+ All Categories
Home > Documents > WCAP-17639-NP, Revision 3, 'Instrumentation Description ...1 Revised in accordance with customer...

WCAP-17639-NP, Revision 3, 'Instrumentation Description ...1 Revised in accordance with customer...

Date post: 16-Oct-2020
Category:
Upload: others
View: 0 times
Download: 0 times
Share this document with a friend
15
Attachment 11 Peach Bottom Atomic Power Station Units 2 and 3 NRC Docket Nos. 50-277 and 50-278 WCAP-17639, Rev 3. Instrumentation Description for the Peach Bottom Unit 2 Replacement Steam Dryer
Transcript
Page 1: WCAP-17639-NP, Revision 3, 'Instrumentation Description ...1 Revised in accordance with customer audit. Due to the extent of revisions, change bars 8/27/2012 are not used. 2 Revised

Attachment 11

Peach Bottom Atomic Power Station Units 2 and 3

NRC Docket Nos. 50-277 and 50-278

WCAP-17639, Rev 3. Instrumentation Description for the Peach Bottom Unit 2Replacement Steam Dryer

Page 2: WCAP-17639-NP, Revision 3, 'Instrumentation Description ...1 Revised in accordance with customer audit. Due to the extent of revisions, change bars 8/27/2012 are not used. 2 Revised

Westinghouse Non-Proprietary Class 3

WCAP-17639-NP FebrRevision 3Enclosure B.7

Instrumentation Descriptionfor the Peach Bottom Unit 2Replacement Steam Dryer

) Westinghouse

uary 2014

Page 3: WCAP-17639-NP, Revision 3, 'Instrumentation Description ...1 Revised in accordance with customer audit. Due to the extent of revisions, change bars 8/27/2012 are not used. 2 Revised

WESTINGHOUSE NON-PROPRIETARY CLASS 3

WCAP-17639-NPRevision 3

Instrumentation Description forthe Peach Bottom Unit 2Replacement Steam Dryer

Author

Kristen Kahsar*

Reviewed by

David A. Suddaby*

February 2014

Approved: David R. Forsyth*, ManagerBWR Plant & Stress Analysis

*Electronically approved records are authenticated in the electronic document management system.

Westinghouse Electric Company LLC1000 Westinghouse Drive

Cranberry Township, PA 16066, USA

© 2014 Westinghouse Electric Company LLCAll Rights Reserved

Page 4: WCAP-17639-NP, Revision 3, 'Instrumentation Description ...1 Revised in accordance with customer audit. Due to the extent of revisions, change bars 8/27/2012 are not used. 2 Revised

WESTINGHOUSE NON-PROPRIETARY CLASS 3 ii

RECORD OF REVISIONS

Revision Description Completed

0 Original issue 08/17/2012

1 Revised in accordance with customer audit. Due to the extent of revisions, change bars 8/27/2012are not used.

2 Revised in accordance with customer audit. Due to the extent of revisions, change bars 9/25/2012are not used.

3 Revised to incorporate details on new instruments and additional pressure transducer See EDMSlocations.

WCAP- 1 7639-NPRevision 3

February 2014

Page 5: WCAP-17639-NP, Revision 3, 'Instrumentation Description ...1 Revised in accordance with customer audit. Due to the extent of revisions, change bars 8/27/2012 are not used. 2 Revised

WESTINGHOUSE NON-PROPRIETARY CLASS 3 iii

TABLE OF CONTENTS

R E C O R D O F RE V ISIO N S .......................................................................................................................... ii

L IST O F TA B L E S ....................................................................................................................................... iv

L IST O F F IG U R E S ...................................................................................................................................... V

L IST O F A C R O N Y M S ................................................................................................................................ vi

1 IN T R O D U C T IO N ........................................................................................................................ 1-12 INSTRUMENTATION OVERVIEW ........................................................................................... 2-13 DATA ACQUISITION AND REDUCTION SYSTEM ................................................................ 3-1

