Date post: | 10-Apr-2018 |
Category: |
Documents |
Upload: | marina-santamaria |
View: | 220 times |
Download: | 0 times |
of 4
8/8/2019 VRV-S Leaflet - LVSUSE08-08C - Daikin
1/4
Air-Cooled DX
Multizone System
Single Phase
Available in 3 and 4 Ton
Individual zone control
Can operate up to 6 or 8 an coil units
Optimized design or R-410A
INVERTER
R-410A
Variable RefrigerantVolume
Air-Coold DXMultizon Sstm
Advanced Zoning Capabilities
Energy Efciency
Innovative Space-Saving Design
Reliability
Outstanding Warranties
8/8/2019 VRV-S Leaflet - LVSUSE08-08C - Daikin
2/4
www.daikinac.com
VRV-S Features & Benefts
hoice3 and 4 Ton
208 ~ 230V/1-phase power or residential and light commercial applications.
dvanced Zoning Individual Zones o up to 6 or 8 zones.
ndependent ControlEach an coil unit uses a dedicated electronic expansion valve or superior room temperature control,meaning individual control in all necessary zones.
FD/Capacity Control
At the heart o the condensing unit is a high eciency variable speed inverter compressor coupled with inverter anmotors or superior system part load perormance.
Compressor capacity is modulated automatically to maintain a constant suction pressure, while varying the rerigerantvolume to precisely deliver the needs o the cooling or heating loads.
Indoor units use an Electronic Expansion Valve (EEV) to control the cooling or heating perormance, with PID logic takipriority when the room termperature to set-point dierential is +/-3 F, to deliver a comortable room temperature con
Optimized R-410A DesignThe industry benchmark is the worlds rst R-410A operated variable rerigerant volume (VRV) system and represents aconsiderable advance in eciency over competitive systems.
lexible Design
Continuous operation 0F DB (-5F WB) - 64F DB (60F WB) in heating mode and 23F DB - 115F DB in cooling mode
Long rerigerant lines, up to 1,000 eet o pipe (492 eet max. linear liquid piping length), 165 height dierence.
Ability to interace with an external heating system.
ndoor UnitsA choice o ducted an coils, 4-way cassette, ceiling suspended, wall mounted or foor console.
Capacities rom 1/2 (7MBH) to 4 (48MBH) Ton.
imple Wiring Daisy chain control wiring, 2 wire non-shielded, non-polarized cable or simple installation.
nergy Efciency
Inverter technology allows high part load eciency enabling the compressor speed to vary according to the cooling/heload and consume only the power necessary to match that load.
Superior heating capability with operation as low as -5FWB (0FDB).
Outside Air Outside air capability with ducted an coils and ductless cassette units.
pace Saving Very compact outdoor unit with a depth o 12 5/8.
dvanced DiagnosticsThe advanced, sel-diagnostic, auto-check unction will detect a malunction and immediately display the type and locso it can be resolved quickly and eectively.
CD Remote Control Controls up to 16 zones and provides a host o operational unctions.
Quiet Indoor and outdoor units oer quiet operation. FXFQ indoor unit has a sound pressure level as low as 28dB(A).
THE SIMPLIFIED VRV-S SYSTEM TAKES AIR
CONDITIONING TO THE NEXT LEVEL.
The VRV-S provides a long piping length o 492 t (575t equivalent piping length), with a total piping lengtho1,000 t. I the outdoor unit is installed above theindoor units, the height can be up to a maximum o 165 t.These generous allowances acilitate an extensive variety odesigns.
The entire pipe network is also acilitated by the use o theREFNET tubing connectors, which reduces the installationtime.
