REV 03 QSG 892-00089 REV03 High Voltage High Voltage High Voltage High Voltage 6.5” 10” 10” High Voltage High Voltage 6.5” NOTE: This guide does not provide detailed installation, safety or operational instructions. See the Versillum Light Dimmer User Manual for complete information. Please scan the QR Code to access the complete User Manual or visit the Cumberland website: http:// www.cumberlandpoultry.com 1. Set toggle switch for Zone 1 and Zone 2 to manual mode (Man). The toggle switch light will change from green (Auto) to red (Manual). NOTE: To optimize light performance, the Versillum includes 3 types of waveform curves for lights. They are called (T), (L), and (C) curves. The most commonly used waveform is (T) and is the factory default setting. If the lights are flickering, you may need to change the waveform curve by setting the DIP switches located on the back of the cover plate. Refer to Wiring Diagram for settings. 2. Turn the knob clockwise until the light is at 100%, then slowly turn the knob counterclockwise and make sure the lights dim properly without flickering at any of the percentage points. If the lights do not flicker, go to Step 8. 3. If the lights do not dim properly, try waveform curve (L) by setting the DIP switches. Important: During installation and during first trials with low load of lights, it is important to change the waveform curve if a lot of overcurrent (OVC message and triangle warning symbol) detections occurs. A good setup has to limit the flickering and the current peaks during dimming. 4. Repeat Step 2. 5. If the lights do not dim properly, try waveform curve (C) by setting the DIP switches. 6. Repeat Step 2. 7. Contact technical support for more help if lights still do not dim properly. 8. Set the Min. and Max. Intensity: Minimal Intensity = All lights are ON at their lowest intensity. Maximum Intensity = The lowest voltage where lights are ON at full intensity. a. Press and hold the Set button (1) for 7 seconds. b. Make sure the toggle switch (2) is set to manual for the Zone you want to change. NOTE: The knob (3) will not work unless the switch is in the Manual position. c. Use the knob (3) to increase or decrease the value. d. Press the Set button (1) to accept the new value or the Scenario button (5) to cancel. Only properly trained service personnel may perform installation and service procedures. (In other words: electricians, service personnel employed by or active in an organization, business, or service). All power must be turned off prior to wiring, installing, servicing, setting the bypass switches or the DIP switches. More than one disconnect is required to de-energize power to the Versillum Light Dimmer. Make sure to separate high voltage wiring from low voltage (Class 2) control wiring. Use copper wires only. CFL and CCFL lamps must be ELV ballast type (electronic only) 1. To adjust light intensity manually, place the switch of the corresponding Zone to the (Man) position and turn the knob. 2. To adjust light intensity automatically, place the switch of the corresponding Zone to the (Auto) position and set the 0-10V output from the master controller. Refer to the user manual to configure the light type control, the Min. and Max. intensity, the skipped points, to merge the 0-10V inputs on Zone 1, and to merge the knob control. GSI Electronics Inc. 5200 Armand Frappier Saint-Hubert, Qc Canada J3Z 1G5 Phone: 1-877-926-2777 E-mail: [email protected] Versillum Light Dimmer Quick Start Guide 1 - NOTICES 3 - INSTALLATION WARNING: Read the following text carefully; it contains important information which, if ignored, may cause the controller to operate improperly. High Voltage. Hazard of electrical shock. Protective Earth Ground Terminal. Primarily used for protective earth terminals. 2 - SAFETY SYMBOLS 4 - SETUP 5 - BASIC OPERATION Minimal Intensity Maximum Intensity The Versillum Light Dimmer must be mounted in a location that has sufficient air circulation around the box. Minimum clearance is 25” W x 29.5” H to ensure protection against electrical conducted noise. 1. Mount the Versillum on the wall using the minimum clearance and wire it referring to the wiring diagram. Install using 4 lag screws. 1. Man - Indicates manual mode operation 2. The (+) indicates that a custom curve is being used (Min. and Max. have been set) 3. White light bulb indicates that the lights are ON. 4. Auto - indicates automatic mode operation and lights are being controlled by another controller 5. The (T) indicates that lights are using (T) mode waveform. 6. Black light bulb indicates lights are OFF 7. The number indicates the percentage of voltage being used by lights 8. The percentage bar indicates the percentage of voltage being used or if the light is OFF 9. Indicates the Amps being used by the lights Item Description 1 Zone 1 settings display area 2 Zone 2 settings display area 3 Set button 4 Scenario button 5 Zone 1 intensity knob 6 Zone 1 mode switch 7 Zone 2 intensity knob 8 Zone 2 mode switch 9 Manual mode indicator light 10 Auto mode indicator light Controls and Display Layout Display Layout EN
Transcript
Page 1: Versillum Light Dimmer - Quick Start Guide€¦ · Si les lumières ne s’atténuent pas correctement, essayez la courbe de forme d’onde (L) en réglant les commutateurs DIP. Important:

