  • 8/13/2019 Vicot Solar Air Conditioning System

    1/19

  • 8/13/2019 Vicot Solar Air Conditioning System

    2/19

    Aboutus

    Being founded in November 18th 2005 with a registered capital of RMB

    30.67million, Shandong Vicot Air Conditioning Co., Ltd is a hightech corporation

    specializedinR&D,production,salesandserviceofrenewableenergyproducts.

    OurproductionbaselocatesinSolarCity,Dezhou,China,itstotalinvestment

    is of RMB 338 million and covers an area of 150,000 with modern workshops

    andofficebuildingsofmorethan80,000.Manufacturingfacilitiesandcapability

    asfollowings:14electricalACproductionlineswithannualyieldof100,000electrical

    AC units; 7 gasfired AC production lines for assembly and key components with

    annualyield

    of

    10,000

    gas

    fired

    AC

    units;

    More

    than

    20

    solar

    collector

    production

    equipmentwithannualyieldof200,000 ofcollectors;6vacuumtubeproduction

    lineswithannualyieldof100,000piecesoftubes;Annualyieldof10,000standard

    setsofsolarairconditioningsystem(20kW/standardset)and500standardsetsof

    solarboilersystem(700kW/standardset).

    WehaveISO9001:2008,ISO14001:2004,CE,ETL,CCCcertificates:

  • 8/13/2019 Vicot Solar Air Conditioning System

    3/19

    Contents

    Vicotproductlines...1

    Roadmaptoenergyfuture..2

    Vicotsolarairconditionersystem....3

    Vicotsolarcollector.5

    Vicotsolarthermalenergyaccumulator..7

    Vicotgasfiredorsolarpoweredaircooledammoniawaterabsorptionchiller9

    Specification12

  • 8/13/2019 Vicot Solar Air Conditioning System

    4/19

    Vicotproductlines

    A. Solar

    energy

    driven

    1. Solarboiler

    2. Solarairconditioner

    B. Naturalgas/LPG/LNGdriven

    1. Gasfiredabsorptionchiller

    C. Electricitydriven

    1. Aircooledwaterchiller

    2. Watercooledwaterchiller

    3. Geothermalheatpump

    4. Rooftoppackagedunit

    5. Ductedsplitunit

    6. Topdischargecondensingunit

    7. DXfancoilunit

    8. Chilledwaterfancoilunit

    9. Airhandlingunit

    . .

    1

  • 8/13/2019 Vicot Solar Air Conditioning System

    5/19

    Roadmaptoenergyfuture

    . .

    Traditional

    Heating

    Backup

    energy

    Solarheating

    Renewable

    SolarEnergy

    Absorption

    refrigeration

    Oil,gas,coal

    electricity

    Solarboiler

    Traditional

    cooling

    2

  • 8/13/2019 Vicot Solar Air Conditioning System

    6/19

    Vicotsolarairconditionersystem

    Briefintroduction

    Vicotsolarairconditioner,aChineseAmericanjointdevelopment.Threeyears

    of collaboration and technology transfer have led to remarkable achievements in

    solarenergy,scienceandtechnology,yieldingconversionefficienciesforheatingand

    coolingof

    up

    to

    85%,

    solar

    concentrations

    27

    times

    higher

    than

    ordinary

    flat

    plate

    collectors for water heating. This solar energy technology will truly contribute to

    preserving our planet. The GWP

  • 8/13/2019 Vicot Solar Air Conditioning System

    7/19

    Vicotsolarairconditionersystem

    4.NaturalrefrigerantMR717,noharmtoenvironment;

    5.220

    oCphase

    change

    molten

    salt

    material

    for

    thermal

    storage;

    6. 3.5 years' payback over conventional electric air conditioner ( in 800W/m2

    radiation,3200insolationhours/year);

    7.Electricitysavingis417kW.h/m2peryear;

    (irradiance:800W/m2,thesunlighthourperyear:3200hours)

    8.AnnualCO2emissionreductionis370kg/m2.

    (irradiance:800W/m2,thesunlighthourperyear:3200hours)

    OperationPID

    . .4

  • 8/13/2019 Vicot Solar Air Conditioning System

    8/19

    Vicotsolarcollector

    Briefintroduction:

    Vicot solar collector efficiency is higher than 75% at incogitable cost for

    ordinary people, the Chinese and American scientists and engineers convert the

    expensive space technologywith theirgenius intelligence into an emerging energy

    savingelite

    for

    every

    people.

