This information carrier contains proprietary information, which shall not be used, reproduced or disclosed to third parties without prior written authorization by FNT at Sea Services LTD. Customer NELSON Ltd. Vessel M/T VICTORY Date JULY 30, 2017 FNT 840.2/02/17/REP/30/07/17 VIBRATION & IR THERMOGRAPHY SURVEY REPORT FNT at Sea Services Ltd Apostolou Varnava 4D, 3065 Limassol Cyprus Tel: +357 99886044, Email: [email protected], Web: www.fnt.gr
Transcript
Page 1: VIBRATION & IR THERMOGRAPHY SURVEY REPORT

This information carrier contains proprietary information, which shall not

be used, reproduced or disclosed to third parties without prior written

authorization by FNT at Sea Services LTD. FNT 640.04/03/14/REP//21/5/14

Customer NELSON Ltd.

Vessel M/T VICTORY

Date JULY 30, 2017

FNT 840.2/02/17/REP/30/07/17

VIBRATION & IR THERMOGRAPHY

SURVEY REPORT

FNT at Sea Services Ltd

Apostolou Varnava 4D,

3065 Limassol

Cyprus

Tel: +357 99886044, Email: [email protected], Web: www.fnt.gr

Page 2: VIBRATION & IR THERMOGRAPHY SURVEY REPORT

This information carrier contains proprietary information, which shall not

be used, reproduced or disclosed to third parties without prior written

authorization by FNT at Sea Services LTD.

Customer NELSON LTD

Vessel M/T VICTORY

Date JULY 30, 2017

ii

FNT 840.2/02/17/REP/30/07/17

PART 1: INTRODUCTION

VESSEL: M/T VICTORY

LOCATION: Netherlands

DATE: 22nd of July 2017

TIME:

VIBRATION DATA ANALYSER USED: COMMTEST VB5

VIBRATION ANALYSIS SOFTWARE: ASCENT L2

IR CAMERA: FLIR E8

SURVEYOR: …………………………… (Vibration Analyst Cat I)

ANALYST: ……………………………….(Vibration Analyst Cat II)

SUPERVISOR: ………………………… (Vibration Analyst Cat III)

SCOPE:

41 pieces of equipment were surveyed according to customer recommendation.

43 Electrical Panels were surveyed with IR Thermography according to customer

recommendation.

In Part 2, an Exception Report of IR Thermography with findings and recommendations is

presented.

In Part 3, a complete list of all the surveyed machinery in a Vibration Executive Summary Report

is presented.

In Part 4, an Exception Report of Vibrations Analysis with findings and recommendations is

included. Furthermore, measurement tables showing the data collection points and the

corresponding .rms values (in mm/s and g) of all machinery that were rated as satisfactory can

be found. These values can be used as baseline measurements in future surveys.

SURVEY:

The survey was conducted at the port of Amsterdam, Netherlands on the 22nd of July 2017, in

machinery recommended by customer in “as found” condition.

All machinery was under normal working condition.

Based on the vibration analysis of collected data, the operating condition of 2 machinery is rated

unacceptable, 3 machinery is rated marginal and 36 machinery condition is rated satisfactory.

The satisfactory rated machinery vibrations data can be used as baseline for future

measurements or for sister ships.

Based on the IR Thermography of electrical Panels, 1 finding is rated as unacceptable, 2

findings as marginal and at 40 systems no findings were identified.

A quick look report (Doc#: FNT 840.2/01/17/REP/27/07/17) has already been delivered to

NELSON Technical Department on July 27th, 2017.

Page 3: VIBRATION & IR THERMOGRAPHY SURVEY REPORT

This information carrier contains proprietary information, which shall not

be used, reproduced or disclosed to third parties without prior written

authorization by FNT at Sea Services LTD. FNT 640.04/03/14/REP//21/5/14

Customer NELSON LTD

Vessel M/T VICTORY

Date JULY 30, 2017

FNT 840.2/02/17/REP/30/07/17

Data were analyzed and evaluation of machinery condition took place, based on broadband and

narrowband analysis. For the narrowband analysis and evaluation, the following techniques were

utilized:

- Spectrum analysis (unit mm/sec): Faults like misalignment, unbalance, looseness, mounting

issues etc. can be identified.

- Time waveform analysis: Faults like mounting issues, hitting patterns etc. can be identified.

- High frequency spectrum (unit g) and time waveform analysis: Faults like bearing wear, bearing

lubricating issues, turbo generator condition etc. can be identified.

- Demodulation spectrum and waveform analysis: Faults like bearing wear, bearings lubricating

issues, rotating looseness etc. can be identified.

For broadband analysis and evaluation, the following standards were used:

- DNV “Rules for Classification of Ships - Part 6 Chapter 15 January 2011”.

- ISO 8528-9 “Reciprocating Internal Combustion Engine Driven Alternating Current Generating Sets - Part 9 Measurement and Evaluation Of Mechanical Vibrations” - VDI 2063 “Measurement and Evaluation of Mechanical Vibrations of Reciprocating Piston

Engines and Piston Compressors”

- ISO 10816-1 “Mechanical vibration -- Evaluation of machine vibration by measurements on non-

rotating parts -- Part 1: General guidelines”

- ANSI/ASA S2.28-2009 “Guide for the Measurement and Evaluation of Broadband Vibration of

Surface Ship Auxiliary Rotating Machinery”.

Classification of severity based on international standards is defined as follows:

- Unacceptable: Machinery rated unacceptable is normally considered to have a severe

problem. Generally, the machinery should not operate until inspection or remedial action

performed.

- Marginal: Machinery rated as marginal is normally considered unsatisfactory for long-term

continuous operation. Generally, the machinery may be operated for a limited period in this

condition until a suitable opportunity arises for remedial action.

- Satisfactory (*) with observation. Machinery rated satisfactory with observation require

monitoring of operation, but is suitable for long-term continuous operation. Further remedial

actions to be undertaken in case of poor performance evidences or to be scheduled based on

recommendations.

Page 4: VIBRATION & IR THERMOGRAPHY SURVEY REPORT

This information carrier contains proprietary information, which shall not

be used, reproduced or disclosed to third parties without prior written

authorization by FNT at Sea Services LTD.

Customer NELSON LTD

Vessel M/T VICTORY

Date JULY 30, 2017

iv

FNT 840.2/02/17/REP/30/07/17

Decisions on the priority and actions on the survey recommendations are sole responsibility of

the customer.

ANNEX 1 – Data Collection Procedure

SCOPE

The scope of this Annex is to explain the steps according to which the Data Collection took place

in order to ensure the proper and standardized procedure.