REV 03

QSG 892-00089 REV03

FR ES

High Voltage

High Voltage

Hig

h Vo

ltage

Hig

h Vo

ltage

6.5”

10”

10”

Hig

h Vo

ltage

Hig

h Vo

ltage

6.5”

NOTE: This guide does not provide detailed installation, safety or operational instructions.See the Versillum Light Dimmer User Manual for complete information.

Please scan the QR Code to access the complete User Manual or visit the Cumberland website: http://www.cumberlandpoultry.com

1. Set toggle switch for Zone 1 and Zone 2 to manual mode (Man). The toggle switch light will change from green (Auto) to red (Manual). NOTE: To optimize light performance, the Versillum includes 3 types of waveform curves for lights. They are called (T), (L), and (C) curves. The most commonly used waveform is (T) and is the factory default setting. If the lights are flickering, you may need to change the waveform curve by setting the DIP switches located on the back of the cover plate. Refer to Wiring Diagram for settings.

2. Turn the knob clockwise until the light is at 100%, then slowly turn the knob counterclockwise and make sure the lights dim properly without flickering at any of the percentage points. If the lights do not flicker, go to Step 8.

3. If the lights do not dim properly, try waveform curve (L) by setting the DIP switches. Important: During installation and during first trials with low load of lights, it is important to change the waveform curve if a lot of overcurrent (OVC message and triangle warning symbol) detections occurs. A good setup has to limit the flickering and the current peaks during dimming.

4. Repeat Step 2.

5. If the lights do not dim properly, try waveform curve (C) by setting the DIP switches.

6. Repeat Step 2.

7. Contact technical support for more help if lights still do not dim properly.

8. Set the Min. and Max. Intensity: Minimal Intensity = All lights are ON at their lowest intensity. Maximum Intensity = The lowest voltage where lights are ON at full intensity.

a. Press and hold the Set button (1) for 7 seconds.

b. Make sure the toggle switch (2) is set to manual for the Zone you want to change. NOTE: The knob (3) will not work unless the switch is in the Manual position.

c. Use the knob (3) to increase or decrease the value.

d. Press the Set button (1) to accept the new value or the Scenario button (5) to cancel.

Only properly trained service personnel may perform installation and service procedures. (In other words: electricians, service personnel employed by or active in an organization, business, or service).

All power must be turned off prior to wiring, installing, servicing, setting the bypass switches or the DIP switches.

More than one disconnect is required to de-energize power to the Versillum Light Dimmer.

Make sure to separate high voltage wiring from low voltage (Class 2) control wiring.

Use copper wires only.

CFL and CCFL lamps must be ELV ballast type (electronic only)

1. To adjust light intensity manually, place the switch of the corresponding Zone to the (Man) position and turn the knob.

2. To adjust light intensity automatically, place the switch of the corresponding Zone to the (Auto) position and set the 0-10V output from the master controller.

Refer to the user manual to configure the light type control, the Min. and Max. intensity, the skipped points, to merge the 0-10V inputs on Zone 1, and to merge the knob control.