Due to its versatile design, the VRV-S System is perect orinstallation foor by foor. It increases revenue by simplymaking the space available, quicker. Inverter Heat Pump
One system or either heating or cooling
8/8/2019 VRV-S Leaflet - LVSUSE08-08C - Daikin
3/4
www.daikinac.com
0.6 Ton 0.75 Ton 1.0 Ton 1.5 Ton 2.0 Ton 2.5 Ton 3.0 Ton 4.0
OOR UNITS - FXSQ Concald Ciling Unit (208 - 230V /
Model FXSQ09MVJU FXSQ12MVJU FXSQ18MVJU FXSQ24MVJU FXSQ30MVJU FXSQ36MVJU FXSQ4
Cooling Capacity Btu/h
Contact Daikin orurther details
12,000 18,000 24,000 30,000 36,000 48
Heating Capacity Btu/h 13,500 20,000 27,000 34,000 40,000 54
Sound Pressure Level H/L dB(A) 41/35 1 44/38 1 44/38 1 45/39 1 45/39 1 48
Airfow H/L cm 340/230 530/390 740/490 950/720 990/740 1,30
Weight lbs. 69 73 95 119 119 1
Dimensions (H x W x D) in. 11 7/8 x 21 5/8 x 31 1/2 11 7/8 x 27 1/2 x 31 1/2 11 7/8 x 39 3/8 x 31 1/2 11 7/8 x 55 1/8 x 31 1/2
OOR UNITS - FXMQ Concald Ciling Unit (mdium static) (208 - 230V /
Model FXMQ30MVJU FXMQ36MVJU FXMQ
Cooling Capacity Btu/h 30,000 36,000 48
Heating Capacity Btu/h 34,000 40,000 54
Sound Pressure Level H/L dB(A) 45/41 2 45/41 2 48
Airfow H/L cm 690/565 1,020/810 1,27
Weight lbs. 99 139 1
Dimensions (H x W x D) in. 15 3/8 x 28 3/8 x 27 1/8 15 3/8 x 43 3/4 x 27 1/8
OOR UNITS - FXDQ Slim Duct Built-In Concald Ciling Unit (208 - 230V /
Model FXDQ07MVJU FXDQ09MVJU FXDQ12MVJU FXDQ18MVJU FXDQ24MVJU
Cooling Capacity Btu/h 7,500 9,500 12,000 18,000 24,000
Heating Capacity Btu/h 8,500 10,500 13,500 20,000 27,000
Sound Pressure Level H/L dB(A) 33/29 2 33/29 2 33/29 2 35/31 2 36/32 2
Airfow H/L cm 280/226 280/226 280/226 440/350 580/460
Weight lbs. 49 49 49 68 75
Dimensions (H x W x D) in. 7 7/8 x 27 9/16 x 24 7/16 7 7/8 x 35 7/16 x 24 7/16 7 7/8 x 43 5/16 x 24 7/16
OOR UNITS - FXOQ Vrtical Air Handling Unit (FXOQ42MVJU modl also availabl) (208 V /
Model FXOQ12MVJU FXOQ18MVJU FXOQ24MVJU FXOQ30MVJU FXOQ36MVJU FXOQ
Cooling Capacity Btu/h 12,000 18,000 24,000 30,000 36,000 48
Heating Capacity Btu/h 12,000 18,000 24,000 30,000 40,000 54
Sound Pressure Level H/L dB(A) N/A N/A N/A N/A N/A N
Airfow H/L cm 400 600 800 1,000 1,200 1,
Weight lbs. 120 120 120 140 210 2
Dimensions (H x W x D) in. 44 x 22 x 15 44 x 22 x 15 44 x 22 x 15 48 x 22 x 18.5 49 x 26 x 20 49 xBEQ box model BEQ12MVJLR1 BEQ18MVJLR1 BEQ24MVJLR1 BEQ30MVJLR1 BEQ36MVJLR1 BEQ48
OOR UNITS - FXFQ 4 Wa Ciling Mountd Casstt Unit (3x3) (208 - 230V /
Model FXFQ07MVJU FXFQ09MVJU FXFQ12MVJU FXFQ18MVJU FXFQ24MVJU FXFQ30MVJU FXFQ36MVJU
Cooling Capacity Btu/h
Contact Daikin orurther details
Contact Daikin orurther details
12,000 18,000 24,000 30,000 36,000
Heating Capacity Btu/h 13,500 20,000 27,000 34,000 40,000
Sound Pressure Level H/L dB(A) 31/28 2 33/28 2 34/29 2 38/32 2 40/33 2
Airfow H/L cm 460/350 570/390 670/490 990/710 990/740
Weight (panel weight) lbs. 55 (11) 55 (11) 55 (11) 66 (11) 66 (11)
Unit Dimensions (H x W x D) in. 9 1/8 x 33 1/8 x 33 1/8 11 3/8 x 33 1/8 x 33 1/8
Panel Dimensions (H x W x D) in. 1 5/8 x 37 3/8 x 37 3/8
OOR UNITS - FXZQ 4 Wa Cilling Mountd Casstt Unit (2x2) *Availabl in April 2008* (208 - 230V /
Model FXZQ07M7VJU FXZQ09M7VJU FXZQ12M7VJU FXZQ18M7VJU
Cooling Capacity Btu/h 7,500 9,500 12,000 18,000
Heating Capacity Btu/h 8,500 10,500 13,500 20,000
