VLX - LED Luminaire

The new VLX LED Series offers clean, functional styling that is defined by its sleek low profile design and rugged con-struction. It combines the latest LED performance and advanced LED thermal management technology, and provides lighting that is both energy efficient and aesthetically pleasing. Choose from 64 to 192 LEDs in one fixture size, that looks perfect with any of the LED configurations; thereby enabling the lighting designer to tailor the lighting to the application needs; while maintaining a uniform appearance throughout the entire project. Choose from a 7,000+ lumen package with life expectancy of well over 20 years; or 46,000+ lumens for your higher wattage needs. Consider Visionaire’s new “Vision-Net” dimming control system for affordable wireless control of your LED lighting sys-tem; for even more energy savings. For general parking, pedestrian areas, and roadways; the VLX LED series brings contemporary LED lighting design into the 21st century. Fixture Construction • Die-cast aluminum housing with integrated heat sink for maximum thermal management of the LEDs for extreme long life of the LEDs.• Two piece, tool-less entry, die-cast mounting arm and driver compartment for ease of mounting, and driver maintenance.• A pole mounting design that simplifies the installation of the fixture.• Engineered optical assemblies with six distribution patterns. LED Technology• 64 to 192 LEDs• 350,530,700 or 1000 mA ratings.• 9,000 to 46,000+ lumen package available.• 4000 or 5000 Kelvin for natural or white light.• Full cutoff optics available in six distribution patterns.• 69,000 to 126,000 hours or more of life for the LEDs• Add dimming controls for increased cost savings and project flexibility. Applications• The VLX LED Series is destined to become the standard for which LED area lights are measured. Simple flowing lines that house scalable LEDs that replace traditional HID fixtures; for a wide range of lighting applications. From shopping centers to auto dealerships; to general parking lots to roadways; the VLX LED series is the transition of LED lighting into tomorrow.

Die Cast AluminumIntegral Heat Sink

Built to draw heat away from the LED junction points for extended LED life.

LED Light EnginesThe LED light assemblies come in multiples of 32

(minimum 64 to maximum off 192 LEDs) and are field replaceable.

Full Cutoff OpticsAvailable in six different distribution patterns.

Easy Access Tool-less EntryPush button access to the driver compartment.

Die Cast Aluminum One PieceRemovable Door With

One - Piece Gasket For complete weather protection.

LED Driver(s) High performance with a power factor greater than

90%, and rated for -40° C operation. Supplied with quick disconnects for ease of service.

Terminal BlockFor easy power connection.

Maximum 8 gauge wire.

Surge Protector10 kV Surge protector supplied as standard.

Die Cast Aluminum Driver Compartment Separated from the LED array/heat sink structure; and provides easy driver access.

Safety Cable To limit door movement.

Die Cast AluminumQuick Mount Pole Cleat AssemblyFor ease of mounting

Dimensional Drawings

For more detailed information on mounting, wiring or installation instructions, please consult factory. If poles are not ordered with fixtures, please specify mounting requirements. This document contains proprietary information of Visionaire Lighting LLC. Any use of this information requires the written approval of Visionaire Lighting, LLC. In keeping with our TQM policy of continuous improvement, Visionaire reserves the right to change any specifications contained herein without prior notice.

VLX LED

Model Optics Source Current Voltage Mounting Finish Options

Arm Mount(AM)

Wall Mount*Cast Wall Plate (BAWP) to be ordered separately

(WM)

Round Pole Plate Adaptors (RPP) are to be ordered separately.

Bronze(BZ)

Black(BK)

Smooth Black(SBK)

White(WH)

Smooth White(SWH)

Graphite(GP)

Grey(GY)

Silver Metallic(SL)

Custom Color(CC)

Kelvin

4000K*Neutral white

(4K)

5000K*Cool white

(5K)

Photocell & Receptacle*Specify voltage

(PCR120) (PCR208)(PCR240) (PCR277)

Photo Receptacle (PER)*With shorting cap

Round Pole Plate AdaptorFor 3ӯ Pole (RPP3)For 4ӯ Pole (RPP4)For 5ӯ Pole (RPP5)

Cast Wall Plate(BAWP)

0-10v Dimming DriverNo Controls(DIM)

Motion Sensor*Works with FSP-211

(WSC-8)8’ Mounting Height(WSC-20)

9-20’ Mounting Height(WSC-40)

21-40’ Mounting Height

Wireless ControlConsult Factory

(WC)

Universal PoleMount Adaptor

(UPMA)

120-277*Universal

voltage

(UNV)

480(5)

Not available in 1 amp

347(8)

Not available in 1 amp

mA350(3)

530(5)

700(7)

1000*(10)

Type II(T2)

Type III(T3)

Type IV(T4)

Type IV-A(T4A)

Type IV-AR(T4AR)

Rotated Right

Type IV-AL(T4AL)

Rotated Left

Type V(T5)

Type V-W(T5W)

# of LEDs64

(64LC)

96(96LC)

128*(128LC)

160*(160LC)

192*(192LC)

VLX-1

*1000 mA NOT AVAILABLE FOR 128LC, 160LC OR 192LC

The new VLX LED Series offers clean, functional styling that is defined by its sleek low profile design and rugged construction. It combines LED performance and advanced LED thermal management technology and provides outdoor lighting that is both energy efficient and aesthetically pleasing.