3.1 INSTRUMENT SPECIFICATIONS ................................................................................ 3-13.2 INSTRUMENT POSITIONS .......................................................................................... 3-13.3 ENSURING ACQUISITION OF QUALITY DATA ....................................................... 3-33.4 ONLINE DATA EVALUATION SYSTEM ..................................................................... 3-33.5 DETERMINING FREQUENCY, MODAL CONTENT, AND MAXIMUM VALUES. 3-43.6 BIAS ERRORS AND RANDOM UNCERTAINTIES .................................................... 3-4

4 REFERENCES ............................................................................................................................. 4-1

WCAP- 17639-NPRevision 3

February 2014

Page 6: WCAP-17639-NP, Revision 3, 'Instrumentation Description ...1 Revised in accordance with customer audit. Due to the extent of revisions, change bars 8/27/2012 are not used. 2 Revised

WESTINGHOUSE NON-PROPRIETARY CLASS 3 iv

LIST OF TABLES

T ab le 3-1 ]a,c ................................................................................. 3-1

WCAP- 17639-NPRevision 3

February 2014

Page 7: WCAP-17639-NP, Revision 3, 'Instrumentation Description ...1 Revised in accordance with customer audit. Due to the extent of revisions, change bars 8/27/2012 are not used. 2 Revised

WESTINGHOUSE NON-PROPRIETARY CLASS 3 v

LIST OF FIGURES

F igure I-1 [ ]a,c ............................................................... 1-1

WCAP- 17639-NPRevision 3

February 2014

Page 8: WCAP-17639-NP, Revision 3, 'Instrumentation Description ...1 Revised in accordance with customer audit. Due to the extent of revisions, change bars 8/27/2012 are not used. 2 Revised

WESTINGHOUSE NON-PROPRIETARY CLASS 3 viWESTINGHOUSE NON-PROPRIETARY CLASS 3 vi

LIST OF ACRONYMS

AcronymDASNRC

OEMRAI

Definitiondata acquisition systemU.S. Nuclear Regulatory Commissionoriginal equipment manufacturerrequest for additional information

Trademark Note:

INCONEL is a registered trademark of the Special Metals Corporation group of companies.

WCAP- 1 7639-NPRevision 3

February 2014

Page 9: WCAP-17639-NP, Revision 3, 'Instrumentation Description ...1 Revised in accordance with customer audit. Due to the extent of revisions, change bars 8/27/2012 are not used. 2 Revised

WESTINGHOUSE NON-PROPRIETARY CLASS 3 1-1

1 INTRODUCTION

Exelon is replacing the original equipment manufacturer (OEM) steam dryers at its Peach Bottom site.The Peach Bottom site has two reactors numbered Unit 2 and Unit 3 that will have their steam dryersreplaced with Westinghouse-designed steam dryers.

This document describes the instrumentation to be installed on the Peach Bottom Unit 2 replacementsteam dryer (shown in Figure 1-1). This dryer will be the first of the two installed. The Peach Bottom Unit2 steam dryer will be considered a "Prototype" design consistent with the U.S. Nuclear RegulatoryCommision (NRC) document Regulatory Guide 1.20, "Comprehensive Vibration Assessment Program forReactor Internals During Preoperational and Initial Startup Testing" (Reference 1).

]a,c

a,c

Figure 1-1 [ Ia,C

WCAP-17639-NPRevision 3

February 2014

Page 10: WCAP-17639-NP, Revision 3, 'Instrumentation Description ...1 Revised in accordance with customer audit. Due to the extent of revisions, change bars 8/27/2012 are not used. 2 Revised

WESTINGHOUSE NON-PROPRIETARY CLASS 3 2-1

2 INSTRUMENTATION OVERVIEW

I

WCAP- 17639-NPRevision 3

February 2014

Page 11: WCAP-17639-NP, Revision 3, 'Instrumentation Description ...1 Revised in accordance with customer audit. Due to the extent of revisions, change bars 8/27/2012 are not used. 2 Revised

WESTINGHOUSE NON-PROPRIETARY CLASS 3 3-1

3 DATA ACQUISITION AND REDUCTION SYSTEM

Sections 3.1 through 3.6 address subitems (a) through (f) of Section 2.2, item 1, in Regulatory Guide 1.20(Reference 1). The material is limited to description of direct steam dryer instrumentation.

