11/99 N/** 6.6.020.01 Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. VP40 3 Way Proportional Pressure Control Valve Nominal diameter 2 Direct operated poppet valves Flange design Low hysteresis Good repeatability High flow capacity at exhaust port Manifold mountable system Compact design Technical Data Medium: Filtered air, lubricated or unlubricated, Filter 50 μm Operation: Proportional solenoid Connection: Flange, subplate Flow direction: Fixed Operating pressure p 1 : 16 bar max. Pressure setting p 2 : 0 to 16 bar Ambient temperature: -10 to +40 °C Hysteresis: < 3 % (IN, p 2 max) Repeatability: * < 1 % (p 2 max) Linearity: * See characteristic curve Response sensitivity: * 1 % (p 2 max) Degree of protection: IP 65 with connector Mounting: Any position Materials: Body aluminium alloy Seals NBR (Perbunan) *Values referred to 20 °C with dither 20 % IN, 50 Hz Ordering Information 3 way proportional pressure control valve, ND 2, pressure setting 0 to 10 bar, Type: 4090020.7093.012.00 Subplate must be ordered separately. 2 3 1 Connectors See data sheet 7503364 Symbol
Transcript

11/99 N/** 6.6.020.01Our policy is one of continued research and development. We therefore reserve the rightto amend, without notice, the specifications given in this document.

VP40

3 Way Proportional Pressure Control Valve

Nominal diameter 2Direct operated poppet valves

Flange design

Low hysteresis

Good repeatability

High flow capacity at exhaust port

Manifold mountable system

Compact design

Technical DataMedium:

Filtered air, lubricated or unlubricated,Filter 50 µm

Operation:Proportional solenoid

Connection:Flange, subplate

Flow direction:Fixed

Operating pressure p1:16 bar max.

Pressure setting p2:0 to 16 bar

Ambient temperature:-10 to +40 °C

Hysteresis:< 3 % (IN, p2 max)

Repeatability: *< 1 % (p2 max)

Linearity: *See characteristic curve

Response sensitivity: *≤ 1 % (p2 max)

Degree of protection:IP 65 with connector

Mounting:Any position

Materials:Body aluminium alloySeals NBR (Perbunan)

*Values referred to 20 °C with dither 20 % IN, 50 Hz

Ordering Information3 way proportional pressure control valve, ND 2,pressure setting 0 to 10 bar,Type: 4090020.7093.012.00

Subplate must be ordered separately.

2

3 1

ConnectorsSee data sheet 7503364

Symbol

VP40 ND 2

N/** 6.6.020.02 11/99Our policy is one of continued research and development. We therefore reserve the rightto amend, without notice, the specifications given in this document.

General Information

Type Nominal diameter Connection Pressure Max. Operating Rated Current Drive WeightSetting p2 (bar) Pressure p1 (bar) (mA) Electronics (kg)

4090021.7093.012.00 2 Flange 0 to 6 7 805 pQ11, pQ12, pQ04 0,28

4090020.7093.012.00 2 Flange 0 to 10 12 1050 pQ11, pQ12, pQ04 0,28

4090022.7093.012.00 2 Flange 0 to 16 16 1500 pQ11, pQ12, pQ04 0,28

Voltage 12 V DC

Limiting current IN 1930 mA

Rated power PN 25 W

Resistance R20 6,3 Ω +3%

Duty cycle 100 %

Electrical Information for Proportional Solenoids

Drive ElectronicspQ11

Type Rated Current Electrical connection Remarks Description(mA)

5980083 0 to 1000 Connector acc. to DIN 43651 Suitable for 4090020.70935980087 0 to 1000 2 m Cable and 4090021.7093 valves

5980118 0 to 2400 Connector acc. to DIN 43651 Suitable for 4090022.7093 valve

5980119 0 to 2400 2 m Cable

Plug-in type amplifier with constant currentregulator PDM. Degree of Protection: IP 65.Power supply: 18 to 32 V DC Residual ripple: ≤10 %.Ambient temperature: 0 to +50 °C.Mounting: Any position

Type Rated Current Remarks Description(mA)

5980126 0 to 2400 Suitable for 4090020.7093and 4090021.7093 valves

5980127 0 to 1000 Suitable for 4090022.7093 valve

Amplifier module with constant current regulatorPDM. Degree of Protection: IP 20.Power supply: 18 to 32 V DC Residual ripple: ≤10 %.Ambient temperature: 0 to +50 °C.Mounting: Any position.For attachment on mounting rail acc. to EN 50022

pQ12

Type Description Specification

0680003 Connector DIN 43650 Form B small

0014400 Silencer M5

Accessories

Data sheet 6.6.030

Data sheet 6.6.031

Type Rated Setpoint Ramps PID-controller for Remarks DescriptionCurrent (mA) Input closed loop contr.

