w--Entergy Entergy Nuclear Vermont Yankee, LLC Entergy Nuclear Operations, Inc. 185 Old Ferry Road Brattleboro, VT 05302-0500 April 28, 2004 BVY 04-040 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555 Subject: Vermont Yankee Nuclear Power Station License No. DPR-28 (Docket No. 50-271) Core Opcrating Limits Rcport for Cycle 24 In accordance with Section 6.6.C of the Vermont Yankee Technical Specifications, enclosed is the Core Operating Limits Report (COLR) for Cycle 24. This report presents the cycle-specific operating limits for Cycle 24 of the Vermont Yankee Nuclear Power Station. If you have any questions concerning this transmittal, please contact Mr. Jeffrey T. Meyer at (802) 258-4105. Sincerely, ames M. DeVincentis Manager, Licensing Enclosure cc: USNRC Region I Administrator USNRC Resident Inspector - VYNPS USNRC Project Manager- VYNPS Vermont Department of Public Service 40c1l
Transcript
Page 1: Vermont Yankee Nuclear Power Station, Core Operating ...

w--EntergyEntergy Nuclear Vermont Yankee, LLCEntergy Nuclear Operations, Inc.185 Old Ferry RoadBrattleboro, VT 05302-0500

April 28, 2004BVY 04-040

U.S. Nuclear Regulatory CommissionATTN: Document Control DeskWashington, DC 20555

Subject: Vermont Yankee Nuclear Power StationLicense No. DPR-28 (Docket No. 50-271)Core Opcrating Limits Rcport for Cycle 24

In accordance with Section 6.6.C of the Vermont Yankee Technical Specifications, enclosed isthe Core Operating Limits Report (COLR) for Cycle 24. This report presents the cycle-specificoperating limits for Cycle 24 of the Vermont Yankee Nuclear Power Station.

If you have any questions concerning this transmittal, please contact Mr. Jeffrey T. Meyer at(802) 258-4105.

Sincerely,

ames M. DeVincentisManager, Licensing

Enclosure

cc: USNRC Region I AdministratorUSNRC Resident Inspector - VYNPSUSNRC Project Manager- VYNPSVermont Department of Public Service

40c1l

Page 2: Vermont Yankee Nuclear Power Station, Core Operating ...

Vermont Yankee Nuclear Power Station

Cycle 24

Core Operating Limits Report

Revision 0

April 2004

Prepared

Reviewed

Approved

-

Lob \!v ~Reactor Engineer 9nt Sign)

Reactor Engineer (Print/Signj

3 ; 111,u r Un4Superintendent, Reactor Engiring (Print/Sign)

-

-

Date

Date

Date-

Reviewed-

* Approved

Approved

,1?7&'--MT, kAbCAJ4 MorVq M. f-ka/.e M OWL,-6o( Yf-/6-o(Plant-Opel Review Committee (Print/Sige) Date

General Manager, Plant Operations (Print/Sign) Date

_, K t. iA', ~ a i4/ / o4Site Vice Presid t!i /Sign) Date /

Page 3: Vermont Yankee Nuclear Power Station, Core Operating ...

REVISION RECORD

Cycle

24

Revision

0

Date Description

Cycle 24 revision.04/2004

Cycle 24 COLRRevision 0Revision RecordPage i of i

Vermont Yankee Nuclear Power Station

Page 4: Vermont Yankee Nuclear Power Station, Core Operating ...

ABSTRACT

This report presents cycle-specific operating limits for the operation of Cycle 24 of the Vermont

Yankee Nuclear Power Station as specified in Technical Specification 6.6.C. The limits included

in the report are average planar linear heat generation rate, linear heat generation rate, minimum

critical power ratio, and thermnal-hydraulic stability exclusion region.

The requirement of Technical Specifications Table 3.2.5 pertaining to the rod block monitor

(RBM) setpoint equation maximum value of N and maximum allowable RBM rod block setpoint

limit are included in this report.

Cycle 24 COLRRevision 0AbstractPage i of i

Vermont Yankee Nuclear Power Station

Page 5: Vermont Yankee Nuclear Power Station, Core Operating ...

TABLE OF CONTENTS

Paie

LIST OF TABLES ........... ii

LIST OF FIGURES ........... iii

1.0 INTRODUCTION .1

2.0 CORE OPERATING LIMITS .2

2.1 Average Planar Linear Heat Generation Rate Limits (APLHGR) .2

.2.2. Minimum Critical Power Ratio (MCPR) Limits ... 2

2.3 Linear Heat Generation Rate (LHGR) Limits .4

2.4 Thermal-Hydraulic Stability Exclusion Region .5

2.5 Power/Flow Map .8

2.6 Single Loop Operation .8

2.7 Rod Block Monitoring .9

REFERENCES ......... 20

Cycle 24 COLRRevision 0Table of ContentsPage i of iii

Vermont Yankee Nuclear Power Station

Page 6: Vermont Yankee Nuclear Power Station, Core Operating ...