GSI Electronics Inc.5200 Armand Frappier Saint-Hubert, Qc

Canada J3Z 1G5Phone: 1-877-926-2777

E-mail: [email protected]

Versillum Light DimmerQuick Start Guide

1 - NOTICES

3 - INSTALLATION

WARNING: Read the following text carefully; it contains important information which, if ignored, may cause the controller to operate improperly.

High Voltage. Hazard of electrical shock.

Protective Earth Ground Terminal. Primarily used for protective earth terminals.

2 - SAFETY SYMBOLS

4 - SETUP 5 - BASIC OPERATION

Minimal Intensity

Maximum Intensity

The Versillum Light Dimmer must be mounted in a location that has sufficient air circulation around the box. Minimum clearance is 25” W x 29.5” H to ensure protection against electrical conducted noise.

1. Mount the Versillum on the wall using the minimum clearance and wire it referring to the wiring diagram. Install using 4 lag screws.

1. Man - Indicates manual mode operation2. The (+) indicates that a custom curve is being used

(Min. and Max. have been set)3. White light bulb indicates that the lights are ON.4. Auto - indicates automatic mode operation and

lights are being controlled by another controller5. The (T) indicates that lights are using (T) mode

waveform.6. Black light bulb indicates lights are OFF7. The number indicates the percentage of voltage

being used by lights8. The percentage bar indicates the percentage of

voltage being used or if the light is OFF9. Indicates the Amps being used by the lights

Item Description1 Zone 1 settings display area2 Zone 2 settings display area3 Set button4 Scenario button5 Zone 1 intensity knob6 Zone 1 mode switch7 Zone 2 intensity knob8 Zone 2 mode switch9 Manual mode indicator light

10 Auto mode indicator light

Controls and Display Layout

Display Layout

EN

Page 2: Versillum Light Dimmer - Quick Start Guide€¦ · Si les lumières ne s’atténuent pas correctement, essayez la courbe de forme d’onde (L) en réglant les commutateurs DIP. Important:

L1N/L2L1N/L2 L1 N/L2N/L2L1

External Controller

Dry contact

input45m max.

Power

InOut

OR

See Note 1

0-10V Master Controller Output

0-10V

10m max.

+-

See Note 1

0-10V

10m max.+-See Note 1

0-10V

10m max.+-See Note 1

Zone 2

Zone 1

10m max.

+-

See Note 1See Note 1

BKRD

RDBK

RDRD

BK

BK

BKRD

RDBK

1 2 3 4 5 6 7 8 9 10L ON OFFT OFF ONC ON ONL ON OFFT OFF ONC ON ON

ONON

ZONE 2 WAVEFORM

MERGE MANUAL CONTROLMERGE 0-10V INPUTS ON ZONE 1

DIP SWITCH POSITION

ZONE 1 WAVEFORM

PARAMETERS

Note 1: 1 x shielded twisted pairs, 18 AWG (min), 600V, 90C (min)

Note 2: Versillum Light Dimmer will internally merge it’s two 0-10V inputs to control simultaneously Zone 1 and Zone 2 outputs.

COLOR CODERED RD

BLACK BK

INPUTS :SUPPLY INPUT: • 100-120/220-240Vac -10%\+6%,

50-60Hz,1/2 phase(s) • 0-10V INPUT (Zone 1, 2): 0-10V,

2mA max

OUTPUTS:• DRY CONTACT SCENARIO

IMPULSE: 24Vdc max, 100mA max

POWER OUTPUT (Zone 1, 2): • 100-120/220-240Vac 8.33Amps max• 100-120Vac, 833-1000VA

(incandescent, CFL/CCFL, LED)• 220-240Vac, 1833-2000VA

(incandescent, CFL/CCFL, LED)

Operating Temperature: -5 to 40°C (23 to 104°F)

Safety Ratings

From electrical distribution panelBreaker 1 max: 15Amps in series with a voltage interrupter

ZON

E 1

light

gro

up

8.33

A m

ax From electrical distribution panelBreaker 2 max: 15Amps in series with a voltage interrupter

ZON

E 2

light

gro

up

8.33

A m

ax

The fixture has an earth connection or no earth connection (double square symbol means double insulation)

Symbol Meaning

If the fixture has an earth connection, connect it directly to the electrical distribution panel.

