Page 1: VTAC 9 AC Drive Firmware Version 3.xx. Designed to Meet Worldwide Standards Agency Certification –Listed to UL508C and CAN/CSA-C2.2 –Listed to UL508C.

VTAC 9 AC DriveVTAC 9 AC Drive

Firmware Version 3.xxFirmware Version 3.xx

Page 2: VTAC 9 AC Drive Firmware Version 3.xx. Designed to Meet Worldwide Standards Agency Certification –Listed to UL508C and CAN/CSA-C2.2 –Listed to UL508C.

Designed to Meet Worldwide StandardsDesigned to Meet Worldwide Standards

• Agency Certification– Listed to UL508C and CAN/CSA-C2.2– Listed to UL508C for plenums– Marked for applicable European Directives

• Designed to meet the appropriate portions of the following specifications:– NFPA 70 – US National Electrical Code– NEMA ICS 3.1 – Safety standards for Construction and Guide for Selection,

Installation and Operation of Adjustable Speed Drive Systems– IEC 146 – International Electrical Code– Seismic requirements of the 2003 International Building Code as specified by

AC156

Page 3: VTAC 9 AC Drive Firmware Version 3.xx. Designed to Meet Worldwide Standards Agency Certification –Listed to UL508C and CAN/CSA-C2.2 –Listed to UL508C.

SpecificationsSpecifications

• Ratings:– 2-100HP (208V ac)– 3-200HP (480V ac)

• Short Circuit Rating:– 200,000Amps Symmetrical

• Efficiency:– 97.5% at rated amps, nominal line voltage

• Displacement Power Factor:– 0.98 across speed range

• Carrier (PWM) Frequency:– 2 to 10kHz (drive rating based upon 4kHz)

Page 4: VTAC 9 AC Drive Firmware Version 3.xx. Designed to Meet Worldwide Standards Agency Certification –Listed to UL508C and CAN/CSA-C2.2 –Listed to UL508C.

Control I/OControl I/O

2 – 25HP @ 208V ac

3 – 50HP @ 480V ac(frames B, C, D, E)

30 – 100HP @ 208V ac

60 – 200HP @ 480V ac(frames 4, 5, 6)

Digital Inputs(Run, Clear Fault, Enable, Purge, PI Enable, Etc.)

(6) Programmable, 24VDC (6) Programmable, 24VDC

Relay Outputs(Fault, Run, Ready, Alarm, At Speed, Current Limit, Etc.)

(2) Programmable Form C (2) Programmable Form C

Analog Inputs(Speed Reference, PI Feedback, Etc.)

(1) Non-Isolated (voltage or current)(1) Isolated, Bipolar (voltage or current)

(2) Isolated, Bipolar (voltage or current)

Analog Outputs(Output Freq, Output Amps, Output Power, PI Ref, Etc.)

(1) 0-10VDC (1) Bipolar +/-10V or 4-20mA

Page 5: VTAC 9 AC Drive Firmware Version 3.xx. Designed to Meet Worldwide Standards Agency Certification –Listed to UL508C and CAN/CSA-C2.2 –Listed to UL508C.

Hardware Features – FilteringHardware Features – Filtering

• EMC Filtering– Supplied with all ratings

– Internal Filter allows EN61800-3 Second Environment Levels to be met • Common Mode Filtering

– Common mode cores supplied with all ratings – help attenuate common mode noise– Common mode capacitors supplied with all ratings – provide low impedance path

Page 6: VTAC 9 AC Drive Firmware Version 3.xx. Designed to Meet Worldwide Standards Agency Certification –Listed to UL508C and CAN/CSA-C2.2 –Listed to UL508C.

World Class Motor ProtectionWorld Class Motor Protection

• Reflected Wave issues (also known as Standing Wave or transmission Line Effect) have been well documented in IGBT based drives

• This phenomenon can cause significant voltage peaks at the motor that present the possibility for insulation breakdown

• Rockwell Automation engineers have devoted years of research to develop industry-leading solutions for VTAC Drives– This has resulted in patented Software &

Hardware features that protect motors with long motor leads

– Each pulse is measured and controlled to avoid collisions with other reflected voltage pulses thus minimizing voltage amplification

– These solutions are supported with hundreds of hours of lab tests!

