VERSION DESCRIPTION DOCUMENT
Last modification: 2015-09-08
Responsible: Stéphane PÉNEAU (Inspect 3D) Software version: V.5.5.0.0 (patch 1…6)
Date of print 2015/09/28 22 page(s)
VDD_INCA3D_English_2015-09-28_V_5_5_0_7.doc Page 1 of 22 Form I3D-VDD001
Release Date: 2015-03-13
General Advantages:
Pantec Eagle Pro TCP-IP driver and Pantec SMARTPAD management Renishaw REVO powered by INCA3D Solidworks, Parasolid, JT and Inventor CAD files importation
Extensions:
CAD importation o Abilty to import Solidworks, Parasolid, JT and Inventor CAD files
New Driver o PROFITECH ProCount 100 o MR12: Ability to connect 2 counters on 1 computer
Tool manager – Tool builder o Add Tool preview during tool creation o Preview window can also be displayed on the bottom (see menu )
VDD_INCA3D_English_2015-09-28_V_5_5_0_7.doc Page 2 of 22 Form I3D-VDD001
Revo head management o Ability to manage Renishaw REVO head with UCCServer o Ability to scan and probe in 5 axis
o Several strategies available for head position, according to inner or outer feature position, and type of entities
KREON Laser o In Configuration ability to set 3D offset between autojoint and laser field center o Ability to enter Laser center position for AB angle when calibration failed o Ability to set KREON video setting in operation sequence (new script action available)
o Ability to choose also video setting during calibration
VDD_INCA3D_English_2015-09-28_V_5_5_0_7.doc Page 3 of 22 Form I3D-VDD001
Pantec Eagle Driver o TCP-IP Driver o Smart Pad management o Calibration path improvement o SP25 : Ability to re-calibrate an already scanned orientation only by probing in trigger
mode and using the latest SP25 calibration matrix o
Starting new execution o When starting a new execution from the top of the operation sequence, Inca3D ask user
to choose several options: “Reset measure and continue” : means that INCA will erase all the previous
results and continue to work in the same measurement file “Create measure#2 and continue: means that the measurement 1 will be saved
as it is and a new measurement file (#2) will be created for the new part “keep and continue”: that was the way Inca3D worked before, we keep the
result of the previous part but they will be replaced one by one during the execution
“stop” will stop the execution
o This window can be disabled in the operation sequence execution parameter (yellow+)
Rotary table o Ability to change rotary table speed o Ability to align 0° position with machine axis
Revo o Ability to set tilt angle constant regarding entity normal vector (available in parallel line
and perpendicular line strategy) o Scanning strategy
ScanXYZ : available only when RSP3 in mounted on Revo ScanXYZAB : available only when RSP2 in mounted on Revo
Symmetrical operation sequence o Abilty to keep view from the GPS with the corresponding mirrored entities, manual
rearranging maybe necessary
In geometrical alignment o Ability to select filter for X Y and Z together by CTRL+ Left mouse click. Also available to
select referenced entity o Red target is now separate to select X, Y and Z in several CAD location
VDD_INCA3D_English_2015-09-28_V_5_5_0_7.doc Page 4 of 22 Form I3D-VDD001
Ability to fill header fields (Project name” and “Part Name”) with the operation sequence name
Measpath Editor: o When Always recalculate is checked, Measuring path is displayed greyed in the
measuring path editor, because it is not possible to change the measpath. The modification are not taken into account because the measpath is always recalculated.
Operation sequence Editor: o In execution : Ability to set first and last line to execute regarding to editor selection
o When an action is open in parameter window ability to open previous action
(CTRL+SHIFT+UP) or next action (CTRL+SHIFT+DOWN)
New Action o Circle : Tangent to 2 Circles with a given Radius
VDD_INCA3D_English_2015-09-28_V_5_5_0_7.doc Page 5 of 22 Form I3D-VDD001
o Line : Tangent to a Circle through a Point
Measure Window o New Graphical user interface
o Abilty to validate current or several measurement files (using multi selection using CTRL
+ Click ) o Same with Delete, Reset or virtual validation o By default, All active fields from the header are displayed, they can be hidden by pop-
up menu
Calibration window o Ability to activate/deactivate some probe (with F6 or pop-up menu)
VDD_INCA3D_English_2015-09-28_V_5_5_0_7.doc Page 6 of 22 Form I3D-VDD001
Plane Measuring path o In strategy by circle ability to probe several circles.
