+ All Categories
Home > Documents > Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall,...

Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall,...

Date post: 29-Jul-2020
Category:
Upload: others
View: 0 times
Download: 0 times
Share this document with a friend
144
Veritas InfoScale™ 7.0 Release Notes - AIX December 2015
Transcript
Page 1: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Veritas InfoScale™ 7.0Release Notes - AIX

December 2015

Page 2: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Veritas Infoscale Release NotesThe software described in this book is furnished under a license agreement and may be usedonly in accordance with the terms of the agreement.

Product version: 7.0

Document version: 7.0 Rev 2

Page 3: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Chapter 1 About this document ......................................................... 11About this document ..................................................................... 11

Chapter 2 Important release information ........................................ 12

Important release information .......................................................... 12

Chapter 3 About the Veritas InfoScale product suite .................. 13

About the Veritas InfoScale product suite .......................................... 13About Veritas InfoScale Foundation ................................................. 14About Veritas InfoScale Storage ...................................................... 15About Veritas InfoScale Availability .................................................. 15About Veritas InfoScale Enterprise ................................................... 15Components of the Veritas InfoScale product suite .............................. 15

Chapter 4 Licensing Veritas InfoScale ........................................... 17

About Veritas InfoScale product licensing .......................................... 17Registering Veritas InfoScale using product license keys ...................... 18Registering Veritas InfoScale product using keyless licensing ................ 19Updating your product licenses ....................................................... 20Using the vxlicinstupgrade utility .................................................. 21About the VRTSvlic fileset ............................................................. 22

Chapter 5 About Symantec Operations ReadinessTools ................................................................................ 23

About Symantec Operations Readiness Tools .................................... 23

Chapter 6 Changes introduced in 7.0 .............................................. 26

Licensing changes for InfoScale 7.0 ................................................. 26InfoScale Product keys ............................................................ 26The vxlicinstupgrade utility ....................................................... 26

Support for SmartIO caching on SSD devices exported by FSS ............. 27

Contents

Page 4: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Stronger security with 2048 bit key and SHA256 signaturecertificates ............................................................................ 27

Inter ProcessMessaging (IPM) protocol used for secure communicationis not supported ..................................................................... 27

ApplicationHA is not included in the 7.0 Veritas InfoScale productfamily ................................................................................... 28

Changes related to installation and upgrade ...................................... 28Mounting the ISO image .......................................................... 29

Not supported in this release .......................................................... 30Changes related to documents ........................................................ 30

Chapter 7 System requirements ....................................................... 31

System requirements .................................................................... 31Supported AIX operating systems ............................................. 31Storage Foundation for Databases features supported in database

environments .................................................................. 31Storage Foundation memory requirements .................................. 33Supported database software ................................................... 33Hardware compatibility list ........................................................ 33Number of nodes supported ..................................................... 33AIX APARs required for Virtual Memory Management

chunking ........................................................................ 33Required attributes of LUNs for DMP devices ............................... 34

Chapter 8 Fixed Issues ........................................................................ 35

Fixed issues ................................................................................ 35

Chapter 9 Known Issues ..................................................................... 36

Issues related to installation and upgrade .......................................... 36Notify sink resource and generic application resource moves to

OFFLINE|UNKNOWN state after VCS upgrade[3806690] ....................................................................... 37

In an upgraded cluster, security configuration may fail whileimporting VCS_SERVICES file. [3708929] ................................ 38

Switch fencing in enable or disable mode may not take effect ifVCS is not reconfigured [3798127] ....................................... 38

During an upgrade process, the AMF_START or AMF_STOPvariable values may be inconsistent [3763790] ....................... 39

Stopping the installer during an upgrade and then resuming theupgrade might freeze the service groups (2574731) ................ 39

4Contents

Page 5: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

If you have a shared (system)WPAR configured, when you install,upgrade, or uninstall any Symantec product, the filesets inthe WPAR are not synchronized correspondingly(3313690) ....................................................................... 39

NetBackup 6.5 or older version is installed on a VxFS file system(2056282) ....................................................................... 40

The VRTSvxvm fileset fails to install on a few cluster nodesbecause the template file is corrupted (2348780) .................... 40

After a locale change restart the vxconfig daemon (2417547,2116264) ........................................................................ 41

Storage Foundation known issues ................................................... 41Dynamic Multi-Pathing known issues .......................................... 41Veritas Volume Manager known issues ....................................... 43Veritas File System known issues .............................................. 51

Replication known issues ............................................................... 55RVGPrimary agent operation to start replication between the

original Primary and the bunker fails during failback(2036605) ....................................................................... 55

A snapshot volume created on the Secondary, containing a VxFSfile systemmay not mount in read-write mode and performinga read-write mount of the VxFS file systems on the newPrimary after a global clustering site failover may fail[3761497] ....................................................................... 56

In an IPv6-only environment RVG, data volumes or SRL namescannot contain a colon (1672410, 1672417) ........................... 57

vxassist relayout removes the DCM (145413) ............................... 57vradmin functionality may not work after a master switch operation

[2158679] ....................................................................... 57Cannot relayout data volumes in an RVG from concat to

striped-mirror (2129601) .................................................... 58vradmin verifydata operation fails when replicating between

versions 5.1 and 6.0 or later (2360713) ................................. 59vradmin verifydata may report differences in a cross-endian

environment (2834424) ..................................................... 59vradmin verifydata operation fails if the RVG contains a volume

set (2808902) ................................................................. 59Bunker replay does not occur with volume sets (3329970) .............. 60During moderate to heavy I/O, the vradmin verifydata command

may falsely report differences in data (3270067) ..................... 60The vradmin repstatus command does not show that the

SmartSync feature is running [3343141] ................................ 60While vradmin commands are running, vradmind may temporarily

lose heartbeats (3347656, 3724338) .................................... 60

5Contents

Page 6: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Write I/Os on the primary logowner may take a long time tocomplete (2622536) .......................................................... 61

DCM logs on a disassociated layered data volume results inconfiguration changes or CVM node reconfiguration issues(3582509) ....................................................................... 61

After performing a CVM master switch on the secondary node,both rlinks detach (3642855) .............................................. 62

The RVGPrimary agent may fail to bring the application servicegroup online on the new Primary site because of a previousprimary-elect operation not being run or not completingsuccessfully (3761555, 2043831) ........................................ 62

A snapshot volume created on the Secondary, containing a VxFSfile systemmay not mount in read-write mode and performinga read-write mount of the VxFS file systems on the newPrimary after a global clustering site failover may fail(1558257) ....................................................................... 62

Cluster Server known issues ........................................................... 63Operational issues for VCS ...................................................... 64Issues related to the VCS engine ............................................... 65Issues related to the bundled agents .......................................... 71Issues related to the VCS database agents .................................. 76Issues related to the agent framework ........................................ 78Cluster Server agents for Volume Replicator known issues ............. 81Issues related to Intelligent Monitoring Framework (IMF) ................ 82Issues related to global clusters ................................................. 85Issues related to the Cluster Manager (Java Console) .................... 85VCS Cluster Configuration wizard issues ..................................... 86LLT known issues ................................................................... 86I/O fencing known issues ......................................................... 86GAB known issues ................................................................. 94

Storage Foundation and High Availability known issues ........................ 95Cache area is lost after a disk failure (3158482) ............................ 95In an IPv6 environment, db2icrt and db2idrop commands return

a segmentation fault error during instance creation andinstance removal (1602444) .............................................. 96

Oracle 11gR1 may not work on pure IPv6 environment(1819585) ....................................................................... 96

Not all the objects are visible in the VOM GUI (1821803) ................ 97An error message is received when you perform off-host clone

for RAC and the off-host node is not part of the CVM cluster(1834860) ....................................................................... 97

6Contents

Page 7: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

A volume's placement class tags are not visible in the VeritasEnterprise Administrator GUI when creating a SmartTierplacement policy (1880081) ................................................ 98

Upgrading operating system Technology Levels along with StorageFoundation using an alternate disk fails (2162945) .................. 98

Storage Foundation Cluster File System High Availability knownissues .................................................................................. 98Write back cache is not supported on the cluster in FSS scenario

[3723701] ....................................................................... 99CVMVOLDg agent is not going into the FAULTED state.

[3771283] ....................................................................... 99CFS commands might hang when run by non-root

(3038283) ....................................................................... 99Inode access and modification times are not getting updated on

the primary node when a file owned by the primary node isaccessed from a secondary node (2170318) ........................ 100

The fsappadm subfilemove command moves all extents of a file(3258678) ..................................................................... 100

Certain I/O errors during clone deletion may lead to system panic.(3331273) ..................................................................... 100

Panic due to null pointer de-reference in vx_bmap_lookup()(3038285) ..................................................................... 101

In a CFS cluster, that has multi-volume file system of a small size,the fsadm operation may hang (3348520) ............................ 101

Storage Foundation for Oracle RAC known issues ............................. 101Oracle RAC known issues ...................................................... 101Storage Foundation Oracle RAC issues .................................... 102

Storage Foundation for Databases (SFDB) tools known issues ............ 108Sometimes SFDB may report the following error message: SFDB

remote or privileged command error (2869262) .................... 108SFDB commands do not work in IPV6 environment

(2619958) ..................................................................... 109The database clone operation using the vxsfadm -o clone(1M)

command fails (3313715) ................................................. 109In an off-host scenario, a clone operation may fail with an error

message (3313572) ........................................................ 109When you attempt to move all the extents of a table, the

dbdst_obj_move(1M) command fails with an error(3260289) ..................................................................... 110

Attempt to use SmartTier commands fails (2332973) ................... 110Attempt to use certain names for tiers results in error

(2581390) ..................................................................... 110

7Contents

Page 8: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Clone operation failure might leave clone database in unexpectedstate (2512664) .............................................................. 111

Clone command fails if PFILE entries have their values spreadacross multiple lines (2844247) ......................................... 111

Clone fails with error "ORA-01513: invalid current time returnedby operating system" with Oracle 11.2.0.3 (2804452) ............. 112

Data population fails after datafile corruption, rollback, and restoreof offline checkpoint (2869259) .......................................... 112

FileSnap detail listing does not display the details of a particularsnap (2846382) .............................................................. 112

Flashsnap clone fails under some unusual archivelog configurationon RAC (2846399) .......................................................... 113

Database StorageCheckpoints created by using dbed_ckptcreatemay not be visible after upgrading to 7.0 (2626248) ............... 113

Cloning of a container database may fail after a reverse resynccommit operation is performed (3509778) ............................ 114

If one of the PDBs is in the read-write restricted state, then cloningof a CDB fails (3516634) ................................................. 114

Cloning of a CDB fails for point-in-time copies when one of thePDBs is in the read-only mode (3513432) ........................... 115

If a CDB has a tablespace in the read-only mode, then the cloningfails (3512370) ............................................................... 115

If any SFDB installation prior to 6.2 with authentication setup isupgraded to 7.0, the commands fail with an error (3644030)................................................................................... 115

Chapter 10 Software Limitations ....................................................... 117

Storage Foundation software limitations .......................................... 117Dynamic Multi-Pathing software limitations ................................. 117Veritas Volume Manager software limitations .............................. 119Veritas File System software limitations ..................................... 121SmartIO software limitations ................................................... 122

Replication software limitations ...................................................... 123VVR Replication in a shared environment .................................. 123VVR IPv6 software limitations .................................................. 123VVR support for replicating across Storage Foundation

versions ........................................................................ 123Cluster Server software limitations ................................................. 124

Limitations related to bundled agents ........................................ 124Limitations related to VCS engine ............................................ 126Cluster configuration wizard limitations ..................................... 127Limitations related to IMF ....................................................... 127

8Contents

Page 9: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Limitations related to the VCS database agents .......................... 127Systems in a cluster must have same system locale setting ........... 128Limitations with DiskGroupSnap agent [1919329] ........................ 128Virtualizing shared storage using VIO servers and client

partitions ....................................................................... 128Cluster Manager (Java console) limitations ................................ 130The operating system does not distinguish between IPv4 and IPv6

packet counts ................................................................ 131A service group that runs inside of aWPARmay not fail over when

its network connection is lost ............................................. 131Limitations related to I/O fencing .............................................. 131Limitations related to global clusters ........................................ 133Clusters must run on VCS 6.0.5 and later to be able to

communicate after upgrading to 2048 bit key and SHA256signature certificates [3812313] ......................................... 134

Storage Foundation Cluster File System High Availability softwarelimitations ............................................................................ 134cfsmntadm command does not verify the mount options

(2078634) ..................................................................... 134Upgrade of secure clusters not supported using native operating

system tools .................................................................. 134Stale SCSI-3 PR keys remain on disk after stopping the cluster

and deporting the disk group ............................................. 135Unsupported FSS scenarios ................................................... 135

Storage Foundation for Oracle RAC software limitations ..................... 135Supportability constraints for normal or high redundancy ASM disk

groups with CVM I/O shipping and FSS (3600155) ................ 135Limitations of CSSD agent ...................................................... 135Oracle Clusterware/Grid Infrastructure installation fails if the cluster

name exceeds 14 characters ............................................ 136Policy-managed databases not supported by CRSResource

agent ........................................................................... 136Health checks may fail on clusters that have more than 10

nodes ........................................................................... 136Cached ODM not supported in Veritas Infoscale

environments ................................................................. 136Storage Foundation for Databases (SFDB) tools software

limitations ............................................................................ 136Parallel execution of vxsfadm is not supported (2515442) ............. 137Creating point-in-time copies during database structural changes

is not supported (2496178) ............................................... 137Oracle Data Guard in an Oracle RAC environment ...................... 137

9Contents

Page 10: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Chapter 11 Documentation ................................................................. 138

Veritas InfoScale documentation .................................................... 138Documentation set ..................................................................... 138

Index .................................................................................................................. 144

10Contents

Page 11: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

About this documentThis chapter includes the following topics:

■ About this document

About this documentThis document provides important information about Veritas Infoscale version 7.0for AIX. Review this entire document before you install or upgrade Veritas Infoscale.

This is "Document version: 7.0 Rev 2" of the Veritas Infoscale Release Notes.Before you start, make sure that you are using the latest version of this guide. Thelatest product documentation is available on the Symantec website at:

https://sort.veritas.com/documents

1Chapter

Page 12: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Important releaseinformation

This chapter includes the following topics:

■ Important release information

Important release informationReview the Release notes for the latest information before you install the product.

Review the current compatibility lists to confirm the compatibility of your hardwareand software:

■ For important updates regarding this release, review the Late-Breaking NewsTechNote on the Symantec Technical Support website:http://www.veritas.com/docs/000025342

■ For the latest patches available for this release, go to:https://sort.veritas.com/

■ The hardware compatibility list contains information about supported hardwareand is updated regularly. For the latest information on supported hardware, visitthe following URL:http://www.veritas.com/docs/000025352

■ The software compatibility list summarizes each Veritas Infoscale product stackand the product features, operating system versions, and third-party productsit supports. For the latest information on supported software, visit the followingURL:http://www.veritas.com/docs/000025344

2Chapter

Page 13: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

About the VeritasInfoScale product suite

This chapter includes the following topics:

■ About the Veritas InfoScale product suite

■ About Veritas InfoScale Foundation

■ About Veritas InfoScale Storage

■ About Veritas InfoScale Availability

■ About Veritas InfoScale Enterprise

■ Components of the Veritas InfoScale product suite

About the Veritas InfoScale product suiteThe Veritas InfoScale product suite addresses enterprise IT service continuityneeds. It draws on Veritas’ long heritage of world-class availability and storagemanagement solutions to help IT teams in realizing ever more reliable operationsand better protected information across their physical, virtual, and cloudinfrastructures. It provides resiliency and software defined storage for critical servicesacross the datacenter infrastructure. It realizes better Return on Investment (ROI)and unlocks high performance by integrating next-generation storage technologies.The solution provides high availability and disaster recovery for complex multi-tieredapplications across any distance. Management operations for Veritas InfoScale areenabled through a single, easy-to-use, web-based graphical interface, VeritasInfoScale Operations Manager.

The Veritas InfoScale product suite offers the following products:

■ Veritas InfoScale Foundation

3Chapter

Page 14: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

■ Veritas InfoScale Storage

■ Veritas InfoScale Availability

■ Veritas InfoScale Enterprise

About Veritas InfoScale FoundationVeritas InfoScale™ Foundation is specifically designed for enterprise edge-tier,departmental, and test/development systems. InfoScale Foundation combines theindustry-leading File System and Volume Manager technology, and delivers acomplete solution for heterogeneous online storage management while increasingstorage utilization and enhancing storage I/O path availability.

Storage features included in InfoScale Foundation products are listed below:

■ No restriction on number of Volumes or File Systems being managed

■ Veritas InfoScale Operations Manager Support

■ 1-256 TB File System

■ Device names using Array Volume IDs

■ Dirty region logging

■ Dynamic LUN expansion

■ Dynamic Multi-pathing

■ Enclosure based naming

■ iSCSI device support

■ Keyless licensing

■ Online file system defragmentation

■ Online file system grow & shrink

■ Online relayout

■ Online volume grow & shrink

Storage features included in InfoScale Storage and Enterprise products, but notincluded in the InfoScale Foundation product are listed below:

■ Hot-relocation

■ Remote mirrors for campus clusters

■ SCSI-3 based I/O Fencing

■ SmartMove

14About the Veritas InfoScale product suiteAbout Veritas InfoScale Foundation

Page 15: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

■ Split-mirror snapshot

■ Thin storage reclamation

■ Flexible Storage Sharing

About Veritas InfoScale StorageVeritas InfoScale™Storage enables organizations to provision andmanage storageindependently of hardware types or locations. InfoScale Storage delivers predictableQuality-of-Service by identifying and optimizing critical workloads. InfoScale Storageincreases storage agility enabling you to work with and manage multiple types ofstorage to achieve better ROI without compromising on performance and flexibility.

About Veritas InfoScale AvailabilityVeritas InfoScale™ Availability helps keep organizations’ information available andcritical business services up and running with a robust software-defined approach.Organizations can innovate and gain cost benefits of physical and virtual acrosscommodity server deployments. Maximum IT service continuity is ensured at alltimes, moving resiliency from the infrastructure layer to the application layer.

About Veritas InfoScale EnterpriseVeritas InfoScale™ Enterprise addresses enterprise IT service continuity needs. Itprovides resiliency and software defined storage for critical services across yourdatacenter infrastructure. Realize better ROI and unlock high performance byintegrating next-generation storage technologies. The solution provides highavailability and disaster recovery for complex multi-tiered applications across anydistance in physical and virtual environments.

Components of the Veritas InfoScale product suiteEach new InfoScale product consists of one or more components. Each componentwithin a product offers a unique capability that you can configure for use in yourenvironment.

Table 3-1 lists the components of each Veritas InfoScale product.

15About the Veritas InfoScale product suiteAbout Veritas InfoScale Storage

Page 16: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Table 3-1 Veritas InfoScale product suite

ComponentsDescriptionProduct

Storage Foundation (SF)Standard (entry-levelfeatures)

Veritas InfoScale™ Foundationdelivers a comprehensive solution forheterogeneous online storagemanagement while increasing storageutilization and enhancing storage I/Opath availability.

Veritas InfoScale™Foundation

Storage Foundation (SF)Enterprise includingReplication

Storage FoundationCluster File System(SFCFS)

Veritas InfoScale™ Storage enablesorganizations to provision andmanagestorage independently of hardwaretypes or locations while deliveringpredictable Quality-of-Service, higherperformance, and betterReturn-on-Investment.

Veritas InfoScale™Storage

Cluster Server (VCS)including HA/DR

Veritas InfoScale™ Availability helpskeep an organization’s information andcritical business services up andrunning on premise and across globallydispersed data centers.

Veritas InfoScale™Availability

Cluster Server (VCS)including HA/DR

Storage Foundation (SF)Enterprise includingReplication

Storage Foundation andHigh Availability (SFHA)

Storage FoundationCluster File System HighAvailability (SFCFSHA)

Storage Foundation forOracle RAC (SF OracleRAC)

Veritas InfoScale™ Enterpriseaddresses enterprise IT servicecontinuity needs. It provides resiliencyand software defined storage forcritical services across your datacenterinfrastructure.

Veritas InfoScale™Enterprise

16About the Veritas InfoScale product suiteComponents of the Veritas InfoScale product suite

Page 17: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Licensing VeritasInfoScale

This chapter includes the following topics:

■ About Veritas InfoScale product licensing

■ Registering Veritas InfoScale using product license keys

■ Registering Veritas InfoScale product using keyless licensing

■ Updating your product licenses

■ Using the vxlicinstupgrade utility

■ About the VRTSvlic fileset

About Veritas InfoScale product licensingYou must obtain a license to install and use Veritas InfoScale products.

You can choose one of the following licensing methods when you install a product:

■ Install with a license key for the productWhen you purchase a Veritas InfoScale product, you receive a License Keycertificate. The certificate specifies the product keys and the number of productlicenses purchased.See “Registering Veritas InfoScale using product license keys” on page 18.

■ Install without a license key (keyless licensing)Installation without a license does not eliminate the need to obtain a license.The administrator and company representatives must ensure that a server orcluster is entitled to the license level for the products installed. Symantec reservesthe right to ensure entitlement and compliance through auditing.

4Chapter

Page 18: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

See “Registering Veritas InfoScale product using keyless licensing” on page 19.

If you encounter problems while licensing this product, visit the Veritas LicensingPortal:

https://www.veritas.com/licensing/process/activate

Registering Veritas InfoScale using productlicense keys

You can register your product license key in the following ways:

The installer automatically registers the license at the time ofinstallation or upgrade.

■ You can register your license keys during the installation process.During the installation, you will get the following prompt:

1) Enter a valid license key2) Enable keyless licensing and complete system licensing later

How would you like to license the systems? [1-2,q] (2)

Enter 1 to register your license key.■ You can also register your license keys using the installer menu.

Run the following command:

./installer

Select the L) License a Product option in the installer menu.

Using theinstaller

18Licensing Veritas InfoScaleRegistering Veritas InfoScale using product license keys

Page 19: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

If you are performing a fresh installation, run the following commandson each node:

# cd /opt/VRTS/bin

# ./vxlicinst -k license key

# vxdctl license init

If you are performing an upgrade, run the following commands oneach node:

# cd /opt/VRTS/bin

# ./vxlicinstupgrade -k license key

For more information:

See “Using the vxlicinstupgrade utility” on page 21.

Manual

Even though other products are included on the enclosed software discs, you canonly use the Veritas InfoScale software products for which you have purchased alicense.

Registering Veritas InfoScale product usingkeyless licensing

The keyless licensing method uses product levels to determine the Veritas InfoScaleproducts and functionality that are licensed.

You can register a Veritas InfoScale product in the following ways:

■ Run the following command:

./installer

The installer automatically registers the license at the timeof installation or upgrade.

■ You can also register your license keys using the installermenu.Run the following command:

./installer

Select the L) License a Product option in the installer menu.

Using the installer

19Licensing Veritas InfoScaleRegistering Veritas InfoScale product using keyless licensing

Page 20: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Perform the following steps after installation or upgrade:

1 Change your current working directory:

# export PATH=$PATH:/opt/VRTSvlic/bin

2 View the possible settings for the product level:

# vxkeyless displayall

3 Register the desired product:

# vxkeyless set prod_levels

where prod_levels is a comma-separated list of keywords.The keywords are the product levels as shown by the outputof step 2.

Manual

Warning:Within 60 days of choosing this option, you must install a valid licensekey corresponding to the license level entitled, or continue with keyless licensingby managing the systems with Veritas InfoScale Operation Manager. If you fail tocomply with the above terms, continuing to use the Veritas InfoScale product is aviolation of your End User License Agreement, and results in warning messages.

For more information about keyless licensing, see the following URL:

http://www.veritas.com/community/blogs/introducing-keyless-feature-enablement-storage-foundation-ha-51

For more information to use keyless licensing and to download the Veritas InfoScaleOperation Manager, see the following URL:

https://www.veritas.com/product/storage-management/infoscale-operations-manager

Updating your product licensesAt any time, you can update your product licenses in any of the following ways:

Perform the following steps:

# export PATH=$PATH:/opt/VRTSvlic/bin# vxkeyless set prod_levels

Move from one product toanother

20Licensing Veritas InfoScaleUpdating your product licenses

Page 21: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

You will need to remove the keyless licenses by using theNONE keyword.

Note: Clearing the keys disables the Veritas InfoScaleproducts until you install a new key or set a new product level.

# vxkeyless [-q] set NONE

Register a Veritas InfoScale product using a license key:

See “Registering Veritas InfoScale using product license keys”on page 18.

Move from keyless licensingto key-based licensing

Using the vxlicinstupgrade utilityThe vxlicinstupgrade utility enables you to perform the following tasks:

■ Upgrade to another Veritas InfoScale product

■ Update a temporary license to a permanent license

■ Manage co-existence of multiple licenses

On executing the vxlicinstupgrade utility, the following checks are done:

■ If the current license key is keyless or user-defined and if the user is trying toinstall the keyless or user defined key of the same product.Example: If the 7.0 Foundation Keyless license key is already installed on asystem and the user tries to install another 7.0 Foundation Keyless license key,then vxlicinstupgrade utility shows an error message:

vxlicinstupgrade WARNING: The input License key and Installed key

are same.

■ If the current key is keyless and the newly entered license key is user-definedof the same productExample: If the 7.0 Foundation Keyless license key is already installed on asystem and the user tries to install 7.0 Foundation user-defined license, thenthe vxlicinstupgrade utility installs the new licenses at /etc/vx/licenses/licand all the 7.0 Foundation Keyless keys are deleted and backed up at/var/vx/licenses/lic<date-timestamp>.

■ If the current key is of higher version and the user tries to install a lower versionlicense key.Example: If the 7.0 Enterprise license key is already installed on a system andthe user tries to install the 6.0 SFSTD license key, then the vxlicinstupgrade

utility shows an error message:

21Licensing Veritas InfoScaleUsing the vxlicinstupgrade utility

Page 22: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

vxlicinstupgrade WARNING: The input License key is lower than the

Installed key.

■ If the current key is of a lower version and the user tries to install a higher versionlicense key.Example: If 6.0 SFSTD license key is already installed on a system and the usertries to install 7.0 Storage license key, then the vxlicinstupgrade utility installsthe new licenses at /etc/vx/licenses/lic and all the 6.0 SFSTD keys aredeleted and backed up at /var/vx/licenses/lic<date-timestamp>.