TABLE OF CONTENTS (Continued)

LIST OF TABLES

TitleNumber Page

Table 2.1-1

Table 2.1-2

MAPLHGR Limits forGE1 4-P 1 ODNAB426-16G6.0-1 OOT-1 50-T6-2682Fuel Bundle No. 2682 .................................. 9

MAPLHGR Limits forGE14-PIODNAB390-14GZ-IOOT-150-T6-2683Fuel Bundle No. 2683 .................................. 9

Table 2.1-3

Table 2.1-4

Table 2.1-5

MAPLHGR Limits forGE14-P1 ODNAB388-17GZ-I OOT-1 50-T6-2684Fuel Bundle No. 2684 ............. 10

MAPLHGR Limits forGE9B-P8DWB335-1 OGZ-80U-150-T6Fuel Bundle No. 3615 ............. 10

MAPLHGR Limits forGE9B-P8DWB335-1 1GZ-80U-1 50-T6Fuel Bundle No. 3616 ............. 11

* Table 2.1-6

Table 2.1-7

MAPLHGR Limits forGE13-P9DTB386-1 lG4.0/1G3.0-1 OOT-146-T6-3958Fuel Bundle No. 3958 ............. 11

MAPLHGR Limits forGE13-P9DTB225-NOG-IOOT-146-T6-2571Fuel Bundle No. 2571 .............. ; 12

Table 2.1-8

Table 2.1-9.

Table 2.1-10

MAPLHGR Limits forGE14-PIODNAB394-7G5.0/6G4.0-1 OOT-150-T6-2566Fuel Bundle No. 2566 ............. 12

MAPLHGR Limits forGE14-PI ODNAB394-8G5.016G4.0-1 OOT-150-T6-2595Fuel Bundle No. 2595 ............. 13

MAPLHGR Limits forGE14-P1 ODNAB394-12G5.0-1 OOT-1 50-T6-2596Fuel Bundle No. 2596 ............. 13

Table 2.2-1

Table 2.2-2

Cycle 24 Rated MCPR Operating Limits (OLMCPR) .............................. 14

D2MW C.+--;-+ 1AD1%AY, 1Jv"UUII .......... 1T

Cycle 24 COLRRevision 0Table of ContentsPage ii of iii

Vermont Yankee Nuclear Power Station

Page 7: Vermont Yankee Nuclear Power Station, Core Operating ...

Number

2.2-1

2.2-2

2.3-l

2.3-2

2.4-I

TABLE OF CONTENTS (Continued)

LIST OF FIGURES

Title Page

Power Dependent K (P) / MCPR (P) Limits ................................... 15

Flow Dependent MCPR Operating Limit MCPR (F) .1................................... l 6

Power Dependent LHGRFAC (P) Multiplier ................................... 17

LHGR Flow Factor LHGRFAC (F) ....................... ; 18

Limits of Power/Flow Operation ...................... 19

Cycle 24 COLRRevision 0Table of ContentsPage iii of iii

Vermont Yankee Nuclear Power Station

Page 8: Vermont Yankee Nuclear Power Station, Core Operating ...

1.0 INTRODUCTION

This report provides the cycle-specific limits for operation of the Vermont Yankee NuclearPower Station in Cycle 24. It includes the limits for the average planar linear heat generationrate, linear heat generation rate, minimum critical power ratio, and thermal-hydraulic stabilityexclusion region. If any of these limits are exceeded, action will be taken as defined in theTechnical Specifications.

As specified in Technical Specifications Table 3.2.5, the rod block monitor (RBM) setpointequation maximum value of N and maximum allowable RBM rod block setpoint limit areincluded in this report.

This Core Operating Limits report for Cycle 24 has been prepared in accordance with therequirements of Technical Specifications 6.6.C. The core operating limits have been developedusing the NRC-approved methodologies listed in References 3.1 through 3.4. Themethodologies are also listed in Technical Specification 6.6.C. The bases for these limits are inReferences 3.5 through 3.10.

Cycle 24 COLRRevision 0Page I of 20

Vermont Yankee Nuclear Power Station

Page 9: Vermont Yankee Nuclear Power Station, Core Operating ...

