16 Wall-hung, high-power condensing premixed boilers TAHITI CONDENSING LINE TECH KR 55 Wall-hung, condensing, premixed boiler for central heating only, sealed chamber. Available with 58.8 kW output (50°C – 30°C). Pre-set to run on natural gas (can be transformed to run on propane). • High efficiency stainless steel heat exchanger. • Total premixing burner. • Modulating gas valve with constant air-to-gas ratio. • Variable speed combustion fan. • 3-speed circulation pump. • Air-purging device on heat exchanger. • Integrated air-purge bottle. • Differential (flow-return) and minimum water pressure switch. • Flame modulation. • Electronic ignition and flame sensing via ionization. • NTC immersion temperature probe on flow. • LCD interface with diagnostics. • Efficiency rating according to 92/42/CE: ★★★★ • NOx emission class (EN 297): 5 Available for connection to: • External cylinder for domestic hot water production (with anti-legionella and anti-frost function). • Open Therm Remote Control. • High and low temperature area heating management board. INCLUDED IN THE PRICE: Paper template, air sealing cap kit. 58.8 kW condensation heat exchanger Tahiti Condensing Mod. KR 55 Model Code Output in kW Efficiency at maximum output Gross weight TAHITI CONDENSING LINE TECH KR 55 NATuRAL GAS CTOxx2RR55 58.8 107.0 % Kg. 53 Control boards KR 55 2 boilers 3/4 boilers 5/6 boilers Standard electrical control board 0QUADCAS00 0QUADCAS01 0QUADCAS02 PC electrical control board 0QUADCAS10 0QUADCAS11 0QUADCAS12 GSM electrical control board 0QUADCAS05 0QUADCAS06 0QUADCAS07 Electrical control boards for cascade boiler management For the complete range of flue gas accessorieses see page 158 - 159 and for cascade systems see page 162- 163.
Transcript
Page 1: Wall-hung, high-power condensing premixed boilers Tahiti ... · Wall-hung, condensing, premixed boiler for central heating only, sealed chamber. available with 90.4 kW output (50°C

16

Wall-hung, high-power condensing premixed boilers

TahiTi CONDENSiNG LiNE TECh KR 55Wall-hung, condensing, premixed boiler for central heating only, sealed chamber.available with 58.8 kW output (50°C – 30°C).Pre-set to run on natural gas (can be transformed to run on propane).• High efficiency stainless steel heat exchanger.• Total premixing burner.• Modulating gas valve with constant air-to-gas ratio.• Variable speed combustion fan.• 3-speed circulation pump.• Air-purging device on heat exchanger.• Integrated air-purge bottle.• Differential (flow-return) and minimum water pressure

switch.• Flame modulation.• Electronic ignition and flame sensing via ionization.• NTC immersion temperature probe on flow.• LCD interface with diagnostics.• Efficiency rating according to 92/42/CE: ★★★★

• NOx emission class (EN 297): 5

Available for connection to:• External cylinder for domestic hot water production (with

anti-legionella and anti-frost function).• Open Therm Remote Control.• High and low temperature area heating management board.

INCLUDED IN THE PRICE: Paper template, air sealing cap kit.

58.8 kW condensation heat exchanger

Tahiti Condensing Mod. KR 55

Model Code Output in kW

Efficiency at maximum output

Gross weight

TAHITI CONDENSING LINE TECHKR 55

NATuRAL GAS CTOxx2RR55 58.8 107.0 % Kg. 53

Control boards KR 55 2 boilers 3/4 boilers 5/6 boilersStandard electrical control board 0QUaDCaS00 0QUaDCaS01 0QUaDCaS02PC electrical control board 0QUaDCaS10 0QUaDCaS11 0QUaDCaS12GSM electrical control board 0QUaDCaS05 0QUaDCaS06 0QUaDCaS07

Electrical control boards for cascade boiler management

For the complete range of flue gas accessorieses see page 158 - 159 and for cascade systems see page 162- 163.