■ Supported Co-existence scenarios:

■ InfoScale Foundation and InfoScale Availability

■ InfoScale Storage and InfoScale Availability

Example: If the 7.0 Foundation or 7.0 Storage license key is already installed andthe user tries to install 7.0 Availability license key or vice -versa, then thevxlicinstupgrade utility installs the new licenses and both the keys are preservedat /etc/vx/licenses/lic.

Note:When registering license keys manually during upgrade, you have to use thevxlicinstupgrade command. When registering keys using the installer script, thesame procedures are performed automatically.

About the VRTSvlic filesetThe VRTSvlic fileset enables product licensing. After the VRTSvlic is installed, thefollowing commands and their manual pages are available on the system:

Installs a license key for a Veritas InfoScale product

See the vxlicinst(1m) manual page

vxlicinst

Upgrades your license key when you have a product or older licensealready present on the system.

See the vxlicinstupgrade(1m) manual page

vxlicinstupgrade

Displays the currently installed licensesvxlicrep

Retrieves the features and their descriptions that are encoded in alicense key

vxlictest

22Licensing Veritas InfoScaleAbout the VRTSvlic fileset

Page 23: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

About SymantecOperations ReadinessTools

This chapter includes the following topics:

■ About Symantec Operations Readiness Tools

About Symantec Operations Readiness ToolsSymantec Operations Readiness Tools (SORT) is a website that automates andsimplifies some of themost time-consuming administrative tasks. It helps you identifyrisks in your datacenters and improve operational efficiency, enabling you to managethe complexity that is associated with datacenter architectures and scale.

Table 5-1 lists three major datacenter tasks and the SORT tools that can help youaccomplish them.

5Chapter

Page 24: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Table 5-1 Datacenter tasks and the SORT tools

SORT toolsTask

■ Installation and Upgrade checklistsDisplay system requirements including memory, diskspace, and architecture.

■ Installation and Upgrade custom reportsCreate reports that determine if you're ready to installor upgrade a Veritas InfoScale product.

■ Array-specific Module FinderList the latest Array Support Libraries (ASLs) and ArrayPolicy Modules (APMs) for UNIX servers, and DeviceDriver Installers (DDIs) and Device Discovery Layers(DDLs) for Windows servers.

■ High Availability Agents tableFind and download the agents for applications,databases, replication, and Symantec partners.

Prepare for installations andupgrades

■ Patch notificationsReceive automatic email notifications about patchupdates. (Sign in required.)

■ Risk Assessment check listsDisplay configuration recommendations based on yourVeritas InfoScale product and platform.

■ Risk Assessment custom reportsCreate reports that analyze your system and give yourecommendations about system availability, storageuse, performance, and best practices.

■ Error code descriptions and solutionsDisplay detailed information on thousands of errorcodes.

Identify risks and getserver-specificrecommendations

24About Symantec Operations Readiness ToolsAbout Symantec Operations Readiness Tools

Page 25: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Table 5-1 Datacenter tasks and the SORT tools (continued)

SORT toolsTask

■ Patch FinderList and download patches for your Veritas InfoScaleenterprise products.

■ License/Deployment custom reportsCreate custom reports that list your installed VeritasInfoScale products and license keys. Display licensesby product, platform, server tier, and system.

■ Symantec Performance Value Unit (SPVU) CalculatorUse the calculator to assist you with the pricing metertransition.

■ DocumentationList and download Veritas InfoScale productdocumentation, includingmanual pages, product guides,and support articles.

■ Related linksDisplay links to Veritas InfoScale product support,forums, customer care, and vendor information on asingle page.

Improve efficiency

SORT is available at no additional charge.

To access SORT, go to:

https://sort.symantec.com

25About Symantec Operations Readiness ToolsAbout Symantec Operations Readiness Tools

Page 26: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Changes introduced in 7.0This chapter includes the following topics:

■ Licensing changes for InfoScale 7.0

■ Support for SmartIO caching on SSD devices exported by FSS

■ Stronger security with 2048 bit key and SHA256 signature certificates

■ Inter Process Messaging (IPM) protocol used for secure communication is notsupported

■ ApplicationHA is not included in the 7.0 Veritas InfoScale product family

■ Changes related to installation and upgrade

■ Not supported in this release

■ Changes related to documents

Licensing changes for InfoScale 7.0The following sections describe the licensing changes in InfoScale

InfoScale Product keysThere are four new license keys that relate to the new InfoScale products. Eachlicenses a new range of functionality that is described in the product summaries.

The vxlicinstupgrade utilityIf you are using AIX, Solaris and Linux platforms, you can license your productusing the installer script. If you used to register keys manually at the command line

6Chapter

Page 27: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

using the vxlicinst binary, you need to use the vxlicinstupgrade binary instead inthe following two circumstances:

■ Upgrading from 6.0 or later

■ Adding a new license when you transition a smaller product to a larger product

For more information, See “Using the vxlicinstupgrade utility” on page 21.

Support for SmartIO caching on SSD devicesexported by FSS

The SmartIO feature in Veritas InfoScale Foundation, Veritas InfoScale Storageand Veritas InfoScale Enterprise products supports the use of SSD devices exportedby FSS to provide caching services for applications running on VxVM volumes andVxFS file system. In this scenario, Flexible Storage Sharing (FSS) exports SSDsfrom nodes that have a local SSD. FSS then creates a pool of the exported SSDsin the cluster. From this shared pool, a cache area is created for those nodes inthe cluster that do not have local SSDs. Each cache area is accessible only to thatparticular node for which it is created. The cache area can be a VxVM cache areaor a VxFS cache area. The cache areas can be enabled to support warm orpersistent caching across reboots.

For more information, see Veritas InfoScale Solutions 7.0 SmartIO for Solid-StateDrives Solutions Guide.

Stronger security with 2048 bit key and SHA256signature certificates

Stronger security with 2048 bit key and SHA256 signature certificates VCS in VeritasInfoScale Availability 7.0 uses 2048 bit key and SHA256 signature certificates. Thevcsauthserver will generate certificates with 2048 bit key and SHA256 signature.The enhancement provides stronger security to VCS users. All the certificates willbe updated by default on upgrading to VCS 7.0.

Inter Process Messaging (IPM) protocol used forsecure communication is not supported

From 7.0.1, for CP server and InfoScale Availability clusters, HTTPS is the onlysupported communication protocol and IPM protocol is not supported. If you upgradeCPS server with IPM-based CP server configured, reconfigure CP server. If you

27Changes introduced in 7.0Support for SmartIO caching on SSD devices exported by FSS

Page 28: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

want to upgrade the application clusters that use CP server based fencing to version6.1 and later, make sure that VCS or SFHA is upgraded to version 6.1 and laterfirst.

Note: The steps to configure CP server in Cluster Server Administrator's Guideand Cluster Server Configuration and Upgrade Guide might not work because ofthe disablement of the IPM based communication between CP servers and client.

ApplicationHA is not included in the 7.0 VeritasInfoScale product family

ApplicationHA is a standalone product and is not included in Veritas InfoScaleproduct family. You can use any earlier version.

Changes related to installation and upgradeThe following changes are introduced to the installation and upgrading of 7.0 VeritasInfoscale:

■ In 7.0, the following new products are supported:Veritas InfoScale FoundationVeritas InfoScale StorageVeritas InfoScale AvailabilityVeritas InfoScale EnterpriseThe following old products are regarded as components and are converted tonew products during the upgrade:Symantec Storage Foundation (SF)Symantec Cluster Server (VCS)Symantec Storage Foundation and High Availability (SFHA)Symantec Storage Foundation Cluster File System (SFCFS)Symantec Storage Foundation Cluster File System and High Availability(SFCFSHA)Symantec Storage Foundation for Oracle RAC (SF Oracle RAC)The following old products are now part of the SF component and not offeredas separate components.Symantec Dynamic Multi-Pathing (DMP) standaloneVeritas Volume Manager (VxVM)Veritas File System (VxFS)For more information, See “Components of the Veritas InfoScale product suite”on page 15.

28Changes introduced in 7.0ApplicationHA is not included in the 7.0 Veritas InfoScale product family

Page 29: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

■ All packages are installed at the time of installation irrespective of the product.Also, the installation of packages is no longer categorized as recommended,minimum or all.The installation script installer installs the packages. Component installationscripts, such as installvcs, are no longer supported.

■ Theinstall<prod><version> script, for example, installsf70 is no longeravailable under the /opt/VRTS/install/ directory after an installation orupgrade.

■ Installation of two products is not supported, Veritas InfoScale Enterprise willbe installed to include Veritas InfoScale Storage and Veritas InfoScale Availabilityon all the systems.For more information, See “Components of the Veritas InfoScale product suite”on page 15.

■ For 7.0, the new release image file names are as follows:Veritas_InfoScale_7.0_AIX.tar.gzVeritas_InfoScale_7.0_AIX.isoTo install the product for your platform, you can either expand the .tar.gz or .zipfile or mount the .iso file. Note that the content of the .iso file and archive filesare identical.To mount the .iso file on your platform, See “Mounting the ISO image”on page 29.

Mounting the ISO imageAn ISO file is a disc image that must be mounted to a virtual drive for use. You musthave superuser (root) privileges to mount the Veritas InfoScale ISO image.

To mount the ISO image

1 Log in as superuser on a system where you want to install Veritas InfoScale.

2 Create a loopback device to which you can bind the ISO image file:

# mkdev -c loopback -s node -t loopback

loop0 Available

3 Bind the ISO image to the loopback device and mount the device:

# loopmount -i <ISO_image_path> -l loop0 \

-o "-V cdrfs -o ro" -m /mnt

Where <ISO_image_path> is the complete path to the ISO image

29Changes introduced in 7.0Changes related to installation and upgrade

Page 30: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Not supported in this releaseThe following features are not supported in this release but they may be supportedin a future release:

■ Rolling Upgrade and Phased Upgrade

■ Deployment Server

■ -makeresponsefile option for installer

Note: You can use the response file that is created by operating the installer.

The following features will not be supported by the Veritas InfoScale products:

■ Web-based installation

■ Oracle RAC 10g Release 2 is not supported in Storage Foundation for OracleRAC.

Changes related to documentsThe following changes have been introduced to the documents in 7.0:

■ The look-and-feel of the documents reflect the new Veritas brand.

■ This release introduces a single Release Notes and Installation Guide for thenew Veritas InfoScale products.

■ The Release Notes and Installation Guide documents for each component aredeprecated.

■ This release introduces configuration and upgrade guides for each VeritasInfoScale component.

■ The software image has an updated document directory structure to reflect theproduct changes.

■ The documents that were titled Storage Foundation and High AvailabilitySolutions are renamed to Veritas Infoscale. The file names for these documentsare changed as well.

■ The ApplicationHA and Symantec High Availability Console documents aremoved online.

For more information, See “Documentation” on page 138.

30Changes introduced in 7.0Not supported in this release

Page 31: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

System requirementsThis chapter includes the following topics:

■ System requirements

System requirements

Supported AIX operating systemsFor current updates, visit the Symantec Operations Readiness Tools Installationand Upgrade page: https://sort.symantec.com/land/install_and_upgrade.

Table 7-1 shows the supported operating systems for this release.

Table 7-1 Supported operating systems

ChipsetsLevelsOperatingsystems

Power 5, Power 6, Power 7, or Power 8TL2, or TL3AIX 7.1

Power 5, Power 6, Power 7, or Power 8TL8, or TL9AIX 6.1

For the SF Oracle RAC component, all nodes in the cluster need to have the sameoperating system version and update level.

Storage Foundation for Databases features supported in databaseenvironments

Storage Foundation for Databases (SFDB) product features are supported for thefollowing database environments:

7Chapter

Page 32: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Table 7-2 SFDB features supported in database environments

SybaseOracleRAC

OracleDB2Storage Foundation feature

NoYesYesNoOracle Disk Manager

NoNoYesNoCached Oracle Disk Manager

YesYesYesYesQuick I/O

YesYesYesYesCached Quick I/O

YesYesYesYesConcurrent I/O

YesYesYesYesStorage Checkpoints

YesYesYesYesFlashsnap

YesYesYesYesSmartTier

NoYesYesYesDatabase Storage Checkpoints

Note: Requires Enterprise license

NoYesYesYesDatabase Flashsnap

Note: Requires Enterprise license

NoYesYesNoSmartTier for Oracle

Note: Requires Enterprise license

Notes:

■ SmartTier is an expanded and renamed version of Dynamic Storage Tiering(DST).

■ Storage Foundation for Databases (SFDB) tools Database Storage Checkpoint,Database Flashsnap, and SmartTier for Oracle are supported with an Enterpriseproduct license.

For themost current information on Storage Foundation products and single instanceOracle versions supported, see:

https://www.veritas.com/support/en_US/article.DOC4039

Review the current Oracle documentation to confirm the compatibility of yourhardware and software.

32System requirementsSystem requirements

Page 33: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Storage Foundation memory requirementsSymantec recommends 2 GB of memory over the minimum requirement for theoperating system.

Supported database softwareFor the latest information on supported database, see the followingTechNote:https://www.veritas.com/support/en_US/article.DOC4039

Additionally, see the following Oracle support site for information on patches thatmay be required by Oracle for each release.https://support.oracle.com

Hardware compatibility listThe compatibility list contains information about supported hardware and is updatedregularly. For the latest information on supported hardware go to the following URL:

https://www.veritas.com/support/en_US/article.TECH230646

Before installing or upgrading Veritas Cluster Server, review the current compatibilitylist to confirm the compatibility of your hardware and software.

For information on specific HA setup requirements, see the Veritas Cluster ServerInstallation Guide.

Number of nodes supportedSFHA Solutions support cluster configurations with up to 64 nodes.

AIX APARs required for Virtual Memory Management chunkingTable 7-3 lists the AIX APARs that you must install to use the Virtual MemoryManagement (VMM) chunking feature, as well as the default value for thethrpgio_npages and thrpgio_inval APAR tunables.

Table 7-3 AIX APARs required for Virtual Memory Management chunking

Default APAR tunablevalue

Required APARsOperating System

0

1024

IV16685

IV18846

AIX 6 TL8

0

1024

IV17138

IV19372

AIX 7 TL2

33System requirementsSystem requirements

Page 34: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

You must set dchunk_enable=1 to enable Veritas File System (VxFS) to utilize theVMM chunking feature rather than the VxFS internal chunking feature.

For information about setting the dchunk_enable tunable, see the vxtunefs(1M)manual page.

Required attributes of LUNs for DMP devicesWhen the reserve_policy=single_path and reserve_lock=yes, the SCSI-2reserve may be placed on the device, which affects I/O load balancing andperformance. To prevent the impact to load balancing and performance, set thereserve_policy=no_reserve and reserve_lock=no for the devices that aremanaged by DMP.

These settings are also required for a cluster set-up.

Set the following attributes for LUNs

1 Set the following attributes:

■ If the path has the reserve_policy attribute set, change thereserve_policy attribute to no_reserve for all the paths.

# lsattr -E1 hdisk557 | grep res

reserve_policy single_path

Reserve Policy True

# chdev -l hdisk557 -a reserve_policy=no_reserve -P

hdisk557 changed

■ If the path has the reserve_lock attribute set, change the reserve_lock

attribute to no.

# lsattr -E1 hdisk558 | grep reserve_lock

reserve_lock yes

Reserve Device on open True

# chdev -l hdisk558 -a reserve_lock=no -P

hdisk558 changed

2 Reboot the system for the changes to take effect.

34System requirementsSystem requirements

Page 35: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Fixed IssuesThis chapter includes the following topics:

■ Fixed issues

Fixed issuesThere are no fixed issues for Veritas Infoscale in this release.

8Chapter

Page 36: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Known IssuesThis chapter includes the following topics:

■ Issues related to installation and upgrade

■ Storage Foundation known issues

■ Replication known issues

■ Cluster Server known issues

■ Storage Foundation and High Availability known issues

■ Storage Foundation Cluster File System High Availability known issues

■ Storage Foundation for Oracle RAC known issues

■ Storage Foundation for Databases (SFDB) tools known issues

Issues related to installation and upgradeThis section describes the known issues during installation and upgrade. Theseknown issues apply to the following products:

■ Veritas InfoScale Foundation

■ Veritas InfoScale Storage

■ Veritas InfoScale Availability

■ Veritas InfoScale Enterprise

9Chapter

Page 37: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Notify sink resource and generic application resource moves toOFFLINE|UNKNOWN state after VCS upgrade [3806690]

If you use the high availability wizard to configure an application for monitoring, andlater upgrade to Availability 7.0, then the notify sink resource goes to theOFFLINE|UNKNOWN state.

If you used the wizard to configure an application for monitoring with the genericagent, then the (generic) application resource also goes to the OFFLINE|UNKNOWNstate.

This issue occurs because some file paths are modified in Veritas InfoScale 7.0.

Workaround:

Perform the following steps:

1. To resolve the file path issue for the notify sink resource, modify the PathNameattribute of the VCSNotifySinkRes resource by using the following commands:

■ Enable editing for the high availability configuration.# /opt/VRTSvcs/bin/haconf -makerw

■ Resolve the file path issue.# /opt/VRTSvcs/bin/hares -modify VCSNotifySinkRes PathName

/opt/VRTSvcs/portal/vcs_wizards/admin/notify_sink

■ Disable editing for the high availability configuration.# /opt/VRTSvcs/bin/haconf -dump -makero

2. To resolve the file path issue for the (generic) application resource, executethe following commands:

■ Determine the path to the program that the generic agent uses to monitorthe application resource.# /opt/VRTSvcs/bin/hares -value ResourceName MonitorProgram

Where ResourceName is the name of the monitored application resourceAn output along the following lines appears.

/opt/VRTSvcs/bin/Application/getServiceStatus PathToMonitorProgram

Where PathToMonitorProgram is the file path to the monitor program thatthe generic agent uses to monitor the application.

Note: The output also includes some arguments, which are part ofPathToMonitorProgram. Ensure that you specify both the path and thearguments, when you specify the value of PathToMonitorProgram in thefollowing commands.

37Known IssuesIssues related to installation and upgrade

Page 38: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

■ Enable editing for the high availability configuration.# /opt/VRTSvcs/bin/haconf -makerw

■ Resolve the file path issue.# /opt/VRTSvcs/bin/hares -modify ResourceName MonitorProgram

"/opt/VRTSvcs/bin/Application/getServiceStatus.wiz

PathToMonitorProgram"

■ Disable editing for the high availability configuration.# /opt/VRTSvcs/bin/haconf -dump -makero

In an upgraded cluster, security configuration may fail while importingVCS_SERVICES file. [3708929]

When the cluster is upgraded from 6.0.1 to 6.2.1, the utility atutil is upgraded to6.2.1, while the file of VCS_SERVICES remains as version 6.0.1. When a node isadded to a cluster, the security is configured for the newly added node.

The file of VCS_SERVICES required by the security configuration is taken from thenodes which are already present in the cluster. In this case, importing informationfrom VCS_SERVICES fails.

Workaround: If a new node is to be added, do the following:

1 Disable the security.

2 Disable the security.

3 Enable the security.

When the security is enabled, VCS_SERVICES for version 6.2.1 is used and securityconfigurations works.

But since you reconfigure the security on the cluster with new keys, all credentials(certificates) are newly created. And any trust already present needs to bere-established.

Switch fencing in enable or disable mode may not take effect if VCSis not reconfigured [3798127]

When you choose not to reconfigure Veritas Cluster Server (VCS), and set thefencing in enable or disable mode, it may not take effect. This is because the fencingmode switch relies on VCS reconfiguration.

Workaround: If you want to switch the fencing mode, when the installer shows "Doyou want to re-configure VCS?", enter y to reconfigure VCS .

38Known IssuesIssues related to installation and upgrade

Page 39: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

During an upgrade process, the AMF_START or AMF_STOP variablevalues may be inconsistent [3763790]

If the value of AMF_START or AMF_STOP variables in the driver configuration fileis ‘0’ before an upgrade, then after the upgrade is complete, the installer changesthe value to 1. Simultaneously, the installer also starts the Asynchronous MonitoringFramework (AMF) process.

Workaround: To resolve the issue, stop the AMF process and change theAMF_START or AMF_STOP value to 0.

Stopping the installer during an upgrade and then resuming theupgrade might freeze the service groups (2574731)

The service groups freeze due to upgrading using the product installer if you stoppedthe installer after the installer already stopped some of the processes and thenresumed the upgrade.

Workaround: You must unfreeze the service groups manually after the upgradecompletes.

To unfreeze the service groups manually

1 List all the frozen service groups

# hagrp -list Frozen=1

2 Unfreeze all the frozen service groups:

# haconf -makerw

# hagrp -unfreeze service_group -persistent

# haconf -dump -makero

If you have a shared (system) WPAR configured, when you install,upgrade, or uninstall any Symantec product, the filesets in theWPARare not synchronized correspondingly (3313690)

On AIX, if you have a shared (system) workload partition (WPAR) configured, whenyou perform an install, upgrade, or uninstall task on any Symantec product by theSymantec product installer, the filesets may not be installed, upgraded, or uninstalledcorrespondingly.

Workaround: After an install, upgrade, or uninstall task, execute the followingcommand to synchronize your WPAR with global systems:

39Known IssuesIssues related to installation and upgrade

Page 40: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

# /usr/sbin/syncwpar -A

NetBackup 6.5 or older version is installed on a VxFS file system(2056282)

If you have NetBackup 6.5 or older version installed on a VxFS file system andbefore upgrading to Storage Foundation (SF) 7.0, if you unmount all VxFS filesystems including the one that hosts the NetBackup binaries (/usr/openv), thenwhile upgrading to SF 7.0, the installer fails to check if NetBackup is installed onthe samemachine and uninstalls the shared infrastructure filesets VRTSpbx, VRTSat,and VRTSicsco. This causes NetBackup to stop working.

Workaround: Before you unmount the VxFS file system that hosts NetBackup,copy the /usr/openv/netbackup/bin/version file and/usr/openv/netbackup/version file to the /tmp directory. If you have clusteredNetBackup installed, you must also copy the/usr/openv/netbackup/bin/cluster/NBU_RSP file to the /tmp directory. After youunmount the NetBackup file system, manually copy these two version files from/tmp to their original directories. If you have clustered NetBackup installed, youmust also copy the /usr/openv/netbackup/bin/cluster/NBU_RSP file from /tmp

to its original directory.

If the version files' directories do not exist, create the directories:

# mkdir -p /usr/openv/netbackup/bin

# mkdir -p /usr/openv/netbackup/bin

Run the installer to finish the upgrade process. After upgrade process completes,remove the two version files and their directories.

If your system is already affected by this issue, then you must manually install theVRTSpbx, VRTSat, and VRTSicsco filesets after the upgrade process completes.

The VRTSvxvm fileset fails to install on a few cluster nodes becausethe template file is corrupted (2348780)

The installer debug log displays the failure of the errupdate command as following:errupdate -f /usr/lpp/VRTSvxvm/inst_root/VRTSvxvm.err. The errupdate

command gets invoked through /usr/lib/instl/install by the operating system.The command also fails for the VRTSvxfs, VRTSglm, and VRTSgms filesets.

The errupdate command generally creates a *.undo.err file to remove entriesfrom the Error Record Template Repository in case of failed installation or cleanup.However, in this case the *.undo.err file does not get generated as the errupdatecommand fails. Also, it is not possible to manually remove entries from the Error

40Known IssuesIssues related to installation and upgrade

Page 41: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Record Template Repository in order to undo the changes made by the failedinstallation, because the file is corrupted.

Workaround: Save a copy of the/var/adm/ras/errtmplt and /etc/trcfmt filesbefore you install the product. Replace /var/adm/ras/errtmplt and /etc/trcfmtfiles with the ones that you saved, when the installation fails because the templatefile is corrupted. Uninstall all the filesets you installed and reinstall.

After a locale change restart the vxconfig daemon (2417547,2116264)

You need to restart the vxconfig daemon you change the locale of nodes that useit. The vxconfig daemon starts at boot. If you have changed locale, you need torestart the daemon.

Workaround:Refer to the Storage Foundation Cluster File System High AvailabilityAdministrator's Guide for the section, "vxconfigd daemon recovery."

Storage Foundation known issuesThis section describes the known issues in this release of Storage Foundation (SF).These known issues apply to the following products:

■ Veritas InfoScale Foundation

■ Veritas InfoScale Storage

■ Veritas InfoScale Enterprise

Dynamic Multi-Pathing known issuesThis section describes the known issues in this release of Dynamic Multi-pathing(DMP).

Taking the IBM snapshot LUN offline might triggersub-path failover [3754175]When IBM Snapshot LUN is offline, disk scan by DMP restore daemon or DMP CLImay trigger path failover. The offline snapshot LUNs fail I/O, and correspondinglyDMP tries to failover to alternate path unaware of LUN being snapshot.

Workaround: You can ignore the failover messages.

41Known IssuesStorage Foundation known issues

Page 42: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

vxdmpadm exclude ctlr=emcp command doesn't excludePowerPath devices properly [3741636]When devices are under the PowerPath (PP) control, the following commandmightnot exclude all devices from the Veritas Volume Manager (VxVM) view.

# vxdmpadm exclude ctlr=emcp

Workaround: If devices are under PP control, you are not recommended to excludedevices using the ctlr option.

To exclude the devices, use any of the following commands:

# vxdmpadm exclude dmpnodename=<dmp-device-name>

# vxdmpadm exclude path=<path-name>

# vxdmpadm exclude product=<VID:PID>

If the AIX operating system is upgraded to 7.1TL2SP5 orhigher patch levels with the DMP native support enabled,the system may fail to boot and the DMP native supportmay not be successfully enabled after the update [3169854]If the AIX operating system is upgraded to 7.1TL2SP5 or higher patch levels withthe DMP native support enabled, the system may fail to boot. Further, the DMPnative support may not be successfully enabled for 7.1TL2SP5 or higher patchlevels. The following error can be observed:

$ vxdmpadm settune dmp_native_support=on

VxVM vxdmpadm ERROR V-5-1-16951 boot image size exceeding the system

limit, trying to recover

VxVM vxdmpadm ERROR V-5-1-16952 system recovery successful, but DMP

support for LVM bootability could not be enabled

VxVM vxdmpadm ERROR V-5-1-15690 Operation failed for one or more

volume groups

VxVM vxdmpadm ERROR V-5-1-15686 The following VG(s) could not be

migrated as could not enable DMP support for LVM bootability - rootvg

The problem occurs because AIX imposes a limit on the size of boot image. If theDMP native support is enabled, the size of boot image may exceed the allowablelimit and hence system fails to boot.