Page 7: VTAC 9 AC Drive Firmware Version 3.xx. Designed to Meet Worldwide Standards Agency Certification –Listed to UL508C and CAN/CSA-C2.2 –Listed to UL508C.

Hardware Features – Internal Bus InductorHardware Features – Internal Bus Inductor

• Provided with Every Rating: – 5HP and larger @ 208V ac– 7.5HP and larger @ 480V ac

• Supplied in pos. & neg. leg• Reduces Harmonics• Helps with transient

protection• Effective Impedance

– 3% (min) 7.5 - 50HP @ 480V ac– 5% (min) 60 - 200HP @ 480Vac

TDD - VTAC 9 vs. Leading Competitor

0.1

0.15

0.2

0.25

0.3

0.35

0.4

0.45

0 10 20 30 40 50 60

Motor Frequency at rated load (Hz)

Cu

rren

t d

isto

rtio

n (

TD

D)

TDD VTAC 9

Leading Competitor

THD VTAC 9 vs. Leading Competitor

0.00%

20.00%

40.00%

60.00%

80.00%

100.00%

120.00%

0 10 20 30 40 50 60 70

Motor Frequency at rated load (Hz)

Cu

rren

t D

isto

rtio

n (

TH

D)

VTAC 9

Leading Competitor

Page 8: VTAC 9 AC Drive Firmware Version 3.xx. Designed to Meet Worldwide Standards Agency Certification –Listed to UL508C and CAN/CSA-C2.2 –Listed to UL508C.

Operator KeypadOperator Keypad

• 5 Line LCD Keypad• Removable• Icon Based Programming• Multi-Language• Quick Start Feature• Password Protectable

Main Menu:

Diagnostics

Parameter

Device Select

0.00

F-> Stopped Ready A

Hz.

F Stopped Auto

- Fault - F05Overvoltage

Time Since Fault1:10:07

Main Menu:

Diagnostics

Parameter

Device Select

0.00

F-> Stopped Ready A

Hz.

F Stopped Auto

Fault Pop Up Parameter Edit

Page 9: VTAC 9 AC Drive Firmware Version 3.xx. Designed to Meet Worldwide Standards Agency Certification –Listed to UL508C and CAN/CSA-C2.2 –Listed to UL508C.

Operator KeypadOperator Keypad

Operating Status

Direction Indication

Menu, Programming Screen

Alarm Annunciation

Password Status

Auto / Hand Mode Status

Function Key Operation

Page 10: VTAC 9 AC Drive Firmware Version 3.xx. Designed to Meet Worldwide Standards Agency Certification –Listed to UL508C and CAN/CSA-C2.2 –Listed to UL508C.

Operator KeypadOperator Keypad

Horizontal Scroll Keys

Speed Control and Vertical Scroll Keys

Stop Key and Fault Reset

Start Operation

Enter Key

Escape / Program

Release Hand Reference Control

Configurable Function Keys

Enable Hand Reference Control

Page 11: VTAC 9 AC Drive Firmware Version 3.xx. Designed to Meet Worldwide Standards Agency Certification –Listed to UL508C and CAN/CSA-C2.2 –Listed to UL508C.

Main Menu Icons

Start-Up Parameters Control SourceSelect Diagnostics Display

1. Quickstart2. Input Voltage3. Motor Data4. Motor Tests5. Speed Limits6. Ref Setup7. Configure I/O8. Done

P Numbers Logic ControlRef Control

FaultsAlarmsReg VersionOIM VersionStatus Info

LanguageMonitorF KeysDrive IDDisplay Timeout

QS CSS

Device Select PasswordMemory

Reset DefaultsLoad from DriveLoad to DriveActive User Set

Keypad IconsKeypad Icons

Start Up Icon provides access to Quick Start Utility that allows for fast, easy set-up involving seven parameter groups.

Parameter Icon provides quick access to drive and peripheral component parameters.

Control Source Icon allows control and reference selection.

Diagnostic Icon provides information on faults and alarms.