5988020 0 to 2400 0 to ±10 V 4 no Suitable for valves4090XXX, 4088XXX

5988022 0 to 2400 0 to ±10 V 4 yes Suitable for valves4090XXX, 4088XXX

Digital amplifier module with constant currentregulator PDM.Power supply: 18 to 32 V DC Residual ripple: ≤10 %.Ambient temperature: 0 to +50 °C.Weight: 0,4 kg

pQ04

Data sheet 7503188

VP40 ND 2

11/99 N/** 6.6.020.03Our policy is one of continued research and development. We therefore reserve the rightto amend, without notice, the specifications given in this document.

Characteristic curves Flow characteristic for 7 bar operating pressure

6,0

p2 (bar)

(mA)

(mA)

(mA)

p2 = f (W)

5,4

4,8

4,2

3,6

3,0

2,4

1,8

1,2

0,6

0 115 230 345 460 575 690 805

0 150 300 450 600 750 900 1050

1400 15001000 1200800200 400 6000

10

9

8

7

6

5

4

3

2

1

0

16

14

12

10

8

6

4

2

0

p2 (bar)

Q (l/min)

p2 = f (Q) at p1 = 7 bar

6

5

4

3

2

1

0 80 160 240

Flow characteristic for 12 bar operating pressure Flow characteristic for 16 bar operating pressurep2 (bar)

Q (l/min)

p2 = f (Q) at p1 = 16 bar16

14

12

10

8

6

4

2

0 80 160 240 320 400 480

p2 (bar)

Q (l/min)

p2 = f (Q) at p1 = 12 bar10

8

6

4

2

0 80 160 240 320 400

VP40 ND 2

N/** 6.6.020.04 11/99Our policy is one of continued research and development. We therefore reserve the rightto amend, without notice, the specifications given in this document.

General Dimensions, Valve

16

25 36

12,5

19,5

32

75

244

32

4,3

424

M54,

23,8

2 1,1

5

27

1

2

1

2

3

Ø 6

,4 7,5

7,5

14

1 1(3) (3)

2

13Ø 7

,27

G1/8

8M

5

4,3

172432

24

32

M4x6 deep

G1 /

8

10

8

2,5

General Dimensions, Subplate

G 1/8 SubplateType: 0601740 to be ordered separately

Screw plug for open portType: 0568384 to be ordered separately

VP40 ND 2

11/99 N/** 6.6.020.05Our policy is one of continued research and development. We therefore reserve the rightto amend, without notice, the specifications given in this document.

22222

1(3) 1(3)

C4 C

B

A

16 33

Typ Description Weight (kg)

0601740 Single Subplate Assembly 0,04

0601741 Manifold bar – 2 Valves 0,08

0601742 – 3 Valves 0,13

0601743 – 4 Valves 0,17

0601744 – 5 Valves 0,21

0601745 – 6 Valves 0,24

0559301 Nipple -

0602005 Blind Plate Assembly 0,22

0568384 Screw Plug G 1/8 -

Components

Manifold system

3

2

2

2

2

1

Manifold bar

Blind plate

Nipple

Single subplate

Manifold bar, basic dimensions

Type No. of valves A B C

0601741 2 65 57 -

0601742 3 98 90 -

0601743 4 131 123 -

0601744 5 164 156 57

0601745 6 197 189 57

VP40 ND 2

N/** 6.6.020.06 11/99Our policy is one of continued research and development. We therefore reserve the rightto amend, without notice, the specifications given in this document.

21,5

G1 /

8

1824

26

3

9

7 32

24

32,2

6,5

G1/4

M4

Type Description Weight (kg)

0541070 Stacking plate (without valve) 0,04supplied with 2 brackets and1 O-ring

0657380 Screw plug G 1/4 -

0660835 Sealing ring for 0657380 -

0663083 O-ring -

0541281 Bracket for stacking plates -

Components

Stacking system

3

2

2

2

1

O-ring

Bracket for stacking plate

Stacking plate

Stacking Plate Dimensions

Warning. Bores of mounting bracket must not be used for fastening of stacking system.

64,4

96,6

VP40 ND 2

11/99 N/** 6.6.020.07Our policy is one of continued research and development. We therefore reserve the rightto amend, without notice, the specifications given in this document.

