Date post: | 31-Mar-2015 |
Category: |
Documents |
Upload: | lillie-eddings |
View: | 215 times |
Download: | 2 times |
Washington Laboratories (301) 417-0220 web: www.wll.com 7560 Lindbergh Dr. Gaithersburg, MD 20879
EMC Fundamentals
Presented By:Mike Violette
Washington Laboratories, Ltd.September 14, 2007
http://www.wll.com
IntroductionElements of an EMI Situation
• Source "Culprit"• Coupling method "Path"• Sensitive device "Victim"
SOURCEPATH
VICTIM
http://www.wll.com
Let’s see how this all got startedDead Smart Guys
• First Transmitters: Spark Devices• Heinrich Hertz (1857-1894) clarified
and expanded on• James Clerk Maxwell’s
Electromagnetic Theory
• Marconi: first use & patent
HertzMaxwell
Marconihttp://www.wll.com
How Does EMI Affect Electronics?• Radiated and conducted interference
• Conducted Interference Enters and Exits Equipment through Wiring and Cabling
• Radiated Interference Enters and Exits Equipment through Wiring and Enclosure Penetration
Radiated Susceptibility Radiated Emissions
Conducted Susceptibility Conducted Emissions
http://www.wll.com
Interference to TV Reception
Two Interfering Signals Injected into TV
No Interference
http://www.wll.com
Common “Coupling Modes”
Common and Differential Mode• Crosstalk (cabling and conductors)• Field to cable (“Antenna”)• Conducted (direct)• Field to enclosure
http://www.wll.com
Radiated Coupling: Field to Cable
Loop Area
Induced Current
Electromagnetic Wave
Coupling proportional to: E/H Field, Loop Area, Frequency
http://www.wll.com
COMMON and DIFFERENTIAL MODE• COMMON-MODE: “Line to Ground”• DIFFERENTIAL MODE: “Line-to-Line” (Normal
Mode)
VC
M
VDM
INoise
http://www.wll.com
Radiated Coupling: Field to Cable
Patient Monitor
Loop AreaInduced Current
Electromagnetic WaveRadio
VC
M
http://www.wll.com
Instrumentation Interference
Interference Current, If
Ideal Response
Frequency (Hz)
EKG Signal
Real Response
Frequency (MHz)
NOISE
http://www.wll.com
How Does EMI Affect Electronics?• Electrostatic Discharge & Transient Pulses• ESD can induce “glitches” in circuits, leading
to false triggering, errors in address & data lines and latch-up of devices
• Upset• Damage• Degradation leading to future failure(s)
Gee, the humidity is low in here.
What’s this for?
http://www.wll.com
Filtering
Interference Current
EKG Signal
C
C
Interference Current
EKG Signal
Please, I’m very ticklish
http://www.wll.com
Surge Coupling• Lightning and pulse sources cause high-energy transients
into power and data cables
IndirectDirect
http://www.wll.com
Digital Equipment SourcesFourier Analysis
F(t)Log Ff =
1/T2f 3f
T
A
Spectrum of a Square Wave
T
A
Log F
F(t)f =1/
f =1/r
r
Spectrum of a Trapezoidal Wave(Characteristic of Digital Devices)
http://www.wll.com
Equipment Emissions Limits
Emissions Limits @ 3 meters
0
10
20
30
40
50
60
70
10 100 1000 10000
Frequency (MHz)
dB
uV
/m
FCC B CISPR B
FCC A
CISPR A
http://www.wll.com
The decibel (dB)
• The dB is used in Regulatory Limits (FCC, CISPR, etc.)• The dB is a convenient way to express very big and very small
numbers• The “Bel” was named after Alexander Graham Bell
Bel = LOG10(P2/P1)• deciBel provides a more realistic scale:
dB = 10LOG10(P2/P1)• Voltage & Current are expressed as follows:
dB (V or I) = 20LOG10(V2/V1)
“20LOG” derives from the conversion from Power to Voltage (ohm’s Law: P = E2/R)
Named after me!