Workaround: It is not recommended to upgrade the operating system to 7.1TL2SP5or higher patch levels with the DMP native support enabled. There will be a patchpublished once the issue is resolved.

42Known IssuesStorage Foundation known issues

Page 43: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Veritas Volume Manager known issues

Mounting CFS under VVR may fail, after rolling upgradephase 1 on one node. [3764652]After rolling upgrade on phase 1, if you run mount cfsmount all on one of the nodesof the CFS cluster, the mount operation hangs or fails. It’s because there is someI/O pending on volumes.

Workaround:There is no workaround.

VRAS verifydata command fails without cleaning up thesnapshots created [3558199]The vradmin verifydata and the vradmin syncrvg commands leave behindresidues if terminated abnormally. These residues can be snapshot volumes ormount points.

Workaround:Remove the snapshot volumes and unmount the mount pointsmanually.

SmartIO VxVM cache invalidated after relayout operation(3492350)If a relayout operation is done on a volume that has SmartIO VxVM caching enabled,the contents of the cache for the volume may be invalidated.

Workaround:

This behavior is expected. There is no workaround.

Performance impact when a large number of disks arereconnected (2802698)If the storage connectivity is lost to part of the storage, the disk group configurationcopy is rebalanced to the disks that have connectivity. For example, if the storagefor an entire enclosure is removed from a disk group with muliple enclosures. Therebalancing process takes time, during which time the vxconfigd daemon is busyand does not respond to commands.

Veritas Volume Manager (VxVM) might report false serialsplit brain under certain scenarios (1834513)VxVM might detect and report a false serial split brain when all of the followingconditions are met:

43Known IssuesStorage Foundation known issues

Page 44: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

■ One or more arrays that provide the shared storage for the cluster are beingpowered off

■ At the same time when the arrays are being powered off, an operation thatrequires an internal transaction is initiated (such as VxVM configurationcommands)

In such a scenario, disk group import will fail with a split brain error and thevxsplitlines output will show 0 or 1 pools.

Workaround:

To recover from this situation

1 Retrieve the disk media identifier (dm_id) from the configuration copy:

# /etc/vx/diag.d/vxprivutil dumpconfig device-path

The dm_id is also the serial split brain id (ssbid)

2 Use the dm_id in the following command to recover from the situation:

# /etc/vx/diag.d/vxprivutil set device-path ssbid=dm_id

Co-existence check might fail for CDS disksIn Veritas Volume Manager (VxVM) 5.1 SP1 and later, VxVM introduces the abilityto support Cross-platform Data Sharing (CDS) on disks larger than 1 TB. VxVMuses the Solaris VTOC Table to initialize the cdsdisk layout on devices up to 1 TB.VxVM uses the GUID Partition Table (GPT) to initialize the cdsdisk layout on deviceslarger than 1 TB.

In layouts where Solaris VTOC Table is used for initialization (typically, when thedisk size has never exceeded 1 TB), the AIX co-existence label can be found atsector 7 and VxVM ID block (also known as HP co-existence label) can be foundat sector 16.

In layouts where GPT is used for initialization (typically, when the disk size iscurrently greater than or had earlier exceeded 1 TB), the AIX co-existence label isplaced at sector 55 and VxVM ID block (also known as HP co-existence label) isplaced at sector 64. Consequently, AIX utilities would not be able to recognize acdsdisk initialized using GPT to be a valid VxVM disk. Symantec is working withIBM and third party OEMs to enhance the co-existence check in these utilities.

Workaround: There is no workaround for this issue.

44Known IssuesStorage Foundation known issues

Page 45: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Recovery and rollback to original configuration may notsucceed if the system reboots while the online migrationsetup is in partial state (2611423)During online migration from LVM to VxVM volumes, if there is a system rebootwhen the migration setup is in partial state, that is, the start operation has notcompleted successfully, then the recover and abort operations might not be ableto recover and rollback the configuration.

Workaround: This needs manual intervention for cleanup, depending on the state,to restore the original configuration.

Disk group import of BCV LUNs using -o updateid and-ouseclonedev options is not supported if the disk grouphas mirrored volumes with DCO or has snapshots(2831658)VxVM uses guid stored in configuration to uniquely identify all objects. The datachange object (DCO) volume stores the guid of mirrors and snapshots. If the diskgroup is imported with -o updateid and -o useclonedev, it changes the guid ofobjects in VxVM configuration database and the guids stored in the DCO volumeare not updated. The operations involving DCO cannot find objects with the storedguid. This could lead to failure of certain operations involving DCO or could lead tounexpected behavior.

Workaround:

No workaround available.

After devices that are managed by EMC PowerPath loseaccess to storage, Veritas Volume Manager commandsare delayed (2757198)In an enviroment which includes devices that are managed by EMC PowerPath, astorage loss causes Veritas Volume Manager commands to be delayed. In theevent of storage loss, VxVM sends SCSI inquiry to each LUN path to check thehealth of path, which are delayed by the presence of EMC PowerPath.

Workaround:

There is no workaround available.

45Known IssuesStorage Foundation known issues

Page 46: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

vxresize does not work with layered volumes that havemultiple plexes at the top level (3301991)If a layered volume has multiple plexes at the top level, vxresize does not work.For example, if you add amirror to a concat-mirror volume for a third mirror snapshot.The vxresize operation fails with the following message:

VxVM vxassist ERROR V-5-1-2528 Volume volname built on layered volumes

have multiple plexes

VxVM vxresize ERROR V-5-1-4703 Problem running vxassist command for

volume volname, in diskgroup dgname

Workaround:

To resize the volume

1 After adding the mirror to the volume, take a snapshot using the plex.

2 Grow the volume and snapshot volume with vxresize

3 Reattach the snapshot volume to the source volume.

Importing a clone disk group fails after splitting pairs(3134882)When you import a clone disk group with the -o updateid option, the GUIDs of allthe objects are assigned new values. However, these values are not updated onthe maps in the data change object (DCO). When you initiate a volume recovery,it fails on the volumes having instant DCO (version >= 20) because it does not findthe objects corresponding to the GUIDs. In this situation, the DCO is consideredcorrupt and the volume remains inaccessible.

Workaround: Youmainly need the -o updateid option when you import the clonedisk group on the same host as the primary disk group. You can avoid using theoption by doing one of the following:

■ Import the clone disk group on a different host.

■ Deport the primary disk group before you import the clone disk group.

If the import of the clone disk group with -o updateid option or the recovery ofvolume thereafter fails with a message about the DCO being corrupted, this erroroccurs because the GUIDs are not being updated on the DCO implicitly. If theworkaround is not acceptable and you need to access the volume, you can removethe DCO. You can dissociate or remove the snapshots and then remove the DCOmanually to let the recovery proceed.

46Known IssuesStorage Foundation known issues

Page 47: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

The DMP EMC CLARiiON ASL does not recognize mirrorview not ready LUNs (3272940)On hosts that have EMC CLARiiON mirror view not ready LUNs, if you enable ordisable the switch port and then issue the vxdisk scandisks or vxdctl enable

command, I/O error messages are written continuously in the syslog.

The dynamic multi-pathing (DMP) request for providing information to identify mirrorview not ready LUNs through in-band SCSI command is pending with EMCengineering. Not ready LUNs are special kind of LUNs which reject all kinds of I/Orequests.

Because DMP does not recognize not ready LUNs, Veritas VolumeManager (VxVM)tries to bring them online. As part of the online process, VxVM issues I/Os to readthe disk private region. These I/Os fail and generate error messages in syslog.

Because of events that are generated as part of the online process, the vxattachdscript triggers the vxdisk scandisks command again. This cycle causes continuousI/O error messages. This problem can also cause other commands to run slowlybecause the VxVM configuration daemon (vxconfigd) is busy servicing vxdisk

scandisks.

Workaround:Stop the vxattachd script and set EMCCLARiiON values, as follows:

1 Disable the vxattachd process.

For more information on how to disable vxattachd and what features you loseif vxattachd is disabled, see the vxattachd man page

2 Set the following EMC CLARiiON values:

■ recoveryoption=fixedretry

■ retrycount=5

Enter:

vxdmpadm setattr enclosure enclosure_name recoveryoption=fixedretry \

retrycount=5

Running the vxdisk disk set clone=off command onimported clone disk group luns results in a mix of cloneand non-clone disks (3338075)If you do not specify a disk group name, the vxdisk set operation works on thedmname rather than the daname. If a dmname is the same as an existing daname, thevxdisk set operation reflects on the dm name.

47Known IssuesStorage Foundation known issues

Page 48: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Workaround: Use the following command syntax to set the attributes:

vxdisk -g diskgroup_name set dmname clone=off

For example:

vxdisk -g dg1 set eva4k6k0_12 clone=off

Restarting the vxconfigd daemon on the slave node aftera disk is removed from all nodes may cause the diskgroups to be disabled on the slave node (3591019)The issue occurs if the storage connectivity of a disk is removed from all the nodesof the cluster and the vxconfigd daemon is restarted on the slave node before thedisk is detached from the slave. All the disk groups are in the dgdisabled state onthe slave node, but show as enabled on the other nodes.

If the disk was detached before the vxconfigd daemon is restarted, the issue doesnot occur.

In a Flexible Shared Storage (FSS) environment, removing the storage connectivityon a node that contributes DAS storage to a shared disk group results in globalconnectivity loss because the storage is not connected elsewhere.

Workaround:

To prevent this issue:

Before restarting the vxconfigd daemon, if a disk in a shared disk group has lostconnectivity to all nodes in the cluster, make sure that the disk is in the detached

state. If a disk needs to be detached, use the following command:

# vxdisk check diskname

To resolve the issue after it has occurred:

If vxconfigd is restarted before the disks got detached, remove the node from thecluster and rejoin the node to the cluster.

Failback to primary paths does not occur if the node thatinitiated the failover leaves the cluster (1856723)When CVM is configured on non-A/A storage, if a node loses access to the storagethrough all the primary paths, then all the nodes in the cluster switches to thesecondary paths. If the node which raised the protocol leaves the cluster and if allthe rest of the nodes in the cluster are seeing the primary paths as healthy, thenfailback to primary paths never happens.

48Known IssuesStorage Foundation known issues

Page 49: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Issues if the storage connectivity to data disks is lost ona CVM slave node while vxconfigd was not running on thenode (2562889)If storage connectivity to data disks is lost on a CVM slave node while vxconfigdwas not running on the node, this may result in following issues when vxconfigd

comes up on this node:

■ The shared disk groups on the disconnected storage are marked as dgdisabledon the slave node only.

■ The shared disk groups are available to rest of the cluster nodes but notransactions, such as VxVM configuration changes, are possible on any shareddisk group.

■ Attempts to deport such shared disk groups will fail.

Workaround:

Do one of the following:

■ Remove the faulty slave node out of CVM cluster, restore storage connectivity,and rejoin the node to the cluster.

■ Restart vxconfigd on the CVM master node.

The vxcdsconvert utility is supported only on the masternode (2616422)The vxcdsconvert utility should be run only from the master node, not from theslave nodes of the cluster.

Re-enabling connectivity if the disks are in local failed(lfailed) state (2425977)In a Cluster Volume Manager (CVM) cluster, you can disable connectivity to thedisks at the controller or enclosure level with the vxdmpadm disable command. Inthis case, CVM may place the disks into the lfailed state. When you restoreconnectivity with the vxdmpadm enable command, CVMmay not automatically clearthe lfailed state. After enabling the controller or enclosure, you must run diskdiscovery to clear the locally failed state.

To run disk discovery

◆ Run the following command:

# vxdisk scandisks

49Known IssuesStorage Foundation known issues

Page 50: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Issues with the disk state on the CVM slave node whenvxconfigd is restarted on all nodes (2615680)When a CVM master node and a slave node have lost storage access, andvxconfigd is restarted on all nodes, the disk state on the CVM slave node showsas invalid.

Plex synchronization is not completed after resumingsynchronization on a newmaster when the original masterlost connectivity (2788077)When you run vxrecover -o force, it recovers only one subvolume and it cannotdetect that the rest of the volume needs recovery.

When you run the vxassist mirror command, you run the vxplex attcommandserially on each subvolume. If the failure happens before you start theattachoperation (need to mark the concerned plex as the attach operation is inprogress), vxrecover will not redo the attach operation because it cannot find anyrecord of the attach operation in progress.

Workaround:

Run the following command on each subvolume to manually recover the completevolume:

# usr/lib/vxvm/type/fsgen/vxplex -U fsgen -g diskgroup \

-o force useopt att volume plex

Amaster node is not capable of doing recovery if it cannotaccess the disks belonging to any of the plexes of avolume (2764153)A master node with missing disks is not capable of doing recovery, as it does nothave access to the disks belonging to any of the plexes of a volume.

Workaround:

If other nodes have access to the storage, they can do the recovery. Switch themaster role to some other node with better storage connectivity.

CVM fails to start if the first node joining the cluster hasno connectivity to the storage (2787713)If the first node joining the cluster has no connectivity to disks, the import of shareddisk groups fails. Other nodes that join the cluster later assume that the auto-importof disk groups is already done as part of the existing cluster processing.

50Known IssuesStorage Foundation known issues

Page 51: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Workaround:

Perform a master switch to the node that has connectivity to the disks. Then importthe disk groups manually.

CVMVolDg agent may fail to deport CVM disk group whenCVMDeportOnOffline is set to 1When CVMDeportOnOffline is set to 1, the CVM disk group is deported based onthe order in which the CVMVolDg resources are taken offline. If the CVMVolDgresources in the disk group contain a mixed setting of 1 and 0 for theCVMDeportOnOffline attribute, the disk group is deported only if the attribute valueis 1 for the last CVMVolDg resource taken offline. If the attribute value is 0 for thelast CVMVolDg resource taken offline, the disk group is not deported.

Workaround: If multiple CVMVolDg resources are configured for a shared diskgroup and the disk group is required to be deported during offline, set the value ofthe CVMDeportOnOffline attribute to 1 for all of the resources.

The vxsnap print command shows incorrect value forpercentage dirty [2360780]The vxsnap print command can display the percentage of regions that differbetween snapshots, shown as the %dirty. In SF 6.0, if this command is run whilethe volumes are online and being actively used, the shown %dirty may lag fromactual percentage dirty for instant snap data cache object (DCO) volumes. That is,the command output may show less %dirty than actual.

Mksysb restore fails if physical volumes have identicalPVIDs (3133542)When you have multiple paths to the rootvg devices, restoring a mksysb backupfile fails with the following error:

0516-1775 /usr/sbin/varyonvg: Physical volumes diskname1 and diskname2 have identical PVIDs.

This error is caused by an issue with IBM AIX.

Workaround:

Contact IBM support to obtain the fix. Refer to IBM APAR IV25286 for more details.

Veritas File System known issuesThis section describes the known issues in this release of Veritas File System(VxFS).

51Known IssuesStorage Foundation known issues

Page 52: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Delayed allocation may be turned off automatically whenone of the volumes in a multi-volume file system nears100%(2438368)Delayed allocation may be turned off automatically when one of the volumes in amulti-volume file system is in almost full usage, even if other volumes in the filesystem have free space.

Workaround: After sufficient space is freed from the volume, the delayed allocationautomatically resumes.

The file system deduplication operation fails with the errormessage "DEDUP_ERROR Error renaming X checkpointto Y checkpoint on filesystem Z error 16" (3348534)The file system deduplication operation fails with the error message"DEDUP_ERROR Error renaming X checkpoint to Y checkpoint on filesystem Zerror 16", due to the failure in unmounting the checkpoint.

Workaround: Retry the deduplication operation to resolve the problem.

Enabling delayed allocation on a small file system maydisable the file system (2389318)When you enable the delayed allocation on a small file system, such as around100 MB, the file system may be disabled. In this case, the following error messageis displays in the system console log:

mesg 001: V-2-1: vx_nospace - file_system file

system full (size block extent)

Workaround:Use the vxtunefs command for turning off the delayed allocation forthe file system.

The fsappadm subfilemove command moves all extentsof a file [3760225]This issue occurs when you run the fsppadm subfilemove command from a clusterfile system (CFS) secondary node. Then you specify a range of extents for relocationto a target tier.

If the extent size is greater than or equal to 32768, the fsppadm subfilemovecommand(1M) moves all extents of the specified table to the target tier. Theexpectation is to move a specified range of extents.

Workaround: On the CFS primary node, determine the primary node using one ofthe following commands:

52Known IssuesStorage Foundation known issues

Page 53: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

# fsclustadm showprimary mountpoint

# fsclustadm idtoname nodeid

dchunk_enable does not get set through vxtunefs in AIX(3551030)The vxtunefs command uses the oslevel -s command to get OS TL level, butthe OS level reports the lowest level of any installed AIX fileset on a system.Therefore, the oslevel command provides inaccurate OS level which may breakthe conditional logic inside VxFS.

Workaround:

To check which fileset is at a lower level and upgrade it to the recommendedlevel

1 This command shows which fileset is at a lower SP level:

#oslevel -s -l `oslevel -sq 2>/dev/null | sed -n '1p'`

2 This command shows which fileset is at a lower TL level :

#oslevel -r -l `oslevel -rq 2>/dev/null | sed -n '1p'`

3 Upgrade the lower TL level fileset.

For the recommended level:

Cannot use some commands from inside an automountedStorage Checkpoint (2490709)If your current work directory is inside an automounted Storage Checkpoint, forexample /mnt1/.checkpoint/clone1, some commands display the following error:

can't find current directory

This issue is verified with the following commands:

■ cp -r

■ du

However, this issue might occur with other commands.

Workaround: Run the command from a different directory.

53Known IssuesStorage Foundation known issues

Page 54: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

On the online cache device you should not perform themkfs operation, because any subsequent fscache operationpanics (3643800)When the mkfs operation is performed on a volume already in use for SmartIO,caching can lead to unexpected results when the subsequent sfcache operationsare performed.

Workaround:Workaround is not available.

Deduplication can fail with error 110 (3741016)In some cases, data deduplication fails with a message similar to the followingexample:

Saving Status Node Type Filesystem

---------------------------------------------------------------------

00% FAILED node01 MANUAL /data/fs1

2011/10/26 01:38:58 End full scan with error

In addition, the deduplication log contains an error similar to the following example:

2011/10/26 01:35:09 DEDUP_ERROR AddBlock failed. Error = 110

These errors indicate that the deduplication process is running low on space andneeds more free space to complete.

Workaround: Make more space available on the file system.

You are unable to unmount the NFS exported file systemon the server if you run the fsmigadm command on theclient (2355258)Unmounting the NFS-exported file system on the server fails with the "Device busy"error when you use the fsmigadm command on the NFS client.

Workaround: Unexport the file system prior to unmounting.

A restored volume snapshot may be inconsistent with thedata in the SmartIO VxFS cache (3760219)The data in a volume snapshot may have data that is inconsistent with the VxFSlevel SmartIO cache. When the volume snapshot is restored and mounted, thenbefore using that file system you should purge the corresponding cache data. Or,disable the caching for that file system.

Workaround:

54Known IssuesStorage Foundation known issues

Page 55: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Purge the file system data from the SmartIO cache after restoring the volumesnapshot.

# sfcache purge {mount_point|fsuuid}

When in-place and relocate compression rules are in thesame policy file, file relocation is unpredictable (3760242)You cannot have in-place compress/uncompress rules and relocatecompress/uncompress rules in the same policy file. If they are in the same file, filerelocation is unpredictable.

Workaround: Create a different policy file for each policy, and enforce the policyas per the required sequence.

The file system may hang when it has compressionenabled (3331276)In a VxFS file system that has compression enabled, a deadlock in page faulthandler can lead to the file system hang.

Workaround:

There is no workaround for this issue.

Unaligned large reads may lead to performance issues(3064877)On AIX, when there are unaligned large reads, there may be a performancedegradation.

Workaround:

There is no workaround for this issue.

Replication known issuesThis section describes the replication known issues in this release of VeritasInfoScale Storage and Veritas InfoScale Enterprise.

RVGPrimary agent operation to start replication between the originalPrimary and the bunker fails during failback (2036605)

The RVGPrimary agent initiated operation to start replication between the originalPrimary and the bunker fails during failback – when migrating back to the originalPrimary after disaster recovery – with the error message:

55Known IssuesReplication known issues

Page 56: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

VxVM VVR vxrlink ERROR V-5-1-5282 Error getting information from

remote host. Internal Error.

The issue applies to global clustering with a bunker configuration, where the bunkerreplication is configured using storage protocol. It occurs when the Primary comesback even before the bunker disk group is imported on the bunker host to initializethe bunker replay by the RVGPrimary agent in the Secondary cluster.

Workaround:

To resolve this issue

1 Before failback, make sure that bunker replay is either completed or aborted.

2 After failback, deport and import the bunker disk group on the original Primary.

3 Try the start replication operation from outside of VCS control.

A snapshot volume created on the Secondary, containing a VxFSfile system may not mount in read-write mode and performing aread-write mount of the VxFS file systems on the new Primary aftera global clustering site failover may fail [3761497]

Issue 1:

When the vradmin ibc command is used to take a snapshot of a replicated datavolume containing a VxFS file system on the Secondary, mounting the snapshotvolume in read-write mode may fail with the following error:

UX:vxfs mount: ERROR: V-3-21268: /dev/vx/dsk/dg/snapshot_volume

is corrupted. needs checking

This happens because the file system may not be quiesced before running thevradmin ibc command and therefore, the snapshot volume containing the filesystem may not be fully consistent.

Issue 2:

After a global clustering site failover, mounting a replicated data volume containinga VxFS file system on the new Primary site in read-write mode may fail with thefollowing error:

UX:vxfs mount: ERROR: V-3-21268: /dev/vx/dsk/dg/data_volume

is corrupted. needs checking

This usually happens because the file system was not quiesced on the originalPrimary site prior to the global clustering site failover and therefore, the file systemson the new Primary site may not be fully consistent.

56Known IssuesReplication known issues

Page 57: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Workaround: The following workarounds resolve these issues.

For issue 1, run the fsck command on the snapshot volume on the Secondary, torestore the consistency of the file system residing on the snapshot.

For example:

# fsck -V vxfs /dev/vx/dsk/dg/snapshot_volume

For issue 2, run the fsck command on the replicated data volumes on the newPrimary site, to restore the consistency of the file system residing on the datavolume.

For example:

# fsck -V vxfs /dev/vx/dsk/dg/data_volume

In an IPv6-only environment RVG, data volumes or SRL namescannot contain a colon (1672410, 1672417)

Issue: After upgrading VVR to an IPv6-only environment in release 6.0 or later,vradmin commands may not work when a colon is specified in the RVG, datavolume(s) and/or SRL name. It is also possible that after upgrading VVR to anIPv6-only environment, vradmin createpri may dump core when provided withRVG, volume and/or SRL names containing a colon in it.

Workaround: Make sure that colons are not specified in the volume, SRL, andRVG names in the VVR configuration

vxassist relayout removes the DCM (145413)If you perform a relayout that adds a column to a striped volume that has a DCM,the DCM is removed. There is no message indicating that this has happened. Toreplace the DCM, enter the following:

#vxassist -g diskgroup addlog vol logtype=dcm

vradmin functionality may not work after a master switch operation[2158679]

In certain situations, if you switch the master role, vradmin functionality may notwork. The following message displays:

VxVM VVR vxrlink ERROR V-5-1-15861 Command is not supported for

command shipping. Operation must be executed on master

57Known IssuesReplication known issues

Page 58: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Workaround:

To restore vradmin functionality after a master switch operation

1 Restart vradmind on all cluster nodes. Enter the following:

# /etc/init.d/vras-vradmind.sh stop

# /etc/init.d/vras-vradmind.sh start

2 Re-enter the command that failed.

Cannot relayout data volumes in an RVG from concat to striped-mirror(2129601)

This issue occurs when you try a relayout operation on a data volume which isassociated to an RVG, and the target layout is a striped-mirror.

Workaround:

To relayout a data volume in an RVG from concat to striped-mirror

1 Pause or stop the applications.

2 Wait for the RLINKs to be up to date. Enter the following:

# vxrlink -g diskgroup status rlink

3 Stop the affected RVG. Enter the following:

# vxrvg -g diskgroup stop rvg

4 Disassociate the volumes from the RVG. Enter the following:

# vxvol -g diskgroup dis vol

5 Relayout the volumes to striped-mirror. Enter the following:

# vxassist -g diskgroup relayout vol layout=stripe-mirror

6 Associate the data volumes to the RVG. Enter the following:

# vxvol -g diskgroup assoc rvg vol

7 Start the RVG. Enter the following:

# vxrvg -g diskgroup start rvg

8 Resume or start the applications.

58Known IssuesReplication known issues

Page 59: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

vradmin verifydata operation fails when replicating between versions5.1 and 6.0 or later (2360713)

When replicating in a cross-version VVR environment consisting of hosts runningStorage Foundation 5.1 and hosts running Storage Foundation 6.0 or later , thevradmin verifydata command fails with the following error:

VxVM VVR vxrsync ERROR V-5-52-2222 [from host]: VxVM in.vxrsyncd

ERROR V-5-36-2125 Server volume access error during [assign volids]

volume path: [/dev/vx/dsk/dg/snapshot_volume] reason: [this could be

because a target volume is disabled or an rlink associated with a

target volume is not detached during sync operation].

Workaround: There are two workarounds for this issue.

■ Upgrade the hosts running Storage Foundation 5.1 to Storage Foundation 6.0or later and re-run the vradmin verifydata command.