Graphical programming o Ability to check measuring path validity regarding CMM limits o User can select a list of entities to check if the path stay in the machine limits to avoid
error message during execution
o o Then Inca3D display in red the paths that go out of the CMM limit boxex (in blue) o
VDD_INCA3D_English_2015-09-28_V_5_5_0_7.doc Page 7 of 22 Form I3D-VDD001
Milling o Management of MORA RSM1 Milling head o Ability to adjust milling position during milling process. Adjust on X, Y, Z
o Ability to speed up or down the milling feed rate
o
Inca 3D shared directory for CAA softkomp.ini and virtual machine vm.ini o To avoid trouble with windows virtual store directory both softkomp.ini and vm.ini files
are now located in “Inca3d\machine” o This new location also allows using 2 different CAA files when working in multi machine
mode
Usable Operating Systems: Windows™ Eight Pro (64 or 32 bits without aero); Windows™ Seven Pro (64 or 32 bits
without aero); Windows™ Vista Pro (64 or 32 bits without aero), Windows™ XP Pro (32 bits),
Compatibility of the hardware device, Counter Card, Link to DCC must be checked separately with the hardware provider
INCA3D installation and License Key Installation must be performed with Windows™ administrator right.
Multiplex Configuration:
Working directories /CAD and /OperationSequence should be same shared directories on all PC’s.
Dongle driver:
Download at http://www.inspect-3d.com/english/software/download.htm - For Windows Vista, Seven, XP 1- Install first HASP HL Driver V5.22: haspusersetup.exe (V5.22) 2- Then install HASP4 Device Drivers V 5.22: hdd32.exe (HASP4 V 5.22)
VDD_INCA3D_English_2015-09-28_V_5_5_0_7.doc Page 8 of 22 Form I3D-VDD001
Remarks
Some of the functions and improvements described in this document may not be available for your INCA3D license depending on Package and options. Contact us for further details
Documentation updates: 2013-07-15 English Help Version E.1.21 2013-07-15 German Help Version G.1.9 2013-07-15 French Help Version F.1.12 2013-07-15 Chinese Help Version C1.0
Valid Maintenance Date needed: 2015-03-15
Wishes Done: R5414:”In catalog of tools, add the M2 and M3 ITP stylus. New filter ITP like Renishaw, Tesastar”
DONE R5210:”Ability to change Radius/Diameter in measpath wizard nominal circle”UNIPPS #5428
DONE R5499:”I3D.opt / Debug parameters: Handle relative directory for debug file name” DONE R5261:”Section/Grid/Extract geom elt : if there is existing elements in the Selected elements
propertie window, it is not possible to delete them before sending calculated points. Should add a question to remove them or not.” DONE
R5522:”Start automatic calibration in one of the machine axis when it's possible” DONE R5523:”Stylus cylinder calibration: calibration measuring path does not used the full sphere to
calibrate when possible (only used 180°)” DONE R5524:”Pantec Eagle + Calibration : to make like a circular move, a security distance offset can
be define in Inca.ini. Distance is substract to the Maximum security distance” DONE R5529:”By default when you move a window it should never dock (f.i Select elements properties"
window). You should press "Alt" key to have the possibility to dock it.” DONE R5530:”When an action is opened in teach and mesure mode we should be able to open the
previous or next operation by pressing (Ctrl + Shift + Up) or (Ctrl + Shift + Down) keys. It would be much faster to open consecutive existing operations.” DONE
R5517:”Conversion of Cad files from Inventor and JT formats” DONE R5594:”In InfoEvent, if the image or sound is not found, search it in the directory of the operation
sequence.” DONE R5606:”Rename head ZAK 6 to RSM1” DONE
Fixed Bugs: R5385:”In the "section labels parameter" window it is not possible to save default parameters, we
need to enter each time the link line width.” FIXED R5413:”Pantec.Cmm.Driver for Builder XE: New driver management. PantecLink.dll does not
communicate directly to the Pantec.Cmm.Driver but now by an intermediate dll: PantecCmmDriver.dll” FIXED
R5426:”Reloading user tolerance from file is not working properly. Have to close Inca to get it really reloaded” FIXED
R5487:”New management for text file” FIXED R5492:”Execute all batch file created and executed by Inca3D with administrator right” FIXED R5446:”Create a plane and a section in editor, then send section point from graphical