http://www.wll.com
dB• Can have several reference units:
• Watt: dB above one Watt (dBW)• Milliwatt: dB above one milliwatt (dBm)• Volt: dBV• Microvolt: dBuV• Microamp: dBuA• picotesla: dBpT• Electric Field: dBuV/m
• Radio Receiver Sensitivity ~ 10 dBuV• E-Field Limit for FCC: ~40-60 dBuV/m• Distance to moon: 107dBmile (20LOG2.5E+5miles)• National debt: 128dB$ (10LOG6E+12)
http://www.wll.com
Broadband Sources
• Man-made noise dominates• Intended transmissions, switching transients, motors, arcing• Intermittent operation of CW causes transient effects
• Digital Switching• Inductive kick• Switch bounce
• Digital Signaling• Broad spectrum based on pulse width & transition time• HDTV• CDMA• UWB Technologies
http://www.wll.com
Pulsed SourcesFourier Analysis
A
F(t)
Spectrum of a Pulse
Log Ff =1/
f =1/r
r
Fourier->
Do you like my new shirt?
http://www.wll.com
Cables - Overview• Major coupling factor in radiating emissions from an equipment and coupling of emissions
from other sources into an equipment• Acts as radiating “antenna”, receiving “antenna”, and cable-to-cable coupling mechanism• External cables are not typically part of the equipment design but the installation
requirements must be considered during the design• Problem is a function of cable length, impedance, geometry, frequency of the signal and
harmonics, current in the line, distance from cable to observation point• Frequency Effects: Tied into Cable Wavelength
• For example, wavelength at FM Radio Band (100 MHz) is 1 meter (Human Body Resonance)
= c/f = 3X108/frequency = 300/fMHz
http://www.wll.com
Cables - Length/Impedance• Efficiency as an antenna - function of length compared to
wavelength• At typical data transfer rates - length is short• At harmonics or spurs the length may become long• Impedance mismatch creates a high SWR
http://www.wll.com
How very important
• Frequencies of testing from 26 MHz to 1 GHz• Corresponding cable lengths:• L ~ 11 meters @ 26 MHz to 30 cm @ 1 GHz• “Short” cables can be large contributors to Interference
Problems• Power cables• Grounding wires• Patient cables• Data cables• Control harnesses• Structures!
http://www.wll.com
Cables - Loops• Emissions are a function of 1) Current; 2) Loop Geometry; 3) Return Path of the
Current• Current flow creates a magnetic field H=I/2R for a single wire model
• Single wire case is not realistic• Loop geometry formed by the current carrying conductor and the return line
contribute to the field strength• Electric field strength:
E f AI
RV m MHz cm
amps
meters( / ) ( ) ( )
( )
( )
. * *13 22
V ~
I
Area
E (& H)
http://www.wll.com
Filters - Overview• Passband• High pass• Low pass• Single component, L, Pi, T• Common mode; differential mode• Placement• Components• Lead length• Leakage Limitations
http://www.wll.com
Low Pass Filter
Noise Current
EKG Signal
C
C
Noise Current
EKG Signal
Frequency (Hz)
Rejection
EKG Signal
Noise
Attenuation of Noise
http://www.wll.com
Filters - Components
• Discrete Component Filters• Component selection• Lead length considerations
• Power Filter Modules• Filtered Connectors
• Construction• Selective loading
• Termination (bonding and grounding)
http://www.wll.com
FiltersPower Line Filter Typical Schematic
Signal Line Filter(Screw-in Type)
Signal Line Filter
http://www.wll.com
Filter - Placement• Isolate Input & Output
• Establish boundaries with filters between• Input or Output interfaces and active circuitry• Digital and Analog• Compartments and Modules
• Prevent bypass coupling• Control line exposure on line side of filter• Use dog-house compartment• Shielded cables to control exposed cable runs
• Terminate - Terminate - Terminate• Low impedance to ground termination• Minimize lead length
http://www.wll.com
Filter PerformancePoor Installation =Poor Performance
Filter
Filter INFilter OUT
http://www.wll.com
Shield Concepts
+ -
Field Terminations on Inside
Metal Sphere“Faraday Cage”
“Ground” 0V Potential
V+
V=0
+ -Electric Field Coupling
E-FieldV+
http://www.wll.com
Shield Concepts
Magnetic Field Shielding
Common at powerline and low frequencies; High-current conditions
I
V
Ferrous Shield
Low residual field
Magnetic Field Coupling
V
I
http://www.wll.com
Effects of Openings
+ -
Metal Sphere“Faraday Cage” V=0
V+
V=?