    Savingsfigure:

    1m2solarcollectorsaves223kgstandardcoalor155m3naturalgas

    1m2 solar collector meets the heating demand of construction area up to

    20m2

    1m2solarcollectorcanhaveannualsteamproductionupto2.89Ton

    . .5

  • 8/13/2019 Vicot Solar Air Conditioning System

    9/19

    Vicotsolarcollector

    Features

    1.

    High

    efficiency

    >75%,

    four

    times

    of

    normal

    solar

    heater

    2.Heattransferoiltemperatureupto350

    3.Specialreflectionmirrorforsolarenergy

    4.Automaticsunshinetrackingsystem

    5.360safetyprotectionsystem

    6.Modularstructuredesign

    7.Efficienttransportationsimilartoassemblyfurniture

    8.Convenientassemblysimilartoassemblyfurniture

    9.Designforwithstandingwindofclass10

    Solarcollectorcomponents

    Concentrationmirror

    Concentration mirror is a parabolic mirror coated with

    sunlightconcentrationmaterial. Itconcentratesthe low

    density sunlight on vacuum tube for producing high

    temperature.

    Vacuumheatpipe

    It's vacuum heat pipe type glass metal heat collection

    tube.

    Flexibleinstallation

    Installation can be made on roof to building, garage or

    onground

    floor.

    Convenienttransportation

    Solar collector is modular type design, and can be

    shipped in knock down condition, the transportation is

    simple and economic, and site assembly is convenient

    andflexible.

    . .6

  • 8/13/2019 Vicot Solar Air Conditioning System

    10/19

    Vicotsolarthermalenergyaccumulator

    Briefintroduction:

    OurChineseandAmericanscientistsandengineershavesolvedtheproblemof

    accumulationofmediumhigh temperaturesolarenergyand realized thedreamof

    havingasuninnightskywiththeirgeniusintelligence,whichisoneofthebasesfor

    largescaleapplicationofsolarenergy.

    Features:

    1.Highefficientheatexchangedesign

    2.Modulardesign

    3. Special high temperature thermal storage phase changing material, there are

    threeoptionalphasechangingpoints160,220 and250.

    4.Highthermalstoragedensity

    5.Latentheatandsensibleheatstoragecanbeappliedsimultaneously.

    6.Strongthermalstoragecapacity

    . .7

  • 8/13/2019 Vicot Solar Air Conditioning System

    11/19

    Vicotsolarthermalenergyaccumulator

    Accumulatorstructure

    Thermalstoragecurve

    . .8

  • 8/13/2019 Vicot Solar Air Conditioning System

    12/19

    Vicotgasfiredand/orsolarpoweredaircooledammoniawaterabsorptionchiller

    Briefintroduction

    Vicot gasfired and/or solar powered aircooled ammoniawater absorption

    chiller is a high efficiency for residential and light commercial air conditioning,

    basedonthehighlyefficientgeneratorabsorberheatexchanger(GAX)absorption

    cycle.

    AbsorptionPrinciple

    . .9

  • 8/13/2019 Vicot Solar Air Conditioning System

    13/19

    Vicotgasfiredand/orsolarpoweredaircooledammoniawaterabsorptionchiller

    Briefintroduction:

    Vicot

    gasfired

    and/or

    solar

    powered

    air

    cooled

    ammonia

    water

    absorption

    chiller is a high efficiency for residential and light commercial air conditioning,

    basedonthehighlyefficientgeneratorabsorberheatexchanger(GAX)absorption

    cycle.

    Features:

    1PatentedTechnologyforFirstEverContinuouslyVariableSpeedOperation.

    2Modulardesignandparallelmultiunitconnectioncanrealize5RT~35RTcapacity.

    335TRgroupscanbecentralizedupto175TR.

    4IntelligentControlsforLoadMatchingforOptimalEfficiency.

    5CanProduceChilledGlycolToTemperaturesof8CforIcemaking.

    6Efficientvariablespeedmotorcontroltechnology.

    7LowNOxburner,ExtremelyCleanBurning.

    8Optionalheatingmoduleforhotwatersupplyin24hours.

    9Stableoperationinambienttemperaturefrom20 to55.

    10NonToxicCorrosionInhibitorinrefrigerationsystem.

    11Thetrueecofriendlyairconditioning.