Sound Pressure Level H/L dB(A) 31/29 2 31/29 2 33/29 2 41/34 2
Airfow H/L cm 320/247 320/247 335/265 495/353
Weight lbs. 41.9 41.9 41.9 41.9
Dimensions (H x W x D) in. 11 1/4 x 22 5/8 x 22 5/8
Panel Dimensions (H x W x D) in. 2 5/32 x 27 9/16 x 27 9/16OOR UNITS - FXHQ Ciling Suspndd Casstt Unit (208 - 230V /
Model FXHQ12MVJU FXHQ24MVJU FXHQ36MVJU
Cooling Capacity Btu/h 12,000 24,000 36,000
Heating Capacity Btu/h 13,500 27,000 40,000
Sound Pressure Level H/L dB(A) 38/33 3 44/36 3 46/41 3
Airfow H/L cm 410/340 710/600 830/670
Weight lbs. 55 80 90
Dimensions (H x W x D) in. 7 11/16 x 37 13/16 x 26 3/4 7 11/16 x 55 1/8 x 26 3/4 7 11/16 x 62 5/8 x 26 3/4
OOR UNITS - FXAQ Wall Mountd Unit (208 - 230V /
Model FXAQ07MVJU FXAQ09MVJU FXAQ12MVJU FXAQ18MVJU FXAQ24MVJU
Cooling Capacity Btu/h 7,500 9,500 12,000 18,000 24,000
Heating Capacity Btu/h 8,500 10,500 13,500 20,000 27,000
Sound Pressure Level H/L dB(A) 36/31 3 37/31 3 38/31 3 43/37 3 47/40 3
Airfow H/L cm 265/160 285/175 300/180 500/400 635/470
Weight lbs. 25 25 25 31 31
Dimensions (H x W x D) in. 11 3/8 x 31 1/4 x 9 11 3/8 x 41 3/8 x 9
OOR UNITS - FXLQ Floor Consol Unit (208 - 230V /
Model FXLQ12MVJU FXLQ18MVJU FXLQ24MVJU
Cooling Capacity Btu/h 12,000 18,000 24,000
Heating Capacity Btu/h 13,500 20,000 27,000
Sound Pressure Level H/L dB(A) 36/33 4 40/35 4 41/36 4
Airfow H/L cm 280/210 490/380 560/420
Weight lbs. 66 80 80
Dimensions (H x W x D) in. 23 5/8 x 44 7/8 x 8 3/4 23 5/8 x 55 7/8 x 8 3/4
OOR UNITS - FXNQ Concald Floor Consol Unit (208 - 230V /
Model FXNQ12MVJU FXNQ18MVJU FXNQ24MVJU
Cooling Capacity Btu/h 12,000 18,000 24,000
Heating Capacity Btu/h 13,500 20,000 27,000
Sound Pressure Level H/L dB(A) 36/33 4 40/35 4 41/36 4
Airfow H/L cm 280/210 490/380 560/420
Weight lbs. 51 59 59
Dimensions (H x W x D) in. 24 x 42 1/8 x 8 5/8 24 x 53 1/8 x 8 5/8
s: 1 at 5 t blow bottom suction grill o unit 2 at 5 t blow th unit 3 at 3.3 t blow and rom th unit 4 masurd at 5 t awa, 5 t high
A wide variety o ducted and duct-ree indoor an coil uni
The FXOQ + BEQ unitcannot be installed onthe same system as thatcontaining Indoor Unitsfrom another VRV Indoor
Unit family
Condensate Pump Standard
Condensate Pump Standard
Condensate Pump Standard
Condensate Pump Standard
8/8/2019 VRV-S Leaflet - LVSUSE08-08C - Daikin
4/4
Form: LVSUSE08-08C
LonWorks
NeTWORkS COMPATIBLe GATeWAy
Interface for connection toLonWorks
networks
Communication via LON
protocol (twisted pair wire)
64 units connectable
Unlimited site size
Quick, easy installation
BACnt NeTWORkS COMPATIBLe GATeWAy
Interface for BMS system
Communication via BACnet protocol(connection via ethernet)
256 units connectable per BACnet gatewaywith optional expander board
Unlimited site size
Quick, easy installation
Daiin AC (Amricas), Inc.1645 Wallac Driv, Suit 110Carrollton, TX 75006 USA
Tl: 972-245-1510Toll Fr: 866-4DAIkINVisit us at www.daikinac.com
64 groups (128 indoor unconnectable, another 64 g(128 indoor units) connecwith DIH-Net adaptor opt
Management of AC units,acilities, and ancillary equ
Touch screen display
Built-in Ethernet port,Web enabled (optional)
Daikins products are subject to continuousimprovements. Daikin reserves the right tomodiy product design, speciications andinormation in this brochure without noticeand without incurring any obligations.