2.0 CORE OPERATING LIMITS

The Cycle 24 operating limits have been defined using NRC-approved methodologies. Cycle 24must be operated within the bounds of these limits and all others specified in the TechnicalSpecifications.

2.1. Average Planar Linear Heat Generation Rate Limits (APLHGR) (T.S. 3.11 .A)

APLHGR is applicable to a specific planar height and is equal to the sum of the linearheat generation rate (LHGR) for all of the fuel rods in the specific bundle at the specificheight divided by the number of fuel rods in the fuel bundle at the height.

The maximum APLHGR (MAPLHGR) limit is a function of reactor power, core flow,fuel type, and average planar exposure. The cycle dependent limits are developed usingNRC approved methodology described in References 3.1 and 3.3. The MAPLHGR limitensures that the peak clad temperature during a LOCA will not exceed the limits asspecified in 10CFR50.46 (b) (1) and that the fuel design analysis criteria defined inReferences 3.1 and 33 will be met.

Tables 2.1-1 through 2.1-10 provide a limiting composite of MAPLHGR values for eachfuel type, which envelope the lattice MAPLHGR values employed by the processcomputer (Reference 3.6). When hand calculations are required, these MAPLHGRvalues are used for all lattices in the bundle.

For single recirculation loop operation, the limiting values shall be the values from theseTables listed under the heading "Single Loop Operation." These values are obtained bymultiplying the values for two loop operation by 0.82 (Reference 3.6).

2.2. Minimum Critical Power Ratio (MCPR Limits (T.S. 3.1 1.C)

MCPR is the smallest Critical Power Ratio (CPR) that exists in the core for each type offuel and shall be equal to, or greater than the Operating Limit MCPR (OLMCPR), whichis a function of Core Thermal Power, Core Flow, Fuel Type, and Scram Time (Tau).

The rated Operating Limit MCPR at steady-state rated power and increased core flowoperating conditions is derived from the cycle specific fuel cladding integrity SafetyLimit MCPR and the delta CPR, as determined from the most limiting transient event.The rated OLMCPR will ensure that the Safety Limit MCPR is not exceeded during anyabnormal operational occurrence (AOO) (Reference 3.6).

The rated OLMCPR for two loop and single loop operation is documented in Table 2.2-1and is dependent on scram time (Tau) surveillance data at position 36 (Reference 3.8).

Cycle 24 COLRRevision 0Page 2 of 20

Vermont Yankee Nuclear Power Station

Page 10: Vermont Yankee Nuclear Power Station, Core Operating ...

Determination of Tau:

i. First, Tre shall be determined:

* N~r,I~f

I-1

where:

n = number of scram time tests thus far this cycle,

N, = number of active rods measured in surveillance i, and

r, = average scram time to position 36 dropout of all rods measured in surveillance i.

ii. Second, Tr shall be determined:

N1

rB = /+. 1.65 aN

where:

p = 0.830 = mean of the distribution for average scram insertion time to position 36dropout used in the ODYN Option B analysis.

a= 0.01 9 = standard deviation of the distribution for average scram insertion time toposition 36 dropout used in the ODYN Option B analysis.

Ni = number of active rods measured during the first surveillance test at BOC.

iii. Third, determine the OLMCPR, as follows:

If -rT -rB, then OLMCPRop 0..B from Table 2.2.1 may be used.

If Taive> TB, then a new OLMCPR shall be calculated:

OLMCPRNW = OLMCPR0 p110,B + ae L -CTB (o RcPR pA- OLMCPROPj,1 0 B)TrA - V piBn

Cycle 24 COLRRevision 0Page 3 of 20

Vermont Yankee Nuclear Power Station

Page 11: Vermont Yankee Nuclear Power Station, Core Operating ...

where:

OLMCPRoptilA =Option A OLMCPR from Table 2.2.1 based on Option A analysisusing full core scram times listed in Technical Specification 3.3.C. 1.2.

OLMCPRoptionB =Option B OLMCPR from Table 2.2.1 based on Option B analysisdescribed in Reference 3.1.

A = 1.096 seconds = Technical Specification 3.3.C.1.2 core average scram time todrop-out of position 36.

The OLMCPR is the greater of the flow and power dependent MCPR operating limits,MCPR (F) and MCPR (P).

OLMCPR = MAX (MCPR (F), MCPR (F))

The flow dependent MCPR operating limits, MCPR (F), is provided in Figure 2.2-2.

For core thermal powers less than or equal to 30%, the power dependent MCPRoperating limit, MCPR (P), is provided in Figure 2.2-1. Above 30%, MCPR (F) is theproduct of the rated OLMCPR presented in Table 2.2-1 and the K (P) factor presented inFigure 2.2-1.

