Page 1: Viessmann Vitotrol 300 Remote Control

Operating Instructions

Vitotrol 300

Remote control for one heating circuit

Part No. 7133 382

Vitotrol 300

Certified as a component part

of Viessmann boilers only

Ple

ase

file

inS

ervi

ceB

ind

er

5167 505 01/01

Page 2: Viessmann Vitotrol 300 Remote Control

Safety instructions

2

Safety Instructions

Safety, Installation and Warranty Requirements

Please ensure that these instructions are read and understood before commencing installation and operation. Failure to comply with

the instructions listed below and details printed in these instructions can cause product/property damage, severe personal injury,

and/or loss of life. Ensure all requirements below are understood and fulfilled (including detailed information found in manual

subsections).

� Licensed professional heating

contractor

The installation, adjustment, service,

and maintenance of this equipment

must be performed by a licensed

professional heating contractor.� Please see sections

entitled “Safety” and

“Important Regulatory and

Installation Requirements”.

� Product documentation

Read all applicable documentation

before commencing installation. Store

documentation near boiler in a readily

accessible location for reference in the

future by service personnel.� For a listing of applicable

literature, please see

section entitled “Important

Regulatory and Installation

Requirements”.

� Advice to owner

Once the installation work is complete,

the heating contractor must familiarize

the system operator/ultimate owner

with all equipment, as well as safety

precautions/requirements, shut-down

procedure, and the need for professional

service annually before the heating

season begins.

Warranty

Information contained in this and related

product documentation must be read

and followed. Failure to do so renders

warranty null and void.

Safety Terminology

The following terms could appear in these instructions to bring attention to the presence of potential hazards or important product

information. Please heed the advice given!

Helpful hints for installation, operation or

maintenance which pertain to the product.

5167

505

5167

505

Indicates an imminently hazardous

situation which, if not avoided, will

result in death, serious injury or

substantial product/property damage.

DANGERIndicates an imminently hazardous

situation which, if not avoided, could

result in death, serious injury or

substantial product/property damage.

WARNINGIndicates an imminently hazardous

situation which, if not avoided, may

result in minor injury or product/property

damage.

CAUTION

IMPORTANT

Page 3: Viessmann Vitotrol 300 Remote Control

3

Page

Safety Instructions Safety Instructions 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

What You Should Know Inform Yourself

About these instructions 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Basic heating technology know-how 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Overview of operating and display elements 6. . . . . . . . . . . . . . . . . .

Quick Reference On the Spot Operation

Your remote control is preset ... 7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Altering date and time 7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Language selection 8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Selecting your operating mode (summer, winter) 9. . . . . . . . . . .

Altering room temperature 10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Using Viessmann Comfort Functions

Setting the party mode 11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Activating the energy saving mode 11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Operating Instructions Space Heating Adjustments

Accessing/Altering the time program for

space heating 12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Domestic Hot Water Production Adjustments

Accessing/Altering the time program for domestic hot

water production 14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Altering domestic hot water temperature 17. . . . . . . . . . . . . . . . . . . . . . . .

Altering the time program for the DHW recirc. pump 18

When you go on holidays ...

Setting the energy saving mode for your holiday

period 20

Other Adjustments

Accessing temperatures and the operating status 21. . . . . . . .

Altering factory default setting 21. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Appendix What to Do, If...

Diagnosis and corrective action 22. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

How to Save Energy 24. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5167

505

Page 4: Viessmann Vitotrol 300 Remote Control

4

About These Instructions

The following symbols and flag words could be utilized in these

instructions:

Indicates an imminently hazardous

situation which, if not avoided, could

result in death, serious injury or

substantial product / property

damage.

Indicates an imminently hazardous

situation which, if not avoided, may

result in minor injury or product /

property damage.

Helpful hints for installation, operation

or maintenance which pertain to the

product.

This symbol indicates that additional,

pertinent information is to be found in

column three.

This symbol indicates that other

instructions must be referenced.