Sensor Mounting

A 100mV/g transducer was used. Where possible data were collected in three directions,

horizontally, vertically and axially.

a. Axial direction: Should be

parallel to the rotation axis of the rotor (Figures 1-

2).

b. Radial Direction: These are the

Vertical and Horizontal directions and should be

perpendicular to the rotor centerline.

b.1 Vertical direction: Should be

radial to the machine surface opposite to the

machine mounting for foot mounted machinery

(Figure 1). For end mounted machinery, the

vertical direction is perpendicular to the Axial

direction and the sensor should be “facing” the

machine onto which the motor/pump, for which we

collect data, is installed (Figure 2).

c. Horizontal direction: Should be

radial to the machine surface and 90° to the

vertical direction. For vertically mounted machines

the 90° count towards the shaft rotation

movement.

Page 5: VIBRATION & IR THERMOGRAPHY SURVEY REPORT

This information carrier contains proprietary information, which shall not

be used, reproduced or disclosed to third parties without prior written

authorization by FNT at Sea Services LTD. FNT 640.04/03/14/REP//21/5/14

Customer NELSON LTD

Vessel M/T VICTORY

Date JULY 30, 2017

FNT 840.2/02/17/REP/30/07/17

Sensor Locations

Repeatability of the measurements should be ensured. For this purpose, FNT personnel is

instructed and trained to recognize the measuring locations in all kinds of machinery.

The sensor is positioned as close as it can safely be to the bearings. Figures 3.a, 3.b and 3c

present some examples. Positioning sensors on motor covers should be avoided.

Page 6: VIBRATION & IR THERMOGRAPHY SURVEY REPORT

This information carrier contains proprietary information, which shall not

be used, reproduced or disclosed to third parties without prior written

authorization by FNT at Sea Services LTD.

Customer NELSON LTD

Vessel M/T VICTORY

Date JULY 30, 2017

vi

FNT 840.2/02/17/REP/30/07/17

Nomenclature

The most common nomenclature used is presented hereafter.

MNDE: Motor non drive end, which is the free end of the motor.

MDE: Motor drive end, which is the end of the motor close to the driven machine (pump, fan, compressor

etc.)

IN BRG: Inboard bearing of the driven machine (pump, fan, compressor etc.).

OUT BRG: outboard bearing of the driven machine (pump, fan, compressor etc.).

PUMP CASING: The casing of the pump.

FAN CASING: The casing of the fan.

FOOT: Compressor’s foot.

FRAME: Compressor’s frame.

HEAD: Compressor’s cylinder head.

Units

The following units are used:

mm/s: used to measure the rms vibration level of the machinery. In general, classification of the machinery

is based on the rms value. Faults like misalignment, unbalance, looseness, mounting issues etc. can be

identified based on the used technique, the pattern and the level of the measurement.

g: used to measure machinery acceleration level. Faults like bearing wear, bearings lubricating issues,

turbo generator condition etc. can be identified based on the used technique, the pattern and the level of

the measurement.

Page 7: VIBRATION & IR THERMOGRAPHY SURVEY REPORT

This information carrier contains proprietary information, which shall not

be used, reproduced or disclosed to third parties without prior written

authorization by FNT at Sea Services LTD. FNT 640.04/03/14/REP//21/5/14

Customer NELSON LTD

Vessel M/T VICTORY

Date JULY 30, 2017

FNT 840.2/02/17/REP/30/07/17

ANNEX 2 – Plot Explanation

SCOPE

The scope of this Annex is to explain the information that is contained in the plots that are included

at Part 3 (Detail Report of Vibrations Analysis).

Units that are

used.

Overall vibration level

Machinery frequency

and harmonics

Frequency of

selected

harmonic

Vibration level of

selected harmonic

Orders of selected

frequency

Colour classification

based on vibration

level

Page 8: VIBRATION & IR THERMOGRAPHY SURVEY REPORT

This information carrier contains proprietary information, which shall not

be used, reproduced or disclosed to third parties without prior written

authorization by FNT at Sea Services LTD.

Customer NELSON LTD

Vessel M/T VICTORY

Date JULY 30, 2017

viii

FNT 840.2/02/17/REP/30/07/17

Page 9: VIBRATION & IR THERMOGRAPHY SURVEY REPORT

This information carrier contains proprietary information, which shall not

be used, reproduced or disclosed to third parties without prior written

authorization by FNT at Sea Services LTD. FNT 640.04/03/14/REP//21/5/14

Customer NELSON LTD

Vessel M/T VICTORY

Date JULY 30, 2017

FNT 840.2/02/17/REP/30/07/17

PART 2

M/T VICTORY

IR THERMOGRAPHY REPORT

Page 10: VIBRATION & IR THERMOGRAPHY SURVEY REPORT

FNT at Sea Services Ltd

Apostolou Varnava 4D, 3065 Limassol, CYPRUS

FNT 840.02/02/17/REP/24/7/17

IR Thermography Report (T03)

Company NELSON LTD Class BV Ship MT VICTORY Date Inspected 22-23/7/2017 IMO number 9260043 Location Amsterdam

Vessel Status At Port Shaft RPM

Sea State Calm

Draft Fwd 6.4 m Draft Aft 8 m

Surveyor ………………………. (Level I) Instrument FLIR E8 Analyst …………………………. (Level II) THERMAL IMAGER

SPECS

Temperature Range: -20o C – 250o C

Supervisor ………………………. (Level III) IR Resolution: 320 x 240

Accuracy: +/- 2%

Rating

UNACCEPTABLE

Item Machinery List Findings Recommendations

1.

AIR CONDITION PLANT COMPRESSOR 2 SWITCHBOARD (No1 UNIT WORKING)

Spot heating extremely high. (Heating significantly reduced after switching from Unit 1 to Unit 2)

Check for possible overload. Replace component if necessary.

MARGINAL

Item Machinery List Findings Recommendations

2. No2 E/R VENT FAN ELECTRIC MOTOR STARTER

Spots heating elevated

Check connections for looseness / corrosion.

3. No1 H. TEMP. CFW P/P ELECTRIC MOTOR STARTER(JACKET)

Spot heating elevated

Check connection for looseness / corrosion.

