+ All Categories
Home > Documents > Water level measurement Water level sensor: Hydrolog · PDF fileWater level measurement. Water...

Water level measurement Water level sensor: Hydrolog · PDF fileWater level measurement. Water...

Date post: 20-Mar-2018
Category:
Upload: hakhue
View: 227 times
Download: 1 times
Share this document with a friend
4
Specials Order code page |04| Description Water level measurement Water level sensor: Hydrolog ® 3000 ACS-CONTROL-SYSTEM GmbH | Lauterbachstr 57| 84307 Eggenfelden | +49 (0)8721 / 9668-0 | wwwacs-controlsystemde | info@acs-controlsystemde | 1 | Groundwater - data collector with integrated temperature sensor, alarm management, operation and control interval value logging The water level senor with data memory Hydrolog® 3000 is a battery powered system for autonomous measurement of water levels from 1 up to 100m water column and temperatures in liquids, at environmental temperatures from - 25°C to +70°C The preferential application fields are water supply and distribution eg for measurement tubes, control levels, wells, containers and outstanding waters like lakes and rivers The excellent characteristics like highest strength against pressure and pressure blows, high resistance against chemicals and corrosion, very good insensitiveness against temperature shocks and EM interference, highest accuracy and long term stability as well as low influence of temperature makes it possible to use the sensor in various fields with liquids like water, waste water, solvents, oil, sludge, grease, cleaning agents, etc, where levels and temperatures combined with date and time should be surveillanced without having any auxiliary power at the place of installation For applications, where food or drink water suitability is necessary, a corresponding variant can be ordered where only suitable materials are used Because of many possibilities of adjustment a highest flexibility in the application for control level and especially for pumping test or long term surveillance is given High accuracy and long term stable water level measurement Ceramic highly overload resp pressure blow resistive membrane Food- and drinking water suitable materials Integrated temperature measurement Integrated battery for minimum 2 million measurements resp 10 years operation at a measuring interval of 3 minutes Measuring rates from 1x per second up to 1x per 100 days Data memory for up to 216 000 measurement values Interface head up to 3m water column flood protected Installation in water level tubes of 1 ¼”, at wider level tubes, eg 2”, a control plumbing by cable light plumbline is possible without deinstallation Data retrieval directly per PC resp handheld-PC or wireless remote data transmission per GSM/GPRS Application high accuracy 0,1% integrated temperature measuring flood protected battery life time 10 years alarm management robust ceramic sensor
Transcript
Page 1: Water level measurement Water level sensor: Hydrolog · PDF fileWater level measurement. Water level sensor: Hydrolog ... long term stability as well as low ... C 04 m water column

Specials

Order code . . . . . . . . page |04|

Description

Water level measurement Water level sensor:

Hydrolog® 3000

ACS-CONTROL-SYSTEM GmbH | Lauterbachstr . 57| 84307 Eggenfelden | +49 (0)8721 / 9668-0 | www .acs-controlsystem .de | info@acs-controlsystem .de | 1 |

Groundwater - data collector with integratedtemperature sensor, alarm management, operation andcontrol interval value logging

The water level senor with data memory Hydrolog® 3000 is a battery powered system for autonomous measurement of water levels from 1 up to 100m water column and temperatures in liquids, at environmental temperatures from - 25°C to +70°C .

The preferential application fields are water supply and distribution e .g . for measurement tubes, control levels, wells, containers and outstanding waters like lakes and rivers .

The excellent characteristics like highest strength against pressure and pressure blows, high resistance against chemicals and corrosion, very good insensitiveness against temperature shocks and EM interference, highest accuracy and long term stability as well as low influence of temperature makes it possible to use the sensor in various fields with liquids like water, waste water, solvents, oil, sludge, grease, cleaning agents, etc ., where levels and temperatures combined with date and time should be surveillanced without having any auxiliary power at the place of installation .

For applications, where food or drink water suitability is necessary, a corresponding variant can be ordered where only suitable materials are used .