Individual Zon Controllrs Multi-Zon Controllrs Tim Cloc Controllrs
Da ProgrammablWird R/CBRC1D71
SimplifdWird R/CBRC2A71
Wirlss R/CBRC7C812BRC7e83BRC4C82BRC7e818
Unifd On/O R/CDCS301C71
Cntralizd R/CDCS302C71
Schdul TimrDST301BA61
1,024 groups(2,048 groups)connectable
Management of AC units, facilities, andancillaryequipment
Operation on 1 master PCand 1 sub PC
Remote monitoring via the web
Cooling Hating Low Hating 17 Festimatd Natio
Avrag AnnuaOprating Cos
OutdoorUnit Indoor Units CombinationARI
RrncNumbr
NominalCapacit(Btu/h)
eeRSeeR
NominalCapacit(Btu/h)
COPHSPF
Capacit(Btu/h)
COP Cool Hat95 F 47 F
XyMQ36MVJU
Non-Ducted Indoor Units 3024378 38,000 11.20 14.30 42,000 2.90 8.15 29,600 2.00 $229 $338
Ducted Indoor Units 3024380 36,000 9.60 13.00 40,000 2.85 7.80 31,200 2.10 $238 $618
Mixed Ducted and Non-Ducted Indoor Units 3024382 37,000 10.40 13.65 41,000 2.875 7.95 30,400 2.05 $233 $520
XyMQ48MVJU
Non-Ducted Indoor Units 3024379 47,500 9.40 13.90 52,500 2.75 8.10 33,600 2.00 $294 $510
Ducted Indoor Units 3024381 48,000 9.00 13.10 54,000 2.60 7.85 36,400 2.00 $315 $614
Mixed Ducted and Non-Ducted Indoor Units 3024383 47,500 9.20 13.50 53,000 2.675 7.95 35,000 2.00 $303 $606
Certifed Perormanceollowing developments with the U.S. Department
Energy (DOE), the VRV-S systems are perormance
ertifed to ARI Standard 210/240 with the ollowing
erormance values:
UTDOOR UNITS - RXyMQ Hat Pump 3 Ton 4 Ton
Model RXYMQ36MVJU RXYMQ48MVJUCooling Capacity Btu/h 36,000 48,000Cooling Input Power kW 3.05 4.73Heating Capacity Btu/h 40,000 54,000Heating Input Power kW (Btu/h) 3.27 (11,157) 4.26 (14,535)Operating Range - Cooling F DB 23 - 115 23 - 115Operating Range - Heating F DB/F WB 0 - 64/-5 - 60 0 - 64/-5 - 60Power V/Ph/Hz 208-230/1/60 208-230/1/60Sound Pressure Level @3t dB(A) 58 58Airfow H/L cm 3,740 3,740Vertical Pipe Length t. 164 164
Actual Pipe Length t. 492 492Equivalent Pipe Length t. 575 575Total Pipe Length t. 1,000 1,000Weight lbs. 310 310Dimensions (H x W x D) in. 52 15/16 x 35 7/16 x 12 5/8 52 15/16 x 35 7/16 x 12 5/8