Page 11: VIBRATION & IR THERMOGRAPHY SURVEY REPORT

FNT at Sea Services Ltd

Apostolou Varnava 4D, 3065 Limassol, CYPRUS

FNT 840.02/02/17/REP/24/7/17

SATISFACTORY

4. ME JW CIRC. P/P ELECTRIC MOTOR STARTER

5. IGG SCRUBBER CSW P/P ELECTRIC MOTOR STARTER

6. No2 ME&GE FO CIRC P/P ELECTRIC MOTOR STARTER

7. No3 LT CFW P/P ELECTRIC MOTOR STARTER

8. No2 BOILER FEED W P/P ELECTRIC MOTOR STARTER

9. No2 BOILER FW CIRC P/P ELECTRIC MOTOR STARTER

10. No1 ME & GE FO SUPPLY P/P ELECTRIC MOTOR STARTER

11. No3 MAIN CSW P/P ELECTRIC MOTOR STARTER

12. No1 E/R VENT FAN ELECTRIC MOTOR STARTER

13. Νο1 LT CFW P/P ELECTRIC MOTOR STARTER

14. No1 DECK W SEAL P/P ELECTRIC MOTOR STARTER

15. No3 ER VENT FAN ELECTRIC MOTOR STARTER

16. No1 MAIN LO P/P ELECTRIC MOTOR STARTER

Page 12: VIBRATION & IR THERMOGRAPHY SURVEY REPORT

FNT at Sea Services Ltd

Apostolou Varnava 4D, 3065 Limassol, CYPRUS

FNT 840.02/02/17/REP/24/7/17

17. No1 FIRE BILGE & GS P/P ELECTRIC MOTOR STARTER

18. No1 AC 440 V FEEDER PANEL

19. No2 D. GEN. PANEL

20. No3 D. GEN. PANEL

21. No2 AC 440 V FEEDER PANEL

22. No2 ME & GE FO SUPPLY P/P ELECTRIC MOTOR STARTER

23. No2 H. TEMP. CFW P/P ELECTRIC MOTOR STARTER (JACKET)

24. No2 MAIN CSW P/P ELECTRIC MOTOR STARTER

25. No2 LT CFW P/P ELECTRIC MOTOR STARTER

26. No2 MAIN LO P/P ELECTRIC MOTOR STARTER

27. No2 FIRE BILGE & GS P/P ELECTRIC MOTOR STARTER

28. No1 BOILER FW CIRC P/P ELECTRIC MOTOR STARTER

29. No1 BOILER FW P/P ELECTRIC MOTOR STARTER

30. No1 MAIN CSW P/P ELECTRIC MOTOR STARTER

Page 13: VIBRATION & IR THERMOGRAPHY SURVEY REPORT

FNT at Sea Services Ltd

Apostolou Varnava 4D, 3065 Limassol, CYPRUS

FNT 840.02/02/17/REP/24/7/17

31. No1 ME&GE FO CIRC P/P ELECTRIC MOTOR STARTER

32. No1 D. GEN. PANEL

33. AC 220V FEEDER PANEL

34. No1 MAIN AIR COMPRESSOR ELECTRIC MOTOR STARTER

35. BATTERY CHARGER

36. DC 24V DIST. BOARD

37. SANITARY SPACE EXH. FAN ELECTRIC MOTOR STARTER

38. ACCOM. AIR COND. AHU FAN ELECTRIC MOTOR STARTER

39. GALLEY SUPPLY FAN ELECTRIC MOTOR STARTER

40. GALLEY EXH FAN ELECTRIC MOTOR STARTER

41. STEERING GEAR MOTOR CONTROLER No2

42. STEERING GEAR MOTOR CONTROLER No1

43.

AIR CONDITION PLANT COMPRESSOR 2 SWITCHBOARD (No2 UNIT WORKING)

Page 14: VIBRATION & IR THERMOGRAPHY SURVEY REPORT

FNT at Sea Services Ltd

Apostolou Varnava 4D, 3065 Limassol, CYPRUS

FNT 840.02/02/17/REP/24/7/17

MT VICTORY

IR THERMOGRAPHY FINDINGS REPORT

Page 15: VIBRATION & IR THERMOGRAPHY SURVEY REPORT

FNT at Sea Services Ltd

Apostolou Varnava 4D, 3065 Limassol, CYPRUS

FNT 840.02/02/17/REP/24/7/17

Equipment AIR CONDITION PLANT COMPRESSOR 2 SWITCHBOARD (No1 UNIT WORKING)

FINDINGS: RECOMMENDATIONS:

Spot heating extremely high (Heating significally reduced after switching from Unit 1 to Unit 2 -see below thermal image)

Check for possible overload. Replace component if necessary.

File name FLIR2230.jpg

Date 7/22/2017

Image Time 10:08:33 PM

Ar1

70.7

87.5 °C

75

80

85

Ar1 Max. Temperature 92.8 °C

Analysis and recommended actions:

Ar1

38.7

52.4 °C

40

45

50

Ar1 Max. Temperature 45.1 °C

Page 16: VIBRATION & IR THERMOGRAPHY SURVEY REPORT

FNT at Sea Services Ltd

Apostolou Varnava 4D, 3065 Limassol, CYPRUS

FNT 840.02/02/17/REP/24/7/17

Equipment No2 E/R VENT FAN ELECTRIC MOTOR STARTER

FINDINGS: RECOMMENDATIONS:

Spots heating elevated Check connections for looseness / corrosion.

File name FLIR1746.jpg

Date 7/22/2017

Image Time 5:47:36 PM

Sp1 Sp2

40.2

45.5 °C

42

44

Sp1 Temperature 45.5 °C

Sp2 Temperature 44.7 °C

Analysis and recommended actions:

Page 17: VIBRATION & IR THERMOGRAPHY SURVEY REPORT

FNT at Sea Services Ltd

Apostolou Varnava 4D, 3065 Limassol, CYPRUS

FNT 840.02/02/17/REP/24/7/17

Equipment No1 H. TEMP. CFW P/P ELECTRIC MOTOR STARTER(JACKET)

FINDINGS: RECOMMENDATIONS:

Spot heating elevated Check connection for looseness / corrosion.

File name FLIR1792.jpg

Date 7/22/2017

Image Time 6:03:50 PM

Ar1

41.7

52.4 °C

45

50

Ar1 Max. Temperature 53.0 °C

Analysis and recommended actions:

Page 18: VIBRATION & IR THERMOGRAPHY SURVEY REPORT

This information carrier contains proprietary information, which shall not

be used, reproduced or disclosed to third parties without prior written

authorization by FNT at Sea Services LTD.

Customer NELSON LTD

Vessel M/T VICTORY

Date JULY 30, 2017

x

FNT 840.2/02/17/REP/30/07/17

PART 3

M/T VICTORY

EXECUTIVE SUMMARY

MACHINERY VIBRATION ANALYSIS

Page 19: VIBRATION & IR THERMOGRAPHY SURVEY REPORT

FNT at SEA SERVICES Ltd

1 FNT 840.2/02/17/REP/30/07/17

Executive Summary Report (T04)

Company NELSON LTD Class Bureau Veritas

Ship VICTORY Last CM Survey 22 July 2017

IMO Number 9260043 Location Netherlands

Vessel Status At Port

Sea State Calm Shaft RPM 0

Draft Fwd 6.4 m Draft Aft 8 m

Item Machinery List Findings Recommendations Rating Pg

1. Main C.S.W. Pump No 1

- Excessive vibration level was measured at motor n.d.e. and d.e. radially. This is due to motor heavy unbalance. - Motor n.d.e. wear frequencies were measured at demodulated spectrum. This is an indication of motor n.d.e. bearing initial stage of wear.