    Performancecurve

    0

    10000

    20000

    30000

    40000

    50000

    60000

    70000

    80000

    50 60 70 80 90 100 110 120

    OutdoorTemperature

    CoolingCapacityBTU/H

    PartloadFull load

    . .10

  • 8/13/2019 Vicot Solar Air Conditioning System

    14/19

    Vicotgasfiredorsolarpoweredaircooledammoniawaterabsorptionchiller

    Dimension

    Gas(1/2")

    Water inlet(5/4")Water outlet(5/4")Power

    . .11

  • 8/13/2019 Vicot Solar Air Conditioning System

    15/19

    Vicotgasfiredorsolarpoweredaircooledammoniawaterabsorptionchiller

    Screenshotofprototypeoperatingcondition

    REFRIGERANT

    T=145.9

    P=267.7

    Y=0.9976

    T=94.4

    Subcooling=20.2

    R:LV_B ETA_H W:LV_B ETA_H

    T=45.98

    Q=60,567

    Flow=115.0

    T=54.7

    T=245.2

    P=69.5

    T flue=384.8

    WEAK LIQUOR

    T=395.8

    X=0.0235

    AM BIENT=95.8

    P gas=14.21

    T gas=82.2

    Gas Timing = 7 7.7

    mmFIRING=85,365

    Electrical Power

    (W)=834

    GAS RATE=86,050

    COP =0.7039

    CAPACITY =60,567

    BETA 23

    95 Normal Fire

    8/3/2003 8:32 - 8:47

    08:32 to 08:47

    beta 23-030803.bin 08/03/2 003

    COMBUSTION

    ANA LYSIS

    NOx 9ppm

    O2 5.0%

    CO 15ppm

    CO2 9.0%

    ex air 28.0%

    eff 98.9%

    SYSTEM CHARGE

    H2O=17.7 lb

    NH3=16.5 lb

    NaOH=46.5 g

    AG 11 00=46 .5 g

    CONTROL

    CHIP BCH3726Y

    FAN EC23711B

    Tbub=36.6Flow (calc)=2.19

    [Btu/lb: 460]

    T bub=290.6

    T=232.

    Generator cutout 262.2

    . .12

  • 8/13/2019 Vicot Solar Air Conditioning System

    16/19

    Specification

    Model VSAC005A VSAC010A VSAC015A VSAC020A

    Item

    Aircooled

    ammonia

    water

    absorption

    chiller

    RT 5 10 15 20

    kW 18 36 54 72Coolingcapacity

    h 60 0 12 0 18 0 24 0BTU/ ,00 0,00 0,00 0,00

    RT 2.5~5 2.5~ 2.5~ 2.5~10 15 20

    kW 9~18 9~42 9~54 9~72Capacity regulation

    h ~60000 ~120000 ~180000 ~240000range

    BTU/ 30000 30000 30000 30000

    Refrigeranttype MR717

    Waterflowrate m3/h .1 6.2 9.3 12.43

    Dimension(L*W*H)1500*914*1632 (1500*914*1632) (1500*914*1632) (1500*914*1632)

    mm 2* 3* 4*

    Driving

    temperature

    1

    o

    C

    50

    o

    C

    ~220

    o

    C

    Powersupply 220V/1PH/50Hz(pleasecheckwithusfordifferentpowersupply)

    Powerinput kW 0.8 1.6 2.4 3.2

    Weight kg 485 970 1455 1940

    Solarcollector

    Collectorarea m 45 90 120 1652

    Collectoroutput kW 25 50 75 100

    Installationarea m2 90 180 240 330

    Weight Kg 1800 3600 4800 6600

    Thermalmedia alheattransfMiner eroil

    Accumulator

    Storagecapacity 105kJ 3.6 7.2 10.8 14.4

    Volume m3 1.17 2.34 3.51 4.68

    otes:

    stconditionsoftheunit

    ambienttemperature35oC;

    2. mperature7oC;

    andhotoilmaybeusedassupplementaryenergy.

    N

    1.Thete

    SolarirradianceQ=1000W/m2,

    Chilledwaterinlettemperature12oC,chilledwateroutlette

    3.Capacityregulationrangeoftheunitistherangeofitssteplessinverter;

    4.Thethermalstoragecapacitycanbecustomized;