Because of many possibilities of adjustment a highest flexibility in the application for control level and especially for pumping test or long term surveillance is given

• High accuracy and long term stable water level measurement• Ceramic highly overload resp . pressure blow resistive membrane• Food- and drinking water suitable materials• Integrated temperature measurement• Integrated battery for minimum 2 million measurements resp . 10 years operation at a measuring interval of 3 minutes• Measuring rates from 1x per second up to 1x per 100 days• Data memory for up to 216 000 measurement values• Interface head up to 3m water column flood protected• Installation in water level tubes of 1 ¼”, at wider level tubes, e .g . 2”, a control plumbing by cable light plumbline is possible without deinstallation• Data retrieval directly per PC resp . handheld-PC or wireless remote data transmission per GSM/GPRS

Application

highaccuracy

0,1%

integratedtemperature measuring

flood

protected

batterylife time

10 years

alarmmanagement

robust

ceramic sensor

Page 2: Water level measurement Water level sensor: Hydrolog · PDF fileWater level measurement. Water level sensor: Hydrolog ... long term stability as well as low ... C 04 m water column

Technical data

| 2 | ACS-CONTROL-SYSTEM GmbH | Lauterbachstr . 57| 84307 Eggenfelden | +49 (0)8721 / 9668-0 | www .acs-controlsystem .de | info@acs-controlsystem .de

Power supply

Power supply: integrated lithium battery

Battery life: ≥ 2.000.000 measurement resp. ≥ 10 years with a measuring interval of 1x per 3 minutes

Accuracylevel Range: 1 m water column up to 100 m water column

Units: mWs / cmWs / bar / mbar / mNN / mlowering

Deviation: ≤ 0,1% resp. 0,25% FS

Measuring range temperature: -25°C . . . +70°C

Accuracy: ≤ 0,3 Kelvin

Data storage

Memory capacity: 128 kB: 21 .600 . . . 216 .000 records (water level) 16 .200 . . . 162 .000 records (water level / temperature)

Measurement Range: one measurement per 1 second to one measurement per 100 days

MaterialsMembrane: ceramic AL2O3 96% (medium contact)

Probe: Steel1 .4404 (AISI 316L) / 1 .4571 (AISI 316Ti) (medium contact)

Read-out unit: CrNi-Steel

Extension cable: PE Polyethylen (medium contact)

Seals: FPM – fluorelastomer (Viton®), EPDM – Etylen-ethylene- propylene - diene monomer (medium contact)

Environmental conditionsAmbient temperature: – 25°C . . .+70°C, ice-free

medium temperatures: – 25°C . . .+70°C, ice-free

measurement Range: 0 . . .1 mWs up to 0 . . .100 mWs

In use

Page 3: Water level measurement Water level sensor: Hydrolog · PDF fileWater level measurement. Water level sensor: Hydrolog ... long term stability as well as low ... C 04 m water column

Dimension drawingsWater level sensor:

Hydrolog® 3000

ACS-CONTROL-SYSTEM GmbH | Lauterbachstr . 57| 84307 Eggenfelden | +49 (0)8721 / 9668-0 | www .acs-controlsystem .de | info@acs-controlsystem .de | 3 |

Page 4: Water level measurement Water level sensor: Hydrolog · PDF fileWater level measurement. Water level sensor: Hydrolog ... long term stability as well as low ... C 04 m water column

Order code

| 4 | ACS-CONTROL-SYSTEM GmbH | Lauterbachstr . 57| 84307 Eggenfelden | +49 (0)8721 / 9668-0 | www .acs-controlsystem .de | info@acs-controlsystem .de

Sta

nd 0

1/20

18

Type0 Standard T Certificate for food and drink water suitability of all liquid contacting materials

Process connection 14 Mounting into 1 ¼” water level tube, control measurement without removal not possible 12 Mounting into 1 ½” water level tube, control measurement without removal not possible 20 Mounting into 2” water level tube, control measurement without removal possible

Measuring signals S Water level T Water level and temperature

Accuracy meas. System – material meas. Membrane (medium contact) 0 ceramic 96%, 0,25% K ceramic 96%, linearization protocol 0,1%

Measuring range (in mwc) A 0…1 m water column B 0…2 m water column C 0…4 m water column M 0…5 m water column D 0…6 m water column E 0…10 m water column F 0…20 m water column G 0…40 m water column J 0…50 m water column H 0…100 m water column Y Special measuring range

Memory capacity 1 max . 216 000 data records, water level max . 162 000 data records, water level and temperature

1

Material sensor (medium contact) 1 Steel 1 .4404 (AISI 316L) / 1 .4571 (AISI 316 Ti)

Material gaskets (medium contact) 1 FPM, fluorelastomere (Viton®) 3 EPDM, etylene-propylene-dienmonomere

Material carrying cable (price per started 100 mm) A PE polyethylene

Probe length in mm

Order code

Hydrolog® 3000 mm11 1 A


Recommended