5167

505

Warnings draw your attention to the

presence of potential hazards or

important product information.

WARNING

Cautions draw your attention to the

presence of potential hazards or

important product information.

CAUTION

IMPORTANT

Page 5: Viessmann Vitotrol 300 Remote Control

Zuerst informieren

5

Basic Heating Technology Know-How

With the Vitotrol remote control the following adjustments can be made:

� “normal room temperature“

� “reduced room temperature“

� domestic hot water temperature

� operating and holiday mode

� heating cycles for space heating, domestic hot water production and the DHW

recirculation pump (if applicable)

� date and time

Except for “normal room temperature” adjustments, all adjustments are transferred

from the Vitotrol remote control to the Vitotronic control unit and vice versa.

Your latest adjustments are effective for your heating circuit.

For the adjustment of the domestic hot water temperature, your heating contractor

can alter codings accordingly - please contact your heating contractor.

The timer of the remote control will automatically switch between “normal room

temperature” and “reduced room temperature” at the preselected times.

1. Normal room temperature

for a comfortably warm living

environment (e.g. 68 ºF / 20 ºC).

2. Reduced room temperature

at nighttime or for the times you

spend away from home. To save

energy this room temperature is set

lower than the “normal room

temperature”.

At the time of delivery “frost

protection” is set to 37 ºF / 3 ºC.

You can select the time and duration of

the room temperature on your

programming unit.

The desired room temperature can be

selected for both “normal room

temperature” and for “reduced room

temperature”.

The timer of the remote control activates and deactivates domestic hot water

production at selected times (only for boiler with domestic hot water tank).

1. Domestic hot water production takes

place when you are at home and

require domestic hot water for your

everyday use (e.g. showering).

2. Domestic hot water production does

not take place

e.g. at nighttime

You can select the time and duration of

the room temperature on your

programming unit.

Desired temperature for domestic hot

water is adjustable up to 140 ºF / 60 ºC.

The domestic hot water recirculation

pump (if applicable) ensures short-term

availability of domestic hot water at

different draw-down locations.

5167

505

IMPORTANT

IMPORTANT

Page 6: Viessmann Vitotrol 300 Remote Control

Zuerst informieren

6

Overview of Operating and Display Elements (with Flip-Down Cover Open)

Heating cycle space heating

Heating cycle DHW production

Heating cycle DHW recirculation pump

Holiday program

Display window(Default setting: time)

Setpoint dial for “normal roomtemperature”

Temperature adjustment

Information

Operating mode selector buttons

Economy mode

Party mode

To confirm

Default setting

DHW temperature

Time/Date

Reduced room temperature

Contrast

Open cover of remote control and press

, at the same time press or to

adjust the contrast.

Illumination of the display window

If the supplied batteries have been

inserted, illumination is activated after

pressing any given button and

deactivated approx. 30 seconds after

your last operation.

Factory default setting

When altered values must be reset to

the factory default setting.

Take note that all values are reset to

the factory default setting.

Flashing values in the display window

indicate that alterations can be made.

If certain adjustments cannot be made at

your remote control, e.g. due to coding

settings by your heating contractor, your

display window will show “without

function”.

5167

505

IMPORTANT

Page 7: Viessmann Vitotrol 300 Remote Control

Sofort bedienen

7

Your Remote Control is Preset ...

The remote control is factory preset to standard operation.

You can alter the factory default setting according to your preferences.

Operating mode

The operating mode is set to “Heating

and Domestic Hot Water”, i.e. space

heating and domestic hot water heating

takes place according to the heating

cycle.

Heating cycles

Space heating with normal room

temperature takes place between 06:00

and 22:00 hrs, domestic hot water

heating (if DHW tank installed) takes

place between 05:30 and 22:00 hrs.

Frost protection takes place between

22:00 and 06:00 hrs (37 ºF / 3 ºC).