Cycle exposure dependent limits are provided through the end of rated exposure point,which is expected to be the maximum exposure attainable at full power during ICFoperation. Coastdown operation is allowable down to 40% rated CTP.

For single recirculation loop operation, the MCPR limits at rated flow shall be the valuesfrom Table 2.2-1 listed under the heading, "Single Loop Operation." The single loopvalues are obtained by adding 0.02 to the two loop operation values (TS 1.IA.1).

2.3. Linear Heat Generation Rate (LHGR) Limits (T.S. 3.11 .B)

LHGR is the heat generation rate per unit length of fuel rod. It is the integral of the heatflux over the heat transfer area associated with the unit length. By maintaining theoperating LHGR below the applicable LHGR limit, it is assured that allthermal-mechanical design basis and licensing limits for the fuel will be satisfied.

The maximum LHGR limit is a function of reactor power, core flow, fuel and rod type,and fuel rod nodal exposure. The limit is developed using NRC approved methodologydescribed in Reference 3.1 to ensure the cladding will not exceed its yield stress and thatthe fuel thermal-mechanical design criteria will not be violated during any postulatedtransient events.

Cycle 24 COLRRevision 0Page 4 of 20

Vermont Yankee Nuclear Power Station

Page 12: Vermont Yankee Nuclear Power Station, Core Operating ...

-During reactor power operation, the LHGR of any rod in any fuel bundle at any axiallocation shall not exceed the rated power and rated core flow limits (LHGRId) for eachfuel and rod type as a function of fuel rod nodal exposure listed in Reference 3.7.

The LHGR limits for the fuel pin axial locations with no gadolinium and maximumgadolinium concentration listed in Reference 3.7 are expected to operate near the LHGRlimits.

There are also fuel pins with axial locations that have gadolinium concentrations that areless than the maximum concentration anywhere in the bundle. The LHGR limits forthese axial locations range uniformly between the case of no gadolinium and the mostlimiting gadolinium concentration and are listed in Reference 3.9.

For other than rated power and flow conditions (below 25% core thermal power thermallimit calculation is not required), the applicable limiting LHGR values for each fuel typeis the smaller of the power and flow dependent LHGR limits multiplied by the applicablepower and flow adjustment factor or the LHGR limit multiplied by 0.82 when in singleloop operation.

LHGR limit = MN (LHGR (P), LHGR (F)).

Power-dependent LHGR limit, LHGR (P), is the product of the LHGR power dependentLHGR limit adjustment factor, LHGRFAC (P), shown in Figure 2.3-1 and the LHGRS.

LHGR (P) = LHGRFAC (P) x LHGRI

The flow-dependent LHGR limit, LHGR (F), is the product of the LHGRflow dependentLHGR limit adjustment factor, LHGRFAC (F), shown in Figure 2.3-2 and the LHGRW.

LHGR (F) = LHGRFAC (F) x LHGRa

2.4. Thermal-Hydraulic Stability Exclusion Region (T.S. 3.6.0)

For Cycle 24, based on decay ratios at the most limiting point on the power/flow, thepredominate oscillation mode is core-wide. Normal plant operation is not allowed insidethe bounds of the exclusion region defined in Figure 2.4-1. These power and flow limitsare applicable for Cycle 24. Operation inside of the exclusion region may result in athermal-hydraulic oscillation. Intentional operation within the buffer region is notallowed unless the Stability Monitor is operable. Otherwise, the buffer region isconsidered part of the exclusion region (Reference 3.6).

The coordinates of the Exclusion Region are as follows:

Point Power (%) Flow (%)

A 77.4 50.0

B 45.0 31.3

Cycle 24 COLRRevision 0Page 5 of 20

Vermont Yankee Nuclear Power Station

Page 13: Vermont Yankee Nuclear Power Station, Core Operating ...

-- .

The equation for the boundary is as follows:

where,

P = a core thermal power value on the Exclusion Region boundary (% of rated),W = the core flow rate corresponding to power, P, on the Exclusion Region

boundary (% of rated),PA = core thermal power at State Point A (% of rated),PB = core thermal power at State Point B (% of rated),WA = core flow rate at State Point A (% of rated),WD = core flow rate at State Point B (% of rated),

The range of validity of the fit is: 31.3%<0 /oFlow <50.0%

The coordinates of the Buffer Region are as follows:

Point Power (%) Flow (%)

C 81.8 55.0

D 40.0 31.3

The generic equation used to generate the 5% buffer zone exclusion region boundary is:

where,

P = a core thermal power value on the Buffer Zone boundary (% of rated),W = the core flow rate corresponding to power, P. on the 5% Buffer Zone

boundary (% of rated),Pc = core thermal power at State Point C (% ofrated),PD = core thermal power at State Point D (% of rated),Wc = core flow rate at State Point C (% of rated),WD = core flow rate at State Point D (% of rated),

The range of validity of the fit is: 31.3% <0/oFlow <55.0%.