- Perform motor balancing. - Although bearing wear is at initial stage it is recommended to be replaced when motor balancing is performed.

Unacceptable 7

2. Main C.S.W. Pump No 3

- Excessive radial vibration level vibration level was measured at motor n.d.e. Furthermore, excessive directional (horizontal) vibration level was measured at motor d.e. Possible causes for this include coupling wear, angular misalignment or mounting issues.

- Check coupling condition. - Inspect and correct alignment. - Check mounting for soft foot as per attached instructions.

Unacceptable 11

3. AUX Boiler F.W. Pump

No 1

- Motor d.e. wear frequencies and increased high frequency energy was measured. This is an indication of motor d.e. bearing wear. - Increased directional (horizontal) vibration level was measured at motor n.d.e and d.e. This is an indication of coupling wear or mounting issues. - Increased high frequency energy was measured at pump inboard and outboard bearings. This is an indication of pump bearings lubrication issues.

- Schedule motor d.e. bearing replacement. - Check coupling condition - Check motor mounting bolts tightness. - Lubricate pump inboard and outboard bearings in order to reduce friction forces. Pump bearings condition will be trended.

Marginal 15

4. AUX Boiler F.W. Pump

No 2

- Increased directional (horizontal) vibration level was measured at motor n.d.e and d.e. This is an indication of coupling wear or mounting issues.

- Check coupling condition - Check motor mounting bolts tightness.

Marginal 19

5. F.D. Fan

- Increased radial and axial vibration level was measured at motor and fan casing. This is an indication of fan impeller moderate mass unbalance.

- Clean and inspect fan impeller condition.

Marginal 23

6. Air Conditioning Compressor No 2

- Relatively increased directional (horizontal) vibration level was measured at motor and compressor feet. This is an indication of mounting issues and sheaves eccentricity.

- Check motor and compressor mounting bolts tightness. - Check sheaves eccentricity.

Satisfactory* 27

7. Bilge Fire & G.S. Pump

No 2

- Motor n.d.e. bearing wear frequencies and increased high frequency vibration level and was measured. This is an indication of initial stage of motor n.d.e. bearing wear.

- Do not replace motor n.d.e. bearing at this stage of wear. Bearing condition will be trended in future measurements.

Satisfactory* 31

8. Boiler Water Circ. Pump

No 1

- Increased directional (horizontal) vibration level was measured at motor and pump. This is an indication of coupling wear or mounting issues.

- Check coupling condition. - Check motor and pump mounting bolts tightness.

Satisfactory* 35

9. D/G Turbo Charger No 1 - Relatively increased (marginally above - Schedule air filter cleaning or Satisfactory* 39

Page 20: VIBRATION & IR THERMOGRAPHY SURVEY REPORT

FNT at SEA SERVICES Ltd

2 FNT 840.2/02/17/REP/30/07/17

recommended level) high frequency vibration level was measured at air filter. This is an indication of restricted air flow or air filter mounting issues.

replacement. - Check filter casing mounting condition.

10. FRAMO Hydr. Power

Pack No 1

- The vibration forcing frequency is at 9th order of running speed, which is related to the number of pump pistons. Although vibration level is marginally above recommended low limit (ISO 2372), that type of vibration is typical for axial piston pumps.

- Pump vibration level will be trended. Satisfactory* 43

11. M/E Aux. Blower No 1 - Relatively increased vibration level was measured radially at motor. This is an indication of motor light mass unbalance.

- Motor unbalance level and caused vibraton is recommended to be trended at next measurement.

Satisfactory* 47

12. Main C.S.W. Pump No 2 - Increased directional (vertical) vibration level was measured at motor n.d.e. and d.e. This is an indication of mounting issues.

- Check coupling condition. - Check mounting bolts even torque tightness.

Satisfactory* 51

13. Air Conditioning Compressor No 1

No findings None Satisfactory

14. Bilge Fire & G.S. Pump

No 1 No findings None Satisfactory

15. Boiler Water Circ. Pump

No 2 No findings None Satisfactory

16. D/G Alternator No 1 No findings None Satisfactory

17. D/G Alternator No 2 No findings None Satisfactory

18. D/G Alternator No 3 No findings None Satisfactory

19. D/G Turbo Charger No 2 No findings None Satisfactory

20. D/G Turbo Charger No 3 No findings None Satisfactory

21. E/R Fan No 1 No findings None Satisfactory

22. E/R Fan No 2 No findings None Satisfactory

23. E/R Fan No 3 No findings None Satisfactory

24. E/R Fan No 4 No findings None Satisfactory

25. Emergency Fire Pump No findings None Satisfactory

26. FRAMO Hydr. Power

Pack No 2 No findings None Satisfactory

27. H.T. Cooling F.W. Pump

No 1 No findings None Satisfactory

28. H.T. Cooling F.W. Pump

No 2 No findings None Satisfactory

29. I.G. Fan No findings None Satisfactory

30. L.T. Cooling F.W. Pump

No 1 No findings None Satisfactory

31. L.T. Cooling F.W. Pump

No 2 No findings None Satisfactory

32. L.T. Cooling F.W. Pump

No 3 No findings None Satisfactory

33. M/E & G/E F.O. Circ.

Pump No 2 No findings None Satisfactory

34. M/E & G/E F.O. Supply

Pump No 1 No findings None Satisfactory

35. M/E Aux. Blower No 2 No findings None Satisfactory

36. M/E Lub. Oil Pump No 1 No findings None Satisfactory

37. M/E Lub. Oil Pump No 2 No findings None Satisfactory

38. Main L.O. Purifier No 2 No findings None Satisfactory

39. Scrubber C.S.W. Pump No findings None Satisfactory

40. Steering Gear Motor No

1 No findings None Satisfactory

41. Steering Gear Motor No

2 No findings None Satisfactory

Page 21: VIBRATION & IR THERMOGRAPHY SURVEY REPORT

FNT at SEA SERVICES Ltd

3 FNT 840.2/02/17/REP/30/07/17

Note:

Unacceptable rating machine require actions as soon as possible. Machines rated unacceptable are normally considered to have a severe problem. Generally, the machine should not operate until inspection or remedy action performed. Marginal rating machine require actions to be schedule. Machines rated marginal are normally considered unsatisfactory for long-term continuous operation. Generally, the machine may be operated for a limited period in this condition until a suitable opportunity arises for remedial action. Broadband (rms vibration energy power) and narrowband (spectrum, time waveform, demodulation and phase) analysis was performed. The following standards was used:

ISO 10816-3 “Mechanical vibration — Evaluation of machine vibration by measurements on non-rotating parts — Part 3: Industrial machines with nominal power above 15 kW and nominal speeds between 120 r/min and 15 000 r/min when measured in situ