programming to GUI -> Error message.” FIXED R4774:”On manual CMM, confirmation of reprobing between each point in Complex alignment
should not be checked by default” FIXED R5046:”Reprobing surface alignment window does not manage dual screen.” FIXED R5392:”Keyboard variable : Focus is not set to the edit, so user must click with mouse before
keyboarding” FIXED R5494:”In the Report Configuration window, if the field "File" in "Export file name" is blanked,
each time we change the Report Kind (f.i Export in Text file to Export in MS Excel file) the export file name window is opened … should not.” FIXED
R5512:”If in the configuration module, the simplification file name is empty, there is an error message displayed at the Inca3D start.” FIXED
R4071:”Ops editor: select a measpath element in the treeview + CTRL-A, it select only all the measpath element instead of selecting all the action” FIXED
VDD_INCA3D_English_2015-09-28_V_5_5_0_7.doc Page 9 of 22 Form I3D-VDD001
R5533:”In High Level, after a Jump operation the result window is always cleaned. The last displayed result should not be removed.” FIXED
R4562:”MIH head with PAA1: it seems that PAA is not well displayed” FIXED R5456:”Windows positions : Dual screen #12, #13 ... positions are not really usable for large
screens. Could also add a menu to reverse the 2 screens.” FIXED R5547:”Load OPS from another OPS, then switch to teach and execute the action. After end of
probing the action never perform the calculation. Button Stop is still displayed” FIXED R5555:”Plane construct by points, the form deviation is not displayed in the tab sheet result
window” FIXED R5557:”In High Level mode, in execution, when I click on an entity the display result mode does
not switch to manual” FIXED R5559:”Report in TXT: Add an empty line between entities does not work anymore” FIXED R5563:”When executing "load tool file action" File existence is not tested, no error message,
execution continue with current loaded tool file” FIXED R5490:”MH8 + Manual CMM: when select several probes in toolmanager treeview not possible to
calibrate all probes in one sequence” FIXED R5595:”After alignment recalculation and selection of the multi-solution (move or not move the
points) all actions become unvalid (with a red question mark ?)” FIXED R5596:”DMIS Statement DECL is followed by a "," instead of a "/"” FIXED R5604:”Load multiple OPS with bar code reader.
(1) The default icon is not tranparent (magenta background). (2) The order of ops in the list changes between measures. (3) If the focus is on the list and I validate with the bar code reader, the bar code value is not taken into account” FIXED
R4282:”By default the tab sheet "Operation sequence" is activated when I execute the header action.” FIXED
Modifications & Bug fixes (V5501 – 2015-04-30):
New MORA milling head RSM1 o Abilty to display in field of the measure header in measure window
Ability to extract rectangle with round corner
Display IP address of the local computer in Duplex configuration
Virtual part alignment: o Ability to set the part location on the plate
VDD_INCA3D_English_2015-09-28_V_5_5_0_7.doc Page 10 of 22 Form I3D-VDD001
Leapfrog o Ability to use more entities
Guidance window
o Add ability to clear the list when closing the window o Improve speed o Ability to use the guidance window during execution
o Pantec Eagle probing head and scanning probe management
o
VDD_INCA3D_English_2015-09-28_V_5_5_0_7.doc Page 11 of 22 Form I3D-VDD001
Wishes Done: R5653:”Complex alignment and surface alignment Multiple creation mode : When drag and drop
a list of measured operations in a real combobox, should select Real in the the multiple creation window.” FIXED
R5654:”Complex alignment.Add the possibility to hide to tolerances in the list to ensure that complete nominal and actual references are fully visible.” FIXED
R5451:”Collision avoidance window should be resized according to the number of collisions” FIXED
Fixed Bugs: R5603:”Statistic label : if one measurement file is missing (or is not valid) stat graph label is
empty. We should display the existing measure.” FIXED R5580:”When display result with deviation position code. Statistic label are not displayed
