLACE ALL PROPERTY THAT MAY BE DAMAGED BY WORK UNDER
THIS CONTRACT TO THE SATISFACTION OF THE DIRECTOR OF FACILITIES, MAINTENANCE & OPERATIONS OF
VENTURA COLLEGE AND THE ARCHITECT. ALL PIPING, CONDUITS, LINES, ETC., THAT MAY BE ENCOUNTERED
SHALL BE ADEQUATELY SUPPORTED AND PROTECTED UNTIL PERMANENT SUPPORT AND PROTECTION IS
APPROVED, OR UNTIL REMOVAL IS AUTHORIZED.
14. ALL GLAZING SHOWN TO BE INSTALLED IN HAZARDOUS AREAS SHALL COMPLY WITH THE PROVISIONS OF
CBC CHAPTER 24.
15. THE CONTRACTOR SHALL VERIFY ALL ELECTRICAL AND MECHANICAL LOADS THAT IS SCHEDULED TO BE
GENERATED BY THE TENANT'S EQUIPMENT SHOWN ON THE DRAWINGS AND/OR SPECIFIED PRIOR TO
ORDERING THE EQUIPMENT. INFORMATION REGARDING ITEMS THAT MAY AFFECT THE ARCHITECTURAL
NATURE OR STRUCTURE OF THE PROJECT OR EXISTING CONSTRUCTION SHALL BE BROUGHT TO THE
ATTENTION OF THE ARCHITECT IMMEDIATELY.
16. ALL FIRE RESISTIVE CONSTRUCTION SHALL COMPLY WITH THE PROVISIONS OF CBC CHAPTER 7, AND SHALL
BE CONSTRUCTED OF LISTED WALL, FLOOR AND CEILING ASSEMBLIES PER CBC CHAPTER 7, SECTION 716,
AND TABLES 720.1(1), 720.1(2), 720.1(3), AND ADDITIONAL APPROVED ASSEMBLIES LISTED BY THE "GYPSUM
ASSOCIATION DESIGN MANUAL", LATEST EDITION. THESE PROVISIONS INCLUDE LIMITATIONS OF SIZE, TYPE
AND INDIVIDUAL FIRE RATING OF THE PENETRATING ITEM OR ASSEMBLY. NOTE THAT ADDITIONAL
THROUGH-WALL AND MEMBRANE PENETRATIONS SHALL BE PROVIDED WITH "F" AND "T" FIRE BLOCKING AS
DESCRIBED IN CBC CHAPTER 7 FOR THE METHOD OF PENETRATION BEING USED.
17. WALL AND CEILING MATERIALS SHALL NOT EXCEED THE FLAME SPREAD CLASSIFICATIONS IN CBC, TABLE
803.5.
18. ALL STRUCTURAL HOLD-DOWNS SHALL BE SET IN PLACE BY THE USE OF A TEMPLATE PRIOR TO ANY
FOUNDATION INSPECTION. SEE THE STRUCTURAL SHEAR SCHEDULE FOR THE SIZES AND SPACING OF
ANCHOR BOLTS.
19. THE ARCHITECT OR ENGINEER SHALL PERFORM ON-SITE OBSERVATIONS FOR COMPLIANCE WITH THE PLANS
AND SPECIFICATIONS.
20. EACH CONTRACTOR SHALL GUARANTEE, BE RESPONSIBLE FOR, AND MAKE GOOD ANY AND ALL DEFECTS
DUE TO FAULTS OF HIS RESPECTIVE TRADE FOR ALL LABOR, MATERIALS, OR LEAKS FOR ONE (1) YEAR
MINIMUM COMMENCING UPON ACCEPTANCE OF THE COMPLETED PROJECT BY THE BOTH THE ARCHITECT
AND THE DIRECTOR OF FACILITIES, MAINTENANCE AND OPERATIONS OF VENTURA COLLEGE
.
21. THE CONTRACTOR SHALL FURNISH AND BE RESPONSIBLE FOR ADEQUATE SHORING, BRACING, PERIMETER
CHAIN LINK FENCING, AND ALL OTHER PROTECTIVE MEASURES NECESSARY TO SAFELY EXECUTE THE
COMPLETE CONSTRUCTION WORK.
OPEN TO GYMNASIUM BELOW
FIXED SEATING
EXERCISE AREA
ENTRY LOBBY
TICKETS
VENTURA COUNTY
COMMUNITY
COLLEGE DISTRICT
VENTURA COLLEGE
4667 Telegraph Road
Ventura, CA 93003
AEC GYMNASIUM
MEN & WOMEN
RESTROOM
RENOVATION
PROJECT DIRECTORY
SOILS ENGINEER / SEPTIC SYSTEM:
XXXX
CIVIL ENGINEER:
XXXX
STRUCTURAL ENGINEER:
XXXX
ELECTRICAL ENGINEER:
LUCCI & ASSOCIATES
805/389.6520
MECHANICAL ENGINEER:
A/E GROUP
805/653.1722
LANDSCAPE ARCHITECT:
XXXX
WATER SYSTEM / FIRE PROTECTION SYSTEM:
XXXXt
THIS PLAN IS BASED UPON DATA COMPILED
AND FURNISHED BY OTHERS.
BUILDING AND SAFETY - SUBMITTAL
SHEET NAME
DATE
SCALE
PROJECT
SHEET NUMBER OF SHEETS
C15 - 007
00
ROY E COLBERT
ARCHITECTURE
PLANNING
DESIGN
353 SAN JON ROAD
VENTURA, CA 93001
805 / 650 . 9590 PH
805 / 650 . 9589 FX
CALIFORNIA C12050
N.C.A.R.B.
AS SHOWN
This project has been designed by me, or
under my direct supervision.
PRELIMINARY - NOT FOR CONSTRUCTION
PLANNING - SUBMITTAL
.
ISSUED FOR CONSTRUCTION
15-007:AEC: A-1
A-2: AEC DEMO PLAN
A-4: AEC IMPROVEMENT PLAN
A-2: AEC DEMO PLAN
A-4: AEC IMPROVEMENT PLAN
SCALE:
1
32
" = 1'-0"
UPPER LEVEL FLOOR PLAN
AEC BLDG
AEC: EVENT CENTER
MEN & WOMEN
RESTROOM
KEY PLANS
AEC: EVENT CENTER
MEN & WOMEN
RESTROOMS
DEMO FLOOR PLANS
DEMO KEY NOTES
(E) 8-INCH CONCRETE WALL TO REMAIN
D4
D2
D3
D1
D7
D6
D5REMOVE (E) TILE FLOORING & REPAIR MORTAR
BED
D8
D9
(E) 2x8 WOOD STUD PARTITION TO REMAIN
REINFORCE AS REQ'D FOR STABILITY
D10
D11
D12
D13
D14
D15
D16
D17
D18
D19
D20
D21
(E) 2x4 WOOD STUD PARTITION TO REMAIN
REINFORCE AS REQ'D FOR STABILITY
REMOVE (E) FLOOR DRAIN & WASTE LATERAL
SAWCUT AS REQUIRED
(E) 2x6 WOOD STUD PARTITION TO REMAIN
REINFORCE AS REQ'D FOR STABILITY
D22
REMOVE (E) WALL TILE & BACKING
(E) 4-INCH CAST IRON WASTE LATERAL (DOWN)
TO REMAIN
REMOVE (E) 3-INCH C.I. WASTE LATERAL
REMOVE (E) 2-INCH C.I. WASTE LATERAL
(E) 2-INCH V.T.R. (UP) TO REMAIN
(E) 3-INCH CAST IRON WASTE LATERAL (DOWN)
TO REMAIN
(E) 2-INCH CAST IRON WASTE LATERAL (DOWN)
TO REMAIN
REMOVE (E) WALL HUNG URINALS
REMOVE (E) WALL HUNG LAVATORIES
REMOVE (E) WALL HUNG TOILETS
REMOVE (E) TOILET ENCLOSURE PARTITIONS
REMOVE (E) PLASTER CEILING AND WOOD FRAMED
SOFFITS
REMOVE (E) ACCESSORIES: SHELVES/MIRRORS/
TOWEL DISPENSERS/ ETC.
28'-10
3
4
"
6'-0"
22'-10
3
4
"
20'-6"
17'-1"
3'-5"
7'-7
3
4
"
11'-6"9'-9"
D1 D10 D12
D4 D6
D14
D4 D6
F.D.
D7
F.D.
D7
F.D.
D7
D2D1 D4
D5
D5
D5
D5
D5
D18
D18
D18
D18
D18
REMOVE (E) PRIVACY PARTITION
D19
D19
D16
D16
D16
D15 D15 D15 D15 D15 D15 D15 D15 D15D15
D5
D16 D16D16D16 D16
D14
D17
D17
D17
D17
D17
D17
D6D3
SAWCUT 4" CONCRETE SLAB
TO EXPOSE U.G. DRAIN LINES
D11 D11
D10
D10
D11
D11
D11
D6D3
D8
D8
D9
SAWCUT 4" CONCRETE SLAB
TO EXPOSE U.G. DRAIN LINES
D8
D12
D17
D17
D17
D17
D17
D17
D17
D17
D17
D17
D14 D14
D18
D18
D18
D18
D18
D18
D18
D18
F.D.
D7
F.D.
D7
D11D11
D5
D5
D5
D5
D5
D5
D25D6
D1
D14
D14
D4 D6
D4 D2
D1
21'-3
1
2
"
19'-1
1
2
"
1'-1"1'-1"
14'-6"
3'-5
3
4
"3'-1
1
4
"
(E) ELECTRICAL PANEL TO BE PROTECTED
D21
D21
AEC: EXISTING MEN'S ROOM DEMOLITION FLOOR PLAN
SCALE:
1
2
" = 1'-0"
AEC: EXISTING WOMEN'S ROOM DEMOLITION FLOOR PLAN
SCALE:
1
2
" = 1'-0"
D16 D16D16D16 D16
3'-7"14'-0"
3'-8
1
2
"
D6
D6D25
D9
SAWCUT 4" CONCRETE SLAB
TO EXPOSE U.G. DRAIN LINES
D9
SAWCUT 4" CONCRETE SLAB
TO EXPOSE U.G. DRAIN LINES
D11
4-INCH C.O.T.G. TO REMAIN
D22D11
D8D8
SCOPE OF DEMOLITION WORK:
REMOVE ALL (E) PLUMBING FIXTURES,
FLOOR DRAINS, TOILET ENCLOSURES,
WALL TILES, FLOOR TILES, LIGHT
FIXTURES, SWITCHES AND PARTITION
WALLS WHERE SHOWN. PREPARE ALL
COMPONENTS IN ORDER TO INSTALL
NEW PLUMBING LINES, SELF- PRIMING
FLOOR DRAINS, PLUMBING FIXTURES,
LIGHT FIXTURES, SWITCHES AND TOILET
PARTITIONS AT LOCATIONS SHOWN. THIS
INCLUDES EXPOSING STUD FRAMING TO
INSPECT THE EXISTING AS-BUILT
CONDITION. REPAIR AND REINFORCE
FRAMING AND ADD BLOCKING AS
NECESSARY TO ANCHOR THE NEW WALL
MOUNTED FIXTURES AND APPLIANCES.
VENTURA COUNTY
COMMUNITY
COLLEGE DISTRICT
VENTURA COLLEGE
4667 Telegraph Road
Ventura, CA 93003
AEC: GYMNASIUM
MEN & WOMEN
RESTROOM
RENOVATION
PROJECT DIRECTORY
SOILS ENGINEER / SEPTIC SYSTEM:
XXXX
CIVIL ENGINEER:
XXXX
STRUCTURAL ENGINEER:
XXXX
ELECTRICAL ENGINEER:
LUCCI & ASSOCIATES
805/389.6520
MECHANICAL ENGINEER:
A/E GROUP
805/653.1722
LANDSCAPE ARCHITECT:
XXXX
WATER SYSTEM / FIRE PROTECTION SYSTEM:
XXXXt
THIS PLAN IS BASED UPON DATA COMPILED
AND FURNISHED BY OTHERS.
BUILDING AND SAFETY - SUBMITTAL
SHEET NAME
DATE
SCALE
PROJECT
SHEET NUMBER OF SHEETS
C15 - 007
00
ROY E COLBERT
ARCHITECTURE
PLANNING
DESIGN
353 SAN JON ROAD
VENTURA, CA 93001
805 / 650 . 9590 PH
805 / 650 . 9589 FX
CALIFORNIA C12050
N.C.A.R.B.
AS SHOWN
This project has been designed by me, or
under my direct supervision.
PRELIMINARY - NOT FOR CONSTRUCTION
PLANNING - SUBMITTAL
.
ISSUED FOR CONSTRUCTION
PRELIMINARY - NOT FOR CONSTRUCTION
15-007:AEC: A-2
(E) F.C.O. @ TICKET BOOTH
D10D13
D23(E) DRINKING FOUNTAINS TO REMAIN
D23
D24
REMOVE (E) DOORS & PREP FOR (N)
D24D24
D24
D25REMOVE (E) 2x4 FRAMED WALL
D25
EXPOSE THIS (E) CHASE DURING
DEMOLITION FOR ACCESS TO
PLUMBING
D26REMOVE (E) DRINKING FOUNTAIN AT THIS
LOCATION
D26
D6D25D6D25
D27
(E) SKYLIGHTS TO REMAIN - REMOVE CEILING
TILES & PREP FOR (N) GYP. BD.
D27
D27
D27
D27
D28REMOVE/REPLACE EXHAUST FAN COVER PLATE -
WHITE
D28
D28
D14
20'-9
1
2
"
21'-3
1
2
"
19'-9"1'-1"
5'-0" I.D
.
CLE
AR
2'-6" I.D
.
CLE
AR
2'-0"
5'-0"
1'-7
1
2
"
3'-0"4"
4'-10"
1'-6"4'-5" 2'-0"
6'-0"
2'-10"
9'-4"
1'-6"
3'-6"
5'-0
1
2
"
3'-0"
3'-1"
1'-6
1
2
"
28'-10
3
4
"
6'-0"
22'-10
3
4
"
17'-1"
3'-5"
5'-3"
13'-10
3
4
"
9'-9"
1 10 12
AEC: (N) WOMEN'S ROOM FLOOR PLAN
SCALE:
1
2
" = 1'-0" SCALE:
1
2
" = 1'-0"
AEC: (N) MEN'S ROOM FLOOR PLAN
2'-1"
16'-0
1
2
"
5'-3"
1'-7
1
2
"
3'-0" 4"
2'-10"
9'-4"
1'-6" 4'-5"2'-6"2'-6"2'-6"2'-6" 2'-6"2'-6"
1'-5
3
4
"
3'-1" I.D
.
CLE
AR
2'-6" I.D
.
CLE
AR
2'-6" I.D
.
CLE
AR
2'-6" I.D
.
CLE
AR
2'-6" I.D
.
CLE
AR
2'-6" I.D
.
CLE
AR
6'-0"
5'-0"
14'-1
1
2
"
3'-0"3'-0"3'-0"3'-0" 2'-11"
3'-0" I.D
.
CLE
AR
3'-0"
3'-0"
7'-9" I.D. CLEAR
6'-6"
20'-6"
2'-6"
5'-0"
5'-1
1
2
"
KEY NOTES
(E) 8-INCH CONCRETE WALL TO REMAIN
4
2
3
1
7
6
5
36" L x 1
1
2
" DIAM. STAINLESS STEEL GRAB BAR @
33" - 36" A.F.F. (DISABLED ACCESS)
42" L x 1
1
2
" DIAM. STAINLESS STEEL GRAB BAR @
33" - 36" A.F.F. (DISABLED ACCESS)
8
9
(E) 2x8 WOOD STUD PARTITION TO REMAIN
REINFORCE AS REQ'D FOR STABILITY
10
11
12
13
14
15
16
(E) 2x4 WOOD STUD PARTITION TO REMAIN
REINFORCE AS REQ'D FOR STABILITY
(E) 2x6 WOOD STUD PARTITION TO REMAIN
REINFORCE AS REQ'D FOR STABILITY
INSTALL (N) ZURN SELF-PRIMING FLOOR DRAIN
VERIFY MODEL WITH VENTURA COLLEGE M&O
(N) 2x8 WOOD STUD PARTITION
(N) 2x4 WOOD STUD PARTITION
7
PORCELAIN WALL TILE o/ THINSET MORTAR o/
1
2
"
DUROCK BOARD TO 8-FT - TYP. ALL WALLS
8
8
8
8
7
1'-3"
2'-7"
2'-7"
2'-7"
2'-7"
2'-7"
1'-3"
1'-5
1
2
"
3'-0"3'-0"3'-0"3'-0"
1'-6"
3'-6"
(N) 2x6 WOOD STUD PARTITION
8
8
8
8
6
5
3
8
17
18
19
20
21
22
15
16
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
CERAMIC TILE FLOORING o/ THINSET o/ CUSTOM
"REDGARD" MEMBRANE
KOHLER KINGSTON TOILET #K-4325 (WHITE) w/
#K-4731-C SEAT 1.6 GPF - SEE PLUMBING PLANS
24
11
11
11
11
11
24
1111111111
111111
VERIFY SEAT
@ 17"-19" A.F.F.
VERIFY SEAT
@ 17"-19" A.F.F.
10
10
10
10
10
2'-8" DR. PNL.
2'-8" DR. PNL.
2'-4" DR. PNL.
2'-4" DR. PNL.
2'-4
" D
R. P
NL
.
2'-4
" D
R. P
NL
.
2'-4
" D
R. P
NL
.
2'-4
" D
R. P
NL
.
2'-4
" D
R. P
NL
.
2'-4
" D
R. P
NL
.
2'-4
" D
R. P
NL
.
2'-4
" D
R. P
NL
.
2'-4" DR. PNL.
2'-4" DR. PNL.
8
6
8
8
8
7
2 4 4
7
2 7
8
CHICAGO FAUCET #802-V 317ABCPD
13131313
13131313131313
KOHLER DEXTER URINAL #K-0-5015-ET (WHITE) 0.5
GPF - SEE PLUMBING PLANS
15
14
3'-0" DR. PNL.
1'-0"
1'-0"
15
5'-3"
4'-0"
8 8
8
8
EX
IS
TIN
G M
EC
HA
NIC
AL
C
HA
SE
T
O R
EM
AIN
EXTEND (E) MECHANICAL CHASE AS REQUIRED
FOR (N) PLUMBING FIXTURES/STALLS
17
6
8
8
ASI #9012 BABY CHANGING STATION - SURFACE
MOUNT - NOTE MEN'S ROOM CONDITION
18
18
FLORIANA "HEATHER" 12" x 24"
(LOWE'S #0486888) PORCELAIN
2'-6" 2'-6" 2'-6"
7'-6"
EX
IS
TIN
G M
EC
HA
NIC
AL
C
HA
SE
T
O R
EM
AIN
7
8
5
12
12
12
12
12
12
AMBULATORY
ACCESSIBLE
WHEELCHAIR
ACCESSIBLE
15
AMBULATORY
ACCESSIBLE
WHEELCHAIR
ACCESSIBLE
VENTURA COUNTY
COMMUNITY
COLLEGE DISTRICT
VENTURA COLLEGE
4667 Telegraph Road
Ventura, CA 93003
AEC: GYMNASIUM
MEN & WOMEN
RESTROOM
RENOVATION
PROJECT DIRECTORY
SOILS ENGINEER / SEPTIC SYSTEM:
XXXX
CIVIL ENGINEER:
XXXX
STRUCTURAL ENGINEER:
XXXX
ELECTRICAL ENGINEER:
LUCCI & ASSOCIATES
805/389.6520
MECHANICAL ENGINEER:
A/E GROUP
805/653.1722
LANDSCAPE ARCHITECT:
XXXX
WATER SYSTEM / FIRE PROTECTION SYSTEM:
XXXXt
THIS PLAN IS BASED UPON DATA COMPILED
AND FURNISHED BY OTHERS.
BUILDING AND SAFETY - SUBMITTAL
SHEET NAME
DATE
SCALE
PROJECT
SHEET NUMBER OF SHEETS
C15 - 007
00
ROY E COLBERT
ARCHITECTURE
PLANNING
DESIGN
353 SAN JON ROAD
VENTURA, CA 93001
805 / 650 . 9590 PH
805 / 650 . 9589 FX
CALIFORNIA C12050
N.C.A.R.B.
AS SHOWN
This project has been designed by me, or
under my direct supervision.