Zone 1 AC inputs also supply the Versillum Light Dimmer controller part

Lamp details: Voltage: 120V,9 watts and 100mAPower Output Amperage available: 8.33A on 100-120V or on 220-240V

Determine how many lamps to use on each Zone output using this formula:

Determine the PF (Power Factor) using this formula:(PF must be higher than 0.5)

Round off the decimal pointto get a total of 83 lamps.

Set the DIP switch #6 to “ON” position (See Note 2)

When there are multiple Versillum Light Dimmers for one 0-10V Master Controller Output, connect Versillum Light Dimmer inputs in daisy chain on Zone 1 (0-10V) inputsVersillum Light Dimmer 4

Versillum Light Dimmer 1 0-10V Master

Controller Output

0-10V

Multiple Versillum Light Dimmers 0-10V inputs from Master Controller with light programs

With one source of 0-10V for two Zones

Set the DIP switch #6 to “ON” position (See Note 2)

Versillum Light Dimmer 0-10V inputs from Master Controller with light programs

Versillum Light Dimmer

Versillum Light Dimmer Versillum Light

Dimmer

With two independant Zone inputs

To activate the Dry Contact Scenario Impulse Output, Press and hold the “Scenario” button for at least 2 seconds.

0-10V Master Controller Outputs

Zone bypass switches can be set to ON position to keep light output at 100% Versillum Light

Dimmer

9 watts120V * 0.1A

= 0.75PF =

8.33A0.1A

= 83.3Numberof Lamps =per Zone Power Factor (PF) = Lamp Power (watts)

Lamp Voltage (V) * Lamp Current (A)

Formula Example

Power Output Amperage (A)Lamp Current (A)

Number of Lamps per Zone =

Formulas

Zone bypass switches have to be set to OFF position to use the Versillum Light Dimer in normal operating mode. Factory default setting is the OFF position.

Versillum Light Dimmer Wiring Diagram

One Versillum Light Dimmer 0-10V input draws 2 mA. Make sure that the 0-10V Master Controller Output can supply multiple Versillum Light Dimmers in parallel.

Versillum Light Dimmer Dry contact output 24Vdc, 100mA max.

EN

Page 3: Versillum Light Dimmer - Quick Start Guide€¦ · Si les lumières ne s’atténuent pas correctement, essayez la courbe de forme d’onde (L) en réglant les commutateurs DIP. Important:

QSG 892-00089 REV03

Haute Tension

Haute Tension

Hau

te Te

nsio

n

Hau

te Te

nsio

n

6.5”

10”

10”

Hau

te Te

nsio

n

Hau

te Te

nsio

n

6.5”

REMARQUE : ce guide ne fournit pas des instructions détaillées relatives à l’installation, la sécurité ou le fonctionnement. Pour obtenir des informations complètes, veuillez vous reporter au manuel de l’utilisateur du gradateur de lumière Versillum.

Pour accéder au manuel de l’utilisateur complet, veuillez scanner le code QR ou consulter le site Web Cumberland : http://www.cumberlandpoultry.com

1. Mettez l’interrupteur à basculement pour la zone 1 et la zone 2 en mode manuel (Man). Le voyant de l’interrupteur à basculement passe du vert (Auto) au rouge (Manuel). REMARQUE: Pour optimiser la performance de l’éclairage, le Versillum comprend 3 types de courbes de forme d’onde pour l’éclairage. On les appelle des courbes (T), (L) et (C). La forme d’onde la plus couramment utilisée est (T), qui correspond au réglage usine par défaut. Si les lumières clignotent, vous devrez peut-être modifier la courbe de forme d’onde en réglant les commutateurs DIP situés au dos du couvercle de protection. Reportez-vous à la section Schéma de câblage pour les réglages.