Page 2: Wall-hung, high-power condensing premixed boilers Tahiti ... · Wall-hung, condensing, premixed boiler for central heating only, sealed chamber. available with 90.4 kW output (50°C

17

450

750

3050

534

4356 173 98 80

220.5

127

62

14813589 78

G MF

R

S

G Gas inlet (3/4”)M CH system flow (1”)F Domestic cold water inlet (1/2”)R CH system return (1”)S Condensate drain

top view

bottom view

Dimensions and coupling centre distances

Tahiti Condensing Mod. KR

For the complete range of flue gas Accessorieses see page 158 - 159 and for cascade systems see page 162- 163.

a T T E N Z i O N E :

Questa caldaia utilizza la fumisteria per le caldaie a condensazione oppure la fumisteria per gli impianti a cascata disponibile a pag. 162 - 163.

Accessoriesesitem Description Code

Ø 60/100 0.75 m long coaxial kit 0CONDaSP00

Ø 60/100 coaxial coupling kit 0KiTaTCO00

Ø 60/100 90° elbow and flange kit 0KCURFLa00

Ø 80+80 split pipe kit 0KiTSDOP00

Remote control 0CREMOTO05

External probe 0SONDaES01

Electric kit for zone management complete with external probe 0KiTZONE00

Temperature probe for cylinder 0KiTSOND00

Paper fixing template 0DiMaCaR12

Boiler cover 0COPERiG01

Page 3: Wall-hung, high-power condensing premixed boilers Tahiti ... · Wall-hung, condensing, premixed boiler for central heating only, sealed chamber. available with 90.4 kW output (50°C

18

1110

9

8

7

6

5

4

3

2

1

12

13

14

15

16

17

18

19

G MS F R

Tahiti Condensing Line Tech Mod. KR 55 hydraulic layout

head available for boiler (by-pass closed)

1 Condensate drain siphon 2 Modulating gas valve 3 Safety thermostat 4 Modulating fan 5 Condensing primary heat exchanger 6 Ignition electrode 7 Air-purging device 8 Combustion air intake system 9 Flue gas discharge system10 Flue gas analysis point11 Flue gas thermostat12 Central heating temperature probe13 Detection electrode14 Fan control sensor15 Air-purging device16 Circulation pump17 Minimum/differential pressure switch18 unloading tap19 Loading tap

S Condensate drainG Gas inletM CH system flowF Cold water inletR CH system return

V1

V2

V3

Mod. KR 55

600

700

800

400

500

200

300

0

100

0 500 1000 1500 2000 2500

mb

ar

l/h

Page 4: Wall-hung, high-power condensing premixed boilers Tahiti ... · Wall-hung, condensing, premixed boiler for central heating only, sealed chamber. available with 90.4 kW output (50°C

19

TEChNiCaL SPECiFiCaTiONS KR 55

Gas category II2H3P

Nominal heat input kW 55.0

Nominal heat output (80-60°C) kW 53.5

Nominal heat output (50-30°C) kW 58.8

Minimum heat output (80-60°C) kW 14.1

Minimum heat output (50-30°C) kW 15.7

useful efficiency at nominal heat input (80-60°C) % 97.3

useful efficiency at nominal heat input (80-60°C) % 97.0

useful efficiency at nominal heat input (50-30°C) % 107.0

useful efficiency at minimum heat input (50-30°C) % 108.1

useful efficiency at 30% % 108.9

Casing heat loss with burner on at nominal heat input % 0.46

Casing heat loss with burner on at minimum heat input % 0.83

Casing heat losses with burner off % 0.36

Chimney heat loss with burner on at nominal heat input % 2.04

Chimney heat loss with burner on at minimum heat input % 1.89

Energy efficiency mark (92/42 EEC) ★ ★ ★ ★

NOx class (EN 297/EN 483) 5

Maximum working pressure bar 4

Maximum working temperature °C 83

Temperature adjustment °C 20 - 78

Central heating consumption at nominal heat output (80-60°C) Natural gas m3/h 5.82

Central heating consumption at minimum heat output (80-60°C) Natural gas m3/h 1.534