■ Follow the offline verification procedure in the "Verifying the data on theSecondary" section of the Veritas InfoScale Replication Administrator's Guide.This process requires ensuring that the secondary is up-to-date, pausingreplication, and running the vradmin syncrvg command with the -verify

option.

vradmin verifydata may report differences in a cross-endianenvironment (2834424)

When replicating between two nodes in a cross-platform environment, andperforming an autosync or replication, the vradmin verifydata command may reportdifferences. This is due to different endianness between the platforms. However,the file system on the secondary node will be consistent and up to date.

vradmin verifydata operation fails if the RVG contains a volume set(2808902)

In a VVR environment, the vradmin verifydata command fails with the followingerror if the replicated volume group (RVG) contains any volume set:

Message from Primary:

VxVM VVR vxrsync ERROR V-5-52-2009 Could not open device

/dev/vx/dsk/vvrdg/<volname> due to: stat of raw character volume path

failed

59Known IssuesReplication known issues

Page 60: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Bunker replay does not occur with volume sets (3329970)There are issues with bunker replication using Volume Replicator (VVR) with volumesets. Do not upgrade to Storage Foundation HA 7.0 if you have configured or planto configure bunker replication using VVR with volume sets.

Workaround:

Contact Symantec Technical Support for a patch that enables you to use thisconfiguration.

During moderate to heavy I/O, the vradmin verifydata commandmayfalsely report differences in data (3270067)

While an application is online at the Volume Replicator primary site, the vradmin

verifydata commandmay fail. The command output shows the differences betweenthe source data volume and the target data volume.

Workaround:

The reason for this error is that the cache object that is used for the verificationmight be under allocated. You might need to allocate more space for the sharedcache object. For guidelines on shared cache object allocation, see the section"Creating a shared cache object" in the Storage Foundation Administrator's Guide.

The vradmin repstatus command does not show that the SmartSyncfeature is running [3343141]

In a Volume Replicator (VVR) environment, after you start the initial synchronizationwith the vradmin -a startrep command with file system mounted on the primarydata volumes, the vradmin repstatus command does not show that the SmartSyncfeature is running. This is an only issue with the output of the vradmin repstatus

command.

Workaround:

To confirm that SmartSync is running, enter:

vxrlink status rlink

While vradmin commands are running, vradmind may temporarilylose heartbeats (3347656, 3724338)

This issue may occasionally occur when you use vradmin commands to administerVolume Replicator (VVR). While the vradmin commands run, vradmind may

60Known IssuesReplication known issues

Page 61: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

temporarily lose heartbeats, and the commands terminate with the following errormessage:

VxVM VVR vradmin ERROR V-5-52-803 Lost connection to host host;

terminating command execution.

Workaround:

To resolve this issue:

1 Depending on the application I/O workload and the network environment,uncomment and increase the value of the IPM_HEARTBEAT_TIMEOUT variablein the/etc/vx/vras/vras_env on all the hosts of the replicated data set (RDS)to a higher value. The following example increases the timeout value to 120seconds:

export IPM_HEARTBEAT_TIMEOUT

IPM_HEARTBEAT_TIMEOUT=120

2 Restart vradmind on all the hosts of the RDS to put thenewIPM_HEARTBEAT_TIMEOUT value into affect. Enter the following on all thehosts of the RDS:

# /etc/init.d/vras-vradmind.sh stop

# /etc/init.d/vras-vradmind.sh start

Write I/Os on the primary logowner may take a long time to complete(2622536)

Under a heavy I/O load, write I/Os on the Volume Replicator (VVR) primary logownertake a long time to complete.

Workaround:

There is no workaround for this issue.

DCM logs on a disassociated layered data volume results inconfiguration changes or CVM node reconfiguration issues (3582509)

If you have configured layered data volumes under an RVG that has DCM protectionenabled and at a later point disassociate the data volume from the RVG, you mustmanually remove the DCM logs from the volume. Leaving DCM logs on a layereddata volume after it has been disassociated from the RVG, may result configurationchanges, or the CVM node reconfiguration to not work properly.

Workaround:

61Known IssuesReplication known issues

Page 62: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

If the disk group has a layered volume, remove DCM logs after disassociating thevolumes from the RVG.

After performing a CVM master switch on the secondary node, bothrlinks detach (3642855)

If the VVR logowner (master) node on the secondary site goes down during initialsynchronization, then during the RVG recovery (initiated on any secondary sidenode as a result of node crash), the replication links detach with the following error:

WARNING: VxVM VVR vxio V-5-0-187 Incorrect magic number or unexpected

upid (1) rvg rvg1

WARNING: VxVM VVR vxio V-5-0-287 rvg rvg1, SRL srl1: Inconsistent log

- detaching all rlinks.

Workaround:

Restart replication using the autosync operation.

The RVGPrimary agent may fail to bring the application service grouponline on the new Primary site because of a previous primary-electoperation not being run or not completing successfully (3761555,2043831)

In a primary-elect configuration, the RVGPrimary agent may fail to bring theapplication service groups online on the new Primary site, due to the existence ofpreviously-created instant snapshots. This may happen if you do not run theElectPrimary command to elect the new Primary or if the previous ElectPrimarycommand did not complete successfully.

Workaround: Destroy the instant snapshots manually using the vxrvg -g dg -P

snap_prefix snapdestroy rvg command. Clear the application service groupand bring it back online manually.

A snapshot volume created on the Secondary, containing a VxFSfile system may not mount in read-write mode and performing aread-write mount of the VxFS file systems on the new Primary aftera global clustering site failover may fail (1558257)

Issue 1:

62Known IssuesReplication known issues

Page 63: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

When the vradmin ibc command is used to take a snapshot of a replicated datavolume containing a VxFS file system on the Secondary, mounting the snapshotvolume in read-write mode may fail with the following error:

UX:vxfs mount: ERROR: V-3-21268: /dev/vx/dsk/dg/snapshot_volume

is corrupted. needs checking

This happens because the file system may not be quiesced before running thevradmin ibc command and therefore, the snapshot volume containing the filesystem may not be fully consistent.

Issue 2:

After a global clustering site failover, mounting a replicated data volume containinga VxFS file system on the new Primary site in read-write mode may fail with thefollowing error:

UX:vxfs mount: ERROR: V-3-21268: /dev/vx/dsk/dg/data_volume

is corrupted. needs checking

This usually happens because the file system was not quiesced on the originalPrimary site prior to the global clustering site failover and therefore, the file systemson the new Primary site may not be fully consistent.

Workaround: The following workarounds resolve these issues.

For issue 1, run the fsck command on the snapshot volume on the Secondary, torestore the consistency of the file system residing on the snapshot.

For example:

# fsck -V vxfs /dev/vx/dsk/dg/snapshot_volume

For issue 2, run the fsck command on the replicated data volumes on the newPrimary site, to restore the consistency of the file system residing on the datavolume.

For example:

# fsck -V vxfs /dev/vx/dsk/dg/data_volume

Cluster Server known issuesThis section describes the known issues in this release of Cluster Server (VCS).These known issues apply to the following products:

■ Veritas InfoScale Availability

■ Veritas InfoScale Enterprise

63Known IssuesCluster Server known issues

Page 64: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Operational issues for VCSThis section describes the Operational known issues for VCS.

Connecting to the database outside VCS control usingsqlplus takes too long to respondConnecting to start the database outside VCS control, using sqlplus takes morethan 10 minutes to respond after pulling the public network cable. [704069]

SomeVCS components do not work on the systemswherea firewall is configured to block TCP trafficThe following issues may occur if you install and configure VCS on systems wherea firewall is installed:

■ If you set up Disaster Recovery using the Global Cluster Option (GCO), thestatus of the remote cluster (cluster at the secondary site) shows as "initing".

■ If you configure fencing to use CP server, fencing client fails to register with theCP server.

■ Setting up trust relationships between servers fails.

Workaround:

■ Ensure that the required ports and services are not blocked by the firewall. Referto the Cluster Server Configuration and Upgrade Guide for the list of ports andservices used by VCS.

■ Configure the firewall policy such that the TCP ports required by VCS are notblocked. Refer to your respective firewall or OS vendor documents for therequired configuration.

CP server does not allow adding and removing HTTPSvirtual IP or ports when it is running [3322154]CP server does not support adding and removing HTTPS virtual IPs or ports whilethe CP server is running. However, You can add or remove the IPM virtual IPs orports.

Workaround: No workaround. If you want to add a new virtual IP for HTTPS, youmust follow the entire manual procedure for generating HTTPS certificate for theCP server (server.crt), as documented in the Cluster Server Configuration andUpgrade Guide.

64Known IssuesCluster Server known issues

Page 65: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

CP server does not support IPv6 communication withHTTPS protocol [3209475]CP server does not support IPv6 communication when using the HTTPS protocol.This implies that in VCS, CP servers listening on HTTPS can only use IPv4. As aresult, VCS fencing clients can also use only IPv4.

Workaround: No workaround.

SomeVCS components do not work on the systemswherea firewall is configured to block TCP traffic [3545338]The following issues may occur if you install and configure VCS on systems wherea firewall is installed:

■ If you set up Disaster Recovery using the Global Cluster Option (GCO), thestatus of the remote cluster (cluster at the secondary site) shows as "initing".

■ If you configure fencing to use CP server, fencing client fails to register with theCP server.

■ Setting up trust relationships between servers fails.

Workaround:

■ Ensure that the required ports and services are not blocked by the firewall. Referto the Cluster Server Configuration and Upgrade Guide for the list of ports andservices used by VCS.

■ Configure the firewall policy such that the TCP ports required by VCS are notblocked. Refer to your respective firewall or OS vendor documents for therequired configuration.

Issues related to the VCS engineThis section describes the knonw issues about the VCS engine.

Extremely high CPU utilization may cause HAD to fail toheartbeat to GAB [1744854]When CPU utilization is very close to 100%, HAD may fail to heartbeat to GAB.

The hacf -cmdtocf command generates a broken main.cffile [1919951]The hacf -cmdtocf command used with the -dest option removes the includestatements from the types files.

65Known IssuesCluster Server known issues

Page 66: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Workaround: Add include statements in the main.cf files that are generated usingthe hacf -cmdtocf command.

VCS fails to validate processor ID while performing CPUBinding [2441022]If you specify an invalid processor number when you try to bind HAD to a processoron a remote system, HAD does not bind to any CPU. However, the commanddisplays no error to indicate that the specified CPU does not exist. The error islogged on the node where the binding has failed and the values are reverted todefault.

Workaround: Symantec recommends that you modify CPUBinding from the localsystem.

Trigger does not get executed when there is more thanone leading or trailing slash in the triggerpath [2368061]The path specified in TriggerPath attribute must not contain more than one leadingor trailing '/' character.

Workaround: Remove the extra leading or trailing '/' characters from the path.

Service group is not auto started on the node havingincorrect value of EngineRestarted [2653688]When HAD is restarted by hashadow process, the value of EngineRestarted attributeis temporarily set to 1 till all service groups are probed. Once all service groups areprobed, the value is reset. If HAD on another node is started at roughly the sametime, then it is possible that it does not reset the value of EngineRestarted attribute.Therefore, service group is not auto started on the new node due to mismatch inthe value of EngineRestarted attribute.

Workaround: Restart VCS on the node where EngineRestarted is set to 1.

Group is not brought online if top level resource isdisabled [2486476]If the top level resource which does not have any parent dependancy is disabledthen the other resources do not come online and the followingmessage is displayed:

VCS NOTICE V-16-1-50036 There are no enabled

resources in the group cvm to online

Workaround: Online the child resources of the topmost resource which is disabled.

66Known IssuesCluster Server known issues

Page 67: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

NFS resource goes offline unexpectedly and reports errorswhen restarted [2490331]VCS does not perform resource operations, such that if an agent process is restartedmultiple times by HAD, only one of the agent process is valid and the remainingprocesses get aborted, without exiting or being stopped externally. Even thoughthe agent process is running, HAD does not recognize it and hence does not performany resource operations.

Workaround: Terminate the agent process.

Parent group does not come online on a node where childgroup is online [2489053]This happens if the AutostartList of parent group does not contain the node entrywhere the child group is online.

Workaround: Bring the parent group online by specifying the name of the systemthen use the hargp -online [parent group] -any command to bring the parentgroup online.

Cannot modify temp attribute when VCS is in LEAVINGstate [2407850]An ha command to modify a temp attribute is rejected if the local node is in aLEAVING state.

Workaround: Execute the command from another node or make the configurationread-write enabled.

Service group may fail to come online after a flush and aforce flush operation [2616779]A service group may fail to come online after flush and force flush operations areexecuted on a service group where offline operation was not successful.

Workaround: If the offline operation is not successful then use the force flushcommands instead of the normal flush operation. If a normal flush operation isalready executed then to start the service group use -any option.

Elevated TargetCount prevents the online of a servicegroup with hagrp -online -sys command [2871892]When you initiate an offline of a service group and before the offline is complete,if you initiate a forced flush, the offline of the service group which was initiated

67Known IssuesCluster Server known issues

Page 68: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

earlier is treated as a fault. As start bits of the resources are already cleared, servicegroup goes to OFFLINE|FAULTED state but TargetCount remains elevated.

Workaround: No workaround.

System sometimes displays error message withvcsencrypt or vcsdecrypt [2850899]If random number generator is not configured on your system and you run vcsencryptor vcsdecrypt, the system sometimes displays the following error message:

VCS ERROR V-16-1-10351 Could not set FIPS mode

Workaround: Ensure that the random number generator is defined on your systemfor encryption to work correctly. Typically, the files required for random numbergenerator are /dev/random and /dev/urandom.

Auto failover does not happen in case of two successiveprimary and secondary cluster failures [2858187]

In case of three clusters (clus1, clus2, clus3) in a GCOwith steward not configured,if clus1 loses connection with clus2, it sends the inquiry to clus3 to check the stateof clus2 one of the following condition persists:

1. If it is able to confirm that clus2 is down, it will mark clus2 as FAULTED.

2. If it is not able to send the inquiry to clus3, it will assume that a networkdisconnect might have happened and mark clus2 as UNKNOWN

In second case, automatic failover does not take place even if theClusterFailoverPolicy is set to Auto. You need to manually failover the global servicegroups.

Workaround: Configure steward at a geographically distinct location from the clustersto which the above stated condition is applicable.

GCO clusters remain in INIT state [2848006]GCO clusters remain in INIT state after configuring GCO due to :

■ Trust between two clusters is not properly set if clusters are secure.

■ Firewall is not correctly configured to allow WAC port (14155).

Workaround: Make sure that above two conditions are rectified. Refer to ClusterServer Administrator's Guide for information on setting up Trust relationshipsbetween two clusters.

68Known IssuesCluster Server known issues

Page 69: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

The ha commands may fail for non-root user if cluster issecure [2847998]The ha commands fail to work for one of the following reasons:

■ If you first use a non-root user without a home directory and then create a homedirectory for the same user.

■ If you configure security on a cluster and then un-configure and reconfigure it.

Workaround

1 Delete /var/VRTSat/profile/<user_name>,

2 Delete /home/user_name/.VRTSat.

3 Delete /var/VRTSat_lhc/<cred_file> file which same non-root user owns.

4 Run ha command with same non-root user (this will pass).

Every ha command takes longer time to execute on secureFIPS mode clusters [2847997]In secure FIPS mode cluster, ha commands take 2-3 seconds more time than insecure cluster without FIPSmode for non-root users. This additional time is requiredto perform the FIPS self-tests before the encryption module can be used in FIPSmode.

Workaround: No workaround.

Running -delete -keys for any scalar attribute causescore dump [3065357]Running -delete -keys for any scalar attribute is not a valid operation and mustnot be used. However, any accidental or deliberate use of this commandmay causeengine to core dump.

Workaround: No workaround.

Veritas Infoscale enters into admin_wait state whenClusterStatistics is enabled with load and capacity defined[3199210]Veritas Infoscale enters into admin_wait state when started locally if:

1. Statistics attribute value is set to Enabled, which is its default value.

2. Group Load and System Capacity values are defined in units in main.cf.

Workaround:

69Known IssuesCluster Server known issues

Page 70: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

1. Stop Veritas Infoscale on all nodes in the cluster.

2. Perform any one of the following steps:

■ Edit the main.cf on one of the nodes in the cluster and set the Statisticsattribute to Disabled or MeterHostOnly.

■ Remove the Group Load and System Capacity values from the main.cf.

3. Run hacf -verify on the node to verify that the configuration is valid.

4. Start Veritas Infoscale on the node and then on the rest of the nodes in thecluster.

Agent reports incorrect state if VCS is not set to startautomatically and utmp file is empty before VCS is started[3326504]If you have not configured VCS to start automatically after a reboot and have tmptiedthe utmp file before starting VCSmanually with the hastart command, some agentsmight report an incorrect state.

The utmp file (file namemay differ on different operating systems) is used to maintaina record of the restarts done for a particular machine. The checkboot utility usedby hastart command uses the functions provided by the OS which in turn use theutmp file to find if a system has been restarted so that the temporary files for variousagents can be deleted before agent startup. If OS functions do not return correctvalue, High Availability Daemon (HAD) starts without deleting the stale agent files.This might result in some agents reporting incorrect state.

Workaround: If a user wishes to delete the utmp file this should be done only whenVCS is already running or the customer should delete the temporary filesin/var/VRTSvcs/lock/volatile/ manually before starting VCS.

VCS crashes if feature tracking file is corrupt [3603291]VCS keeps a track of some specific features used in the VCS cluster. For example,if a Global service group is brought online then the feature is logged in a specificfeature tracking file. If the file however is corrupt, then VCS may dump core whenattempting to write data to the file.

Workaround: Delete the corrupt feature tracking file (/var/vx/vftrk/vcs) andrestart VCS.

70Known IssuesCluster Server known issues

Page 71: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

RemoteGroup agent and non-root users may fail toauthenticate after a secure upgrade [3649457]On upgrading a secure cluster to 6.2 or later release, the following issues may occurwith unable to open a secure connection error:

■ The RemoteGroup agent may fail to authenticate with remote cluster.

■ WPAR users and non-root users may fail to authenticate.

Workaround

1 Set LC_ALL=C on all nodes before upgrade or perform the following steps afterthe upgrade on all nodes of the cluster:

■ Stop HAD.

■ Set LC_ALL=C.

■ Start HAD using hastart.

2 Reset LC_ALL attribute to the previous value once the WPAR and non-rootusers are validated.

Issues related to the bundled agentsThis section describes the known issues of the bundled agents.

VCS resources may time out if NFS server is down[2129617]The VCS resources may time out if the server NFS mounted file system and theNFS server is down or inaccessible. This behavior is exclusive to AIX platform.

Workaround: You must unmount the NFSmounted file system to restore the clusterto sane condition.

MultiNICB resource may show unexpected behavior withIPv6 protocol [2535952]When using IPv6 protocol, set the LinkTestRatio attribute to 0. If you set the attributeto another value, the MultiNICB resource may show unexpected behavior.

Workaround: Set the LinkTestRatio attribute to 0.

Bringing the LPAR resource offline may fail [2418615]Bringing the LPAR resource offline may fail with the following message in theengine_A.log file.

71Known IssuesCluster Server known issues

Page 72: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

<Date Time> VCS WARNING V-16-10011-22003 <system_name>

LPAR:<system_name>:offline:Command failed to run on MC

<hmc_name> with error HSCL0DB4 An Operating System

Shutdown can not be performed because the operating system image

running does not support remote execution of this task from the HMC.

This may be due to problem in communication with

MC <hmc_name>

This is due to RMC failure between HMC and management LPAR. Since the LPARcould not be shutdown gracefully in offline, the LPAR is shutdown forcefully in theclean call, hence it shows as Faulted.

Workaround: In order to recycle the RSCT deamon for LPAR and HMC, refer theStorage Foundation and High Availability Solutions Virtualization Guide.

LPAR agent may not show the correct state of LPARs[2425990]When the Virtual I/O server (VIOS) gets restarted, LPAR agent may not get thecorrect state of the resource. In this case, the LPAR agent may not show the correctstate of the LPAR.

Workaround: Restart the management LPAR and all the managed LPARs thatdepend on the VIOS.

RemoteGroup agent does not failover in case of networkcable pull [2588807]ARemoteGroup resource with ControlMode set to OnOff may not fail over to anothernode in the cluster in case of network cable pull. The state of the RemoteGroupresource becomes UNKNOWN if it is unable to connect to a remote cluster.

Workaround:

■ Connect to the remote cluster and try taking offline the RemoteGroup resource.

■ If connection to the remote cluster is not possible and you want to bring downthe local service group, change the ControlMode option of the RemoteGroupresource to MonitorOnly. Then try taking offline the RemoteGroup resource.Once the resource is offline, change the ControlMode option of the resource toOnOff.

CoordPoint agent remains in faulted state [2852872]The CoordPoint agent remains in faulted state because it detects rfsm to be inreplaying state.

72Known IssuesCluster Server known issues

Page 73: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Workaround: After HAD has stopped, reconfigure fencing.

Prevention of Concurrency Violation (PCV) is notsupported for applications running in a container [2536037]For an application running in a container, VCS uses a similar functionality as if thatresource is not registered to IMF. Hence, there is no IMF control to take a resourceoffline. When the same resource goes online on multiple nodes, agent detects andreports to engine. Engine uses the offline monitor to take the resource offline. Hence,even though there is a time lag before the detection of the same resource comingonline on multiple nodes at the same time, VCS takes the resource offline.

PCV does not function for an application running inside a WPAR on AIX.

Workaround: No workaround.

VCS does not monitor applications inside an alreadyexisting WPAR [2494532]If a WPAR is already present on the system at the time of VCS installation, and thisWPAR or an application running inside this WPAR needs to be monitored usingVCS, then VCS does not monitor the application running in that WPAR. This isbecause the VCS packages/files are not visible inside that WPAR.

Workaround: Run syncwpar command for that WPAR. This makes the VCSpackages/files visible inside the WPAR and VCS can then monitor the applicationsrunning inside the WPAR.

Error messages for wrong HMC user and HMC name donot communicate the correct problemThe wrong HMC user and wrong HMC name errorsd are not reflective of the correctproblem. If you see the following errors in engine_A.log for LPAR resource, it meanswrong HMC user:

Permission denied, please try again

Permission denied, please try again

If you see the following errors in engine_A.log for LPAR resource, it means wrongHMC name:

ssh: abc: Hostname and service name

not provided or found.

You must see the applicationha_utils.log file to confirm the same.

73Known IssuesCluster Server known issues

Page 74: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

LPAR agent may dump core when all configured VIOS aredown [2850898]When using Virtual Input Output Servers (VIOS), the LPARs need a restart afterVIOS restart/reboot/crash. If management LPAR is not restarted after VIOS isrebooted, then LPAR agent may dump core.

Workaround: Restart the management LPARwhich was depended on the rebootedVIOS.

NFS client reports I/O error because of network split brain[3257399]When network split brain occurs, the failing node may take some time to panic. Asa result, the service group on the failover node may fail to come online as some ofthe resources (such as IP resource) are still online on the failing node. The diskgroup on the failing node may also get disabled but IP resource on the same nodecontinues to be online.

Workaround: Configure the preonline trigger for the service groups containingDiskGroup resource with reservation on each system in the service group:

1 Copy the preonline_ipc trigger from/opt/VRTSvcs/bin/sample_triggers/VRTSvcs to/opt/VRTSvcs/bin/triggers/preonline/ as T0preonline_ipc:

# cp /opt/VRTSvcs/bin/sample_triggers/VRTSvcs/preonline_ipc

/opt/VRTSvcs/bin/triggers/preonline/T0preonline_ipc

2 Enable the preonline trigger for the service group.

# hagrp -modify <group_name> TriggersEnabled

PREONLINE -sys <node_name>

WPAR-aware agents cannot run in a non-shared WPAR[3313698]Non-shared WPAR has writable /usr file system and /opt file system local toWPAR. The common product installer installs VCS packages in /opt/VRTSvcsandlibraries in /usr/lib in a global environment. As VCS packages cannot besynchronized with a local copy of /usr and /opt on a non-shared WPAR, they arenot available to the non-sharedWPAR. Therefore in absence of the VCS packages,agents which are configured to monitor applications inside non-shared WPARcannot run.

74Known IssuesCluster Server known issues

Page 75: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Workaround: No workaround.

Mount resource does not support spaces in theMountPointand BlockDevice attribute values [3335304]Mount resource does not handle intermediate spaces in the configured MountPointor BlockDevice attribute values.

Workaround: No workaround.

Mount agent fails to onlineMount resource due toOS issue[3508584]Mount resource is configured with jfs2 file system.While bringing theMount resourceonline, the resource may fault with the following log message due to the IBM issueIZ773575.

mount: <Device_Path> on <Mount_Path>: Device busy

The current volume is: <Device_Path>

Open volume exclusive read or write returned, rc = 16

fsck: 0507-289 Device unavailable or locked by another process.

Cannot continue.

Workaround: The online operation for Mount resource internally calls the fsck

command if mount command fails. IBM recommends re-running the fsck commandto resolve the issue. Hence, increase the OnlineRetryLimit value for Mount resourceto a higher value than its default value.

SFCache Agent fails to enable caching if cache area isoffline [3644424]SFCache agent cannot enable caching if cache area associate with this particularobject is in offline state. User need to manually online the cache area to make surethat caching can be enabled/disabled.

Workaround: Online the cache area using sfcache command

# sfcache online <cache_area_name>

RemoteGroup agent may stop working on upgrading theremote cluster in secure mode [3648886]RemoteGroup agent may report the resource state as UNKNOWN if the remotecluster is upgraded to VCS 6.2 or later in secure mode.

Workaround: Restart the RemoteGroup agent.

75Known IssuesCluster Server known issues

Page 76: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Issues related to the VCS database agentsThis section describes the known issues about VCS database agents.

The ASMInstAgent does not support having pfile/spfile forthe ASM Instance on the ASM diskgroupsThe ASMInstAgent does not support having pfile/spfile for the ASM Instance onthe ASM diskgroups.

Workaround:

Have a copy of the pfile/spfile in the default $GRID_HOME/dbs directory to makesure that this would be picked up during the ASM Instance startup.

VCS agent for ASM: Health check monitoring is notsupported for ASMInst agentThe ASMInst agent does not support health check monitoring.

Workaround: Set the MonitorOption attribute to 0.

NOFAILOVER action specified for certain Oracle errorsThe High Availability agent for Oracle provides enhanced handling of Oracle errorsencountered during detailed monitoring. The agent uses the reference fileoraerror.dat, which consists of a list of Oracle errors and the actions to be taken.

See the Cluster Server Configuration and Upgrade Guide for a description of theactions.