2. Tournez le bouton dans le sens horaire jusqu’à ce que la lumière soit à 100 %, puis tournez lentement le bouton dans le sens antihoraire et assurez-vous que les lumières s’atténuent correctement sans clignoter à aucun des points de pourcentage. Si les lumières ne clignotent pas, passez à l’étape 8

3. Si les lumières ne s’atténuent pas correctement, essayez la courbe de forme d’onde (L) en réglant les commutateurs DIP. Important: Lors de l’installation et lors des premiers essais avec une faible charge de lumières, il est important de changer la courbe de forme d’onde si de nombreuses détections de surintensité (messages OVC et symbole d’avertissement triangle) se produisent. Une bonne configuration doit limiter le scintillement et les pics de courant lors de la variation.

4. Répétez l’étape 2. 5. Si les lumières continuent de scintiller, changez

la courbe du signal en (C) en réglant les commutateurs DIP.

6. Répétez l’étape 2. 7. Contactez le support technique pour obtenir

davantage d’aide si les lumières ne s’atténuent toujours pas correctement.

8. Réglez l’intensité minimale et maximale: Intensité minimale = toutes les lumières sont allumées à leur plus faible intensité. Intensité maximale = tension la plus basse à laquelle les lumières sont allumées à pleine intensité.

a. Appuyez sur le bouton Réglage (1) et maintenez-le enfoncé pendant 7 secondes.

b. Assurez-vous que l’interrupteur à basculement (2) est réglé sur la position manuelle pour la zone que vous voulez changer. REMARQUE: le bouton (3) ne fonctionnera pas si l’interrupteur n’est pas en position manuelle.

c. Utilisez le bouton (3) pour augmenter ou diminuer la valeur.

d. Appuyez sur le bouton Réglage (1) pour accepter la nouvelle valeur ou sur le bouton Scénario (5) pour annuler.

Seul le personnel de service dûment formé peut procéder aux procédures d’entretien et d’installation. (En d’autres termes : les électriciens, le personnel de service employé ou actif dans une organisation, une entreprise ou un service.)

Toute alimentation doit être coupée avant le câblage, l’installation, l’entretien, le réglage des interrupteurs de contournement ou des commutateurs DIP.

Plusieurs déconnexions sont nécessaires pour mettre hors tension le gradateur de lumière Versillum.

Veillez à séparer le câblage haute tension du câblage de commande basse tension (classe 2).

Utilisez uniquement des fils de cuivre.

Les lampes CFL et CCFL doivent être des ballasts de type ELV (électronique seulement)

1. Pour régler manuellement l’intensité lumineuse, placez l’interrupteur de la zone correspondante sur la position (Man) et tournez le bouton.

2. Pour régler automatiquement l’intensité lumineuse, placez l’interrupteur de la zone correspondante sur la position (Auto) et réglez la sortie 0-10 V du contrôleur maître.

Reportez-vous au manuel d’utilisation pour configurer le contrôle du type de lumière, l’intensité minimale et maximale, les points de contournement, les entrées 0-10 V fusionnée sur la zone 1, et la commande manuelle combinée.

GSI Electronics Inc.5200 Armand Frappier Saint-Hubert, Qc

Canada J3Z 1G5Phone: 1-877-926-2777

E-mail: [email protected]

Gradateur de lumière Versillum Guide de démarrage rapide

1 - Avertissements

3 - Installation

AVERTISSEMENT: lisez attentivement le texte suivant ; il contient des informations importantes. Si vous les ignorez, cela peut entraîner le dérèglement du contrôleur.

Haute tension. Risque de choc électrique.

Borne de mise à la terre de protection. Principalement utilisé pour les bornes de terre de protection.

2 - Symboles de sécurité

4 - Configuration 5 - Opération de base

Intensité minimale

Intensité maximale

Le gradateur de lumière Versillum doit être monté dans un endroit où l’air circule suffisamment autour du boîtier. Le dégagement minimum est de L 25 po x H 29,5 po pour assurer la protection contre le bruit électrique.

1. Montez le Versillum sur le mur en respectant le dégagement minimum et effectuez le câblage en vous référant au schéma de câblage. Installez à l’aide de 4 vis à bois.