PRELIMINARY - NOT FOR CONSTRUCTION
PLANNING - SUBMITTAL
.
ISSUED FOR CONSTRUCTION
GRAB BAR / PARTITION / CHANGING STATION
SHALL BE MOUNTED INTO CONCRETE WALL WITH
1
4
" EPOXY ANCHOR INTO CONCRETE WALL
1919
1'-6
1
2
"
3'-0"
3'-0"
3'-1
1
2
"
VERIFY SEAT
@ 17"-19" A.F.F.
3'-0" I.D
.
CLE
AR
7
1
2
"
21
7
1
2
"
5'-0
1
2
"
20
17
4
4
4
4
8
KOHLER TAHOE LAVATORY #K-2890-4U (WHITE)
UNDERCOUNTER MOUNT - SEE PLUMBING PLANS
14 14 14 14
1414
1414141414
19
15
15
20
20
8"
8"
6"
8" 8" 8" 8" 8"
3'-0"
8"
3'-0"
6"
2'-11"
8"
5'-0" I.D
.
CLE
AR
3'-6"
GEORGIA PACIFIC #56508 SOFPULL TOILET TISSUE
DISPENSER - INSTALL BY CONTRACTOR
22
7
1
2
"
7
1
2
"
22
FIN.
℄
℄℄
℄℄
℄℄
℄℄
℄℄
℄℄℄
FIN.
FIN.
FIN
.
FIN
.
FIN
.
FIN
.
℄℄℄℄℄℄
BOBRICK #B-270 SANITARY NAPKIN DISPOSAL AT
WOMEN'S COMPARTMENTS
25 25 252525
25 25 25
25
25
25
25
℄
℄℄
3'-0
1
2
"
3'-0"
1'-6"
FIN.
℄℄
1'-6"
3'-0
1
2
"
℄
℄℄
℄
℄
FIN.
FIN.
WAXIE "CLEAN & SOFT" #850593 TOWEL DISPENSER
SURFACE MOUNT (SUPPLIED BY VENTURA COLLEGE)
26
EXTREME-AIR #GXT9-M ELECT. HAND DRYER; 120v
1500w / 6.5AMP o/ SEPARATE CIRCUIT
2727
2727
3'-6
1
8
"
5'-0"
3'-0" I.D
.
CLE
AR
F.O.S.
F.O.S.
F.O.S.
F.O.C.W.
F.O.C.W.
F.O.C.W.
F.O.S.
F.O.S.
F.O
.S
.
F.O
.C
.W
.
F.O
.S
.
FIN
.
F.O
.S
.
F.O
.S
.
F.O
.S
.
F.O
.C
.W
.
F.O
.S
.
F.O
.S
.
F.O
.S
.
COUNTER TOP:
3
4
" GRANITE "LUNA PEARL", FROM
PACIFIC STONEWORKS, 31 PEKING ST., VENTURA,
CA 93001 [805/648.4098] o/
3
4
" PLYWOOD
28
2828
28
8"
8"
GEORGIA PACIFIC #57710 SAF-T-GARD TOILET SEAT
COVER DISPENSER - INSTALL BY CONTRACTOR
23
23
23
20
22
20 20 20 20
20
20
20 20
23
23
23
23
23
23 23
23
23
23232323
RESTROOM FINISH SCHEDULE
WALLS:
TILE GROUT PAINT
TEC ADVANCED PERFORMANCE
#940 "ANTIQUE WHITE"
FLOORS
DUNN-EDWARDS: DEW 382 FADED GRAY
@ WALLS ABOVE TILE & CEILINGS
AMERICAN OLEAN "SHADOW BAY"
SEA GRASS SH52 12"x12" PORCELAIN
ACCESSORIES
FINISH VERTICAL EDGE: SCHLUTER "SCHIENE" #10 (
3
8
")
EDGE PROFILE; STAINLESS STEEL
CUSTOM "REDGARD" WATERPROOF &
CRACK ISOLATION
TILE MEMBRANE ACCESSORIES
COVE BASE: SCHLUTER "DILEX-HKUE"
w/ #HKUR 10E AT CORNERS; STAINLESS STEEL
GROUT
TEC ADVANCED PERFORMANCE
#934 "DELOREAN GRAY"
BOBRICK #B-2888 TOILET TISSUE DISPENSER
SURFACE MOUNT
BOBRICK #B-2888 TOILET TISSUE DISPENSER
SURFACE MOUNT w/ EXPANSION ANCHOR INTO
CONCRETE WALL
METPAR "THE CORINTHIAN" #FP-500SS TOILET
COMPARTMENT PARTITIONS ROTARY BRUSH SWIRL
#
301
304
STAINLESS ST'L w/ #4 SATIN FIN.
NOTE: OUTSWING DOORS AND LATCHSETS
29
29
29
29
29 29 29 29 29
292929
29
29
29
29
29
29
29
29
29
29
11
KOHLER KINGSTON TOILET #K-4325 (WHITE) w/
#K-4731-C SEAT 1.6 GPF - SEE PLUMBING PLANS
PEMKO SADDLE ADA THRESHOLD TO BLEND (N)
FLOOR TILES FOR A SMOOTH FINISH SURFACE
3030
16"x16", 12"x12" STAINLESS STEEL WALL ACCESS
PNLS - COORDINATE WITH PLUMBER
32
(N) 3-FT WIDTH DOOR / IN-SWING / PUSH-PULL
HARDWARE / CLOSER / 1
1
2
PR STNLSS STL HINGES
32
9
9
9
9
9
9
9
9
9
9
9
9
9
INSTALL (N) DISABLED ACCESS SIGNAGE FOR
UNISEX RESTROOMS PER CBC, CHAP. 11
33
33
33
33
AEC: EVENT CENTER
MEN & WOMEN
RESTROOMS
FLOOR PLANS
LOBBY AREA - EGRESS (11B-207)
15-007:AEC: A-3
32
33
3'-0
" D
R. P
NL
.
3'-1
1
2
"
(E) DRINKING FOUNTAIN & RAILINGS TO REMAIN
36
INSTALL (N) 1
1
2
" DIAM. STAINLESS STEEL PIPE
RAILS w/ 2x BLOCK'G IN (E) WALL - 3'-0" I.D. CLEAR
35
34
35
A-5
6
P-3
1
P-3
1
A-5
5
P-3
4
P-3
4
A-5
5
A-5
5
A-5
5
P-3
3
P-3
3
P-4
3
P-3
3
P-3
3
26
A-6
1
A-6
2
A-5
1
A-5
2
A-5
2
A-5
1
A-5
1
27
SIM.
A-5
1
A-5
1
SIM.
(N) DRINKING FOUNTAIN - ELKAY #LZSG8WSSK
STAINLESS STEEL PER ADA REQ'TS
℄ ℄
NOTES:
1. THINSET MORTAR: FOR PORCELAIN TILE (WHITE)
2. SEAL ALL GROUT WITH AQUA MIX PENETRATING SEALER
3. INSTALL
1
2
" DUROCK BACKERBOARD o/ (1) - 6 MIL
POLYETHYLENE MOISTURE BARRIER
w/ 1
1
4
" SUPERIOR-BILT BACKER BOARD SCREWS
@ 8-INCH ON CENTER (TCA HANDBOOK DETAIL #EJ-171)
4. ACCESSIBLE TOILETS SHALL BE FITTED WITH
ZURN #ZER6000AV-CPM ELECTRONIC FLUSH VALVES.
ALL OTHER TOILETS SHALL BE FITTED WITH THE SLOAN
111-1.6 HET MANUAL FLUSH VALVES.
5. GEORGIA PACIFIC ITEMS #20 & #23 WILL BE SUPPLIED BY
VENTURA COLLEGE AND SHALL BE INSTALLED BY THE
CONTRACTOR.
6. WAXIE TOWEL DISPENSER #26 WILL BE SUPPLIED BY
VENTURA COLLEGE AND SHALL BE INSTALLED BY THE
CONTRACTOR.
7. FURR CEILING DOWN AS REQUIRED TO SEAL OVERHEAD
PLUMBING LINES AND HVAC DUCTS PER DTL 15/A-7.
8. REINFORCE THE REPLACEMENT CONCRETE SLAB WITH
#4 BARS, GRADE 60, AT 24" O.C.E.W. DOWEL THE NEW
SLAB TO THE EXISTING SLAB WITH #4 BARS AT 48" O.C.
10. REMOVE (E) CEILING TILES & INSTALL (N)
5
8
" TYPE-X GYP. BD.
USG "PURPLE BOARD" FOR WET LOCATIONS.
31
3131
31
(E) SKYLIGHTS TO REMAIN - (N)
5
8
" TYPE-X GYP.
BD. AT LIGHT-WELL SHAFT
37
37
(N) EXHAUST FAN COVER PLATE - WHITE
38
38
37
37
A-5
8
A-5
8
3'-0" I.D
.
CLE
AR
(N)
5
8
" TYPE-X (1-HR) GYP. BD. CEILING
THROUGHOUT
39
39
39
39
39
39
39
VENTURA COUNTY
COMMUNITY
COLLEGE DISTRICT
VENTURA COLLEGE
4667 Telegraph Road
Ventura, CA 93003
AEC: GYMNASIUM
MEN & WOMEN
RESTROOM
RENOVATION
PROJECT DIRECTORY
SOILS ENGINEER / SEPTIC SYSTEM:
XXXX
CIVIL ENGINEER:
XXXX
STRUCTURAL ENGINEER:
XXXX
ELECTRICAL ENGINEER:
LUCCI & ASSOCIATES
805/389.6520
MECHANICAL ENGINEER:
A/E GROUP
805/653.1722
LANDSCAPE ARCHITECT:
XXXX
WATER SYSTEM / FIRE PROTECTION SYSTEM:
XXXXt
THIS PLAN IS BASED UPON DATA COMPILED
AND FURNISHED BY OTHERS.
BUILDING AND SAFETY - SUBMITTAL
SHEET NAME
DATE
SCALE
PROJECT
SHEET NUMBER OF SHEETS
C15 - 007
00
ROY E COLBERT
ARCHITECTURE
PLANNING
DESIGN
353 SAN JON ROAD
VENTURA, CA 93001
805 / 650 . 9590 PH
805 / 650 . 9589 FX
CALIFORNIA C12050
N.C.A.R.B.
AS SHOWN
This project has been designed by me, or
under my direct supervision.
PRELIMINARY - NOT FOR CONSTRUCTION
PLANNING - SUBMITTAL
.
ISSUED FOR CONSTRUCTION
KEY NOTES
WALL TILE: FLORIANA "HEATHER" o/ THINSET
4
2
3
1
6
5
LINE OF WALL TILE
COUNTER TOP: GRANITE "LUNA PEARL" PER
PACIFIC STONEWORKS, VENTURA, CA
PAINT: DUNN-EDWARDS DEW 382 FADED GRAY
PARTITIONS: MET-PAR CORP.
(N) 2x6 WOOD STUD PARTITION
2
1
1 1
1
3
7(N) 2x4 WOOD STUD PARTITION
7
4
4
5
2'-4" 2'-4" 2'-8"
ADAPTABLE ACCESSIBLE
8'-0"
2'-10"
2'-5"
4'-5"
4'-9
1
2
"
2 2 27
7
5 5
3'-0" 2'-4" 2'-4" 2'-4" 2'-4" 2'-4"
8"6" 8"
7
6'-10"
1'-0"
1'-0"
7'-9"
ACCESSIBLE BEYOND
5'-0"
3 3 3 3 3
6
1
1
5 5
3'-4"
5'-0" 5'-0"
3'-6
1
8
"
8" 8" 8" 8" 8" 8"
4'-11"
6'-6"
5
2'-4" 2'-4"
8"8"
2'-8"
ADAPTABLE
3'-0"
8"ACCESSIBLE
18'-0"
11'-0" 4'-5"
3'-4"
SEMI-RECESSED A.D.A. RATED DISPENSER
BOBRICK - SUBMIT MFR'S TECH DATA
EXTREME-AIR #GXT9-M ELECT. HAND DRYER; 120v
1500w / 6.5AMP o/ SEPARATE CIRCUIT
8
88
88
9
14
2
3
1
1
4
1
1
33 3
2 2
3 3
2
1
1 1
1
7
6
5
7"-9"
ACCESSIBLE
4
3'-0"
17"-19"
FINISH FLOORINGFINISH FLOORING FINISH FLOORING
1'-6"
17"-19"
2'-10"
2'-5"
2'-6" 2'-6" 2'-6" 2'-6" 2'-6"2'-6"
CLEAR I.D. CLEAR I.D. CLEAR I.D. CLEAR I.D. CLEAR I.D. CLEAR I.D.
3'-0"
FINISH FLOORING FINISH FLOORINGFINISH FLOORINGFINISH FLOORING
AEC LOBBY: (N) WOMEN'S ROOM INTERIOR ELEVATIONS
SCALE:
1
4
" = 1'-0"
NORTHWESTSOUTH EAST
AEC (N) MEN'S ROOM INTERIOR ELEVATIONS
SCALE:
1
4
" = 1'-0"
NORTHWESTSOUTH EAST
1'-5"
A-5
5
P-3
4
A-5
5
P-3
1
A-5
1P-3
4
A-5
5
P-3
4
A-5
5
P-3
4
2'-6" 2'-6" 2'-6" 2'-6" 2'-6"
2'-6" 2'-6" 2'-6"
2'-0
1
8
"
1'-6"
1'-6"
1'-0"
4'-0"
2'-0"
1'-0"
5'-10"
15-007:AEC: A-4
LINE OF WALL BEYOND - EXTEND CHASE AS
MINIMUM REQUIRED FOR DUCTS & LINES
10
ACCESSIBLE
5
5
10
CLEAN-OUTS ABOVE EACH URINAL w/ 4-INCH
DIAM. STAINLESS STEEL ACCESS PANELS
11
1111
12
WAXIE "CLEAN & SOFT" #850593 TOWEL DISPENSER
SURFACE MOUNT (SUPPLIED BY VENTURA COLLEGE)
NOTES:
1. FURR DOWN THE FINISH CEILING AS MAY BE
REQUIRED TO ACCOUNT FOR OVERHEAD
PLUMBING LINES AND HVAC DUCTS PER 15/A-7.
2. ALL VERTICAL INSTALLATION DIMENSIONS ARE
INTENDED TO COMPLY WITH ALL RELEVANT
ACCESSIBILITY REQUIREMENTS.
3. CONFIRM THE SIZE AND LOCATIONS OF
STAINLESS STEEL ACCESS PANELS (NOTE 13)
4. CONFIRM THE OPENING (HINGED OR SCREWED)
OF ACCESS PANELS.
1
2
1316"x16", 12"x12" STAINLESS STEEL WALL ACCESS
PNLS - COORDINATE WITH PLUMBER
13
13
13
13
13
AT WALL
BEYOND
13
AT WALL
BEYOND
FIN
. T
ILE
℄
℄℄℄℄℄℄
℄
9
℄ ℄ ℄ ℄
13 13
13 13
13
AT WALL
BEYOND
13
13
FIXED PANEL FIXED PANEL FIXED PANEL FIXED PANEL
8'-0"
2'-10"
2'-5"
2'-0" 1'-2"
2'-0"1'-2"
14
5
13
13
13
AT WALL
BEYOND
WAXIE "CLEAN & SOFT" #850593 TOWEL DISPENSER
SURFACE MOUNT (SUPPLIED BY VENTURA COLLEGE)
1
1
14
1
1
15
RICHARDS-WILCOX #105 SERIES SLIDING DOOR
ASS'Y w STAY ROLLER & H.D. OFFSET HASP
16
AEC: EVENT CENTER
MEN & WOMEN
RESTROOMS
ELEVATIONS
(N)
5
8
" TYPE-X (1-HR) GYP. BD. CEILING
THROUGHOUT
16161616
16 16 16 16
VENTURA COUNTY
COMMUNITY
COLLEGE DISTRICT
VENTURA COLLEGE
4667 Telegraph Road
Ventura, CA 93003
AEC GYMNASIUM
MEN & WOMEN
RESTROOM
RENOVATION
PROJECT DIRECTORY
SOILS ENGINEER / SEPTIC SYSTEM:
XXXX
CIVIL ENGINEER:
XXXX
STRUCTURAL ENGINEER:
XXXX
ELECTRICAL ENGINEER:
LUCCI & ASSOCIATES
805/389.6520
MECHANICAL ENGINEER:
A/E GROUP
805/653.1722
LANDSCAPE ARCHITECT:
XXXX
WATER SYSTEM / FIRE PROTECTION SYSTEM:
XXXXt
THIS PLAN IS BASED UPON DATA COMPILED
AND FURNISHED BY OTHERS.
BUILDING AND SAFETY - SUBMITTAL
SHEET NAME
DATE
SCALE
PROJECT
SHEET NUMBER OF SHEETS
C15 - 007
00
ROY E COLBERT
ARCHITECTURE
PLANNING
DESIGN
353 SAN JON ROAD
VENTURA, CA 93001
805 / 650 . 9590 PH
805 / 650 . 9589 FX
CALIFORNIA C12050
N.C.A.R.B.
AS SHOWN
This project has been designed by me, or
under my direct supervision.
PRELIMINARY - NOT FOR CONSTRUCTION
PLANNING - SUBMITTAL
.
ISSUED FOR CONSTRUCTION
PRELIMINARY - NOT FOR CONSTRUCTION
OUTSIDE CORNER DTL - TYPICAL
SCALE: HALF SCALE
5
2x FRAMING
PORCELAIN WALL TILE: FLORIANA "HEATHER" 12" x 24"
GROUT: TEC ADVANCED PERFORMANCE #940
ANTIQUE WHITE
THINSET MORTAR: WHITE, FOR PORCELAIN
1
2
" DUROCK BACKER BOARD TO CEILING
OVER 6 MIL POLYETHYLENE MOISTURE BARRIER
WITH 1
1
4
" SUPERIOR-BIT BACKER BOARD SCREWS
AT 8" O.C. (SEE T.C.A. DETAIL #EJ-171)
SCHLUTER "SCHIENE" 10E 316L
VERTICAL EDGE TRIM
PORCELAIN WALL TILE: FLORIANA "HEATHER" 12" x 24"
GROUT: TEC ADVANCED PERFORMANCE #940
ANTIQUE WHITE
SCHLUTER "SCHIENE" 10E 316L
VERTICAL EDGE TRIM
PORCELAIN WALL TILE: FLORIANA "HEATHER" 12" x 24"
GROUT: TEC ADVANCED PERFORMANCE #940
ANTIQUE WHITE
15-007:AEC_C: A-7
TYPICAL FOR ALL
OUT CORNER CONDITIONS
PIPE RAIL DETAIL AT DRINKING FOUNTAINS
SCALE: 1" = 1'-0"
6
1'-6"
2'-9"
3
1
2
" O.D. RADIUS +/-
BUTT WELD
GRIND SMOOTH
TYP. EA. END
1
1
2
" DIAM. STAINLESS
STEEL PIPE RAILING
GRIND SMOOTH ALL
WELDS
4-HOLE FLANGE
ANCHOR INTO BLOCKING
TYPICAL
FLANGE w/
SET SCREW
SET POST IN CORE DRILLED HOLE
BTTM OF SLEEVE CLOSED w/ PLATE
SLEEVE I.D. = PIPE O.D. +
1
16
"
SET POST & SLEEVE IN GROUT(E) CONC. FL'R SLAB
6"
4"
REPAIR ALL ADJACENT WALL
AND FLOOR SURFACES TO MATCH
THE EXISTING SURFACES
4-HOLE FLANGE
ANCHOR INTO BLOCKING
TYPICAL
(N) TILE FIN.
2x8 BLOCK'G
2x8 BLOCK'G
SECURE BLOCK TO STUDS
w/ (2)-#9x1
1
2
" SDS SCREWS
@ EACH END
AEC: EVENT CENTER
C: GYMNASIUM
RESTROOM
SELECTED DETAILS
WALL FRAMING
ADD 2x FRAMING
FOR ADD'L SUPPORT
WALL X-SECT - TYPICAL
SCALE: 1" = 1'-0"
1
WALL X-SECT - TYPICAL
SCALE: 1" = 1'-0"
2
3x SILL P.T.D.F.
w/ HILTI SHOT PIN
@ 32" O.C.
2x STUD FRAMING
@ 16" O.C.
