HAWS COMPACT WALL-MOUNTED WATER COOLERS
Models HWS4, HWS8, HWS13
Compact wall mounted models aredesigned to leave the floor free foreasy cleaning and only extend W/%"from the wall. A variety of colorfinishes give the specifier the abilityto complement the building decor.CABINETManufactured of heavy-gauge steelwith vinyl protective coating on thefront and sides. Resistant to wear,moisture, perspiration, heat and sun-light. Also available in stainless steeland stainless steel with SiennaBronze finishCOOLER TOPAnti-splash ridge reduces splatter.Contour design ensures properdrainage and prevents standingwaste water. Stainless steel top withbright finish resists stains and cor-rosion and is easy to maintain.BUBBLEROne:piece, chrome-plated, shielded,anti-squirt, angle stream designed tbprevent contamination from otherusers and air-borne deposits.VALVE/STREAM REGULATORThe self closing push buttonoperated combination valve and
screwdriver adjusted regulator is lo-cated inside cabinet to preventtampering. A constant stream heightis automatically maintained underlime pressures that vary from 20 to150 PSl.EVAPORATOR/CHILLER WATERDesign combines counterflow cool-ing with efficient bonding of therefrigerant and water coils for maxi-mum heat transfer. All-copper con-struction meets government andcommercial sanitation requirements.PRECOOLER(Models HWS8 & HWS13 Only)Increased efficiency boosts capacityby 60%. Double-wall constructionhas incoming water line coiledaround and bonded to cold waterdrain line. 1" (approx.) free-flow areathroughout drain line reduceschance of clogging.TEMPERATURE CONTROL. -Positive' sensing thermostat for con-trolling temperature of evaporator/chiller storage water. It is factory set50T. Adjustable 5T .
Standard Finish is Sahara Vinyl.OPTIONAL FINISHES Almond Vinyl Walnut Vinyl Stainless Steel (Extra Cost)Q Stainless Steel with Sienna
Bronze finish. Add "B" tomodel number (Extra Cost.)
FAN MOTORUnit bearing self-lubricating type formaintenance-free longer life.CONDENSERCopper/aluminum construction.INSULATION SYSTEMEvaporator/chiller employs totally en-capsulated construction of high ef-ficiency EPS for maximum insulatingcharacteristics.REFRIGERATION SYSTEMSystem balance, lower energyusage, and longer life assured byutilizing high displacement compres-sor, counterflow cooling evaporator/chiller, efficient capillary sizing, largecapacity dryer-strainer, fan-cooledcondenser with maximum heat ex-change. Hermetically sealed, posi-tive start compressor with lifetimelubrication and built-in overloadprotection. System completelysealed after deep evacuation,
'dehydration, and pressure testingat 250 PSIG.
WATER COOLERSHAWS DRINKING FAUCET COMPANY 33
HEIDEMANNIngenir & Handelsfirma ApS Telefon (+45) 98 42 20 30Sndergade 242 9900 Frederikshavn
FarText BoxIMO 9146455L163
HAWS COMPACT WALL-MOUNTED WATER COOLERS
Models HWS4, HWS8, HWS13r
MOUNTING INSTRUCTIONSMount trap and hanger bracket andinstall union connection/service stopto building supply line. To ensureproper engaging of waste line intotrap, center line of trap must be 77/8"from wall face. Remove slip nut andgasket from trap and install on wasteline tube. Hang cooler on bracketand engage waste line tube into trapinlet. Centerline height of waste out-let is 31VV from floor line for conven-tional adult installation. A servicestop (not furnished) is recommendedand 4" clearance on sides of unit forproper air circulation.ELECTRICALFurnished with plug-in, 3-wiregrounding type service cord; 120volt, 60 Hz, single phase.PLUMBING CONNECTIONS '-Waste: 1V4" OD tailpiece.Supply:W FPT combination inlet fit-
ting and strainer.OPTIONAL ACCESSORIES(Extra Cost) Cold water giassfiller (specify
model), mounted on left rear. For,more information, see page 75.
7(378J_
__-HANGERBRACKET
[Ilt DITAII-A]WATER INLET 1STAIN ER 3/8"STD.FEMALE PIPE THD.
RECOMMENDED HEIGHTADULTS 0-1/3 005?)YOUNGSTERS 33-1/2 (?51)
FROM FLOOR LINE6 HOLES,] EA. ENDJjft DIA.
H3130 H3140
/
fi
FRONT VIEW
HANGER BRACKET
ORAIN PIPE l j O DSUP JOINTCONNECTION
WATE SUPPLY LINE
DRAIN TRAP -[^NOT fUlNUHID]..
SHUT-OFF VALVE
ALTERNATE LOCATION4- FOR DRAIN TRAP AND
WATER SUPPLY LINE
DETAIL-A
ModelNumberHWS4HWS8HWS13
Com
pres
sor
Size
&
Cond
ensin
gM
edium
Ve AIRVe AIRMs AIR
Wat
t Usa
ge
249246395
toQ.