anymore” FIXED R5609:”When the Measuring path editor is opened, in the parameter window the Execute button
should be grayed.” FIXED R5585:”Measured cloud of point: all points displayed with Dev vector. After changing search dist
or search angle, some points cannot be calculated. But the Dev vect is still displayed for these points.” FIXED
R5614:”Cannot calibrate standard probe (Knuckel, PH6, …) from "Calibrate all tool" action” FIXED
R5607:”Formula in header (123+Meas.num) does not appear correctly in Measure management window” FIXED
R5636:”ToolBuilder : The preview of the selected element in the list of compatible elements should be visible only when the user select one element.” FIXED
R5640:”Complex alignment : When I re-execute a complex alignemnt, the confirmation window displayed between each point lock the graphic view so I cannot zoom, move the view to see where is the target point.” FIXED
R5641:”Dual screen positions 12 & 13 display too large editor and counter (on both screens) and if the task bar is in permanent mode Inca3D does not reduce its size.” FIXED
R5637:”In the preview of the ToolBuilder. - The PH9 is displayed with triangles and some are missing. - "Generic disk" preview is not fine, the disk appears very small in the bottom.” FIXED
R5620:”Symmetry of section CAD file (_sct) created by Inca is not working (bgf to bgf)” FIXED R5655:”When Inca3D is run without administrator rights, Inca3D has not the right to write in
HKEY_LOCAL_MACHINE. FIXED R5657:”When using 2 screens and than using only one, the graphical programming dialogs are
still displayed on the disconnected screen.” FIXED R5645:”If put a "&" character in an operation reference then in the editor it is replaced by "_"
character. Should stay as "&" character.” FIXED R5660:”If I store an operation Shape profile or Curve profile and reopen it, if I switch between
"List" and "Entity" and switch back to "List" then the references selected in the list are duplicated.” FIXED
Modifications & Bug fixes (V5502 – 2015-05-18):
R5658:”Global modification of coord. Syst. In Circles Probed point are moved but not gage points” FIXED
R5664:”Intersection Line - Cylinder gives only one solution instead of 2.” FIXED R5665:”Faro control database importation gives error message since V5.5.0.0” FIXED R5661:”Extract rectangle does not always give result on solidworks part”FIXED R5667:”After execute a circle scanned, when create a Machine Param action all parameter are
checked even they are equal to default” FIXED R5668:”I++: When define a start probe in tool builder, it's not possible to assign the tip for each
tool. It always used the first tip available”FIXED R5669:”Padlocks image are not anymore visibles in Surface points, edge points and section
points.” FIXED R5673:”Excel report, if Full Excel Report not checked then all cells are filled with "TRUE"
character.” FIXED
VDD_INCA3D_English_2015-09-28_V_5_5_0_7.doc Page 12 of 22 Form I3D-VDD001
Modifications & Bug fixes (V5503 – 2015-07-03):
Measuring path editor o Ability to open measuring path editor with clicked point active (double click)
o
o At the same time the measuring path is displayed and user can see selected element
highlighted (light blue) o Probed point can be selected in the graphic (right click) and activated in the measuring
path editor (left click)
o For large part the light blue circle allow to see where is the selected point even if the ball
diameter is very small compare to the part o Probed point can be selected in the graphic (right click) and activated in the measuring
path editor (left click)
VDD_INCA3D_English_2015-09-28_V_5_5_0_7.doc Page 13 of 22 Form I3D-VDD001
New arranging method to create a view with all entities “out of tolerance”
New action optimize probe calibration o Ability to use result of a measured entity to optimize probe
diameter and also probe offset o In the example below, user optimized the probe diameter regarding
the result of a measured circle in a gage ring o
o
VDD_INCA3D_English_2015-09-28_V_5_5_0_7.doc Page 14 of 22 Form I3D-VDD001
FD&T management in Catia V5 files
o
Wishes Done: R5696:”Possibility to define the number of intermediate circle used when display Cylinder/Cone”
DONE R5697:”Improve the rendering by changing the background color when use transparency (probe