1. Man - indique que le mode est “en manuel”2. Le signe (+) indique qu’une courbe personnalisée

est utilisée (l’intensité minimale et maximale a été définie)

3. L’ampoule blanche indique que les lumières sont allumées.

4. Auto - indique un fonctionnement en mode automatique et le fait que les lumières sont contrôlées par un autre contrôleur.

5. Le (T) indique que les lumières utilisent la forme d’onde du mode T.

6. L’ampoule noire indique que les lumières sont éteintes.

7. Le chiffre indique le pourcentage de tension utilisé par les lumières.

8. La barre de pourcentage indique le pourcentage de tension utilisé ou si la lumière est éteinte

9. Indique les ampères utilisés par les lumières.

# Description1 Zone d’affichage des réglages de la zone 12 Zone d’affichage des réglages de la zone 23 Bouton Réglage4 Bouton Scénario5 Bouton d’intensité de la zone 16 Commutateur de mode de la zone 17 Bouton d’intensité de la zone 28 Commutateur de mode de la zone 29 Voyants lumineux du mode Manuel

10 Voyants lumineux du mode Auto

Disposition des commandes et de l’affichage

Disposition de l’affichage LED

FR

Page 4: Versillum Light Dimmer - Quick Start Guide€¦ · Si les lumières ne s’atténuent pas correctement, essayez la courbe de forme d’onde (L) en réglant les commutateurs DIP. Important:

FR

Page 5: Versillum Light Dimmer - Quick Start Guide€¦ · Si les lumières ne s’atténuent pas correctement, essayez la courbe de forme d’onde (L) en réglant les commutateurs DIP. Important:

QSG 892-00089 REV03

Alto Voltaje

Alto Voltaje

Alto

Vol

taje

Alto

Vol

taje

6.5”

10”

10”

Alto

Vol

taje

Alto

Vol

taje

6.5”

Nota: Esta guía no proporciona instrucciones detalladas de instalación, seguridad ni operación. Consulte el Manual del usuario del regulador de intensidad Versillum para obtener toda la información necesaria.

Escanee el código QR para acceder al Manual del usuario completo o visite el sitio web de Cumberland: http://www.cumberlandpoultry.com

1. Ajuste el interruptor basculante para la Zona 1 y la Zona 2 en el modo manual (Man). La luz del interruptor basculante cambiará de verde (automático) a rojo (manual). NOTA: Para optimizar el rendimiento de la luz, el Versillum incluye 3 tipos de curvas de forma de onda para las luces. Se denominan curvas (T), (L) y (C). La forma de onda usada con más frecuencia es (T) y es la configuración predeterminada de fábrica. Si las luces parpadean, es posible que necesite cambiar la curva de forma de onda mediante el ajuste de los interruptores DIP situados en la parte posterior de la placa de recubrimiento. Consulte el diagrama de cableado para conocer los ajustes.

2. Gire la perilla hacia la derecha hasta que la luz esté al 100 % y, a continuación, gire lentamente la perilla hacia la izquierda y asegúrese de que las luces se regulen de forma correcta, sin parpadeos, en todos los puntos porcentuales. Si las luces no parpadean, vaya al Paso 8.

3. Si las luces no se regulan correctamente, pruebe la curva de forma de onda (L) mediante el ajuste de los interruptores DIP. Importante: Durante la instalación y durante las primeras pruebas con poca carga de luces, es importante cambiar la curva de forma de onda si se producen muchas detecciones de sobrecorriente (mensajes OVC y símbolo de advertencia de triángulo). Una buena configuración tiene que limitar el parpadeo y los picos actuales durante la atenuación.

4. Repita el Paso 2.

5. Si las luces no se regulan correctamente, pruebe la curva de forma de onda (C) mediante el ajuste de los interruptores DIP.