3.1 INSTRUMENT SPECIFICATIONS

Consistent with the guidance contained in RG 1.20 (Reference 1), this section describes theaccelerometer, pressure transducer, and strain gauge being used to instrument the steam dryer. Table 3-1summarizes the instruments.

Table 3-1 [ ]a,c

I

]a.b,c

[ ]ab,.c

3.2 INSTRUMENT POSITIONS

Regulatory Guide 1.20 requests details on the "transducer positions, which should be sufficient to monitor

significant lateral, vertical, and torsional structural motions of major reactor internals components in shell,beam, and rigid body modes of vibration, as well as significant hydraulic responses and those parametersthat can be used to confirm the input forcing function" (Reference 1). This section describes the criteria

WCAP-17639-NPRevision 3

February 2014

Page 12: WCAP-17639-NP, Revision 3, 'Instrumentation Description ...1 Revised in accordance with customer audit. Due to the extent of revisions, change bars 8/27/2012 are not used. 2 Revised

WESTINGHOUSE NON-PROPRIETARY CLASS 3 3-2

used to identify locations for the accelerometers, pressure transducers, and strain gauges installed on thesteam dryer.

a,c

WCAP- 17639-NP February 2014Revision 3

Page 13: WCAP-17639-NP, Revision 3, 'Instrumentation Description ...1 Revised in accordance with customer audit. Due to the extent of revisions, change bars 8/27/2012 are not used. 2 Revised

WESTINGHOUSE NON-PROPRIETARY CLASS 3 3-3

]a~c

3.3 ENSURING ACQUISITION OF QUALITY DATA

Regulatory Guide 1.20 requests details on the "precautions being taken to ensure acquisition of qualitydata (e.g., optimization of signal-to-noise ratio, relationship of recording times to data reductionrequirements, choice of instrumentation system)" (Reference 1).

]a.c

3.4 ONLINE DATA EVALUATION SYSTEM

Regulatory Guide 1.20 requests details on the "online data evaluation system to provide immediateverification of general data quality" (Reference 1).

WCAP- 17639-NPRevision 3

February 2014

Page 14: WCAP-17639-NP, Revision 3, 'Instrumentation Description ...1 Revised in accordance with customer audit. Due to the extent of revisions, change bars 8/27/2012 are not used. 2 Revised

WESTINGHOUSE NON-PROPRIETARY CLASS 3 3-4

ia,b,c

3.5 DETERMINING FREQUENCY, MODAL CONTENT, AND MAXIMUM VALUES

Regulatory Guide 1.20 requests details on the "procedures for determining frequency, modal content, andmaximum values of response" (Reference 1).

[]a~c

3.6 BIAS ERRORS AND RANDOM UNCERTAINTIES

Regulatory Guide 1.20 requests details on "all bias errors (such as model underprediction) and random

uncertainties (such as instrumentation error) associated with the instrumentation and data acquisition

systems" (Reference 1).

[

]a,

WCAP- 1 7639-NPRevision 3

February 2014

Page 15: WCAP-17639-NP, Revision 3, 'Instrumentation Description ...1 Revised in accordance with customer audit. Due to the extent of revisions, change bars 8/27/2012 are not used. 2 Revised

WESTINGHOUSE NON-PROPRIETARY CLASS 3 4-1

4 REFERENCES

1. U.S. Nuclear Regulatory Commission, Regulatory Guide 1.20, Revision 3, "ComprehensiveVibration Assessment Program for Reactor Internals During Preoperational and Initial StartupTesting," March 2007.

2. Deleted.

3. WCAP-17609-P, Revision 2, "Peach Bottom Units 2 and 3 Replacement Steam Dryer StructuralEvaluation for High-Cycle Acoustic Loads," February 2014. (Westinghouse Proprietary Class 2)

WCAP- 17639-NPRevision 3

February 2014


Recommended