Central heating consumption at nominal heat output (80-60°C) Propane kg/h 4.26

Central heating consumption at minimum heat output (80-60°C) Propane kg/h 1.124

ΔT flue gas/air at nominal heat input °C 44

∆T flue gas/air at minimum heat input °C 39

Flue gas flow rate at nominal heat input g/s 25.1

Flue gas flow rate at minimum heat input g/s 6.6

CO2 at nominal heat input Natural gas % 9.0

CO2 at nominal heat input Propane % 10.0

Residual available head at nominal heat input Pa 290

Residual available head at minimum heat input Pa 23

Supply pressure Natural gas mbar 20

Supply pressure Propane mbar 37

Diaphragm diameter Natural gas mm 8.2

Diaphragm diameter Propane mm 5.9

Power supply voltage/frequency V/Hz 230/50

Fuse on the power supply A 2

Absorbed electric power W 245

Electric protection rating IPX4D

Gas fitting G3/4

Central heating fittings G 1

L x H x D mm 450x750x534

Gross weight kg 53

Net weight kg 51.4

Page 5: Wall-hung, high-power condensing premixed boilers Tahiti ... · Wall-hung, condensing, premixed boiler for central heating only, sealed chamber. available with 90.4 kW output (50°C

20

Wall-hung, high-power condensing premixed boilers

TahiTi CONDENSiNG LiNE TECh KR 85Wall-hung, condensing, premixed boiler for central heating only, sealed chamber.available with 90.4 kW output (50°C – 30°C).Pre-set to run on natural gas (can be transformed to run on propane).• High efficiency stainless steel heat exchanger.• Total premixing burner.• Modulating gas valve with constant air-to-gas ratio.• Variable speed combustion fan.• 3-speed circulation pump.• Air-purging device on heat exchanger.• Integrated air-purge bottle.• Differential water pressure switch (flow-return) and mini-

mum.• Flame modulation.• Electronic ignition and flame sensing via ionization.• NTC immersion temperature probe on flow.• LCD interface with diagnostics.• Efficiency rating according to 92/42/CE: ★★★★

• NOx emission class (EN 297): 5

Available for connection to: • External cylinder for domestic hot water production (with

anti-legionella and anti-frost function).• Open Therm Remote Control.• High and low temperature area heating management board.

Tahiti Condensing Mod. KR 85

Model Code Output in kW

Efficiency at maximum output

Gross weight

TAHITI CONDENSING LINE TECHKR 85

NATuRAL GAS CTOxx2RR85 90.4 106.4 % Kg. 77

Control boards KR 85 2 boilers 3/4 boilers 5/6 boilersStandard electrical control board 0QUaDCaS00 0QUaDCaS01 0QUaDCaS02PC electrical control board 0QUaDCaS10 0QUaDCaS11 0QUaDCaS12GSM electrical control board 0QUaDCaS05 0QUaDCaS06 0QUaDCaS07

Electrical control boards for cascade boiler management

For the complete range of flue gas Accessorieses see page 160 - 161 and for cascade systems see page 162- 163.

INCLUDED IN THE PRICE: Paper template, kit tronchetto aspirazione aria Ø 80 мм. con tappo di chiusura.

accessorieses supplied with the boiler included in the price:

Tronchettoaspirazione aria

Ø 80 mm.

Page 6: Wall-hung, high-power condensing premixed boilers Tahiti ... · Wall-hung, condensing, premixed boiler for central heating only, sealed chamber. available with 90.4 kW output (50°C

21

62

750

450

5042

534

43 56 173 98 80

220.

5

S

SIG

M F

R

RC

89 135 148 78

127

Ø100 mm �ue gasdischarge

Ø80 mm air intake

G Gas inlet (3/4”)M CH system flow (1”)F Domestic cold water inlet (1/2”)R CH system return (1”)S Condensate drain

top view

bottom view

Dimensions and coupling centre distances

Tahiti Condensing Mod. KR

For the complete range of flue gas Accessorieses see page 160 - 161 and for cascade systems see page 162- 163.