Currently, the reference file specifies the NOFAILOVER action when the followingOracle errors are encountered:

ORA-00061, ORA-02726, ORA-6108, ORA-06114

TheNOFAILOVER actionmeans that the agent sets the resource’s state to OFFLINEand freezes the service group. You may stop the agent, edit the oraerror.dat file,and change the NOFAILOVER action to another action that is appropriate for yourenvironment. The changes go into effect when you restart the agent.

IMF registration fails if sybase server name is given at theend of the configuration file [2365173]AMF driver supports a maximum of 80 characters of arguments. In order for AMFto detect the start of the Sybase process, the Sybase server name must occur inthe first 80 characters of the arguments.

76Known IssuesCluster Server known issues

Page 77: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Workaround: Must have the server name, -sSYBASE_SERVER, as the first line inthe configuration file: ASE-15_0/install/RUN_SYBASE_SERVER.

Oracle agent fails to offline pluggable database (PDB)resource with PDB in backup mode [3592142]If the PDB is in backup mode and if you attempt to offline the corresponding PDBresource, this will cause PDB resource to go into “Unable to Offline” state.

Workaround: Manually remove the PDB from the backup mode before attemptingto take the PDB resource offline.

Clean succeeds for PDB even as PDB staus is UNABLEto OFFLINE [3609351]Oracle does not allow any operation on a PDB when the PDB is in backup mode.This is an expected behavior of Oracle. Therefore, a shutdown fails when it isinitiated on a PDB in backup mode and returns an UNABLE TO OFFLINE statusfor the PDB. If PDB is removed from the backup mode using the SQL script, theagent framework is unable to change the UNABLE TO OFFLINE status of the PDBas clean is called. Since Oracle does not differntiate between clean and offline forPDB, clean succeeds for the PDB in spite of being in UNABLE TO OFFLINE state.

Workaround: No workaround.

Second level monitoring fails if user and table names areidentical [3594962]If the table inside CDB has same name as the user name, second level monitoringfails and Oracle agent fails to update the table. For example, if user name isc##pdbuser1 and table is created as c##pdbuser1.vcs, then Oracle agent is unableto update it.

Workaround: Avoid having identical user and CDB table names.

Monitor entry point times out for Oracle PDB resourceswhen CDB is moved to suspended state in Oracle 12.1.0.2[3643582]In Oracle-12.1.0.2.0, when CDB is in SUSPENDEDmode, then the SQL commandfor PDB view (v$pdbs) hangs. Due to this, the monitor entry point in PDB gets timedout and there is no issue found in oracle-12.1.0.1.0 .

Workaround: No workaround.

77Known IssuesCluster Server known issues

Page 78: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Oracle agent fails to online and monitor Oracle instanceif threaded_execution parameter is set to true [3644425]In Oracle 12c, the threaded execution feature is enabled. The multithreaded OracleDatabase model enables Oracle processes to execute as operating system threadsin separate address spaces. If Oracle Database 12c is installed, the database runsin the process mode. If you set a parameter to run the database in threaded mode,some background processes on UNIX and Linux run with each process containingone thread, whereas the remaining Oracle processes run as threads within theprocesses.

When you enable this parameter, Oracle agent is unable to check smon (mandatoryprocess check) and lgwr (optional process check) processes which where tradtionallyused for monitoring and which now run as threads.

Workaround: Disable the threaded execution feature as it is no supported on Oracle12C.

Issues related to the agent frameworkThis section describes the known issues about the agent framework.

Agent framework cannot handle leading and trailing spacesfor the dependent attribute (2027896)Agent framework does not allow spaces in the target resource attribute name ofthe dependent resource.

Workaround: Do not provide leading and trailing spaces in the target resourceattribute name of the dependent resource.

The agent framework does not detect if service threadshang inside an entry point [1442255]In rare cases, the agent framework does not detect if all service threads hang insidea C entry point. In this case it may not cancel them successfully.

Workaround: If the service threads of the agent are hung, send a kill signal to restartthe agent. Use the following command: kill -9 hung agent's pid. The haagent-stop command does not work in this situation.

78Known IssuesCluster Server known issues

Page 79: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

IMF related error messages while bringing a resourceonline and offline [2553917]For a resource registered with AMF, if you run hagrp -offline or hagrp -online

explicitly or through a collective process to offline or online the resource respectively,the IMF displays error messages in either case.

The errors displayed is an expected behavior and it does not affect the IMFfunctionality in any manner.

Workaround: No workaround.

Delayed response to VCS commands observed on nodeswith several resources and system has high CPU usageor high swap usage [3208239]You may experience a delay of several minutes in the VCS response to commandsif you configure large number of resources for monitoring on a VCS node and if theCPU usage is close to 100 percent or swap usage is very high.

Some of the commands are mentioned below:

■ # hares -online

■ # hares -offline

■ # hagrp -online

■ # hagrp -offline

■ # hares -switch

The delay occurs as the related VCS agent does not get enough CPU bandwidthto process your command. The agent may also be busy processing large numberof pending internal commands (such as periodic monitoring of each resource).

79Known IssuesCluster Server known issues

Page 80: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Workaround: Change the values of some VCS agent type attributes which arefacing the issue and restore the original attribute values after the systemreturns to the normal CPU load.

1 Back up the original values of attributes such as MonitorInterval,OfflineMonitorInterval, and MonitorFreq of IMF attribute.

2 If the agent does not support Intelligent Monitoring Framework (IMF), increasethe value of MonitorInterval and OfflineMonitorInterval attributes.

# haconf -makerw

# hatype -modify <TypeName> MonitorInterval <value>

# hatype -modify <TypeName> OfflineMonitorInterval <value>

# haconf -dump -makero

Where <TypeName> is the name of the agent with which you are facing delaysand <value> is any numerical value appropriate for your environment.

3 If the agent supports IMF, increase the value of MonitorFreq attribute of IMF.

# haconf -makerw

# hatype -modify <TypeName> IMF -update MonitorFreq <value>

# haconf -dump -makero

Where <value> is any numerical value appropriate for your environment.

4 Wait for several minutes to ensure that VCS has executed all pendingcommands, and then execute any new VCS command.

5 If the delay persists, repeat step 2 or 3 as appropriate.

6 If the CPU usage returns to normal limits, revert the attribute changes to thebacked up values to avoid the delay in detecting the resource fault.

CFSMount agent may fail to heartbeat with VCS engineand logs an error message in the engine log on systemswith high memory load [3060779]On a system with high memory load, CFSMount agent may fail to heartbeat withVCS engine resulting into V-16-1-53030 error message in the engine log.

VCS engine must receive periodic heartbeat from CFSMount agent to ensure thatit is running properly on the system. The heartbeat is decided by AgentReplyTimeoutattribute. Due to high CPU usage or memory workload (for example, swap usagegreater than 85%), agent may not get enough CPU cycles to schedule. This causesheartbeat loss with VCS engine and as a result VCS engine terminates the agentand starts the new agent. This can be identified with the following error messagein the engine log:

80Known IssuesCluster Server known issues

Page 81: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

V-16-1-53030 Termination request sent to CFSMount

agent process with pid %d

Workaround: Increase the AgentReplyTimeout value and see if CFSMount agentbecomes stable. If this does not resolve the issue then try the following workaround.Set value of attribute NumThreads to 1 for CFSMount agent by running followingcommand:

# hatype -modify CFSMount NumThreads 1

Even after the above command if CFSMount agent keeps on terminating, reportthis to Symantec support team.

Logs from the script executed other than the agent entrypoint goes into the engine logs [3547329]The agent logs of C-based and script-based entry points get logged in the agentlog when the attribute value of LogViaHalog is set to 1 (one). To restore to the olderlogging behavior in which C-based entry point logs were logged in agent logs andscript-based entry point logs were logged in engine logs, you can set theLogViaHalog value as 0 (zero). However, it is observed that some C-based entrypoint logs continue to appear in the engine logs even when LogViaHalog is set to1 (one). This issue is observed on all the database agents.

Workaround: No workaround.

Cluster Server agents for Volume Replicator known issuesThe following are new additional Cluster Server agents for Volume Replicator knownissues in 7.0 release.

Stale entries observed in the sample main.cf file forRVGLogowner agent [2872047]Stale entries are found in sample main.cf file for RVGLogowner agent. The staleentries are present in main.cf.seattle file on the RVGLogowner agent which includesCFSQlogckd resource. However, CFSQlogckd is not supported since VCS 5.0.

Workaround: In the cvm group remove the following two lines:

CFSQlogckd qlogckd (

Critical = 0

)

81Known IssuesCluster Server known issues

Page 82: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Issues related to Intelligent Monitoring Framework (IMF)This section describes the known issues of Intelligent Monitoring Framework (IMF).

Registration error while creating a Firedrill setup [2564350]While creating the Firedrill setup using the Firedrill setup utility, VCS encountersthe following error:

AMF amfregister ERROR V-292-2-167

Cannot register mount offline event

During Firedrill operations, VCSmay log error messages related to IMF registrationfailure in the engine log. This happens because in the firedrill service group, thereis a second CFSMount resource monitoring the same MountPoint through IMF.Both the resources try to register for online/offline events on the same MountPointand as a result, registration of one fails.

Workaround: No workaround.

IMF does not provide notification for a registered diskgroup if it is imported using a different name (2730774)If a disk group resource is registered with the AMF and the disk group is thenimported using a different name, AMF does not recognize the renamed disk groupand hence does not provide notification to DiskGroup agent. Therefore, theDiskGroup agent keeps reporting the disk group resource as offline.

Workaround: Make sure that while importing a disk group, the disk group namematches the one registered with the AMF.

Direct execution of linkamf displays syntax error [2858163]Bash cannot interpret Perl when executed directly.

Workaround: Run linkamf as follows:

# /opt/VRTSperl/bin/perl /opt/VRTSamf/imf/linkamf <destination-directory>

Error messages displayed during reboot cycles [2847950]During some reboot cycles, the following message might get logged in the enginelog:

AMF libvxamf ERROR V-292-2-149 Cannot unregister event: no rid -1 found

AMF libvxamf ERROR V-292-2-306 Unable to unregister all events (errno:405)

82Known IssuesCluster Server known issues

Page 83: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

This does not have any effect on the functionality of IMF.

Workaround: No workaround.

Errormessage displayedwhenProPCVprevents a processfrom coming ONLINE to prevent concurrency violationdoes not have I18N support [2848011]The following message is seen when ProPCV prevents a process from comingONLINE to prevent concurrency violation. Themessage is displayed in English anddoes not have I18N support.

Concurrency Violation detected by VCS AMF.

Process <process-details> will be prevented from startup.

Workaround: No Workaround.

AMF displays StartProgram name multiple times on theconsole without a VCS error code or logs [2872064]When VCS AMF prevents a process from starting, it displays a message on theconsole and in syslog. The message contains the signature of the process that wasprevented from starting. In some cases, this signature might not match the signaturevisible in the PS output. For example, the name of the shell script that was preventedfrom executing will be printed twice.

Workaround: No workaround.

VCS engine shows error for cancellation of reaper whenApache agent is disabled [3043533]When haimfconfig script is used to disable IMF for one or more agents, the VCSengine logs the following message in the engine log:

AMF imf_getnotification ERROR V-292-2-193

Notification(s) canceled for this reaper.

This is an expected behavior and not an issue.

Workaround: No workaround.

Terminating the imfd daemon orphans the vxnotifyprocess [2728787]If you terminate imfd daemon using the kill -9 command, the vxnotify processcreated by imfd does not exit automatically but gets orphaned. However, if you stop

83Known IssuesCluster Server known issues

Page 84: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

imfd daemon with the amfconfig -D command, the corresponding vxnotify

process is terminated.

Workaround: The correct way to stop any daemon is to gracefully stop it with theappropriate command (which is amfconfig -D command in this case), or toterminate the daemon using Session-ID. Session-ID is the -PID (negative PID) ofthe daemon.

For example:

# kill -9 -27824

Stopping the daemon gracefully stops all the child processes spawned by thedaemon. However, using kill -9 pid to terminate a daemon is not a recommendedoption to stop a daemon, and subsequently you must kill other child processes ofthe daemon manually.

Agent cannot become IMF-aware with agent directory andagent file configured [2858160]Agent cannot become IMF-aware if Agent Directory and Agent File are configuredfor that agent.

Workaround: No workaround.

Process offline monitoring registrations through the AMFprogram freezes Cluster Server (VCS) nodes on someservice packs of AIX 7.1 and 6.1 versions [3540463]Process offline monitoring registrations with Asynchronous Monitoring Framework(AMF) freezes Cluster Server nodes on AIX 7.1 TL3 SP3 or SP4 and AIX 6.1 TL9SP3 or SP4 versions.

Workaround: Install IBM service packs AIX 6.1 TL9 SP5 or AIX 7.1 TL3 SP5 to fixthis issue. For more information, seehttps://www.veritas.com/support/en_US/article.TECH222286.

ProPCV fails to prevent a script from running if it is runwith relative path [3617014]If the absolute path is registered with AMF for prevention and the script is run withthe relative path, AMF fails to prevent the script from running.

Workaround: No workaround.

84Known IssuesCluster Server known issues

Page 85: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Issues related to global clustersThis section describes the known issues about global clusters.

The engine log file receives too many log messages onthe secure site in global cluster environments [1919933]When the WAC process runs in secure mode on one site, and the other site doesnot use secure mode, the engine log file on the secure site gets logs every fiveseconds.

Workaround: The two WAC processes in global clusters must always be started ineither secure or non-secure mode. The secure and non-secure WAC connectionswill flood the engine log file with the above messages.

Application group attempts to come online on primary sitebefore fire drill service group goes offline on the secondarysite (2107386)The application service group comes online on the primary site while the fire drillservice group attempts to go offline at the same time, causing the application groupto fault.

Workaround: Ensure that the fire drill service group is completely offline on thesecondary site before the application service group comes online on the primarysite.

Issues related to the Cluster Manager (Java Console)This section describes the known issues about Cluster Server Manager (JavaConsole).

Some Cluster Manager features fail to work in a firewallsetup [1392406]In certain environments with firewall configurations between the Cluster Managerand the VCS cluster, the Cluster Manager fails with the following error message:

V-16-10-13 Could not create CmdClient. Command Server

may not be running on this system.

Workaround: You must open port 14150 on all the cluster nodes.

85Known IssuesCluster Server known issues

Page 86: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

VCS Cluster Configuration wizard issues

IPv6 verification fails while configuring generic applicationusing VCS Cluster Configuration wizard [3614680]The VCS Cluster Configuration wizard fails to check whether IPv6 IP is alreadyplumbed while configuring a generic application through the Virtual IP page. Thewizard does neither displays a warning if IPv6 IP is already plumbed elsewhere norindicates whether it is reachable through a ping.

Workaround: Manually ensure that IPv6 is not plumbed elsewhere on the networkbefore configuring the generic application through the wizard.

LLT known issuesThis section covers the known issues related to LLT in this release.

LLT port stats sometimes shows recvcnt larger thanrecvbytes (1907228)With each received packet, LLT increments the following variables:

■ recvcnt (increment by one for every packet)

■ recvbytes (increment by size of packet for every packet)

Both these variables are integers. With constant traffic, recvbytes hits and rolls overMAX_INT quickly. This can cause the value of recvbytes to be less than the valueof recvcnt.

This does not impact the LLT functionality.

LLT over IPv6 does not work on AIX [3637948]Due to IPv6 related changes in the AIX kernel, LLT over IPv6 feature does not workon these AIX releases.

Workaround: No workaround.

I/O fencing known issuesThis section describes the known issues in this release of I/O fencing.

86Known IssuesCluster Server known issues

Page 87: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

The cpsadm command fails after upgrading CP server to6.0 or above in secure mode (2846727)The cpsadm command may fail after you upgrade coordination point server (CPserver) to 6.0 in secure mode. If the old VRTSat fileset is not removed from thesystem, the cpsadm command loads the old security libraries present on the system.As the installer runs the cpsadm command on the CP server to add or upgrade theSFCFSHA cluster (application cluster), the installer also fails.

Workaround: Perform the following procedure on all of the nodes of the CP server.

To resolve this issue

1 Rename cpsadm to cpsadmbin:

# mv /opt/VRTScps/bin/cpsadm /opt/VRTScps/bin/cpsadmbin

2 Create a file /opt/VRTScps/bin/cpsadm with the following content:

#!/bin/sh

EAT_USE_LIBPATH="/opt/VRTScps/lib"

export EAT_USE_LIBPATH

/opt/VRTScps/bin/cpsadmbin "$@"

3 Change the permissions of the new file to 775:

# chmod 755 /opt/VRTScps/bin/cpsadm

CP server repetitively logs unavailable IP addresses(2530864)If coordination point server (CP server) fails to listen on any of the IP addressesthat are mentioned in the vxcps.conf file or that are dynamically added using thecommand line, then CP server logs an error at regular intervals to indicate thefailure. The logging continues until the IP address is bound to successfully.

CPS ERROR V-97-51-103 Could not create socket for host

10.209.79.60 on port 14250

CPS ERROR V-97-1400-791 Coordination point server could not

open listening port = [10.209.79.60]:14250

Check if port is already in use.

Workaround: Remove the offending IP address from the listening IP addresseslist using the rm_port action of the cpsadm command.

87Known IssuesCluster Server known issues

Page 88: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Fencing port b is visible for few seconds even if clusternodes have not registered with CP server (2415619)Even if the cluster nodes have no registration on the CP server and if you providecoordination point server (CP server) information in the vxfenmode file of the clusternodes, and then start fencing, the fencing port b is visible for a few seconds andthen disappears.

Workaround:Manually add the cluster information to the CP server to resolve thisissue. Alternatively, you can use installer as the installer adds cluster informationto the CP server during configuration.

The cpsadm command fails if LLT is not configured on theapplication cluster (2583685)The cpsadm command fails to communicate with the coordination point server (CPserver) if LLT is not configured on the application cluster node where you run thecpsadm command. You may see errors similar to the following:

# cpsadm -s 10.209.125.200 -a ping_cps

CPS ERROR V-97-1400-729 Please ensure a valid nodeid using

environment variable

CPS_NODEID

CPS ERROR V-97-1400-777 Client unable to communicate with CPS.

However, if you run the cpsadm command on the CP server, this issue does notarise even if LLT is not configured on the node that hosts CP server. The cpsadm

command on the CP server node always assumes the LLT node ID as 0 if LLT isnot configured.

According to the protocol between the CP server and the application cluster, whenyou run the cpsadm on an application cluster node, cpsadm needs to send the LLTnode ID of the local node to the CP server. But if LLT is unconfigured temporarily,or if the node is a single-node VCS configuration where LLT is not configured, thenthe cpsadm command cannot retrieve the LLT node ID. In such situations, the cpsadmcommand fails.

Workaround: Set the value of the CPS_NODEID environment variable to 255. Thecpsadm command reads the CPS_NODEID variable and proceeds if the command isunable to get LLT node ID from LLT.

In absence of cluster details in CP server, VxFEN fails withpre-existing split-brain message (2433060)When you start server-based I/O fencing, the node may not join the cluster andprints error messages in logs similar to the following:

88Known IssuesCluster Server known issues

Page 89: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

In the /var/VRTSvcs/log/vxfen/vxfen.log file:

VXFEN vxfenconfig ERROR V-11-2-1043

Detected a preexisting split brain. Unable to join cluster.

In the /var/VRTSvcs/log/vxfen/vxfen.log file:

operation failed.

CPS ERROR V-97-1400-446 Un-authorized user cpsclient@sys1,

domaintype vx; not allowing action

The vxfend daemon on the application cluster queries the coordination point server(CP server) to check if the cluster members as seen in the GAB membership areregistered with the CP server. If the application cluster fails to contact the CP serverdue to some reason, then fencing cannot determine the registrations on the CPserver and conservatively assumes a pre-existing split-brain.

Workaround: Before you attempt to start VxFEN on the application cluster, ensurethat the cluster details such as cluster name, UUID, nodes, and privileges are addedto the CP server.

The vxfenswap utility does not detect failure ofcoordination points validation due to an RSH limitation(2531561)The vxfenswap utility runs the vxfenconfig -o modify command over RSH orSSH on each cluster node for validation of coordination points. If you run thevxfenswap command using RSH (with the -n option), then RSH does not detectthe failure of validation of coordination points on a node. From this point, vxfenswapproceeds as if the validation was successful on all the nodes. But, it fails at a laterstage when it tries to commit the new coordination points to the VxFEN driver. Afterthe failure, it rolls back the entire operation, and exits cleanly with a non-zero errorcode. If you run vxfenswap using SSH (without the -n option), then SSH detectsthe failure of validation of coordination of points correctly and rolls back the entireoperation immediately.

Workaround: Use the vxfenswap utility with SSH (without the -n option).

Fencing does not come up on one of the nodes after areboot (2573599)If VxFEN unconfiguration has not finished its processing in the kernel and in themeantime if you attempt to start VxFEN, you may see the following error in the/var/VRTSvcs/log/vxfen/vxfen.log file:

VXFEN vxfenconfig ERROR V-11-2-1007 Vxfen already configured

89Known IssuesCluster Server known issues

Page 90: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

However, the output of the gabconfig -a command does not list port b. Thevxfenadm -d command displays the following error:

VXFEN vxfenadm ERROR V-11-2-1115 Local node is not a member of cluster!

Workaround: Start VxFEN again after some time.

Common product installer cannot setup trust between aclient system on release version 5.1SP1 and a server onrelease version 6.0 or later [3226290]The issue exists because the VCS 5.1SP1 release version does not support separatedirectories for truststores. However, VCS version 6.0 and later support separatedirectories for truststores. Because of this mismatch in support for truststores, youcannot set up trust between client systems and servers.

Workaround: Set up trust manually between the coordination point server and clientsystems using the cpsat or vcsat command so that the servers and client systemscan communicate in a secure mode.

Hostname and username are case sensitive in CP server(2846392)The hostname and username on the CP server are case sensitive. The hostnameand username used by fencing to communicate with CP server must be in samecase as present in CP server database, else fencing fails to start.

Workaround: Make sure that the same case is used in the hostname and usernameon the CP server.

Server-based fencing comes up incorrectly if default portis not mentioned (2403453)When you configure fencing in customized mode and do no provide default port,fencing comes up. However, the vxfenconfig -l command output does not listthe port numbers.

Workaround: Retain the "port=<port_value>" setting in the /etc/vxfenmode file,when using customized fencing with at least one CP server. The default port valueis 14250.

Secure CP server does not connect from localhost using127.0.0.1 as the IP address (2554981)The cpsadm command does not connect to the secure CP server on the localhostusing 127.0.0.1 as the IP address

90Known IssuesCluster Server known issues

Page 91: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Workaround: Connect the secure CP server using any of the virtual IPs that isconfigured with the CP server and is plumbed on the local node.

Unable to customize the 30-second duration (2551621)When the vxcpserv process is not able to bind to an IP address during startup, itattempts to bind to that IP address at an interval of 30 seconds. This interval is notconfigurable.

Workaround: There is no workaround for this issue.

CoordPoint agent does not report the addition of new disksto a Coordinator disk group [2727672]The LevelTwo monitoring of the CoordPoint agent does not report a fault even ifthe constituent of a coordinator disk group changes due to addition of new disks inthe cooridnator disk group

Workaround: There is no workaround for this issue.

Fencing may show the RFSM state as replaying for somenodes in the cluster (2555191)Fencing based on coordination point clients in Campus cluster environment mayshow the RFSM state as replaying for some nodes in the cluster.

Workaround:

Restart fencing on the node that shows RFSM state as replaying.

The vxfenswap utility deletes comment lines from the/etc/vxfemode file, if you run the utility with hacli option(3318449)The vxfenswap utility uses RSH, SSH, or hacli protocol to communicate with peernodes in the cluster. When you use vxfenswap to replace coordination disk(s) indisk-based fencing, vxfenswap copies /etc/vxfenmode (local node) to/etc/vxfenmode (remote node).

With the hacli option, the utility removes the comment lines from the remote/etc/vxfenmode file, but, it retains comments in the local /etc/vxfenmode file.

Workaround: Copy the comments manually from local /etc/vxfenmode to remotenodes.

91Known IssuesCluster Server known issues

Page 92: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

When you configure CP server only for HTTPS-basedcommunication, the engine_A.log displays a misleadingmessage (3321101)The engine_A.log file displays the following message when you configure CPserver only for HTTPS-based communication but not for IPM-based communication.

No VIP for IPM specified in /etc/vxcps.conf

Workaround: Ignore the message.

The vxfentsthdw utility may not run on systems installedwith partial SFHA stack [3333914]The vxfentsthdw utility runs if the SFHA stack and VCS are fully installed withproperly configured SF and VxVM. It also runs if the entire SFHA stack and VCSare not installed. However, partial installs where SF is installed and configured butVCS is not installed is not supported. The utility will display an error with the -g or-c options.

Workaround: Install the VRTSvxfen fileset, then run the utility from either the installmedia or from the /opt/VRTSvcs/vxfen/bin/ location.

When a client node goes down, for reasons such as nodepanic, I/O fencing does not come up on that client nodeafter node restart (3341322)This issue happens when one of the following conditions is true:

■ Any of the CP servers configured for HTTPS communication goes down.

■ The CP server service group in any of the CP servers configured for HTTPScommunication goes down.

■ Any of the VIPs in any of the CP servers configured for HTTPS communicationgoes down.

When you restart the client node, fencing configuration starts on the node. Thefencing daemon, vxfend, invokes some of the fencing scripts on the node. Each ofthese scripts has a timeout value of 120 seconds. If any of these scripts fails, fencingconfiguration fails on that node.

Some of these scripts use cpsadm commands to communicate with CP servers.When the node comes up, cpsadm commands try to connect to the CP server usingVIPs for a timeout value of 60 seconds. So, if the multiple cpsadm commands thatare run within a single script exceed the timeout value, then the total timeout value

92Known IssuesCluster Server known issues

Page 93: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

exceeds 120 seconds, which causes one of the scripts to time out. Hence, I/Ofencing does not come up on the client node.

Note that this issue does not occur with IPM-based communication between CPserver and client clusters.

Workaround: Fix the CP server.

The vxfenconfig -l command output does not listCoordinator disks that are removed using the vxdmpadmexclude dmpnodename=<dmp_disk/node> command[3644431]After you remove a Coordinator disk used by fencing or fencing disk group byrunning the vxdmpadm exclude dmpnodename=<dmp_disk/node> command, theremoved disk is not listed in the vxfenconfig -l command output.