The LED’s performance and the driver’s life are maximized by enclosing them in two separate die cast aluminum housings. Easy tool-less access for mounting and maintenance.

The LED light assemblies come with 64 to 192 LEDs. Six optical distribution patterns are available. Choose between 4000 or 5000 Kelvin temperature of the LEDs.

A durable polyester powder coat finish is guaranteed for five years; and is available in standard or custom colors.

The VLX LED series is an exceptional choice for commercial parking lots, office complexes, architectural projects, and other general lighting projects.

C

BD

A

2 1/2’’Ø 3/8’’

CL

1’’

1’’

Ø 1’’

Ø 3/8’’

VLX DRILL DIAGRAM

Project Name: Catalog Number: Type

Fixture A B C D Max. Watts LbsVLX-1 36” 4” 15.5” 4” 414 58

19645 Rancho Way Rancho Dominguez, CA 90220Tel: (310) 512-6480 Fax: (310) 512-6486

www.visionairelighting.com

VLX LED

Housing• Die cast aluminum LED housing with integral cooling fins for thermal management.

Mounting Arm/Driver Compartment•Durable two-piece die cast aluminum driver compartment utilizes a tool-less push button latch for ease of maintenance and sealed with a one-piece silicone gasket.

Thermal Management • The VLX series provides excellent thermal management by mounting the LEDs to the substantial heat sink of the housing. This enables the Luminaire to withstand higher ambient temperatures and driver currents without degrading LED life. • The L70 test determines the point in an LEDs life when it reaches 70 percent of its initial output. The VLX series LEDs have been determined to last 100,000+ hours in 25° C environments when driven at 350 mA.

Optical System • The highest lumen output, Evo/C LEDs are utilized in the VLX series. IES distribution Types II, III, IV, IV-A , V and V-W are available. The optical system qualifies as IES full cutoff to restrict light trespass, glare and light pollution.• CRI values are 70 for 4000K and 75 for 5000K.

Quali-Guard® Finish• The finish is a Quali-Guard® textured, chemically pretreated through a multiple-stage washer, electrostatically applied, thermoset polyester powder coat finish, with a minimum of 3-5 millimeter thickness. Finish is oven-baked at 400º F to promote maximum adherence and finish hardness. All finishes are available in standard and custom colors.• Finish is guaranteed for five (5) years.

Electrical Assembly• The VLX LED series is supplied with a choice of 350, 530, 700 or 1000 mA high-performance LED drivers that accept 120v thru 480v, 50 Hz to 60 Hz, input. Power factor of 90%. Rated for -40°C operations.• 10 kV surge protector supplied as standard.• Terminal block supplied as standard.

Warranty • Five (5) year Limited Warranty on entire system, including finish. For full warranty information, please visit visionairelighting.com. Options • Photocell & receptacle • Photo receptacle• Round pole plate adapter • Cast Wall Plate • 0-10v Dimming Driver• Motion Sensor• Wireless Control•Universal Pole Mount Adaptor Listings • The VLX is ETL listed, suitable for wet locations.• IP65 Rated• Powder Coated Tough.• DLC Listed

EPA Data

1.0 1.6 2.0 2.5 2.4 2.5

IP65RATED

DesignLights Consortium (DLC) qualified Product. Some configurations of this product family may not be Design-Lights Consortium (DLC) listed, please refer to the DLC qualified products list to confirm listed configurations. http://www.designlights.org/

VLX 5K LUMEN DATA# LED’s mA TYPE 1 B U G TYPE 2 B U G TYPE 3 B U G TYPE 4 B U G TYPE 4A B U G TYPE 5 B U G TYPE 5W B U G WATTS

64 350 9655 3 1 3 9015 2 1 2 9160 2 0 2 8634 1 1 2 9680 1 1 1 9388 3 0 1 9178 3 0 1 71

530 13382 3 1 3 12495 2 2 3 12695 2 0 2 11967 2 1 2 13416 2 1 2 13011 3 0 1 12720 3 0 2 103

700 16940 3 2 3 15817 3 2 3 16070 3 0 3 15148 3 2 3 16983 2 2 2 16470 3 0 2 16101 4 0 2 139