Cycle 24 COLRRevision 0Page 6 of 20

Vermont Yankee Nuclear Power Station

Page 14: Vermont Yankee Nuclear Power Station, Core Operating ...

2.5. Power/Flow Mag

Power operation, with respect to Core Thermal Power/Total Core Flow combinations, isallowed within the boldly outlined area of Figure 2.4-1. This area is bounded by thefollowing lines:

* Minimum Pump Speed Line; This line approximates operation at minimum pumpspeed. Plant start-up is performed with the recirculation pumps operating atapproximately 20% speed. Reactor power level will approximately follow thisline during the normal control rod withdrawal sequence.

* Minimum Power Line; This lines approximates the interlock that requires recircpump speed to be at a minimum below 20% of feedwater flow. This interlockensures NPSH requirements.are met.

* Natural Circulation Line; The operating state the reactor follows along this linefor the normal control rod withdrawal sequence in the absence of recirculationpump operation.

* Exclusion Region - The exclusion region is a power/flow region where aninstability can occur. The boundary for the exclusion region is established throughuse of an analysis procedure which is demonstrated to be conservative relative toexpected operating conditions.

* 5% Buffer Region Boundary; The Buffer Region is determined by adjusting theendpoints of the Exclusion Region and increasing the flow on the highest rod lineby 5% and decreasing power on the natural circulation line by 5%.

* Rated Power Line and MELLLA Boundary; These lines provide the upper powerlimit and operating domain assumed in transient analyses.

* ICF Boundary; This line represents the highest allowable analyzed core flow. Theanalysis in Reference 3.4 supports the maximum attainable core flow beingapproximately 107% of rated core flow.

* 108% rod line; this line represents the ELLLA operating boundary and is themaximum load line allowed in single loop operation.

2.6. Single Loop Operation

SLO was not analyzed for operation in the MELLLA region. The power/flow operatingcondition for Single Loop Operation (SLO) is core power less than 1239 MWTh(77.77%CTP),'core flow less than 26.35 MU/hr (54.9%) and maximum rod line less than108%. (References 3.2 and 3.11)

Cycle 24 COLRRevision 0Page 7 of 20

Vermont Yankee Nuclear Power Station

Page 15: Vermont Yankee Nuclear Power Station, Core Operating ...

2.7. Rod Block Monitoring

The rod block monitor (RBM) setpoint equation maximum value of N and maximumallowable RBM rod block setpoint limit are listed in Table 2.2-2.

Cycle 24 COLRRevision 0Page 8 of 20

Vermont Yankee Nuclear Power Station

Page 16: Vermont Yankee Nuclear Power Station, Core Operating ...

Table 2.1-1

MAPLHGR Limits for GE14-PIODNAD426-16G6.0-iOOT-150-T6-2682Fuel Bundle No. 2682

Average Planar Exposure(GWd/ST)

0.00

19.12

57.61

63.50

MAPLHGR (kW/ft)

Two Loop Operation Single Loop Operation'

12.82 10.51

12.82 10.51

8.00 6.56

5.00 4.10

Technical Specification References: 3.6.G.la and 3.11 .A.

] MAPLHGR for single loop operation is obtained by multiplying MAPLHGR for two loop operationby 0.82.

Table 2.1-2

MAPLHGR Limits for GE14-PIODNAB390-14GZ-IOOT-150-T6-2683Fuel Bundle No. 2683

Average Planar Exposure(GWd/ST)

0.00

19.12

57.61

63.50

MAPLHGR (kW/ft)

Two Loop Operation Single Loop Operation'

12.82 10.51

12.82 10.51

8.00 6.56

5.00 4.10

Technical Specification References: 3.6.G.la and 3.11.A.

MAPLHGR for single loop operation is obtained by multiplying MAPLHGR for two loop operation by0.82.

Cycle 24 COLRRevision 0Page 9 of 20

Vermont Yankee Nuclear Power Station

Page 17: Vermont Yankee Nuclear Power Station, Core Operating ...