1
2
" DUROCK SHEATHING
FLORIANA "HEATHER"
WALL TILE
CONC. FLOOR SLAB
PAINT - ENAMEL
SEMI GLOSS FINISH
(E) 2x12 JOISTS
PERPENDICULAR
SIMPSON STCT
@ EACH JOIST
3x SILL P.T.D.F.
w/ HILTI SHOT PIN
@ 32" O.C.
2x STUD FRAMING
@ 16" O.C.
1
2
" DUROCK SHEATHING
FLORIANA "HEATHER"
WALL TILE
CONC. FLOOR SLAB
PAINT - ENAMEL
SEMI GLOSS FINISH
(E) 2x12 JOISTS
PARALLEL
SIMPSON STCT
@ EACH JOIST
2x12 BLOCKING @ 48" O.C.
PARALLEL ROOF FRAMING PERPENDICULAR ROOF FRAMING
8'-0"
8'-0"
WALL BASE DETAIL
SCALE: 3" = 1'-0"
4
SCHLUTER 10E 316L
COVE BASE TRIM - TYP.
3x SILL P.T.D.F.
w/ HILTI SHOT PIN
@ 32" O.C.
2x STUD FRAMING
@ 16" O.C.
1
2
" DUROCK SHEATHING
FLORIANA "HEATHER"
WALL TILE
A-7
4
A-7
4
3x SILL P.T.D.F.
w/ HILTI SHOT PIN
@ 32" O.C.
P.T.D.F. WOLMANIZED
2x STUD FRAMING
@ 16" O.C.
1
2
" DUROCK SHEATHING
FLORIANA "HEATHER"
WALL TILE
CONC. FLOOR SLAB
PAINT - ENAMEL
SEMI GLOSS FINISH
(E) 2x12 JOISTS
PERPENDICULAR
SIMPSON STCT
@ EACH JOIST
(E) CONCRETE WALL
PARALLEL ROOF FRAMING
AT CONCRETE WALL
8'-0"
A-7
4
WALL X-SECT - TYPICAL
SCALE: 1" = 1'-0"
3
DOORS
SCALE: 1" = 1'-0"
8
AEC: TYPICAL WOOD DOORS
3'-0"
7'-0"
3'-0"
3-FT x 7-FT INTERIOR WOOD DOOR w/ MTL
FRAME & PUSH PULL OPERATION
A-7
9
JAMB DETAIL
SCALE: 3" = 1'-0"
9
HEAD DETAIL
SCALE: 3" = 1'-0"
10
12 GAUGE H.M. FRAME
STEELCRAFT F-12
1
3
4
" DOOR
PORCELAIN TILE
o/ THINSET
o/
1
2
" DUROCK
5 1/2"
2"
2"
5 1
/2
"
A-7
10
4x HEADER
PORCELAIN TILE
o/ THINSET
o/
1
2
" DUROCK
12 GAUGE H.M. FRAME
STEELCRAFT F-12
1
3
4
" DOOR
8"
2'-10"
STAINLESS STEEL KICKPLATE
AT PUSH SIDE ONLY
STAINLESS STEEL PUSH PLATE
AND PULL HANDLE
MORTISE DEADBOLT LOCK
PER VENTURA COLLEGE
REPLACEMENT CONCRETE DETAIL
SCALE: 1" = 1'-0"
7
PORCELAIN FLOOR TILE
THIN-SET MORTAR
CRACK ISOLATION
MEMBRANE
(N) SLAB (E) SLAB
4" CONCRETE
#4 DOWEL x 12" LENGTH
@ 48" O.C. SET IN EPOXY GROUT
4" 4" 4"
#4 BARS @
24" O.C.E.W.
4" CLEAN WASHED SAND
10 MIL POLYETHYLENE
MOISTURE BARRIER
1"
SUB-SOIL COMPACT TO 90%
TEST THE NEW CONCRETE FOR MOISTURE
PRIOR TO INSTALLING FLOOR TILE
9"
SOFFIT DETAIL - OPTIONAL
SCALE: 1" = 1'-0"
9
JOIST/RAFTER FRAMING
UNISTRUT #P-2000 CHANNEL
w/ SDS SCREWED TO FRAMING
@ 16" O.C.
5
8
" TYPE- X GYP. BD. FOR WET
LOCATIONS "PURPLE BOARD"
SCREWED TO UNISTRUT
2x WALL FRAMING
NOTE: THIS DETAIL SHALL APPLY WHERE A SOFFIT MAY BE REQUIRED
2'-9"
3'-1
1
2
"
3'-0"
ELKAY LZSG8WSSK
DRINKING FOUNTAIN
& BOTTLE FILLER
ADA MOUNTING
6'-0"
4'-0"
FLORIANA "HEATHER" 12" x 24"
WALL TILE o/ THINSET MORTAR
o/ DUROCK BACKER BOARD
FLORIANA "HEATHER" 2
1
2
" FACE
BULLNOSE o/ THINSET MORTAR
o/ DUROCK BACKER BOARD
2'-7
1 4
"
2'-3"
1
2
" DUROCK
ADA SADDLE DTL
SCALE: 1" = 1'-0"
8
PORCELAIN FLOOR TILE
ADA SADDLE
(E) FIN. FL'R @ LOBBY
AEC / C BLDGS:
TYPICAL DISABLED
ACCESS RESTROOM
DETAILS
VENTURA COUNTY
COMMUNITY
COLLEGE DISTRICT
VENTURA COLLEGE
4667 Telegraph Road
Ventura, CA 93003
AEC: GYMNASIUM
MEN & WOMEN
RESTROOM
RENOVATION
PROJECT DIRECTORY
SOILS ENGINEER / SEPTIC SYSTEM:
XXXX
CIVIL ENGINEER:
XXXX
STRUCTURAL ENGINEER:
XXXX
ELECTRICAL ENGINEER:
LUCCI & ASSOCIATES
805/389.6520
MECHANICAL ENGINEER:
A/E GROUP
805/653.1722
LANDSCAPE ARCHITECT:
XXXX
WATER SYSTEM / FIRE PROTECTION SYSTEM:
XXXXt
THIS PLAN IS BASED UPON DATA COMPILED
AND FURNISHED BY OTHERS.
BUILDING AND SAFETY - SUBMITTAL
SHEET NAME
DATE
SCALE
PROJECT
SHEET NUMBER OF SHEETS
C15 - 007
00
ROY E COLBERT
ARCHITECTURE
PLANNING
DESIGN
353 SAN JON ROAD
VENTURA, CA 93001
805 / 650 . 9590 PH
805 / 650 . 9589 FX
CALIFORNIA C12050
N.C.A.R.B.
AS SHOWN
This project has been designed by me, or
under my direct supervision.
PRELIMINARY - NOT FOR CONSTRUCTION
PLANNING - SUBMITTAL
.
ISSUED FOR CONSTRUCTION
15-007:AEC_C: A-8
48" MIN.
THESE ARE TYPICAL CONDITIONS AND DIMENSIONS
OF RESTROOMS. THIS INFORMATION SHALL BE USED
AS REFERENCE FOR ALL RESTROOMS.
MINIMUM NON-ABSORBENT
SURFACE
MIRROR
REQUIRED
CLEAR SPACE
30" MIN.
18" MIN.
WA
LL
A
DJA
CE
NT
48" MIN.
REQUIRED
CLEAR SPACE
30" MIN.
18" MIN.
WA
LL
A
DJA
CE
NT
TYPICAL
HAND
DRYER
AUTO-
MATIC
HAND
DRYER
PAPER
TOWELS
MIRROR
SHELF
RESTROOM ACCESSIBILITY CODE REFERENCES
ALL OPERABLE PARTS OF TOILET ROOM ACCESSORIES SHALL BE 40-INCHES HT. MAXIMUM ABOVE FINISH
FLOOR. (11B-603.5)
TOILET ROOMS SHALL COMPLY WITH CBC, SECT. 11B-603.1
2
THE CENTER LINE OF THE ACCESSIBLE TOILET SHALL BE 18 INCHES FROM THE SIDEWALL OR PARTITION.
(11B-604.2)
3
CLEARANCE AROUND AN ACCESSIBLE TOILET SHALL BE 60-INCHES MINIMUM MEASURED PERPENDICULAR
FROM THE SIDE WALL AND 56-INCHES FOR A WALL-MOUNTED TOILET MEASURED PERPENDICULAR FROM
THE REAR WALL. (11B-604.3.1 AND 11B-604.8.1)
4
3
CLEARANCE IN FRONT OF THE TOILET SHALL BE 60-INCHES MINIMUM WIDTH AND 48-INCHES DEPTH
MANEUVERING SPACE. (11B-604.3.1)
5
6
8
7
FLUSH VALVES, MANUALLY OPERATED OR AUTOMATIC, SHALL BE LOCATED ON THE OPEN SIDE OF THE
COMPARTMENT AND 44-INCH HT. MAXIMUM. (11B-604.6)
TOILET TISSUE DISPENSERS SHALL BE 7"-9" IN FRONT OF THE TOILET AS MEASURED TO THE CENTER LINE
OF THE DISPENSER, AND 19-INCHES MINIMUM ABOVE THE FINISH FLOOR. (11B-604.7)
WHEELCHAIR ACCESSIBLE TOILET COMPARTMENTS SHALL BE 60-INCHES WIDTH MINIMUM AND 56-INCHES
DEPTH FOR WALL-HUNG TOILETS, OR 59-INCHES DEPTH FOR FLOOR MOUNTED TOILETS WHEN AT LEAST
ONE SIDE WALL PROVIDES 9-INCH HEIGHT TOE SPACE UNDER. (11B-604.3.1 AND 11B-604.8.1)
9
WHEELCHAIR ACCESSIBLE TOILET COMPARTMENT DOORS SHALL BE 34-INCHES WIDTH MINIMUM CLEAR
OPENING AND BE SELF-CLOSING. (11B-604.8.1.2)
10 GRAB BARS SHALL BE 1
1
4
" - 2" DIAM. AND BE INSTALLED AT 1
1
2
" MAXIMUM FROM THE WALL IT IS MOUNTED
ON. (11B-604.8.1.5 AND 11B-609)
11
AMBULATORY ACCESSIBLE COMPARTMENTS SHALL BE 35"-37" WIDTH AND 60-INCHES DEPTH MINIMUM.
(11B-604.8.2.1)
12 URINAL SHALL BE INSTALLED WITH THE FRONT RIM 17-INCHES ABOVE FINISH FLOOR AND 13
1
2
" DEPTH
MINIMUM. (11B-605.2, 11B-605.4 AND 11B-305)
13
MANUAL LEVER FLUSH VALVES FOR TOILETS AND URINALS SHALL HAVE A OPERATING FORCE NO
GREATER THAN 5LBS. MAXIMUM, OPERATE WITH ONE HAND, AND NOT REQUIRE TIGHT GRASPING,
PINCHING, OR TWISTING OF THE WRIST. (11B-309.4)
14
LAVATORIES SHALL BE INSTALLED AT 34-INCHES HT. WITH 29-INCHES UNDER COUNTER CLEARANCE, AND
CLEAR FLOOR SPACE. (11B-606, 11B-606.4 AND 11B-305)
15
TOILET ROOM ACCESSIBILITY DOOR SYMBOLS SHALL COMPLY WITH CBC, SECT. 11B-703.7.2.6.
1. THE INTERNATIONAL SYMBOL OF ACCESSIBILITY SIGN SHALL BE DISPLAYED AT ALL
ACCESSIBLE RESTROOM FACILITIES AND AT ACCESSIBLE BUILDING ENTRANCES
UNLESS ALL ENTRANCES ARE ACCESSIBLE. INACCESSIBLE ENTRANCES SHALL
HAVE DIRECTIONAL SIGNS INDICATING THE NEAREST ACCESSIBLE ENTRANCE.
2. RECEPTACLES ON WALLS SHALL BE MOUNTED NO LESS THAN 18" ABOVE FINISH
FLOOR. EXCEPTION: HEIGHT LIMITATIONS DO NOT APPLY WHERE THE USE OF
SPECIAL EQUIPMENT DICTATES OTHERWISE, OR WHERE ELECTRICAL
RECEPTACLES ARE NOT NORMALLY INTENDED.
3. WHERE EMERGENCY WARNING SYSTEMS ARE PROVIDED, THESE SYSTEMS SHALL
INCLUDE BOTH AUDIBLE AND VISUAL ALARMS. THE VISUAL ALARMS SHALL BE
LOCATED THROUGHOUT, INCLUDING RESTROOMS, AND PLACED EITHER 80" ABOVE
FINISH FLOOR OR 6" BELOW FINISH CEILING, WHICHEVER IS LOWER.
4. DOORS TO ALL ACCESSIBLE SPACES SHALL HAVE ACCESSIBLE HARDWARE
(ie.: LEVER-OPERATED, PUSH AND U-SHAPED PULLS) INSTALLED AT 34 - 44" A.F.F.
(CBC, 11B-404.2.7)
5. FLOOR SURFACE (PER FINISH SCHEDULE) SHALL BE INSTALLED TO TO BE STABLE,
FIRM & SLIP RESISTANT. CHANGES IN LEVEL BETWEEN
1
4
" AND
1
2
" SHALL BE
BEVELED WITH A SLOPE NO GREATER THAN 1:2. CHANGES IN LEVEL GREATER THAN
1
2
" REQUIRE A RAMP. GRATINGS IN A FLOOR SURFACE SHALL HAVE SPACES NO
GREATER THAN
1
2
" WIDTH. DOORWAY THRESHOLDS AND SADDLES SHALL NOT
EXCEED
1
2
" HEIGHT.
6. GRAB BARS REQUIRED FOR ACCESSIBILITY SHALL BE 1
1
4
" - 2" DIAMETER WITH
1
1
2
" CLEAR SPACE BETWEEN THE BAR AND THE WALL. (CBC, 11B-609.2.1)
7. ACCESSIBLE WATER CLOSETS SHALL BE 17" - 19" FROM FLOOR TO TOP OF SEAT.
GRAB BARS SHALL BE 36" LENGTH LOCATED BEHIND THE WATER CLOSET AND 42"
LENGTH LOCATED ALONG THE SIDE, AND THE TOP OF THE GRAB BAR SHALL BE
BETWEEN 33" - 36" ABOVE FINISH FLOOR.
8. ACCESSIBLE URINALS SHALL BE STALL TYPE OR WALL-HUNG TYPE, EACH
WITH ELONGATED RIMS AT 17" MAXIMUM ABOVE FINISH FLOOR.
9. ACCESSIBLE LAVATORIES SHALL BE INSTALLED WITH THE RIM AT 34" MAX. ABOVE
FINISH FLOOR AND A CLEARANCE OF 29" MIN. A.F.F. TO UNDERSIDE OF THE APRON.
10. ACCESSIBLE SINKS SHALL BE INSTALLED WITH THE RIM AT 34" MAX. A.F.F. AND A
CLEARANCE OF 27" MIN. HEIGHT x 30" WIDTH x 19" DEPTH UNDER THE SINK.
11. ALL WATER AND DRAIN PIPING UNDER ACCESSIBLE LAVATORIES AND SINKS
SHALL BE INSULATED OR OTHERWISE CONFIGURED TO PROTECT AGAINST
CONTACT. THERE SHALL BE NO SHARP NOR ABRASIVE SURFACES AND EDGES
UNDER ACCESSIBLE LAVATORIES AND SINKS.
12. ACCESSIBLE LAVATORIES AND SINKS SHALL HAVE ACCESSIBLE FAUCETS AND
VALVESETS (ie.: LEVER-OPERATED, PUSH-TYPE, ELECTRONICALLY CONTROLLED).
13. WHEN MIRRORS ARE INSTALLED IN RESTROOMS ABOVE THE ACCESSIBLE
LAVATORY, IT SHALL BE INSTALLED WITH THE BOTTOM EDGE OF THE
MIRRORED SURFACE AT 40" MAX. ABOVE THE FINISHED FLOOR.
ACCESSIBILITY GENERAL NOTES
13
1
2
"
11B-605.2
40" MAX.
PER MANUF.
2'-6" CLR
2'0" MAX
2'10" M
AX
3'10" M
AX
4'0" M
AX
TOP OF THERMOSTAT,
SWITCH, OUTLET,
CONTROL
THERMOSTAT, SWITCH,
OUTLET, CONTROL
L
C
TOP
VENTURA COUNTY
COMMUNITY
COLLEGE DISTRICT
VENTURA COLLEGE
4667 Telegraph Road
Ventura, CA 93003
AEC BUILDING
PUBLIC RESTROOM
RENOVATION
PROJECT DIRECTORY
SOILS ENGINEER / SEPTIC SYSTEM:
XXXX
CIVIL ENGINEER:
XXXX
STRUCTURAL ENGINEER:
XXXX
ELECTRICAL ENGINEER:
LUCCI & ASSOCIATES
805/389.6520
MECHANICAL ENGINEER:
A/E GROUP
805/653.1722
LANDSCAPE ARCHITECT:
XXXX
WATER SYSTEM / FIRE PROTECTION SYSTEM:
XXXXt
THIS PLAN IS BASED UPON DATA COMPILED
AND FURNISHED BY OTHERS.
SHEET NAME
DATE
SCALE
PROJECT
SHEET NUMBER OF SHEETS
C15 - 007
15-806
ROY E COLBERT
ARCHITECTURE
PLANNING
DESIGN
353 SAN JON ROAD
VENTURA, CA 93001
805 / 650 . 9590 PH
805 / 650 . 9589 FX
CALIFORNIA C12050
N.C.A.R.B.
AS SHOWN
12/08/15
VENTURA COUNTY
COMMUNITY
COLLEGE DISTRICT
VENTURA COLLEGE
4667 Telegraph Road
Ventura, CA 93003
AEC BUILDING
PUBLIC RESTROOM
RENOVATION
PROJECT DIRECTORY
SOILS ENGINEER / SEPTIC SYSTEM:
XXXX
CIVIL ENGINEER:
XXXX
STRUCTURAL ENGINEER:
XXXX
ELECTRICAL ENGINEER:
LUCCI & ASSOCIATES
805/389.6520
MECHANICAL ENGINEER:
A/E GROUP
805/653.1722
LANDSCAPE ARCHITECT:
XXXX
WATER SYSTEM / FIRE PROTECTION SYSTEM:
XXXXt
THIS PLAN IS BASED UPON DATA COMPILED
AND FURNISHED BY OTHERS.
SHEET NAME
DATE
SCALE
PROJECT
SHEET NUMBER OF SHEETS
C15 - 007
15-806
ROY E COLBERT
ARCHITECTURE
PLANNING
DESIGN
353 SAN JON ROAD
VENTURA, CA 93001
805 / 650 . 9590 PH
805 / 650 . 9589 FX
CALIFORNIA C12050
N.C.A.R.B.