Display Icon allows operators to configure the OIM for language, monitoring, function keys and other considerations.

Memory Icon allows operators to load and save different parameters sets into the OIM and, subsequently into the drive or to restore factory-set defaults.

Device Select Icon allows operators to identify and select the drive or peripheral device from which to obtain data.

Password Icon provides protection against modifications of all writable parameters by a unauthorized user and selects parameter access levels.

Icons provide users a intuitive interface as well as a logical method of grouping access to drive functions and operations

Page 12: VTAC 9 AC Drive Firmware Version 3.xx. Designed to Meet Worldwide Standards Agency Certification –Listed to UL508C and CAN/CSA-C2.2 –Listed to UL508C.

Programming – File, Group, ElementProgramming – File, Group, Element

Monitor************MeteringDrive Data

Motor Control****************Motor DataTorq AttributesVolts per Hertz

Speed Command*********************Spd Mode & LimitsSpeed ReferencesDiscrete SpeedsSpeed trimSlip CompProcess PI

Dynamic Control*********************Ramp RatesLoad LimitsStop/Brake ModesRestart ModesPower Loss

Utility*****************Reverse ConfigHIM ConfigMOP ConfigDrive Memory DiagnosticsFaultsAlarms

Communication*******************Comm ControlMasks & OwnersData Links

Inputs & Outputs*****************Analog InputsAnalog OutputsDigital InputsDigital OutputsPulse I/O

Page 13: VTAC 9 AC Drive Firmware Version 3.xx. Designed to Meet Worldwide Standards Agency Certification –Listed to UL508C and CAN/CSA-C2.2 –Listed to UL508C.

HVAC FeaturesHVAC Features

• Programmable Acceleration Time with S-Curve– Less mechanical stress on machinery and motors

• Skip Frequencies– 3 “Critical Avoidance” operating points– No continuous operation at these points

• Restart Modes– Line Loss – determines action after power is restored– Fault Conditions – Reset/Run allows certain faults to be automatically reset– Long Term Power Loss – Run on power-up

• Sleep-Wake Mode– Drive starts when analog signal greater than user-specified level

• PI Loop– Uses process feedback to compare against setpoint– Adjusts output Hz

Page 14: VTAC 9 AC Drive Firmware Version 3.xx. Designed to Meet Worldwide Standards Agency Certification –Listed to UL508C and CAN/CSA-C2.2 –Listed to UL508C.

HVAC FeaturesHVAC Features

• Flying Start– Reconnect to a spinning motor

• Shear Pin– Current limit adjustment for load and mechanical protection

• Purge Input– Overrides stop signal across network

• Intelligent Thermal Management– Carrier frequency reduction on overtemperature

• Electronic Motor Overload– Based on programmed motor FLA– Class 10 protection

Page 15: VTAC 9 AC Drive Firmware Version 3.xx. Designed to Meet Worldwide Standards Agency Certification –Listed to UL508C and CAN/CSA-C2.2 –Listed to UL508C.

TroubleshootingTroubleshooting

• Status LED– Flashing Green = Ready– Solid Green = Running

– Flashing Yellow = Start Inhibits– Solid Yellow = Alarm Condition Exists

– Flashing Red = Recoverable Fault– Solid Red = Non

Recoverable Fault

• Power LED• Viewable through the cover

Page 16: VTAC 9 AC Drive Firmware Version 3.xx. Designed to Meet Worldwide Standards Agency Certification –Listed to UL508C and CAN/CSA-C2.2 –Listed to UL508C.

Main Menu:DiagnosticsParameterDevice Select

0.00Auto

F-> Faulted

Hz.-- Fault-- F06M otor Stalled

Tim e since fault1:06:03

TroubleshootingTroubleshooting

• Alarms– User-Configurable: Alert operator of condition if left

untreated, may lead to fault condition– Non-Configurable: Alert operator of condition caused

by improper programming

• Faults– Auto-Reset/Run: Auto Restart can be used to attempt

to clear fault– Non-Resettable: Normally requires drive or motor

repair– User-Configurable: Enabled or disabled to annunciate

or ignore a fault

Page 17: VTAC 9 AC Drive Firmware Version 3.xx. Designed to Meet Worldwide Standards Agency Certification –Listed to UL508C and CAN/CSA-C2.2 –Listed to UL508C.