In case of a split brain, the vxfen program cannot use the removed disk as acoordination point in the subsequent fencing race.

Workaround: Run the vxdmpadm include dmpnodename=<dmp_disk/node>

command to again enable the dmp disk. This disk will show up in subsequentvxfencondig -l output.

Coordination point server-based fencing may fail if it isconfigured on 5.1SP1RP1 using 6.0.1 coordination pointservers (3226290)The 5.1SP1 installer (CPI) cannot set up trust between a 5.1SP1 client and a 6.0or later server, because there are no separate directories for truststores in the5.1SP1. When trust cannot be setup, the 5.1SP1 installer cannot configure 5.1SP1clients to work with 6.0 or later CPS in secure mode.

Workaround:

Set up trust manually between the CPS and clients using the cpsat or the vcsatcommand. After that, CPS and client will be able to communicate properly in thesecure mode.

The CoordPoint agent faults after you detach or reattachone or more coordination disks from a storage array(3317123)After you detach or reattach a coordination disk from a storage array, the CoordPointagent may fault because it reads an older value stored in the I/O fencing kernelmodule.

93Known IssuesCluster Server known issues

Page 94: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Workaround: Run the vxfenswap utility to refresh the registration keys on thecoordination points for both server-based I/O fencing and disk-based I/O fencing.But, even if the registrations keys are not lost, you must run the vxfenswap utilityto refresh the coordination point information stored in the I/O fencing kernel module.

For more information on refreshing registration keys on the coordination points forserver-based and disk-based I/O fencing, refer to theCluster Server Administrator’sGuide.

The upper bound value of FaultTolerance attribute ofCoordPoint agent should be less than the majority of thecoordination points. (2846389)The upper bound value of FaultTolerance attribute of CoordPoint agent shouldbe less than the majority of the coordination points. Currently this value is less thanthe number of coordination points.

The vxfenswap utility deletes comment lines from the/etc/vxfemode file, if you run the utility with hacli option(3318449)The vxfenswap utility uses RSH, SSH, or hacli protocol to communicate with peernodes in the cluster. When you use vxfenswap to replace coordination disk(s) indisk-based fencing, vxfenswap copies /etc/vxfenmode (local node) to/etc/vxfenmode (remote node).

With the hacli option, the utility removes the comment lines from the remote/etc/vxfenmode file, but, it retains comments in the local /etc/vxfenmode file.

Workaround: Copy the comments manually from local /etc/vxfenmode to remotenodes.

GAB known issuesThis section covers the known issues related to GAB in this release.

While deinitializing GAB client, "gabdebug -RGabTestDriver" command logs refcount value 2 (2536373)After you unregister the gtx port with -nodeinit option, the gabconfig -C commandshows refcount as 1. But when forceful deinit option (gabdebug -R

GabTestDriver) is run to deinitialize GAB client, then a message similar to thefollowing is logged.

94Known IssuesCluster Server known issues

Page 95: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

GAB INFO V-15-1-20239

Client GabTestDriver with refcount 2 forcibly deinited on user request

The refcount value is incremented by 1 internally. However, the refcount value isshown as 2 which conflicts with the gabconfig -C command output.

Workaround: There is no workaround for this issue.

Cluster panics during reconfiguration (2590413)While a cluster is reconfiguring, GAB broadcast protocol encounters a race conditionin the sequence request path. This condition occurs in an extremely narrow windowwhich eventually causes the GAB master to panic.

Workaround: There is no workaround for this issue.

Storage Foundation and High Availability knownissues

This section describes the known issues in this release of Storage Foundation andHigh Availability (SFHA). These known issues apply to Veritas InfoScale Enterprise.

Cache area is lost after a disk failure (3158482)SmartIO supports one VxFS cache area and one VxVM cache area. If you createone cache area, and the disk fails, the cache area becomes disabled. If you attemptto create a second cache area of the other type before the cache disk group isenabled, then the first cache area is lost. It cannot be brought online.

For example, first you created a VxFS cache area. The disk failed and the cachearea is disabled. Now create the VxVM cache area. While creating VxVM cachearea, SmartIO looks for an existing default cache area. Due to the failed disk, theexisting cache area cannot be found. So SmartIO creates a VxVM cache area withthe same name. Now even if disk containing VxFS cache area comes up, SmartIOcannot access the original cache area. In this scenario, the VxFS cache area islost. Losing the cache area in this case does not result into any data loss or datainconsistency issues.

Workaround:

Create a new VxFS cache area.

95Known IssuesStorage Foundation and High Availability known issues

Page 96: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

In an IPv6 environment, db2icrt and db2idrop commands return asegmentation fault error during instance creation and instanceremoval (1602444)

When using IBM DB2 db2icrt command to create a DB2 database instance on apure IPv6 environment, the db2icrt command returns segmentation fault errormessage. For example:

$ /opt/ibm/db2/V9.5/instance/db2icrt -a server -u db2fen1 db2inst1

/opt/ibm/db2/V9.5/instance/db2iutil: line 4700: 26182 Segmentation fault

$ {DB2DIR?}/instance/db2isrv -addfcm -i ${INSTNAME?}

The db2idrop command also returns segmentation fault, but the instance is removedsuccessfully after the db2idrop command is issued. For example:

$ /opt/ibm/db2/V9.5/instance/db2idrop db2inst1

/opt/ibm/db2/V9.5/instance/db2iutil: line 3599: 7350 Segmentation fault

$ {DB2DIR?}/instance/db2isrv -remove -s DB2_${INSTNAME?} 2> /dev/null

DBI1070I Program db2idrop completed successfully.

This happens on DB2 9.1, 9.5, and 9.7.

This issue has been identified as an IBM issue. Once IBM has fixed this issue, thenIBM will provide a hotfix for this segmentation problem.

At this time, you can communicate in a dual-stack to avoid the segmentation faulterror message until IBM provides a hotfix.

To communicate in a dual-stack environment

◆ Add an IPv6 hostname as an IPv4 loopback address to the /etc/hosts file.For example:

127.0.0.1 swlx20-v6

Or

127.0.0.1 swlx20-v6.punipv6.com

127.0.0.1 is the IPv4 loopback address.

swlx20-v6 and swlx20-v6.punipv6.com are the IPv6 hostnames.

Oracle 11gR1 may not work on pure IPv6 environment (1819585)There is problem running Oracle 11gR1 on a pure IPv6 environment.

Running AIX 6.1, you may receive the following error message when using sqlplus:

96Known IssuesStorage Foundation and High Availability known issues

Page 97: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

$ sqlplus " / as sysdba"

SQL> startup nomount

SQL> ORA 0-0-0-0

Workaround: There is no workaround for this, as Oracle 11gR1 does not fullysupport pure IPv6 environment. Oracle 11gR2 release may work on a pure IPv6enviroment, but it has not been tested or released yet.

Not all the objects are visible in the VOM GUI (1821803)After upgrading SF stack from 5.0MP3RP2 to 5.1, the volumes are not visible underthe Volumes tab and the shared diskgroup is discovered as Private and Deportedunder the Diskgroup tab in the VOM GUI.

Workaround:

To resolve this known issue

◆ On each manage host where VRTSsfmh 2.1 is installed, run:

# /opt/VRTSsfmh/adm/dclisetup.sh -U

An error message is received when you perform off-host clone forRAC and the off-host node is not part of the CVM cluster (1834860)

There is a known issue when you try to perform an off-host clone for RAC and theoff-host node is not part of the CVM cluster. You may receive a similar errormessage:

Cannot open file /etc/vx/vxdba/rac11g1/.DB_NAME

(No such file or directory).

SFORA vxreptadm ERROR V-81-8847 Cannot get filename from sid

for 'rac11g1', rc=-1.

SFORA vxreptadm ERROR V-81-6550 Could not connect to repository

database.

VxVM vxdg ERROR V-5-1-582 Disk group SNAP_rac11dg1: No such disk

group SFORA

vxsnapadm ERROR V-81-5623 Could not get CVM information for

SNAP_rac11dg1.

SFORA dbed_vmclonedb ERROR V-81-5578 Import SNAP_rac11dg1 failed.

Workaround: Currently there is no workaound for this known issue. However, ifthe off-host node is part of the CVM cluster, then off-host clone for RAC works fine.

97Known IssuesStorage Foundation and High Availability known issues

Page 98: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Also the dbed_vmclonedb command does not support LOCAL_LISTENER andREMOTE_LISTENER in the init.ora parameter file of the primary database.

A volume's placement class tags are not visible in the VeritasEnterprise Administrator GUI when creating a SmartTier placementpolicy (1880081)

A volume's placement class tags are not visible in the Veritas EnterpriseAdministrator (VEA) GUI when you are creating a SmartTier placement policy ifyou do not tag the volume with the placement classes prior to constructing a volumeset for the volume.

Workaround: To see the placement class tags in the VEA GUI, you must tag thevolumes prior to constructing the volume set. If you already constructed the volumeset before tagging the volumes, restart vxsvc to make the tags visible in the GUI.

Upgrading operating system Technology Levels along with StorageFoundation using an alternate disk fails (2162945)

Upgrading the operating system Technology Levels (TL) along with StorageFoundation using an alternate disk fails occasionally with the following error:

alt_disk_copy: 0505-224 ATTENTION:

An error occurred during installation of

one or more software components.

Modifying ODM on cloned disk.

Building boot image on cloned disk.

forced unmount of /alt_inst/var/adm/ras/platform

forced unmount of /alt_inst/var

umount: error unmounting /dev/alt_hd2: Device busy

0505-144 alt_disk_install: Unable to unmount alt_inst filesystems.

No issues have been observed with Storage Foundation in the cause of the failure.

Storage Foundation Cluster File System HighAvailability known issues

This section describes the known issues in this release of Storage FoundationCluster File System High Availability (SFCFSHA). These known issues apply to thefollowing products:

■ Veritas InfoScale Storage

98Known IssuesStorage Foundation Cluster File System High Availability known issues

Page 99: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

■ Veritas InfoScale Enterprise

Write back cache is not supported on the cluster in FSS scenario[3723701]

Write back cache is not supported in FSS scenario on Cluster file system. Whenthe Write back is enabled, for example, node N1 and N2 both have its own SSDand they are using each other's SSD as remote cache. Then it may cause datacorruption and the recovery is not possible on cluster.

Workaround: This issue has been fixed.

CVMVOLDg agent is not going into the FAULTED state. [3771283]In CVMVOLDg monitor script we are not able to parse a variable and hence thevolume does not go into the disabled state. This is the reason why the CVMVOLDgagent is not going into the FAULTED state.

Workaround:

Enable CVMVOLIOTEST on the volume for the resource to go into FAULTED state,using the following commands:

# haconf -makerw

# hares -modify test_vol_dg CVMVolumeIoTest testvol

# haconf -dump -makero

CFS commands might hang when run by non-root (3038283)The CFS commands might hang when run by non-root.

Workaround

To resolve this issue

◆ Use halogin command to save the authentication information before runningany CFS commands on a non-root session.

When you run the halogin command, VCS stores encrypted authenticationinformation in the user’s home directory.

99Known IssuesStorage Foundation Cluster File System High Availability known issues

Page 100: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Inode access and modification times are not getting updated on theprimary node when a file owned by the primary node is accessedfrom a secondary node (2170318)

The inode access times and inode modification itimes (collectively known as itimes)are not getting updated on the primary node when a file owned by the primary nodeis accessed from a secondary node. The primary node has a stale value for thoseitimes. A cluster file system requires consistent itimes on all the nodes at the sametime. The system performance has aminimal impact even if itimes are not the sameon all nodes.

Workaround: There is no workaround for this issue.

The fsappadm subfilemove command moves all extents of a file(3258678)

This issue occurs under following conditions:

■ You run the fsppadm subfilemove command from a cluster file system (CFS)secondary node.

■ You specify a range of extents for relocation to a target tier.

If the extent size is greater than or equal to 32768, the fsppadm subfilemove

command moves all extents of the specified table to the target tier. The expectationis to move a specified range of extents.

Workaround:

◆ On the CFS primary node, determine the primary node using one of thefollowing commands:

# fsclustadm showprimary mountpoint

# fsclustadm idtoname nodeid

Certain I/O errors during clone deletion may lead to system panic.(3331273)

Certain I/O errors during clone deletion may lead to system panic.

Workaround:

There is no workaround for this issue.

100Known IssuesStorage Foundation Cluster File System High Availability known issues

Page 101: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Panic due to null pointer de-reference in vx_bmap_lookup()(3038285)

If you use the fsadm -b command on a CFS secondary node to resize the filesystem, it might fail with the following error message printed in the syslog:

Reorg of inode with shared extent larger than 32768 blocks

can be done only on the CFS Primary node

Workaround: Resize the file system with the fsadm command from the primarynode of the cluster.

In a CFS cluster, that has multi-volume file system of a small size,the fsadm operation may hang (3348520)

In a CFS cluster, that has multi-volume file system of a small size, the fsadmoperation may hang, when the free space in the file system is low.

Workaround: There is no workaround for this issue.

Storage Foundation for Oracle RAC known issuesThis section describes the known issues in this release of Storage Foundation forOracle RAC (SFRAC). These known issues apply to Veritas InfoScale Enterprise.

Oracle RAC known issuesThis section lists the known issues in Oracle RAC.

Oracle Grid Infrastructure installationmay fail with internaldriver errorThe Oracle Grid Infrastructure installation may fail with the following error:

[INS-20702] Unexpected Internal driver error

Workaround:

Export the OUI_ARGS environment variable, before you run the SF Oracle RACinstallation program:

export OUI_ARGS=-ignoreInternalDriverError

For more information, see the Oracle Metalink document: 970166.1

101Known IssuesStorage Foundation for Oracle RAC known issues

Page 102: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

During installation or system startup, Oracle GridInfrastructure may fail to startAfter successful installation of Oracle RAC 11g Release 2 Grid Infrastructure, whileexecuting the root.sh script, ohasdmay fail to start. Similarly, during system startup,Oracle Grid Infrastructure may fail to start though the VCS engine logs may indicatethat the cssd resource started Oracle Grid Infrastructure successfully.

For possible causes and workarounds, see the Oracle Metalink document:1069182.1

Node fails to join the cluster after installation or upgradeto specific operating system versionsAfter you install or upgrade to operating system versions AIX 6.1 TL8 or 7.1 TL2with Oracle RAC 11g Release 2 and later versions, Oracle Clusterware successfullystarts on only one node in the cluster. The remaining nodes fail to join the clusteras the daemons CRSD and EVMD are in an intermediate state. For moreinformation, see the metalink document: 1528452.1

Workaround: Install the following AIX HIPER efixes:

AIX 6.1 TL08 SP01 - APAR IV35888

AIX 7.1 TL02 SP01 - APAR IV35893

Storage Foundation Oracle RAC issuesThis section lists the known issues in SF Oracle RAC for this release.

ASM disk groups configured with normal or highredundancy are dismounted if the CVMmaster panics dueto network failure in FSS environment or if CVM I/Oshipping is enabled (3600155)Disk-level remote write operations are paused during reconfiguration for longerthan the default ASM heartbeat I/O wait time in the following scenarios:

■ CVM master node panics

■ Private network failure

As a result, the ASM disk groups get dismounted.

Workaround: See to the Oracle metalink document: 1581684.1

102Known IssuesStorage Foundation for Oracle RAC known issues

Page 103: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

PrivNIC andMultiPrivNIC agents not supportedwithOracleRAC 11.2.0.2 and later versionsThe PrivNIC and MultiPrivNIC agents are not supported with Oracle RAC 11.2.0.2and later versions.

For more information, see the following Technote:

https://www.veritas.com/support/en_US/article.TECH145261

CSSD agent forcibly stops Oracle Clusterware if OracleClusterware fails to respond (3352269)On nodes with heavy load, the CSSD agent attempts to check the status of OracleClusterware till it reaches theFaultOnMonitorTimeouts value. However, OracleClusterware fails to respond and the CSSD agent forcibly stops Oracle Clusterware.To prevent the CSSD agent from forcibly stopping Oracle Clusterware, set the valueof the FaultOnMonitorTimeouts attribute to 0 and use theAlertOnMonitorTimeouts attribute as described in the following procedure.

Perform the following steps to prevent the CSSD agent from forcibly stoppingOracle Clusterware:

1 Change the permission on the VCS configuration file to read-write mode:

# haconf -makerw

2 Set the AlertOnMonitorTimeouts attribute value to 4 for the CSSD resource:

# hatype -display CSSD | grep AlertOnMonitorTimeouts

CSSD AlertOnMonitorTimeouts 0

# hares -override cssd_resname AlertOnMonitorTimeouts

# hatype -modify CSSD AlertOnMonitorTimeouts 4

3 Set the FaultOnMonitorTimeouts attribute value to 0 for the CSSD resource:

# hatype -display CSSD | grep FaultOnMonitorTimeouts

CSSD FaultOnMonitorTimeouts 4

# hares -override cssd_resname FaultOnMonitorTimeouts

# hatype -modify CSSD FaultOnMonitorTimeouts 0

103Known IssuesStorage Foundation for Oracle RAC known issues

Page 104: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

4 Verify the AlertOnMonitorTimeouts and FaultOnMonitorTimeouts settings:

# hatype -display CSSD | egrep \

"AlertOnMonitorTimeouts|FaultOnMonitorTimeouts"

CSSD AlertOnMonitorTimeouts 4

CSSD FaultOnMonitorTimeouts 0

5 Change the permission on the VCS configuration file to read-only mode:

# haconf -dump -makero

Intelligent Monitoring Framework (IMF) entry point mayfail when IMF detects resource state transition from onlineto offline for CSSD resource type (3287719)When IMF detects a state transition fromONLINE to OFFLINE state for a registeredonline resource, it sends a notification to the CSSD agent. The CSSD agentschedules a monitor to confirm the state transition of the resource. The resourcesof type CSSD takes more time to go online or offline fully. Therefore, if this immediatemonitor finds the resource still in online state, it assumes that the IMF notificationis false and attempts to register the resource in online state again.

In such partial state transitions, the agent repeatedly attempts to register theresource until theRegisterRetryLimit is reached (default value is 3) or the resourceregistration is successful. After the resource is completely offline, the next resourceregistration with IMF will be successful.

Workaround: Increase the value of the RegisterRetryLimit attribute if multipleregistration attempts fail.

Process offline monitoring issues with AsynchronousMonitoring Framework [3540463]Process offline monitoring registrations with Asynchronous Monitoring Framework(AMF) freezes Symantec Cluster Server nodes on AIX 7.1 TL3 SP3/SP4 and AIX6.1 TL9 SP3/SP4 versions.

Workaround: Install the IBM APAR IV63274 on all nodes to fix this issue.

Node fails to join the SF Oracle RAC cluster if the filesystem containing Oracle Clusterware is not mounted(2611055)The sequence number of the startup script for Oracle High Availability Servicesdaemon (ohasd) is lower than some of the SF Oracle RAC components such as

104Known IssuesStorage Foundation for Oracle RAC known issues

Page 105: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

VXFEN and VCS. During system startup, if the file system containing OracleClusterware does not get mounted before the ohasd startup script is executed, thescript continuously waits for the file system to become available. As a result, theother scripts (including those of SF Oracle RAC components) are not executed andthe node being started does not join the SF Oracle RAC cluster.

Workaround: If the rebooted node does not join the SF Oracle RAC cluster, thecluster can be started manually using the following command:

# installer -start node1 node2

The vxconfigd daemon fails to start after machine reboot(3566713)The shutdown -r commandmakes sure that the file contents on the OS file systemare written properly to the disk before a reboot. The volboot file is created in theOS file system, and is used to bring up the vxconfigd daemon after the systemreboot. If the machine reboots for any reason without proper shutdown, and thevolboot file contents are not flushed to the disk, vxconfigd will not start after thesystem reboots.

Workaround:

You must rerun the vxinstall script to re-create the volboot file and to start thevxconfigd daemon and other daemons.

Health check monitoring fails with policy-manageddatabases (3609349)The health check option of the Cluster Server agent for Oracle fails to determinethe status of the Oracle resource in policy-managed database environments. Thisis because the database SID is dynamically created during the time of the healthcheck as a result of which the correct SID is not available to retrieve the resourcestatus.

Issue with format of the last 8-bit number in private IPaddresses (1164506)The PrivNIC/MultiPrivNIC resources fault if the private IP addresses have a leading0 in any of the octets that comprise the IP address, for example X.X.X.01 orX.X.0X.1. or X.0X.X.1 or 0X.X.X.1, where X is an octet of the IP address.

When you configure private IP addresses for Oracle Clusterware, ensure that theIP addresses have a format as displayed in the following two-node example:

■ On galaxy: 192.168.12.1

105Known IssuesStorage Foundation for Oracle RAC known issues

Page 106: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

■ On nebula: 192.168.12.2

Confirm the correct format by viewing the PrivNIC or MultiPrivNIC resource in the/etc/VRTSvcs/conf/config/main.cf file.

CVMVolDg agent may fail to deport CVM disk groupThe CVM disk group is deported based on the order in which the CVMVolDgresources are taken offline. If the CVMVolDg resources in the disk group containa mixed setting of 1 and 0 for the CVMDeportOnOffline attribute, the disk group isdeported only if the attribute value is 1 for the last CVMVolDg resource taken offline.If the attribute value is 0 for the last CVMVolDg resource taken offline, the diskgroup is not deported.

Workaround: If multiple CVMVolDg resources are configured for a shared diskgroup, set the value of the CVMDeportOnOffline attribute to 1 for all of the resources.

Veritas VolumeManager can not identify Oracle AutomaticStorage Management (ASM) disks (2771637)Veritas VolumeManager (VxVM) commands can not identify disks that are initializedby ASM. Administrators must use caution when using the VxVM commands to avoidaccidental overwriting of the ASM disk data.

CVM requires the T10 vendor provided ID to be unique(3191807)For CVM to work, each physical disk should generate a unique identifier (UDID).The generation is based on the T10 vendor provided ID on SCSI-3 vendor productdescriptor (VPD) page 0x83. In some cases, the T10 vendor provided ID on SCSI-3VPD page 0x83 is the same for multiple devices, which violates the SCSI standards.CVM configurations should avoid using such disks.

You can identify the T10 vendor provided ID using the following command:

# sq_inq --page=0x83 /dev/diskname

On VxVM you can identify the T10 vendor provided ID using the following command:

# /etc/vx/diag.d/vxscsiinq -e 1 -p 0x83 /dev/vx/rdmp/diskname

You can verify the VxVM generated UDID on the disk using the following command:

# vxdisk list diskname | grep udid

106Known IssuesStorage Foundation for Oracle RAC known issues

Page 107: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Preserving Flexible Storage Sharing attributes withvxassist grow and vxresize commands is not supported(3225318)Preservation of FSS attributes using vxasssist grow and vxresize is notsupported. FSS attributes include the attributes that are specified on the commandline as well as the attributes implicitly assumed for FSS disk groups. These attributesare not reused with further vxassist orpations on the volume such as the growby

and the vxresize commands.

Workaround:

There is no workaround for this issue.

FSS Disk group creation with 510 exported disks frommaster fails with Transaction locks timed out error(3311250)Flexible Storage Sharing (FSS) Disk group creation for local disks that are exportedmay fail if the number of disks used for disk group creation is greater than 150, withthe following error message:

VxVM vxdg ERROR V-5-1-585 Disk group test_dg: cannot create: Transaction

locks timed out

A similar error can be seen while adding more that 150 locally exported disks (withvxdg adddisk ) to the FSS disk group, with the following error message:

VxVM vxdg ERROR V-5-1-10127 associating disk-media emc0_0839 with emc0_0839:

Transaction locks timed out

Workaround:

Create an FSS disk group using 150 or less locally exported disks and then do anincremental disk addition to the disk group with 150 or less locally exported disksat a time.

Change in naming scheme is not reflected on nodes in anFSS environment (3589272)In a Flexible Storage Sharing (FSS) environment, if you change the naming schemeon a node that has local disks, the remote disk names are not reflected with thecorresponding name change. If you change the naming scheme on a node whereexported disks are present, to reflect the updated remote disk names, you musteither export the disks again or restart the node where the remote disks are present

Workaround:

107Known IssuesStorage Foundation for Oracle RAC known issues

Page 108: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

There is no workaround for this issue.

vxassist does not create data change logs on all mirroreddisks, if an FSS volume is created using DM lists (3559362)When a Flexible Storage Sharing (FSS) volume is created using DM lists, thevxassist command does not create data change logs on all the mirrored disks;the number of DCOmirrors is not equal to the number of data mirrors. The vxassistcommand creates a two-way DCO volume.

Workaround:

Manually add a DCOmirror using the vxassist -g diskgroup mirror dco_volume

command.

Storage Foundation for Databases (SFDB) toolsknown issues

This section describes the known issues in this release of Storage Foundation forDatabases (SFDB) tools.

Sometimes SFDB may report the following error message: SFDBremote or privileged command error (2869262)

While using SFDB tools, if you attempt to run commands, such as dbed_updatethen you may observe the following error:

$ /opt/VRTSdbed/bin/dbed_update

No repository found for database faildb, creating new one.

SFDB vxsfadm ERROR V-81-0450 A remote or privileged command could not

be executed on swpa04

Reason: This can be caused by the host being unreachable or the vxdbd

daemon not running on that host.

Action: Verify that the host swpa04 is reachable. If it is, verify

that the vxdbd daemon is running using the /opt/VRTS/bin/vxdbdctrl

status command, and start it using the /opt/VRTS/bin/vxdbdctrl start

command if it is not running.

Workaround: There is no workaround for this issue.

108Known IssuesStorage Foundation for Databases (SFDB) tools known issues

Page 109: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

SFDB commands do not work in IPV6 environment (2619958)In IPV6 environment, SFDB commands do not work for SF, SFCFSHA, SFHA orSFRAC.

Workaround:

There is no workaround at this point of time.