5167

505

Page 8: Viessmann Vitotrol 300 Remote Control

Weitere Einstellungen

8

Altering Date and Time

Time and date are factory preset and can be altered manually.

Time

Date

Thu

1. Open flip-down cover of remote

control.

2. for “Time”.

3. / for entering the time.

4. to confirm;

date is displayed.

5. / for entering the date.

6. to confirm.

7. Close flip-down cover of remote

control.

Language Selection

“English” is factory preset as the operating language. You may choose the language

of your preference.

Outside Temp.

i ºC

English

i

1. Open flip-down cover of remote

control.

2. to scan;

outside temperature is

displayed.

3. until desired language

appears.

4. to confirm;

display now indicates the

time.

5. Close flip-down cover of remote

control.

5167

505

Page 9: Viessmann Vitotrol 300 Remote Control

Sofort bedienen

9

Selecting Your Operating Mode (Summer, Winter)

Select one of the operating modes according to your personal preference.

After activating the corresponding button the indicator light will appear; the

selected operating mode will appear in the display window for a short period of

time.

Space heating and domestic hot water

production

� Space heating with alternating normal

and reduced room temperature

according to the set heating cycle

� Domestic hot water production (if

DHW tank installed) and DHW

recirculation pump (if installed)

according to set DHW cycle.

� Frost protection of the heating circuit

Domestic hot water production only

� no space heating,

� domestic hot water heating (if DHW

tank installed) and DHW recirculation

pump (if installed) according to set

DHW cycle.

� Frost protection of the heating circuit

Shut-off operation

� no space heating

� no DHW production

� Frost protection of the heating circuit

e.g. in the winter and for transitional

periods

e.g. in the summer

For heating systems without DHW tank

the display will show “Without Function”

after pressing this button.

All recirculation pumps are activated every

24 hours to avoid seizure.

5167

505

IMPORTANT

IMPORTANT

Page 10: Viessmann Vitotrol 300 Remote Control

Sofort bedienen

10

Altering Room Temperature

In the operating mode “Space Heating and Domestic Hot Water” space heating

takes place with alternating “normal room temperature” and “reduced room

temperature” according to the set heating cycle.

The desired room temperature can be set the following way:

Altering “normal room temperature”

Normal Room Temp.

ºC

Factory default setting:

68 ºF / 20 ºC from 06:00 to 22:00 hrs.

“Normal room temperature“ is

adjustable between 50 and 86 ºF /

10 and 30 ºC.

Adjust the desired temperature at

dial “ “. The temperature appears in

the display window.

Example

For a comfortably warm living

environment

Altering “reduced room temperature”

Frost Protection

ºC

Reduced Room Temp.

ºC

Factory default setting:

Frost protection 37 ºF / 3 ºC

from 22:00 to 06:00 hrs.

”Reduced room temperature” is

adjustable between 37 and 99 ºF /

3 and 37 ºC.

1. Open flip-down cover of remote

control.

2. Press ; the display shown on the

left will appear.

3. Select desired temperature by

activating or .

4. To confirm press ; the

temperature will stop flashing and is

saved.

5. Close cover of remote control.

Example

At nighttime or when away from

home

5167

505

Page 11: Viessmann Vitotrol 300 Remote Control

Komfortfunktionen nutzen

11

Setting the Party Mode

Select the party mode if you require space heating and domestic hot water to beindependent of a selected operating mode and heating cycle and for a short periodof time.During the party mode your living area is heated at the selected “normal roomtemperature” (see “Altering Room Temperature”).You can adjust room temperature (party temperature) according to your personalpreference.One-time domestic hot water production outside the preset heating cycles (see“Accessing/Altering Heating Cycle for Domestic Hot Water Production”) can beactivated by pressing the button twice with two to three seconds in between.

Activating the party mode

Party Mode

ºC

Press , button will be illuminated andwill remain illuminated during the partymode.The icon for the party mode will appearin the display window and the presetparty temperature will flash.

ExampleIf you have guests and require spaceheating and domestic hot waterlonger than usual without having toalter the set heating cycle.

