+ All Categories
Home > Documents > VLB Berlin Philipp Röbisch Versuchs- und Lehranstalt für Brauerei in Berlin (VLB) Mikrobiological...

VLB Berlin Philipp Röbisch Versuchs- und Lehranstalt für Brauerei in Berlin (VLB) Mikrobiological...

Date post: 18-Dec-2015
Category:
Upload: arnold-moody
View: 223 times
Download: 2 times
Share this document with a friend
Popular Tags:
7
VLB Berlin Philipp Röbisch Versuchs- und Lehranstalt für Brauerei in Berlin (VLB) Mikrobiological and macroscopic evaluation of different foam formulations for CIP applications in the brewing industry
Transcript
Page 1: VLB Berlin Philipp Röbisch Versuchs- und Lehranstalt für Brauerei in Berlin (VLB) Mikrobiological and macroscopic evaluation of different foam formulations.

VLB Berlin Philipp Röbisch

Versuchs- und Lehranstalt für Brauerei in Berlin (VLB)

Mikrobiological and macroscopic evaluation of different foam

formulations for CIP applications in the brewing industry

Page 2: VLB Berlin Philipp Röbisch Versuchs- und Lehranstalt für Brauerei in Berlin (VLB) Mikrobiological and macroscopic evaluation of different foam formulations.

VLB Berlin Philipp Röbisch

Experimental setup

CB

A20 x 20 cm

D stainless steel test plate

Page 3: VLB Berlin Philipp Röbisch Versuchs- und Lehranstalt für Brauerei in Berlin (VLB) Mikrobiological and macroscopic evaluation of different foam formulations.

VLB Berlin Philipp Röbisch

material and methods – foam types1. table: defining foam types2. picture: foam types a) dry b) middle c) wet

foam: alkaline foam with active chlorine component

foam proportion air

proportionwater

A dry high low

B medium

medium medium

C wet low high

1.

A) foam wet B) foam medium C) foam dry

2.

Page 4: VLB Berlin Philipp Röbisch Versuchs- und Lehranstalt für Brauerei in Berlin (VLB) Mikrobiological and macroscopic evaluation of different foam formulations.

VLB Berlin Philipp Röbisch

Contamination Kieselguhr contamination Spores contamination

concentration 10 g / L Kieselguhr suspension

spray 0,3 mL per square

spores suspension

2400 cfu / cm²

contamination:

detection:visually detection and evaluation after cleaning

semi quantitative detection with contact plates graduate in 10 categories

Page 5: VLB Berlin Philipp Röbisch Versuchs- und Lehranstalt für Brauerei in Berlin (VLB) Mikrobiological and macroscopic evaluation of different foam formulations.

VLB Berlin Philipp Röbisch

results

Page 6: VLB Berlin Philipp Röbisch Versuchs- und Lehranstalt für Brauerei in Berlin (VLB) Mikrobiological and macroscopic evaluation of different foam formulations.

VLB Berlin Philipp Röbisch

results

Page 7: VLB Berlin Philipp Röbisch Versuchs- und Lehranstalt für Brauerei in Berlin (VLB) Mikrobiological and macroscopic evaluation of different foam formulations.

VLB Berlin Philipp Röbisch

The End

Thank you for your attention! Cheers!


Recommended