The database clone operation using the vxsfadm -o clone(1M)command fails (3313715)

In an Oracle RAC environment, while you try to bring up a cloned database instanceon a remote RAC node using the SECONDARY_HOSTparameter in snapshotconfiguration, the database clone operation fails. Additionally, the following errormessage occurs:

[oracle@rac-v01 ~]$ vxsfadm -s flashsnap -a oracle -o clone

--flashsnap_name sn115 --clone_path /cloneoracle --clone_name cln709

--secondary_host rac-v02

SFDB vxsfadm ERROR V-81-0602 Remote execution failed:

SFDB vxsfadm ERROR V-81-0000 Another instance of vxsfadm is running

Workaround: Avoid using the SECONDARY_HOST parameter in a snapshotconfiguration. Additionally, perform the cloning operation locally on the RAC nodewhere you need the cloned instance to be brought up.

In an off-host scenario, a clone operation may fail with an errormessage (3313572)

A clone operation may fail with the following error due to restricted process resourcelimits in effect for the root user.

ORA-00283: recovery session canceled due to errors

ORA-01110: data file 5: '/flash_snap/oracle/oradata/run/soe.dbf'

ORA-01157: cannot identify/lock data file 5 - see DBWR trace file

ORA-01110: data file 5: '/flash_snap/oracle/oradata/run/soe.dbf'

All off-host operations especially the clone operations are routed through the vxdbddaemon, which is currently unable to support the per-user process resource limitsthat are set for the non-root users. Thus, all operations that are routed throughvxdbd, inherit the resource limits set for the root user. If these limits are restrictive,then the operation may fail.

109Known IssuesStorage Foundation for Databases (SFDB) tools known issues

Page 110: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Workaround: Set the resource limit for the root user to a maximum range suchthat it is close to the Oracle database’s requirement.

When you attempt to move all the extents of a table, thedbdst_obj_move(1M) command fails with an error (3260289)

When you attempt to move all the extents of a database table, which is spreadacross multiple mount-points in a single operation, the dbdst_obj_move(1M)

command fails. The following error is reported:

bash-2.05b$ dbdst_obj_move -S sdb -H $ORACLE_HOME -t test3 -c MEDIUM

FSPPADM err : UX:vxfs fsppadm: WARNING: V-3-26543: File handling failure

on /snap_datadb/test03.dbf with message -

SFORA dst_obj_adm ERROR V-81-6414 Internal Error at fsppadm_err

Note: To determine if the table is spread across multiple mount-points, run thedbdst_obj_view(1M) command

Workaround: In the dbdst_obj_move(1M) command, specify the range of extentsthat belong to a common mount-point. Additionally, if your table is spread across"n" mount-points, then you need to run the dbdst_obj_move(1M) command "n"times with a different range of extents.

Attempt to use SmartTier commands fails (2332973)The attempts to run SmartTier commands such as dbdst_preset_policyordbdst_file_move fail with the following error:

fsppadm: ERROR: V-3-26551: VxFS failure on low level mechanism

with message - Device or resource busy

This error occurs if a sub-file SmartTier command such as dbdst_obj_move hasbeen previously run on the file system.

Workaround: There is no workaround for this issue. You cannot use file-basedSmartTier and sub-file SmartTier simultaneously.

Attempt to use certain names for tiers results in error (2581390)If you attempt to use certain names for tiers, the following error message isdisplayed:

SFORA dbdst_classify ERROR V-81-6107 Invalid Classname BALANCE

110Known IssuesStorage Foundation for Databases (SFDB) tools known issues

Page 111: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

This error occurs because the following names are reserved and are not permittedas tier names for SmartTier:

■ BALANCE

■ CHECKPOINT

■ METADATA

Workaround: Use a name for SmartTier classes that is not a reserved name.

Clone operation failure might leave clone database in unexpectedstate (2512664)

If the clone operation fails, it may leave the clone database in an unexpected state.Retrying the clone operation might not work.

Workaround:

If retrying does not work, perform one the following actions depending on thepoint-in-time copy method you are using:

■ For FlashSnap, resync the snapshot and try the clone operation again.

■ For FileSnap and Database Storage Checkpoint, destroy the clone and createthe clone again.

■ For space-optimized snapshots, destroy the snapshot and create a newsnapshot.

Contact Symantec support if retrying using the workaround does not succeed.

Clone command fails if PFILE entries have their values spread acrossmultiple lines (2844247)

If you have a parameter, such as log_archive_dest_1, in single line in theinit.ora file, then dbed_vmclonedb works but dbed_vmcloneb fails if you put inmultiple lines for parameter.

Workaround:Edit the PFILE to arrange the text so that the parameter values areon a single line. If the database uses a spfile and some parameter values are spreadacross multiple lines, then use the Oracle commands to edit the parameter valuessuch as they fit in a single line.

111Known IssuesStorage Foundation for Databases (SFDB) tools known issues

Page 112: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Clone fails with error "ORA-01513: invalid current time returned byoperating system" with Oracle 11.2.0.3 (2804452)

While creating a clone database using any of the point-in-time copy services suchas Flashsnap, SOS, Storage Checkpoint, or Filesnap, the clone fails. This problemappears to affect Oracle versions 11.2.0.2 as well as 11.2.0.3.

You might encounter an Oracle error such as the following:

/opt/VRTSdbed/bin/vxsfadm -s flashsnap -o clone

-a oracle -r dblxx64-16-v1 --flashsnap_name TEST11 --clone_path

/tmp/testRecoverdb --clone_name clone1

USERNAME: oragrid

STDOUT:

Retrieving snapshot information ... Done

Importing snapshot diskgroups ... Done

Mounting snapshot volumes ... Done

ORA-01513: invalid current time returned by operating system

This is a known Oracle bug documented in the following Oracle bug IDs:

■ Bug 14102418: DATABASE DOESNT START DUE TO ORA-1513

■ Bug 14036835: SEEING ORA-01513 INTERMITTENTLY

Workaround: Retry the cloning operation until it succeeds.

Data population fails after datafile corruption, rollback, and restoreof offline checkpoint (2869259)

Sometimes when a datafile gets corrupted below its reservation size, the rollbackmay not pass and the file may not be rolled back correctly.

There is no workround at this point of time.

FileSnap detail listing does not display the details of a particular snap(2846382)

FileSnap does not support displaying a detailed listing of a snapshot or clone.FileSnap only supports displaying a summary of all the snapshots or clones. Forexample, for the CLI vxsfadm -s filesnap -a oracle --name=snap1 -o list,a summary listing all the snapshots is displayed, instead of a detailed listing of aparticular snapshot.

Workaround: There is no workaround for this issue.

112Known IssuesStorage Foundation for Databases (SFDB) tools known issues

Page 113: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Flashsnap clone fails under some unusual archivelog configurationon RAC (2846399)

In a RAC environment, when using FlashSnap, the archive log destination tosnapshot must be a shared path, and must be the same across all the nodes.Additionally, all nodes must use the same archive log configuration parameter tospecify the archive log destination. Configurations similar to the following are notsupported:

tpcc1.log_archive_dest_1='location=/tpcc_arch'

tpcc2.log_archive_dest_2='location=/tpcc_arch'

tpcc3.log_archive_dest_3='location=/tpcc_arch'

Where tpcc1, tpcc2, and tpcc3 are the names of the RAC instances and /tpcc_archis the shared archive log destination.

Workaround: To use FlashSnap, modify the above configuration to*.log_archive_dest_1='location=/tpcc_arch'. For example,

tpcc1.log_archive_dest_1='location=/tpcc_arch'

tpcc2.log_archive_dest_1='location=/tpcc_arch'

tpcc3.log_archive_dest_1='location=/tpcc_arch'

Database Storage Checkpoints created by using dbed_ckptcreatemay not be visible after upgrading to 7.0 (2626248)

After upgrading from a 5.0 release to 7.0, the Database Storage Checkpoints createdearlier using dbed_ckptcreate may not be migrated.

Workaround: Perform the following steps to make the old Database StorageCheckpoints visible.

To resolve the issue

1 Remove the new repository.

■ Examine the contents of the /var/vx/vxdba/rep_locfile to determine thelocation of the 7.0 repository.

■ Remove the .sfae directory specified as the location attribute.

2 Remove the repository location file: /var/vx/vxdba/rep_loc.

113Known IssuesStorage Foundation for Databases (SFDB) tools known issues

Page 114: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

3 Create a symlink /var/vx/vxdba/<SID>/.sfdb_rept pointing to the.sfdb_rept directory created in the same location as the .sfae directoryremoved earlier.

$ ln -s <location>/.sfdb_rept /var/vx/vxdba/<SID>/.sfdb_rept

This step creates a symlink to the old repository.

4 Import repository data by running the dbed_update command.

This step imports the data from the old repository.

The old Database Storage Checkpoints are now visible.

Cloning of a container database may fail after a reverse resynccommit operation is performed (3509778)

After a reverse resync operation is performed, the cloning of a container databasemay fail with the following error message:

SFDB vxsfadm ERROR V-81-0564 Oracle returned error.

Reason: ORA-01503: CREATE CONTROLFILE failed

ORA-01189: file is from a different RESETLOGS than previous files

ORA-01110: data file 6: '/tmp/testRecoverdb/data/sfaedb/users01.dbf'

Workaround: There is no workaround for this issue.

If one of the PDBs is in the read-write restricted state, then cloningof a CDB fails (3516634)

Cloning a container database (CDB) for point-in-time copies fails if some of thepluggable databases (PDBs) are open in the restricted mode. The failure occurswith the following error message:

SFDB vxsfadm ERROR V-81-0564 Oracle returned error.

Reason: ORA-65106: Pluggable database #3 (PDB1) is in an invalid state.

Workaround: There is no workaround for this issue.

114Known IssuesStorage Foundation for Databases (SFDB) tools known issues

Page 115: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Cloning of a CDB fails for point-in-time copies when one of the PDBsis in the read-only mode (3513432)

For Oracle version 12.1.0.1, cloning a container database (CDB) fails if one of thepluggable databases (PDBs) is in the read-only mode. The failure occurs with thefollowing error message:

SFDB vxsfadm ERROR V-81-0564 Oracle returned error.

Reason: ORA-00376: file 9 cannot be read at this time

ORA-01111: name for data file 9 is unknown - rename to correct file

ORA-01110: data file 9: '/ora_base/db_home/dbs/MISSING00009'...

Workaround: There is no workaround for this issue.

If a CDB has a tablespace in the read-only mode, then the cloningfails (3512370)

For Oracle version 12.1.0.1, when a container database (CDB) has a tablespacein the read-only mode for all point-in-time copies, cloning of that CDB fails with thefollowing error message:

SFDB vxsfadm ERROR V-81-0564 Oracle returned error.

Reason: ORA-01122: database file 15 failed verification check

ORA-01110: data file 15: '/tmp/test1/data/sfaedb/newtbs1.dbf'

ORA-01202: wrong incarnation of this file - wrong creation time

...

Workaround: There is no workaround for this issue.

If any SFDB installation prior to 6.2 with authentication setup isupgraded to 7.0, the commands fail with an error (3644030)

The commands fail with the error message similar to the following:

SFDB vxsfadm ERROR V-81-0450 A remote or privileged command could not be

executed on prodhost

Reason: This can be caused by the host being unreachable or the vxdbd daemon

not running on that host or because of insufficient privileges.

Action: Verify that the prodhost is reachable. If it is, verify

that

115Known IssuesStorage Foundation for Databases (SFDB) tools known issues

Page 116: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

the vxdbd daemon is enabled and running using the [

/opt/VRTS/bin/sfae_config

status ] command, and enable/start vxdbd using the [

/opt/VRTS/bin/sfae_config

enable ] command if it is not enabled/running. Also make sure you are

authorized to run SFAE commands if running in secure mode.

Workaround:Set up the authentication for SFDB again. SeeStorage and AvailabilityManagement for Oracle Databases or Storage and Availability Management forDB2 Databases.

116Known IssuesStorage Foundation for Databases (SFDB) tools known issues

Page 117: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Software LimitationsThis chapter includes the following topics:

■ Storage Foundation software limitations

■ Replication software limitations

■ Cluster Server software limitations

■ Storage Foundation Cluster File System High Availability software limitations

■ Storage Foundation for Oracle RAC software limitations

■ Storage Foundation for Databases (SFDB) tools software limitations

Storage Foundation software limitationsThese software limitations apply to the following products:

■ Veritas InfoScale Foundation

■ Veritas InfoScale Storage

■ Veritas InfoScale Enterprise

Dynamic Multi-Pathing software limitationsThese software limitations apply to the following products:

■ Veritas InfoScale Foundation

■ Veritas InfoScale Storage

■ Veritas InfoScale Enterprise

10Chapter

Page 118: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

DMP does not support devices in the same enclosure thatare configured in different modes (2643506)DMP does not support the configuration where two devices in the same enclosureare configured in different modes. For example, if one device is configured as ALUAand another one is configured as Active/Passive (A/P).

DMP settings for NetApp storage attached environmentTo minimize the path restoration window and maximize high availability in theNetApp storage attached environment,change the default values for the DMPtunable parameters.

Table 10-1 describes the DMP tunable parameters and the new values.

Table 10-1 DMP settings for NetApp storage attached environment

Default valueNew valueDefinitionParameter name

300 seconds.60 seconds.DMP restore daemoncycle

dmp_restore_interval

300 seconds.120 seconds.DMP path agingtunable

dmp_path_age

The change is persistent across reboots.

To change the tunable parameters

1 Issue the following commands:

# vxdmpadm settune dmp_restore_interval=60

# vxdmpadm settune dmp_path_age=120

2 To verify the new settings, use the following commands:

# vxdmpadm gettune dmp_restore_interval

# vxdmpadm gettune dmp_path_age

DMP support in AIX virtualization environment (2138060)DMP does not support exporting paths to the same LUN through both vSCSI andNPIV interfaces.

118Software LimitationsStorage Foundation software limitations

Page 119: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

DMP treats the same LUN seen through vSCSI and NPIV interfaces as two separateLUNs, because the behavior of the LUN at the VIOC level is different due to theintermediate SCSI interface at the VIOS level for vSCSI devices.

LVM volume group in unusable state if last path isexcluded from DMP (1976620)When a DMP device is used by a native LVM volume group, do not exclude thelast path to the device. This can put the LVM volume group in an unusable state.

This issue is only applicable to non-root devices.

Veritas Volume Manager software limitationsThe following are software limitations in this release of Veritas Volume Manager.

MPIO device names shown in error state (3169587)In this release, DMP does not support extended attributes like AVID for AIX MPIOdevices. In the 5.1SP1 release, DMP used to support AVID for the MPIO devices.When you upgrade from 5.1SP1 or prior release to a release 6.0 or later, DMPassigns new names to the MPIO devices.

The MPIO device may go into an error state after the upgrade, if a persistent diskaccess record (entry in /etc/vx/darecs) exists with the old name, and the devicewas assigned a new name.

The same issue may occur if the MPIO device name changes for another reason,such as the changed cabinet serial numbers for 3PAR or XIV devices.

Workaround:

Use the following procedure to remove the persistent disk access record and resolvethe issue.

To resolve the issue with MPIO devices in error state

1 Remove the following file:

# rm /etc/vx/darecs

2 Reset the vxconfigd daemon:

# vxconfigd -kr reset

119Software LimitationsStorage Foundation software limitations

Page 120: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Snapshot configuration with volumes in shared diskgroups and private disk groups is not supported (2801037)A snapshot configuration with volumes in the shared disk groups and private diskgroups is not a recommended configuration. In this release, this configuration isnot supported.

Storage reclamation does not happen on volumes withbreak-off snapshot (2798523)In this release, storage reclamation on a volume is prevented when it has a break-offtype snapshot. If storage reclamation is allowed on such volumes, it can lead tothe following undesired situation. Instant snapshot operations, including vxsnap

refresh and vxsnap restore operations, lead to full synchronization of either thesnapshot or the primary volume depending on the operation.

In this release, if the volume has a snapshot, the storage reclamation is silentlyprevented. The physical storage is not reduced. The reclaim command reports thatthe reclamation is done on the disks but the actual storage is not reclaimed forvolumes with snapshots:

# vxdisk -o full reclaim dg1

Reclaiming storage on:

Disk xiv0_617 : Done.

Disk xiv0_616 : Done.

Disk xiv0_618 : Done.

Disk xiv0_612 : Done.

Disk xiv0_613 : Done.

Disk xiv0_614 : Done.

Disk xiv0_615 : Done

As shown in the following example output, the storage is not actually reclaimed.

# vxdisk -o thin list

DEVICE SIZE(MB) PHYS_ALLOC(MB) GROUP TYPE

xiv0_612 19313 2101 dg1 thinrclm

xiv0_613 19313 2108 dg1 thinrclm

xiv0_614 19313 35 dg1 thinrclm

xiv0_615 19313 32 dg1 thinrclm

xiv0_616 19313 31 dg1 thinrclm

xiv0_617 19313 31 dg1 thinrclm

xiv0_618 19313 31 dg1 thinrclm

120Software LimitationsStorage Foundation software limitations

Page 121: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

SmartSync is not supported for Oracle databases runningon raw VxVM volumesSmartSync is not supported for Oracle databases that are configured on rawvolumes, because Oracle does not support the raw volume interface.

Veritas Infoscale does not support thin reclamation ofspace on a linked mirror volume (2729563)The thin reclamation feature does not support thin reclamation for a linked mirrorvolume.

Thin reclamation requests are not redirected even whenthe ioship policy is enabled (2755982)Reclamation requests fail from nodes that do not have local connectivity to thedisks, even when the ioship policy is enabled. Reclamation I/Os are not redirectedto another node.

Veritas Operations Manager does not support disk, diskgroup, and volume state information related to CVM I/Oshipping feature (2781126)The Veritas Operations Manager (VOM) does not support disk, disk group, andvolume state information related to the I/O shipping feature introduced in this releaseof Cluster Volume Manager. New states such as lfailed, lmissing or LDISABLEDare introduced when I/O shipping is active because of storage disconnectvity.

Veritas File System software limitationsThe following are software limitations in this release of Veritas File System.

Recommended limit of number of files in a directoryTo maximize VxFS performance, do not exceed 100,000 files in the same directory.Use multiple directories instead.

The shell cannot handle 64-bit inode numbers inside the.checkpoint directory when uniqueino is enabledDue to a limitation with the AIX operating system, the shell cannot handle the 64-bitinode numbers inside the .checkpoint directory when the uniqueinomount optionis enabled. Some shell functions such as auto-complete and globs, for example rm*, do not function properly in the .checkpoint directory. This also affects 32-bit

121Software LimitationsStorage Foundation software limitations

Page 122: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

applications that try to read the contents of the .checkpoint directory or any of itssubdirectories. This does not affect any 64-bit applications.

The vxlist command cannot correctly display numbersgreater than or equal to 1 EBThe vxlist command and all of the other commands that use the same library asthe vxlist command cannot correctly display numbers greater than or equal to 1EB.

Limitations with delayed allocation for extending writesfeatureThe following limitations apply to the delayed allocation for extending writes feature:

■ In the cases where the file data must be written to disk immediately, delayedallocation is disabled on that file. Examples of such cases include Direct I/O,concurrent I/O, FDD/ODM access, and synchronous I/O.

■ Delayed allocation is not supported on memory mapped files.

■ Delayed allocation is not supported with BSD quotas. When BSD quotas areenabled on a file system, delayed allocation is turned off automatically for thatfile system.

■ Delayed allocation is not supported for shared mounts in a cluster file system.

FlashBackup feature of NetBackup 7.5 (or earlier) doesnot support disk layout Version 8, 9, or 10The FlashBackup feature of NetBackup 7.5 (or earlier) does not support disk layoutVersion 8, 9, or 10.

SmartIO software limitationsThe following are the SmartIO software limitations in this release.

The sfcache operations may display error messages inthe caching logwhen the operation completed successfully(3611158)The sfcache command calls other commands to perform the caching operations.If a command fails, additional commands may be called to complete the operation.For debugging purposes, the caching log includes all of the success messages andfailure messages for the commands that are called.

122Software LimitationsStorage Foundation software limitations

Page 123: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

If the sfcache command has completed successfully, you can safely ignore theerror messages in the log file.

Replication software limitationsThese software limitations apply to the following products:

■ Veritas InfoScale Storage

■ Veritas InfoScale Enterprise

VVR Replication in a shared environmentCurrently, replication support is limited to 8-node cluster applications.

VVR IPv6 software limitationsVVR does not support the following Internet Protocol configurations:

■ A replication configuration from an IPv4-only node to an IPv6-only node andfrom an IPv6-only node to an IPv4-only node is not supported, because theIPv6-only node has no IPv4 address configured on it and therefore VVR cannotestablish communication between the two nodes.

■ A replication configuration in which an IPv4 address is specified for thelocal_host attribute of a primary RLINK and an IPv6 address is specified forthe remote_host attribute of the same RLINK.

■ A replication configuration in which an IPv6 address is specified for thelocal_host attribute of a primary RLINK and an IPv4 address is specified forthe remote_host attribute of the same RLINK.

■ IPv6 is not supported in a CVM and VVR cluster where some nodes in the clusterare IPv4-only and other nodes in the same cluster are IPv6-only, or all nodesof a cluster are IPv4-only and all nodes of a remote cluster are IPv6-only.

■ VVR does not support Edge and NAT-PT routers that facilitate IPv4 and IPv6address translation.

VVR support for replicating across Storage Foundation versionsVVR supports replication between Storage Foundation 6.1 and the prior majorreleases of Storage Foundation (6.0 and 6.0.1). Replication between versions issupported for disk group versions 170, 180, and 190 only. Both the Primary andSecondary hosts must be using a supported disk group version.

123Software LimitationsReplication software limitations

Page 124: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Cluster Server software limitationsThese software limitations apply to the following products:

■ Veritas InfoScale Availability

■ Veritas InfoScale Enterprise

Limitations related to bundled agents

Programs using networked servicesmay stop respondingif the host is disconnectedPrograms using networked services (for example, NIS, NFS, RPC, or a TCP socketconnection to a remote host) can stop responding if the host is disconnected fromthe network. If such a program is used as an agent entry point, a network disconnectcan cause the entry point to stop responding and possibly time out.

For example, if the host is configured to use NIS maps as a client, basic commandssuch as ps -ef can hang if there is network disconnect.

Symantec recommends creating users locally. To reflect local users, configure:

/etc/netsvc.conf

Volume agent clean may forcibly stop volume resourcesWhen the attribute FaultOnMonitorTimeouts calls the Volume agent clean entrypoint after a monitor time-out, the vxvol -f stop command is also issued. Thiscommand forcibly stops all volumes, even if they are still mounted.

False concurrency violationwhen usingPidFiles tomonitorapplication resourcesThe PID files created by an application contain the PIDs for the processes that aremonitored by Application agent. These files may continue to exist even after a noderunning the application crashes. On restarting the node, the operating system mayassign the PIDs listed in the PID files to other processes running on the node.

Thus, if the Application agent monitors the resource using the PidFiles attributeonly, the agent may discover the processes running and report a false concurrencyviolation. This could result in some processes being stopped that are not underVCS control.

124Software LimitationsCluster Server software limitations

Page 125: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Volumes in a disk group start automatically irrespectiveof the value of the StartVolumes attribute in VCS [2162929]Volumes in a disk group are started automatically when the disk group is imported,irrespective of the value of the StartVolumes attribute in VCS. This behavior isobserved if the value of the system-level attribute autostartvolumes in VeritasVolume Manager is set to On.

Workaround: If you do not want the volumes in a disk group to start automaticallyafter the import of a disk group, set the autostartvolumes attribute to Off at thesystem level.

WPAR agent registered to IMF for Directory Online eventThe Directory Online event monitors theWPAR root directory. If the parent directoryof the WPAR root directory is deleted or moved to another location, AMF does notprovide notification to the WPAR agent. In the next cycle of the WPAR monitor, itdetects the change and reports the state of the resource as offline.

Application agent limitations■ ProPCV fails to prevent execution of script-based processes configured under

MonitorProcesses.

Campus cluster fire drill does not work when DSM sitesare used to mark site boundaries [3073907]The campus cluster FireDrill agent currently uses the SystemZones attribute toidentify site boundaries. Hence, campus cluster FireDrill is not supported in DSMenabled environment.

Workaround: Disable DSM and configure the SystemZones attribute on theapplication service group to perform the fire drill.

Live Partition Mobility (LPM) of management LPAR is notsupportedLive Partition Mobility (LPM) of management LPAR is not supported.

Mount agent reports resource state as OFFLINE if theconfigured mount point does not exist [3435266]If a configured mount point does not exist on a node, then the Mount agent reportsthe resource state as OFFLINE instead of UNKNOWN on that particular node. Ifan attempt is made for onlining the resource, it fails on that node as the mount pointdoes not exist.

125Software LimitationsCluster Server software limitations

Page 126: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Workaround: Make sure that configured mount point exists on all nodes of thecluster or alternatively set the CreateMntPt attribute value of Mount agent to 1. Thiswill ensure that if a mount point does not exist then it will create while onlining theresource.

Limitations related to VCS engine

Loads fail to consolidate and optimize when multiplegroups fault [3074299]When multiple groups fault and fail over at the same time, the loads are notconsolidated and optimized to choose the target systems.

Workaround: No workaround.

Preferred fencing ignores the forecasted available capacity[3077242]Preferred fencing in VCS does not consider the forecasted available capacity forfencing decision. The fencing decision is based on the system weight configured.

Workaround: No workaround.

Failover occurs within the SystemZone or site whenBiggestAvailable policy is set [3083757]Failover always occurs within the SytemZone or site when the BiggestAvailablefailover policy is configured. The target system for failover is always selected basedon the biggest available system within the SystemZone.

Workaround: No workaround.

Load for Priority groups is ignored in groups withBiggestAvailable and Priority in the same group[3074314]When there are groups with both BiggestAvailable and Priority as the failover policyin the same cluster, the load for Priority groups are not considered.

Workaround: No workaround.

126Software LimitationsCluster Server software limitations

Page 127: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Cluster configuration wizard limitations

Environment variable used to change log directory cannotredefine the log path of the wizard [3609791]By default, the cluster configuration wizard writes the logs in /var/VRTSvcs/log

directory. VCS provides a way to change the log directory through environmentvariable VCS_LOG, but this does not apply to the logs of VCS wizards.

Workaround: No workaround.