Altering room temperature (party temperature)

1. Open flip-down cover of remotecontrol.

2. Press , the temperature preset atdial “ ” will flash.

3. Select desired temperature bypressing or .

4. To confirm press ; thetemperature shown stops flashingand is saved.

5. Close cover of remote control.

End party mode� The party mode will end with the nextautomatic switching to space heatingwith “normal room temperature”.

� If you would like to end the partymode prematurely, press ; thebutton will no longer be illuminated.

Activating the Energy Saving Mode

The energy saving mode is only available in the “ “ operating mode.Select the energy saving mode if you require short-term and economical spaceheating. In the energy saving mode the preset room temperature is automaticallylowered.

Energy Saving Mode

Activating the energy saving modePress ; the button will be illuminatedand will remain illuminated during theenergy saving mode.The icon for the energy saving modewill appear in the display window for ashort period of time.

Deactivating the energy saving mode� The energy saving mode will endautomatically with the next automaticswitching to space heating with“reduced room temperature”.

� If you would like to end the energysaving mode prematurely, pressagain; the button will no longer beilluminated.

ExampleFor the times you do not spend athome.

5167

505

Page 12: Viessmann Vitotrol 300 Remote Control

12

Accessing/Altering the Time Program for Space Heating

The time program consists of four heating cycles. In the factory default setting,

heating cycle 1 is set for every day of the week from 06:00 to 22:00 hrs., which

means that during this time period space heating takes place according to the

selected “normal room temperature”.

The following options are available to you to set the heating cycles to your liking:

� By selecting the corresponding heating cycle, space heating can alternate up to

four times a day between “normal room temperature” and “reduced room

temperature”.

� You can select the same heating cycle or individual heating cycles for each day

of the week.

When setting the heating phases please pay attention to the reaction time of your

heating system. Please select beginning and end of each cycle accordingly.

Setting the same heating cycles for each day of the week

Time Prog. Heating

1---7

1

1---7

11.Open flip-down cover of the remote

control

12. for “Time Prog. Heating”,

wait until display on the

left appears.

13. for “Heating Cycle 1”

14. for “Heating Cycle 1 On”.

15. / for setting the start of

Cycle 1

16. to confirm;

the display switches to

“Heating Cycle 1 Off“.

17. / for setting the end

of Cycle 1.

18. to confirm;

the display changes to

“Heating Cycle 2 On“.

19. For setting starting and ending

times for Cycles 2 to 4 proceed as

described in steps 5 to 8.

10.Close flip-down cover of the control

unit.

Accessing heating cycles

Proceed as described above with the

exception of pressing buttons and

.

Overview of heating cycles

1. Open flip-down cover of the control

unit.

2. Press both and ; the selectedcycles are shown on a time line.

3. Close cover of control unit.

If you would like to terminate the

heating cycle settings prematurely,

press again.

If you would like to skip a heating

cycle, press .

Once the last setting is confirmed

with the display will show the

current time.

5167

505

Page 13: Viessmann Vitotrol 300 Remote Control

13

Accessing/Altering the Time Program for Space Heating (continued)

Setting individual heating cycles each day of the week

Time Prog. Heating1

1---7

Time Prog. Heating

Mo

1

Mo

11. Open flip-down cover of control

unit.

12. for “Time Prog. Heating“,

wait until display shown on

the left appears.

13. / for selecting the day of the

week when switching

should take place.

14. for “Heating Cycle 1”.

15. for “Heating Cycle 1 On”.

16. / for entering the start of

heating cycle.

17. to confirm;

the display switches to

“Heating Cycle 1 Off”.

18. / for entering the end of the

heating cycle.

19. to confirm;

the display changes to

“Heating Cycle 2 On”.

10. For setting starting and ending

times for Cycles 2 to 4 proceed as

described in steps 6 to 10.

11.Close flip-down cover of remote

control.