1000 21683 3 2 3 20245 3 2 3 20569 3 0 3 19389 3 2 3 21738 2 2 2 21081 4 0 2 20610 4 0 2 217

96 350 14448 3 2 3 13491 3 2 3 13707 2 1 2 12920 2 2 2 14486 2 2 2 14048 3 0 1 13734 3 0 2 108

530 20125 3 2 3 18791 3 2 3 19091 3 2 3 17996 3 2 3 20176 2 2 2 19567 4 0 2 19129 4 0 2 163

700 25801 4 2 4 24090 3 2 4 24476 3 2 3 23072 3 2 3 25867 2 2 3 25085 4 0 2 24524 4 0 2 215

1000 33033 4 2 4 30843 3 2 4 31337 3 2 3 29539 3 2 3 33118 3 2 3 32117 5 0 2 31399 5 0 3 328

128 350 18101 3 2 3 16901 3 2 3 17172 2 0 2 16187 2 2 3 18148 2 2 2 17599 3 0 2 17209 4 0 2 138

530 24772 4 2 4 23130 3 2 3 23500 3 0 3 22152 3 2 3 24836 2 2 2 24085 4 0 2 23547 4 0 2 203

700 30965 4 2 4 28913 3 2 4 29375 3 0 3 27690 3 2 3 31045 3 2 3 30107 4 0 2 29433 4 0 2 268

160 350 21944 3 2 3 20490 3 2 3 20818 3 0 3 19623 3 2 3 22001 2 2 2 21336 4 0 2 20859 4 0 2 168

530 30268 4 2 4 28262 3 2 4 28714 3 0 3 27067 3 2 3 30346 3 2 3 29429 5 0 2 23547 4 0 2 254

700 37835 4 2 4 35327 4 2 4 35893 3 0 3 33833 3 2 4 37932 3 2 3 36786 5 0 2 35964 5 0 3 336

192 350 25546 4 2 4 23853 3 2 4 24235 3 0 3 22844 3 2 3 25612 3 2 3 24838 4 0 2 24282 4 0 2 202

530 36229 4 2 4 33828 4 2 4 34369 3 0 3 32397 3 2 4 36322 3 2 3 35225 5 0 2 34437 5 0 3 306

700 46448 5 2 4 43369 4 2 5 44063 3 0 3 41535 3 2 4 46567 3 2 3 45160 5 0 2 44150 5 0 3 414

Visit www.VisionaireLighting.com for up-to-the-minute chart information, including types not listed here. *For 4000K multiply values by 0.95

07.21.15

LED Count Drive Current (mA) L70 (H)

64

350 126,000530 90,000700 81,0001000 76,500

LED Count Drive Current (mA) L70 (H)

96

350 121,000530 90,000700 80,1001000 75,600

LED Count Drive Current (mA) L70 (H)

128350 117,000530 81,000700 73,800

LED Count Drive Current (mA) L70 (H)

160350 112,500530 78,300700 71,100

LED Count Drive Current (mA) L70 (H)

192350 99,000530 76,500700 69,300

L70 DATA The L70 test determines the point in an LEDs life when it reaches 70 percent of its initial output. The VLX™ series LED’s have been determined to last 100,000+ hours in 25° C environments when driven at 350 mA.

THERMAL MANAGEMENT

The VLX Luminaire was designed with the goal of creating a robust product to last the test of time. Thermal management is absolutely a key factor in LED design. The VLX was engineered to separate the driver housing from the heat sink to allow for air flow between the compartments.

Within the design are spacers that are die cast into the driver compartment not exposed to the ele-ments, and allow for air flow between the heat sink and driver compartment. In keeping the compart-ments separate not only do we get excellent air flow, we eliminate heat between the light engine and the driver compartment.

2. Slip pole plate into top of pole and align to holes on pole making sure that pole plate is flush to inside of pole wall.

WARNING • To avoid possible risk of shock turn off power prior to installation or maintenance preferably at circuit breaker.

• Product must be installed following all NEC and local Electrical Codes.

3. Attach cleat assembly to pole (leave very loose) with the (2) grade 8 alloy steel hex head cap screws (Zinc yellow-plated 3/8” - 16 thread 2” lenght) attached to cleat assembly. Door mount bracket attached to cleat assembly must be at bottom.

4. Pull electrical power leads (by others) thru wire-way hole on pole. Make sure there is at least 12” of leads emerging from pole.

5. Slide luminaire arm between cleats.

8. Attach Door to luminaire.

9. Hook door to luminaire with safety cable.

10. Push door up to luminaire and close.

6. Firmly tighten luminaire with 30 ft-lb of torque to pole with (2) grade 8 alloy steel hex head cap screws attached to cleat assembly.

7. Make all electrical connections to inside of lumi-naire per NEC and/or any required local electrical codes. A terminal block is supplied.


Recommended