ISO 10816-7 “Mechanical vibration — Evaluation of machine vibration by measurements on non-rotating parts — Part 7: Rotodynamic pumps for industrial applications, including measurements on rotating shafts

ISO 10816-8 “Mechanical vibration — Evaluation of machine vibration by measurements on non-rotating parts — Part 8: Reciprocating compressor systems”

ANSI/ASA S2.28-2009 “Guide for the Measurement and Evaluation of Broadband Vibration of Surface Ship Auxiliary Rotating Machinery”

Page 22: VIBRATION & IR THERMOGRAPHY SURVEY REPORT

FNT at SEA SERVICES Ltd

4 FNT 840.2/02/17/REP/30/07/17

Page 23: VIBRATION & IR THERMOGRAPHY SURVEY REPORT

FNT at SEA SERVICES Ltd

5 FNT 840.2/02/17/REP/30/07/17

PART 4

M/T VICTORY

MACHINERY VIBRATION ANALYSIS

EXCEPTION REPORT

Page 24: VIBRATION & IR THERMOGRAPHY SURVEY REPORT

FNT at SEA SERVICES Ltd

6 FNT 840.2/02/17/REP/30/07/17

Page 25: VIBRATION & IR THERMOGRAPHY SURVEY REPORT

FNT at SEA SERVICES Ltd

7 FNT 840.2/02/17/REP/30/07/17

Machinery Vibration Report

Company NELSON LTD Class Bureau Veritas

Ship VICTORY Last Inspected 22 July 2017

Machinery Rating

Main C.S.W. Pump No 1 Unacceptable

Vessel Condition

Machinery Speed 1793 rpm

Status : At Port

Sea State: Calm Shaft RPM: 0 Machinery Load

Draft Fwd: 6.4 m Draft Aft: 8 m

Fault Type(s)

Unbalancing, Bearing Wear

Findings

- Excessive vibration level was measured at motor n.d.e. and d.e. radially. This is due to motor heavy unbalance. - Motor n.d.e. wear frequencies were measured at demodulated spectrum. This is an indication of motor n.d.e. bearing initial stage of wear.

Recommendations

- Perform motor balancing. - Although bearing wear is at initial stage it is recommended to be replaced when motor balancing is performed.

Historical Data

Date Surveyed Rating Fault Type(s)

Page 26: VIBRATION & IR THERMOGRAPHY SURVEY REPORT

FNT at SEA SERVICES Ltd

8 FNT 840.2/02/17/REP/30/07/17

Summary Measurements Table

Main CSW Pump No1

Location Vibration

Level Units Date Remarks

MNDE - Horizontal 1.005 g RMS 7/22/2017

MNDE - Horizontal 44.8 mm/s RMS 7/22/2017

MNDE - Vertical 0.9772 g RMS 7/22/2017

MNDE - Vertical 41.07 mm/s RMS 7/22/2017

MNDE - Axial 0.661 g RMS 7/22/2017

MNDE - Axial 10.77 mm/s RMS 7/22/2017

MDE - Horizontal 0.5398 g RMS 7/22/2017

MDE - Horizontal 22.53 mm/s RMS 7/22/2017

MDE - Vertical 0.5638 g RMS 7/22/2017

MDE - Vertical 24.07 mm/s RMS 7/22/2017

MDE - Axial 0.5917 g RMS 7/22/2017

MDE - Axial 9.061 mm/s RMS 7/22/2017

Pump casing - Horizontal 0.833 g RMS 7/22/2017

Pump casing - Horizontal 7.153 mm/s RMS 7/22/2017

Pump casing - Vertical 0.4527 g RMS 7/22/2017

Pump casing - Vertical 2.297 mm/s RMS 7/22/2017

Pump casing - Axial 0.969 g RMS 7/22/2017

Pump casing - Axial 10.42 mm/s RMS 7/22/2017

Page 27: VIBRATION & IR THERMOGRAPHY SURVEY REPORT

FNT at SEA SERVICES Ltd

9 FNT 840.2/02/17/REP/30/07/17

Vibration Analysis Plots

Motor n.d.e. vibration spectrum in horizontal and vertical direction

Motor d.e. vibration spectrum in horizontal and vertical direction

Page 28: VIBRATION & IR THERMOGRAPHY SURVEY REPORT

FNT at SEA SERVICES Ltd

10 FNT 840.2/02/17/REP/30/07/17

Motor n.d.e bearing demodulated spectrum in horizontal direction

Page 29: VIBRATION & IR THERMOGRAPHY SURVEY REPORT

FNT at SEA SERVICES Ltd

11 FNT 840.2/02/17/REP/30/07/17

Machinery Vibration Report

Company NELSON LTD Class Bureau Veritas

Ship VICTORY Last Inspected 22 July 2017

Machinery Rating

Main C.S.W. Pump No 3 Unacceptable

Vessel Condition

Machinery Speed 1791 rpm

Status : At Port

Sea State: Calm Shaft RPM: 0 Machinery Load

Draft Fwd: 6.4 m Draft Aft: 8 m

Fault Type(s)

Coupling Fault

Findings

- Excessive radial vibration level vibration level was measured at motor n.d.e. Furthermore, excessive directional (horizontal) vibration level was measured at motor d.e. Possible causes for this include coupling wear, angular misalignment or mounting issues.

Recommendations

- Check coupling condition. - Inspect and correct alignment. - Check mounting for soft foot as per attached instructions.

Historical Data

Date Surveyed Rating Fault Type(s)