Accessing heating cycles

Proceed as described above with the

exception of pressing buttons and

.

Overview of heating cycles

1. Open flip-down cover of remote

control.

2. Press and simultaneously;

the selected cycles for the given day

are shown on a time line.

3. Close flip-down cover of remote

control.

If you would like to terminate the

heating cycle settings prematurely, press

again.

If you would like to skip a heating

cycle, press .

Once the last setting is confirmed

with the display will show thecurrent time.

5167

505

Page 14: Viessmann Vitotrol 300 Remote Control

14

Altering/Accessing the Time Program for Domestic Hot Water Production

The time program consists of four heating cycles. In the factory default settingcycle 1 is set for every day of the week from 05:30 to 22:00 hrs, which meansthat during this time period domestic hot water production takes place.The automatic mode is also preselected, which means that domestic hot waterheating takes place simultaneously to the time program for space heating, withstarting point 30 min. prior to the set time program for space heating.The following options are available to you to set the heating cycles to your liking:� By selecting the corresponding heating cycle, domestic hot water heating can beactivated and deactivated up to four times a day.

� You can select the same heating cycle or individual cycles for each day of theweek.

If you require domestic hot water production on a one-time basis and outside of theprogrammed heating cycles, e.g. after 22:00 hrs, press (see section “Setting theParty Mode”) twice with approx. 2 to 3 seconds in between.

Setting the same heating cycles for each day of the week

Automatic?

Time Prog. DHWTime

1---7

1. Open flip-down cover of remotecontrol.

2. for time program “TimeProg. DHW“, wait untildisplay shown on the leftappears.

3. for “Individual?”.

4. to confirm.

5. for “DHW Heating Cycle1”.

6. for “DHW Heating Cycle 1On”.

7. / for entering the start ofCycle 1.

8. to confirm;display switches to “DHWHeating Cycle 1 Off”.

9. / for entering the end ofCycle 1.

10. to confirm;display switches to “DHWHeating Cycle 1 On”.

11. For setting starting and endingtimes for Cycles 2 to 4 proceed asdescribed in steps 5 to 10.

12.Close flip-down cover of remotecontrol.

If you would like to terminate theheating cycle settings prematurely, press

again

If you would like to skip a heatingcycle, press .

Once the last setting is confirmedwith the display will show thecurrent time.

5167

505

Page 15: Viessmann Vitotrol 300 Remote Control

15

Altering/Accessing the Time Program for DHW Production (continued)

1

1---7

Accessing Heating Cycles

Proceed as described on previous page,

with the exception of pressing buttons

and .

Overview of heating cycles

1. Open flip-down cover of remote

control.

2. Press and simultaneously,

the selected cycles are shown on a

time line.

3. Close flip-down cover of remotecontrol.

5167

505

Page 16: Viessmann Vitotrol 300 Remote Control

16

Altering/Accessing the Time Program for DHW Production (continued)

Setting individual heating cycles each day of the week

Automatic?

1Time Prog. DHW

1---7

MTime Prog. DHW

Mo

1. Open flip-down cover of remote

control.

2. for “Time Program DHW“,

wait until display shown on

the left appears.

3. for “Individual?”.

4. to confirm.

5. / for selecting the day of the

week when switching

should take place.

6. for “DHW Heating Cycle

1”.

7. for “DHW Heating Cycle 1

On”

8. / for entering the start of

Cycle 1.

9. to confirm;

the display will switch to

“DHW Heating Cycle 1

Off”.

10. / for entering the end of

Cycle 1.

11. to confirm;

the display switches to

“DHW Heating Cycle 2

On”.

12. For setting starting and ending

times for Cycles 2 to 4 proceed as

described in steps 6 to 10 .

13.Close flip-down cover of remote

control.

If you would like to terminate the

heating cycle settings prematurely,

press again.

If you would like to skip a heating

cycle, press .

Once the last setting is confirmed

with the display will show the

current time.