AS SHOWN
12/08/15
DR
AF
TE
R: C
M02 D
RA
WIN
G F
ILE
NA
ME
: 15806A
EC
E100 P
AT
HN
AM
E: G
:\15\806\E
L\S
heets\A
EC
B
UILD
IN
G D
AT
E: 14 June 2016 T
IM
E: 8:25 am
OPEN TO GYMNASIUM BELOW
FIXED SEATING
EXERCISE AREA
ENTRY LOBBY
TICKETS
CREATIVE RESOURCE CENTER
CHILD DEVELOPMENT CENTER
PHYSICAL EDUCATION ( SMALL GYM)
BOOKSTORE / CAMPUS SERVICES
ALTERNATE TEXT PRODUCTION CENTER
APPRENTICESHIP PROGRAMS
CONTINUING EDUCATION CLASSROOMS
CONTINUING EDUCATION CLASSROOMS
ATHLETIC EVENTS CENTER (LARGE GYM)
ADMINISTRATION
AGRICULTURE / CONSTRUCTION TECHNOLOGY
APP
CRC
CDC
C
BCS
ATPC
ANNEX 4
ANNEX 3
AEC
ADM
AA
AS
HW
OO
D A
VE
AUTOMOTIVE / MANUFACTURING / WELDING SHOPS
TELEGRAPH ROAD
V E N T U R A C O L L E G E
BUSINESS / CAREER / TECHNICAL EDUCATION
CAMPUS CENTER - CAFETERIA / STUDENT ACTIVITIES
LIBRARY / LEARNING RESOURCE CENTER
INST. FOR COMMUNITY AND PROFESSIONAL DEVELOPMENT
HEATLTH / SCIENCE CLASSROOMS
HEAD HOUSEHH
LRC
CLASSROOMS
CLASSROOMS
K
J
ICPD
HSC
GUTHRIE HALL
EOPS
BUSINESS / ESL
CTE
CSA
GH
EOPS
DP
STUDIO ARTS BUILDINGSAB
T
SSC
SHC
S & R
SCI
BUSINESS / COMPUTER LABS
STUDENT SERVICES CENTER
STUDENT HEALTH / PSYCHOLOGICAL SERVICES
SCIENCES / MATHEMATICS
SHIPPING / RECEIVING
PROJECT
MAC
M & O
NMG
S
PAC
MAINTENCE / OPERATIONS
PERFORMING ARTS CENTER
MEDIA ARTS CENTER
NEW MEDIA GALLERY
BUSINESSU
VENTURA COLLEGE SPORTSPLEX
LECTURE HALLS
VCS
UV
RELOCATABLE PERFORMING ARTS ( NEAR PAC)
RELOCATABLE NURSING SKILLS LAB (NEAR LRC / SSC / MAC)
RELOCATABLE CLASSROOMS (NEAR LRC / SSC / MAC)
RELOCATABLE CLASSROOMS (NEAR BASE BALL FIELD)
MULTI-MEDIA / GRAPHICS
TR 17 - 22
TR 16
TR 12 - 15
TR 5 - 8
TR 4
TR 5-6
TR 7-8
TR 19-20
TR 22
TR 17-18
LOMA VISTA ROAD
DA
Y R
OA
D
ANNEX 3
ANNEX 4
SCI
HSC
APP
SAB
CDC
VCS
ADM
CSA
T
SCI
J
CTE
K
U
UV
GH
TR 4
AEC
C
EOPS
BCS
SSC
LRC
S
H
C
CRC
NMG
MAC
PAC
DP
WRIGHT
LIBRARY
SCI
HSC
HSC
HH
EL CAMINO
HIGH SCHOOL
CAPS
ICPD
S
AA
S & R
M & O
ATPC
VENTURA COUNTY
COMMUNITY
COLLEGE DISTRICT
VENTURA COLLEGE
4667 Telegraph Road
Ventura, CA 93003
AEC BUILDING
PUBLIC RESTROOM
RENOVATION
PROJECT DIRECTORY
SOILS ENGINEER / SEPTIC SYSTEM:
XXXX
CIVIL ENGINEER:
XXXX
STRUCTURAL ENGINEER:
XXXX
ELECTRICAL ENGINEER:
LUCCI & ASSOCIATES
805/389.6520
MECHANICAL ENGINEER:
A/E GROUP
805/653.1722
LANDSCAPE ARCHITECT:
XXXX
WATER SYSTEM / FIRE PROTECTION SYSTEM:
XXXXt
THIS PLAN IS BASED UPON DATA COMPILED
AND FURNISHED BY OTHERS.
SHEET NAME
DATE
SCALE
PROJECT
SHEET NUMBER OF SHEETS
C15 - 007
15-806
ROY E COLBERT
ARCHITECTURE
PLANNING
DESIGN
353 SAN JON ROAD
VENTURA, CA 93001
805 / 650 . 9590 PH
805 / 650 . 9589 FX
CALIFORNIA C12050
N.C.A.R.B.
AS SHOWN
12/08/15
1UPPER LEVEL FLOOR PLAN
2SITE PLAN
VENTURA COUNTY
COMMUNITY
COLLEGE DISTRICT
VENTURA COLLEGE
4667 Telegraph Road
Ventura, CA 93003
AEC BUILDING
PUBLIC RESTROOM
RENOVATION
PROJECT DIRECTORY
SOILS ENGINEER / SEPTIC SYSTEM:
XXXX
CIVIL ENGINEER:
XXXX
STRUCTURAL ENGINEER:
XXXX
ELECTRICAL ENGINEER:
LUCCI & ASSOCIATES
805/389.6520
MECHANICAL ENGINEER:
A/E GROUP
805/653.1722
LANDSCAPE ARCHITECT:
XXXX
WATER SYSTEM / FIRE PROTECTION SYSTEM:
XXXXt
THIS PLAN IS BASED UPON DATA COMPILED
AND FURNISHED BY OTHERS.
SHEET NAME
DATE
SCALE
PROJECT
SHEET NUMBER OF SHEETS
C15 - 007
15-806
ROY E COLBERT
ARCHITECTURE
PLANNING
DESIGN
353 SAN JON ROAD
VENTURA, CA 93001
805 / 650 . 9590 PH
805 / 650 . 9589 FX
CALIFORNIA C12050
N.C.A.R.B.
AS SHOWN
12/08/15
DR
AF
TE
R: C
M02 D
RA
WIN
G F
ILE
NA
ME
: 15806A
EC
E150 P
AT
HN
AM
E: G
:\15\806\E
L\S
heets\A
EC
B
UILD
IN
G D
AT
E: 14 June 2016 T
IM
E: 8:25 am
OPEN TO GYMNASIUM BELOW
FIXED SEATING
EXERCISE AREA
ENTRY LOBBY
TICKETS
VENTURA COUNTY
COMMUNITY
COLLEGE DISTRICT
VENTURA COLLEGE
4667 Telegraph Road
Ventura, CA 93003
AEC BUILDING
PUBLIC RESTROOM
RENOVATION
PROJECT DIRECTORY
SOILS ENGINEER / SEPTIC SYSTEM:
XXXX
CIVIL ENGINEER:
XXXX
STRUCTURAL ENGINEER:
XXXX
ELECTRICAL ENGINEER:
LUCCI & ASSOCIATES
805/389.6520
MECHANICAL ENGINEER:
A/E GROUP
805/653.1722
LANDSCAPE ARCHITECT:
XXXX
WATER SYSTEM / FIRE PROTECTION SYSTEM:
XXXXt
THIS PLAN IS BASED UPON DATA COMPILED
AND FURNISHED BY OTHERS.
SHEET NAME
DATE
SCALE
PROJECT
SHEET NUMBER OF SHEETS
C15 - 007
15-806
ROY E COLBERT
ARCHITECTURE
PLANNING
DESIGN
353 SAN JON ROAD
VENTURA, CA 93001
805 / 650 . 9590 PH
805 / 650 . 9589 FX
CALIFORNIA C12050
N.C.A.R.B.
AS SHOWN
12/08/15
VENTURA COUNTY
COMMUNITY
COLLEGE DISTRICT
VENTURA COLLEGE
4667 Telegraph Road
Ventura, CA 93003
AEC BUILDING
PUBLIC RESTROOM
RENOVATION
PROJECT DIRECTORY
SOILS ENGINEER / SEPTIC SYSTEM:
XXXX
CIVIL ENGINEER:
XXXX
STRUCTURAL ENGINEER:
XXXX
ELECTRICAL ENGINEER:
LUCCI & ASSOCIATES
805/389.6520
MECHANICAL ENGINEER:
A/E GROUP
805/653.1722
LANDSCAPE ARCHITECT:
XXXX
WATER SYSTEM / FIRE PROTECTION SYSTEM:
XXXXt
THIS PLAN IS BASED UPON DATA COMPILED
AND FURNISHED BY OTHERS.
SHEET NAME
DATE
SCALE
PROJECT
SHEET NUMBER OF SHEETS
C15 - 007
15-806
ROY E COLBERT
ARCHITECTURE
PLANNING
DESIGN
353 SAN JON ROAD
VENTURA, CA 93001
805 / 650 . 9590 PH
805 / 650 . 9589 FX
CALIFORNIA C12050
N.C.A.R.B.
AS SHOWN
12/08/15
DR
AF
TE
R: C
M02 D
RA
WIN
G F
ILE
NA
ME
: 15806A
EC
E400 P
AT
HN
AM
E: G
:\15\806\E
L\S
heets\A
EC
B
UILD
IN
G D
AT
E: 14 June 2016 T
IM
E: 8:25 am
VENTURA COUNTY
COMMUNITY
COLLEGE DISTRICT
VENTURA COLLEGE
4667 Telegraph Road
Ventura, CA 93003
AEC BUILDING
PUBLIC RESTROOM
RENOVATION
PROJECT DIRECTORY
SOILS ENGINEER / SEPTIC SYSTEM:
XXXX
CIVIL ENGINEER:
XXXX
STRUCTURAL ENGINEER:
XXXX
ELECTRICAL ENGINEER:
LUCCI & ASSOCIATES
805/389.6520
MECHANICAL ENGINEER:
A/E GROUP
805/653.1722
LANDSCAPE ARCHITECT:
XXXX
WATER SYSTEM / FIRE PROTECTION SYSTEM:
XXXXt
THIS PLAN IS BASED UPON DATA COMPILED
AND FURNISHED BY OTHERS.
SHEET NAME
DATE
SCALE
PROJECT
SHEET NUMBER OF SHEETS
C15 - 007
15-806
ROY E COLBERT
ARCHITECTURE
PLANNING
DESIGN
353 SAN JON ROAD
VENTURA, CA 93001
805 / 650 . 9590 PH
805 / 650 . 9589 FX
CALIFORNIA C12050
N.C.A.R.B.
AS SHOWN
12/08/15
VENTURA COUNTY
COMMUNITY
COLLEGE DISTRICT
VENTURA COLLEGE
4667 Telegraph Road
Ventura, CA 93003
AEC BUILDING
PUBLIC RESTROOM
RENOVATION
PROJECT DIRECTORY
SOILS ENGINEER / SEPTIC SYSTEM:
XXXX
CIVIL ENGINEER:
XXXX
STRUCTURAL ENGINEER:
XXXX
ELECTRICAL ENGINEER:
LUCCI & ASSOCIATES
805/389.6520
MECHANICAL ENGINEER:
A/E GROUP
805/653.1722
LANDSCAPE ARCHITECT:
XXXX
WATER SYSTEM / FIRE PROTECTION SYSTEM:
XXXXt
THIS PLAN IS BASED UPON DATA COMPILED
AND FURNISHED BY OTHERS.
SHEET NAME
DATE
SCALE
PROJECT
SHEET NUMBER OF SHEETS
C15 - 007
15-806
ROY E COLBERT
ARCHITECTURE
PLANNING
DESIGN
353 SAN JON ROAD
VENTURA, CA 93001
805 / 650 . 9590 PH
805 / 650 . 9589 FX
CALIFORNIA C12050
N.C.A.R.B.
AS SHOWN
12/08/15
DR
AF
TE
R: C
M02 D
RA
WIN
G F
ILE
NA
ME
: 15806A
EC
E401 P
AT
HN
AM
E: G
:\15\806\E
L\S
heets\A
EC
B
UILD
IN
G D
AT
E: 14 June 2016 T
IM
E: 8:25 am
OPEN TO GYMNASIUM BELOW
FIXED SEATING
EXERCISE AREA
ENTRY LOBBY
TICKETS
VENTURA COUNTY
COMMUNITY
COLLEGE DISTRICT
VENTURA COLLEGE
4667 Telegraph Road
Ventura, CA 93003
AEC GYMNASIUM
MEN & WOMEN
RESTROOM
RENOVATION
PROJECT DIRECTORY
SOILS ENGINEER / SEPTIC SYSTEM:
XXXX
CIVIL ENGINEER:
XXXX
STRUCTURAL ENGINEER:
XXXX
ELECTRICAL ENGINEER:
LUCCI & ASSOCIATES
805/389.6520
MECHANICAL ENGINEER:
A/E GROUP
805/653.1722
LANDSCAPE ARCHITECT:
XXXX
WATER SYSTEM / FIRE PROTECTION SYSTEM:
XXXXt
THIS PLAN IS BASED UPON DATA COMPILED
AND FURNISHED BY OTHERS.
BUILDING AND SAFETY - SUBMITTAL
SHEET NAME
DATE
SCALE
PROJECT
SHEET NUMBER OF SHEETS
C15 - 007
00
ROY E COLBERT
ARCHITECTURE
PLANNING
DESIGN
353 SAN JON ROAD
VENTURA, CA 93001
805 / 650 . 9590 PH
805 / 650 . 9589 FX
CALIFORNIA C12050
N.C.A.R.B.
AS SHOWN
This project has been designed by me, or
under my direct supervision.
PRELIMINARY - NOT FOR CONSTRUCTION
PLANNING - SUBMITTAL
.
ISSUED FOR CONSTRUCTION
15-007:AEC: P-1
1. THE SCOPE OF WORK COVERED BY THESE PLUMBING DRAWINGS SHALL INCLUDE ALL LABOR, PLUMBING FIXTURES,
FITTINGS, EQUIPMENT, PRODUCTS, ACCESSORIES AND ALL ASSOCIATED MATERIALS NECESSARY FOR AND REASONABLY
INCIDENTAL TO THE PROPER INSTALLATION OF THE ENTIRE PLUMBING WORK SHOWN ON THE ARCHITECTURAL AND
PLUMBING DRAWINGS, INCLUDING THE NOTES AND SPECIFICATIONS. THE SCOPE SHALL FURTHER INCLUDE THE REMOVAL
OF ALL ITEMS SHOWN AND NOTED ON THE ARCHITECTURAL AND PLUMBING PLANS.
2. THE CONTRACTOR SHALL VERIFY THE EXISTING CONDITIONS PRIOR TO THE START OF WORK.
3. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT OR OWNER OF DISCREPANCIES AND UNFORESEEN CONDITIONS.
4. THE CONTRACTOR SHALL VERIFY ALL EXISTING UTILITIES WITH RESPECT TO ELEVATION, SIZE, LOCATION, MATERIAL,
METER (IF APPLICABLE) AND POINTS-OF-CONNECTION.
5. THE CONTRACTOR SHALL BE FULLY RESPONSIBLE TO VERIFY THE DISINFECTING OF ALL AFFECTED WATER LINES
WITHIN THE SCOPE OF THE PROJECT (CPC; SECT 609.9).
6. UNLESS OTHERWISE INDICATED THE CONTRACTOR SHALL BE THE RESPONSIBLE AGENT TO OBTAIN AND PAY FOR
ALL PERMITS, FEES, CONNECTION CHARGES, AND TEMPORARY SERVICE CHARGES WHERE APPLICABLE.
7. ALL MATERIALS AND METHODS OF INSTALLATION SHALL COMPLY WITH THE CALIFORNIA PLUMBING CODE, 2013 ED.,
AND ANY OTHER STATE AND LOCAL ORDINANCES.
8. THE CONTRACTOR SHALL FULLY COORDINATE THIS WORK INCLUDING ANY FIELD DETAILS WITH OTHER AFFECTED
TRADES TO AVOID ALL INTERFERENCES, TO MAINTAIN ALL REQUISITE CLEARANCES, AND TO AVOID UNNECESSARY DELAYS
9. THE CONTRACTOR AT PREPARE AND PAY FOR 5 COPIES OF THE MANUFACTURER'S TECHNICAL BROCHURES, INSTALLATION
DRAWINGS, SPECIFICATIONS, CUT SHEETS AND OTHER INFORMATION TO COMPLETELY VERIFY THE PLUMBING FIXTURES,
ACCESSORIES, EQUIPMENT, PRODUCTS, MATERIALS AND ASSOCIATED ITEMS. THIS INFORMATION SHALL BE ASSEMBLED
IN BINDER FORMAT (BOOK FORM) AND SUBMITTED TO THE ARCHITECT AND OWNER FOR APPROVAL PRIOR TO INSTALLATION.
10. THE CONTRACTOR SHALL VERIFY THE INSTALLATION OF TOILETS, LAVATORIES, URINALS, AND DRINKING FOUNTAIN
PLUMBING FIXTURES AND ALL RESTROOM ACCESSORIES COMPLY WITH ALL DISABILITY ACCESS REQUIREMENTS
PER CBC; CHAPTER 11B AND THE AMERICANS FOR DISABILITY ACT.
11. THE CONTRACTOR SHALL VERIFY THE DIMENSIONED LOCATION OF ALL PLUMBING FIXTURES PRIOR TO THE START OF WORK.
THE EXACT LOCATION OF THE PLUMBING FIXTURES IS SHOWN ON THE ARCHITECTURAL DRAWINGS.
12. THE CONTRACTOR SHALL PAY ALL COSTS OF DESIGN AND INSTALLATION FOR CHANGES RESULTING FROM THE
SUBSTITUTION OF ALTERNATE PLUMBING FIXTURES, ACCESSORIES, AND ANY OTHER PRODUCTS NOT NOTED.
ACCEPTANCE OF ALTERNATE PLUMBING FIXTURES, ACCESSORIES, AND OTHER PRODUCTS DOES NOT CHANGE THIS
RESPONSIBILITY OR REQUIREMENT.
13. THE DRAWINGS ON THE PLUMBING PLAN SHOW THE PIPES AND LINE DIAGRAMMATICALLY (SCHEMATICALLY).
THE CONTRACTOR SHALL ALLOW FOR MINOR RE-ROUTING AS MAY BE REQUIRED AS INCLUDED IN THE SCOPE OF THIS WORK.
14. THE CONTRACTOR SHALL VARY THE RUN OF PLUMBING LINES AND PIPES, AND INSTALL OFFSETS DURING THE PROGRESS
OF THE INSTALLATION AS MAY BE REQUIRED TO AVOID STRUCTURAL, HVAC, ELECTRICAL SERVICE, AND ANY OTHER
CONFLICTS WITH THIS WORK.
15. ALL BUILDING WASTE DRAIN LINES SHALL SLOPE
1
4
" PER FOOT MINIMUM.
16. CLEANOUTS SHALL BE READILY ACCESSIBLE, AND SHALL BE INSTALLED WITH ADEQUATE SPACE CLEARANCE FOR
EFFECTIVE USE. CLEANOUTS SHALL NOT BE LOCATED IN HIGH TRAFFIC AREAS OR WORK STATION AREAS. PROVIDE
CLEANOUTS WITH 135 DEGREES OF TURN AND LOCATE AT 100-FT INTERVALS MAXIMUM.
17. PROVIDE AUTOMATIC TRAP PRIMERS FOR ALL FLOOR DRAINS AND INFREQUENTLY USED PLUMBING RECEPTACLES.
18. ANY VENT PIPES THROUGH THE ROOF SHALL BE LOCATED A MINIMUM OF 10'-0" CLEARANCE FROM ANY HVAC AIR INTAKES,
WINDOWS, VENTS AND OPENINGS INTO THE BUILDING. TIE THE VENT PIPES TOGETHER TO CREATE A MINIMUM NUMBER
OF ROOF PENETRATIONS.
19. THE CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR WATERPROOF SEALING ALL ROOF PENETRATIONS INTO THE BUILDING.
THE CONTRACTOR SHALL COORDINATE THIS WATERPROOF SEALING THE ROOFING CONTRACTOR OR GENERAL CONTRACTOR.
20. ALL HOT WATER PIPING SHALL BE INSULATED WITH ONE-INCH MINIMUM FIBERGLASS INSULATION WITH ASSOCIATED JACKETING
AND "ZESTOON" FITTINGS, OR APPROVED EQUAL.
21. ROUGH-IN ALL WASTE LINES AND SUPPLY LINES TO ALL FIXTURES AND SPECIAL EQUIPMENT, AND MAKE ALL FINAL
CONNECTION HOOK-UPS ACCORDING TO THE MANUFACTURER'S INSTALLATION DRAWINGS AND REQUIREMENTS.
22. PIPING AND LINES SHALL NOT PASS THROUGH ANY FOUNDATION FOOTINGS UNLESS OTHERWISE SHOWN AND NOTED
ON THE PLANS. REFER TO THE ARCHITECTURAL AND STRUCTURAL PLANS.
23. SEAL ALL PIPING LINES THAT MAY PASS THROUGH ANY FIRE-RATED WALL OR CEILING ASSEMBLY WITH AN ICC APPROVED
FIRE STOP MATERIAL.
24. SUSPENDED PIPING LINES SHALL BE INSTALLED WITH ADJUSTABLE "J" HANGERS AND THREADED RODS, AND SHALL BE
DOUBLE NUTTED. HANGERS AND SUPPORTS SHALL BE SIZED TO FULLY SUPPORT THE FULL WEIGHT OF EACH PIPE,
THE WEIGHT OF THE FLUID AND THE WEIGHT OF THE INSULATION. PROVIDE 12-INCH LENGTH 24 GAUGE SHEET METAL
SLEEVE AT INSULATED PIPES WHERE SUPPORTED BY HANGERS.
