Flow Double Case PD Flow Meters VERMONT Double Case Positive Displacement Flow Meters are specially designed to eliminate effect of line pressure on the metering chamber. Available in a wide range of flow capacities, the double case design ensures a high accuracy alongwith ease of servicing ‘in-situ’. DESIGN FEATURES Safe and rugged construction Double case design prevents distortion of measuring chamber due to line pressure fluctuations and ensures high accuracy Easy access to measuring chamber without need of removing the outer casing ensures minimum downtime Unique wear compensating vane design for sustained accuracy over a wide flow range Separate meter manifold prevents pipeline stresses from being transmitted to the measuring chamber Modular construction ensures interchangeable parts lower inventory of spares and ease of service Low pressure drop Mechanical or electronic readout fluctuations to ensure a high metering accuracy. The separate manifold design further enhances the performance and accuracy by preventing distortion due to pipe line stresses. PRINCIPLE OF OPERATION The liquid on entering the measuring chamber causes the rotor to revolve by exerting pressure on the vane blades. The proximity of the rotor to the body forms an efficient seal, while the profile of the body ensures that the vane blades are guided through the measuring crescent. The vane blades divide the liquid into segments and each revolution of the rotor displaces four such segments. The Double Case PD Flow Meter consists of an outer casing with measuring capsule fixed inside. The measuring capsule consists of a bulk meter body, rotor with vane blades and two internal covers. Outer end cover and manifold, bolted to the outer casing, form a closed chamber around the measuring capsule to keep it under equilibrium pressure all the time. The rotor spindle transmits the drive through a pressure tight lip seal in the meter front cover to the pulse transmitter or the calibrating mechanism, which calibrates the meter output for a corrected counter readout. All mechanical Double Case PD Flow Meters are fitted with Veeder Root mechanical counters. The product enters the Flow Meter measuring capsule through the manifold inlet and at the same time fills up the space between the outer casing and the measuring capsule. This effectively pressure balances the measuring capsule and prevents distortion due to line pressure Manifold o o o o Mechanical Counter Body Rotor Vane Blade cirpD Calibrating Mechanism Measuring Chamber Outer End Cover Outer Casing Measuring Crescent Copyright ' Vermont - www.vermonttechnologies.co.in
Transcript
Page 1: Vermont Flow Catalogue Double Case Meter1€¦ · • Solenoid Shut-off Valve Electrical Preset Switch • Temperature Sensor • Card Reader • Grounding Unit Body Material W =

Flow

Double Case PD Flow Meters VERMONT

Double Case Positive Displacement Flow Meters arespecially designed to eliminate effect of line pressure onthe metering chamber. Available in a wide range of flowcapacities, the double case design ensures a highaccuracy alongwith ease of servicing ‘in-situ’.

DESIGN FEATURES

• Safe and rugged construction• Double case design prevents distortion of measuring

chamber due to line pressure fluctuations andensures high accuracy

• Easy access to measuring chamber without need ofremoving the outer casing ensures minimumdowntime

• Unique wear compensating vane design for sustainedaccuracy over a wide flow range

• Separate meter manifold prevents pipeline stressesfrom being transmitted to the measuring chamber

• Modular construction ensures interchangeable partslower inventory of spares and ease of service

• Low pressure drop• Mechanical or electronic readout

fluctuations to ensure a high metering accuracy. Theseparate manifold design further enhances theperformance and accuracy by preventing distortion due topipe line stresses.

PRINCIPLE OF OPERATION The liquid on entering the measuring chamber causesthe rotor to revolve by exerting pressure on the vaneblades. The proximity of the rotor to the body forms anefficient seal, while the profile of the body ensures thatthe vane blades are guided through the measuringcrescent. The vane blades divide the liquid into segmentsand each revolution of the rotor displaces four suchsegments.

The Double Case PD Flow Meter consists of an outercasing with measuring capsule fixed inside. Themeasuring capsule consists of a bulk meter body, rotor

with vane blades and two internal covers. Outer end coverand manifold, bolted to the outer casing, form a closedchamber around the measuring capsule to keep it underequilibrium pressure all the time.