Cable Leakage
+
http://www.wll.com
RF Leakage
VRF~
Metal Box
RF Source
L
L ~ /2Perfect Transmission
http://www.wll.com
Shielding - Overview
• Shields - conductive barriers• Reflection• Absorption
• Materials• Electric field - conductivity• Magnetic field - permeability
• Discontinuities• Windows• Vents• Seams• Panel components• Cable connections
http://www.wll.com
Shielding Effectiveness
SHIELD
Incident Field E1 Resultant Field E2
SE = E2/E1 (dB)
Reflected ER
http://www.wll.com
Shielding - Reflection/Absorption
RR fE dBmeters Hz
( )( ) ( )
log(* *
) 322 10 2 3
Rf R
H dB
Hz meters
( )
( ) ( ). log(
* *) 14 5 10
2
R fP dB Hz( ) ( )log( * ) 168 10
A k t fdB Hz( ) ( )* * * *
Plane wave occurs when E to H wave impedance ratio = 1
f RMHzmeters
( )( )
3002
k = 3.4 for t in inches and k = 134 for t in meters
http://www.wll.com
Shielding - Material
Metal Conductivity - Permeability -
Silver 1.05 1Copper 1 1Gold 0.7 1
Aluminum 0.61 1Zinc 0.29 1Brass 0.26 1Nickel 0.2 1
Iron 0.17 1000Tin 0.15 1
Steel 0.1 1000Hypernick 0.06 80000
Monel 0.04 1Mu-Metal 0.03 80000
Stainless Steel 0.02 1000
All are good electric field shields Need high u for Mag Field Shield
http://www.wll.com
Shielding - Seams/Gaskets
• Required openings offer no shielding in many applications• Apertures associated with covers tend to be long or require
many contact points (close screw spacing)• Large opening treatment
• Screens, ventilation covers, optic window treatments• WBCO formed to effectively close opening
• Seam opening treatments• Overlapping flanges• Closely spaces screws or weld• Gasket to provide opening contact• Gasketed SE
SE a LdB cm( ) ( ).log( * ) 115 10 1 2 SE a LdB in( ) ( )
.log( * ) 99 10 1 2
http://www.wll.com
Shielding - Penetration
• Conductors penetrating an opening negates the shielding provided by absorption and reflection
• Cables penetrations require continuation of the shield or• Conductors require filtering at the boundary
• Cable shields require termination• Metal control shafts serve as a conductor
• Use non-metallic• Terminate shaft (full circle)
http://www.wll.com
Grounding - Overview
• Purpose• Safety protection from power faults• Lightning protection• Dissipation of electrostatic charge• Reference point for signals
• Reference point is prime importance for EMC• Potential problems
• Common return path coupling• High common impedance• High frequency performance
http://www.wll.com
Grounding - Impedance
• Establish a low impedance return• Ground planes• Ground straps for high frequency performance
• Establish single point or multipoint ground• Single point for low frequency or short distance
• Distance(meters) < 15/f(MHz)
• Multipoint for high frequency or long distance
• Distance(meters) > 15/f(MHz)
http://www.wll.com
Bonding
• Bonds should have two basic characteristics• Low impedance < 2.5 milliohms• Mechanical & electro-chemical stability
• Low impedance• Avoid contamination• Provide for flush junction to maximize surface contact• Use gaskets or fingerstock for seam bonds• Provide a connecting mechanism
• Mechanical and electro-chemical stability• Torque to seat for the mechanical connection• Lock washers to retain bond• Allow for galvanic activity for dissimilar metals
http://www.wll.com
Galvanic Scale
http://www.wll.com
Component Selection
T
A
Log F
F(t)f =1/T
2f 3f
T
A
Log F
F(t)f =1/
f =1/r
r
Spectrum of a Square Wave
Spectrum of a Trapezoidal Wave(Characteristic of Digital Devices)
http://www.wll.com
Circuit Design – Component Selection