25. EACH HANGER OR CLAMP SHALL BE INSTALLED WITH ISOLATION MATERIAL HAVING LIGHT GAUGE STEEL BAND BACKING
IN ORDER TO ISOLATE ELECTROLYSIS AND SOUND VIBRATION. THIS ISOLATION MAY NOT BE REQUIRED FOR SOIL, WASTE,
VENT AND FUEL GAS PIPE LINES.
26. ISOLATE ALL PIPING LINES FROM STRUCTURAL COMPONENTS WITH FELT PADS OR TRISOLATORS.
27. ALL INSULATED PIPING LINES SHALL HAVE A SADDLE INSTALLED AT EACH HANGER OR SUPPORT.
THESE SADDLE ASSEMBLIES SHALL BE SIZED FOR THE RESPECTIVE PIPE DIAMETERS AND FOR INSULATION THICKNESS.
28. SAW-CUTTING OF CONCRETE FLOORS AND WALLS, AND CUTTING OF OTHER STRUCTURAL COMPONENTS SHALL BE SUBJECT
TO APPROVAL BY THE ARCHITECT AND THE OWNER PRIOR TO THE START OF THIS WORK.
29. ALL SUPPLY LINES SHALL BE EQUIPPED WITH QUARTER TURN BALL VALVES AT THEIR RESPECTIVE TERMINATION.
30. INSTALL DI-ELECTRIC UNIONS AT ANY PLUMBING CONNECTION OF DISSIMILAR METALS.
31. ALL PRESSURIZED WATER LINE PIPING BELOW GRADE SHALL BE INSTALLED WITH 2'-6" DEPTH MINIMUM COVER BELOW GRADE.
32. INSTALL SHUT-OFF VALVES AT THE TERMINATION OF ALL WATER AND FUEL GAS ROUGH-IN LINES PRIOR TO CONNECTING
FINAL HOOK-UPS TO PLUMBING FIXTURES AND EQUIPMENT.
33. ALL BURIED BLACK STEEL PIPE SHALL BE FACTORY WRAPPED WITH PROTECTIVE CHLORIDE OR POLYETHYLENE TAPE;
SCOTHCHWRAP #51, OR EQUAL.
34. PROVIDE AND INSTALL WATER HAMMER ARRESTORS FOR ALL QUICK ACTING VALVES, AND AT THE END OF LONG WATER
PIPING RUNS.
35. MAXIMUM WATER TEMPERATURE SHALL BE LIMITED TO 110 DEGREE FAHRENHEIT FOR ALL PUBLIC LAVATORIES.
36. PURGE ALL WATER AND GAS LINES PRIOR TO FINAL INSPECTION.
37. TEST ALL WATER LINE SYSTEMS AT A HYDROSTATIC PRESSURE OF 150 PSIG MINIMUM WITH A 5 PSIG PERMISSIBLE
DROP AFTER FOUR (4) HOURS DURATION.
38. FILL AND TEST THE ENTIRE WASTE DRAIN AND VENT ASSEMBLY WITH WATER TO THE LEVEL OF THE HIGHEST VENT STACK
FOR A DURATION OF TWO (2) HOURS.
39. FILL AND TEST THE ENTIRE INTERIOR RAIN WATER ASSEMBLY WITH WATER TO THE LEVEL OF THE HIGHEST VENT STACK
FOR A DURATION OF TWO (2) HOURS, IF APPLICABLE.
40. TESTS MUST BE PERFORMED AND ALL SYSTEMS CONFIRMED FOR THEIR INTENDED USE PRIOR TO FINAL PAINTING, COVERING,
INSULATING, FURRING, AND/OR CONCEALING ANY PIPING.
41. UPON COMPLETION OF THE WORK, ALL CHANGES, ALTERATIONS AND MODIFICATIONS SHALL BE NOTED ON A SET OF DRAWING
PRINTS, AND DELIVERED TO THE ARCHITECT.
PLUMBING NOTES
G
HW
CW COLD WATER LINE
HOT WATER LINE
FUEL GAS LINE
SANITARY WASTE (DRAIN) LINE
(E) SANITARY WASTE (DRAIN) LINE
VENT PIPE
DRAINS/FLOOR DRAINS
FLOOR CLEAN OUT
WALL CLEAN OUT
P.O.C. (POINT OF CONNECTION)
S.O.V. (SHUT-OFF VALVE)
L-ANGLE / T-ANGLE
PLUMBING LEGEND
MINIMUM CONNECTION SIZES
TOILET
4" 2" -
1
2
"
FIXTURE S/W VENT DRAIN COLD HOT
WATER WATER
2" 1
1
2
"
-3
4
"
-
-URINAL
2" 1
1
2
"
-LAVATORY
1
2
"
1
2
"
2" 1
1
2
"
-HAND SINK
1
2
"
1
2
"
2" 1
1
2
"
-UTILITY SINK
3
4
"
3
4
"
2" 1
1
2
"
-FLOOR SINK
- -
MAXIMUM WATER USAGE
TOILET 1.6 GAL. PER FLUSH MAX.
FIXTURE USAGE
1.0 GAL. PER FLUSH MAX.URINAL
0.5 GAL. PER MINUTE MAX.LAVATORY
0.5 GAL. PER MINUTE MAX.HAND SINK
0.5 GAL. PER MINUTE MAXUTILITY SINK
0.5 GAL. PER MINUTE MAXFLOOR SINK
2.5 GAL. PER MINUTE MAXSHOWERHEAD
ALL PLUMBING FIXTURES AND OPERATING VALVES AND
CONTROLS SHALL BE CALIFORNIA ENERGY COMMISSION
(CEC) APPROVED
PLUMBING MATERIALS
SOIL, WASTE, DRAIN, AND VENT LINES: SCHEDULE 40 ABS PER ASTM F628 OR
ASTM D 2661 AND ABS FITTINGS FOR DWV APPLICATIONS. JOINTS AND
FITTINGS SHALL COMPLY WITH THE MANUFACTURER'S INSTALLATION
INSTRUCTIONS.
ALL PRODUCTS SHALL BEAR THE SEAL OF A NATIONALLY RECOGNIZED
CERTIFYING AGENCY. JOIN ABS COMPONENTS WITH "MEK" SOLVENT CEMENT
FOR ABS DWV PER ASTM D 2235. MAINTAIN 4'-0" LENGTH MAXIMUM BETWEEN
HANGER SUPPORTS. PROVIDE FOR FREE MOVEMENT, EXCEPT UPWARD
MOVEMENT SHALL BE RESTRICTED.
CONTROL EXPANSION AND CONTRACTION WITH EXPANSION JOINTS, GUIDES,
CLAMPED FLEXIBLE CONNECTORS, HUBLESS COUPLINGS AND OFFSET PIPING
CONFIGURATIONS
WATER LINES: TYPE "L" COPPER. ANY UNDER SLAB WATER LINES SHALL BE
TYPE "K" DRAWN COPPER. ALL COPPER FITTINGS SHALL COMPLY WITH ASTM
B88. ALL COPPER PIPING SHALL BE REAMED TO FULL INSIDE DIAMETER. USE
LISTED FLUX AND LEAD FREE SOLDER. INSULATE ALL HOT WATER PIPING
LINES WITH ONE-INCH THERMOCELL INSULATION, PER CPC, 2013 ED.
GAS PIPING: ABOVE GRADE GAS PIPING SHALL BE 150 PSI SCHEDULE 40. ALL
EXTERIOR BURIED GAS PIPING SHALL BE FACTORY WRAPPED SCHEDULE 40
WITH ALL JOINTS PRIMED AND WRAPPED TWICE WITH 20 MIL TAPE, OR SHALL
BE GAS RATED PIPING WITH TRACER WIRE. PE GAS PIPING MUST BE AIR
TESTED TO 60PSI FOR 30 MINUTES DURATION.
BURIED PE GAS PIPING SHALL HAVE A LISTED STEEL TRANSITION TO ABOVE
GROUND INSTALLATION. FITTINGS SHALL BE MALLEABLE IRON FITTINGS
SPECIFIED FOR STEEL GAS PIPING.
VALVES: ALL VALVES SHALL HAVE BRASS BODIES RATED TO 125PSI, NIBCO,
OR EQUAL. WATER SHUT OFF VALVES SHALL BE FULL PORT BALL VALVES,
UNO PER CPC, 2013 ED.
P-2: PLUMBING PLAN
A-2: AEC DEMO PLAN
A-4: AEC IMPROVEMENT PLAN
SCALE:
1
32
" = 1'-0"
UPPER LEVEL KEY PLAN
AEC BLDG
P-2: PLUMBING PLAN
A-2: AEC DEMO PLAN
A-4: AEC IMPROVEMENT PLAN
MAXIMUM HANGER SPACING
PIPE TYPE HORIZONTAL VERTICAL
SCHEDULE 40
ABS DWV
& PVC DWV
ALL: 48-INCH MAX.
ALLOW FOR EXPANSION
BASE & EACH FLOOR
PROVIDE FOR
EXPANSION EVERY
30'-0"
CAST IRON EVERY OTHER JOINT BASE & EACH FLOOR
HUBLESS UNLESS OVER 4'-0" THEN
SUPPORT EACH SIDE OF
JOINT 1'-6" MAXIMUM
15'-0" MAXIMUM
COPPER PIPE
1
1
2
" & SMALLER: 6' MAX.
2" & LARGER: 10' MAX.
EACH FLOOR
STEEL GAS
1
2
": 6'-0" MAX.
3
4
" & 1": 8'-0" MAX.
1
1
4
" & LARGER: 10' MAX.
1
1
4
" & LARGER EACH
FLOOR
HANGER SPACING NOTES
1. HANGERS SHALL NOT BE PLACED ON COUPLINGS.
2. FOR MECHANICALLY-JOINTED PIPING, NO PIPE LENGTH MAY BE
LEFT UNSUPPORTED BETWEEN ANY TWO COUPLINGS.
3. USE HANGERS WITH 1
1
2
" MINIMUM VERTICAL ADJUSTMENT.
4. PROVIDE SEISMIC BRACING FOR ALL PIPING THAT IS 1-INCH AND
LARGER EXCEPT WHERE THE TOP OF THE PIPE IS SUSPENDED
12-INCHES OR LESS BY AN INDIVIDUAL HANGER PER PPIC/SMACNA.
SUPPORT PIPING AT HORIZONTAL BRANCH CONNECTIONS
PIPE SIZE MINIMUM HANGER ROD DIAMETER
1
2
" - 1"
3
8
"
1
1
2
" - 2"
3
8
"
2
1
2
" - 3"
1
2
"
PVC (ALL SIZES)
3
8
"
PLUMBING FIXTURE SCHEDULE
ITEM FIXTURE
TOILET H.C.
TOILET TYP.
KOHLER KINGSTON TOILET #K-4325 (WHITE)
w/ #K-4731-C SEAT & ZURN #ZER6000AV-CPM
(1.6 GPF)
KOHLER KINGSTON TOILET #K-4325 (WHITE) w/
#K-4731-C SEAT & SLOAN #111-1.6 HET (1.6 GPF)
LAVATORY
IN COUNTERCHICAGO FAUCET #802-V 317ABCPD
KOHLER TAHOE LAVATORY #K-2890-4U (WHITE)
UNDERCOUNTER MOUNT
LAVATORY
WALL HUNG
DESCRIPTION
CHICAGO FAUCET #802-V 317ABCPD
KOHLER KINGSTON LAVATORY #K-2005 (WHITE)
WALL-HUNG
URINAL TYP.
KOHLER DEXTER URINAL #K-0-5016-ET (WHITE)
w/ SLOAN #186-0.5 HEU (0.5 GPF)
PROVIDE QUARTER TURN SUPPLY VALVES
PROVIDE QUARTER TURN SUPPLY VALVES
OR ZURN #ZER 6003AV-CPM FLUSH VALVE
AT ACCESSIBLE URINALS
4" 1
1
2
"
-FLOOR DRAIN
1
2
"
-
AEC: EVENT CENTER
MEN & WOMEN
RESTROOMS
PLUMBING NOTES
CW
HWR
HW
HCHC HC HC
CW
CW
CW
CW
CW
HWR
HW
HC HC HCHCHCHC C
VENTURA COUNTY
COMMUNITY
COLLEGE DISTRICT
VENTURA COLLEGE
4667 Telegraph Road
Ventura, CA 93003
AEC GYMNASIUM
MEN & WOMEN
RESTROOM
RENOVATION
PROJECT DIRECTORY
SOILS ENGINEER / SEPTIC SYSTEM:
XXXX
CIVIL ENGINEER:
XXXX
STRUCTURAL ENGINEER:
XXXX
ELECTRICAL ENGINEER:
LUCCI & ASSOCIATES
805/389.6520
MECHANICAL ENGINEER:
A/E GROUP
805/653.1722
LANDSCAPE ARCHITECT:
XXXX
WATER SYSTEM / FIRE PROTECTION SYSTEM:
XXXXt
THIS PLAN IS BASED UPON DATA COMPILED
AND FURNISHED BY OTHERS.
BUILDING AND SAFETY - SUBMITTAL
SHEET NAME
DATE
SCALE
PROJECT
SHEET NUMBER OF SHEETS
C15 - 007
00
ROY E COLBERT
ARCHITECTURE
PLANNING
DESIGN
353 SAN JON ROAD
VENTURA, CA 93001
805 / 650 . 9590 PH
805 / 650 . 9589 FX
CALIFORNIA C12050
N.C.A.R.B.
AS SHOWN
This project has been designed by me, or
under my direct supervision.
PRELIMINARY - NOT FOR CONSTRUCTION
PLANNING - SUBMITTAL
.
ISSUED FOR CONSTRUCTION
PLUMBING KEY NOTES
P4
P2
P3
P1
P7
P6
P5
P8
P9
P10
P11
P12
P13
P14
P15
P16
P17
P18
P19
P20
P21
P22
P23
15-007:AEC: P-2
P24
P25
P26
P27
20'-9
1
2
"
21'-3
1
2
"
1'-1"
28'-10
3
4
"
6'-0"
22'-10
3
4
"
6'-0"
14'-1
1
2
"
20'-6"
1'-5
1
2
"
3'-0"3'-0"3'-0"3'-0"
F.O
.S
.
FIN
.
1'-6"
5'-0
1
2
"
3'-0"
3'-1"
2'-7"
2'-7"
2'-7"
2'-7"
2'-7"
1'-3"
℄℄
℄
℄℄
℄℄
℄℄
FIN.
F.O.C.
℄℄℄℄℄
F.O
.S
.
F.O
.C
.
1'-5
1
2
"
3'-0"3'-0"
℄℄℄
2'-6"
℄ ℄2'-6"
℄2'-6"
℄2'-6"
℄2'-6"
℄4'-0"
℄
3'-0"
3'-1"
℄℄
1'-6
1
2
"
5'-10
7
8
"
1'-0
3
4
"
2'-6"
℄ ℄2'-6"
℄2'-6"
℄2'-0"
SCALE:
1
2
" = 1'-0"
AEC: WOMEN'S PLUMBING PLAN
(E) CONCRETE WALL TO REMAIN
(E) CONCRETE WALL TO REMAIN
(E) CONCRETE STAIR TO REMAIN
P20P25
P26
P13 P13
P2 P3
P1 P1
(E) CONCRETE WALL TO REMAIN
℄
F.O.S.
P11 P6 P13
P20
P28
P28
P1
P29
P29
(E) 4-INCH C.I. WASTE TO REMAIN
(E) 3" C.W. / 1
1
2
" H.W. /
1
2
" H.W.R. OVERHEAD IN CLG
TO REMAIN
(E) 2" C.W. / 1
1
4
" H.W. /
1
2
" H.W.R. OVERHEAD IN CLG
TO REMAIN
(N) ZURN FLOOR DRAIN & 2-INCH WASTE w/ TRAP
PRIMER PER VENTURA COLLEGE
P4
P4P4
P4
P4
FIN
.
FIN.
1'-6"
FIN.
FIN
.
FIN
.
P1
(E) C.O.T.G. TO REMAIN
P5
P1
(N) 3" ABS LATERAL
P7
P8
P6
(N) 2" ABS LATERAL
P8
(N) 4" ABS LATERAL
P8
P8
P8
P7
SCALE:
1
2
" = 1'-0"
AEC: MEN'S PLUMBING PLAN
P6
P1
P6
(E) 2
1
2
" VTR
(E) 2" VTR
(E) 4" SANITARY WASTE LINE DOWN TO BELOW
TO REMAIN
P9
P11
P10
(E) 2" SANITARY WASTE LINE DOWN TO BELOW
TO REMAIN
P12P10
OFFSET
IN CLG
(N) 2" VENT
P13
P13
P13
P13
P13
P6
P6
WALL TILE INSTALLED
DIRECTLY ON CONCRETE WALL
(E) 2
1
2
" VTR & 4" SANITARY WASTE DOWN TO BELOW
TO REMAIN
P14
(N) WALL CLEAN OUT w/ STAINLESS STEEL
ACCESS PANEL
P15
P15
P15
P15
P15P15
P8
1
2
" C.W. TO FLOOR DRAIN TRAP PRIMER
P16
P16
P16
P8
(N) 2" C.W. DOWN w/in FRAMING / PROVIDE
SHUT-OFF VALVE IN RISER WITH ACCESS PANEL
P17
2"
1
2
"
3
4
"
1"
1
1
4
"
1
1
4
"
1"
3
4
"
1
1
4
"
1
1
2
"
P171
1
2
"
1
2
"
1
1
4
"
P6
P19
(N)
3
4
" H.W. DOWN w/in FRAMING / PROVIDE
SHUT-OFF VALVE IN RISER WITH ACCESS PANEL
(N) 1" C.W. DOWN w/in FRAMING / PROVIDE
SHUT-OFF VALVE IN RISER WITH ACCESS PANEL
P18
SHUT-OFF VALVE w/ STAINLESS STEEL ACCESS
PANEL
(E) 3-INCH COLD WATER
P21
P21
P16
P16
P16
P15
P15
P15
P15
P15
P8 P13
PLUMBING FIXTURE SCHEDULE
ITEM FIXTURE
TOILET H.C.
TOILET TYP.
KOHLER KINGSTON TOILET #K-4325 (WHITE) w/
#K-4731-C SEAT & ZURN #ZER6000AV-CPM (1.6 GPF)
KOHLER KINGSTON TOILET #K-4325 (WHITE) w/
#K-4731-C SEAT & SLOAN #111-1.6 HET (1.6 GPF)
LAVATORY
IN COUNTER
CHICAGO FAUCET #802-V 317ABCPD
KOHLER TAHOE LAVATORY #K-2890-4U (WHITE)
UNDERCOUNTER MOUNT
LAVATORY
WALL HUNG
DESCRIPTION
CHICAGO FAUCET #116.211.AB.1 (ELECTRONIC)
KOHLER KINGSTON LAVATORY #K-2005 (WHITE)
WALL-HUNG
URINAL TYP.
KOHLER STANWELL URINAL #K-4972-ET (WHITE) w/
SLOAN #186-0.5 HEU (0.5 GPF)
P22
INSTALL CLEAN OUT ABOVE EACH URINAL w/
STAINLESS STEEL ACCESS PANEL
EXPOSE THIS (E) CHASE
DURING DEMOLITION FOR
ACCESS TO PLUMBING
(E) F.C.O. @ TICKET BOOTH
20'-2
1
2
"
INSTALL ELKAY # LZSG8WSSK DRINKING
FOUNTAIN
A-5
6
P24
P24
THE LOCATIONS AND SIZES SHOWN ON DRAWINGS P-2,
P-3 & A-6 ARE SCHEMATIC ONLY. COORDINATE THE
LOCATIONS AND SIZES OF THE WALL ACCESS PANELS
WITH VENTURA COLLEGE.
1'-7
1
2
"
℄
1'-7"
℄℄
F.O.S.
1'-7"
℄
FIN.
3
4
" C.W. HOSE BIBB CHROME FINISH w/ CHROME
ESCUTCHEON RING - KEYED
AEC: EVENT CENTER
MEN & WOMEN
RESTROOMS
PLUMBING PLANS
9"
8"
6"
27
"
17"
VENTURA COUNTY
COMMUNITY
COLLEGE DISTRICT
VENTURA COLLEGE
4667 Telegraph Road
Ventura, CA 93003
AEC GYMNASIUM
MEN & WOMEN
RESTROOM
RENOVATION
PROJECT DIRECTORY
SOILS ENGINEER / SEPTIC SYSTEM:
XXXX
CIVIL ENGINEER:
XXXX
STRUCTURAL ENGINEER:
XXXX
ELECTRICAL ENGINEER:
LUCCI & ASSOCIATES
805/389.6520
MECHANICAL ENGINEER:
A/E GROUP
805/653.1722
LANDSCAPE ARCHITECT:
XXXX
WATER SYSTEM / FIRE PROTECTION SYSTEM:
XXXXt
THIS PLAN IS BASED UPON DATA COMPILED
AND FURNISHED BY OTHERS.
