Date post: | 04-Jun-2018 |
Category: |
Documents |
Upload: | carlos-lehman |
View: | 218 times |
Download: | 0 times |
of 19
8/13/2019 Vicot Solar Air Conditioning System
1/19
8/13/2019 Vicot Solar Air Conditioning System
2/19
Aboutus
Being founded in November 18th 2005 with a registered capital of RMB
30.67million, Shandong Vicot Air Conditioning Co., Ltd is a hightech corporation
specializedinR&D,production,salesandserviceofrenewableenergyproducts.
OurproductionbaselocatesinSolarCity,Dezhou,China,itstotalinvestment
is of RMB 338 million and covers an area of 150,000 with modern workshops
andofficebuildingsofmorethan80,000.Manufacturingfacilitiesandcapability
asfollowings:14electricalACproductionlineswithannualyieldof100,000electrical
AC units; 7 gasfired AC production lines for assembly and key components with
annualyield
of
10,000
gas
fired
AC
units;
More
than
20
solar
collector
production
equipmentwithannualyieldof200,000 ofcollectors;6vacuumtubeproduction
lineswithannualyieldof100,000piecesoftubes;Annualyieldof10,000standard
setsofsolarairconditioningsystem(20kW/standardset)and500standardsetsof
solarboilersystem(700kW/standardset).
WehaveISO9001:2008,ISO14001:2004,CE,ETL,CCCcertificates:
8/13/2019 Vicot Solar Air Conditioning System
3/19
Contents
Vicotproductlines...1
Roadmaptoenergyfuture..2
Vicotsolarairconditionersystem....3
Vicotsolarcollector.5
Vicotsolarthermalenergyaccumulator..7
Vicotgasfiredorsolarpoweredaircooledammoniawaterabsorptionchiller9
Specification12
8/13/2019 Vicot Solar Air Conditioning System
4/19
Vicotproductlines
A. Solar
energy
driven
1. Solarboiler
2. Solarairconditioner
B. Naturalgas/LPG/LNGdriven
1. Gasfiredabsorptionchiller
C. Electricitydriven
1. Aircooledwaterchiller
2. Watercooledwaterchiller
3. Geothermalheatpump
4. Rooftoppackagedunit
5. Ductedsplitunit
6. Topdischargecondensingunit
7. DXfancoilunit
8. Chilledwaterfancoilunit
9. Airhandlingunit
. .
1
8/13/2019 Vicot Solar Air Conditioning System
5/19
Roadmaptoenergyfuture
. .
Traditional
Heating
Backup
energy
Solarheating
Renewable
SolarEnergy
Absorption
refrigeration
Oil,gas,coal
electricity
Solarboiler
Traditional
cooling
2
8/13/2019 Vicot Solar Air Conditioning System
6/19
Vicotsolarairconditionersystem
Briefintroduction
Vicotsolarairconditioner,aChineseAmericanjointdevelopment.Threeyears
of collaboration and technology transfer have led to remarkable achievements in
solarenergy,scienceandtechnology,yieldingconversionefficienciesforheatingand
coolingof
up
to
85%,
solar
concentrations
27
times
higher
than
ordinary
flat
plate
collectors for water heating. This solar energy technology will truly contribute to
preserving our planet. The GWP
8/13/2019 Vicot Solar Air Conditioning System
7/19
Vicotsolarairconditionersystem
4.NaturalrefrigerantMR717,noharmtoenvironment;
5.220
oCphase
change
molten
salt
material
for
thermal
storage;
6. 3.5 years' payback over conventional electric air conditioner ( in 800W/m2
radiation,3200insolationhours/year);
7.Electricitysavingis417kW.h/m2peryear;
(irradiance:800W/m2,thesunlighthourperyear:3200hours)
8.AnnualCO2emissionreductionis370kg/m2.
(irradiance:800W/m2,thesunlighthourperyear:3200hours)
OperationPID
. .4
8/13/2019 Vicot Solar Air Conditioning System
8/19
Vicotsolarcollector
Briefintroduction:
Vicot solar collector efficiency is higher than 75% at incogitable cost for
ordinary people, the Chinese and American scientists and engineers convert the
expensive space technologywith theirgenius intelligence into an emerging energy
savingelite
for
every
people.