3.73.7
Cold
Wat
er
jGi
assfi
ller
Optio
n
j
//
4.7 I /
220V
-50
Hz Op
tion
j
//
H x W x D(in inches)Shipoing
Dimensions
25X18X1925X18X 1925X18X19
Shipp
ing
jW
eight-
Ibs.
j
596164
Cubic
Fe
et
4.94.94.9
r
INLETWATER
AmblenlTemperature
HWS4
HWS8
HWS13
70T (21'C)70'F
(21X)79127
20 6
80'F(27-C)
76121
19 7
90'F(32X)
I 70
112
182
100T(38X)62103164
l-80T(2TC) .>7O'F
(21-C)569.1147
80T(27-C)
54
87
14 0
OTf(32-C)
5.0"
8.0
13 0
100'F(38-C)
45
72
117
90'F (32-)7O'F
(21-C)42
68
80T(27-C)
40
90'F(32-C)
336 5 . 50
110 | 10.5 97
100T(38'C)3454
BaseRate
50
8 7 I 80GPH dnnking water delivered at 50'F (10'C) based on 60% spill through pre-cooler.
To convert inches to centimeters multiply inches by 2.54. To convert gallons to liters multiply gallons by 3.785.
ALL WATER-BEARING MATERIALS COMPLY WITH THE SAFEDRINKING WATER ACT OF 1986 AND THE LEAD CONTAMINATIONCONTROL ACT OF 1988.
WARRANTYFive-year warranty protects refrigeration system. Ask for cur standardwarranty policy detailing our complete and specific liabilities.
UL listed and certified by ARI to meet Standard 1010-84Note: Continued product improvement makes specificationssubject to change without notice.
H3139 H3105r
WATER COOLERS34 HAWS DRINKING FAUCET COMPANY
1435 4th Street P.O. Box 1999Berkeley, CA 94701 Telex 33-6358Phone: (415)525-5801FAX: 415-528-2812
HF 4, 8, 10 & 14
>'. l l - ,
I t
_ MX I"
^rM1
WATZR INUT *STRAINER f STOLFEMALE PIPE THIl
TjL- ^ ] SLIP JUINJ l f J lONNIXTION
I L ATitt si r m
FRONT VIEW RK.HT MDL VILW
|V ^
Wall HungHW8 & 14
3 HEJCHTADULTS 40* 11016tV^UNCSTERS
siSjty fLOOR UNE\ . t ,,
< ',
HSF 14Children Heights
FRONT PANELHOLDINt. St KIW\
DRAIN PI f tI iv,(i.n
SLIPIOIN) CONNECTION
A T M'PPD
f DRAIN TRAP
(NOT FURNIMtED)
RICHT D E VIEW
Compact Wall HungHWS 4, 8 & 13
RECOMMENDED HEICHTADULTS *0 'T 410291YDUNCSTEBS ) ] ' { - | l lFROM FLOOR LINE
HANCERBRACKET
WATER INLET STRAINER /; STDiFEMALE PIPE THD
WASTE OUTLET
WATER SUfPLY
-AIR LUUVERSMITH SIDESMOUNTING FRONT fANEL TCLIPS HOLO1NC SCREWS _^
2
ELECTRIC OUTLET |5H1NOT FURNISHED!
I. HOLES. 1 EA END"(1DIA.
FHONT VIEWRtCHT SIDE VIEU
- HANCER BRACKET
DRAIN PIPE
SUP IOINTCONNECTION
WATER SUPPLY LINE
DRAIN TRA?s(N0TFURNI$HED1
SHUTOFF VALVE
A1TERNATE LOCATIONFOR DRAJN TRAP AND
WATER sur rut UNE
Flush to WallExplosion Proof
HFX16W
I1KA1N PIPE',7 O.DSLIP IOINTCONNECTION
WATER SUPPLY
DRAIN TRAP(NOT FURNISHED!SHUT(IFF VALVE
RIGHT SIDE VIEW
HAWS Water Cooler Owners ManualINSTALLER PLEASE LEAVE WITH COOLER
This manual provides installation, maintenance and trouble shootingguide for the following basic water cooler models:
HF-4, -8, -10, -14 * HWS-4, -8 & 13HW-8, -14 HFX16W
READ THESE INSTRUCTIONS BEFORE STARTING INSTALLATION
IMPORTANTI. Safety Precautions
A. Do not allow water to come into contact withlive electrical wires because short circuitingand shocks can occur.
B. WARNING Beware of rotating fans whencovers are removed.
C. Care should be taken not to puncture refrigera-tion system lines. Some lines contain gas underhigh pressure.
D. Install cooler to conform with all applicablecodes, including the National Electrical Code.
H. InstallationA. WATER SUPPLY The water cooler is fitted
with a 3/g F.PT. inlet fitting strainer, as shownon the installation drawings. Connecting linesmust be thoroughly flushed to remove all dirtand debris before connection to the copier.Warranty claims will not be accepted if the inletstrainer, coil or valve are blocked with foreignmatter.These coolers are fitted with a remote connec-tion. (Do not connect supply line to this fittingas.it will allow the inlet water to bypass thecooling coil; therefore not giving cold water atthe bubbler.)