The rotor spindle transmits the drive through a pressuretight lip seal in the meter front cover to the pulse transmitteror the calibrating mechanism, which calibrates the meteroutput for a corrected counter readout. All mechanicalDouble Case PD Flow Meters are fitted with Veeder Rootmechanical counters.

The product enters the Flow Meter measuring capsulethrough the manifold inlet and at the same time fills upthe space between the outer casing and the measuringcapsule. This effectively pressure balances the measuringcapsule and prevents distortion due to line pressure

Manifold

o o

o oMechanical

CounterBody

Rotor

Vane Blade

cirpD

Calibrating Mechanism

Measuring Chamber

Outer End Cover

Outer Casing

MeasuringCrescent

Copyright ' Vermont - www.vermonttechnologies.co.in

Page 2: Vermont Flow Catalogue Double Case Meter1€¦ · • Solenoid Shut-off Valve Electrical Preset Switch • Temperature Sensor • Card Reader • Grounding Unit Body Material W =

Repeatability : Better than ±0.02%APPLICATIONS

: 100% to 10% of maximum flowrate

Rangeability• Tank truck and rail wagon gantry filling

• Refineries and high pressure metering inpetrochemical, process and chemical industries Maximum Working

Pressure: 150 PSI

300 PSI (Optional)

• Blending and batching in lube plants, process controland chemical industries : Upto 70°C (Standard)

Upto 200°C (Special)Temperature

• Microprocessor based automation, remote control anddata acquisition systems. Viscosity

(Consult factory for liquid viscosity above 200 cst)

: 0.5 cst to 200 cst

SPECIFICATIONSPulse Output

(Optional)

: 100 PPR, TTL compatible

Type : Positive displacement rotary vane

Casing : Double MATERIALS OF CONSTRUCTION

Sizes and Capsule : 80 mm, single capsule(Models TLD-01 and TLD-02)

: 80 mm, double capsule(Models TLD-03 and TLD-04)

: 100 mm, double capsule(Models TLD-05 and TLD-06)

: 100 mm, triple capsule(Models TLD-07 and TLD-08)

: 150 mm, triple capsule(Models TLD-09 and TLD-10)

Outer Casing

and Cover

: Cast Steel ASTM A216 WCB

Manifold : Cast Steel ASTM A 216 WCB

(for TLD-01 to TLD-06)

Carbon Steel (Fabricated)

(for TLD-07 to TLD-10)

Meter Body : Cast Steel ASTM A 216 WCB

(Optional)Stainless Steel AISI 316 (Optional): 136 - 1500 Ipm

(Models TLD-01 and TLD-02): 205 - 2100 Ipm

(Models TLD-03 and TLD-04): 227 - 2300 Ipm

(Models TLD-05 and TLD-06): 295 - 3000 Ipm

(Models TLD-07 to TLD-10)(Maximum flow rates can be uprated by 30% for ATF andcertain liquids)

Flow Range

Rotor : Aluminium alloy LM-25 (Standard)

Stainless Steel AISI 316 (Optional)

Vanes : Resin impregnated Morganite

CY10C

Bearings : Stainless steel AISI 440 C

Seals : Nitrile (Standard)

Viton (Optional)

End Connections : 150 Class, ANSI B 16.5, FF/RF/300 Class,

: Left hand entry, right handdischarge

(for even meter model nos.)Right hand entry, left handdischarge

(for odd meter model nos.)

Meter Hand ofDischarge (when

facing the counter)Wetted Parts : Stainless Steel AISI 410 and 304

Drive : Positive gear train

Counter : Mechanical - 5 digit reset, 8 digitnon-reset totaliser (Veeder Root 7887)Veeder Root 7887 p

: Mechanical - 5 digit E-typecounter

: Electronic - flameproof counter

GRAPH OF FLOW RATE v/sACCURACY

+0.20+0.15

6 +0.10

g +0.05Unit of Registration : Litres (TLD-01/02)

Deca-litres (TLD-03 to TLD-10)(Other units available on request)

20 40 60 80. 10003

0 -0.05

< -0.10

55 -0-15-0.20

Accuracy : Better than ±0.10%(In accordance with IS:2801)

% FLOWRATE

Test Liquid - Mineral Turpentine Oil (1.2 cSt)

Page 3: Vermont Flow Catalogue Double Case Meter1€¦ · • Solenoid Shut-off Valve Electrical Preset Switch • Temperature Sensor • Card Reader • Grounding Unit Body Material W =

136 150080 mm

(4”)

TLD-01TLD-02

Single Capsule MeterAE F

B0 G’Thru,

N' Nos.on D’ PCD.