Page 30: VIBRATION & IR THERMOGRAPHY SURVEY REPORT

FNT at SEA SERVICES Ltd

12 FNT 840.2/02/17/REP/30/07/17

Summary Measurements Table

Main CSW Pump No3

Location Vibration

Level Units Date Remarks

MNDE - Horizontal 0.8192 g RMS 7/22/2017

MNDE - Horizontal 35.43 mm/s RMS 7/22/2017

MNDE - Vertical 0.9134 g RMS 7/22/2017

MNDE - Vertical 33.39 mm/s RMS 7/22/2017

MNDE - Axial 0.5817 g RMS 7/22/2017

MNDE - Axial 17.71 mm/s RMS 7/22/2017

MDE - Horizontal 0.7688 g RMS 7/22/2017

MDE - Horizontal 34.67 mm/s RMS 7/22/2017

MDE - Vertical 0.3642 g RMS 7/22/2017

MDE - Vertical 4.853 mm/s RMS 7/22/2017

MDE - Axial 0.3484 g RMS 7/22/2017

MDE - Axial 5.681 mm/s RMS 7/22/2017

Pump casing - Horizontal 0.4685 g RMS 7/22/2017

Pump casing - Horizontal 8.415 mm/s RMS 7/22/2017

Pump casing - Vertical 0.3617 g RMS 7/22/2017

Pump casing - Vertical 3.598 mm/s RMS 7/22/2017

Pump casing - Axial 0.3873 g RMS 7/22/2017

Pump casing - Axial 6.779 mm/s RMS 7/22/2017

Page 31: VIBRATION & IR THERMOGRAPHY SURVEY REPORT

FNT at SEA SERVICES Ltd

13 FNT 840.2/02/17/REP/30/07/17

Vibration Analysis Plots

Motor n.d.e. vibration spectrum in horizontal direction

Motor n.d.e. vibration spectrum in vertical direction

Page 32: VIBRATION & IR THERMOGRAPHY SURVEY REPORT

FNT at SEA SERVICES Ltd

14 FNT 840.2/02/17/REP/30/07/17

Motor d.e. vibration spectrum in horizontal direction

Motor d.e. vibration spectrum in vertical direction

Page 33: VIBRATION & IR THERMOGRAPHY SURVEY REPORT

FNT at SEA SERVICES Ltd

15 FNT 840.2/02/17/REP/30/07/17

Machinery Vibration Report

Company NELSON LTD Class Bureau Veritas

Ship VICTORY Last Inspected 22 July 2017

Machinery Rating

AUX Boiler F.W. Pump No 1 Marginal

Vessel Condition

Machinery Speed 3591 rpm

Status : At Port

Sea State: Calm Shaft RPM: 0 Machinery Load

Draft Fwd: 6.4 m Draft Aft: 8 m

Fault Type(s)

Bearing Wear, Mounting Issues, Bearing Insufficient Lubrication

Findings

- Motor d.e. wear frequencies and increased high frequency energy was measured. This is an indication of motor d.e. bearing wear. - Increased directional (horizontal) vibration level was measured at motor n.d.e and d.e. This is an indication of coupling wear or mounting issues. - Increased high frequency energy was measured at pump inboard and outboard bearings. This is an indication of pump bearings lubrication issues.

Recommendations

- Schedule motor d.e. bearing replacement. - Check coupling condition - Check motor mounting bolts tightness. - Lubricate pump inboard and outboard bearings in order to reduce friction forces. Pump bearings condition will be trended.

Historical Data

Date Surveyed Rating Fault Type(s)

Page 34: VIBRATION & IR THERMOGRAPHY SURVEY REPORT

FNT at SEA SERVICES Ltd

16 FNT 840.2/02/17/REP/30/07/17

Summary Measurements Table

Boiler Feed Water Pump No1

Location Vibration

Level Units Date Remarks

MNDE - Horizontal 2.818 g RMS 7/22/2017

MNDE - Horizontal 34.54 mm/s RMS 7/22/2017

MNDE - Vertical 3.117 g RMS 7/22/2017

MNDE - Vertical 7.821 mm/s RMS 7/22/2017

MDE - Horizontal 4.952 g RMS 7/22/2017

MDE - Horizontal 23.69 mm/s RMS 7/22/2017

MDE - Vertical 3.252 g RMS 7/22/2017

MDE - Vertical 3.612 mm/s RMS 7/22/2017

MDE - Axial 5.191 g RMS 7/22/2017

MDE - Axial 5.286 mm/s RMS 7/22/2017

Pump Inboard Bearing - Horizontal 3.107 g RMS 7/22/2017

Pump Inboard Bearing - Horizontal 10.33 mm/s RMS 7/22/2017

Pump Inboard Bearing - Vertical 4.09 g RMS 7/22/2017

Pump Inboard Bearing - Vertical 3.836 mm/s RMS 7/22/2017

Pump Inboard Bearing - Axial 2.103 g RMS 7/22/2017

Pump Inboard Bearing - Axial 3.77 mm/s RMS 7/22/2017

Pump Outboard Bearing - Horizontal 3.916 g RMS 7/22/2017

Pump Outboard Bearing - Horizontal 7.177 mm/s RMS 7/22/2017

Pump Outboard Bearing - Vertical 3.564 g RMS 7/22/2017

Pump Outboard Bearing - Vertical 3.734 mm/s RMS 7/22/2017

Pump Outboard Bearing - Axial 7.397 g RMS 7/22/2017

Pump Outboard Bearing - Axial 4.314 mm/s RMS 7/22/2017

Page 35: VIBRATION & IR THERMOGRAPHY SURVEY REPORT

FNT at SEA SERVICES Ltd

17 FNT 840.2/02/17/REP/30/07/17

Vibration Analysis Plots

Motor n.d.e vibration spectrum in horizontal direction (red line) and vertical (blue line) direction

Motor n.d.e vibration spectrum in horizontal direction (red line) and vertical (blue line) direction

Page 36: VIBRATION & IR THERMOGRAPHY SURVEY REPORT

FNT at SEA SERVICES Ltd

18 FNT 840.2/02/17/REP/30/07/17

Motor d.e. vibration High Frequency Spectrum and demodulation spectrum in axial direction

Pump inboard and outboard bearing high frequency spectrum

Page 37: VIBRATION & IR THERMOGRAPHY SURVEY REPORT

FNT at SEA SERVICES Ltd

19 FNT 840.2/02/17/REP/30/07/17

Machinery Vibration Report

Company NELSON LTD Class Bureau Veritas

Ship VICTORY Last Inspected 22 July 2017

Machinery Rating

AUX Boiler F.W. Pump No 2 Marginal

Vessel Condition

Machinery Speed 3597 rpm

Status : At Port

Sea State: Calm Shaft RPM: 0 Machinery Load

Draft Fwd: 6.4 m Draft Aft: 8 m

Fault Type(s)

Mounting Issues

Findings

- Increased directional (horizontal) vibration level was measured at motor n.d.e and d.e. This is an indication of coupling wear or mounting issues.

Recommendations

- Check coupling condition - Check motor mounting bolts tightness.

Historical Data

Date Surveyed Rating Fault Type(s)