    5.Inthespecialcircumstances,naturalgas/LPG/LNG

    . .13

  • 8/13/2019 Vicot Solar Air Conditioning System

    17/19

    Specification

    Model VSAC025A VSAC030A VSAC035A

    Item

    Aircooled

    ammonia

    water

    absorption

    chiller

    RT 25 30 35

    kW 90 108 126Coolingcapacity

    h 30 0 36 0 42 0BTU/ 0,00 0,00 0,00

    RT 2.5~25 2.5~ 2.5~3530

    kW 9~90 9~108 9~126Capacity regulation

    h ~300000 360000 420000range

    BTU/ 30000 30000~ 30000~

    Refrigeranttype MR717

    Waterflowrate m3/h 15.5 18.6 21.7

    Dimension(L*W*H)(1500*914*1632) (1500*914*1632) (1500*914*1632)

    mm 5* 6* 7*

    Driving

    temperature

    15

    o

    C

    0

    o

    C

    ~220 C

    o

    Powersupply 220V/1PH/50Hz(Plscheckwithusfordifferentpowersupply)

    Powerinput kW 4.0 4.8 5.6

    Weight kg 2425 2910 3395

    Solarcollector

    Collectorarea m 210 240 2852

    Collectoroutput kW 125 150 175

    Installationarea m2 420 480 570

    Weight kg 8400 09600 1140

    Thermalmedia alheattransferoiMiner l

    Accumulator

    Storagecapacity 105kJ 18.0 21.6 25.2

    Volume m3 5.85 7.02 8.19

    otes:

    stconditionsoftheunit

    ambienttemperature35oC;

    2. mperature7oC;

    andhotoilmaybeusedassupplementaryenergy.

    N

    1.Thete

    SolarirradianceQ=1000W/m2,

    Chilledwaterinlettemperature12oC,chilledwateroutlette

    3.Capacityregulationrangeoftheunitistherangeofitssteplessinverter;

    4.Thethermalstoragecapacitycanbecustomized;

    5.Inthespecialcircumstances,naturalgas/LPG/LNG

    . .14

  • 8/13/2019 Vicot Solar Air Conditioning System

    18/19

    Specification

    Model

    Item

    VSAC070A VSAC105A VSAC140A VSAC175A

    Aircooled

    ammonia

    water

    absorption

    chiller

    RT 70 105 140 175

    kW 252 378 504 630Coolingcapacity

    BTU/h 840000 1260000 1680000 2100000

    RT 2.5~70 2.5~105 2.5~140 2.5~175

    kW 9~252 9~378 9~504 9~630Capacity regulation

    rangeBTU/h 30000~840000 30000~1260000 30000~1680000 30000~2100000

    Refrigeranttype MR717

    Waterflowrate m3/h 43.4 65.1 86.8 108.5

    Dimension(L*W*H) mm 14*(1500*914*1632)

    21*(1500*914*1632)

    28*(1500*914*1632)

    35*(1500*914*1632)

    Drivingtemperature

    o

    C

    150o

    C~220

    o

    CPowersupply 220V/1PH/50Hz(pleasecheckwithusfordifferentpowersupply)

    Powerinput kW 11.2 16.8 22.4 28

    Weight kg 6790 10185 13580 16975

    Solarcollector

    Collectorarea m2 570 840 1125 1410

    Collectoroutput kW 350 525 700 875

    Installationarea m2 1140 1680 2250 2820

    Weight kg 22800 33600 45000 56400

    Thermalmedia Mineralheattransferoil

    Accumulator

    Storage

    capacity

    10

    5

    kJ

    50.4

    75.6

    100.8

    126

    Volume m3 16.38 24.57 32.76 40.95

    Notes:

    1.Thetestconditionsoftheunit

    SolarirradianceQ=1000W/m2,ambienttemperature35

    oC;

    2.Chilledwaterinlettemperature12oC,chilledwateroutlettemperature7

    oC;

    3.Capacityregulationrangeoftheunitistherangeofitssteplessinverter;

    4.Thethermalstoragecapacitycanbecustomized;

    5.Inthespecialcircumstances,naturalgas/LPG/LNGandhotoilmaybeusedassupplementaryenergy.

    . .15

  • 8/13/2019 Vicot Solar Air Conditioning System

    19/19

    VicotSolarairconditionerBreathingtogether,CoEnergysaving

    Specialthanks

    to:

    ChineseAcademyofSciences

    BeijingSolarEnergyResearchInstitute

    WuhanUniversityofTechnology

    FAFCOEnergyStorageDevicesCompany

    VicotairconditioningCo.,Ltd.

    /Add:HongduRd.Dezhoueconomiczone,Shandong/Postalcode253022/

    /Tel:

    +86

    531

    82355568

    /Fax+86

    531

    82357911

    /

    /Email:[email protected]/

    /Http://www.vicot.com.cn /

    Nov.2011

    The product design is subject to change without prior notice.