Accessoriesesitem Description Code

Remote control 0CREMOTO05

External probe 0SONDaES01

Electric kit for zone management complete with external probe 0KiTZONE00

Temperature probe for cylinder 0KiTSOND00

Paper fixing template 0DiMaCaR12

Boiler cover 0COPERiG01

a T T E N Z i O N E :

Questa caldaia uti l iz za scarichi sdoppiati con aspirazione aria Ø 80 мм. e scarico fumi Ø 100 мм. oppure la fumisteria per gli impianti a cascata disponibile a pag. 162 - 163.

Page 7: Wall-hung, high-power condensing premixed boilers Tahiti ... · Wall-hung, condensing, premixed boiler for central heating only, sealed chamber. available with 90.4 kW output (50°C

22

G MS F R

1

2

34

5

67

8

9

11

10

12

13

14

1516

17

Tahiti Condensing Line Tech Mod. KR 85 hydraulic layout

1 Condensate drain siphon 2 Modulating gas valve 3 Modulating fan 4 Safety thermostat 5 Condensing primary heat exchanger 6 Ignition electrode 7 Central heating temperature probe 8 Flue gas discharge system 9 Air-purging device10 Flue gas thermal fuse11 Detection electrode12 Air-purging device13 Fan control sensor14 Circulation pump15 unloading tap16 Minimum/differential pressure switch17 Loading tap

S Condensate drainG Gas inletM CH system flowF Cold water inletR CH system return

head available for boiler (by-pass closed)

mb

ar

Mod. KR 85

600

700

800

900

400

500

200

300

0

100

0 500 1000 1500 2000 2500 2500 3000 3500 4000 4500

l/h V1

V2

V3

Page 8: Wall-hung, high-power condensing premixed boilers Tahiti ... · Wall-hung, condensing, premixed boiler for central heating only, sealed chamber. available with 90.4 kW output (50°C

23

TEChNiCaL SPECiFiCaTiONS KR 85

Gas category II2H3P

Nominal heat input kW 85.0

Nominal heat output (80-60°C) kW 82.7

Nominal heat output (50-30°C) kW 90.4

Minimum heat output (80-60°C) kW 20.3

Minimum heat output (50-30°C) kW 22.6

useful efficiency at nominal heat input (80-60°C) % 97.3

useful efficiency at nominal heat input (80-60°C) % 97.3

useful efficiency at nominal heat input (50-30°C) % 106.4

useful efficiency at minimum heat input (50-30°C) % 107.7

useful efficiency at 30% % 108.5

Casing heat loss with burner on at nominal heat input % 0.30

Casing heat loss with burner on at minimum heat input % 0.93

Casing heat losses with burner off % 0.48

Chimney heat loss with burner on at nominal heat input % 2.20

Chimney heat loss with burner on at minimum heat input % 1.79

Energy efficiency mark (92/42 EEC) ★ ★ ★ ★

NOx class (EN 297/EN 483) 5

Maximum working pressure bar 4

Maximum working temperature °C 83

Temperature adjustment °C 20 - 78

Central heating consumption at nominal heat output (80-60°C) Natural gas m3/h 9.0

Central heating consumption at minimum heat output (80-60°C) Natural gas m3/h 2.222

Central heating consumption at nominal heat output (80-60°C) Propane kg/h 6.59

Central heating consumption at minimum heat output (80-60°C) Propane kg/h 1.628

ΔT fumi/aria allat nominal heat input °C 47

∆T flue gas/air at minimum heat input °C 36

Flue gas flow rate at nominal heat input g/s 38.7

Flue gas flow rate at minimum heat input g/s 9.6

CO2 at nominal heat input Natural gas % 9.0

CO2 at nominal heat input Propane % 10.0

Residual available head at nominal heat input Pa 240

Residual available head at minimum heat input Pa 19

Supply pressure Natural gas mbar 20

Supply pressure Propane mbar 37

Diaphragm diameter Natural gas mm 10.3

Diaphragm diameter Propane mm 7.9

Power supply voltage/frequency V/Hz 230/50

Fuse on the power supply A 2

Absorbed electric power W 245

Electric protection rating IPX4D

Gas fitting G3/4

Central heating fittings G 1

L x H x D mm 450x750x534

Gross weight kg 77

Net weight kg 75.2