BUILDING AND SAFETY - SUBMITTAL
SHEET NAME
DATE
SCALE
PROJECT
SHEET NUMBER OF SHEETS
C15 - 007
00
ROY E COLBERT
ARCHITECTURE
PLANNING
DESIGN
353 SAN JON ROAD
VENTURA, CA 93001
805 / 650 . 9590 PH
805 / 650 . 9589 FX
CALIFORNIA C12050
N.C.A.R.B.
AS SHOWN
This project has been designed by me, or
under my direct supervision.
PRELIMINARY - NOT FOR CONSTRUCTION
PLANNING - SUBMITTAL
.
ISSUED FOR CONSTRUCTION
H.C. COUNTER TOP SUPPORT DTL - TYPICAL
3
4
" GRANITE "LUNA PEARL" COUNTER TOP
PACIFIC STONEWORKS INC. 31 PEKING ST.
VENTURA, CA 93001 [805/ 648.4098]
1
1
2
" x 1
1
2
" x 18" x
3
16
" STEEL ANGLE
SHOP WELD TO FLAT STOCK
SEAL PENETRATION w/ TILE & GROUT
PORCELAIN WALL TILE: FLORIANA "HEATHER" 12" x 24"
GROUT: TEC ADVANCED PERFORMANCE #940
ANTIQUE WHITE
2" x 16" x
3
16
" FLAT STEEL STOCK
SECURE TO STUDS w/ (8)-
1
4
" x 1
1
4
"
SDS SCREWS STAGGERED @ 2" O.C.
1'-6"
3
4
" CD PWD SUBSTRATE - GLUE & SCREW TO
STEEL ANGLE w/ (3)
1
4
"
Ï
x
3
4
" R.HD. WD. SCREWS
1'-10" FIELD VERIFY w/ KOHLER "TAHOE" LAVATORY
1'-4
"
SCALE: 3" = 1'-0"
2"
THINSET MORTAR: WHITE, FOR PORCELAIN
1x EDGE BLOCK'G
5"
WALL HUNG TOILET FIXTURE SUPPORT - TYPICAL
SCALE: 3" = 1'-0"
MFR'S BOLTS FROM
TOILET INTO SUPPORT
MFR'S BOLTS FROM
TOILET INTO SUPPORT
(E) DRAIN
(N) 3 x SILL P.T.D.F.
BEYOND & FOREGROUND
LOCATION FOR
3"Ï DRAIN
1'-8
"
BASE SUPPORT
INSULATE DRAIN LINE
PER C.B.C. 11B-606
2'-1
0"
CLEAR UNOBSTRUCTED
SPACE AT ACCESSIBLE
LAVATORIES
PER C.B.C. 11B-305.2, 11B-305.3,
11B-606.2
1'-7
"
A.D.A.: ZURN 6000AV-WS1-CPM (1.6 GPF)
AUTOMATIC FLUSH VALVE ASS'Y
OTHER: SLOAN ROYAL 111-1.6 HET
MANUAL FLUSH VALVE ASS'Y
KOHLER KINGSTON K-4325
SIPHON-JET w/ SEAT K-4731-C
1
1
2
"
Ï
SPUD
OUTLET COUPLE
& GASKET
FIN. FLOOR TILE o/ THINSET MORTAR
o/ CUSTOM "REDGARD" MEMBRANE
JAY R. SMITH #210
FIXTURE SUPPORT FOR
SIPHON JET TOILET,
OR KOHLER EQUAL
ADD/INSERT
5
32
" STEEL PLATE (VERTICAL) AT MOUNTING SCREWS FOR ADD'L SUPPORT
1
4
MFR'S BOLTS FROM
TOILET INTO SUPPORT
ZURN FLOOR DRAIN, SQUARE TOP
FLUSH WITH FLOOR TILES
BRASS w/ SATIN FINISH
SECONDARY DRAIN COLLAR
FOR MEMBRANE
NEW FLOOR TILE o/ THINSET
o/ ISOLATION MEMBRANE
(E) CONC. FLOOR SLAB
SAWCUT AS REQUIRED
FOR (N) FLOOR DRAIN
INSTALLATION
TRAP PRIMER CONNECTION
@ FLOOR DRAIN
OUTLET SIZED FOR
NO HUB CONNECTION
LATERAL DRAIN LINE
(N) P-TRAP
REFER TO ARCHITECTURAL
FLOOR PLANS FOR LOCATION.
COORDINATE INSTALLATION
w/ FLOOR FINISH & WATERPROOFING
FLOOR DRAIN DETAIL
SCALE: 3" = 1'-0"
3
1
2
" COPPER TYPE L
WATER LINE
1'-4
"
14" x 16" HT. STAINLESS STEEL
#304 / 22 GAUGE #4 FINISH
ACCESS ASS'Y w/ DOOR
w/in FRAMED OPENING
COLD WATER SUPPLY LINE
1
2
" BALL VALVE
QUARTER TURN
UNION
TRAP PRIMER
AIR GAP FITTING
+ 6" A.F.F.
1
2
" TO FLOOR DRAIN TRAP
PRIMER CONNECTION
TRAP PRIMER DETAIL
SCALE: 3" = 1'-0"
2
EASED ALL EXPOSED EDGES
AT SIDE AND TOP EDGES
LOCATION OF (E) FLOOR DRAIN TO REMAIN, U.N.O.
REDUCE WATER PRESSURE
TO 10 PSI TO FLOOR DRAIN
WALL FRAMING
ADD 2x FRAMING
FOR ADD'L SUPPORT
2x BLOCKING
PORCELAIN WALL TILE: FLORIANA "HEATHER" 12" x 24"
GROUT: TEC ADVANCED PERFORMANCE #940
ANTIQUE WHITE
THINSET MORTAR: WHITE, FOR PORCELAIN
3
4
"
1
2
" DUROCK BACKER BOARD TO 8-FT
OVER 6 MIL POLYETHYLENE MOISTURE BARRIER
WITH 1
1
4
" SUPERIOR-BIT BACKER BOARD SCREWS
AT 8" O.C. (SEE T.C.A. DETAIL #EJ-171)
1
2
" DUROCK BACKER BOARD TO 8-FT HEIGHT MIN.
OVER 6 MIL POLYETHYLENE MOISTURE BARRIER
WITH 1
1
4
" SUPERIOR-BIT BACKER BOARD SCREWS
AT 8" O.C. (SEE T.C.A. DETAIL #EJ-171)
2'-5
"
VERIFY 17" - 19" HEIGHT A.F.F.
TO COMPLY WITH C.B.C. 11B-604.4
1
2
" DUROCK BACKER BOARD TO 8-FT HEIGHT MIN.
OVER 6 MIL POLYETHYLENE MOISTURE BARRIER
WITH 1
1
4
" SUPERIOR-BIT BACKER BOARD SCREWS
AT 8" O.C. (SEE T.C.A. DETAIL #EJ-171)
PORCELAIN WALL TILE: FLORIANA "HEATHER" 12" x 24"
GROUT: TEC ADVANCED PERFORMANCE #940
ANTIQUE WHITE
VERIFY DIMENSIONS OF THE FIXTURE SUPPORT UNIT WITH THE KOHLER TOILET
LET-IN
5
32
" STEEL PLATE
FOR ADD'L SUPPORT
VERIFY 2'-10" HEIGHT A.F.F.
TO COMPLY WITH C.B.C. 11B-606.3
KOHLER "TAHOE" #K-2890-4U
UNDER-MOUNT LAVATORY
GRANITE FACE MITER TO TOP
AS SHOWN
THIS DIMENSION MAY BE INCREASED TO ALLOW FOR
THE UNDER-MOUNT LAVATORY AND THE CHICAGO FAUCET
SCHLUTER "DILEX-HKUE" 316 L STAINLESS STEEL COVE
AMERICAN OLEAN SH52 FLOOR TILE o/ THINSET MORTAR
o/ CUSTOM "REDGARD" MEMBRANE
THINSET MORTAR: WHITE, FOR PORCELAIN
INSTALL THESE SUPPORT
ASSEMBLIES @ 2'-6" O.C.
BETWEEN LAVATORIES
SCHLUTER 10E 316L
COVE BASE TRIM - TYP.
RESINOUS EPOXY FLOOR SURFACE
AT C BUILDING RESTROOMS
RESINOUS EPOXY FLOOR SURFACE
AT C BUILDING RESTROOMS
ADJUSTMENT SCREW
w/ LOCK NUT
15-007:AEC: P-3
AEC: EVENT CENTER
MEN & WOMEN
RESTROOMS
PLUMBING DETAILS
VENTURA COUNTY
COMMUNITY
COLLEGE DISTRICT
VENTURA COLLEGE
4667 Telegraph Road
Ventura, CA 93003
AEC GYMNASIUM
MEN & WOMEN
RESTROOM
RENOVATION
PROJECT DIRECTORY
SOILS ENGINEER / SEPTIC SYSTEM:
XXXX
CIVIL ENGINEER:
XXXX
STRUCTURAL ENGINEER:
XXXX
ELECTRICAL ENGINEER:
LUCCI & ASSOCIATES
805/389.6520
MECHANICAL ENGINEER:
A/E GROUP
805/653.1722
LANDSCAPE ARCHITECT:
XXXX
WATER SYSTEM / FIRE PROTECTION SYSTEM:
XXXXt
THIS PLAN IS BASED UPON DATA COMPILED
AND FURNISHED BY OTHERS.
BUILDING AND SAFETY - SUBMITTAL
SHEET NAME
DATE
SCALE
PROJECT
SHEET NUMBER OF SHEETS
C15 - 007
00
ROY E COLBERT
ARCHITECTURE
PLANNING
DESIGN
353 SAN JON ROAD
VENTURA, CA 93001
805 / 650 . 9590 PH
805 / 650 . 9589 FX
CALIFORNIA C12050
N.C.A.R.B.
AS SHOWN
This project has been designed by me, or
under my direct supervision.
PRELIMINARY - NOT FOR CONSTRUCTION
PLANNING - SUBMITTAL
.
ISSUED FOR CONSTRUCTION
SCALE:
1
4
" = 1'-0"
AEC: WOMEN'S HVAC PLAN AEC: MEN'S HVAC PLAN
SCALE:
1
4
" = 1'-0"
15-007:AEC: M-1
AEC: EVENT CENTER
MEN & WOMEN
RESTROOM
HVAC DUCT PLANS
NOTES:
1. MECHANICAL PLANS SHOW THE EXISTING OVERHEAD HVAC DUCTS
2. AEC - BUILDING DUCTS SHALL REMAIN WITHIN (E) ATTIC SPACE
3. C - BUILDING DUCTS SHALL REMAIN IN THE EXISTING SOFFITS (@ 7'-2" A.F.F.)
4. VERIFY THE EXISTING CONDITIONS AND COORDINATE WITH VENTURA COLLEGE
REPLACE (E) w/ (N) WHITE
COVER GRILLE
REPLACE (E) w/ (N) WHITE
COVER GRILLE
VENTURA COUNTY
COMMUNITY
COLLEGE DISTRICT
VENTURA COLLEGE
4667 Telegraph Road
Ventura, CA 93003
AEC GYMNASIUM
DOOR REPLACEMENT
INTERIOR IMPROVEMENT
PROJECT DIRECTORY
SOILS ENGINEER / SEPTIC SYSTEM:
XXXX
CIVIL ENGINEER:
XXXX
STRUCTURAL ENGINEER:
XXXX
ELECTRICAL ENGINEER:
XXXX
MECHANICAL ENGINEER:
XXXX
LANDSCAPE ARCHITECT:
XXXX
WATER SYSTEM / FIRE PROTECTION SYSTEM:
XXXXt
THIS PLAN IS BASED UPON DATA COMPILED
AND FURNISHED BY OTHERS.
BUILDING AND SAFETY - SUBMITTAL
SHEET NAME
DATE
SCALE
PROJECT
SHEET NUMBER OF SHEETS
C16 - 011
00
ROY E COLBERT
ARCHITECTURE
PLANNING
DESIGN
1997 EAST MAIN STREET
VENTURA, CA 93001
805 / 650 . 9590 PH
805 / 650 . 9589 FX
CALIFORNIA C12050
N.C.A.R.B.
AS SHOWN
This project has been designed by me, or
under my direct supervision.
ISSUE FOR CONSTRUCTION
PLANNING - SUBMITTAL
PRELIMINARY - NOT FOR CONSTRUCTION
REQUIREMENTS OF CALIFORNIA ADMINISTRATIVE CODE, TITLE 24
TRUE NORTH ANGLE, RELATIVE TO "REFERENCE NORTH" SHOWN ON
THE BUILDER SHALL PROVIDE THE OWNER WITH INSTRUCTIONS ON
THE EFFICIENT USE OF LIGHTING AND MECHANICAL SYSTEM
VENTURA COUNTY COMMUNITY COLLEGE DISTRICT
VENTURA COLLEGE
GENERAL REQUIREMENTS
2.
CONSTRUCTION:
2013 CBC - CALIFORNIA BUILDING CODE
2013 CEC - CALIFORNIA ELECTRICAL CODE
2013 CPC - CALIFORNIA PLUMBING CODE
2013 CMC - CALIFORNIA MECHANICAL CODE
2013 CEnC - CALIFORNIA ENERGY CODE
2013 CFC - CALIFORNIA FIRE CODE
2013 CAC - CALIFORNIA ADMINISTRATIVE CODE
2013 CALIFORNIA REFERENCED STANDARDS CODE
NUMBER OF EXITS: 31 (AEC & C)
HEIGHT: TWO- STORY
FIRE SPRINKLERS EXISTING: NONE
THE PLANS: +
COMPONENTS.
3.
APPLICABLE CODES
FIRE PROTECTION
PROJECT ANALYSIS
VENTURA COLLEGE
OCCUPANCY: E
CODE ANALYSIS
CONSTRUCTION IS TO COMPLY WITH ALL APPLICABLE
SCOPE OF THE WORK
1.
TITLE 24 - ENERGY
ARCHITECTURAL
A-0
A-1
A-2
COVER SHEET
KEY PLAN / DOOR ELEVATIONS
DOOR HARDWARE SCHEDULE
SHEET INDEX
VICINITY MAP
FIN FLR FINISHED FLOOR ELEVATION
CONT CONTINUOUSALT. ALTERNATEFBO FURNISHED BY OTHERS
CSMNT. CASEMENT
CATV CABLE TELEVISION
C.I. CAST IRON
CLG CEILING
A/C AIR CONDITIONING
ANNOD. ANNODIZED
ARCH('L) ARCHITECT(URAL)
AUTO. AUTOMATIC
B.M. BENCHMARK
B.U.R. BUILT UP ROOF
BTTM. BOTTOM
CAB'T CABINET
BLDG. BUILDING
AL. ALUMINUM
BTWN. BETWEEN
D.F. DOUGLAS FIR
(E) EXISTING
ENCL ENCLOS(UR)E
EQ EQUAL
CU FT CUBIC FEET
DIA DIAMETER
DIM DIMENSION
DISP DISPENSER
DIV DIVISION
D DEPTH
DWG DRAWING
CFM CUBIC FEET PER MINUTE
DEMO DEMOLISH, DEMOLITION
D.H. DOUBLE HUNG
DS DOWN SPOUT
HORIZ HORIZONTAL
HB HOSE BIBB
I.D. INSIDE DIAMETER
INSUL INSULATION
GA GAGE, GAUGE
GALV GALVANIZED
GL. GLASS, GLAZING
GB. GLASS BLOCK
HDBD. HARD BOARD
HD HEAVY DUTY
HC HOLLOW CORE
HM HOLLOW METAL
FUT FUTURE
HWD HARDWOOD
HT. HEIGHT
ABBREVIATIONS
DRAWING SYMBOLS
ADJ. ADJACENT
ASS'Y. ASSEMBLY
A.B. ANCHOR BOLT
DETAILS
CMU CONCRETE MASONRY UNIT
CONC. CONCRETE
COL COLUMN
DETAILS
BUILDING SECTIONS
FLUOR. FLUORESCENT
FTG. FOOTING
N I C NOT IN CONTRACT
SHT SHEET
VERT VERTICAL
STD. STANDARD
S.H. SINGLE HUNG
S C SOLID CORE
SPEC('S). SPECIFICATION(S)
SQ FT SQUARE FOOT
T.S. TUBE SECTION
SST' L STAINLESS STEEL
THK THICKNESS
T&G. TONGUE AND GROOVE
PTDF PRESSURE TREATED DOUGLAS FIR
PSF POUNDS PER SQUARE FOOT
PSI. POUNDS PER SQUARE INCH
PL. PLATE, PROPERTY LINE
PWD PLYWOOD
PTN PARTITION
PLAS LAM PLASTIC LAMINATE
N.T.S. NOT TO SCALE
O C ON CENTER
OPNG. OPENING
OPP OPPOSITE
O D OUTSIDE DIAMETER
O'HEAD OVERHEAD
PH PHONE
TYP TYPICAL
SYS. SYSTEM
ST'L. STEEL
SIM SIMILAR
SECT. SECTION
R O ROUGH OPENING
ROW RIGHT OF WAY
NWF. NATURAL WOOD FINISH
LIN FT LINEAL FOOT
(N) NEW
LTWT LIGHT WEIGHT
GRID / COLUMN REFERENCE LINE
A
1
DATUM / LEVEL LINE
RF ROOF
(F.G) FINISH GRADE
(T.P.) TOP OF PAVEMENT
POINT ELEVATIONS
CONSULTANTS
C16-011:C / A-0
AEC & C:
DOOR REPLACEMENT
SCOPE OF WORK:
REMOVE AND REPLACE SEVEN (7) DOORS IN THE ATHLETIC EVENT CENTER (AEC) AND
FOUR (4) DOORS IN THE PHYSICAL EDUCATION GYMNASIUM (C) BUILDING.
SINCE THESE EIGHT (11) DOOR ASSEMBLIES ARE ANCHORED INTO THE EXISTING SOLID
CONCRETE WALLS, THE METAL FRAMES SHALL REMAIN WHERE FEASIBLE
AND PROTECTED IN PLACE.
THESE DOORS CURRENTLY SERVE AND SHALL REMAIN AS REQUIRED EXITS.
REPAIR AND REINFORCE THE DOOR ASSEMBLIES AS NECESSARY FOR THE INTENDED USE.
DEMO NOTES
REMOVE ALL (E) ASSEMBLY COMPONENTS WHERE SHOWN TO COMPLETE THE WORK.
PROTECT THE ADJACENT SURFACES.
ACCESSIBILITY NOTES
1. THE DRAWINGS ARE INTENDED ONLY TO CONVEY DESIGN INTENT. THE PLANS AND SPECIFICATIONS SHALL
NOT BE CONSIDERED AS EITHER A LIST OF PARTS OR ASSEMBLY INSTRUCTIONS. THE SPECIFICATIONS ARE
INCLUDED WITH THESE DRAWINGS AND DEFINE ADDITIONAL WORK TO BE ACCOMPLISHED.
2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REVIEW OF ALL OF THE CONTRACT DOCUMENTS, TO
EXAMINE THE PROJECT SITE AND TO FAMILIARIZE HIMSELF WITH THE TOTAL SCOPE OF THE WORK AND THE
INTENT OF THE CONTRACT DOCUMENTS. IT IS INCUMBENT UPON THE THE CONTRACTOR TO NOTIFY THE
ARCHITECT IMMEDIATELY UPON THE DISCOVERY OF ANY DISCREPANCIES OR CONFLICTS IN THE CONTRACT
DOCUMENTS.
3. DURING THE BIDDING PROCESS THE CONTRACTOR SHALL OBTAIN PROPER WRITTEN CLARIFICATION OF
DISCREPANCIES, CONFLICTS, AND/OR UNCLEAR ITEMS PRIOR TO THE SUBMISSION OF THE BID.