Savingsfigure:
1m2solarcollectorsaves223kgstandardcoalor155m3naturalgas
1m2 solar collector meets the heating demand of construction area up to
20m2
1m2solarcollectorcanhaveannualsteamproductionupto2.89Ton
. .5
8/13/2019 Vicot Solar Air Conditioning System
9/19
Vicotsolarcollector
Features
1.
High
efficiency
>75%,
four
times
of
normal
solar
heater
2.Heattransferoiltemperatureupto350
3.Specialreflectionmirrorforsolarenergy
4.Automaticsunshinetrackingsystem
5.360safetyprotectionsystem
6.Modularstructuredesign
7.Efficienttransportationsimilartoassemblyfurniture
8.Convenientassemblysimilartoassemblyfurniture
9.Designforwithstandingwindofclass10
Solarcollectorcomponents
Concentrationmirror
Concentration mirror is a parabolic mirror coated with
sunlightconcentrationmaterial. Itconcentratesthe low
density sunlight on vacuum tube for producing high
temperature.
Vacuumheatpipe
It's vacuum heat pipe type glass metal heat collection
tube.
Flexibleinstallation
Installation can be made on roof to building, garage or
onground
floor.
Convenienttransportation
Solar collector is modular type design, and can be
shipped in knock down condition, the transportation is
simple and economic, and site assembly is convenient
andflexible.
. .6
8/13/2019 Vicot Solar Air Conditioning System
10/19
Vicotsolarthermalenergyaccumulator
Briefintroduction:
OurChineseandAmericanscientistsandengineershavesolvedtheproblemof
accumulationofmediumhigh temperaturesolarenergyand realized thedreamof
havingasuninnightskywiththeirgeniusintelligence,whichisoneofthebasesfor
largescaleapplicationofsolarenergy.
Features:
1.Highefficientheatexchangedesign
2.Modulardesign
3. Special high temperature thermal storage phase changing material, there are
threeoptionalphasechangingpoints160,220 and250.
4.Highthermalstoragedensity
5.Latentheatandsensibleheatstoragecanbeappliedsimultaneously.
6.Strongthermalstoragecapacity
. .7
8/13/2019 Vicot Solar Air Conditioning System
11/19
Vicotsolarthermalenergyaccumulator
Accumulatorstructure
Thermalstoragecurve
. .8
8/13/2019 Vicot Solar Air Conditioning System
12/19
Vicotgasfiredand/orsolarpoweredaircooledammoniawaterabsorptionchiller
Briefintroduction
Vicot gasfired and/or solar powered aircooled ammoniawater absorption
chiller is a high efficiency for residential and light commercial air conditioning,
basedonthehighlyefficientgeneratorabsorberheatexchanger(GAX)absorption
cycle.
AbsorptionPrinciple
. .9
8/13/2019 Vicot Solar Air Conditioning System
13/19
Vicotgasfiredand/orsolarpoweredaircooledammoniawaterabsorptionchiller
Briefintroduction:
Vicot
gasfired
and/or
solar
powered
air
cooled
ammonia
water
absorption
chiller is a high efficiency for residential and light commercial air conditioning,
basedonthehighlyefficientgeneratorabsorberheatexchanger(GAX)absorption
cycle.
Features:
1PatentedTechnologyforFirstEverContinuouslyVariableSpeedOperation.
2Modulardesignandparallelmultiunitconnectioncanrealize5RT~35RTcapacity.
335TRgroupscanbecentralizedupto175TR.
4IntelligentControlsforLoadMatchingforOptimalEfficiency.
5CanProduceChilledGlycolToTemperaturesof8CforIcemaking.
6Efficientvariablespeedmotorcontroltechnology.
7LowNOxburner,ExtremelyCleanBurning.
8Optionalheatingmoduleforhotwatersupplyin24hours.
9Stableoperationinambienttemperaturefrom20 to55.
10NonToxicCorrosionInhibitorinrefrigerationsystem.
11Thetrueecofriendlyairconditioning.