5167

505

Page 17: Viessmann Vitotrol 300 Remote Control

Einstellungen Warmwasserbereitung

17

Altering/Accessing the Time Program for DHW Production (continued)

1

Mo

Accessing heating cycles

Proceed as described on previous page,

with the exception of pressing buttons

and .

Overview of heating cycles

1. Open flip-down cover of control unit.

2. Press and simultaneously;

the selected heating cycles for the

given day of the week are shown on

the time line.

3. Close flip-down cover of remote

control.

Altering Domestic Hot Water Temperature

Select the domestic hot water temperature according to your personal preference.

Be sure to reference information in section entitled “Basic Heating Technology

Know-How”.

DHW Temp. Setpoint

ºC

1. Open flip-down cover of remote

control.

2. for DHW temperature;

temperature flashes.

3. / for entering the desired

temperature.

4. to confirm; temperature

stops flashing and

temperature value is saved.

5. Close flip-down cover of remote

control.

5167

505

Page 18: Viessmann Vitotrol 300 Remote Control

Einstellungen Warmwasserbereitung

18

Altering the Time Program for the DHW Recirculation Pump

The time program consists of 4 heating cycles. In the factory default setting, cycle1 is set for every day of the week from 05:30 to 22:00 hrs; during this time periodthe domestic hot water recirculation pump is running.Aside from cycle 1 the automatic mode is preselected, which means that thedomestic hot water recirculation pump is running simultaneously to the DHW timeprogram.The following options are available to you to set the heating cycles to your liking:� By selecting the corresponding heating cycles the domestic hot waterrecirculation pump can be activated and deactivated up to four times a day.

� You can select the same heating cycle or individual cycles for each day of theweek.

The domestic hot water recirculation pump should only be activated when yourequire domestic hot water.

Setting the same heating cycles for each day of the week

Automatic ?

Time Prog. DHW Recirc.Pump1

1---7

1

1---7

1. Open flip-down cover of remotecontrol.

2. for “Time Program DHWRecirculation Pump”,wait until display shown onthe left appears.

3. for “Individual?”

4. to confirm.

5. for “DHW RecirculationPump Cycle 1”.

6. for “DHW RecirculationPump Cycle 1 On”.

7. / for entering the start ofCycle 1.

8. to confirm;display switches to “DHWRecirculation Pump Cycle 1Off”.

9. / for entering the end ofCycle 1.

10. to confirm;display switches to“DHW Recirculation PumpCycle 2”.

11. For setting starting and endingtimes for Cycles 2 to 4 proceed asdescribed in steps 5 to 10 .

12.Close flip-down cover of remotecontrol.

Accessing heating cyclesProceed as describe above, with theexception of pressing buttons and

.

Overview of heating cycles

1. Open flip-down cover of remotecontrol.

2. Press and simultaneously;the selected cycles are shown on atime line.

3. Close cover of remote control.

If you would like to terminate theheating cycle settings prematurely,press again.

If you would like to skip a heatingcycle, press .

Once the last setting is confirmedwith the display will show thecurrent time.

5167

505

Page 19: Viessmann Vitotrol 300 Remote Control

19

Altering the Time Program for the DHW Recirculation Pump (continued)

Setting individual heating cycles each day of the week

Automatic?

Time Prog. DHW Recirc.Pump

1---7

Time Prog. DHW Recirc.Pump

Mo

1

Mo

1. Open flip-down cover of remotecontrol.

2. for “Time Program DHWRecirculation Pump“,wait unit display shown onthe left appears.

3. for “Individual?”.

4. to confirm.

5. / for selecting the day of theweek when switchingshould take place.

6. for “DHW RecirculationPump Cycle 1”.

7. for “DHW RecirculationPump Cycle 1 On”.

8. / for entering the start ofCycle 1.

9. to confirm;the display switches to“DHW Recirculation PumpCycle 1 Off”.

10. / for entering the end ofCycle 1.

11. to confirm;the display switches to“DHW Recirculation PumpCycle 2 On”.

