VPE Workbench 5.6 SP1 Product Overview
Transcript
  • VPE Workbench 5.6 SP1Product Overview

  • VPE Workbench 5.6 SP1

    VPE Workbench 5.6 SP1 contains the following new functionality Production of Fieldbus/Profibus wiring diagrams Production of Instrument hook-up documents Miscellaneous field definition for Process Areas User definable attributes added to Nozzles User definable attributes added to Mechanical

    Connections form V-5008 A copy project utility is now available that copies

    the project to the same or a different oracle database

  • Fieldbus/Profibus Wiring diagrams

    Workflow steps to support fieldbus/profibusdiagram creation Create I/O Types Load / Create the necessary field

    devices/instruments within VPE Workbench Create suitable Field Bus Item Types Define field device termination patterns [i.e.

    specify the various terminal and field device cable details]

    Apply the field device patterns to the necessary instruments

  • Fieldbus/Profibus Wiring diagrams

    Workflow steps to support fieldbus/profibusdiagram creation Define field device unit [FDU] templates Define field bus segment templates [Field Bus

    Loops - each loop to contain a number of FDUs] Preview / generate actual field bus segments

    based on a field bus segment Assign the necessary field instruments Fine tune segments Create diagrams

  • Fieldbus/Profibus Wiring diagrams

    Create I/O Types IO types are created in form V-2115

    NOTE: The Create Multiple I/O (Y or N) option mustbe set to N for the fieldbus functionality to work.

  • Fieldbus/Profibus Wiring diagrams

    Create suitable fieldbus/profibus item types using the Data Management Wizard form V-DMO1

  • Fieldbus/Profibus Wiring diagrams

    Define field device termination patterns using form V-2501

  • Fieldbus/Profibus Wiring diagrams

    Apply field device termination patterns to instruments using form V-2502

  • Fieldbus/Profibus Wiring diagrams

    Define field device unit template using form V-2500

  • Fieldbus/Profibus Wiring diagrams

    Define field bus segments (loops) using form V-9061

  • Fieldbus/Profibus Wiring diagrams

    Generate tagged field bus segments using form V-9062

    Use Preview to see the segments that will be created

  • Fieldbus/Profibus Wiring diagrams

    Assign instruments to FDUs in a field bus segment using form V-9063

  • Fieldbus/Profibus Wiring diagrams

    Fine tune the field bus segments using form V-2515

  • Fieldbus/Profibus Wiring diagrams

    Create Diagrams Templates are created in AutoCAD (2006) and

    data designators (placeholders) added to them via the Document Wizard

    Fieldbus/Profibus loop diagrams are then generated from the Schematics Workbench

  • Hook-up diagrams

    Workflow steps to support hook-up diagram creation Define hook-up template Assign Excel Worksheet to template set Add data designators (placeholders) to the

    Worksheet Create hook-up document Allocate parts to hook-up document Assign hook-up document to instruments Generate the document Hook-up parts summary

  • Hook-up diagrams

    Define hook-up template

  • Hook-up diagrams

    Assign Excel Worksheet to template set via the Document Wizard

  • Hook-up diagrams

    Add data designators (placeholders) to the Worksheet

  • Hook-up diagrams

    Create hook-up Document

  • Hook-up diagrams

    Allocate parts to hook-up Document

  • Hook-up diagrams

    Assign hook-up document to instruments

  • Hook-up diagrams

    Generate hook-up document

  • Hook-up diagrams

    There is also a utility that displays a hook-up document parts summary

  • VPE Workbench 5.6 SP1

    VPE Workbench 5.6 SP1 contains improvements to the following existing functionality Enhanced error handling in the Excel Interface

    Wizard List of Values value field length in form V-6002

    increased from 500 to 4000 characters Field lengths increased for better multi-byte

    character support in 366 forms ( for details see http://avevaportal/sites/VPEProdCollateralPublic/Shared%20Documents/VPE%20Workbench%20Presentations%20and%20Movies/VPE%20Workbench%205.6%20SP%201%20Form%20field%20length%20changes.xls)

  • VPE Workbench 5.6 SP1

    VPE Workbench 5.6 SP1 contains improvements to the following existing functionality Configurable miscellaneous field tab titles Write API enhancements to the error handling

    and only data that has changed since the last import will be updated

    Electrical items can now inherit their tag details from the associated powered item

    Improvements to the P&ID MTO User role additions to support VPE 7.1

  • VPE Workbench 5.6 SP1

    At VPE Workbench 5.6 base release the Oracle infrastructure was changed Only available on Oracle 10g release 1

    VPE Workbench 5.6 SP1 also only available on Oracle 10g release 1

  • VPE Workbench 5.6 SP1Fieldbus/Profibus Wiring diagramsFieldbus/Profibus Wiring diagramsFieldbus/Profibus Wiring diagramsFieldbus/Profibus Wiring diagramsFieldbus/Profibus Wiring diagramsFieldbus/Profibus Wiring diagramsFieldbus/Profibus Wiring diagramsFieldbus/Profibus Wiring diagramsFieldbus/Profibus Wiring diagramsFieldbus/Profibus Wiring diagramsFieldbus/Profibus Wiring diagramsFieldbus/Profibus Wiring diagramsHook-up diagramsHook-up diagramsHook-up diagramsHook-up diagramsHook-up diagramsHook-up diagramsHook-up diagramsHook-up diagramsHook-up diagramsVPE Workbench 5.6 SP1VPE Workbench 5.6 SP1VPE Workbench 5.6 SP1