+ All Categories
Home > Documents > Vickers and Kno Op 402 Mvd

Vickers and Kno Op 402 Mvd

Date post: 30-Oct-2014
Category:
Upload: mohammad-mohsin
View: 43 times
Download: 6 times
Share this document with a friend
2
www.wolpertwilson.com HV0.01 up to HV2, and HK0.01 to HK2 Direct load selection automatically changes in test settings Motorized turret operation, enabling automated test cycle by the push of start button Smooth XY-stage 100x100 mm, travel 25x25 mm, motorized versions available Hardness diagonals, value, statistics and conversions on backlit display Easy-to-use interface in 6 different languages. Solid eyepiece with digital encoder Two optical paths, for eyepiece and ccd-camera Applications • Steels, non-ferrous metals, IC wafer • Thin plastic, metallic foils, plating, coating, surface layers, laminated metals • Effect of heat treatment • Hardness depths of carburized layer and ame hardened layer • Cemented carbide, ceramics, steels, non-ferrous metals • Thin plates, metallic foils, plating, miniature objects • Hardness resulting from welding or deposition The Series 400 Vickers and Knoop testers are versatile, user-friendly, and provide an affordable, reliable solution for accurate Vickers and Knoop hardness scale testing, both for quality assurance or metallurgical research. The 400 Series is available with an automatic turret and comes equipped with crisp optics that have a total magnication of 100x and 400x. The systems feature eight dial selectable test forces ranging from 10 g to 2 kg (see table). For easy sample mounting, models are equipped with a 100 x 100 mm precision XY stage with 25 mm movement in each direction. Wolpert Wilson ® Instruments 402 MVD Microhardness Tester from 10 gf to 2 kgf
Transcript
Page 1: Vickers and Kno Op 402 Mvd

www.wolpertwilson.com

HV0.01 up to HV2, and HK0.01 to HK2 Direct load selection automatically changesin test settings

Motorized turret operation, enabling automated test cycle by the push of start button

Smooth XY-stage 100x100 mm,travel 25x25 mm, motorized versions available

Hardness diagonals, value, statistics andconversions on backlit display

Easy-to-use interface in 6 different languages.

Solid eyepiece with digital encoder

Two optical paths,for eyepiece and ccd-camera

Applications

• Steels, non-ferrous metals, IC wafer • Thin plastic, metallic foils, plating, coating, surface layers, laminated metals • Effect of heat treatment• Hardness depths of carburized layer and fl ame hardened layer

• Cemented carbide, ceramics, steels, non-ferrous metals• Thin plates, metallic foils, plating, miniature objects• Hardness resulting from welding or deposition

The Series 400 Vickers and Knoop testers are versatile, user-friendly, and provide an affordable, reliable solution for accurate Vickers and Knoop hardness scale testing, both for quality assurance or metallurgical research. The 400 Series is available with an automatic turret and comes equipped with crisp optics that have a total magnifi cation of 100x and 400x. The systems feature eight dial selectable test forces ranging from 10 g to 2 kg (see table). For easy sample mounting, models are equipped with a 100 x 100 mm precision XY stage with 25 mm movement in each direction.

Wolpert Wilson® Instruments 402 MVDMicrohardness Tester from 10 gf to 2 kgf

Page 2: Vickers and Kno Op 402 Mvd

Wolpert Wilson Instruments is a registered trademark of Illinois Tool Works Inc. (ITW) Other names, logos, icons and marks identifying Instron products and services referenced herein are trademarks of ITW and may not be used without the prior written permission of ITW. Other product and company names listed are trademarks or trade names of their respective companies. Copyright © 2009 Illinois Tool Works Inc. All rights reserved. All of the specifications shown in this document are subject to change without notice.

Technical Specifi cations

®®

We are Local to You

Wolpert Wilson Instruments is an Instron® ITW Company

POD_402MVD series_rev1_0109

Wolpert Wilson® Instruments 402 MVDMicrohardness Tester from 10 gf to 2 kgf

Hardness Scales Vickers & Knoop

Test Load 10 - 25 - 50 - 100 - 200 - 300 - 500 - 1000 (2000) gf

Test Load Selection Dial

Accuracy Conforms to EN-ISO 6507, ASTM E384 & E92 and JIS

Load Control Automatic (loading/dwell/unloading)

Load Duration (Dwell time) 5 to 99 seconds

Turret Automatic

Eyepiece Magnifi cation 10x

Digital Encoder Resolution 0.1μm

Objectives 10x, 40x

Total Magnifi cation 400x (for measurement)

Measuring Range 100x (for observation), 200μm

Optical Path 2-way switchable : eyepiece/camera

Light Filter Green and Blue

Light Source Halogen lamp

Display Length of diagonal, hardness converted value, test force

Hardness Value 5-digit

Diagonal Length 4-digit (D1, D2)

Data output Built-in printer, RS232

Statistics Number, Average, Standard deviation, Range

Conversion Brinell, Rockwell, Superfi cial Rockwell, Tensile Strength

Maximum Specimen Height 210 mm (2.55”)

Depth from the Centerline 85 mm (2.55”)

XY Stage Dimensions 100 x 100 mm

XY Stage Travel Range 25 x 25 mm

Minimum Reading 0.01 mm

Operating Temperature Range: 10 to 38°C (50 to 100°F)

Humidity 10% to 90% non-condensing

Dimensions 513 mm (20,2”) x 320 mm (12,6”) x 470 mm (18.5”)

Weight 36 kg (79.4lbs)

Power Supply 110-220V AC, 60/50Hz

Accessories

• XY-stage with digital micrometers• Hardness reference blocks HV/HK with NVLAP, UKAS or DKD certifi cate• Precision vices, V-blocks and special clamps• Minuteman ELT™ PC-controlled Camera system• Motorized XY-stages

Please ask for a full accessories catalog

Wolpert Wilson Instruments offer a wide range ofreference blocks. All certifi ed reference blocks will be issued with a certifi cate traceable to internationally recognized standards, such as UKAS, DKD or ASTM.

We also offer certifi ed indenters.

Test Blocks and Indenters

Wolpert Wilson InstrumentsEurope • [email protected][email protected]