4. DURING CONSTRUCTION, THE CONTRACTOR SHALL NOT PROCEED WITH THE INSTALLATIONS OR
APPLICATIONS OF ANY CONSTRUCTION THAT MAY BE AFFECTED BY DISCREPANCIES AND/OR CONFLICTS
UNTIL SUCH ISSUES ARE RESOLVED.
5. IT SHALL BE UNDERSTOOD THAT ALL CONTRACTORS AND THEIR PERSONNEL ARE PROPERLY TRAINED AND
EXPERIENCED TO PERFORM THE CONSTRUCTION WORK, AND TO OTHERWISE CARRY OUT THE INTENT OF
THE WORK INCORPORATED INTO THE CONSTRUCTION DRAWINGS AND SPECIFICATIONS.
6. THE CONTRACT DOCUMENTS CONSIST OF THE THE COMPLETE PLAN DRAWINGS, SPECIFICATIONS, REPORTS,
BIDDING INFORMATION AND OTHER INFORMATION PREPARED BY THE ARCHITECT, THE ARCHITECT'S
CONSULTANTS, OR CONSULTANTS HIRED BY THE OWNER. IN THE EVENT OF DISCREPANCIES OR CONFLICTS
IN THE CONTRACT DOCUMENTS, THE INFORMATION CONTAINED IN THE WRITTEN SPECIFICATIONS SHALL
TAKE PRECEDENCE OVER THE DRAWINGS, AND FURTHER, LARGE SCALE DETAIL DRAWINGS SHALL TAKE
PRECEDENCE OVER THE SMALLER SCALE DRAWINGS.
7. WHERE ANY SPECIFIED MATERIAL OR PROCESS IS INDICATED ON THE DRAWINGS OR IN THE
SPECIFICATIONS, IT IS FOR THE PURPOSE MAKING CLEAR THE INTENT REQUIRED TO ACCOMPLISH THE
SCOPE OF THE PROJECT. THE CONTRACTOR MAY OFFER A SUITABLE MATERIAL OR PROCESS TOGETHER
WITH ALL SUPPORTING DOCUMENTATION TO VALIDATE THE EQUIVALENT NATURE TO THE SATISFACTION OF
THE ARCHITECT, THE CONSULTING ENGINEERS, AND TO VENTURA COLLEGE.
8. EACH CONTRACTOR SHALL BE RESPONSIBLE FOR TOTAL COORDINATION OF THEIR OWN WORK AND WITH
THE WORK OF ALL OTHER TRADES. THE CONTRACTOR SHALL PERSONALLY SUPERVISE AND DIRECT THE
PROJECT. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL METHODS OF CONSTRUCTION,
TECHNIQUES, SEQUENCES AND PROCEDURES. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR THE
SAFETY AND PERFORMANCE OF THE WORK, AND FULL COMPLIANCE WITH O.S.H.A., THE U.S. DEPT. OF
LABOR, THE STATE OF CALIFORNIA, AND THE VENTURA COUNTY COMMUNITY COLLEGE DISTRICT
REGULATIONS.
9. ALL THE WORK SHALL CONFORM WITH THE REQUIREMENTS OF THE 2013 EDITION OF THE CALIFORNIA
BUILDING CODE (CBC), AS WELL AS WITH ALL OTHER APPLICABLE FEDERAL REGULATIONS, STATE CODES,
LOCAL CODES, ORDINANCES AND REGULATIONS.
10. ONLY THE APPROVED DRAWINGS WITH THE STATEMENT "ISSUED FOR CONSTRUCTION" ON THE COVER
SHEET ARE TO BE USED FOR CONSTRUCTION ON THIS PROJECT. CONTRACTORS USING OTHER THAN THE
APPROVED DRAWINGS SHALL BE SOLELY RESPONSIBLE FOR SUCH WORK.
11. ALL DIMENSIONS SHOWN ON THE PLAN VIEWS OF THE DRAWINGS ARE TO THE STRUCTURAL FACE OF WALLS,
OR TO THE CENTERLINE OF WALLS, UNLESS NOTED OTHERWISE. DIMENSIONS TO FINISH SURFACES SHALL
BE NOTED AS SUCH.
12. DO NOT SCALE THE DRAWINGS. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS IN THE
FIELD, AND SHALL IMMEDIATELY REPORT ANY DISCREPANCIES OR VARIATIONS TO THE ARCHITECT AND TO
THE OWNER'S REPRESENTATIVE.
13. THE CONTRACTOR SHALL REPAIR AND REPLACE ALL PROPERTY THAT MAY BE DAMAGED BY WORK UNDER
THIS CONTRACT TO THE SATISFACTION OF THE DIRECTOR OF FACILITIES, MAINTENANCE & OPERATIONS OF
VENTURA COLLEGE AND THE ARCHITECT. ALL PIPING, CONDUITS, LINES, ETC., THAT MAY BE ENCOUNTERED
SHALL BE ADEQUATELY SUPPORTED AND PROTECTED UNTIL PERMANENT SUPPORT AND PROTECTION IS
APPROVED, OR UNTIL REMOVAL IS AUTHORIZED.
14. ALL GLAZING SHOWN TO BE INSTALLED IN HAZARDOUS AREAS SHALL COMPLY WITH THE PROVISIONS OF
CBC CHAPTER 24.
15. THE CONTRACTOR SHALL VERIFY ALL ELECTRICAL AND MECHANICAL LOADS THAT IS SCHEDULED TO BE
GENERATED BY THE TENANT'S EQUIPMENT SHOWN ON THE DRAWINGS AND/OR SPECIFIED PRIOR TO
ORDERING THE EQUIPMENT. INFORMATION REGARDING ITEMS THAT MAY AFFECT THE ARCHITECTURAL
NATURE OR STRUCTURE OF THE PROJECT OR EXISTING CONSTRUCTION SHALL BE BROUGHT TO THE
ATTENTION OF THE ARCHITECT IMMEDIATELY.
16. ALL FIRE RESISTIVE CONSTRUCTION SHALL COMPLY WITH THE PROVISIONS OF CBC CHAPTER 7, AND SHALL
BE CONSTRUCTED OF LISTED WALL, FLOOR AND CEILING ASSEMBLIES PER CBC CHAPTER 7, SECTION 716,
AND TABLES 720.1(1), 720.1(2), 720.1(3), AND ADDITIONAL APPROVED ASSEMBLIES LISTED BY THE "GYPSUM
ASSOCIATION DESIGN MANUAL", LATEST EDITION. THESE PROVISIONS INCLUDE LIMITATIONS OF SIZE, TYPE
AND INDIVIDUAL FIRE RATING OF THE PENETRATING ITEM OR ASSEMBLY. NOTE THAT ADDITIONAL
THROUGH-WALL AND MEMBRANE PENETRATIONS SHALL BE PROVIDED WITH "F" AND "T" FIRE BLOCKING AS
DESCRIBED IN CBC CHAPTER 7 FOR THE METHOD OF PENETRATION BEING USED.
17. WALL AND CEILING MATERIALS SHALL NOT EXCEED THE FLAME SPREAD CLASSIFICATIONS IN CBC, TABLE
803.5.
18. ALL STRUCTURAL HOLD-DOWNS SHALL BE SET IN PLACE BY THE USE OF A TEMPLATE PRIOR TO ANY
FOUNDATION INSPECTION. SEE THE STRUCTURAL SHEAR SCHEDULE FOR THE SIZES AND SPACING OF
ANCHOR BOLTS.
19. THE ARCHITECT OR ENGINEER SHALL PERFORM ON-SITE OBSERVATIONS FOR COMPLIANCE WITH THE PLANS
AND SPECIFICATIONS.
20. EACH CONTRACTOR SHALL GUARANTEE, BE RESPONSIBLE FOR, AND MAKE GOOD ANY AND ALL DEFECTS
DUE TO FAULTS OF HIS RESPECTIVE TRADE FOR ALL LABOR, MATERIALS, OR LEAKS FOR ONE (1) YEAR
MINIMUM COMMENCING UPON ACCEPTANCE OF THE COMPLETED PROJECT BY THE BOTH THE ARCHITECT
AND THE DIRECTOR OF FACILITIES, MAINTENANCE AND OPERATIONS OF VENTURA COLLEGE
.
21. THE CONTRACTOR SHALL FURNISH AND BE RESPONSIBLE FOR ADEQUATE SHORING, BRACING, PERIMETER
CHAIN LINK FENCING, AND ALL OTHER PROTECTIVE MEASURES NECESSARY TO SAFELY EXECUTE THE
COMPLETE CONSTRUCTION WORK.
UP
EQUIPMENT ROOM
EXITEXIT
DU
CT
C
HA
SE
EGRESS LOBBY
STORAGE ROOM
STORAGE ROOM
STORAGE
STAIR No. 3
GYM
EXIT
EX
IT
CLASSROOM
GYMGYM
(N) DANCE STUDIO
UP
EXIT
EX
IT
(E) DANCE STUDIO
(E) WOMEN'S LOCKER ROOM
(E) MEN'S LOCKER ROOM
(E) MEN'S TRAINING ROOM
(E) GYMNASIUM
(E) GYMNASIUM
OPEN ACCESS
(N) OPEN TRAINING
103
104
130
131
C-1
C-2
DN
DN
DN
VISITOR TEAM ROOM
(E) SHOWER
(E) SHOWER
(E) SHOWER
(E) SHOWER
(E) SHOWER
(E) EQUIP'T RM
64
(E) LOCKER ROOM
NOTE: CD-2 IS A PLAN OF FLOOR COVERING
THE VISTING TEAM ROOM/WOMEN'S
LOCKER ROOM & EGRESS AREA.
(ref. DWG LR-2)
UP UP
UP
EXITEXIT
EXITEXIT
EX
IT
EX
IT
EX
IT
EX
IT
EXIT EXIT EXIT EXIT
EXIT LOBBYEXIT LOBBY
DR-5 DR-6
DR-7
DR-1
DR-2
DR-4
DR-3
DR-11
EXIT
DR-9
DR-8
EXIT
EXIT
DR-10
OPEN ACCESS
OPEN ACCESS
OPEN ACCESS
(E) MEN'S LOCKER ROOM
(E) EQUIPMENT OFFICE
DR-13
DR-12
EX
IT
EX
IT
DR-14
(E) COACHES OFFICES
NORTH
AEC and C BUILDINGS KEY PLAN - DOOR REPLACEMENT
SCALE:
1
16
" = 1'-0"
SCOPE OF WORK
THIS PROJECT CONSISTS OF THE SELECTED
REMOVAL, RENOVATION AND/OR REPLACEMENT
OF ELEVEN (11) DOOR ASSEMBLIES.
VENTURA COUNTY
COMMUNITY
COLLEGE DISTRICT
VENTURA COLLEGE
4667 Telegraph Road
Ventura, CA 93003
AEC GYMNASIUM
DOOR REPLACEMENT
INTERIOR IMPROVEMENT
PROJECT DIRECTORY
SOILS ENGINEER / SEPTIC SYSTEM:
XXXX
CIVIL ENGINEER:
XXXX
STRUCTURAL ENGINEER:
XXXX
ELECTRICAL ENGINEER:
XXXX
MECHANICAL ENGINEER:
XXXX
LANDSCAPE ARCHITECT:
XXXX
WATER SYSTEM / FIRE PROTECTION SYSTEM:
XXXXt
THIS PLAN IS BASED UPON DATA COMPILED
AND FURNISHED BY OTHERS.
BUILDING AND SAFETY - SUBMITTAL
SHEET NAME
DATE
SCALE
PROJECT
SHEET NUMBER OF SHEETS
C16 - 011
00
ROY E COLBERT
ARCHITECTURE
PLANNING
DESIGN
1997 EAST MAIN STREET
VENTURA, CA 93001
805 / 650 . 9590 PH
805 / 650 . 9589 FX
CALIFORNIA C12050
N.C.A.R.B.
AS SHOWN
This project has been designed by me, or
under my direct supervision.
ISSUE FOR CONSTRUCTION
PLANNING - SUBMITTAL
PRELIMINARY - NOT FOR CONSTRUCTION
AEC: ATHLETIC EVENT CENTER
C: GYMNASIUM
AEC DOOR ELEVATIONS
SCALE:
1
4
" = 1'-0"
REMOVE FOUR (4) PAIRS OF EXISTING H.M. DOORS
REMOVE VERTICAL MULLIONS @ EACH PAIR OF DOORS
INSTALL FOUR (4) PAIRS NEW ALUMINUM STOREFRONT DOORS
FLUSH LOWER PANEL AT ALL FOUR (4) PAIR STOREFRONT DOORS
(E) 2" H.M. FRAMES SHALL REMAIN IN PLACE
NOTE: THESE (E) H.M.FRAMES ARE 'RACKED'
INSTALL (N) CONTINUOUS ALUMINUM HALF MORTISE HINGES
INSTALL (N) PANIC HARDWARE, LOCKS, CLOSERS & PULLS
PROVIDE SHOP DRAWINGS FOR APPROVAL
COMPLY WITH DISABILITY ACCESS REQUIREMENTS
DR-1DR-2 DR-3 DR-4 DR-5
VIEW FROM EXTERIOR - EAST VIEW FROM EXTERIOR - WEST
VIEW FROM EXIT LOBBY VIEW FROM EXIT LOBBY
DR-7 DR-6
6'-1
1
1
2
"
3'-4"
INSTALL FLANGE OF
HALF MORTISE HINGE
o/ FACE OF 2" FRAME
9
1
2
"
R.H.REVL.H.REVR.H.REVL.H.REV R.H.REVL.H.REVR.H.REVL.H.REV R.H.REVL.H.REV R.H.REVL.H.REV R.H.REVL.H.REV
(E) H.M. FRAME
TO REMAIN
THREE (3) PAIRS OF (E) H.M. DOORS SHALL REMAIN
(E) 2" H.M. FRAMES SHALL REMAIN IN PLACE
INSTALL (N) STAINLESS STEEL 4
1
2
" x 4
1
2
" HEAVY DUTY BALL BEARING HINGES
CAREFULLY CONFORM TO (E) HINGE SPREAD
COMPLY WITH DISABILITY ACCESS PER C.B.C., CHAPTER 11B
(E) PAINTED H.M. FRAME
5
1
2
" x 2" TO REMAIN
(E) CONC. WALL
SCHEMATIC JAMB DETAIL
(N) ALUM. DOORS
2'-1
0"
180
180
180
S/S KICK PLATES
@ GYM. SIDE
S/S KICK PLATES
@ GYM. SIDE
180
TYPICAL NOTES & DIMENSIONS
EXTERIOR DOORS #1 THRU #4
6'-1
1
1
2
"
2'-6"
(E) H.M. FRAME
TO REMAIN
3'-0
1
4
"
TYPICAL NOTES & DIMENSIONS
EXTERIOR DOORS #5, #6 & #7
3" = 1'-0"
(E) DRS / HARDWARE
TO REMAIN
KEY PLAN
DOOR ELEVATIONS
16-011: A-1
C-GYM DOOR ELEVATIONS
SCALE:
1
4
" = 1'-0"
DR-11DR-10
DR-9 DR-8
3'-0
1
4
"
3'-0
1
4
"
SIX (6) PAIRS OF (E) 2" x 5" H.M. FRAMES SHALL REMAIN IN PLACE
INSTALL SIX (6) PAIRS OF (N) DOORS
ONE (E) SINGLE DOOR FRAME SHALL REMAIN IN PLACE
INSTALL A SINGLE LEAF ALUMINUM AND GLASS DOOR
INSTALL (N) STAINLESS STEEL HINGES
INSTALL (N) PANIC HARDWARE, LOCKS, CLOSERS & PULLS
COMPLY WITH DISABILITY ACCESS PER C.B.C., CHAPTER 11B
1. SUBMIT SHOP DRAWINGS
2. APPLY A WATER-BASED NON-CHROME CORROSION
PROTECTIVE INORGANIC BASE COATING TO THE
EXISTING STEEL DOOR FRAME PER ASTM F1136/F1136M
3. THOROUGHLY CLEAN AND DEGREASE THE STEEL DOOR
FRAME PRIOR TO APPLYING THE COATING
4. THE FASTENER SCREWS SHALL BE MECHANICALLY ZINC
PLATED WITH A ZINC CHROMATE PRIMER PRIOR TO
INSTALLATION.
5. PROVIDE AND INSTALL WITH PROTECTIVE BUSHINGS
& WASHERS
MID PANEL RAIL
SOLID FLUSH PANEL
1
4
" TEMP. GLASS
6'-1
1
1
2
"
3'-0"
6'-1
1
1
2
"
3'-0"
6'-8
"
3'-0"
6'-1
1
1
2
"
3'-0"
VIEW FROM EXTERIORVIEW FROM EXTERIOR
R.H.REVL.H.REVR.H.REVL.H.REV
R.H.REVL.H.REV R.H.REVL.H.REV
VIEW FROM EXTERIORVIEW FROM EXTERIOR
180180 180 180
90 90 90 90
DR-13DR-12
R.H.REVL.H.REV R.H.REVL.H.REV
VIEW FROM HALLWAYVIEW FROM HALLWAY
180 180180 180
3'-0
1
4
"
OBSCURE
TRANSLUCENT
GLASS LITES
DR-14
R.H.REV
VIEW FROM HALLWAY
180
OBSCURE
TRANSLUCENT
GLASS LITES
6'-1
1
1
2
"
3'-0"
3'-0
1
4
"
CLEAR TEMPERED
GLASS LITE
8" WIDTH
CLEAR TEMPERED
GLASS LITE
8" WIDTH
6'-1
1
1
2
"
3'-0"
3'-0
1
4
"
6'-1
1
1
2
"
3'-0"
VENTURA COUNTY
COMMUNITY
COLLEGE DISTRICT
VENTURA COLLEGE
4667 Telegraph Road
Ventura, CA 93003
AEC GYMNASIUM
DOOR REPLACEMENT
INTERIOR IMPROVEMENT
PROJECT DIRECTORY
SOILS ENGINEER / SEPTIC SYSTEM:
XXXX
CIVIL ENGINEER:
XXXX
STRUCTURAL ENGINEER:
XXXX
ELECTRICAL ENGINEER:
XXXX
MECHANICAL ENGINEER:
XXXX
LANDSCAPE ARCHITECT:
XXXX
WATER SYSTEM / FIRE PROTECTION SYSTEM:
XXXXt
THIS PLAN IS BASED UPON DATA COMPILED
AND FURNISHED BY OTHERS.
BUILDING AND SAFETY - SUBMITTAL
SHEET NAME
DATE
SCALE
PROJECT
SHEET NUMBER OF SHEETS
C16 - 011
00
ROY E COLBERT
ARCHITECTURE
PLANNING
DESIGN
1997 EAST MAIN STREET
VENTURA, CA 93001
805 / 650 . 9590 PH
805 / 650 . 9589 FX
CALIFORNIA C12050
N.C.A.R.B.
AS SHOWN
This project has been designed by me, or
under my direct supervision.
ISSUE FOR CONSTRUCTION
PLANNING - SUBMITTAL
PRELIMINARY - NOT FOR CONSTRUCTION
DOOR HARDWARE SETS
DESCRIPTIONDOOR SET FINISH REMARKS
CONTINUOUS HINGES
1 PR
35083A
MODEL
VERIFY WHICH DOORS SHALL BE MASTER KEYED PRIOR
TO JOB COMPLETION.
THE TOPS, BOTTOMS AND SIDES OF ALL DOORS SHALL BE
PAINTED AND FINISHED TO MATCH THE DOOR FACE
ALL 'EXIT' DOORS MUST BE OPERABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY, SPECIAL KNOWLEDGE,
OR EFFORT.
6
7
2
3
5
4
ALL DOOR HARDWARE SHALL BE 32D FINISH, UNLESS NOTED
OTHERWISE
1
8
9
10
11
12
EQUIP ONE DOOR PER PAIR TO RECEIVE THE CORBIN-
RUSSWIN #3070 CYLINDER HOUSING WITH #8000 CYLINDER
& 93C1 KEYWAY w/ THE OTHER DOOR TO BE "DOGGED"
INSTALL PEMKO ALUM. SADDLES/THRESHOLDS PER A.D.A.
WHERE NECESSARY TO LIMIT FLOOR DIFFERENTIAL
LCN 4041 SHCUSH CLOSERS TO INCLUDE #18 DROP PLATE,
#3049 SCNS SPRING H HOLD OPEN. SUBMIT SAMPLE.