• Circuits available in an EMI version• Specify logic of necessary speed - not faster than required• EMI performance varies between manufacturers
MAX485 MAX487
EMI V dVdt *
http://www.wll.com
Switching Power Supplies
• Two Sources:• Harmonics of switching power supply• Broadband emissions due to ringing
waveforms
&f
f
http://www.wll.com
Underdamped (Ringing) Waveform
• Typical in switching circuits
f100 MHz+
100sVolts
10s kHz
dV/dT = 100sMV/s
Broadband (radiated & conducted)
http://www.wll.com
Circuit Design - Summary
• Consider EMI at the beginning• Understand requirements• Select components• Design in protection
• Circuit Design - Layout• Design in ground planes, guards, segregation• EMI gains from layout has virtually zero recurring cost
• Grounds and Returns• Develop a ground scheme• Consider digital, analog, return, and shield terminations
• Design in hooks• Provide space for potential fix actions that may be required
http://www.wll.com
Decoupling &Power Distribution
• Connect all ground pins of high frequency circuits together in the same ground structure.
• Do not separate, isolate, break or otherwise “cut” the ground plane.
• Do not separate, isolate, break or otherwise “cut” the power plane.
• Do not insert impedances into Vcc/power traces.
http://www.wll.com
Isolated Power/Grounding
• Example Trace Layout (Bad Idea!)
Exception: Analog circuit isolation
http://www.wll.com
Top 10 Common Mistakes
1. Improperly shielded cables: The principal problem is the cable-to-backshell termination
2. Unfiltered cable penetrations3. High Frequency sources with poor termination:
High frequency sources: signals and power supplies
4. Case seams and apertures: bad/no gasket, or improper mating surfaces
5. Poor bonding between metal parts of unit
http://www.wll.com
Top 10 Common Mistakes
5. Long ground leads on shields and bonding conductors
6. No high frequency filtering on analog inputs: Radiated and conducted immunity
7. Not accounting for the high frequency effects of ESD
8. Inadequate filters on I/O cables for emissions9. Inadequately-installed power line filters
http://www.wll.com
The Ten Steps toAvoiding EMI Problems
1. Signal Termination2. Layout3. Decoupling & Power
Distribution4. Grounding5. Bonding
6. Filtering
7. Cabling
8. Shielding
9. Surge Suppression
10. CHECKLIST
http://www.wll.com
CHECKLIST
Signal Termination RC Terminations (33 ohms + 27 pF) on
periodic signals Group high frequency sources together;
minimize trace runs of high frequencysignals
Don’t source/sink I/O (whether internal orexternal) through high frequency devices
Position oscillators and crystals away fromI/O and openings in the chassis
Snub switching power supply waveforms tominimize HF energy
Decoupling & Power Distribution Connect all ground pins of high frequency
circuits together 0V reference (bond 0V to chassis) Solid power and Ground planes No impedances in Vcc/power traces.
Bonding Checklist Bond 0V to chassis ground Bond 0V to connector frames and shells Bond connector frames to chassis Bond metal frames together
Filtering Filters are installed at enclosure wall LC filter on unshielded cables Plan for capacitor on shielded lines
Cabling Route cables to avoid coupling Use only fully-shielded cables Fully-terminate shield grounds to
metal/metalized connector shels Terminate shells to chassis
Shielding The Business Card Test Use correctly-rated suppressor line-to-line
and line-to-ground Gas Tubes Varistors SAD (Silicon Avalanche Diodes)
http://www.wll.com