and CMM)” DONE R5687:”Put the shortcuts Ctrl R and Ctrl E in the hints in the selection window because some
customers do not know those fundamentals shortcuts.” DONE R5710:”Out of tolerance sound is only used in execution mode, it should be also used in Teach
and Learn. Sound should be done also if no confirmation is requested.” DONE R5703:”Multi machine : when customer switch from single machine to multi-machines. All files
from /Machine and /Tool directories must be copied in /Machine1 /Tool1.” DONE R5719:”3D Service CAA” DONE R5720:”In tools manager, do not display any more importation date in case of UCC” DONE R5721:”Eagle driver: Instead of only display of dll's driver version (About CMM Drivers in popup of
the counter window) We calculate the corresponding Eagle driver installed. Information is also available in Machine.info under Inca3D\Machine folder” DONE
R5702:”Multi machine : hotlinemessenger only the active config is saved” DONE R5729:”In duplex mode all algnment actions are creating a synchronization between the 2
machines and should not expect for alignement with surface points and complex alignment” DONE
R5734:”Pantec Eagle + SP25: Used by default command scan end is plane instead of command scan end is sphere to avoid trouble when the end sphere center is not located well or end sphere diameter to small” DONE
R5735:”Instead of display Home position error message then Home confirmation dialog, display directly the Home confirmation dialog” DONE
R5736:”Pantec + SP25: When stop execution of a scanned action, probe move out the part and after few second we received a unexpected probe point DONE
R5755:”New actions : Roundslot projected in a plane and Rectangle projected in a plane” DONE R5762:”DMIS importation : New option "Import minimum commands" in order to reduce the
operation sequence size” DONE R5737:”SCR200: Add possibility to not move the probe across the face of the hall sensor during
change stylus cycle” By default we do not move to the face of hall sensor DONE
Fixed Bugs: R5708:”If I open two consecutives actions of same kind with FD&T tolerances, in the second
action the combobox of FD&T tolerances is not filled. If reopen it it is filled.” FIXED R5698:”With EDGE the Temporary nominal element displayed in RED is only a Pt Vector (edge
vector is missing)” FIXED R5712:”The simulator cannot make manual probed point in axis Y” FIXED R5671:”With some cylindrical surfaces you cannot click surface point, Inca3D makes only edge
point event if the mouse cursor is in the middle of the surface. You must click surface points on the other side of the surface.”FIXED
R5713:”In tool preview, still have the head oriented along Z axis” FIXED R5704:”Multi machine : CAA doesnot take active machine into account” FIXED R5716:”I++ Server: Sometimes call I++ Command SetProp(Tool.GoToPar.Speed.Act(…)) crash
I++DME communication with host” FIXED R5706:”When selecting SCR200 in the config by default the tool builder is set with TP20 and a
generic extension 203mm???” FIXED
VDD_INCA3D_English_2015-09-28_V_5_5_0_7.doc Page 15 of 22 Form I3D-VDD001
R5663:”creating a section with an existing *_sct.bgf. You cannot click on next and then INCA crash (has stopped working)” FIXED
R5674:”Actions with large parameters window like Scan, Complex Ali … should not display the result windows on the right split.” FIXED
R5739:”Accelerate in the List o Cad element window, the display when select lot of elements (like the node 'surface') for big Cad file” FIXED
R5743:”Import HLM from V4508 for example. If Compensation is enabled Inca3D doesnot activate MORA CAA” FIXED
R5754:”Duplex machine : When I create a list of actions by clicking elements in the graphic and I cancel the creation or I click on cancel when the collision avoidance dialog is displayed then the second Inca3D remains locked and the only solution is to close” FIXED
R5756:”Grid result label of rectangle and roundslot display a form deviation field” FIXED R5759:”Export result to QS stat provides a dfg file not similar to previous version.”Pb with
Unicode encoding FIXED R5747:”Report in one time light one time dark (light V4508 dark V5502)” FIXED R4882:”Pb in graphic report, the lighting is different between screen and preview.” FIXED R5760:”In the scan2D operation, when using SP25, the field "Probe compensation" is misplaced.”