Table 2.1-3

MAPLHGR Limits for GE14-PIODNAB388-17GZl- OOT-1 50-T6-2684Fuel Bundle No. 2684

Average Planar Exposure(GWd/ST)

0.00 ;

19.12

57.61

63.50

MAPLHGR (kW/ft)

Two Loop Operation Single Loop Operation'

12.82 10.51

12.82 10.51

8.00 6.56

5.00 4.10

Technical Specification References: 3.6.G.la and 3.11.A.

l MAPLHGR for single loop operation is obtained by multiplying MAPLHGR for two loop operation by0.82.

Table 2.1-4

MAPLHGR Limits for GE9B-P8DWB335-1OGZ-80U-150T-T6Fuel Bundle No. 3615

Average Planar Exposure(GWd/ST)

0.00

16.58

48.08

54.43

MAPLHGR (kW/ft)

Two Loop Operation Single Loop Operations

13.90 11.39

13.90 11.39

9.20 7.54

6.00 4.92

Technical Specification References: 3.6.G.la and 3.1 I.A.

MAPLHGR for single loop operation is obtained by multiplying MAPLHGR for two loop operation by0.82.

Cycle 24 COLRRevision 0Page 10 of 20

Vermont Yankee Nuclear Power Station

Page 18: Vermont Yankee Nuclear Power Station, Core Operating ...

Table 2.1-5

MAPLHGR Limnits for GE9B-P8DWB335-1 GZ-80U-150T-T6Fuel Bundle No. 3616

Average Planar Exposure(GWd/ST)

0.00

16.58

48.08

54.43

MAPLHGR (kW/ft)

Two Loop Operation Single Loop Operation'

13.90 11.39

13.90 11.39

9.20 7.54

6.00 4.92

Technical Specification References: 3.6.G.la and 3.1 I.A.

MAPLHGR for single loop operation is obtained by multiplying MAPLHGR for two loop operation by0.82.

Table 2.1-6

MAPLHGR Limits for GE13-P9DTB386-11 G4.0/1 03.0-1OOT-1 46-T6-3958Fuel Bundle No. 3958

Average Planar Exposure(GWd/S')

0.00

13.24

21.77

26.95

32.66

56.70

63.50

Two Loop Opel

13.40

13.40

13.20

13.20

12.70

9.00

6.40

MAPLHGR (kW/ft)

ration Single Loop Operation

10.98

10.98

10.82

10.82

10.41

7.38

5.24

Technical Specification References: 3.6.G.la and 3.1 l.A.

lMAPLHGR for single loop operation is obtained by multiplying MAPLHGR for two loop operation by0.82.

Cycle 24 COLRRevision 0Page 11 of 20

Vermont Yankee Nuclear Power Station

Page 19: Vermont Yankee Nuclear Power Station, Core Operating ...

Table 2.1-7

MAPLHGR Limits for GE13-P9DTB225-NOG-IOOT-146-T6-2571Fuel Bundle No. 2571

Average Planar Exposure(GWd/STi)

0.00

13.24

21.77

26.95

32.66

'56.70

63.50

MAPLHGR (kW/ft)

Two Loop Operation Single Loop Operation'

13.40 10.98

13.40 10.98

13.20 10.82

13.20 10.82

12.70 10.41

9.00 7.38

6.40 5.24

Technical Specification References: 3.6.G.la and 3.1 1A.

t MAPLHGR for single loop operation is obtained by multiplying MAPLHGR for two loop operation by0.82.

Table 2.1-8

MAPLHGR Limits for GE14-P1ODNAB394-7G5.0/6G4.0-l OOT-1 50-T6-2566* Fuel Bundle No. 2566

Average Planar Exposure(GWdIST)

0.00

19.12

57.61

63.50

MAPLHGR (kW/ft)

Two Loop Operation Single Loop Operation'

12.82 10.51

12.82 10.51

8.00 6.56

5.00 4.10

Technical Specification References: 3.6.G.la and 3.11 A.

'MAPLHGR for single loop operation is obtained by multiplying MAPLHGR for two loop operation by0.82.

Cycle 24 COLRRevision 0Page 12 of 20

Vermont Yankee Nuclear Power Station

Page 20: Vermont Yankee Nuclear Power Station, Core Operating ...

Table 2.1-9

MAPLHGR Limits for GE14-PI ODNAB394-8G5.0/6G4.0-1 OOT-1 50-T6-2595Fuel Bundle No. 2595

Average Planar Exposure* (GWd/ST)

0.00

19.12

57.61

63.50

MAPLHGR (kW/ft)

Two Loop Operation Single Loop Operation1

12.82 10.51

12.82 10.51

8.00 6.56

5.00 4.10

Technical Specification References: 3.6.G.la and 3.11 A.