ID

c-

Double Capsule MeterAE F

B0 G’Thru,

N’ Nos.on D’ PCD.

u I j.1 C

c

Triple Capsule Meter E AF

:'T'.B

0 G’Thru,N’ Nos.

on D’ PCD.

C

B C D E F G NMin Max

TLD-01TLD-02

80mmCS WCBWCBSingle 136 1500 40000 190.5.5 50000 152.452.4 12525 39090 1919 4

(3")

TLD-03TLD-04

80205 2100 CS WCB 400 190.5 500 152.4 189 460 19 4

(3")

TLD-0505TLD-066

100mm227 2300 CS WCB 500 228.6 560 190.5 189 460 19 8Double

(")

TLD-077TLD-0808

100mm295 3000 CS FAB 500 228.6 560 190.5 265 530 19 8Triple

(4")

TLD-09TLD-10

150mm295 3000 CS FAB 500 279.4 560 241.3 265 530 22 8Triple

(6")

80 mm

(3”)

100 mm

(3”)

(4”)

(6”)

100 mm

150 mm

A B C D E F G N

Page 4: Vermont Flow Catalogue Double Case Meter1€¦ · • Solenoid Shut-off Valve Electrical Preset Switch • Temperature Sensor • Card Reader • Grounding Unit Body Material W =

ACCESSORIES :MECHANICAL

MODELDESIGNATION

• Strainer cum Air Eliminator• Mechanical Preset Valve

Rate of Flow Indicator• Flow Governor• Digital Control Valve• Back Pressure Valve• Slow Close Valve• Air Separator

Counter Swivel• Extended Counter Drive• Proving Tank• Ticket Printer• Siphon Breaker• Insulation Barrier

Double Case PD Flow Meter01 = 80 mm (3"), single capsule, LHD02 = 80 mm (3"), single capsule, RHD03 = 80 mm (3"), double capsule, LHD

04 = 80 mm (3"), double capsule, RHD

05 = 100 mm(4"), double capsule, LHD06 = 100 mm(4"), double capsule, RHD07 = 100 mm(4"), triple capsule, LHD08 = 100 mm(4"), triple capsule, RHD09 = 150 mm(6"), triple capsule, LHD10 = 150 mm(6"), triple capsule, RHD

TLD 01 W N M

OptionsM = MechanicalE = Electronic

ACCESSORIES :ELECTRONIC

Rubber PartsN = NitrileV = Viton

• Pulse TransmitterDigital Preset Counter for Batching

• Digital Counter with Totaliser andRate of Flow Indicator

• Digital Rate of Flow Indicator• 4-20 mAmp Converter• Solenoid Shut-off Valve

Electrical Preset Switch• Temperature Sensor• Card Reader• Grounding Unit

Body Material

W = Cast SteelS = Stainless Steel

To specify type of counter in mechanical Double Case PD

Flow Meters, add suffix "R" for Veeder Root counter andsuffix "E" for E-type counter.

• Specifications are subject to change without notice.• Alldimensions are inmm unless otherwise specified.

Pub. No. 002Issue 2 Rev 1 1-201 5

Vermont Technologies Pvt Ltd.Corporate Office & Operations:

Plot No: PAP- A-8/6, “A” Block, Phase IV, MIDC Chakan, Opp Mahindra Vehicle, Dist:Pune- 410501

Tel. : +91

Email : [email protected]

Website : www.vermonttechnologies.co.in

D-CASE P.D. FLOW METER WITH BATCH CONTROLLER

3 7

9168179461 / +91 9168176683


Recommended