FIXED R5677:”Cannot convert the inca-part,sldprt since new libs”FIXED R5742:”Point order in SCAN2D with SP25 does not follow the curve progression. That may
generate wrong probe compensation value.” FIXED R5758:”Error in scanned circle: circle may be outer instead of inner” FIXED R5763:”Global probe management regarding probe included in the ops is not send to 2nd
computer in duplex” FIXED R5764:”Ability to select the "DMO receiver" in the exportation of the measuring results to DMO
(ex: Quirl)” FIXED R5765:”DMO output : Keep the original name of the tolerance when the ops has been created
thru a DMIS importation” FIXED R5766:”In Label page editor, add a new filter to select only out of tolerance entities.” FIXED R5767:”New action "Optimize probe data"” FIXED R5769:”Global validation of meas was not performed properly in Nplex mode” FIXED R5771:”Duplex : Add in Inca3D the possibility to see the list of actions not ready” FIXED R5772:”Inca3D caption in the task bar does not contain any more the operation sequence name
and measure number” FIXED R5773:”Milling execution, some panels in the tool bar are displayed with gray color instead of
gradient color” FIXED R5776:”In Hotline Messenger module it takes time to store date and size of each file contained by
Inca3D\bin directory. Add a check box to do this on request but not by default.”FIXED
Modifications & Bug fixes (V5504 – 2015-07-17):
Selection of measured entities improvements o Improved selection to select only entities from the operation sequence but not from CAD o Switch automatically from one reference to the other when parameters contain several
referenced entities (like a distance point to point) o When selecting a measured action: a window displays choice between nominal and
actual
Move Joystick in PCS o This feature is available in counter window (for
Mora, Pantec, SB-elektonik and Deva controller) o Management is improved to set up/down move on
the PCS axis that is closest to the CMM Z-axis
Renaming in the editor (F2 or mouse right click menu) o Ability to copy an existing action reference to avoid
typing long string and special characters already available
VDD_INCA3D_English_2015-09-28_V_5_5_0_7.doc Page 16 of 22 Form I3D-VDD001
Wishes Done: R5777:”Display an arrow in the section view on the selected point when the section is created
with a measured curve” DONE R5691:”Copy Paste Special. By default be in circle selection and display the rotation/symmetry
center in the graphic (red point).” DONE R5778:”Action by reference. If click in the graphic, should not select surfaces but operation
sequence entities instead.” DONE R5779:”Distance between measured Points / Lines / Planes. Selection of the operation in the
graphic view (width green target) doest not work.” DONE R5699:”Move in PCS : we must find a way to keep as much as possible the joystick Z (stick
rotation) in the direction of Up /down on the machine otherwise it is alsmost impossible to use” DONE
R5780:”Button for Joystick CS, in counter, does no longer selection of the current coordinate system set to Joystick” DONE
Fixed Bugs: R5781:”When reopen an alignment Plane-Line-Point with the windows position #1, sometime the
plane and line axes are hidden, I must resize the window to see them.” FIXED R5782:”Cannot select points from cloud with selection by fence or lasso when view orientation is
in Plane Coord Syst” FIXED R5783:”Measured edge point result window is not perfectly refreshed.” FIXED R5675:”If I put the Pantec Joystick in PCS mode I must reactivate it each time I open a new
action because it switches back in MCS.” FIXED R5785:”If in the Flatness operation I select a measured circle (by drag n drop or green target) I
have a keyword multiple choice window where I have a single solution : MyCircle.Actual. Should be selected directly.” FIXED
R5761:” I get an error message when trying to extract a recangle x452 y-722 z666 in CAD file” FIXED
R4103:”On their CAD file Tube cannot extract circles” FIXED R5788:”Define point on a grid : If I keyboard a character instead of a value in Start point or
direction vectors there is a crash that can lead to close Inca3D.” FIXED R5789:”Meas path editor. When I insert a gage point or a probed point at the end of the