MAPLHGR for single loop operation is obtained by multiplying MAPLHGR for two loop operation by0.82.

Table 2.1-10

MAPLHGR Limits for GE] 4-PIODNAB394-12G5.0-1 OOT-1 50-T6-2596Fuel Bundle No. 2596

Average Planar Exposure MAPLHGR (kW/ft)(GWdIST) Two Loop Operation Single Loop Operation'

0.00 12.82 10.51

19.12 12.82 10.51

57.61 8.00 6.56

63.50 5.00 4.10

Technical Specification References: 3.6.G.la and 3.1 l.A.

l MAPLHGR for single loop operation is obtained by multiplying MAPLHGR for two loop operation by0.82.

Cycle 24 COLRRevision 0Page 13 of 20

Vermont Yankee Nuclear Power Station

Page 21: Vermont Yankee Nuclear Power Station, Core Operating ...

Table 2.2-1

Cycle 24 Rated MCPR Operating Limits (OLMCPR)

Option

Option A

Option B

Cycle ExposureRan09 e

O to 11915 MWd/St

O to 11915 MWd/St

Two Loop Single LoopOperation 2 Operation

1.60 1.62

1.43 1.45-

.

Source: References 3.6 and 3.7.

1 The MCPR operating limit is increased by 0.02 for single loop operation.2 The two loop MCPR operating limits bound ICF operation throughout the cycle.

Table 2.2-2RBM Setpoint 3

Maximum Value of 'WI in RBM Setpoint Equation - 62.

Maximum Allowable RBM Rod Block setpoint -112% power.

Source: Reference 3.10

Technical Specification References: Table 3.2.5.

3 The Rod Block Monitor (RBM) trip setpoints are determined by the equation shown inTable 3.2.5 of the Technical Specifications.

Cycle 24 COLRRevision 0Page 14 of 20

Vermont Yankee Nuclear Power Station

Page 22: Vermont Yankee Nuclear Power Station, Core Operating ...

Power Dependent K (P) t MCPR (P) Lirnits

2.60

>6OU0 Flow I I I I I I I I2AO

2.20

2.00

A.)0 1.80

1.60

S 60% Flow

~N_ _ I

Operating limit MCPR (P) - K(P) x Operating Limit MCPR (100)

For P < 25%: No Thermal Limits Required

For 25% 5 P < 30%/O, > 60% Flow.OLMCPR (P) = 2.48- 0.034 x (P - 25%.)

For 25% 5 P < 30%, S 60Yo Flow:OLMCPR (P) - 2.07 - 0.026 x (P - 25%)

For 30% S P < 45%: K (P) - 1.55 - 0.0135 x (P -25%)

For4S% 5P < 100%: K (P) 1.28 - 0.00509 x (P -45%)

ForP 2100%: K(P)=1.00

1.40

1. ZU I I

- .1 .0 0 t25

I I II . I I. I . - ,

-' , Z _

30 35 40 45 50 55 60 65

-Power (0h Rated)

70 75 80 85 90 95 100

Figure 2.2-1

Power Dependent K (P) / MCPR (P) Limits(Technical Specification Reference 3.11 .C)

Cycle 24 COLRRevision 0Page 15 of 20

Vermont Yankee Nuclear Power Station

Page 23: Vermont Yankee Nuclear Power Station, Core Operating ...

Flow Dependend MCPR Operating Limit MCPR(F)I . ,.

1.80

1.70

U 1.60

2E

bo

_1.50

0

U 1.40

c

a)

aL 1.300

L..

* 4 4 4

__t___

For W (C) (Ih Rated Core Flow) > 30%

MCPR(F)= MAX (120,A (F) * (W(C) I 100) +B(F))

Max Ri FlowS 109.5%

A (F) - - 0.602 B (F) = 1.747. . .

I Maximum FlowlRate 10________ .4

I20 I I_inI

20 30 40 50 60 70

Core Flow(% Rated)

80 90 100 110 120

Figure 2.2-2

Flow Dependent MCPR Operating Limit MCPR (F)(Technical Specification Reference 3.11 .C)

Cycle 24 COLRRevision 0Page 16 of 20

Vermont Yankee Nuclear Power Station

Page 24: Vermont Yankee Nuclear Power Station, Core Operating ...

6

9,

Power Dependant LHGRFAC(P) Multiplier

1.00 - -

0.90 - - - - - .