GENERAL DOOR NOTES
PROVIDE TEMPORARY LOCK CYLINDERS DURING
CONSTRUCTION. DOORS SHALL BE LOCKED AT THE END OF
EACH WORK DAY.
INSTALL SPECIFIED DOOR LOCK CYLINDERS PRIOR TO
JOB COMPLETION. COORDINATE WITH VENTURA COLLEGE.
ALL DOORS SHALL BE PRE-FINISHED AT EITHER SHOP OR
FACTORY
ALL DOOR HARDWARE SHALL COMPLY WITH THE REQUIRE-
MENTS FOR ACCESSIBILITY PER C.B.C., 11B-303, 11B-309.3,
11B-309.4, 11B-404.2.7, 11B-404.2.5, 11B-404.2.8 & 11B-404.2.9.
WHERE UNDERCUT IS NOT SPECIFIED, ALLOW FOR EITHER A
THRESHOLD OR
3
4
" WHERE NO THRESHOLD CONDITION.
QTY. MANUFACTURER
DR-1
STOREFRONT DOORS & FRAME US ALUMINUM (CRL) #11 CLEAR ANODIZED400 MEDIUM STILE
US ALUMINUM (CRL) #11 CLEAR ANODIZED1 EA
1 EA PANIC HARDWARE 9927 VON DUPRIN
1 EA DOOR PULLS M1741028 US ALUMINUM (CRL) #11 CLEAR ANODIZED 10" CENTER
1 EA CLOSER LCN4041 SHCUSH AL (NOTE 12)
CUSTOM FRAME
PR 36" x 83
1
2
" H.M. DRS / NON-RATED / EXIT /
SURFACE MOUNT
1
90 DEG. w/ HOLD OPEN
THRESHOLD 2009_PK PEMKO K: PEM KOTE SKID RESISTANT
(E) PR: 40" x 83
1
2
" TO BE REMOVED / (E) JAMB FRAME TO REMAIN IN PLACE
CONTINUOUS HINGES
1 PR
35083A
DR-2
STOREFRONT DOORS & FRAME US ALUMINUM (CRL) #11 CLEAR ANODIZED400 MEDIUM STILE
US ALUMINUM (CRL) #11 CLEAR ANODIZED1 EA
1 EA PANIC HARDWARE 9927 VON DUPRIN
1 EA PULL M1741028 US ALUMINUM (CRL) #11 CLEAR ANODIZED 10" CENTER
1 EA CLOSER LCN
CUSTOM FRAME
PR 36" x 83
1
2
" H.M. DRS / NON-RATED / EXIT /
SURFACE MOUNT
1
90 DEG. w/ HOLD OPEN
THRESHOLD 2009_PK PEMKO K: PEM KOTE SKID RESISTANT
(E) PR: 40" x 83
1
2
" TO BE REMOVED / (E) JAMB FRAME TO REMAIN IN PLACE
CONTINUOUS HINGES
1 PR
35083A
DR-3
STOREFRONT DOORS & FRAME US ALUMINUM (CRL) #11 CLEAR ANODIZED400 MEDIUM STILE
US ALUMINUM (CRL) #11 CLEAR ANODIZED1 EA
1 EA PANIC HARDWARE 9927 VON DUPRIN
1 EA PULL M1741028 US ALUMINUM (CRL) #11 CLEAR ANODIZED 10" CENTER
1 EA CLOSER LCN
CUSTOM FRAME
PR 36" x 83
1
2
" H.M. DRS / NON-RATED / EXIT /
SURFACE MOUNT
1
90 DEG. w/ HOLD OPEN
THRESHOLD 2009_PK PEMKO K: PEM KOTE SKID RESISTANT
(E) PR: 40" x 83
1
2
" TO BE REMOVED / (E) JAMB FRAME TO REMAIN IN PLACE
CONTINUOUS HINGES
1 PR
35083A
DR-4
STOREFRONT DOORS & FRAME US ALUMINUM (CRL) #11 CLEAR ANODIZED400 MEDIUM STILE
US ALUMINUM (CRL) #11 CLEAR ANODIZED1 EA
1 EA PANIC HARDWARE 9927 VON DUPRIN
1 EA
PULL M1741028 US ALUMINUM (CRL) #11 CLEAR ANODIZED 10" CENTER
1 EA CLOSER LCN
CUSTOM FRAME
PR 36" x 83
1
2
" H.M. DRS / NON-RATED / EXIT /
SURFACE MOUNT
1
90 DEG. w/ HOLD OPEN
THRESHOLD 2009_PK PEMKO K: PEM KOTE SKID RESISTANT
(E) PR: 40" x 83
1
2
" TO BE REMOVED / (E) JAMB FRAME TO REMAIN IN PLACE
1 EA CYLINDER LOCK # 3070 CYLINDER HOUSING
# 8000 CYLINDER
KEYWAY #93C1
CORBIN RUSSWIN INTERCHANGEABLE
NIGHT LATCH FUNCTION
PULL & KEY HEX @ INT'R
1 EA CYLINDER LOCK CORBIN RUSSWIN
1 EA CYLINDER LOCK CORBIN RUSSWIN
1 EA
CYLINDER LOCK CORBIN RUSSWIN
HEAVY DUTY
INTERCHANGEABLE
NIGHT LATCH FUNCTION
PULL & KEY HEX @ INT'R
DR-5
PR 30" x 83
1
2
" H.M. DRS / NON-RATED / EXIT /
(E) PR: 30" x 83
1
2
" DRS TO BE REMOVED / (E) JAMB FRAME TO REMAIN IN PLACE
1 PR H. M. DOORS
B-14 SERIES 1
3
4
" TH.
STEEL STIFFENERSSTEELCRAFT PAINT TO MATCH (E)
BUTT HINGES
4
1
2
" x 4
1
2
" BALL BEARING
STAINLESS STEEL
1 EA PANIC HARDWARE 9927 VON DUPRIN SURFACE MOUNT
1 EA CYLINDER LOCK CORBIN RUSSWIN
1 EA PULL 8105-0 IVES US32D 10" CENTER
1 EA CLOSER LCN L.H. REV DR.: 90 DEG.
w/ HOLD OPEN
R.H. REV DR.: 180 DEG.
w/ HOLD OPEN
DR-6
(N) PR 30" x 83
1
2
" H.M. DRS / NON-RATED / EXIT /
(E) PR: 30" x 83
1
2
" DRS TO BE REMOVED / (E) JAMB FRAME TO REMAIN IN PLACE
1 PR
B-14 SERIES 1
3
4
" TH.
STEELCRAFT PAINT TO MATCH (E)
1
1
2
PR BUTT HINGES
4
1
2
" x 4
1
2
" BALL BEARING
STAINLESS STEEL
1 EA PANIC HARDWARE 9927 VON DUPRIN
1 EA CYLINDER LOCK CORBIN RUSSWIN
1 EA PULL
8105-0 IVES
1 EA CLOSER LCN
STEEL STIFFENERS
SURFACE MOUNT
DR-7
HEAVY DUTY
HEAVY DUTY
(N) PR 30" x 83
1
2
" H.M. DRS / NON-RATED / EXIT /
(E) PR: 30" x 83
1
2
" DRS TO BE REMOVED / (E) JAMB FRAME TO REMAIN IN PLACE
1 PR
B-14 SERIES 1
3
4
" TH.
STEELCRAFT PAINT TO MATCH (E)
BUTT HINGES
4
1
2
" x 4
1
2
" BALL BEARING
STAINLESS STEEL
1 EA PANIC HARDWARE9927 VON DUPRIN
1 EA CYLINDER LOCKCORBIN RUSSWIN
1 EA PULL
STAINLESS STEEL
1 EA CLOSER LCN
STEEL STIFFENERS
SURFACE MOUNT
HEAVY DUTY
AEC ATHLETIC EVENT CENTER
10" CENTER
90 DEG. w/ HOLD OPEN
8105-0 IVES
10" CENTER
626
626
626
626
626
626
STAINLESS STEEL
626
R.H. REV DR.: 90 DEG.
w/ HOLD OPEN
L.H. REV DR.: 180 DEG.
w/ HOLD OPEN
DESCRIPTIONDOOR SET FINISH REMARKSMODELQTY. MANUFACTURER
DR-8
1
1
2
PR
1 EA PANIC HARDWARE 9927 VON DUPRIN
1 EA DOOR PULLS 8105-0 10" CENTER
1 EA CLOSER LCN
SURFACE MOUNT
DR-9
1 EA PANIC HARDWARE 9927 VON DUPRIN
1 EA 10" CENTER
1 EA CLOSER LCN
SURFACE MOUNT
180 DEG. w/ HOLD OPEN
1 EA CYLINDER LOCK CORBIN RUSSWIN INTERCHANGEABLE
NIGHT LATCH FUNCTION
PULL & KEY HEX @ INT'R
1 EA CYLINDER LOCK CORBIN RUSSWIN
C GYMNASIUM
626
626
1 EA
1 EA KICKPLATE 8400 IVES US32D 10" x 28" @ GYM SIDE
1 EA KICKPLATE 8400 IVES US32D 10" x 28" @ GYM SIDE
1 EA KICKPLATE 8400 IVES US32D 10" x 28" @ GYM SIDE
KICKPLATE 8400 IVES US32D 10" x 34" @ GYM SIDE
DOOR PULLS
HAGAR 32D
HAGAR 32D
1 EA KICKPLATE 8400 IVES US32D 10" x 34" @ GYM SIDE
DR-10
1 EA PANIC HARDWARE 9927 VON DUPRIN
1 EA 10" CENTER
1 EA CLOSER LCN
SURFACE MOUNT
1 EA CYLINDER LOCK CORBIN RUSSWIN 626
DOOR PULLS HAGAR 32D
1 EA KICKPLATE 8400 IVES US32D 10" x 34" @ GYM SIDE
DR-11
1 EA PANIC HARDWARE 9927 VON DUPRIN
1 EA 10" CENTER
1 EA CLOSER LCN
SURFACE MOUNT
1 EA CYLINDER LOCK CORBIN RUSSWIN 626
DOOR PULLS HAGAR 32D
1 EA KICKPLATE 8400 IVES US32D 10" x 34" @ GYM SIDE
HARDWARE SCHEDULE
16-011: A-2
8105-0
8105-0
8105-0
# 3070 CYLINDER HOUSING
# 8000 CYLINDER
KEYWAY #93C1
# 3070 CYLINDER HOUSING
# 8000 CYLINDER
KEYWAY #93C1
INTERCHANGEABLE
NIGHT LATCH FUNCTION
PULL & KEY HEX @ INT'R
INTERCHANGEABLE
NIGHT LATCH FUNCTION
PULL & KEY HEX @ INT'R
# 3070 CYLINDER HOUSING
# 8000 CYLINDER
KEYWAY #93C1
# 3070 CYLINDER HOUSING
# 8000 CYLINDER
KEYWAY #93C1
# 3070 CYLINDER HOUSING
# 8000 CYLINDER
KEYWAY #93C1
INTERCHANGEABLE
NIGHT LATCH FUNCTION
PULL & KEY HEX @ INT'R
# 3070 CYLINDER HOUSING
# 8000 CYLINDER
KEYWAY #93C1
INTERCHANGEABLE
NIGHT LATCH FUNCTION
PULL & KEY HEX @ INT'R
US32D
US32D
# 3070 CYLINDER HOUSING
# 8000 CYLINDER
KEYWAY #93C1
INTERCHANGEABLE
NIGHT LATCH FUNCTION
PULL & KEY HEX @ INT'R
INTERCHANGEABLE
NIGHT LATCH FUNCTION
PULL & KEY HEX @ INT'R
# 3070 CYLINDER HOUSING
# 8000 CYLINDER
KEYWAY #93C1
INTERCHANGEABLE
NIGHT LATCH FUNCTION
PULL & KEY HEX @ INT'R
# 3070 CYLINDER HOUSING
# 8000 CYLINDER
KEYWAY #93C1
INTERCHANGEABLE
NIGHT LATCH FUNCTION
PULL & KEY HEX @ INT'R
# 3070 CYLINDER HOUSING
# 8000 CYLINDER
KEYWAY #93C1
4041 SHCUSH AL (NOTE 12)
4041 SHCUSH AL (NOTE 12) AL 689
AL 689
AL 689
4041 SHCUSH AL (NOTE 12)
4041 SHCUSH AL (NOTE 12) AL 689
4041 SHCUSH AL (NOTE 12) AL 689
4041 SHCUSH AL (NOTE 12) AL 689
13
13
13
13
14
H.M. DOOR STIFFENERS: 20 GA. HAT SECTION STEEL THAT SPAN
THE ENTIRE DOOR PANEL / SPACE AT 6-INCHES ON CENTER.
HINGES: 4
1
2
" x 4
1
2
" & 5" x 5", 5 KNUCKLE BALL BEARING STAINLESS
STEEL A511, 630, HEAVY WEIGHT, MATCH (E) CONFIGURATION
AND SPREAD, SUBMIT SAMPLE
(N) PR 36" x 83
1
2
" H.M. DRS / NON-RATED / EXIT /
(E) PR: 36" x 83
1
2
" DRS TO BE REMOVED / (E) JAMB FRAME TO REMAIN IN PLACE
(N) PR 36" x 83
1
2
" H.M. DRS / NON-RATED / EXIT /
(E) PR: 36" x 83
1
2
" DRS TO BE REMOVED / (E) JAMB FRAME TO REMAIN IN PLACE
(N) PR 36" x 83
1
2
" H.M. DRS / NON-RATED / EXIT /
(E) PR: 36" x 83
1
2
" DRS TO BE REMOVED / (E) JAMB FRAME TO REMAIN IN PLACE
4041 SHCUSH AL (NOTE 12) AL 689
4041 SHCUSH AL (NOTE 12) AL 689
(N) PR 36" x 83
1
2
" H.M. DRS / NON-RATED / EXIT /
(E) PR: 36" x 83
1
2
" DRS TO BE REMOVED / (E) JAMB FRAME TO REMAIN IN PLACE
4041 SHCUSH AL (NOTE 12) AL 689
1 PR H.M. DOORS STEELCRAFT (ALLEGION) PAINT TO MATCH (E)B-14 SERIES (14 GA.) STEEL STIFFENERS
BUTT HINGES
4
1
2
" x 4
1
2
" BALL BEARING
STAINLESS STEEL13 HEAVY DUTY
1
1
2
PR
1 PR H.M. DOORS STEELCRAFT (ALLEGION) PAINT TO MATCH (E)B-14 SERIES (14 GA.) STEEL STIFFENERS
BUTT HINGES
4
1
2
" x 4
1
2
" BALL BEARING
STAINLESS STEEL13 HEAVY DUTY
1
1
2
PR
1 PR H.M. DOORS - HALF LITE STEELCRAFT (ALLEGION) PAINT TO MATCH (E)B-14 SERIES (14 GA.) STEEL STIFFENERS
BUTT HINGES 5" x 5" BALL BEARING STAINLESS STEEL13 HEAVY DUTY
1
1
2
PR
1 PR H.M. DOORS STEELCRAFT (ALLEGION) PAINT TO MATCH (E)B-14 SERIES (14 GA.) STEEL STIFFENERS
BUTT HINGES 5" x 5" BALL BEARING STAINLESS STEEL13 HEAVY DUTY
DR-12
1 EA PANIC HARDWARE 9927 VON DUPRIN
1 EA 10" CENTER
1 EA CLOSER LCN
SURFACE MOUNT
1 EA CYLINDER LOCK CORBIN RUSSWIN 626
DOOR PULLS HAGAR 32D
1 EA KICKPLATE 8400 IVES US32D 10" x 34" @ GYM SIDE
8105-0
INTERCHANGEABLE
NIGHT LATCH FUNCTION
PULL & KEY HEX @ INT'R
# 3070 CYLINDER HOUSING
# 8000 CYLINDER
KEYWAY #93C1
(N) PR 36" x 83
1
2
" H.M. DRS / NON-RATED / EXIT /
(E) PR: 36" x 83
1
2
" DRS TO BE REMOVED / (E) JAMB FRAME TO REMAIN IN PLACE
1
1
2
PR
1 PR H.M. DOORS STEELCRAFT (ALLEGION) PAINT TO MATCH (E)B-14 SERIES (14 GA.) STEEL STIFFENERS
BUTT HINGES
4
1
2
" x 4
1
2
" BALL BEARING
STAINLESS STEEL13 HEAVY DUTY
DR-13
1 EA PANIC HARDWARE 9927 VON DUPRIN
1 EA 10" CENTER
1 EA CLOSER LCN
SURFACE MOUNT
1 EA CYLINDER LOCK CORBIN RUSSWIN 626
DOOR PULLS HAGAR 32D
1 EA KICKPLATE 8400 IVES US32D 10" x 34" @ GYM SIDE
8105-0
INTERCHANGEABLE
NIGHT LATCH FUNCTION
PULL & KEY HEX @ INT'R
# 3070 CYLINDER HOUSING
# 8000 CYLINDER
KEYWAY #93C1
(N) PR 36" x 83
1
2
" H.M. DRS / NON-RATED / EXIT /
(E) PR: 36" x 83
1
2
" DRS TO BE REMOVED / (E) JAMB FRAME TO REMAIN IN PLACE
1
1
2
PR
1 PR H.M. DOORS STEELCRAFT (ALLEGION) PAINT TO MATCH (E)B-14 SERIES (14 GA.) STEEL STIFFENERS
BUTT HINGES
4
1
2
" x 4
1
2
" BALL BEARING
STAINLESS STEEL13 HEAVY DUTY
15
H.M. DOOR INTERNAL REINFORCING: 7 GA. HINGE REINFORCING
14 GA. CLOSER REINFORCING, 14 GA. TOP & BTTM RAILS
4041 SHCUSH AL (NOTE 12) AL 689
4041 SHCUSH AL (NOTE 12) AL 689
4041 SHCUSH AL (NOTE 12) AL 689
14 15
14 15
14 15
14 15
14 15
14 15
180 DEG. w/ HOLD OPEN
180 DEG. w/ HOLD OPEN
180 DEG. w/ HOLD OPEN
180 DEG. w/ HOLD OPEN
180 DEG. w/ HOLD OPEN
1
1
2
PR
1
1
2
PR
16
THE HARDWARE FOR ALL DOORS SHALL BE INSTALLED WITH
THE MANUFACTURER'S TEMPLATES. TEMPLATES SHALL BE
SUBMITTED PRIOR TO INSTALLATION.
17
PROVIDE PROTECTIVE MEASURES TO ENSURE THE DOORS AND
HARDWARE WILL BE WITHOUT DAMAGE OR DETERIORATION.
18
THE PERFORMANCE OF DOORS SHALL BE HEAVY DUTY RATED.
19
FINAL APPROVAL OF ALL DOOR AND HARDWARE INSTALLATION
SHALL BE PER INSPECTION BY THE DIRECTOR OF FACILITIES,
MAINTENANCE & OPERATIONS FOR VENTURA COLLEGE.
20
ALL EXPOSED DOOR SURFACES, TOPS, BOTTOMS AND SIDES
SHALL BE FREE OF SCRATCHES AND SERIOUS BLEMISHES.
DOORS SHALL BE INSTALLED IN ACCORDANCE WITH THE STEEL
DOOR INSTITUTE RECOMMENDED INSTRUCTIONS.
21
DR-14
1 EA CLOSER LCN
1 EA CYLINDER LOCK SCHLAGE 626 INTERCHANGEABLE
NIGHT LATCH FUNCTION
PULL & KEY HEX @ INT'R
# ND70J-CO6D RHO HOUSING
# 8000 CYLINDER
KEYWAY #93C1
(N) 36" x 83
1
2
" ALUMINUM STOREFRONT DR / NON-RATED / TINTED GLASS
(E) 36" x 83
1
2
" WOOD DUTCH DR TO BE REMOVED / (E) JAMB FRAME TO REMAIN IN PLACE
1
1
2
PR
1
BUTT HINGES
4
1
2
" x 4
1
2
" BALL BEARING
STAINLESS STEEL13 HEAVY DUTY
4041 SHCUSH AL (NOTE 12) AL 689 180 DEG. w/ HOLD OPEN
ALUMINUM STOREFRONT DOOR US ALUMINUM (CRL) #11 CLEAR ANODIZED400 MEDIUM STILE TINTED GLASS
CORBIN RUSSWIN
14 15
H. M. DOORS 14 15
H. M. DOORS 14 15