Visual Optimality And Stability Analysis Of 3DCT Scan Positions. Artem Amirkhanov 1,2 Michael Reiter 2 Christoph Heinzl 2 M. Eduard Gröller 1. 1 Institute of Computer Graphics and Algorithms Vienna University of Technology. 2 Upper Austrian University of Applied Sciences - PowerPoint PPT Presentation
Popular Tags:
19
Visual Optimality And Stability Analysis Of 3DCT Scan Positions Artem Amirkhanov 1,2 Michael Reiter 2 Christoph Heinzl 2 M. Eduard Gröller 1 1 Institute of Computer Graphics and Algorithms Vienna University of 2 Upper Austrian University of Applied Sciences Wels Campus, Austria
Transcript
Page 1: Visual Optimality And Stability Analysis Of 3DCT Scan Positions

Visual Optimality And Stability Analysis Of 3DCT Scan Positions

Artem Amirkhanov 1,2

Michael Reiter 2

Christoph Heinzl 2

M. Eduard Gröller 1

1 Institute of Computer Graphicsand Algorithms

Vienna University of Technology

2 Upper Austrian University of Applied Sciences

Wels Campus, Austria

Page 2: Visual Optimality And Stability Analysis Of 3DCT Scan Positions

Artem Amirkhanov 2

Scanning Geometry

X-ray source

Specimen

Detector

Rotary plate

Page 3: Visual Optimality And Stability Analysis Of 3DCT Scan Positions

Placement is crucial forMeasurements accuracy

Iso-surface quality

Requires knowledge, intuitive

Good placement is hard to findFor a complex specimen

For measurement features

Doing several scans is expensive

Artem Amirkhanov 3

Specimen Placement

Page 4: Visual Optimality And Stability Analysis Of 3DCT Scan Positions

CAD model is availableQuality control – from manufacturer

Reverse engineering – preliminary scan

Use a CAD model to estimate a good placement

Visual analysis tool is required forSimulation-based preview

Optimal placement estimation

Tool

Artem Amirkhanov 4

Motivation

Optimal Placement

Page 5: Visual Optimality And Stability Analysis Of 3DCT Scan Positions

Artem Amirkhanov 5

Why Placement is Important?

Beam-hardening artifactsCupping artifacts

Streaks

Bad planar faces artifactsBlurring

Page 6: Visual Optimality And Stability Analysis Of 3DCT Scan Positions

Artem Amirkhanov 6

Good/Bad Placement Example

Bad:

Good:

Page 7: Visual Optimality And Stability Analysis Of 3DCT Scan Positions

Shortest penetration lengths Method: ray casting

Smallest bad planar faces areaMethod: Radon-space analysis

Stable within a certain range of reliabilityMethod: stability widget

Artem Amirkhanov 7

Criteria and Methods

Page 8: Visual Optimality And Stability Analysis Of 3DCT Scan Positions

Artem Amirkhanov 8

Workflow

• Ray casting• Radon-space analysis

Simulation

• Stability analysis• Data exploration and analysis

Visual analysis

Optimal placementOptimal placement

CAD modelCAD model

ParameterspacesParameterspaces

Page 9: Visual Optimality And Stability Analysis Of 3DCT Scan Positions

Artem Amirkhanov 9

Simulation

Set of candidate placements

Placement is defined by the orientation

Orientation is defined by two Euler angles α and β

α

β

Page 10: Visual Optimality And Stability Analysis Of 3DCT Scan Positions

Artem Amirkhanov 10

Ray Casting Simulation

Reflects the scanning setup

Set of projections for every placement

ParametersMaximum penetration length

Average penetration length

Page 11: Visual Optimality And Stability Analysis Of 3DCT Scan Positions

Artem Amirkhanov 11

Radon-Space Analysis

Supporting planes → points in Radon space

Finding bad points in Radon space

ParameterBad faces area percentage

Page 12: Visual Optimality And Stability Analysis Of 3DCT Scan Positions

Artem Amirkhanov 12

Parameters Representation

Best Worst

Parameter value:

Page 13: Visual Optimality And Stability Analysis Of 3DCT Scan Positions

Artem Amirkhanov 13

Stability Widget

Better Same Worse

Parameter value:

Page 14: Visual Optimality And Stability Analysis Of 3DCT Scan Positions

Penetration-length histogramsVisualizing ray subsets .

Color coding bad faces .

Artem Amirkhanov 14

Data Visualization and Exploration

Page 15: Visual Optimality And Stability Analysis Of 3DCT Scan Positions

Artem Amirkhanov 15

Evaluation Using Dimensional Measurements

Two test-part specimens

Measurement featuresRadius

Distance

CALYPSO used to estimate measurement quality

Page 16: Visual Optimality And Stability Analysis Of 3DCT Scan Positions

Complex real world specimen

Best and worst placements

Variance comparison of the iso-surfaces with the CAD model

Artem Amirkhanov 16

Evaluation Using Variance Comparison

Page 17: Visual Optimality And Stability Analysis Of 3DCT Scan Positions

Artem Amirkhanov 17

Evaluation

Bad Placement Good Placement

Position deviation spectrum in [mm] Position deviation spectrum in [mm]

0 -1 -22 1 0 -1 -22 1

Page 18: Visual Optimality And Stability Analysis Of 3DCT Scan Positions

Artem Amirkhanov 18

Limitations and Future Work

Orientation onlyDetect orientation and position in sequence

Still requires user interactionCombining parameters

Page 19: Visual Optimality And Stability Analysis Of 3DCT Scan Positions

Artem Amirkhanov 19

Conclusions