:5 60% Flow_0 . 80- / -__ __ __

0 /7 -LHGR (P) LHGRFAC (P) x LHGRstdWhere LHGRstd = Rated LHGR limits

- - - -For PC25%: No Thermal Limits Required

For 25% 5 P < 30%, > 60% Flow:

0.50 . - -0 - -___ . _ LHGRFAC (P) = 0.586 + 0.0084 x (P.25%)

For 25% 5 P < 30%.5 S60% Fow:

0.40 - LHGRFAC (P) = 1.0 + 0.00523 x (P-1 00%)_ _ For 30% S P < I100%_

: 30 LHGRFAC (P) = 1.0 + 0.00523 x (P-1 00%/)….… - For P 2100%: LHGRFAC (P) 1.0

0.20-

25 30 35 40 45 50. 55 60

Power (o/6 Rated)

65 70 75 80 85 DO 95 1W0

Figure 2.3-1

Power Dependent LHGRFAC (P) Multiplier(Technical Specification Reference 3.11 .B)

Cycle 24 COLRRevision 0Page 17 of 20

Vermont Yankee Nuclear Power Station

Page 25: Vermont Yankee Nuclear Power Station, Core Operating ...

I V

LHGR Flow Factor LHGRFAC (F)

n

0rY

S

.2

1.00 __ __ _

Maximum Flow -109.5%0.90 . _

0.80

0.70 .,LHGR (F) - LHGRFAC (F) x LHGRstd

I LHUlGRstd- STANDARD LHGR LIMITS0.60 _

FoiW (% Raed Core Flow) > 306XAOd Max RunoutFlowS 109.5%

0.50 __ __ _

LGEPAC (F) - The Mininlum of ETHER 1.0OR (0.8737x(W/100)+ 0.2779)

0.40- W- Rated Core Flow

0.3020 30 40 50 s0 70

Core Flow (Y Rated)

80 90 100 110 120

Figure 2.3-2

LHGR Flow Factor LHGRFAC (F)(Technical Specification Reference 3.11 .B)

Cycle 24 COLRRevision 0Page 18 of 20

Vermont Yankee Nuclear Power Station

Page 26: Vermont Yankee Nuclear Power Station, Core Operating ...

Cycle 24 Power/Flow Map110

100

90

80

.9A 70

y 60is

. s0

96

4 0

9 0E

20

10

00 10 20 30 40 50 60 70 80 9s 100 110

Core Flow (o Ratd)

Figure 2.4-1

Limits of Power/Flow Operation(Technical Specification Reference 3.6.J)

Cycle 24 COLRRevision 0Page 19 of 20

Vermont Yankee Nuclear Power Station

Page 27: Vermont Yankee Nuclear Power Station, Core Operating ...

3.0 REFERENCES

3.1. Report, General Electric, General Electric Standard Application for Reactor Fuel(GESTAR H). NEDE-2401 1-P-A-14, June 2000 (Proprietary).

3.2. Report, GE, Vermont Yankee Nuclear Power Station APRM/RBMITechnicalSpecifications/Maximum Extended Load Line Limit Analysis (ARTS/MELLLA),NEDC-33089P, March 2003 (Proprietary).

3.3. Report, GE, Entergy Nuclear Operation Incorporated Vermont Yankee Nuclear PowerStation Extended Power Uprate - Task T0407 - ECCS-LOCA SAFERIGES.GE-NE-0000-0015-5477-01, July 2003.

3A. Report, Vermont Yankee Nuclear Power Station Increased Core Flow Analysis,NEDC-32791P, February 1999.

3.5. Report, Global Nuclear Fuels, Cycle Management Report for Vermont Yankee NuclearPower Station Cycle 24. 0000-0026-5068-CMR, Rev. 0, March 2004 (Proprietary).

3.6. Report, Global Nuclear Fuels, Supplemental Reload Licensing Report for VermontYankee Nuclear Power Station Reload 23 Cycle 24. 0000-0016-6419-SRLR, Rev. 0,March 2004.

3.7. Report, Global Nuclear Fuels, Fuel Bundle Information Report for Vermont YankeeNuclear Power Station Reload 23 Cycle 24 0000-0016-6419-FBIR, Rev. 0, March 2004(Proprietary).

3.8. Letter, Global Nuclear Fuels, William H. Hetzel (GNF) To Dave Mannai (VYNPC),Vermont Yankee Option B Licensing Basis WHV: 2001-023, November 9, 2001.

3.9. Report, GNF, Vermont Yankee Cycle 24 3D Monicore Databank, 0000-0026-457, Rev 0,April 04.

3.10. VYDC 2003-015, ARTS/MELLLA Implementation.

3.11. Report, GE, Vermont Yankee Nuclear Power Station Single Loop OperationNEDO-30060, February 1983.

Cycle 24 COLRRevision 0Page 20 of 20