Drive Monitoring and Configuration SoftwareDrive Monitoring and Configuration Software

• V*S Utilities Software • Windows Explorer look and feel

– Left side tree view– Right side parameter list– HTML help

• Parameter Upload / Download– Configure parameter settings– Monitor I/O activity– Compare Files

• Monitor multiple drives when they’re on a communication network• Supported PC Operating Systems

– Windows 95/98/2000/NT

Page 18: VTAC 9 AC Drive Firmware Version 3.xx. Designed to Meet Worldwide Standards Agency Certification –Listed to UL508C and CAN/CSA-C2.2 –Listed to UL508C.

3 Contactor Full Feature Bypass with 3 Contactor Full Feature Bypass with DisconnectDisconnect

• Door interlock fused disconnect with Class J fuses– Some competitors offer disconnect switch which requires

upstream short-circuit branch protection• 100,000 AIC rating for direct connection to high capacity

power distribution lines– Some competitors offer circuit breaker which has AIC rating of 14-

20KA• 3 contactor bypass with Drive/DriveTest/Bypass modes

– Allows troubleshooting/programming of drive while in bypass– Some competitors offer 2 contactor bypass which does not allow

Drive to be electrically isolated should service be required• Bypass Control and Status Display provides quick visual

indication of drive/bypass status through LED’s and schematic diagram

• Class 20 motor overload protection in bypass circuit

Page 19: VTAC 9 AC Drive Firmware Version 3.xx. Designed to Meet Worldwide Standards Agency Certification –Listed to UL508C and CAN/CSA-C2.2 –Listed to UL508C.

• Single customer terminal block for all field wiring• Dedicated Purge Input for connection to fire and

life safety system• Switch for Hand/Off/Auto

– Hand = Keypad– Off = Off– Auto = Communication port or terminal block

• Remote activation of bypass

3 Contactor Full Feature Bypass with 3 Contactor Full Feature Bypass with DisconnectDisconnect

Page 20: VTAC 9 AC Drive Firmware Version 3.xx. Designed to Meet Worldwide Standards Agency Certification –Listed to UL508C and CAN/CSA-C2.2 –Listed to UL508C.

3 Contactor Full Feature Bypass with 3 Contactor Full Feature Bypass with DisconnectDisconnect

1

2

3

4

56

7

8

9

1

2

3

4

5

6

7

8

9

10

Bypass Control and Status Display

Bypass Control and Status Display Board

Drive Main Input Contactor

Drive Motor Output Contactor

Drive Bypass Contactor

Bypass Motor Overload Relay

115V AC Control Transformer

Field Control Wiring Terminal Block

Door Interlocked Main Input Disconnect

Main Input Disconnect Handle

10

Page 21: VTAC 9 AC Drive Firmware Version 3.xx. Designed to Meet Worldwide Standards Agency Certification –Listed to UL508C and CAN/CSA-C2.2 –Listed to UL508C.

Bypass Control and Status DisplayBypass Control and Status Display

• Hand/Off/Auto Selector Switch• Drive/Drive Test/Bypass Selector Switch• Status LEDs

– Ready– Interlock Open– Drive Output Enable– Purge– Bypass Trip– Bypass Run

Page 22: VTAC 9 AC Drive Firmware Version 3.xx. Designed to Meet Worldwide Standards Agency Certification –Listed to UL508C and CAN/CSA-C2.2 –Listed to UL508C.

Bypass ComponentsBypass Components

• Bypass Designs Utilize Rockwell Automation Industrial Components

• Disconnect Switch (Bulletin 194R)– Meets OSHA Lockout/Tagout– 100KA Fault Withstand Rating

• Contactors (Bulletin 100C)– Finger Safe– 3 Million manufactured per year– North American Market Leader for last 15 years (39% of

market share) • Overload Relay (Bulletin 193)

– Visible Trip Indication– Class 20 Overload Curve– Manual Reset with Test Button


Recommended