B. DRAIN CONNECTION l1^' I.P.S. - The in-staller must provide a waste trap and install inaccordance to local codes.
C. ELECTRICAL CONNECTIONS 1. Check first to make sure electrical (supply)
voltage is the same as shown on the coolerserialnameplate. If not the same, do not con-nect to the electrical supply because majordamage could result.
2. The water cooler must be protectively grounded.Make sure the supply connection is providedwith a protective grounded wire. Do not usethe cooler if ground wire is not connected.
3. Connect the cooler only by the lead provided.Do not wire direct to the compressor.
D. VENTILATION To maintain proper ventilation.and correct func-
tioning of the water cooler a 4" clearance isrequired on each side of the cooler louvers.Failure to comply could cause the compressorto fail and therefore void the warranty.
E. INSTALLATION OF COOLERThe drawings provided with these instructionsshow the cooler dimensions, location of all therequired services and mounting instructions forthe wall hung models. The installer is respon-sible for providing the drain trap and shut offvalve.
F. CONDENSER FANBefore plugging unit into electrical supply makesure fan rotates freely. Failure to check free fanmovement can cause compressor failure, voidingthe warranty.
G. ADJUSTMENTSThe water flow cartridge and thermostat are setat the factory. Adjustments, if required, shouldbe done in accordance with these instructions(Maintenance] and by a trained technician.
III. MaintenanceA. GENERAL .
Any work carried out inside the cabinet (oncefront panel is rernoved) must be done by aqualified technician who is aware of thehazards.
B. MAINTENANCE1. For appearance and hygiene, it is recommended
that the top and cabinet be cleaned regularlywith a mild cleaning agent.
2. Keep the air flow vents clean and free frompaper, debris and dust to assure good operation
C. WATER FLOW ADJUSTMENTSAccess to the cartridge flow regulator is gainedby removing the front panel. (See drawing pro-vided). The location of the cartridge is in theupper left hand corner of the cabinet. Adjust-ments can be made through the hole providedwith a small screw driver. A clockwise rotationincreases the flow rate. An ideal stream heightis approximately 6" above top of drain receptor.Adjustments to this cartridge are not coveredby the warranty.
D. TEMPERATURE CONTROL THERMOSTATThis control is located inside front panel andis factory set at 45 F. For colder water, adjustthe screw in a clockwise direction.
E. STORAGE OF COOLER If location ofcooler is such that it is subjected to freezingtemperature, care should be taken to complete-ly drain the drinking water storage chamber.Water cooled models must also have the watercondenser coils completely drained.
WARRANTYWarranty certificate provided with the cooler tells what
to do in the unlikely event of a failure of your cooler. Ad-justment to flow ana water temperature are not covered bythe warranty. For detailed information concerning themaintenance and repair of your water cooler,* contact thefactory and request an instruction Manual.
PMX-552 11/85
- 1
MODELS APPLIEDJ
\
COMPONENT
COMPRESSOR
OVERLOAD
RELAY
RELAY/OVERLOADFAN MOTORFAN BLADETHERMOSTATBUBBLER SPOUTCARTRIDGECONDENSERCONDENSERCONDENSERWATER VALVESTRAINER SCREENPUSH BUTTONSPRINGROD DUAL ONLYDRAIN WASHEREVAPORATORHOT TANK ASSYHOT THERMOSTATHOT TANK O/LHOT VALVEHOT TANK SWITCH
PART NO.
A019055A019703A019840A018265A019065A019705A019841A019064A019706AD 19842AO18606B153475A016338A016241C026018B153468C026102C026101C026104A016492-01A019489A017272-01A016837AO16368AO15671C026072D035704A019285AO19371B153497A019247
HF4
e
e
o
HF8
e
e
HF10
9
e
e
9
e
HF14
o
e
e
e
HW8
o
e
HW14
9
9
9
9
e
HWS4
e
e
HWS8
9
9
9
HWS13
9
HFX16W
) |
I :i i
I i
1 !
0
Ii
i
!
9
9
9
9
e
I
9 !
9
e
9
9
9
e
NOTE: For water cooled models and other parts not shown, contact the factory. (415) 525-5801ISIC TROUBLE SHOOTING1. WATER DRIBBLES OR FLOWS
CONTINUOUSLYA Din in canndge Replace
canndgeB. Mechanism jammed Check
and remove restrictionC. Bad cartridge Replace
2. NO WATER FLOWA Blocked inlet screen Clean or
replaceB. Water supply OFF Turn ONC. Frozen Coils Bad thermostat
or short cycling compressor Call service man.
D. Bad cartridge Replace
3. NOT COOLINGA. Thermostat turned to OFF
position Reset to ONposition
B. Electric supply failure or blownfuse Reenergize or replacefuse.
C. Refrigeration failure Callservice man.