12. For setting starting and endingtimes for Cycles 2 to 4 proceed asdescribed in steps 6 to 10.

13.Close flip-down cover of remotecontrol.

Accessing heating cycles

Proceed as describe above, with theexception of pressing buttons and

.

Overview of heating cycles

1. Open flip-down cover of remotecontrol.

2. Press and simultaneously;the selected cycles for the given dayare shown on a time line.

3. Close flip-down cover of remotecontrol.

If you would like to terminate theheating cycle settings prematurely,press again.

If you would like to skip a heatingcycle, press .

Once the last setting is confirmedwith the display will show thecurrent time.

5167

505

Page 20: Viessmann Vitotrol 300 Remote Control

Wenn Sie in Urlaub fahren ...

20

Setting the Energy Saving Mode for Your Holiday Period

Select one of the following operating modes when you go on holidays and would

like to program your heating system for minimal energy consumption.

Stand-by operation

� no space heating

� no DHW production

� Frost protection of the heating system

E.g. for your summer holiday

The recirculation pump is activated

every 24 hours to prevent seizure.

Holiday program

� no DHW production

� the selected operating mode and time

program activate upon departure and

return.

�with selected operating mode

“ “ space heating takes place at

the preselected “reduced room

temperature” (see “Altering Room

Temperature”).

�with selected operating mode

“ “ or “ “ only frost protection of

the boiler and DHW tank is active

during the holiday mode.

E.g. for indoor plant protection during

your winter getaway and for a heated

living environment upon your return.

Departure Date

Sa

Return Date

Su

1. Open flip-down cover of remote

control.

2. for “Holiday Program”.

3. to confirm

or automatic confirmation

after four seconds; display

shown on the left appears.

4. / for entering the departure

date.

5. to confirm;

the day following the

departure day appears as

the return date.

6. / for entering the return date.

7. to confirm;display now indicates the

boiler water temperature.

8. Close flip-down cover of remote

control.

Once the departure date has passed,

“Holiday Program” and the date appears

in the display.

Once the return date has passed, the

time appears in the display.

Press again, if you would like to

end the holiday mode prematurely.

5167

505

Page 21: Viessmann Vitotrol 300 Remote Control

Weitere Einstellungen

21

Accessing Temperatures and the Operating Status

Depending on the system componentry and performed system adjustments you can

access current temperatures and the operating status:

� Holiday mode (if programmed)

with departure and return date

� Outside temperature

� Supply temperature*1

� Boiler water temperature

� DHW temperature*1

� Return water temperature*1

� Room temperature

� Flue gas temperature*1

� Burner operating hours

� Number of burner starts

� Fuel consumption (if coding was

performed by heating contractor)

� Time

� Date

� Burner On/Off

� Heating circuit pump On/Off

� DHW recirculation pump On/Off

� Circulation Pump On/Off

� Language*1Only if appropriate sensor is installed.

Outside Temperature

i ºC

1. Open flip-down cover of remote

control.

2. to scan;

outside temperature is

displayed.

3. / for further scanning.

4. to end scanning;

display now indicates the

time.

5. Close flip-down cover of remote

control.

Altering Factory Default Setting

Proceed as follows if you would like to change the factory default setting:

Outside Temperature

i ºC

1. press;

outside temperature is

displayed.

2. / to select.

3. to confirm.

Selection:

Outside temperature

Supply temperature*1

Boiler water temperature

DHW temperature*1

Return water temperature*1

Room temperature

Flue gas temperature*1

Time

Date*1Only if appropriate sensor is installed.

5167

505

Page 22: Viessmann Vitotrol 300 Remote Control

Was tun, wenn ...

22

Diagnosis and Corrective Action

If your heating system if working improperly, the fault will be indicated on the

display of the remote control with the flip-down cover closed. By pressing you

can access the fault code yourself and pass it on to your heating contractor

Boiler Temp. Sensor

Acknowledge? Yes

1. Open flip-down cover of remote

control.