measuring path I cannot modify the coordinates because save button is grayed.” FIXED R5786:”ASC importation : Plane and line are always imported as simple entitiies even if create
mesured entities is checked” FIXED R5792:”Global modification of measuring path for cylinders, planes & lines is not working properly
(due to the recalculation of the nominal point position regarding to the real position).” FIXED
R5793:”Machine driver SB 3 Counter: Not possible to take the home position” FIXED R5794:”In all actions with more than one red target to select entities in the graphic (like
intersection constructions, geometric alignment …), if I active a green target, should active automatically the next one when the selection is done.” FIXED
R5795:”Change the change probe actions angles with a large amount of actions using this change probe action --> Crash (since V500X)” FIXED
R5809:”Curve displayed in section view. The name of the CAD file is not saved relative to the operation sequence directory set in the configuration” FIXED
R5811:”Group creation with menu "Grouping" or keys Ctrl+G. Should NOT change insert cursor position because it is confusing.” FIXED
R5812:”Cannot import points and curves from Catia v5 files since V5500” FIXED
VDD_INCA3D_English_2015-09-28_V_5_5_0_7.doc Page 17 of 22 Form I3D-VDD001
Modifications & Bug fixes (V5505 – 2015-08-25):
Ability to display XYZ coordinate of the clicked point in real time during selection o Can be deactivate in the view parameters
Fixed Bugs: R5790:”Roundslot : 11798_40_006_01.vda possible to extra the rounslot in 1 edge in GUI but in
CAD construction default extraction give a wrong very small rectangle (L=0.315;W=0.006 on the border of the rounslot)” FIXED
R5815:”Cannot make a symmetry Y on the Catia file. Error when load the bgf in Inca3D”#6755 FIXED
R5816:”Integration of Entity IGES 402 form 1 and form 7. Some files contain this kind of entiy and depending surfaces, faces referenced on these entities 402 were not converted.” FIXED
R5817:”Sometimes in Open/Save dialog click on button Open/Save has no effect”FIXED R5818:”The cad file is not loaded automatically in the program when we open the program,
Display first Load CAD file action is selected” FIXED R5819:”We have a problem with creating text files in Inspect3D after installing the version
V.5.5.0.4. Now the software creates an UCS2 output from the text file and we can only work with an Ansi or an UTF8 output.Can you please help us to solve this problem?” FIXED
R5820:”The results displayed in the parameter window grid have bad refresh for variable actions if fields are empties” FIXED
R5796:”Pb when reopen an ops with gps from previous version. The cad files may not be visible on locked views.” #6699 FIXED
R5821:”Better management of the progress bar when convert Catia, Solidworks, Pro-e… files. Improve speed conversion.” FIXED
R5822:”Improvement of the default reference numbering for the new actions” FIXED R5824:”Color of the deviation may not be properly calculated when the maximum material
condition is applied on the referenced element” FIXED
VDD_INCA3D_English_2015-09-28_V_5_5_0_7.doc Page 18 of 22 Form I3D-VDD001
Modifications & Bug fixes (V5506 – 2015-09-08):
Ability to manage LMC (least material condition) in GD&T evaluation
Ability to add MMC or LMC Bonus on tolerance from the dimensionnal result of another measured action (access in yellow “+” action parameter”
Graphical Report o Ability to manage visibility and transparency of each CAD file separately in each view
o
Fixed Bugs:
R5827:”When load an old gps file, it can append that the cad file is not displayed when open the
ops.” FIXED R5829:”When create a new measured circle with nominal and actual Keyboard the entity
becomes selectable in the circularity action even if no probed data are available.” FIXED R5825:”Bad display of temporary torus in the graphic (kb action)” FIXED
VDD_INCA3D_English_2015-09-28_V_5_5_0_7.doc Page 19 of 22 Form I3D-VDD001
R5834:”I3dDriver.log : Close Session comment is writting inside even if Ending date is ellapsed. Normally the file should not be in the HLM.” FIXED