6. Repita el Paso 2.

7. Comuníquese con soporte técnico para obtener asistencia si las luces siguen sin regularse correctamente.

8. Ajuste los valores mínimo y máximo de intensidad: Intensidad mínima = Todas las luces están encendidas con la menor intensidad. Intensidad máxima = El voltaje más bajo en el que las luces están ENCENDIDAS con la máxima intensidad.

a. Presione y mantenga presionado el botón Ajuste (1) durante 7 segundos.

b. Asegúrese de que el interruptor basculante (2) esté establecido en manual para la zona que desea cambiar. NOTA: La perilla (3) no funcionará a menos que el interruptor esté en la posición manual.

c. Utilice la perilla (3) para aumentar o disminuir el valor.

d. Presione el botón Ajuste (1) para aceptar el nuevo valor o el botón “Caso especial” (5) para cancelar.

Solo el personal de servicio correctamente capacitado puede realizar los procedimientos de instalación y servicio. (En otras palabras, electricistas, personal de servicio empleado o activo en una organización, empresa o servicio).

Se debe apagar toda la alimentación antes de realizar el cableado, la instalación, las tareas de mantenimiento o la configuración de los interruptores de derivación o los interruptores DIP.

Se requiere más de una desconexión para desenergizar el suministro eléctrico al regulador de intensidad Versillum.

Asegúrese de separar el cableado de alto voltaje del cableado de control de bajo voltaje (Clase 2).

Utilice solo cables de cobre.

Las lámparas CFL y CCFL deben tener balastros de tipo ELV (electrónicos únicamente)

1. Para ajustar la intensidad de la luz manualmente, coloque el interruptor de la zona correspondiente en la posición (Man) y gire la perilla.

2. Para ajustar la intensidad de la luz automáticamente, coloque el interruptor de la zona correspondiente en la posición (Auto) y ajuste la salida de 0 a 10 V desde el controlador principal.

Consulte el Manual del usuario para configurar el control del tipo de luz, los valores mínimo y máximo de intensidad, los puntos a omitir, la combinación de las entradas 0-10V en la Zona 1 y la combinación de las perillas.

GSI Electronics Inc.5200 Armand Frappier Saint-Hubert, Qc

Canada J3Z 1G5Phone: 1-877-926-2777

E-mail: [email protected]

Regulador de intensidad Versillum - Guía de inicio rápido

1 - Avisos

3 - Instalación

ADVERTENCIA: Lea detenidamente el texto siguiente, ya que contiene información importante que, si se ignora, puede provocar que el controlador funcione de forma incorrecta.

Alta tensión. Peligro de descarga eléctrica.

Terminal de conexión a tierra para protección. Se utiliza principalmente para proteger los terminales de conexión a tierra.

2 - Símbolos de seguridad

4 - Configuración 5 - Operación básica

Intensidad mínima

Intensidad máxima

El regulador de intensidad Versillum debe montarse en un lugar que tenga suficiente circulación de aire alrededor de la caja. La holgura mínima es de 25” de ancho x 29,5” de alto para garantizar la protección contra el ruido propagado mediante la electricidad.

1. Monte el Versillum en la pared con la holgura mínima y conéctelo según el diagrama de cableado. Para la instalación, utilice cuatro tornillos tirafondos.

1. Man - Indica el funcionamiento en modo manual2. El signo (+) indica que se está utilizando una curva

personalizada (el valor mínimo y el máximo ya han sido establecidos).

3. La bombilla de luz blanca indica que las luces están ENCENDIDAS.

4. Auto - Indica el funcionamiento en modo automático (el controlador principal controla las luces a través de la entrada 0-10V)

5. La (T) indica que las luces están utilizando la forma de onda del modo T.

6. La bombilla de luz negra indica que las luces están APAGADAS.

7. El número indica el porcentaje de voltaje que utilizan las luces.

8. La barra de porcentaje indica el porcentaje de voltaje que se está utilizando o si la luz está APAGADA.

9. Indica los amperios que utilizan las luces.

# Descripción1 Área de visualización de los ajustes de la Zona 1

2 Área de visualización de los ajustes de la Zona 2

3 Botón Ajustes4 Botón Caso especial5 Perilla de intensidad de la Zona 16 Interruptor de modo de la Zona 17 Perilla de intensidad de la Zona 28 Interruptor de modo de la Zona 29 Luz indicadora del modo manual

10 Luz indicadora del modo automático

Disposición de los controles y la visualización

Diseño de visualización LED

ES