2. for fault search.

The fault source is indicated

in clear text and as fault

code.

3. to confirm fault.

4. / for yes or no.

5. to confirm;

display now indicates the

time.

6. Close flip-down cover of remote

control.

Example

Fault indication

Fault number

Sensor designation

Plug designation

Open circuit

or

Short circuit

If fault is not corrected, the fault

message will reappear at 07:00 hrs the

following morning.

What to do, if ... Cause Corrective action

... the rooms are not heated, although

burner is operating.

Only for operation with DHW tank:

Priority of DHW production”

( in display)

Wait until DHW tank is heated.

Operating modes “ “ or “ “ are

selected (corresponding button is lit).

Select “ “ operating mode.

... the room temperature is not satis-

factory at a low outside temperature.

Heating curve adjustment at the con-

trol unit is incorrect.

Check heating curves and, if

necessary, call your heating

contractor for correction.

Remote control is incorrectly

programmed or adjusted.

Check temperatures, time program or

adjustments of the operating mode

and make corrections if necessary.

... rooms are cold during the day and

warm at night.

Remote control is incorrectly

programmed or adjusted.

Check temperatures, time program or

adjustments of the operating mode

and make corrections if necessary.

... “Fault” is flashing in the display

window.

Heating system fault Take note of fault code and contact

your heating contractor.

... “Without Function” appears in the

display window.

The activated button does not have a

designated function, e.g. , when

there is no DHW tank is connected.

5167

505

DFault

Di

ºC

IMPORTANT

Page 23: Viessmann Vitotrol 300 Remote Control

Was tun, wenn ...

23

Diagnosis and Corrective Action (continued)

What to do, if ... Cause Corrective action

... the illumination of the display is

defective.

Empty batteries 1. Unlock remote control from wall-

mount base with a small screw

driver.

2. Remove batteries from rear of

remote control.

3. Change batteries.

Use four AAA batteries.

Insert batteries as illustrated

below.

4.Mount control onto wall-mount

base and snap into place.

Recycling

Batteries / Rechargeable batteries

should not be part of your domestic

waste.

Please ensure that your batteries /

rechargeable batteries are discarded

in the appropriate manner.

IMPORTANT

5167

505

Page 24: Viessmann Vitotrol 300 Remote Control

Tips zum Energiesparen

Viessmann Manufacturing Company Inc.750 McMurray RoadWaterloo, Ontario • N2V 2G5 • CanadaTel. (519) 885-6300 • Fax (519) 885-0887www.viessmann.ca • [email protected]

Viessmann Manufacturing Company (U.S.) Inc.45 Access RoadWarwick, Rhode Island • 02886 • USATel. (401) 732-0667 • Fax (401) 732-0590www.viessmann-us.com • [email protected]

24

How to Save Energy

.... by heating properly.

Aside from using the benefits of a modern heating system, you can increase your

energy savings with your own habits.

The following list may assists you:

� Ventilate properly

� Do not overheat

� Close all window shutters (if installed)

at dusk.

� Adjust thermostatic valves properly.

� Do not obstruct radiators and

thermostatic valves .

�Make use of the adjustment facilities of

the control unit .

� Adjust DHW temperature of the DHW

tank at the control unit .

� Controlled use of domestic hot water

Open window for a short period

completely with all thermostatic

valves closed.

Aim for a room temperature of 68 ºF /

20 ºC, each degree saves up to 6 %

heating costs.

E.g. alternating “normal room

temperature” with “reduced room

temperature”.

A shower typically requires less

energy than a tub bath.

... by performing maintenance regularly.

A regular maintenance check of your heating system by your heating contractor

ensures economical and environmentally friendly heating operation.

.... with effective insulation.

If you would like to make use of other energy-saving possibilities beyond the above

listed, check the insulation:

� of the heating system and DHW

piping.

� of your outside walls and roof.

� between heated and non-heated

rooms.

� of your windows.