Page 38: VIBRATION & IR THERMOGRAPHY SURVEY REPORT

FNT at SEA SERVICES Ltd

20 FNT 840.2/02/17/REP/30/07/17

Summary Measurements Table

Boiler Feed Water Pump No2

Location Vibration

Level Units Date Remarks

MNDE - Horizontal 1.132 g RMS 7/22/2017

MNDE - Horizontal 27.96 mm/s RMS 7/22/2017

MNDE - Vertical 0.4633 g RMS 7/22/2017

MNDE - Vertical 2.113 mm/s RMS 7/22/2017

MDE - Horizontal 1.08 g RMS 7/22/2017

MDE - Horizontal 26.49 mm/s RMS 7/22/2017

MDE - Vertical 0.435 g RMS 7/22/2017

MDE - Vertical 2.027 mm/s RMS 7/22/2017

MDE - Axial 0.4287 g RMS 7/22/2017

MDE - Axial 3.325 mm/s RMS 7/22/2017

Pump Inboard Bearing - Horizontal 0.8766 g RMS 7/22/2017

Pump Inboard Bearing - Horizontal 9.414 mm/s RMS 7/22/2017

Pump Inboard Bearing - Vertical 0.8473 g RMS 7/22/2017

Pump Inboard Bearing - Vertical 5.586 mm/s RMS 7/22/2017

Pump Inboard Bearing - Axial 0.4584 g RMS 7/22/2017

Pump Inboard Bearing - Axial 2.528 mm/s RMS 7/22/2017

Pump Outboard Bearing - Horizontal 0.9235 g RMS 7/22/2017

Pump Outboard Bearing - Horizontal 6.163 mm/s RMS 7/22/2017

Pump Outboard Bearing - Vertical 0.6458 g RMS 7/22/2017

Pump Outboard Bearing - Vertical 4.491 mm/s RMS 7/22/2017

Page 39: VIBRATION & IR THERMOGRAPHY SURVEY REPORT

FNT at SEA SERVICES Ltd

21 FNT 840.2/02/17/REP/30/07/17

Vibration Analysis Plots

Motor n.d.e vibration Spectrum in horizontal direction

Motor n.d.e vibration Spectrum in vertical direction

Page 40: VIBRATION & IR THERMOGRAPHY SURVEY REPORT

FNT at SEA SERVICES Ltd

22 FNT 840.2/02/17/REP/30/07/17

Motor d.e vibration Spectrum in horizontal direction

Motor d.e vibration Spectrum in vertical direction

Page 41: VIBRATION & IR THERMOGRAPHY SURVEY REPORT

FNT at SEA SERVICES Ltd

23 FNT 840.2/02/17/REP/30/07/17

Machinery Vibration Report

Company NELSON LTD Class Bureau Veritas

Ship VICTORY Last Inspected 22 July 2017

Machinery Rating

F.D. Fan Marginal

Vessel Condition

Machinery Speed 1800 rpm

Status : At Port

Sea State: Calm Shaft RPM: 0 Machinery Load

Draft Fwd: 6.4 m Draft Aft: 8 m

Fault Type(s)

Unbalancing

Findings

- Increased radial and axial vibration level was measured at motor and fan casing. This is an indication of fan impeller moderate mass unbalance.

Recommendations

- Clean and inspect fan impeller condition.

Historical Data

Date Surveyed Rating Fault Type(s)

Page 42: VIBRATION & IR THERMOGRAPHY SURVEY REPORT

FNT at SEA SERVICES Ltd

24 FNT 840.2/02/17/REP/30/07/17

Summary Measurements Table

Boiler FD Fan

Location Vibration

Level Units Date Remarks

MNDE - Horizontal 0.5759 g RMS 7/22/2017

MNDE - Horizontal 18.97 mm/s RMS 7/22/2017

MNDE - Vertical 0.5698 g RMS 7/22/2017

MNDE - Vertical 19.99 mm/s RMS 7/22/2017

MNDE - Axial 0.4497 g RMS 7/22/2017

MNDE - Axial 11.49 mm/s RMS 7/22/2017

MDE - Horizontal 0.55 g RMS 7/22/2017

MDE - Horizontal 12.77 mm/s RMS 7/22/2017

MDE - Vertical 0.5905 g RMS 7/22/2017

MDE - Vertical 16.25 mm/s RMS 7/22/2017

MDE - Axial 0.3826 g RMS 7/22/2017

MDE - Axial 3.97 mm/s RMS 7/22/2017

Fan casing - Horizontal 0.5354 g RMS 7/22/2017

Fan casing - Horizontal 13.58 mm/s RMS 7/22/2017

Fan casing - Vertical 0.5518 g RMS 7/22/2017

Fan casing - Vertical 17.24 mm/s RMS 7/22/2017

Fan casing - Axial 1.095 g RMS 7/22/2017

Fan casing - Axial 8.013 mm/s RMS 7/22/2017

Page 43: VIBRATION & IR THERMOGRAPHY SURVEY REPORT

FNT at SEA SERVICES Ltd

25 FNT 840.2/02/17/REP/30/07/17

Vibration Analysis Plots

Fan vibration Spectrum in horizontal direction

Fan vibration Spectrum in vertical direction

Page 44: VIBRATION & IR THERMOGRAPHY SURVEY REPORT

FNT at SEA SERVICES Ltd

26 FNT 840.2/02/17/REP/30/07/17

Fan vibration Spectrum in axial direction

Page 45: VIBRATION & IR THERMOGRAPHY SURVEY REPORT

FNT at SEA SERVICES Ltd

27 FNT 840.2/02/17/REP/30/07/17

Machinery Vibration Report

Company NELSON LTD Class Bureau Veritas

Ship VICTORY Last Inspected 22 July 2017

Machinery Rating

Air Conditioning Compressor No 2 Satisfactory*

Vessel Condition

Machinery Speed 1797 rpm

Status : At Port

Sea State: Calm Shaft RPM: 0 Machinery Load

Draft Fwd: 6.4 m Draft Aft: 8 m

Fault Type(s)

Mounting Issues

Findings

- Relatively increased directional (horizontal) vibration level was measured at motor and compressor feet. This is an indication of mounting issues and sheaves eccentricity.

Recommendations

- Check motor and compressor mounting bolts tightness. - Check sheaves eccentricity.

Historical Data

Date Surveyed Rating Fault Type(s)