Limitations related to IMF■ If a process is registered with IMF for offline monitoring, IMF may not detect the

process being executed if the length of the process and related argumentsexceed 70 characters. In case of ProPCV, IMF may not be able to prevent theprocess from coming online if the length of the process and related argumentsexceeds 70 characters. This limitation affects Application agent and Processagent. Refer to the Cluster Server Bundled Agents Reference Guide for moreinformation. [2768558]

Limitations related to the VCS database agents

DB2 RestartLimit value [1234959]When multiple DB2 resources all start at the same time with no dependencies, theytend to interfere or race with each other. This is a known DB2 issue.

The default value for the DB2 agent RestartLimit is 3. This higher value spreadsout the re-start of the DB2 resources (after a resource online failure), which lowersthe chances of DB2 resources all starting simultaneously.

Pluggable database (PDB) onlinemay timeoutwhen startedafter container database (CDB) [3549506]PDB may take long time to start when it is started for the first time after startingCDB. As a result, the PDB online initiated using VCS may cause ONLINE timeoutand the PDB online process may get cancelled.

Workaround: Increase the OnlineTimeout attribute value of the Oracle type resource.

127Software LimitationsCluster Server software limitations

Page 128: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Systems in a cluster must have same system locale settingVCS does not support clustering of systems with different system locales. All systemsin a cluster must be set to the same locale.

Limitations with DiskGroupSnap agent [1919329]The DiskGroupSnap agent has the following limitations:

■ The DiskGroupSnap agent does not support layered volumes.

■ If you use the Bronze configuration for the DiskGroupSnap resource, you couldend up with inconsistent data at the secondary site in the following cases:

■ After the fire drill service group is brought online, a disaster occurs at theprimary site during the fire drill.

■ After the fire drill service group is taken offline, a disaster occurs at theprimary while the disks at the secondary are resynchronizing.

Symantec recommends that you use the Gold configuration for theDiskGroupSnap resource.

Virtualizing shared storage using VIO servers and client partitionsIn an Advanced POWER™ Virtualization (APV) environment, AIX uses the VIOServer to monitor and manage the I/O paths for the virtualized client partitions. Ata very high level, the VIO server provides a partition’s access to storage that isexternal to the physical computer. The VIO server encapsulates the physicalhardware into virtual adapters called virtual SCSI adapters (server adapter). Onthe client side, you can create virtual adapters (client adapters) that map to theserver adapter and enable a partition to connect to external storage.

The VIO server provides similar mechanisms to share limited networking resourcesacross partitions. Refer to the manual that came with your system to help set uppartitions, and to configure and use the various components such as VIO serverand HMC, which are integral parts of IBM's APV environment.

Theminimum patch level for using VIO servers with VCS is: version 2.1.3.10-FP-23and later.

Supported storageRefer to the IBM data sheet:

http://www14.software.ibm.com/webapp/set2/sas/f/vios/home.html

128Software LimitationsCluster Server software limitations

Page 129: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Disk RestrictionsWhen using VCS in combination with VIO servers and their client partitions, youneed to ensure that no reservations are placed on the shared storage. This enablesclient partitions on different systems to access and use the same shared storage.

■ If the shared storage is under MPIO control, set the reserve_policy attribute ofthe disk to no_reserve.

■ If the shared storage is not under MPIO control, look up the array documentationto locate a similar attribute to set on the disk.

Internal testing on EMC disks shows that this field maps as the reserve_lock attributefor EMC disks. In this case, setting it to no achieves the same result.

Accessing the same LUNs from Client Partitions ondifferent Central Electronics Complex (CEC) modulesThis section briefly outlines how to set shared storage so that it is visible from clientpartitions on different CEC modules.

With the VIO server and client partitions set up and ready, make sure that you haveinstalled the right level of operating system on the client partitions, and that youhave mapped the physical adapters to the client partitions to provide access to theexternal shared storage.

To create a shareable diskgroup, you need to ensure that the different partitionsuse the same set of disks. A good way to make sure that the disks (that are seenfrom multiple partitions) are the same is to use the disks serial numbers, which areunique.

Run the following commands on the VIO server (in non-root mode), unless otherwisenoted.

Get the serial number of the disk of interest:

$ lsdev -dev hdisk20 -vpd

hdisk20

U787A.001.DNZ06TT-P1-C6-T1-W500507630308037C-

L401 0401A00000000 IBM FC 2107

Manufacturer................IBM

Machine Type and Model......2107900

Serial Number...............7548111101A

EC Level.....................131

Device Specific.(Z0)........10

Device Specific.(Z1)........0100

129Software LimitationsCluster Server software limitations

Page 130: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Make sure the other VIO server returns the same serial number. This ensures thatyou are viewing the same actual physical disk.

List the virtual SCSI adapters.

$ lsdev -virtual | grep vhost

vhost0 Available Virtual SCSI Server Adapter

vhost1 Available Virtual SCSI Server Adapter

Note: Usually vhost0 is the adapter for the internal disks. vhost1 in the exampleabove maps the SCSI adapter to the external shared storage.

Prior to mapping hdisk20 (in the example) to a SCSI adapter, change the reservationpolicy on the disk.

$ chdev -dev hdisk20 -attr reserve_policy=no_reserve

hdisk20 changed

For hdisk20 (in the example) to be available to client partitions, map it to a suitablevirtual SCSI adapter.

If you now print the reserve policy on hdisk20 the output resembles:

$ lsdev -dev hdisk20 attr reserve_policy

value

no_reserve

Next create a virtual device to map hdisk20 to vhost1.

$ mkvdev -vdev hdisk20 -vadapter vhost1 -dev mp1_hdisk5

mp1_hdisk5 Available

Finally on the client partition run the cfgmgr command to make this disk visible viathe client SCSI adapter.

You can use this disk (hdisk20 physical, and known as mp1_hdisk5 on the clientpartitions) to create a diskgroup, a shared volume, and eventually a shared filesystem.

Perform regular VCS operations on the clients vis-a-vis service groups, resources,resource attributes, etc.

Cluster Manager (Java console) limitationsThis section covers the software limitations for Cluster Manager (Java Console).

130Software LimitationsCluster Server software limitations

Page 131: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Cluster Manager does not work if the hosts file containsIPv6 entriesVCSCluster Manager fails to connect to the VCS engine if the /etc/hosts file containsIPv6 entries.

Workaround: Remove IPv6 entries from the /etc/hosts file.

VCS Simulator does not support I/O fencingWhen running the Simulator, be sure the UseFence attribute is set to the default,“None”.

The operating system does not distinguish between IPv4 and IPv6packet counts

In a dual-stack configuration, when you use packet counts and the IPv6 network isdisabled, the NIC agent might not detect a faulted NIC. It might not detect a faultbecause while the IPv6 network is down its packet count still increases. The packetcount increases because the operating system does not distinguish between thepacket counts for IPv4 and IPv6 networks. The agent then concludes that the NICis up. If you are using the same NIC device for IPv4 as well as IPv6 resources, setPingOptimize to 0 and specify a value for the NetworkHosts attribute for either theIPv6 or the IPv4 NIC resource. [1061253]

A service group that runs inside of a WPAR may not fail over whenits network connection is lost

For a WPAR configuration when the WPAR root is on NFS, the WPAR servicegroup may not fail over if the NFS connection is lost. This issue is due to an AIXoperating system limitation. [1637430]

Limitations related to I/O fencingThis section covers I/O fencing-related software limitations.

Preferred fencing limitationwhen VxFEN activates RACERnode re-electionThe preferred fencing feature gives preference to more weighted or largersubclusters by delaying the smaller subcluster. This smaller subcluster delay iseffective only if the initial RACER node in the larger subcluster is able to completethe race. If due to some reason the initial RACER node is not able to complete therace and the VxFEN driver activates the racer re-election algorithm, then the smaller

131Software LimitationsCluster Server software limitations

Page 132: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

subcluster delay is offset by the time taken for the racer re-election and the lessweighted or smaller subcluster could win the race. This limitation though notdesirable can be tolerated.

Limitation with RDAC driver and FAStT array forcoordinator disks that use raw disksFor multi-pathing to connected storage, AIX uses the RDAC driver for FAStT arrays.Since it is an active/passive array, only the current active path is exposed to clients.The I/O fencing driver, vxfen, can use only a single active path and has noforeknowledge of the passive paths to the coordinator disks on an array. If the singleactive path fails, all nodes in the cluster lose access to the coordinator disks.

The loss of the path to the coordinator disks can potentially go unnoticed until areboot, split brain, or any other reason that leads to a cluster membership changeoccurs. In any of these conditions, the cluster cannot form, and all nodes panic toprevent data corruption. No data loss occurs.

Workaround: Use DMP and specify paths to coordinator disks as DMP paths ratherthan raw disks to avoid this limitation.

Stopping systems in clusters with I/O fencing configuredThe I/O fencing feature protects against data corruption resulting from a failedcluster interconnect, or “split brain.” See the Cluster Server Administrator's Guidefor a description of the problems a failed interconnect can create and the protectionI/O fencing provides.

In a cluster using SCSI-3 based fencing, I/O fencing implements data protectionby placing the SCSI-3 PR keys on both the data disks and coordinator disks. In acluster using CP server-based fencing, I/O fencing implements data protection byplacing the SCSI-3 PR keys on data disks and similar registrations on CP server.The VCS administrator must be aware of several operational changes needed whenworking with clusters protected by I/O fencing. Specific shutdown procedures ensurekeys are removed from coordination points and data disks to prevent possibledifficulties with subsequent cluster startup.

Using the reboot command rather than the shutdown command bypasses shutdownscripts and can leave keys on the coordination points and data disks. Dependingon the order of reboot and subsequent startup events, the cluster may warn of apossible split brain condition and fail to start up.

Workaround: Use the shutdown -r command on one node at a time and wait foreach node to complete shutdown.

132Software LimitationsCluster Server software limitations

Page 133: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Uninstalling VRTSvxvm causes issues when VxFEN isconfigured in SCSI3 mode with dmp disk policy (2522069)When VxFEN is configured in SCSI3 mode with dmp disk policy, the DMP nodesfor the coordinator disks can be accessed during system shutdown or fencingarbitration. After uninstalling VRTSvxvm fileset, the DMP module will no longer beloaded in memory. On a system where VRTSvxvm fileset is uninstalled, if VxFENattempts to access DMP devices during shutdown or fencing arbitration, the systempanics.

Node may panic if HAD process is stopped by force andthen node is shut down or restarted [3640007]A node may panic if the HAD process running on it is stopped by force and then itis shut down or restarted.This limitation is observed when you perform the followingsteps on a cluster node:

1 Stop the HAD process with the force flag.

# hastop -local -force

or

# hastop -all -force

2 Restart or shut down the node.

The node panics because forcefully stopping VCS on the node leaves all theapplications, file systems, CVM, and other process online on that node. If the samenode is restarted in this starte, VCS triggers a fencing race to avoid data curruption.However, the restarted node loses the fencing race and panics.

Workaround: No workaround.

Limitations related to global clusters■ Cluster address for global cluster requires resolved virtual IP.

The virtual IP address must have a DNS entry if virtual IP is used for heartbeatagents.

■ Total number of clusters in a global cluster configuration can not exceed four.

■ Cluster may not be declared as faulted when Symmheartbeat agent is configuredeven when all hosts are down.The Symm agent is used to monitor the link between two Symmetrix arrays.When all the hosts are down in a cluster but the Symm agent is able to see thereplication link between the local and remote storage, it would report the

133Software LimitationsCluster Server software limitations

Page 134: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

heartbeat as ALIVE. Due to this, DR site does not declare the primary site asfaulted.

Clusters must run on VCS 6.0.5 and later to be able to communicateafter upgrading to 2048 bit key and SHA256 signature certificates[3812313]

In global clusters, when you install or upgrade VCS to 7.0 and you upgrade to 2048bit key and SHA256 signature certificates on one site and the other site is on VCSversion lower than 6.0.5, the clusters fail to communicate. The cluster communicationwill not be restored even if you restore the trust between the clusters. This includesGCO, Steward and CP server communication.

Workaround:

You must upgrade VCS to version 6.0.5 or later to enable the global clusters tocommunicate.

Storage Foundation Cluster File System HighAvailability software limitations

These software limitations apply to the following products:

■ Veritas InfoScale Storage

■ Veritas InfoScale Enterprise

cfsmntadm command does not verify the mount options (2078634)You must confirm the mount options are correct which are then passed to thecfsmntadm command. If the mount options are not correct, the mount fails and theCFSMount resource will not come online. You can check the VCS engine log filefor any mount failure messages.

Upgrade of secure clusters not supported using native operatingsystem tools

This release does not support the upgrade of secure clusters using native operatingsystem tools such as Alternate Disk Installation (ADI) and Network Install ManagerAlternate Disk Migration (NIMADM).

134Software LimitationsStorage Foundation Cluster File System High Availability software limitations

Page 135: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Stale SCSI-3 PR keys remain on disk after stopping the cluster anddeporting the disk group

When all nodes present in the Veritas Infoscale cluster are removed from the cluster,the SCSI-3 Persistent Reservation (PR) keys on the data disks may not getpreempted. As a result, the keys may be seen on the disks after stopping the clusteror after the nodes have booted up. The residual keys do not impact data disk fencingas they will be reused or replaced when the nodes rejoin the cluster. Alternatively,the keys can be cleared manually by running the vxfenclearpre utility.

For more information on the vxfenclearpre utility, see the Veritas InfoscaleAdministrator's Guide.

Unsupported FSS scenariosThe following scenario is not supported with Flexible Storage Sharing (FSS):

Veritas NetBackup backup with FSS disk groups

Storage Foundation for Oracle RAC softwarelimitations

These software limitations apply to Veritas InfoScale Enterprise.

Supportability constraints for normal or high redundancy ASM diskgroups with CVM I/O shipping and FSS (3600155)

Normal or high redundancy ASM disk groups are not supported in FSS environmentsor if CVM I/O shipping is enabled.

Configure ASM disk groups with external redundancy in these scenarios.

Limitations of CSSD agentThe limitations of the CSSD agent are as follows:

■ For Oracle RAC 11g Release 2 and later versions: The CSSD agent restartsOracle Grid Infrastructure processes that you may manually or selectively takeoffline outside of VCS.Workaround: First stop the CSSD agent if operations require you to manuallytake the processes offline outside of VCS.For more information, see the topic "Disabling monitoring of Oracle GridInfrastructure processes temporarily" in the Storage Foundation for Oracle RACConfiguration and Upgrade Guide.

135Software LimitationsStorage Foundation for Oracle RAC software limitations

Page 136: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

■ The CSSD agent detects intentional offline only when you stop OracleClusterware/Grid Infrastructure outside of VCS using the following command:crsctl stop crs [-f]. The agent fails to detect intentional offline if you stopOracle Clusterware/Grid Infrastructure using any other command.Workaround: Use the crsctl stop crs [-f] command to stop OracleClusterware/Grid Infrastructure outside of VCS.

Oracle Clusterware/Grid Infrastructure installation fails if the clustername exceeds 14 characters

Setting the cluster name to a value that exceeds 14 characters during the installationof Oracle Clusterware/Grid Infrastructure causes unexpected cluster membershipissues. As a result, the installation may fail.

Workaround: Restart the Oracle Clusterware/Grid Infrastructure installation andset the cluster name to a value of maximum 14 characters.

Policy-managed databases not supported by CRSResource agentThe CRSResource agent supports only admin-managed database environmentsin this release. Policy-managed databases are not supported.

Health checks may fail on clusters that have more than 10 nodesIf there are more than 10 nodes in a cluster, the health check may fail with thefollowing error:

vxgettext ERROR V-33-1000-10038

Arguments exceed the maximum limit of 10

The health check script uses the vxgettext command, which does not supportmore than 10 arguments.[2142234]

Cached ODM not supported in Veritas Infoscale environmentsCached ODM is not supported for files on Veritas local file systems and on ClusterFile System.

Storage Foundation for Databases (SFDB) toolssoftware limitations

The following are the SFDB tools software limitations in this release.

136Software LimitationsStorage Foundation for Databases (SFDB) tools software limitations

Page 137: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Parallel execution of vxsfadm is not supported (2515442)Only one instance of the vxsfadm command can be run at a time. Running multipleinstances of vxsfadm at a time is not supported.

Creating point-in-time copies during database structural changes isnot supported (2496178)

SFDB tools do not support creating point-in-time copies while structural changesto the database are in progress, such as adding or dropping tablespaces and addingor dropping data files.

However, once a point-in-time copy is taken, you can create a clone at any time,regardless of the status of the database.

Oracle Data Guard in an Oracle RAC environmentSFDB tools cannot be used with RAC standby databases. SFDB tools can still beused with the primary database, even in a Data Guard Oracle RAC environment.

137Software LimitationsStorage Foundation for Databases (SFDB) tools software limitations

Page 138: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

DocumentationThis chapter includes the following topics:

■ Veritas InfoScale documentation

■ Documentation set

Veritas InfoScale documentationVeritas InfoScale documentation is available in the Adobe Portable DocumentFormat (PDF) on the product media or with the downloaded software.

See the release notes for information on documentation changes in this release.

The documentation is available in the /docs directory on the product media.

Make sure that you are using the current version of documentation. The documentversion appears on page 2 of each guide. The publication date appears on the titlepage of each document. The documents are updated periodically for errors orcorrections. The latest documentation is available on the Veritas Services andOperations Readiness Tools (SORT) website.

https://sort.veritas.com/documents

You need to specify the product and the platform and apply other filters for findingthe appropriate document.

Documentation setThe Veritas InfoScale documentation includes a common installation guide andrelease notes that apply to all products. Each component in the Veritas Infoscaleproduct includes a configuration guide and additional documents such asadministration and agent guides.

11Chapter

Page 139: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Veritas InfoScale product documentationTable 11-1 lists the documentation for Veritas InfoScale products.

Table 11-1 Veritas InfoScale product documentation

DescriptionFile nameDocument title

Provides information on how to install theVeritas InfoScale products.

infoscale_install_70_aix.pdfVeritas InfoScale Installation Guide

Provides release information such assystem requirements, changes, fixedincidents, known issues, and limitations ofVeritas InfoScale.

infoscale_notes_70_aix.pdfVeritas InfoScale Release Notes

Provides information about the new featuresand enhancements in the release.

infoscale_whatsnew_70_unix.pdfVeritas InfoScale—What's new inthis release

(This document is available online.)

Provides a high-level overview of installingVeritas Infoscale products using thescript-based installer. The guide is usefulfor new users and returning users that wanta quick refresher.

infoscale_getting_started_70_aix.pdfVeritas InfoScale Getting StartedGuide

Provides information about how VeritasInfoscale components and features can beused individually and in concert to improveperformance, resilience and ease ofmanagement for storage and applications.

infoscale_solutions_70_aix.pdfVeritas InfoScale Solutions Guide

Provides information about VeritasInfoScale support for virtualizationtechnologies. Review this entire documentbefore you install virtualization software onsystems running Veritas Infoscale products.

infoscale_virtualization_70_aix.pdfVeritas InfoScale VirtualizationGuide

(This document is available online.)

Provides information on using andadministering SmartIO with VeritasInfoScale. Also includes troubleshootingand command reference sheet for SmartIO.

infoscale_smartio_solutions_70_aix.pdfVeritas InfoScale SmartIO for SolidState Drives Solutions Guide

Provides information on configuring campusclusters, global clusters, and replicated dataclusters (RDC) for disaster recovery failoverusing Veritas Infoscale products.

infoscale_dr_impl_70_aix.pdfVeritas InfoScale Disaster RecoveryImplementation Guide

(This document is available online.)

139DocumentationDocumentation set

Page 140: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Table 11-1 Veritas InfoScale product documentation (continued)

DescriptionFile nameDocument title

Provides information on using VolumeReplicator (VVR) for setting up an effectivedisaster recovery plan by maintaining aconsistent copy of application data at oneor more remote locations.

infoscale_replication_admin_70_aix.pdfVeritas InfoScale ReplicationAdministrator's Guide

Provides information on common issuesthat might be encountered when usingVeritas InfoScale and possible solutions forthose issues.

infoscale_tshoot_70_aix.pdfVeritas InfoScale TroubleshootingGuide

Provides information required foradministering DMP.

dmp_admin_70_aix.pdfDynamic Multi-PathingAdministrator's Guide

Storage Foundation for Oracle RAC documentationTable 11-2 lists the documentation for Storage Foundation for Oracle RAC.

Table 11-2 Storage Foundation for Oracle RAC documentation

DescriptionFile nameDocument title

Provides information required toconfigure and upgrade the component.

sfrac_config_70_aix.pdfStorage Foundation for Oracle RACConfiguration and Upgrade Guide

Provides information required foradministering and troubleshooting thecomponent.

sfrac_admin_70_aix.pdfStorage Foundation for Oracle RACAdministrator's Guide

The Veritas InfoScale documents describe functionality and solutions relevant tothe SF Oracle RAC product.

See Table 11-1 on page 139.

Storage Foundation Cluster File System High AvailabilitydocumentationTable 11-3 lists the documentation for Storage Foundation Cluster File SystemHigh Availability.

The Veritas InfoScale documents describe functionality and solutions relevant tothe SFCFSHA product.

See Table 11-1 on page 139.

140DocumentationDocumentation set

Page 141: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Table 11-3 Storage Foundation Cluster File System High Availabilitydocumentation

DescriptionFile nameDocument title

Provides information required toconfigure and upgrade the component.

sfcfs_config_70_aix.pdfStorage Foundation Cluster FileSystem High Availability Configurationand Upgrade Guide

Provides information required foradministering the component.

sfcfs_admin_70_aix.pdfStorage Foundation Cluster FileSystem High AvailabilityAdministrator's Guide

Storage Foundation and High AvailabilityTable 11-4 lists the documentation for Storage Foundation and High Availability.

For cluster administration, refer to the Cluster Server Administrator's Guide.

See the section called “ Cluster Server documentation” on page 141.

For storage administration, refer to the Storage Foundation Administrator's Guide.

See the section called “ Storage Foundation documentation” on page 142.

The Veritas InfoScale documents describe functionality and solutions relevant tothe SFHA product.

See Table 11-1 on page 139.

Table 11-4 Storage Foundation and High Availability documentation

DescriptionFile nameDocument title

Provides information required toConfigure and upgrade thecomponent.

sfha_config_70_aix.pdfStorage Foundation and HighAvailability Configuration and UpgradeGuide

Cluster Server documentationTable 11-5 lists the documents for Cluster Server.

Table 11-5 Cluster Server documentation

DescriptionFile nameTitle

Provides information required to configureand upgrade the component.

vcs_config_70_aix.pdfCluster Server Configuration andUpgrade Guide

Provides information required foradministering the component.

vcs_admin_70_aix.pdfCluster Server Administrator’s Guide

141DocumentationDocumentation set

Page 142: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Table 11-5 Cluster Server documentation (continued)

DescriptionFile nameTitle

Provides information about bundledagents, their resources and attributes, andmore related information.

vcs_bundled_agents_70_aix.pdfCluster Server Bundled AgentsReference Guide

Provides information about the variousVeritas Infoscale agents and proceduresfor developing custom agents.

vcs_agent_dev_70_unix.pdfCluster Server Agent Developer’sGuide

(This document is available onlineonly.)

Provides notes for installing andconfiguring the DB2 agent.

vcs_db2_agent_70_aix.pdfCluster Server Agent for DB2Installation and Configuration Guide

Provides notes for installing andconfiguring the Oracle agent.

vcs_oracle_agent_70_aix.pdfCluster Server Agent for OracleInstallation and Configuration Guide

Provides notes for installing andconfiguring the Sybase agent.

vcs_sybase_agent_70_aix.pdfCluster Server Agent for SybaseInstallation and Configuration Guide

Storage Foundation documentationTable 11-6 lists the documentation for Storage Foundation.

Table 11-6 Storage Foundation documentation

DescriptionFile nameDocument title

Provides information required to configureand upgrade the component.

sf_config_70_aix.pdfStorage Foundation Configurationand Upgrade Guide

Provides information required foradministering the component.

sf_admin_70_aix.pdfStorage Foundation Administrator'sGuide

Provides information about the deploymentand key use cases of the SFDB tools withVeritas InfoScale products in DB2 databaseenvironments. It is a supplemental guide tobe used in conjunction with other VeritasInfoScale guides.

infoscale_db2_admin_70_unix.pdfVeritas InfoScale Storage andAvailability Management for DB2Databases

Provides information about the deploymentand key use cases of the SFDB tools withVeritas InfoScale products in Oracledatabase environments. It is a supplementalguide to be used in conjunction with otherVeritas InfoScale guides.

infoscale_oracle_admin_70_unix.pdfVeritas InfoScale Storage andAvailability Management for OracleDatabases

142DocumentationDocumentation set

Page 143: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Table 11-6 Storage Foundation documentation (continued)

DescriptionFile nameDocument title

Provides developers with the informationnecessary to use the applicationprogramming interfaces (APIs) to modify andtune various features and components of theVeritas File System.

vxfs_ref_70_aix.pdfVeritas File System Programmer'sReference Guide (This documentis available online only.)

Veritas InfoScale Operations Manager is a management tool that you can use tomanage Veritas InfoScale products. If you use Veritas InfoScale OperationsManager, refer to the Veritas InfoScale Operations Manager product documentationat:

https://sort.veritas.com/documents

143DocumentationDocumentation set

Page 144: Veritas InfoScale 7.0 Release Notes - AIX · Ifyouhaveashared(system)WPARconfigured,whenyouinstall, upgrade,oruninstallanySymantecproduct,thefilesetsin theWPARarenotsynchronizedcorrespondingly

Aabout

SORT 23Veritas InfoScale 13Veritas InfoScale Availability 15Veritas InfoScale Enterprise 15Veritas InfoScale Foundation 14Veritas InfoScale product licensing 17Veritas InfoScale Storage 15VRTSvlic package 22vxlicinstupgrade utility 21

Ccomponents

Veritas InfoScale 15

IISO image

mounting 29

Kkeyless licensing

Veritas InfoScale 19Known issues

SFCFS 98

Llicensing

registering Veritas InfoScale product licensekeys 18

NNo longer supported 30

Rrelease information 12

Uupdating licenses

Veritas InfoScale 20

VVeritas InfoScale

about 13components 15keyless licensing 19mounting ISO image 29registering Veritas InfoScale product licensekeys 18

updating licenses 20Veritas InfoScale Availability

about 15Veritas InfoScale Enterprise

about 15Veritas InfoScale Foundation

about 14Veritas InfoScale Storage

about 15VxFS Limitations

software 121

Index


Recommended