Type Description Weight (kg)

0543862 Flange assembly 0,1supplied with screw, G 1/8

Components

Flanged System

Flange Assembly Dimensions

2 1

G1 /

8

G1 /

8

20

7

48

8

M4

7

10

9,5

2432 3

14,5 7

24

32

These products are intended for use in industrial compressed air systems only. Do notuse these products where pressures and temperatures can exceed those listed under‘Technical Data’.Before using these products with fluids other than those specified, for non-industrialapplications, life-support systems, or other applications not within publishedspecifications, consult NORGREN.Through misuse, age, or malfunction, components used in fluid power systems canfail in various modes. The system designer is warned to consider the failure modes of

all component parts used in fluid power systems and to provide adequate safeguardsto prevent personal injury or damage to equipment in the event of such failure.System designers must provide a warning to end users in the systeminstructional manual if protection against a failure mode cannot be adequatelyprovided.System designers and end users are cautioned to review specific warnings found ininstruction sheets packed and shipped with these products where applicable.

Warning

VP40 ND 2

N/** 6.6.020.08 11/99Our policy is one of continued research and development. We therefore reserve the rightto amend, without notice, the specifications given in this document.

11/99 N/** 6.6.022.01Our policy is one of continued research and development. We therefore reserve the rightto amend, without notice, the specifications given in this document.

VP40

3 Way Proportional Pressure Control Valve

Nominal diameter 4, 6 and 8Direct operated poppet valve

Port sizes G 1/8 - G 3/8, 1/8 NPT - 3/8 NPT

Low hysteresis

Good repeatability

High flow capacity at exhaust port

High response sensitivity

Fast response time

Technical DataMedium:

Filtered air, lubricated or unlubricated,Filter 40 µm

Operation:Proportional solenoid

Port Size:G 1/8 - G 3/8, 1/8 NPT - 3/8 NPTFemale thread

Flow direction:Fixed

Operating pressure p1:20 bar max.

Pressure setting p2:0 to 20 bar

Ambient temperature:-10 to +40 °C

Hysteresis: *< 3 % (lN max, p2 max)

Repeatability: *< 1 % (p2 max)

Linearity: *See characteristic curve

Response sensitivity: *< 1 % (lN max, p2 max)

Degree of protection:IP 65 with connector

Mounting:Any, preferably vertical

Material:Body aluminium alloySeals NBR (Perbunan)

* Values referred to 20 °C with dither 20% lN, 50 Hz

Ordering Information3 way proportional pressure control valve, ND 4,pressure setting 0 to 10 bar,port size G 1/4Type: 4088110.7053.012.00

Alternative ModelsWith thread connection NPT

ConnectorsSee data sheet 7503364

2

3 1

VP40 ND 4, 6, 8

N/** 6.6.022.02 11/99Our policy is one of continued research and development. We therefore reserve the rightto amend, without notice, the specifications given in this document.

General Information

Type Nominal diameter Port size Pressure Setting Max. Operating Rated Current Drive Weightp2 (bar) Pressure p1 (bar) lN (mA) Electronics (kg)

4088110.7053.012.00 4 G 1/8 0 to 10 10 0 to 1600 (1800) pQ11, pQ12, pQ04 0,8

4088218.7071.012.00 4 G 1/8 0 to 20 20 see data sheets 0,8

4088200.7053.012.00 6 G 1/4 0 to 2,1 7 7502961, 1,0

4088210.7053.012.00 6 G 1/4 0 to 10 12 7503109, 1,0

4088310.7071.012.00 8 G 3/8 0 to 7 10 7503188 1,2

Voltage 12 V DC

Limiting current IN 1840 mA

Rated power PN 22 W

Resistance R20 6,5 Ω ±3%

Duty cycle 100 %

Proportional Solenoids

Type Description Specification

0570275 Connector DIN 43650 Form A

Accessories

Drive ElectronicspQ11

Type Rated Current Electrical connection Remarks Description(mA)

5980081 0 to 2400 Connector acc. to DIN 43651 Suitable for valves5980085 0 to 2400 2 m Cable 4088XXX.XXXX

Plug-in type amplifier with constant currentregulator PDM. Degree of Protection: IP 65.Power supply: 18 to 32 V DC Residual ripple: ≤10 %.Ambient temperature: 0 to +50 °C.Mounting: Any position

Type Rated Current Remarks Description(mA)

5980126 0 to 2400 Suitable for valves4088XXX.XXXX

Amplifier module with constant current regulatorPDM. Degree of Protection: IP 20.Power supply: 18 to 32 V DC Residual ripple: ≤10 %.Ambient temperature: 0 to +50 °C.Mounting: Any position.For attachment on mounting rail acc. to EN 50022

pQ12

Data sheet 6.6.030

Data sheet 6.6.031

Type Rated Setpoint Ramps PID-controller for Remarks DescriptionCurrent (mA) Input closed loop contr.