Page 46: VIBRATION & IR THERMOGRAPHY SURVEY REPORT

FNT at SEA SERVICES Ltd

28 FNT 840.2/02/17/REP/30/07/17

Summary Measurements Table

Air Condition Compressor No2

Location Vibration

Level Units Date Remarks

MNDE - Horizontal 0.4831 g RMS 7/22/2017

MNDE - Horizontal 16.23 mm/s RMS 7/22/2017

MNDE - Vertical 0.4003 g RMS 7/22/2017

MNDE - Vertical 4.784 mm/s RMS 7/22/2017

MDE - Horizontal 0.4687 g RMS 7/22/2017

MDE - Horizontal 17.15 mm/s RMS 7/22/2017

MDE - Vertical 0.3615 g RMS 7/22/2017

MDE - Vertical 5.674 mm/s RMS 7/22/2017

MDE - Axial 0.2257 g RMS 7/22/2017

MDE - Axial 3.469 mm/s RMS 7/22/2017

FOOT1 - Horizontal 0.3545 g RMS 7/22/2017

FOOT1 - Horizontal 10.84 mm/s RMS 7/22/2017

FOOT1 - Axial 0.3773 g RMS 7/22/2017

FOOT1 - Axial 1.94 mm/s RMS 7/22/2017

FOOT2 - Horizontal 0.3819 g RMS 7/22/2017

FOOT2 - Horizontal 10.66 mm/s RMS 7/22/2017

FOOT2 - Vertical 0.4346 g RMS 7/22/2017

FOOT2 - Vertical 3.962 mm/s RMS 7/22/2017

FOOT2 - Axial 0.3565 g RMS 7/22/2017

FOOT2 - Axial 1.957 mm/s RMS 7/22/2017

FRAME - Horizontal 0.5151 g RMS 7/22/2017

FRAME - Horizontal 12.45 mm/s RMS 7/22/2017

FRAME - Vertical 0.7202 g RMS 7/22/2017

FRAME - Vertical 5.324 mm/s RMS 7/22/2017

FRAME - Axial 0.6105 g RMS 7/22/2017

FRAME - Axial 4.463 mm/s RMS 7/22/2017

Page 47: VIBRATION & IR THERMOGRAPHY SURVEY REPORT

FNT at SEA SERVICES Ltd

29 FNT 840.2/02/17/REP/30/07/17

Vibration Analysis Plots

Motor n.d.e vibration Spectrum in horizontal direction

Motor d.e vibration Spectrum in horizontal direction

Page 48: VIBRATION & IR THERMOGRAPHY SURVEY REPORT

FNT at SEA SERVICES Ltd

30 FNT 840.2/02/17/REP/30/07/17

Page 49: VIBRATION & IR THERMOGRAPHY SURVEY REPORT

FNT at SEA SERVICES Ltd

31 FNT 840.2/02/17/REP/30/07/17

Machinery Vibration Report

Company NELSON LTD Class Bureau Veritas

Ship VICTORY Last Inspected 22 July 2017

Machinery Rating

Bilge Fire & G.S. Pump No 2 Satisfactory*

Vessel Condition

Machinery Speed 1796 rpm

Status : At Port

Sea State: Calm Shaft RPM: 0 Machinery Load

Draft Fwd: 6.4 m Draft Aft: 8 m

Fault Type(s)

Bearing Wear

Findings

- Motor n.d.e. bearing wear frequencies and increased high frequency vibration level and was measured. This is an indication of initial stage of motor n.d.e. bearing wear.

Recommendations

- Do not replace motor n.d.e. bearing at this stage of wear. Bearing condition will be trended in future measurements.

Historical Data

Date Surveyed Rating Fault Type(s)

Page 50: VIBRATION & IR THERMOGRAPHY SURVEY REPORT

FNT at SEA SERVICES Ltd

32 FNT 840.2/02/17/REP/30/07/17

Summary Measurements Table

Bilge Fire & GS Pump No2

Location Vibration

Level Units Date Remarks

MNDE - Horizontal 1.739 g RMS 7/22/2017

MNDE - Horizontal 6.96 mm/s RMS 7/22/2017

MNDE - Vertical 1.517 g RMS 7/22/2017

MNDE - Vertical 2.819 mm/s RMS 7/22/2017

MNDE - Axial 2.016 g RMS 7/22/2017

MNDE - Axial 5.937 mm/s RMS 7/22/2017

MDE - Horizontal 0.4832 g RMS 7/22/2017

MDE - Horizontal 4.329 mm/s RMS 7/22/2017

MDE - Vertical 0.5248 g RMS 7/22/2017

MDE - Vertical 2.227 mm/s RMS 7/22/2017

MDE - Axial 0.7419 g RMS 7/22/2017

MDE - Axial 1.739 mm/s RMS 7/22/2017

Pump casing - Horizontal 0.5143 g RMS 7/22/2017

Pump casing - Horizontal 2.888 mm/s RMS 7/22/2017

Pump casing - Vertical 0.6114 g RMS 7/22/2017

Pump casing - Vertical 0.9381 mm/s RMS 7/22/2017

Pump casing - Axial 1.285 g RMS 7/22/2017

Pump casing - Axial 1.573 mm/s RMS 7/22/2017

Page 51: VIBRATION & IR THERMOGRAPHY SURVEY REPORT

FNT at SEA SERVICES Ltd

33 FNT 840.2/02/17/REP/30/07/17

Vibration Analysis Plots

Motor n.d.e. vibration High Frequency Spectrum in axial direction

Motor n.d.e. vibration Demodulated Spectrum in axial direction

Page 52: VIBRATION & IR THERMOGRAPHY SURVEY REPORT

FNT at SEA SERVICES Ltd

34 FNT 840.2/02/17/REP/30/07/17

Page 53: VIBRATION & IR THERMOGRAPHY SURVEY REPORT

FNT at SEA SERVICES Ltd

35 FNT 840.2/02/17/REP/30/07/17

Machinery Vibration Report

Company NELSON LTD Class Bureau Veritas

Ship VICTORY Last Inspected 22 July 2017

Machinery Rating

Boiler Water Circ. Pump No 1 Satisfactory*

Vessel Condition

Machinery Speed 3551 rpm

Status : At Port

Sea State: Calm Shaft RPM: 0 Machinery Load

Draft Fwd: 6.4 m Draft Aft: 8 m

Fault Type(s)

Mounting Issues

Findings

- Increased directional (horizontal) vibration level was measured at motor and pump. This is an indication of coupling wear or mounting issues.

Recommendations

- Check coupling condition. - Check motor and pump mounting bolts tightness.

Historical Data

Date Surveyed Rating Fault Type(s)

Page 54: VIBRATION & IR THERMOGRAPHY SURVEY REPORT

FNT at SEA SERVICES Ltd

36 FNT 840.2/02/17/REP/30/07/17

Summary Measurements Table

Boiler Feed Water Circ Pump No1

Location Vibration

Level Units Date Remarks

MNDE – Horizontal 0.6983 g RMS 7/22/2017

MNDE – Horizontal 12.23 mm/s RMS 7/22/2017

MNDE – Vertical 0.5626 g RMS 7/22/2017

MNDE – Vertical 2.192 mm/s RMS 7/22/2017

MDE – Horizontal 0.9585 g RMS 7/22/2017

MDE – Horizontal 9.965 mm/s RMS 7/22/2017

MDE – Vertical 0.9717 g RMS 7/22/2017

MDE – Vertical 4.005 mm/s RMS 7/22/2017

MDE – Axial 0.6893 g RMS 7/22/2017

MDE – Axial 5.047 mm/s RMS 7/22/2017

Pump casing – Horizontal 1.707 g RMS 7/22/2017

Pump casing – Horizontal 11.37 mm/s RMS 7/22/2017

Pump casing – Vertical 1.023 g RMS 7/22/2017

Pump casing – Vertical 5.722 mm/s RMS 7/22/2017

Page 55: VIBRATION & IR THERMOGRAPHY SURVEY REPORT

FNT at SEA SERVICES Ltd

37 FNT 840.2/02/17/REP/30/07/17

Vibration Analysis Plots

Motor n.d.e vibration Spectrum in horizontal direction

Pump vibration Spectrum in horizontal direction


Recommended