R5835:”Faro Tracker: When target is not visible by the tracker, do not allow single point probing” FIXED
R5837:”Open operation sequence with 2 Load Cad files. In View parameters, Cad files visibility, if switch between the 2 Load Cad and click on Transparency : error message "Index List out of bounds"” FIXED
R5838:”Management of the default entities referenced when create a new action in the operation sequence” FIXED
R5839:”Automatic repetition of the last material position use when create a new GDT action.” FIXED
R5843:”Old MORA Milling ZAK: Calculation failed after all positions calibrated” FIXED
Modifications & Bug fixes (V5507 – 2015-09-28):
Some global graphical parameters have been move to configuration module
Filtering ability in action by list o User can type in filter in the list of action to filter the list, in example below user gets only
entity containing “circ” and “nom”
o
o
New action: Extrem point by a list of entities
VDD_INCA3D_English_2015-09-28_V_5_5_0_7.doc Page 20 of 22 Form I3D-VDD001
Management of optimzed head coordinate system o Ability to calculate an optimized head coordinate system from already calibrated head
position
o Inca3D gives as a result the calculate orientation of the head and the angle deviation
between nominal orientation and actual orientation.
o When the head coordinate system is optimized the icon of the head coordinate system switch from
blue to green o Optimized head coordinate sytem can also be
set/reset in the head coordinate system window. In this case all probe orientation are used to calculate the actual head orientation.
VDD_INCA3D_English_2015-09-28_V_5_5_0_7.doc Page 21 of 22 Form I3D-VDD001
Ability to activate only Translation of the machine alignment o Machine alignment light become half green/red
LOAD CAD action : Ability open containing folder
Wishes Done: R5844:”Inside Load CAD file operation, in the list, each CAD file should owns an hint with its
complete name (no "…") and a popup menu to open its disk directory.” DONE R5860:”Milling with MORA ZAK Milling + ANC40: if head angles are different than in Change tool,
allow user to keep current angles before starting milling in Teach&Learn mode” DONE R5858:”Translation/Rotation/Zoom parameter of view use when using keyboard arrow key must
be saved globally and not per views” DONE R5872:”Ability to search extrem point from a list of entities and not only from entities containing a
list of points” DONE
Fixed Bugs: R5850:”I++ DME and not connected by default: When execute an operation sequence, probe
compensation is wrong” FIXED R5849:”Execution time set to stupid value if run a report action in teach and learn mode” FIXED R5853:”When probing a point with SB counter we receive several points in Inca (3 or 4)” FIXED R5859:”Label format editor : The first displayed label is completly black from time to time. I need
to click it anew to see it.” FIXED R5847:”Open any ops with a LOAD CAD file without GPS --> CAD file is not visible” FIXED R5861:”MORA ZAK Milling + ANC40: When start milling from a line without IJK defined, GNC
used offset of tool using latest IJK defined instead of offset of current head orientation” FIXED
R5857:”Zoom parameter of view used when using the mouse wheel it too big per default. Set it to 1.2 instead of 1.5” FIXED
R5866:”A global calculation of the operation sequence is performed when adding entities from a macro but only the added actions have to be calculated.” FIXED
VDD_INCA3D_English_2015-09-28_V_5_5_0_7.doc Page 22 of 22 Form I3D-VDD001
R5868:”Add filtering ability in the selection lists of "By point", GD&T profile, exterm points operations …
Click in the list and keyboard f.i : pt + 32 then only operations that contains text "pt" and "32" will be displayed in the selection list. Same functi” FIXED
R5851:”3D grid is sometimes not available ” FIXED R5867:”Export Meas to Mora Stat does not generate valid dBase files” FIXED Pb in BDEAdmin.
DBASE level need to be 5 (by default 7) R5869:”SB CNC: Operation sequence is in CNC mode. When start execution by a Machine
Param then a switch to Manual, machine parameters are not applied to the controller” FIXED
R5873:”GDT are no more exported in Mora Stat” FIXED