5988020 0 to 2400 0 to ±10 V 4 no Suitable for valves4090XXX, 4088XXX

5988022 0 to 2400 0 to ±10 V 4 yes Suitable for valves4090XXX, 4088XXX

Digital amplifier module with constant currentregulator PDM.Power supply: 18 to 32 V DC Residual ripple: ≤10 %.Ambient temperature: 0 to +50 °C.Weight: 0,4 kg

pQ04

Data sheet 7503188

These products are intended for use in industrial compressed air systems only. Do notuse these products where pressures and temperatures can exceed those listed under‘Technical Data’.Before using these products with fluids other than those specified, for non-industrialapplications, life-support systems, or other applications not within publishedspecifications, consult NORGREN.Through misuse, age, or malfunction, components used in fluid power systems canfail in various modes. The system designer is warned to consider the failure modes of

all component parts used in fluid power systems and to provide adequate safeguardsto prevent personal injury or damage to equipment in the event of such failure.System designers must provide a warning to end users in the systeminstructional manual if protection against a failure mode cannot be adequatelyprovided.System designers and end users are cautioned to review specific warnings found ininstruction sheets packed and shipped with these products where applicable.

Warning

VP40 ND 4, 6, 8

11/99 N/** 6.6.022.03Our policy is one of continued research and development. We therefore reserve the rightto amend, without notice, the specifications given in this document.

Characteristic curvesType: 4088110

Type: 4088218

Type: 4088200

10

p2 (bar)

I (mA)

p2 = f (I)

9

8

7

6

5

4

3

2

1

0 200 400 600 800 1000 1200 1400 1600

10

p2 (bar)

Q (l/min)

p2 = f (Q)

9

8

7

6

5

4

3

2

1

0 160 320 480 640 800

p1 = 10 barp2 = adjusted at Q=0

p2 = 10 bar

p2 = 8 bar

p2 = 6 bar

p2 = 4 barp2 = 2 bar

20

p2 (bar)

I (mA)

p2 = f (I)

18

16

14

12

10

8

6

4

2

0 200 400 600 800 1000 1200 1400 18001600

p2 (bar)

Q (l/min)

p2 = f (Q)

6

8

10

12

14

16

18

20

4

2

0 320 640 960 1280 20801600 1920

p1 = 20 barp2 = adjusted at Q=0

p2 = 6 barp2 = 2 bar

p2 = 8 bar

p2 = 10 bar

p2 = 12 bar

p2 = 14 bar

p2 = 16 bar

p2 = 18 bar

p2 = 20 bar

2,02,1

p2 (bar)

I (mA)

p2 = f (I)

1,8

1,6

1,4

1,2

1,0

0,8

0,6

0,4

0,2

0 200 400 600 800 1000 1200 1400 1600

2

p2 (bar)

Q (l/min)

p2 = f (Q)

1,5

1

0,5

0 160 320 480 640 800

p1 = 7 barp2 = adjusted at Q=0

p2 = 1 bar

p2 = 2 bar

p2 = 1,5 bar

p2 = 0,5 bar

VP40 ND 4, 6, 8

N/** 6.6.022.04 11/99Our policy is one of continued research and development. We therefore reserve the rightto amend, without notice, the specifications given in this document.

Pg 11

N

F

D

3

1

2

C2B

2

E1

C1

E2

C3

B1

A2

A1

A3

L

H

6,5

M

12

Type A1 A2 A3 B1 B2 C1 C2 C3 D E1 E2 F H L M N

4088110 1/8 1/8 1/8 23 50,5 36 36 34 50 121 62,5 35 131 89 52,5 50

4088218 1/4 1/4 1/8 26,5 44,5 40 34 34 50 121 56,5 45 128 94 57 50

4088200 1/4 1/4 1/4 30 50 43 38 49 60 117 58,5 35 127 94 57,5 40

4088210 1/4 1/4 1/8 26,5 44,5 40 34 34 50 115 56,5 35 125 89 52,5 50

4088310 3/8 3/8 3/8 36,5 67 52 52 50 70 142 77,5 45 149,5 104 67 55

Type: 4088310p2 (bar)

I (mA)

p2 = f (I)

7

6

5

4

3

2

1

0 200 400 600 800 1000 1200 1400 1600

p2 (bar)

Q (l/min)

p2 = f (Q)

3

4

5

6

7

2

1

0 400 800 1200 1600 2000

p1 = 10 barp2 = adjusted at Q=0

p2 = 7 barp2 = 6 barp2 = 5 barp2 = 4 bar

p2 = 2 bar

p2 = 3 bar

p2 = 1 bar

Type: 4088210

10

p2 (bar)

I (mA)

p2 = f (I)

9

8

7

6

5

4

3

2

1

0 200 400 600 800 1000 1200 1400 1600

p2 (bar)

Q (l/min)

p2 = f (Q)

3

4

5

6

7

8

9

10

2

1

0 320 640 960 1280 1440

p1 = 12 barp2 = adjusted at Q=0

p2 = 6 bar

p2 = 8 bar

p2 = 10 bar

p2 = 4 barp2 = 2 bar

General Dimensions


Recommended