Performancecurve
0
10000
20000
30000
40000
50000
60000
70000
80000
50 60 70 80 90 100 110 120
OutdoorTemperature
CoolingCapacityBTU/H
PartloadFull load
. .10
8/13/2019 Vicot Solar Air Conditioning System
14/19
Vicotgasfiredorsolarpoweredaircooledammoniawaterabsorptionchiller
Dimension
Gas(1/2")
Water inlet(5/4")Water outlet(5/4")Power
. .11
8/13/2019 Vicot Solar Air Conditioning System
15/19
Vicotgasfiredorsolarpoweredaircooledammoniawaterabsorptionchiller
Screenshotofprototypeoperatingcondition
REFRIGERANT
T=145.9
P=267.7
Y=0.9976
T=94.4
Subcooling=20.2
R:LV_B ETA_H W:LV_B ETA_H
T=45.98
Q=60,567
Flow=115.0
T=54.7
T=245.2
P=69.5
T flue=384.8
WEAK LIQUOR
T=395.8
X=0.0235
AM BIENT=95.8
P gas=14.21
T gas=82.2
Gas Timing = 7 7.7
mmFIRING=85,365
Electrical Power
(W)=834
GAS RATE=86,050
COP =0.7039
CAPACITY =60,567
BETA 23
95 Normal Fire
8/3/2003 8:32 - 8:47
08:32 to 08:47
beta 23-030803.bin 08/03/2 003
COMBUSTION
ANA LYSIS
NOx 9ppm
O2 5.0%
CO 15ppm
CO2 9.0%
ex air 28.0%
eff 98.9%
SYSTEM CHARGE
H2O=17.7 lb
NH3=16.5 lb
NaOH=46.5 g
AG 11 00=46 .5 g
CONTROL
CHIP BCH3726Y
FAN EC23711B
Tbub=36.6Flow (calc)=2.19
[Btu/lb: 460]
T bub=290.6
T=232.
Generator cutout 262.2
. .12
8/13/2019 Vicot Solar Air Conditioning System
16/19
Specification
Model VSAC005A VSAC010A VSAC015A VSAC020A
Item
Aircooled
ammonia
water
absorption
chiller
RT 5 10 15 20
kW 18 36 54 72Coolingcapacity
h 60 0 12 0 18 0 24 0BTU/ ,00 0,00 0,00 0,00
RT 2.5~5 2.5~ 2.5~ 2.5~10 15 20
kW 9~18 9~42 9~54 9~72Capacity regulation
h ~60000 ~120000 ~180000 ~240000range
BTU/ 30000 30000 30000 30000
Refrigeranttype MR717
Waterflowrate m3/h .1 6.2 9.3 12.43
Dimension(L*W*H)1500*914*1632 (1500*914*1632) (1500*914*1632) (1500*914*1632)
mm 2* 3* 4*
Driving
temperature
1
o
C
50
o
C
~220
o
C
Powersupply 220V/1PH/50Hz(pleasecheckwithusfordifferentpowersupply)
Powerinput kW 0.8 1.6 2.4 3.2
Weight kg 485 970 1455 1940
Solarcollector
Collectorarea m 45 90 120 1652
Collectoroutput kW 25 50 75 100
Installationarea m2 90 180 240 330
Weight Kg 1800 3600 4800 6600
Thermalmedia alheattransfMiner eroil
Accumulator
Storagecapacity 105kJ 3.6 7.2 10.8 14.4
Volume m3 1.17 2.34 3.51 4.68
otes:
stconditionsoftheunit
ambienttemperature35oC;
2. mperature7oC;
andhotoilmaybeusedassupplementaryenergy.
