INTEGRATION GUIDE Barometer with 9210 Datalogger Series Barometer with 9210 Datalogger Series Prepared by: Sutron ISD October, 2013 Sutron Corporation 22400 Davis Drive
Transcript
Page 1: · Web viewWiring Diagram The wiring shown below describes the most common connection of the barometric pressure sensor using SDI-12. Physically connecting the barometric pressure

INTEGRATION GUIDEBarometer with 9210 Datalogger Series

Barometer with 9210 Datalogger Series

Prepared by:Sutron ISD

October, 2013

Sutron Corporation22400 Davis Drive

Sterling, Virginia 20164TEL: (703) 406-2800FAX: (703) 406-2801

WEB: http://www.sutron.com/

Page 2: · Web viewWiring Diagram The wiring shown below describes the most common connection of the barometric pressure sensor using SDI-12. Physically connecting the barometric pressure

INTEGRATION GUIDEBarometer with 9210 Datalogger Series

ContentsIntroduction.................................................................................................................................................3

Sensor Options........................................................................................................................................3

Part Number............................................................................................................................................3

Mounting Solutions.....................................................................................................................................4

Part Numbers..........................................................................................................................................4

Wiring Diagram............................................................................................................................................5

Common Configurations..............................................................................................................................6

Summary.....................................................................................................................................................7

Page 3: · Web viewWiring Diagram The wiring shown below describes the most common connection of the barometric pressure sensor using SDI-12. Physically connecting the barometric pressure

INTEGRATION GUIDEBarometer with 9210 Datalogger Series

IntroductionThe barometric pressure sensor is one of Sutron’s most commonly used sensors, and is typically used in weather and airport stations. This guide will describe the proper method of connecting the sensor with the 9210 datalogger. This will apply to all dataloggers in the 9210 series. The configuration of the software will be the same for the Xpert datalogger series, but the wiring diagrams will be different. The sensor communicates via the SDI-12 protocol and can interface with any of Sutron’s dataloggers.

Sensor OptionsThere are several types of barometers Sutron manufactures. The differences are the communication protocol used to interface with this sensor, the accuracy rating, as well as the material used to construct the device. The barometers with part numbers 5600-0120-1 and 5600-0120-2 are housed in a lightweight aluminum box, and the 5600-0120-3 versions are housed in tough plastic. Also, the 5600-0120-3 versions come in a variety of accuracy ratings as shown below.

Part Number 5600-0120-1 Pressure Sensor, Barometric, RS-232 and SDI-12 outputs5600-0120-2 Pressure Sensor, Barometric, RS-232, SDI-12 & Analog 0-5VDC outputs5600-0120-3A SDI-12 Barometer, 0.2 mB @ 20°C5600-0120-3B SDI-12 Barometer, 0.3 mB @ 20°C5600-0120-3C SDI-12 Barometer, 0.4 mB @ 20°C

5600-0120-1 and 5600-0120-2 5600-0120-3

Page 4: · Web viewWiring Diagram The wiring shown below describes the most common connection of the barometric pressure sensor using SDI-12. Physically connecting the barometric pressure

INTEGRATION GUIDEBarometer with 9210 Datalogger Series

Mounting SolutionsWhen purchasing a completed station from Sutron, the barometric pressure sensor will come already mounted inside the enclosure. The air pressure in the enclosure is the same as outside the enclosure due to vents that are mounted to the units so the barometer will always be providing accurate measurement. If just the sensor is purchased from Sutron without a whole system, then all that is required to mount the barometer would be 4 screws. If the barometer is being mounted on a metal place, like in a Sutron station, then 4 self tapping screws will be needed.

For stations that require very high accuracy, such as airport weather stations, or for stations that do not have an enclosure vent, the following parts will be required.

Part Numbers5600-0121 Barometer Pressure Port2271-1189 Mounting Feet Replacements

Page 5: · Web viewWiring Diagram The wiring shown below describes the most common connection of the barometric pressure sensor using SDI-12. Physically connecting the barometric pressure

INTEGRATION GUIDEBarometer with 9210 Datalogger Series

Wiring DiagramThe wiring shown below describes the most common connection of the barometric pressure sensor using SDI-12. Physically connecting the barometric pressure sensor to the datalogger requires a three wire conductor. Typically, the sensor will be mounted in the station and pre-wired, but if just the sensor is purchased then view the diagram below.

Page 6: · Web viewWiring Diagram The wiring shown below describes the most common connection of the barometric pressure sensor using SDI-12. Physically connecting the barometric pressure

INTEGRATION GUIDEBarometer with 9210 Datalogger Series

Common ConfigurationsThe 9210 utilizes a graphical setup in order to configure the sensors that are connected. The graphical setup is a series of blocks connected to depict a diagram showing how the data is managed. A typical series of blocks would be an Input, Display, Coms Tag, Measurement, and then a Log block. With this series the sensor would be measured based on the parameters of the input block, then the value would be visible on the front display of the logger, the data tab in the graphical setup would be updated, the measurement interval is defined, and then the value is logged in the log file. Alarms can also be added to the data management series by placing an alarm block before the Coms Tag block. For more detail on how to program a 9210, use the 9210 Operations and Maintenance Manual. The descriptions below will provide a concise description of common measurement setup for the sensor measured every 15 minutes.

Page 7: · Web viewWiring Diagram The wiring shown below describes the most common connection of the barometric pressure sensor using SDI-12. Physically connecting the barometric pressure

INTEGRATION GUIDEBarometer with 9210 Datalogger Series

SummaryThis guide has described the detailed options of the barometric pressure sensor as well as how to connect it to the 9210 datalogger. If you have any questions about this integration guide, or if additional guidance is needed getting started or troubleshooting then please contact Sutron’s Integrated Systems Division at 703-406-2800.