N
1.Thete
SolarirradianceQ=1000W/m2,
Chilledwaterinlettemperature12oC,chilledwateroutlette
3.Capacityregulationrangeoftheunitistherangeofitssteplessinverter;
4.Thethermalstoragecapacitycanbecustomized;
5.Inthespecialcircumstances,naturalgas/LPG/LNG
. .13
8/13/2019 Vicot Solar Air Conditioning System
17/19
Specification
Model VSAC025A VSAC030A VSAC035A
Item
Aircooled
ammonia
water
absorption
chiller
RT 25 30 35
kW 90 108 126Coolingcapacity
h 30 0 36 0 42 0BTU/ 0,00 0,00 0,00
RT 2.5~25 2.5~ 2.5~3530
kW 9~90 9~108 9~126Capacity regulation
h ~300000 360000 420000range
BTU/ 30000 30000~ 30000~
Refrigeranttype MR717
Waterflowrate m3/h 15.5 18.6 21.7
Dimension(L*W*H)(1500*914*1632) (1500*914*1632) (1500*914*1632)
mm 5* 6* 7*
Driving
temperature
15
o
C
0
o
C
~220 C
o
Powersupply 220V/1PH/50Hz(Plscheckwithusfordifferentpowersupply)
Powerinput kW 4.0 4.8 5.6
Weight kg 2425 2910 3395
Solarcollector
Collectorarea m 210 240 2852
Collectoroutput kW 125 150 175
Installationarea m2 420 480 570
Weight kg 8400 09600 1140
Thermalmedia alheattransferoiMiner l
Accumulator
Storagecapacity 105kJ 18.0 21.6 25.2
Volume m3 5.85 7.02 8.19
otes:
stconditionsoftheunit
ambienttemperature35oC;
2. mperature7oC;
andhotoilmaybeusedassupplementaryenergy.
N
1.Thete
SolarirradianceQ=1000W/m2,
Chilledwaterinlettemperature12oC,chilledwateroutlette
3.Capacityregulationrangeoftheunitistherangeofitssteplessinverter;
4.Thethermalstoragecapacitycanbecustomized;
5.Inthespecialcircumstances,naturalgas/LPG/LNG
. .14
8/13/2019 Vicot Solar Air Conditioning System
18/19
Specification
Model
Item
VSAC070A VSAC105A VSAC140A VSAC175A
Aircooled
ammonia
water
absorption
chiller
RT 70 105 140 175
kW 252 378 504 630Coolingcapacity
BTU/h 840000 1260000 1680000 2100000
RT 2.5~70 2.5~105 2.5~140 2.5~175
kW 9~252 9~378 9~504 9~630Capacity regulation
rangeBTU/h 30000~840000 30000~1260000 30000~1680000 30000~2100000
Refrigeranttype MR717
Waterflowrate m3/h 43.4 65.1 86.8 108.5
Dimension(L*W*H) mm 14*(1500*914*1632)
21*(1500*914*1632)
28*(1500*914*1632)
35*(1500*914*1632)
Drivingtemperature
o
C
150o
C~220
o
CPowersupply 220V/1PH/50Hz(pleasecheckwithusfordifferentpowersupply)
Powerinput kW 11.2 16.8 22.4 28
Weight kg 6790 10185 13580 16975
Solarcollector
Collectorarea m2 570 840 1125 1410
Collectoroutput kW 350 525 700 875
Installationarea m2 1140 1680 2250 2820
Weight kg 22800 33600 45000 56400
Thermalmedia Mineralheattransferoil
Accumulator
Storage
capacity
10
5
kJ
50.4
75.6
100.8
126
Volume m3 16.38 24.57 32.76 40.95
Notes:
1.Thetestconditionsoftheunit
SolarirradianceQ=1000W/m2,ambienttemperature35
oC;
2.Chilledwaterinlettemperature12oC,chilledwateroutlettemperature7
oC;
3.Capacityregulationrangeoftheunitistherangeofitssteplessinverter;
4.Thethermalstoragecapacitycanbecustomized;
5.Inthespecialcircumstances,naturalgas/LPG/LNGandhotoilmaybeusedassupplementaryenergy.
. .15
8/13/2019 Vicot Solar Air Conditioning System
19/19
VicotSolarairconditionerBreathingtogether,CoEnergysaving
Specialthanks
to:
ChineseAcademyofSciences
BeijingSolarEnergyResearchInstitute
WuhanUniversityofTechnology
FAFCOEnergyStorageDevicesCompany
VicotairconditioningCo.,Ltd.
/Add:HongduRd.Dezhoueconomiczone,Shandong/Postalcode253022/
/Tel:
+86
531
82355568
/Fax+86
531
82357911
/
/Email:[email protected]/
/Http://www.vicot.com.cn /
Nov.2011
The product design is subject to change without prior notice.
mailto:[email protected]:[email protected]